g WF#LF CREEK NUCLEAR OPERATING CORPORATION Otto L Maynard -

Vice Presioent Plant operations March 13, 1996 WO 96-0042 U.

S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station P1-137 Washington, D.'C.

Subject:

Docket 50-482: Special Report 96-001 - Steam Generator Tube Plugging Report Gentlemen This letter provides information regarding the number of tubes plugged in each steam generator as required by Wolf Creek Generating Station Technical Specification 4.4.5.5.

This technical specificat1on requires, in part, that the number of tubes plugged in each steam generator be reported to the Nuclear Regulatory Commission within 15 days following - the completion of each j

inservice inspection of the steam generator tubes.

-The inservice inspection of Steam Generators."B" and "C"

was completed March 5, 1996.

This inservice inspection resulted in mechanical plugging of 12 tubes in Steam Generator "B"

and four tubes in Steam Generator "C."

Mechanical plugging was necessary because of indications-of anti-vibration,bar wear.found during the inservice inspection.

l If you have any questions concerning this matter, - please contact me at (316) 364-8831 extension 4450, or Mr. Richard D. Flannigan at extension 4500.

Very truly yours 190013 Y

  • /

Otto L. Maynard OLM/jra cc:

L. J. Callan (NRC)

W. D. Johnson (NRC)

-J.

F. Ringwald (NRC)

J. C. Stone (NRC) 9603200179 960313 PDR ADOCK 05000482

/

G PDR f ()g PO. Box 411/ Burlington, KS 66839 / Phone: (316) 364-8831 An Equa! Opportunity Employer M/F/HC/ VET

-