v PHILADELPHIA ELECTRIC COMPANY 23O1 MARKET STREET P.O. BOX 8699 PHILADELPHIA. PA.19101 JOHN S. KEMPER

.. 2'0"!.* '11..

Mr. Harold R. Denton, Director Docket No. 50-352 Office of Nuclear Reactor Regulation U.S. Nuc! ear Regulatory Conmission Washington, DC 20555 3UBJECT: Limerick Generating Station, Unit 1 Primary Reactor Containment Integrated Leakage Rate Test Final Report FILE:

EQUIP 3-1-6 (Leak Testing)

Dear Mr. - Denton:

Enclosed please find 3 copies of the Limerick Generating Station Unit No. I preoperational Primary Reactor Contalrnent Integrated Leakage Rate Test final report. The subject test was conducted during August 1984, in accordance with the requirements of 10CFR50, Appendix J.

The overall containment *eakage rate was found to be lass than the Appendix J acceptance criteria of 0.375 wt.%/ day.

Please do not hesitate to contact us if you desire further discussion or clarification of any aspect of this report.

Very truly yours, NM WJM/cmv/11168402 Enclosure Copy to:

Dr. Thanas E. Murley, Administrator Office of Inspection & Enforcement (with 3 copies of Enclosure)

S. K. Chaudhary, Site Inspector Service List (Attached) 8 t 0

$ToikNO P

e

w-

+

cc: Judge Helen F. Hoyt

-(w/o enclosure)

Judge derry Harbour.

(w/o enclosure)

Judge Richard F. Cole (w/o enclosure)

Judge Christine N. Kohl (w/o enclosure)

-Judge Gary J. Edles (w/o enclosure)

Judge Reginald L. Gotchy (w/o enclosure)

Troy B. Conner, Jr., Esq.

(w/o enclosure)

Ann P. Hodgdon, Esq.

(w/o enclosure)

Mr. Frank R. Romano (w/o enclosure)

Mr. Robert L. Anthony (w/o enclosure)

Ms. Phyllis Zitzer (w/o enclosure)

Charles W. Elliot, Esq.

(w/o enclosure)

Zort G. Fe: kin, Esq.

(w/o enclosure)

Mr. Thomas Gerusky (w/o enclosure)

Director, Penna. Emergency (n/o enclosure)

Management Agency Angus R. Love, Esq.

(w/o enclosure)

David Wersan, Esq.

(w/o enclosure)

Robert d. Sugarman, Esq.

(w/o enclosure)

Martha W. Bush, Esq.

(w/o enclosure)

Spence W. Perry, Esq.

(w/o enclosure) day M. Gutierrez, Esq.

(w/c enclosure)

Atcznic Safety & Licensing

'(w/o enclosure)

Appeal Board Atomic Safety & Licensing (w/o enclosure)

Board Panel Docket & Service Section (w/3 copies of enclosure)

Mr. James Wiggins (w/o enclosure)

Mr. Timothy R. S. Campbell (w/o enclosure) i v

4..-r m--

,v-,vv