ML20101M938

From kanterella
Jump to navigation Jump to search
Responds to Violations Noted in Emergency Preparedness Appraisal Rept 50-382/83-08.Corrective Actions:Operator walk-throughs of Radiation Monitoring Sys Completed 840830
ML20101M938
Person / Time
Site: Waterford Entergy icon.png
Issue date: 09/06/1984
From: Cook K
LOUISIANA POWER & LIGHT CO.
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20101M896 List:
References
W3F84-0151, W3F84-151, NUDOCS 8501030298
Download: ML20101M938 (1)


Text

_ _ _ _

J.

IP LOUISIANA

[ P O W E R & L i G H T! P O oOX 6000

  • NEW OnLEANS 442 oE u noNot s1n a r

. (5041 366 2345 UTIUTIES StSTEM September 6, 1984 W3F84-0151 3-A45 Mr. J.T. Collins Regional Administrator U.S. Nuclear Regulatory Commission

{@]Q@)

Region IV 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011

(

W IOM

SUBJECT:

Louisiana Power & Light Company Waterford 3 SES j

NRC Finding 8308-118

REFERENCE:

Telecon on July 25, 1984 between Paul Backes and Charles Hackney

Dear Mr. Collins:

This letter addresses the August 24, 1984 completion date for the NRC emergency preparedness appraisal finding item 8308-118, operator walk-throughs of the Radiation Monitoring System. The walk-throughs have been completed for all operators. The walk-throughs were completed prior to August 24, 1984 with the exception of one operator who, due to an unavoidable conflict between the training schedule and his vacation, did not complete the training until August 30, 1984.

Very truly yours, f

'O i

K.W. Cook Nuclear Support & Licensing Manager KWC/ASL/mim cc:

W.H. Stevenson, E.L. Blake, B. Churchill, L. Constable 0501030290 041219 PDR ADOCK 05000302 O

VDit L-J