. dN%

gj*/

STATE OF lLLINOIS DEPARTMENT OF NUCLEAR SAFETY 1035 OU(ER PARK DRIVE SPRINGFIELD,IL 62704 (217)785 9900 TnouAs W. ORTCIGER Jiu EtcAR Dnec e cavmn Dr. Thomas E. Murley, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555 Attn: Document CcM rol Desk

Subject:

Byron /Braidwood Application for Amendment to facility Operating License NPF-37, NPF-66, NPF-72, and NPf-77 In Response Please Refer to 91-39

Dear Dr. Murley:

Pursuant to 10 CFR 50.91, the 111 90is Department of Nuclear Safety (IDNS) hereby submits final comments to the proposed license amendment by Commonwealth Edison dealing with surveillance requirements for venting Emergency Core Cooling System discharge lines at Byron and braidwood.

The attached report concludes that the transient analyzed presents safety significant conditions that were not analyzed by the licensee. IDNS recommends, therefore, that NRC consider this analysis in their "no significant hazards" determination.

. ely,7

/[frankN)iiofek Sin

,, p ,

,. x/ k _

Reacto tSifety Section Head FN:ec

Attachment:

Byron /Braidwood Unit 1 RHR/S1 Piping Water Hammer Acoustic Ana. lysis uw y< %%f

""** $0 SDo!! $ O00!s4 P PDR

, . . . _ _ - _ _ _ _ _ _ _ ___