3-

,s nocKnLD

\\

D ggij 27 YG4 '

- (^

STRAIN READINGS Als CALCULATED S EO

/

FOR THE COMPLETE STUD BOSS NDSETTES AT 1600 PSIG WIM /'/g77[' '

CONVENTIONAL CROWN (all strain values are in utn/in) i l

C D

E F

H e

-1740

.-1668

-1722

-1605

-1583 g

e 270 366 304 270 246 c

c45

-732

-787

-815

-602

-632 cg 270 375 310 272 247 cgr

-1740

-1677

-1728

-1607

-1584 ogg, ksi

-6.5

-3.3

-5.4

- 5. 5

- 5. 9 oggg, ksi

-43.0

-40.6

-42.4

-39.6

-39.24 O

The reported values are for 1600 psig, dich differs slightly from the effec-tive firing pressure of 1627 psig.

This 1.7% difference in pressure is considered to be negligible.

A e