mv V

3.

Wisconsin n

~

1 Electnc; wOWER COMPANY f7 23' W MicNgort Po Box 2046, Mdwoukee W153201 14.4)221 2345

.VPNPD-92-246

.NRC-92-075

-July 10, 1992

.U.

(1. NUCLEAR REGULATORY COMMISSION Document Control Desk I

' Mail' Station'P1-137.

Washington, D..C.

20555 Gentlemen:

DOCKETS 50-266 AND 50-301 1

REOUEST FOR REVIEW OF WCAP-13360

" WESTINGHOUSE DYNAMIC ROD WORTH 9 MEASUREMENT TECHNIOUE"'

POINT BEACH NUCLEAR PLANT. UNITS 1 AND 2

~

Representatives.of Westinghouse Electric and Wisconsin Electric j

Power Company met with'NRR staff. members on April 28, 1992, to

discuss:the dynamic rod worth measurement technique developed by 4

4

' Westinghouse.

As. agreed upon in that meeting,. Westinghouse j

submitted-this technique-to the-NRC for review and approval in WCAP-513360,E" Westinghouse Dynamic Rod Worth Measurement Technique."

The i

.purposeiof.this letterris to confirm our desire to use this technique'in theLevaluation of rod worths.during this fall's Unit 2 start-upffollowing its' annual refueling-outage and in other subsequent start-ups at Point Deach Nuclear Plant.

y

~

EThe, dynamic rod worth measurement: technique was demonstrated (successfully at' Point Beach in November 1991 during stact-up l

following our. Unit 2 refueling outage. - The: results of this L

dem7nstration~ indicate that'the dynamic rod worth technique measures q

rod worths to..the same degree of accuracy as our. current rod bank

exchange measurements. =The dynamic rod worth measurement technique

. proved to~be a-simple method for determining the integral rod worth Lof1each-bank without the effects of otner banks in the core.

We =

have found that:thefexclusive use of the dynamic rod worth f

~measurementetechnique will save approximately'eight_ hours of critical' path: time and the water processing costs associated with Lthe rod ~ swap method.

This measurement technique will also allow us g

- toidetermine rod: worth while changing reactivity by only one method.

\\

T70~f.u+3a-

  1. h\\I b

'9207170253 920710

-PDR ADOCK 05000266

(

.P PDR ilsubs&qof%vauhEneqyCorpntwo

p

NRC., Resident Inspector

' Jtily 10, 1992 Page 2 l

We request NRC review and acceptance of WCAP-13360 by November 1, 1992, so that we may use this technique to. measure rod worths during start-up following our scheduled fall 1992 Unit 2 refueling outage.

Please contact us if you have any questions.

-Sincerely,

./

/

Bob-Link Vice President Nuclear Pcwer Copies to NRC Regional Administrator, Region III NRC Resident Inspector s

l-I L

t

-