ML20099L418
| ML20099L418 | |
| Person / Time | |
|---|---|
| Site: | Turkey Point |
| Issue date: | 03/18/1985 |
| From: | Bauser M FLORIDA POWER & LIGHT CO., NEWMAN & HOLTZINGER |
| To: | Cole R, Lazo R, Luebke E Atomic Safety and Licensing Board Panel |
| References | |
| CON-#185-142 OLA-1, NUDOCS 8503200582 | |
| Download: ML20099L418 (4) | |
Text
-o NEWMAN & HOLTZINGER,{q,:C P
H-1685 L STflCET, N. W.
- ~
J ACM R. NEWMAN WAS H IN GTON, D. C. 2003 6 WitL AM E.
Agn,s JOHN E.MoLTriNoER.JR.
E.oREoORv mARNES 202-955-66d JANET gfeIECng,"
MAum E AxELRAo J. A. SOURNt4MT,JR.
MERLE W. FALLON' PAULM.RECR f'-
U'
"#f." MAR M A,,
STEVEN R. FRANT2 BRIAN R.GIS M OEORGE L.EDOAR p.
March 18,"~1985.' k'si..f g N o J.
STEVEN C.GOLDBERG m ATHLETES M.SMEA C
DOUMAS & OREEN DERORAM L.HAWMINS RAROL LTN NEWMAN AUSON LEMASTER*
JOMN T. STOWOM, JR.
MOLLY A LINDEMAN JAMES S.WASILE REVIN J. LIPSON 9
MICHAEL A SAUSER DAVID 3.R ASKIN ALVIN M.OUTTERMAN JANEl.RTAN REVIN P.GALLEN DONALD J. SILvERM AN
/
TMOMAS A.SCMMUT2 JACOLT' 49tMMONS JOSEP46 % UBBS MCMAEL F. MEALv posERT I. WHITE
- D" W A-ROSERT LOWENSTEIN IeORMAN A. FLANINGAM OF CoweestL Dr. Robert M. Lazo, Chairman Dr. Richard F. Cole Administrative Judge Administrative Judge Atomic Safety and Licensing Board Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Washington, D.C.
20555 Dr. Emmeth A. Luebke Administrative Judge Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, D.C.
20555 via Messenger Re:
In the Matter of Florida Power and Light Company (Turkey Point Plant, Unit Nos. 3 and 4)
Docket Nos. 50-250 OLA-1, 50-251 OLA-1
Dear Members of the Board:
Last Friday, March 15, 1985, Florida Power & Light Company (FPL) was informed by Westinghouse Electric Corporation' that, on March 9, 1985, it was determined necessary to revise the ECCS evaluation model procedure by which the core flooding rate information generated by the WREFLOOD code is introduced into the BART heat transfer coefficient calculation.
This change was made after Westinghouse discovered, while performing work unrelated to Turkey Point Units 3 and 4, that the procedure for introducing the flooding rate information into the BART code allowed information inconsistent with the WREFLOOD, results to be used, thereby resulting in lower calculated peak clad temperature (PCT) than otherwise would have been calculated in some cases.
FPL has been informed that preliminary ECCS performance reanalysis utilizing the revised procedure results in a calculated PCT higher than the 1972 'F calculated PCT indicated in the August 10, 1984 8503200502 850318
NEW3 DAN O HoLTz!NGER. P.C. " Licensee's Motion for Summary Disposition of Intervenors' Contention (b)," and the " Affidavit of Mark J. Parvin" attached thereto, but well below the 2200 'F limit established by 10 CFR S 50.46.
Reevaluation is continuing and we will keep the Board and parties informed.
Sincerely, M
Michael A. Bauser MAB:cw cc:
Attached Service List O
e 9
e 0
e d
4
, i Ty o%
+,,
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSrI,QN
/,
Mi :29 Yl. -L
- $bNJ BEFORE THE ATOMIC SAFETY AND LICENSING -BOkRD In the Matter of
)
Docket Nos. 50-250-OLA-1
)
'50-251-OLA-1 FLORIDA POWER & LIGHT COMPANY
)
(Turkey Point Nuclear
)
Generating Units 3 and 4)
)
ASLBP No.
84-496-03-LA
)
)
CERTIFICATE OF SERVICE I hereby certify that copies of the attached letter i
of March 18, 1985, to members of the Atomic Safety and Licensing Board were served on the individuals named i
below by deposit in the United States Mail, first class postage prepaid and properly addressed on the date shown below:
Dr. Robert M. Lazo, Chairman
- Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Dr. Emmeth A. Luebke*
Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Dr. Richard F.
Cole
- Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Samuel J. Chilk, Secretary Washington, D.C.
20555 U.S. Nuclear Regulatory Comm'n.
Washington, D.C.
20555 Mitzi A. Young, Esq.*
Attn: William L.
Clements, Chief Office of Executive Legal Director Docketing and Service U.S. Nuclear Regulatory Commission Section Washington, D.C.
20555 i
- Additional service by messenger (cont'd., next page)
~
,n.-
. Norman A. Coll, Esq.
Martin H. Hodder, Esq.**
Steel, Hector & Davis 1131 N.E.
86th St.
4000 Southeast Financial Center Miami, Florida 33138 Miami, Florida 33131-2398 i
Dated this 18th day of March, 1985.
M Michael A. Bauser Newman & Holtzinger, P.C.
1615 L St., N.W.
Washington, D.C.
20036 Telephone: (202) 955-6600
- Additional service by Federal Express.
i e
d
,.,..