7 r -

TABLE 1A - REG GUIDE 1.21 CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT T

FIRST HALF - 1984 GASEOUS EFFLUENTS - SUMM ATION OF ALL RELEASES ist 2nd Est. Total A.

Fission and activation gases Units Quarter Quarter Error, %

l.

Total Release Ci 1.57E+03 8.44E+02 2.15E+01 2.

Average release rate for period uCi/sec 2.00E+02 1.07E+02 3.

Percent of tech. spec. limit (1) 1.17E+00 6.57E-01 4.

Percent of tech. spec. limit (2) 2.53E+00 2.46E+00 B,

Iodines 1.

Total iodine - 131 Ci 1.47E-02 2.26E-02 1.34E+01 2.

Average release rate for period uCi/sec 1.87E-03 2.87E-03 3.

Percent of tech. spec. limit (3) 1.17E+00 1.80E+00 4.

Percent of tech. spec. limit (4) 4.21E+00 4.07E+00 C.

Particulates 1.

Particulates with half lives greater than 8 days Cl 6.64E-06 4.51E-05 1.84E+01 2.

Average release rate for period uCi/sec 8.45E-07 5.74E-06 3.

Percent of tech. spec. limit (3) 5.28E-04 3.59E-03 4.

Percent of tech. spec. limit (4) 2.88E-01 7.70E-03 5.

Gross alpha radioactivity C1

< 2.74E-06

< l.22E-05 D.

Tritium 1.

Total Release C1 4.02E-01 6.09E-01 2.18E+01 2.

Average release rate for period uCl/sec

5. llE-02 7.75E-02 3.

Percent of tech. spec. limit (1) 4.15E-04 6.29E-04 (1) Percent of I.A.2 for each quarter (2) Percent of I.A.3 for previous 12 months (3) Percent of I.B.2 for each quarter (4) Percent of I.B.3 for previous 12 months hkh O

h R

~

TABLE IC REG GUIDE 1.21 (CONT'D)

CALVERT CLIFFS NUCLEAR POWER PLANT FIRST HALF - 1984 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Continuous Mode Batch Mode 1st 2nd ist 2nd 3.

Particulates Units Quarter Quarter Quarter Quarter strontium

- 89 Ci

< l.10E-06 < 2.32E-06 strontium

- 90 Cl 6.76E-07 6.16E-07 rubidium

- 88*

Cl 1.29E-02 1.20E-02 cobalt

- 58 Cl 8.94E-06 1.12E-05 cesium

- 138*

Cl 9.94E-05 3.29E-05 cesium

- 134 C1 4.04E-07 4.64E-06 cesium

- 137 Ci 4.46E-06 1.74E-05 Total For Period Ci 1.78E-06 1.19E-05 1.30E-02 1.21E-02 Particulates with half lives less than eight days.

o

TABLE 2B REG GUIDE 1.21 CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT FIRST HALF - 1984 LIQUID EFFLUENTS Continuous Mode (1)

Batch Mode 1st 2nd 1st 2nd Nuclides Released Units Quarter Quarter Quarter Quarter strontium

- 89 Ci 5.46E-03 1.21E-02 strontium

- 90 Cl 7.40E-04 7.16E-04 cesium

- 134 Ci 5.51E-02 4.18E-02 cesium

- 137 Cl 1.28E-01 8.60E-02 iodine

- 131 C1 2.97E-02 3.28E-02 cobalt

- 58 C1 2.79E-02 2.47E-01 cobalt

- 60 Cl 1.36E-02 4.67E-02 lodine

- 132 Ci 7.85E-04 manganese

- 54 Ci 1.29E-03 9.77E-03 chromium

- 51 Ci 8.62E-02 zirconium

- 95 Cl 8.55E-04 2.10E-02 ni blum

- 95 Ci 1.96E-03 3.48E-02 m:lybdenum

- 99 Ci 6.36E-06 1.08E-03 barium

- 140 C1 2.89E-05 antimony

- 124 C1 2.07E-03 lodine

- 133 C1 4.64E-03 2.51E-02 antimony

- 125 Cl 6.67E-03 2.48E-02 cobalt

- 57 Cl 6.51E-05 3.66E-05 silver

- Il0m Ci 4.05E-03 3.89E-02 lanthanum

- 140 C1 2.10E-04 tin

- 113 C1 3.16E-05 1.39E-03 rutheniu..

- 103 C1 4.30E-03 nl:blum

- 97 Ci 1.35E-03 1.95E-02 fron

- 59 Ci 7.09E-04

-~,

rr TABLE 2B REG GUIDE 1.21 (CONT'D)

CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT FIRST HALF - 1984 LIQUID EFFLUENTS Continuous Mode (1)

Batch Mode 1st 2nd 1st 2nd Nuclides Released Units Quarter Quarter Quarter Quarter zirconium

- 97 Ci 1.05E-03 t:llurium

- 132 Ci 4.26E-04 cerium

- 141 Cl 1.35E-03 cerium

- 144 Ci 6.28E-03 unidentified C1 4 4.02E-03

< 3.77E-03 Tctal For Period Ci 2.85E-01 7.50E-01

TABLE IC REG. GUIDE 1.21 CALVERT CLIFFS NUCLEAR POWER PLANT FIRST HALF - 1981 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Continuous Mode Batch Mode 1st 2nd 1st 2nd Fission and activation gases Unit QJarter

-Quarter Quarter Quarter krypton

- 85m Ci 5.86E-02 3.30E-02 krypten

- 88 Ci 9.80E-03 4.10E-03 x;non

- 131m C1 3.60E-03 1.00E +00 x:non

- 133 C1 2.13502 3.30E+02 7.70E+01 J.60E+00 x:rion

- 133m Ci.,

8.4'0E-02 2.20E-01 x;non

- 135 Ci 1.90E+00 2.20E+00 argon

- 41 Ci 4.90E-03 2.60E-02 total for period Ci 2.13E+02 3.30E+02 7.91E+01 1.63E+02 Halogens iodine

- 131 Cl 5.51E-03 1.81E-02 4.39E-03 1.40E-03 iodine

- 132 C1 1.10E-06 1.20E-03 iodine

- 133 C1 2.66E-03 4.72E-03 8.40E-03 iodine

- 135 Ci 8.20E-06 bromine

- 82 Ci 1.20E-05 3.30E-05 total for period Ci 8.17 E-03 2.23 E-02 5.24E-03 2.60E-03

~.

Pcrticulates strentium - 89 Ci 5.71E-05 7.75E-05 strontium - 90 Ci 2.00E-05 4.05E-05 cerium

- 141 Ci 5.40E-08 5.30E-07 ruthenium - 103 Ci

-;bidium

- 88 Ci 3.80E-04 1.00E-03 cobalt

- 60 Ci 3.00E-04 cesium

- 138 C1 5.80E-06 3.70E-06 cobalt

- 58 Cl 9.80E-07 total fer. period Ci 7.81E-05 1.19 E-04 8.86E-04 1.00E-03 e

__.7.

e' TABLE 2A REG. GUIDE.1.21 CALVERT CLIFFS NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT-FIRST HALF - 1981 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES -

1st 2nd Est. Total A.- Fission and activation products Units Quarter Quarter Error,. %

1.

Total release (not including

- tritium, gases, alpha)

C1 1.27 E+00 4.31E-01 2.16E+01 2.

Average diluted concentration during period uC1/ml 2.41-09

, 7.52E-10 3.

Percent of applicable limit 2.41+00 7.52E-01 B. Tritium 1.

Total release C1 1.67E+02 2.41E+02 1.81,01 2.

Average diluted concentration during period -

uC1/mi 2.32E-07 4.21E-07 3.

Percent of applicable limit 9.40E-03

' +61 GUT C. Dissolved and entrained gases 1.

Total release C1 2.69E-01 1.12E+00 2.00E+01 2.

Average diluted concentration during period uC1/mi 4.54E-10 1.95E-09

3. - Percent of applicable limit 5.73E-02 6.52E-02 D. Gross alpha radioactivity 1.

Total release

.b 4.81E-04 1.21E-03 3.00E+00 E. Volume'of Waste Releases (prjor to dilution) liters 1.13E+07 9.23E+06 3.00E+00 F. Volume of dilution water used during priod liters 5.93E+11 5.73E+11 1.40E+01 e

o G

e