Text

,

p# ""'<,

t UNITED STATES y

.t NUCLEAR REGULATORY COMMISSION 3 k.,r j g, WASHING TON, D. C. 20555 ARKANSAS POWER & LIGHT COMPANY DOCKET NO. 50-313 ARKANSAS NUCLEAR ONE, UNIT 1 AMEN 0 MENT TO FACILITY OPERATING LICENSE Amendment No. 87 License No. DPR-51 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for acendment by Arkansas Power & Light Company (the licensee) dated September 14, 1983, as supplemented January 20, 1984 and May 24, 1984, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's rules and regulations set forth in 10 CFR Chapter I; 8.

The facility will operate in confonnity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities aurthorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

l l

I 8412060589 841110 PLii ADOCK 05000313 P

pon

-2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.c.(2) of Facility Operating License No. DPR-51 is hereby amended to read as follows:

Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 87, are

-hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION dd

". Stolz, Chief J n pe ting Reactors Branch'#4 ision of Licensing Attachmen,

/,

Changes t.

~ cal Specifi' Date of.

amber 19,1984 P

'ee a

n m

,-e.-

~

ATTACHMENT TO LICENSE AMENDMENT NO. 87 EACILITY OPERATING LICENSE NO. DPR-51 DOCKET NO. 50-313

+

Replace the following page of the Appen' dix "A" Technical Specifications with the inclosed page. The revised page is identified by Amet.dment number and contains a vertical line-indicating thE' area of change.

s Remove Page

. Insert Page 110b T 110b ao

'\\

w.

' \\.,

t',

g,

rw k

y s

J.

i t

s

\\

s i

f

+

h 1

-(

s 6

-*p 6,

? ~,

"X

+

~

h-

,4 Q 4'

- ~ ' ' '

N, s

l e

-- {

r g

\\

.s t

I L

' t t..

s s.

f

- +

4

'\\ f fY A - -

i

4.14 RADI0 ACTIVE MATERIALS SOURCES SURVEILLANCE Applicability Applies to leakage testing of byproduct, source, and special nuclear radioactive material sources.

Objective To assure that leakage from byproduct, source, and special nuclear radioactive material sources does not exceed allowable limits.

Specification Test for leakage and/or contamination shall be performed by the licensee or by other persons specifically authorized by the Commission or an agreement State, as follows:

1.

Each sealed source, except startup sources subject te core flux, containing radioactive material, other than Hydrogen 3, with a half-life greater than 30 days and in any form other than gas shall be tested for leakage and/or contamination at intervals not to exceed six months.

2.

The periodic leak test required does not apply to sealed sources that are stored and not being used.

The sources excepted from this test l

shall be tested for leakage prior to any use or transfer to another user unless they have been leak tested within six months prior to the date of'use or transfer.

In the absence of a certificate from a transferrer indicating that a test has been made within six months prior to the transfer, sealed sources shall not be put into use until tested.

3.

Each sealed startup source shall be leak tested within 31 days prior to being subjected to core flux and following repair or maintenance to the source.

4.

The periodic leak test does not apply to the four area radiation monitor sources located inside the reactor building or.the boronometer source.

These sources shall be tested for leakage at least once per 18 months.

Amendment No. 23 38', 87 110b

/paith

,9p, UNITED STATES y.') ',, 9 j g NUCLEAR REGULATORY COMMISSION c {'

/.;

WASHINGTON, D. C. 20555

%; Y,/

l l

ARKANSAS POWER & LIGHT COMPANY DOCKET NO. 50-368 l

ARKANSAS NUCLEAR ONE, UNIT 2 l

AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 58 License No. NPF-6 l

1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Arkansas Power & Light Company (the licensee) dated September 14, 1983, as supplemented January 20, i

1984 and May 24, 1984, complies with the standards and requirements j

of the Atomic Engergy Act of 1954, as amended (the Act) and the l

Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the l

provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; i

D.

The issuance of this amendment will not be inimical to the common l

defense and security or to the health and safety of the public; l

and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

l

2-2.

Accordingly, the licensee is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-5 is hereby amended to read as follows:

(2) Technical Soecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 58, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULAT,0RY COMMISSION

[

Yl)fcDL')

James R. Miller, Chief Operating Reactors Branch #3 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: November 19, 1984 qme y-w e

e-4-,

w-w.

yw--

p-,.,.-y,--+w-,

y

-wm mw

--w-,,

-g-,p

,-s

ATTACHMENT TO LICENSE AMENDMENT NO. 58 FACILITY OPERATING LICENSE NO. NPF-6 DOCXET NO. 50-368 Replace the following page of the Appendix "A" Technical Specifications with the enclosed page. The revised page is identified by Amendment number and contains vertical lines indicating the area of change.

The corresponding overleaf page is provided to maintain document completeness.

Remove Page Insert Page 3/4 7-28 3/4 7-28

~

9 PLANT SYSTEMS 1/4.7.9 SEALED SOURCE CONTAMINATION LIMITING CONDITION FOR OPERATION 3.7.9.1 Each sealed source containing radioactive waterial either in excess of 100 microcuries of beta and/or gacma emitting material or 5 microcuries of alpha emitting material shall be free of > 0,005 microcuries of removable contamination.

APPLICABILITY: At all times.

ACTION:

a.

Each sealed source with removable contamination in excess of the above limit shall be immediately withdrawn from use and:

1.

Either decontaminated and repaired, or 2.

Disposed of in accordance with Cmunission Regulations.

b.

The provisions of Specifications 3.0.3 and 3.0.4 are not applicable.

SURVEILLANCE REQUIREMENTS 4.7.9.1.1 Test Requirements - Each sealed source shall be tested for leakage and/or contamination by:

a.

The licensee, or b.

Other persons specifically authorized by the Commission or an Agreement State.

The test method shall have a detection sensitivity of at least 0.005 microcuries per test sample.

4.7.9.1.2 Test Frequencies - Each category of sealed sources (excluding startup sources and fission detectors previously subjected to core flux) shall be tested at the frequencies described below.

a.

Sources in use - At least once per six months for all sealed sources containing radioactive material:

ARKANSAS - UNIT 2 3/4 7-27

PLANT SYSTEMS SURVEILLANCE REQUIREMENTS (Continued) 1.

With a half-life greater than 30 days (excluding Hydrogen 3),and 2.

In any form other than gas.

b.

Stored sources not in use - Each sealed source and fission detector shall be tested prior to use or transfer to another licensee unless tested within the previous six months. Sealed sources and fission detectors transferred without a certificate indicating the last test date shall be tested prior to being placed into use.

c.

Startup sources and fission detectors - Each sealed startup source and fission detector shall be tested within 31 days prior to being subjected to core flux or installed in the core and following repair or maintenance to the source or detector.

d.

Source installed in the Boronometer - This sealed source shall be tested for leakage at least once per 18 months.

4.7.9.1.3 Reports - A report shall be prepared and submitted to the Commission on an annual basis if sealed source or fission detector leakage tests reveal the presence of > 0.005 microcuries of removable contamination.

ARKANSAS - UNIT 2 3/4 7-28 Amendment No. 58