ML20101C262
| ML20101C262 | |
| Person / Time | |
|---|---|
| Site: | Beaver Valley |
| Issue date: | 12/18/1984 |
| From: | Woolever E DUQUESNE LIGHT CO. |
| To: | Knighton G Office of Nuclear Reactor Regulation |
| References | |
| 2NRC-4-209, NUDOCS 8412210013 | |
| Download: ML20101C262 (6) | |
Text
'
4 2NRC-4-209 Telecopy 4 8 26 Nuclear Construction Division December 18, 1984 Robinson Plaza, Building 2, Suite 210 Pittsburgh, PA 15205 United States Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:
Mr. George W. Knighton, Chief Licensing Branch 3 Of fice of Nuclear Reactor Regulation
SUBJECT:
Beaver Valley Power Station - Unit No. 2 Docket No. 50-412 Additional Information on Draf t Safety Evaluation Report Outstanding Issue 153 (Fuel Grid Analysis Combined LOCA and Seismic Loads)
Gentlemen:
In letter 2NRC-4-141 of September 11, 1984, Duquesne Light Company (DLC) stated that analysis was in progress to provide the information needed to resolve this issue.
Letter 2NRC-4-203 of December 10, 1984, tr ansmit ted additional informat ion in support of this issue.
This letter transmits the revised FSAR pages which will be incorporated into the next FS AR amendme nt.
This completes the DLC response on this issue.
DUQUESNE LIGHT COMPANY By E. V. Woolever Vice President KAT/wjs Attachment Mr. B. K. Singh, Project Manager (w/a) cc:
Mr. G. Walton, NRC Resident Inspector (w/a)
SUBS RIBED AND SWORN TO EFORE ME THIS
/g DAY OF Mm
,c,
, 1984.
M / /!u w b h Notary Public ANITA ELAINE REITER, NOTARY PUBUC ROBINSON TOWNSHIP, ALLEGHENY COUNTY -
8412210013 841218 MY COMMISSION EXPIRES OCTOBER 20,1986 PDR ADOCK 05000412 E.
PDR 1 I
E
^
Unitsd StcteoL NuclSar R3gulctory Conunicsion Mr..Grorga W. Knighton, Chief Page 2
. COMMONWEALTH'0F PENNSYLVANIA
~)
~
)
SS:
COUNTY OF AL1EGHENY
)
On this.
/
day of
/97[
, before me, a Notary Public in ' and for said Commonwealth and County, personally appeared E. J.. Woolever, who being duly sworn, deposed and said that (1) he is Vice President of Duquesne Light, (2) he is duly authorized to execute and file the foregoing Submittal 'on behalf of said Company, and - (3) the statements set forth in the Submittal are true and correct to the best of his knowledge.
I Notary Public ANITA ELAINE REITER, NOTARY PUBLIC ROBINSON TOWNSHIP, ALLEGHENY COUNTY MY COMMISSION EXPlRES OCTOBER 20,1936 i
+
r i
l
I BVPS-2 FSAR 4.2.3.4 Spacer Grids The reactor coolant flow channels are established and maintained by the structure composed of grids and guide thimbles. The lateral spacing between fuel rods is provided and controlled by 'he support dimples of-adjacent grid t
cells. Contact of the fuel rods on the dimples is maintained through the clamping force of the grid springs. Lateral motion of the fuel rods is opposed by the spring force and the internal moments generated between the spring and the support dimples.
Time history numerical integration techniques are used to analyr.a the fuel assembly responses resulting from the lateral safe shutdown earthquake, SSE, and the most limiting main coolant pipe break accident, LOCA. The reactor vessel motions resulting from the transient loading are asyneetric with respect to the geometrical center of the reactor core. The complete fuel assembly core finite element model is employed to determine the fuel assembly I
deflections and grid impact forces.
A comparison of the seismic (SSE) response spectrum at the reactor vessel supports versus the response spectrum of the time history indicates that the time history spectrum conservatively bounds the design acceleratian spectrum curves for Beaver Valley Unit 2.
The seismic analyses performed for a number of plants indicate that the maximum impact response is, in general, influnced by the acceleration level of the input forcing function at the fuel assembly fundamental mode. Thus, the data in seismic time histories corresponding to the design envelope are conservatively used for the fuel evaluation.
t The reactor et re finite element model consisting of the maximum number of fuel assemblies actoss the core diameter was used. The Beaver Valley Unit 2 Plant has fif teen (15) 17x17 8-grid (Inconel) fuel assemblies arranged in a planar l
array. Gapped elements simulate the clearances between the peripheral fuel assemblies and the baffle plates.
l The fuel assembly finite element model preserves essential dynamic properties, such as the fuel assembly vibration frequencies, mode shapes, and mass i
I l
80350:10/110884
- - w m-w-
-n-,
--ner,7<,,m,-w-----py-a,--wm,~,n-,-,-,,w_,,_,,_-mw.,an--.-.-,m..--,-,~,,,-.n-_-e--,-,--,.m---- - -,, - - - - - - - - - -, - - - - - - - - - - -
BVPS-2 FSAR distribution. The time histor;' motions for the upper and lower core plates and the motions for the core berrel at the upper core plate elevation are simultaneously introduced into the simulated core model. Tne analytical procedures, the fuel assembly and core modeling, and the methodology are detailed in WCAPS 8236 (P), 8288 (NP), 9401 (P) and 9402 (NP). The time history inputs representing the safe shutdown earthquake notions and the coolant pipe rupture transients were obtained from the time history analyses i
of the reactor vessel internals.
GRIO ANALYSIS With respect to the guidelines of Appendix A of SRP Section 4.2, Westinghouse, i
has demonstrated that a simultaneous SSE and LOCA event is highly unlikely.
The fatigue cycles, crack initiation and crack growth due to normal operating and seismic events will not realistically lead to a pipe rupture (WCAP 9283).
The factor applied to the LOCA grid impact load due to flashing has been demonstrated by Westinghouse to be unrealistic for Westinghouse fuel in 1
Westinghouse plants. Therefore, this factor was not applied to the Beaver Valley Unit 2 analysis results.
l The maximum grid impact forces for both the seismic and asymmetric LOCA accidents occur at the peripheral fuel assembly locations adjacent to the i
baffle wall. The maximum grid impact force for the safe shutdown earthquake analysis was 97 percent of the allowable grid strength. The corresponding value for the nozzle inlet break was 37 percent.
In order to comply with the requirements in the USNRC 4.2 Standard Review Plan, the maximum grid impact l
responses obtained from the two transient analyses are combined. The square-root-of-sum-of-squares (SRSS) method is used to calculated the results. The maximum combined impact force for the Beaver Valley Unit 2 fuel assemblies was 99 percent of the allowable grid strength. The grid strength was established experimentally.
It was based on the 95% confidence level on the true mean as taken from the distribution of measurements.
l 9035Q:10/110884
BVPS-2 FSAR Non-Grid Compone.;t Analyses The stresses induced in the various fuel assembly non-grid components are calculated. The calculations are based on'the maximum responses obtained from the most limiting seismic and LOCA accident conditions. The fuel assembly axial forces resulting from the LOCA accident are the primary sources of stresses in the thimble guide tube and the fuel assembly nozzles. The induced stresses in the fuel rods result from the relative deflections during the hypothetical seismic and LOCA accidents. The stresser, are generally small.
The combined seismic and LOCA induced stresses of the various fuel assembly components presented in Table 4.2-1 are expressed as a percentage of the l
allowable limit. Consequently, the fuel assembly components are structurally,
acceptable under the postulated accident design conditions for Beaver Valley Unit 2.
t l
l l
I I
l l
i 8035Q:10/112084
BVPS-2 FSAR TABLE 4.2-1 FUEL ASSEMBLY COMPONENT STRESSES (PERCENT OF ALLOWABLE)
Component Uniform Stresses Combined Stresses (Direct /Membr:r.)
(Membrane + Bending) f Thimble 78.6 64.2 Fuel Rod
- 23.7 20.5 I
6.0 Top Nozzle Plate Bottom Nozzle Plate 47.5 Bottom Nozzle Leg 7.7 8.9 Including primary operating stresses a negligible value l~
l 4
80350:10/110784
-.. - - -. _. _. - _,. - _. _ _ _ _ _ _ _ _ _ _ _ _ _ _. _ _.. _ _ _. _ _ _ _ _. _. _. _.. _ _