QCCP 100-16 UNIT 1(2)
REVISION 0 ATTACHMENT A (Page 1 of 5)
EFFLUENT & WASTE DISPOSABLE SEMI-ANNUAL REPORT GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES Period: January through June 1925 FIRST SECOND Est. Total A. FISSION & ACTIVATION GASES UNIT QUARTER QUARTER Error %
- 1. Total Release ci 1.39E+01 1.21E+01 12.4
- 2. Average release rate for the period Sci /sec 1.79E00 1.54E00
- 3.
- Percent of ODCM timit Chimney &
5 52E-03 4.82E-03 Stack 2.49E-04 2.06E 04 B. 10DIMi
- 1. Total iodine-131 Cl 1.11E-04 2.07E-04 40.0
- 2. Average release rate for the period gCl/sec 1.44E-05 2.63E 05 C. PARTICULATES
- 1. Particulates with half-lives >8 days Cl 1.24E-03 3.07E-03 39.1
- 2. Average release rate for the period gCi/see 1.59E-04 3.91E-04
- 3. Gross alpha radioactivity Cl 1.31E-06 4.23E-06**
D. TRITIUM
- 1. Total Release ci 3.57E00 6.21E00 6.2
- 2. Average release rate for the period gCi/see 4.59E-01 7.90E-01 E. Iodine 131 & 133, Tritium & Particulate
- 1. Percent of ODCM timit Chimney & Stack 4.23E-02 1.67E-01 NOBLE GAS GAMMA / NOBLE GAS BETA DOSE LIMITS
- BASED ON PREVIOUS SIX MONTHS AVAILABLE DATA 9602290257 960223 PDR ADOCK 05000254 R
PDR CHEMil2QTR95 14