a-3z2 oc 3.

^

129.

I t

t I thick se take the actual retal Z

dia ens ions.

2 W IT HESS BL AN EIN C s I'm nct sure what th e 4

question is regarding re-en tran t fille t.

5 WITEESS WOYTCWICHs An undercut inte the a

web?

T I think we sculd measure fecm metal tc 8

metal rather than frcm arbitrary line to attittary lin e.

9 0

In that same rule, what is meant by the to ters, the effect of resistico acment of the web in 11 bendin o ?

Can ycu defice that term for us or that 12 phrase ?

13 WITNESS WOYTCWICH The secticn 14 modulus.

Cuctient of moment of inertia of the secticn 15 divided by the distance from the neutral axis to the.

16 outer fiber.

17 MR. STBCUEF:

Makes perfectly gced sense.

18 Q

If ycu take inte account the actual 19 measurement cf the re-enterigg' fillet' in de terminire

  • 5 20 the af f act of moment o f resistance.e,,

5,f?

- i 21 WITNESS WOYTCVICHa# LYtelieve that cur p

,e 22 normal practice Mould be to ' measure tha t' disensien f rom c

i I, ?

l

' l,/p.

y c

4 i

+

8412130294 841001 I

PDR ADOCK 05000322 C

PDR ALDI ASON RIPoRTING COMP ANY. INC.

.............,e

e.

/ [d a

!e <Ik t.fh, /5, g.

en p

,n

/.y Qif

'r e

r

  • i

'*%kt

,% s s, f w

  • g%+

i f l' WO 130 the boundary cf the actual crankshaf t material, at cne t

2 fillet to that at its opposite fillet, rather than 3

ccu stlrcetin g the arbitrary lines cf a face cf the set 4

and going between them.

5 Essentially it makes sense to count caly a

the me tal that is actually there.

T Q

Is the maximum firing pressure value a 8

factor which affects the adequacy cf the crack vets 9

under the ABS rules?

10 WITNESS'WOYTCWICHs Yes.

Because it 11 aff ects the rule required diameter, and the rule fer 12 the crack vets groscrticns the webs acccrding to the 13 crank pin value'.

1' Q

In paragraph 34.17.2, which related tc 15 maximu m firing pressure and EHE, it states the surveyor is is to verify the maximum firing pressure, P, and full IT brake hersercwer during a trial of the engine.

18 Was this done in this case for the TCI 19 submis sion?

20 EIT5ESS GIUFIFAs No, it wasn' t, as far 21 as we are aware.

22 Q

Is it required te be dere?

... J m