-.g w emeaay tr~;-~
. pqr
~
R. F. Durskt s.
W3F1-92-0193 A4.05 QA August 13, 1992 U.S. Nuclear Regulatory Commission
-ATTN: Document Control Desk Washington, D.C. 20555
Subject:
Waterford 3 SES-Docket No. 50-382 Licer.se No. NPF-38 Monthly Operating Report Gentlemen:
Attached is the su.'mt monthly report which covers the operating statistics for tho moi..n of J u.
9' 2. This report is submitted per Section G.9.1.6 of the Waterford 3 % i u.... specifications for Facility Operating License No. NPF-38.
Very truly yo, h, ek%k 'V.. &
RFB/CJT/ssf Attachment ec;
- J.L. Milhoan, NRC Region IV D.L. Wigginton, NRC-NRR R. B.- McGehee N.S. Reynolds F. Yost (Utility Data Institute, Inc.)
J.T. Wheelock (INPO Records Center)
NRC Re-ident Inspectors Office l
l-190007 7
\\T 9208190168 920731
~
PDR ADOCK 05000382 R
M 4
'. 4
- 1. -
,- c..
NRC MONTHLY OPERATING REPORT
SUMMARY
OF OPERATIONS WATERFORD 3 JULY 1992 The unit operated at an average powar of 95.2% and experienced one forced outage during the period.
i-)
i.
d p
i
.{
l
-J;:
j PRESSURIZER SAFETY VALVE FAILURES AND CHALLENGES I
WATERFORD 3 During the month of July 1992, there were no pressurizer safety valve failures or challenges.
4i-d 4
d 3
4 W
m
=-
H
.. +
d
=..
.. OPERATING DATA. REPORT DOCKET NAME: 50-382 UNIT NAME: WATERFORD 3 l
-DATE OF. REPORT: AUGUST, 1992 COMPLETED-BY P. M. CENTOLANZ7 TELEPHONE: 504-739-6683 OPERATING STATUS-1.
Reporting Period: Ju)y, 1992
. Gross Hours in Reporting Period 744 2.
Currently-Authorized Powe.; Level (MWt): 3390
--Maximum Dependable Capacity (Net MWe): 1075
. Design Electrical Rating (Net MWe): 1104 13; Power Level'_to which Restricted (if any).(Net MWe): N/A 4.
Reasons for Restriction (if-any) -
N/A-TH?S MONTH
'YR TO DATE CUMULATIVE
-5.
~ Number of Hours Reactor was Critical.
-719.0, 4,827.5
-49,913.9 6.
Reactor aeserve Shutdown Hours 7.
--Hours Generator was On-line 713.7 4,781.9 49,162.7-
'8.
Unit Reserve
' Shutdown Hours -9.
Gross Thermal Energy-
^
' Generated (MWH)_
2,400,380 16,135,901 161,685,376 10.- GrossiElectrical Energy Generated.(tGGI) 790,100 5,361,640 54,233,060 il.s--Net Electrical Energy.
Generated-(HWH)~
752,424 5,121,487
'51,670,947
- 12.
Reactor. Service Factor 96.6 94.5 83.3 p
13.
Reactor-Availability Factor 96.6 94.5 83.1
- 14. - Unit Service Factor-95.9 93.6 81.8
-15._
Unit Availability Factor 95.9 93.6
-81.8 6
- 16. - Unit Capacity Factor' j[#'
(using MDC) 94.1 93.2 80.0 M
'117.
Unit Capacity-Factor
'(Using DER)
~
91.6 90.8 77.9 f18.. Unit Forced _ Outage Rate 4.1 2.6 4.1
_a
4 6
-OPERATING DATA REPORT DOCKET NAME: 50-382.
UNIT NAME: WATERFORD 3 1
DATE OF REPORT: AUGUST, 1992 i
COMPLETED-BY P. M.
CENTOLANZI TELEPHONE: 504-739-6683 i
OPERATING DATA REPORT (Con't)
' 19.
Shutdowns Scheduled over next 6 Months (type,- date and duration of each):
Refueling, 9/19/92, 56 days
'2 0.
If Shutdown at ena of report period, estimated date of startup: N/A
. 21. ' Unit in Commercial. Operation THIS MONTH YR TO DATE CUMULATIVE 22, Hours-in Reporting Period
'744.0 5,111.0 60,072.0
~
23.
Unit; Forced Outage Hours 30.3 125.9 2,110.7
- 24.. Nameplate Rating (Gross MWe): 1200 f
25.
If Changes' occur in capacity Ratings (Items Number 2 and 24) Since Last Report, Give Reasons:
N/A i
i 4
,,,7 4
-,.,.. _ ~.
I
. 4 j i -1, *
- AVERAGE DAILY UNIT POWER LEVEL
. DOCKET NAME: 50-382 UNIT NAME: WATERFORD 3 DATE OF REPORT: AUGUST, 1992 COMPLETED BY P. M CENTOLANZI TELEPHONES-504-739-6683 MONTH.-
JULY' DAY AVERAGE DAILY POWER LEVEL' DAY AVERAGE DAILY POWER LEVEL (MWe-Net)-
(MWe-Net)
-1 1072
-17 1064 2
1073 18 1065 3
1071-19
--1065
-4 1071 20 1067 5
1070-21 1067
~6
'1069 22' 1066 I
7:
-1068 23 1065 i
8
-1068 24 1066 9-1067 25 1065 10
-1067' 26 1064 11 390 27 1065 12~
125 28 1064 13 988 29 1063 1061 30 1062
- 15-1061 31-1057 l
.16=
1064 r
INSTRUCTIONS on this format, list the average daily unit power '1evel in MWe-Net. for each' day -
g Lin the reporting month. Compute to the nearest whole megawatt.
it f-m
.. g J.L : [
4 '
d
'4
'4 s
. g 2
. UNIT SHUTDOWNS AND POWER REDUCTIONS' DOCKET NUMBER: 50-382 UNIT NUMBER: WATERFORDJ3' DATE OF REPORT: AUGUST, 1992.'
COMPLETED BY P.
M. CENTOLANZI i
. TELEPHONE:' 504-739.-6683-i t
REPORT.FOR' JULY Type Method of Shutting
'F = Forced-Duration Down the Reactor or Cause, Comments and Number
- Date-
.S = Scheduled.
(Hours)-
Reason-(1).
Reducing Power (2)
Corrective' Actions 92-04 920711-
'F 30.3 A
1-
' Outago to repair leakage.on Post i
Accident: Sampling
- System valve.
' LER 92-006.-
6 E
j (2) METHOD
[
(1) REASON (explain) 1 = Manual A = Equipment: Failure B = Maintenance or Test 2 = Manual Scram C = Refueling'.
3'=' Automatic Scram D = Regulatory Restriction ~
4 = Continuation from Previous Period.
[
E = Operator, Training and 5 = Power Reduction License Examination 6 = Other'(explain) l F = Administrative i
G = Operational Error.(explain)
H = Other (explain) b Y
..g
...o s. -.
--....., ~.
-?
..