Figure 1 Draft Approach for a New I&C Regulatory Guidance Infrastructure
ML20100J219
Person / Time
Issue date: 04/09/2020
From: Paul Kallan
NRC/NRR/DNRL/NRLB
To:
Kallan P
References
Download: ML20100J219 (1)


Text

Figure 1 DRAFT Approach for a New I&C Regulatory Guidance Infrastructure 10 CFR 50 10 CFR 50 10 CFR 50 10 CFR 52 10 CFR 50.55a Domestic Licensing of Licenses, Certifications, and Codes and Standards Production and Utilization Appendix A Appendix B Approvals for Nuclear Power Facilities General Design Criteria Quality Assurance Criteria Plants IEEE 6031991 IEEE 2791971 Standard Criteria for Safety Systems Criteria for Safety Systems Criteria for Safety System Computers SingleFailure Criterion Software Development and Digital Reliability Equipment Qualification Instrument Sensing Lines Periodic Testing Setpoints Accident Monitoring Instrumentation Update and streamline: Update and streamline: Update and streamline: Update and streamline: Update and streamline: Update and streamline:

Update and streamline: Update and streamline: Update and streamline:

Reg Guide 1.153 (Criteria for Safety Reg Guide 1.152 (Use of Computers in RG 1.53 (Application of the SingleFailure Reg Guide 1.151 (Instrument Sensing Lines)> Reg Guide 1.22 (Periodic Testing of Actuation RG 1.97 (Criteria for Accident Monitoring Reg Guide 1.168 (Verification, Validation, Release & Reg Guide 1.180 (EMI and RFI Interference on Reg Guide 1.105 (Setpoints for Safety Systems) > IEEE 603 (Criteria for Safety Safety Systems) > Criterion to Safety Systems) > IEEE 379 ANSI/ISA 67.02.01 (Nuclear SafetyRelated Systems) Instrumentation for Nuclear Power Audit for Digital Systems) > IEEE1012 (Standard for Instrumentation)> MILSTD461E/IEC 61000/ Related Instrumentation)> ISAS67.04 Systems for Nuclear Power Generating IEEE 74.3.2 (Criteria for Programmable (Application of SingleFailure Criterion to InstrumentSensing Line Piping and Tubing Plants)> IEEE 497 (Criteria for Accident Verification and Validation) and IEEE1028 (Standard IEEE Std 1050/IEEE Std C62.41/IEEE Std C62.45 (Setpoints for SafetyRelated Stations) Digital Devices in Safety Systems of Nuclear Power Generating Station Safety Standard for Use in Nuclear Power Plants) Reg Guide 1.118 (Periodic Testing of Power Monitoring Instrumentation for Nuclear for Software Review and Audit) Instrumentation Used in Nuclear Power Nuclear Power Generating Stations) Systems) and Protection Systems) > IEEE338 (Periodic Plants) Power Generating Stations)

Reg Guide 1.47 (Bypassed and Inoperable Reg Guide 1.209 (EQ of SafetyRelated Surveillance Testing of Nuclear Power Status Indication)> IEEE 603 Reg Guide 1.169 (Configuration Management Plan Computer Instrumentation and Controls) >

Generating Station Safety) for Software) > IEEE828 (Standard for Software IEEE323 (IEEE Standard for Qualifying Class 1E Reg Guide 1.62 (Manual Initiation of Configuration Management Plans) Equipment for Nuclear Power Generating Protection Systems)> IEEE 603 Stations)

Reg Guide 1.170 (Software Test Documentation for Reg Guide 1.75 (Physical Independence of Software) > IEEE829 (Standard for Software Test Electric Systems)> IEEE 384 (Criteria for Documentation)

Independence of Class 1E Equipment and Circuits) Reg Guide 1.171 (Software Unit Testing for Software)

> IEEE1008 (Standard for Software and Testing)

Reg Guide 1.172 (Software Requirements Specifications for Software) > IEEE830 (Recommended Practices for Software Requirements Specifications)

Reg Guide 1.173 (Developing Software Life Cycle Procedures for Software) > IEEE1074 (Standard for Developing Software Lifecycle Processes)

Notes:

(1) An evaluation would be required to assess the technical feasibility of updating/streamlining the regulatory guides shown in the figure, including the potential consolidation of guidance documents sharing a common topic.

(2) While not shown in the figure, the potential vision for the I&C regulatory guidance infrastructure allows for incorporating, as appropriate, the current set of digital I&C interim guidance into durable I&C regulatory guidance. For example, DI&C-ISG-04 (Highly Integrated Control Rooms & Digital Communication Systems) could be retired by revising Reg Guide 1.152 to endorse IEEE 7-4.3.2-2016, which captures the information from this interim staff guidance document.

(3) For the development of new standards, as well as the need to endorse IEC standards, an evaluation would be required to determine if these can be endorsed via existing regulatory guides thus avoiding the need for developing new ones.