Text
DM 1$
. ['N Commonwmith Edison C
) one First National Plaza, Chicago. lilinois (O
Address Reply to: Post Office Box 767 Chicago, lilinois 60690 4
January 25, 1985 Mr. James G. Keppler Regional Administrator U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137
Subject:
LaSalle County Station Units 1 and 2 Response to Inspection Report Nos.
50-373/84-31 and 50-374/84-38 NRC Docket Nos. 50-373 and 50-374 Reference (a):-
C. J. Paperiello letter to Cordell Reed dated December
Dear Mr. Keppler:
This letter is in response to the inspection conducted by Mr. D. E. Miller on November 26-29 and December 3-4, 1984, of activities at LaSalle County Station.
Reference (a) indicated that certain activities appeared to be in noncompliance with NRC requirements.
The Commonwealth Edison Company response to the Notice of Violation is-provided in the enclosure.
If you have any further questions on this matter,_please direct them to this office.
Very uly yours, p
x ; Q:seu D.
L. Farrar Director of Nuclear Licensing 1m t
Attachment cc:
NRC Resident Inspector - LSCS 1 1 850' 050545 850125
$k 29 $g 2
9678N-hDRADOCK05000g c
J
.;f *yy ~
. v ATTACHMENT RESPONSE-TO-NOTICE OF VIOLATION
' ITEM-OF? NONCOMPLIANCE iTechnical. Specification'3.3.7.10 states that the radioactive: liquid monitoring instrumentation channels shown in
. T a b l e. 3.~ 3. 7 ; 1 0 - 1, shall be operable with their alarm / trip setpoints
. set-to_ ensure'that the limits of specification 3.11.1.1 are not
-exceeded.
Action statement 3.3.7.10.a states that with a radioactive
-liquid effluent monitoring instrumentation channel alarm / trip
- setpoint.less conservative than required, immediately suspend the
~
release of radioactive -liquid effluents monitored by the affected channel.or declare..the channel' inoperable.
Contrary to-the above on August 23, 1984, a radioactive liquid effluent release was made from a discharge tank with a nonconservative> alarm / trip setpoint.
CORRECTIVE-ACTION TAKEN-AND' RESULTS ACHIEVED No immediate corrective action was taken, since the error
-was'not recognized until a.second similar occurence on September 27, 1984:was1 discovered;for batch 45-84.
(Reference LER #84-086-00)
'A review of the Offsite Dose Calculation Manual (ODCM)_.
i
? calculations :for Bg{ch 44-84J reveals a dose to ag individuals 'whole
'bodyLof 1.53 x110-
~mR and:a' dose of 8.64 x 10-mR to the
- -internal organs, which are less than the Technica1' Specification
~ limits.
Therefore,)the effect'on the-health and safety of the
.gener'al publiclwas negligible.,
i m
CORRECTIVE ACTION TAKEN T0-' AVOID FURTHER NONCOMPLIANCE-LCP'140-7, Analysis'of Radwaste Discharge Tanks-1(2)WF05T=
y and Determination;of' Discharge Flow. Rate Using Cooling' Pond, iBlowdown, is being revised with an' additional attachment'for the 1
N hift: Engineer to complete, relative to'the determination of
' iradwaste: effluent liquid process radiation monitor high alarm / trip setpoint. nThis williprovide :more. definitive ~ control of setpoint
< changes s
DATE;0F'FULLICOMPLIANCEi LFull compliance.has'been achieved.'
.~-
'9678N=
--c
'