ML20099F498

From kanterella
Jump to navigation Jump to search
NRC TLD Direct Radiation Monitoring Network.Progress Report January-March 1984
ML20099F498
Person / Time
Issue date: 10/31/1984
From: Cohen L, Costello F, Kramaric M
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
References
NUREG-0837, NUREG-0837-V04-N01, NUREG-837, NUREG-837-V4-N1, NUDOCS 8411260458
Download: ML20099F498 (147)


Text

'

NUREG-0837 Vol. 4, No.1 i

i NRC TLD Direct Radiation Monitoring Network i

1 Progress Report l

January-March 1984 i

i U.S. Nuclear Regulatory Commission l

NRC Region I F. Costello, M. Kramaric, L. Cohen i

i l

"no,v ag~;..af.f m

i j

f-l i

41031 EC PDR i '

w i

" /..~

4 (c.

}:[,

H-4 W

Available from NRC/GPO Sales Program Superintendent of Documents Government Printing Office Washington D. C. 20402 F

A yesr's subscription consists of 4 issues for this publication.

Single copies of this publication are available from National Technical information Service, Springfield, VA 22161 Microfiche of single copies are available frem NRC/GPO Sales Program Washington, D. C. 20555 l

.i f

k'.

NUREG-0837 Vol. 4, No.1 NRC TLD Direct Radiation Monitoring Network Progress Report January-March 1984 Manuscript Completed: October 1984 Date Fublished: October 1984 F. Costello, M. Kramaric, L. Cohen R:gion i U.S. Nuclear Regulatory Commission

(

King of Prussia, PA 19406 l

fa aseoy

/

l i

m

Preface The U. S. Nuclear Regulatory Commission (NRC) Direct Radiation Monitoring Network is operated by the NRC in cooperation with participating states to provide continuous measurement of the ambient radiation levels around licensed NRC facilities, primarily power reactors. Ambient radiation levels result from naturally occurring radionuclides present in the soil, cosmic radiation constantly bombarding the earth from outer space, and the contribution, if any, from the monitored facilities and other man-made sources. The Network is intended to measure radiation levels during routine facility operations and to establish background radiation levels' used to assess the radiological impact of an unusual condition, such as an accident. This report presents the radiation levels measured around all facilities in the Network for the first quarter of 1984. A complete listing of the site facilities monitored is included.

In some instances, two power reactor facilities are monitored by the same set of dosimeters (e.g., Kewaunee and Point Beach).

All radiation measurements are made using small, passive detectors called thermoluminescent dosimeters (TLDs), which provide a quantitative measurement of the radiation levels in the area in which they are placed.

Each site is monitored by arranging approximately 40 to 50 TLD stations in two concentric rings extending to about five miles from the facility. All TLD stations are outside the site boundary of the facility. A complete description of the program can be found in NUREG-0837, Volume 2, Number 4 and NUREG-0837, Volume 3, Number 4.

The National Bureau of Standards (NBS) has been performing an independent study of the following characteristics of the NRC dosimetry system; energy response, angular dependence, temperature and humidity sensitivity, fading, light dependence, self-irradiation, and reproducibility.

NBS has alsc i

tested the response of the NRC's dosimetry system against the requirements of ANSI N545-1975 and NRC Regulatory Guide 4.13.

Details of this testing can be found in NUREG/CR-2560 and NUREG/CR-3120.

The radiation levels are presented as gross and net exposures. The gross exposure includes naturally occurring background radiation, radiation levels resulting from a facility's operation, and the exposure received during transport and storage of the TLD. Net exposures are obtained by subtracting i

an estimate of the exposure received by the dosimeter during transit from the t

gross exposures. All exposures are normalized to a 90-day quarter (standard quarter) and reported in units of milliroentgens (mR). Station numbers for which no data are reported included stations which have been deleted, stations i

for which the TLD was lost during the quarter, or stations for which the TLD was damaged. When control dosimeter data are unavailable, no net exposures are calculated.

Three sets of data are presented for each site. The first set includes the TLD station number, its direction and distance from the site, the integrated l

gross exposure for the period, and the net exposure normalized to a 90-day quarter (standard quarter). All measurements are listed with their respective i

random and total uncertainties.

l-

2 The uncertainties are listed in the following format:

XiS 3 x

x where X = value of the result S = random uncertai.nty expressed as one stardard deviation x

U = combined total uncertainty x

The second set of data summarizes the average net exposure measured in each of the 16 standard windrose sectors around the facility, normalized to a standard quarter. The third set of data summarizes the average not exposure measured at three ranges of distances from the facility, normalized to a standard quarter. When average net exposures cannot be reported because of the unavailability of the site's control dosimeters, the average gross exposures, normalized to a standard quarter, are reported in these two sets of data. The "std.dev." refers to the standard deviation of the measurements made in each sector and range, respectively.

The data for Big Rock Point site for this quarter include sets of data for both the calcium sulfate and the lithium borate elements.

It appears that these dosimeters were exposed to low energy photon radiation sometime between their initial annealing and their final reading. The basis for this determination is the observed difference between the exposures measured by the calcium sulfate and lithium borate elements. The high exposure measurements of the calcium sulfate elements relative to the lithium borate elements are consistent with the over-response of the calcium sulfate elements to low energy photon radiation.

The severe directional dependence of the calcium sulfate elements at low photon energies also contributes significantly to the estimated uncertainty in this data. Because of the lack of transit control dosimeter data, it is not possible to determine whether this low energy photon exposure occurred during transit or while the dosimeters were in the field.

The calcium sulfate data are on pages 8 and 8A of this report. The lithium borate data are on pages 9 and 9A of this report.

For this quarter, the lithium borate data are considered to constitute the best estimate of exposure for Big Rock Point.

This report is one of a continuing series of technical reports covering the results and experiences of the operation of the NRC TLD Direct Radiation

'i '

Monitoring Network.

Suggestions on methods to improve the presentation or analysis of the data contained in this NUREG are appreciated and should be submitted to NRC Region I, 631 Park Avenue, King of Prussia, Pennsylvania 19406, ATTN:

Radiation Dosimetry Specialist.

t i

1

e --

~

. 3; b

LATTACHMENT 1-Sites Monitored During First-Quarter,1984 1.

Arkansas Nuclear One-36.

Millstone 2.

Beaver Valley.

37.

Monticello 3.

-Big Rock Point 38.

. North Anna 4.-

Braidwood 139.

Oconee 5.

Browns Fe'rry 40.-

Oyster Creek 6.

' Brunswick

'41.

Palisades 7.

Byron 42.

Palo Verde 8.

Callaway' 43.-

Peach Bottom 9.

Calvert Cliffs 44.

Perry 10.

Catawba 45.

Pilgrim 11.

Clinton

. 46.-

Prairie-Island 12.

Comanche Peak.

47.

Quad Cities 13.

D. C. Cook 48.

Rancho Seco 14.

Cooper-49.

Robinson 15.

, Crystal River 50.

St. Lucie 16.

Davis-Besse 51.

Salem / Hope Creek 17.

Diablo Canyon 52.

San Onofre 18.

Dresden

'53.

Seabrook 19.

Duane Arnold 54.

SequoyahL 20.

Farley -

55.

Shoreham 21.

Fermi 56.

Summer 22.

FitzPatrick/Nine Mile Point 57.

Surry 23.

Fort Calhoun 58.

Susquehanna 24.

Fort St. Vrain 59.

Three Mile Island 25.

Ginna 60.

Trojan 26.

Grand Gulf 61.

Turkey Point 27.

Haddam Neck 62.

Vermont Yankee 28.

Hatch 63.

Washington Nuclear 2-29.

Indian Point 64.

Waterford 30.

Kewaunee/ Point-Beach 65.

Watts Barr 4

31.

Lacrosse 66.

Wolf Creek 32.

LaSalle 67.

Yankee Rowe l

33..

Limerick 68.

Zimmer i

34.

Maine Yankee 69.

Zion j

35.

-McGuire

['

l L.

u

4 ARKANSAS ~

TLD DIRECT RADIATION ENVIR0t1 MENTAL--MONITORING FOR THE PERIOD:831208-840406 120 DAYS FIELD TIME 85 DAYS-NRC-LOCATION GROSS tlET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deg.) -(mi.).

+r Rdm; Tot.-

+- Rdm; DATA Tcit.

001 4

0.4 22.6 +-'

.7 3.4.

N0 flET

.7 ;

002 353 4.1 22.4 +-

3.4:

N0 flET DflTA

.7 ;

003 32 1.3 23.7 +-

3.6 NO NET DftTA

.6 ;;

004 13 3.3 21.2 +-

3.2 N0 flET DflTA 005 53 1.5 22.1 +-

.7 ;

3.3 N0 ilET DflTA 006 37 3.6 20.0 +-

.6 3.0 N0 flET DATA.

.8 ;;

007 78 2.5

-26.0 +-

3.9 NO NET DfliA 008 60 3.2.

MISSING OR DAMAGED DOSIMETER 009 92 0.5' 24.9 +-

.7 ;

3.7 N0 flET DfiTA 010 83 5.5 22.5 +-

.7 ;

3.4 N0 llET DATA 011 122 2.1 21.4 +-

.6 ;

3.2 N0 ilET DATA 012 109 6.8 23.5 +-

.7 ;

3.5 N0 flET DATA 013 138 2.6 19.9 +-

.6' 3.0 NO NET DATA 014 130 4.9 MISSINGORDAllAGEDDOSIMETER 016 167 4.4 22.4 +-

.7 ;

3.4 110 NET Df!TA i

017 171 0.4 21.6 +-

.6 ;

3.2 N0 NET DATA 018 189 3.2 22.3 +-

.7 3.3 t10 NET DflTA

.6 ;

019 205 2.9 21.4 +-

3.2 NO NET DATA-020 195 5.8 20.7 +-

.6 ;

3.1 N0 flET DflTA

.7 ;

021 235 0.5

-23.5 +-

3.5 fl011ET DflTA 022 230 3.6 MISSINGORDAllAGEDDOSIMETER 023 257 2.8 MISSING OR DAMAGED DOSIMETER 024 243 4.5 21.2 +-

.6 ;

3.2 t10 flET DATA j

025 279 1.2 26.6 +-

.8 ;

4.0 110 ilET DflTA i

026 263 4.3 23.1 +-

.7 ;

3.5 110 ilET DflTA 027 298 0.4 23.4 +-

.7 ;

3.5 110 flET DATA 028 293 5.8 23.5 +-

.7 ;

3.5 Il0 llET DflTA 029 326 1.9 23.6 +-

.7 ;

3.5 t10 ilET DfiTA 030 308 4.8 22.2 +-

.7 ;

3.3 t10 f1ET Df!TA I

031 345 1.3 23.7 +-

.7 ;

3.6 t10 flET DflTA 032 335 4.2 21.2 +-

.6 ;

3.2 il0 flET DATA 033 110 0.8 24.2 +-

.7 ; -3.6 l10 flET DftTA 039 112 6.0 22.2 +-

.7 ;

3.3 t10 flET DflTA 040 147 8.0 23.2 +-

.7 ;

3.5 ll0 flET DATA 041 106 17.

21.9 +-

.7 ;

3.3 N0 flET DfTA 042 310 17.

20.8 +-

.6 ;

3.1 t10 flET DfiTA 043 0

5.2 23.4 +-

.7 ;

3.5 Il0 ilET DATA 044 0

9.1 22.7 +-

.7 ;

3.4 N0 ilET DfiTA 045 0

8.9 20.3 +-

.6 ;

3.0 l10 NET DfiTA 046 0

8.3 22.3 +-

.7 3.3 110 flET DATA N0 TRAllSIT DOSE CALCULATED (TLD CONTROLS; MISSING OR OTHERHISE il0T COM i

5 ARKANSAS FOR THE PERIOD 831208-840406 TLD DIRECT RADIATION ENVIRONMENTAL MONITOPING RZIMUTH (deg.)

AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dav.

348.75-11.25 (N) 16.7 +

.I 6

11.25-33.75 (NNE) 16.B +- 1.3 2

33.75-56.25 (NE) 15.8 +- 1.1 2

56.25-78.75 (ENE) 19.5 +- B.O 1-78.75-lOL.25 (E) 17.8 +- 1.3 2

10L.25-123.75(E5E) 17.9 +

.9 5

123.75-146.25(SE) 14.5 +- B.O 1

14 5.25-158.75 ( 55E )

17.1 +

.1 2

168.75-191.25(5) 15.5 4-.1 2

19L.25-2l3.75(55N) 15.0 4

.1 2

213.75-236.25(SW) 17.6 4-B.0 1

236.25-258.75(WSW) 15.9 +- B.O 1

258.75-281.25(W) 18.B +- 1.9 2

281.25-303.75(WNW) 17.6 +

.1 2

303.75-326.25(NN) 16.8 +- 1.1 3

326.25-348.75(NNN) 16.B +- 1.3 2

DISTANCE (mi) FROM THE REACTOR AVER. EXPOSURE RATE 4 IN GROUP

( rnR/ 5t d, 0 t r'. ) + -5t d. De v.

j B-2 17.7 +- 1.0 11

(

2-5 16.4 +- 1.2 13

>5 16.7 +

.5 12 l

UPHIND CONTROL DATA NO DATA NO DATA o

L.

6

. BEAVER VALLEY TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831212-840411 121 DAYS FIELD TIME 112 BRYS NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deg.)

(mi.)

+- Rda

+- Rdm 20.9 +; Tot.

16.1 + ; Tot.

002 6

13

.6 ;

3.1

.6 ;

2.8 004 31 12 22.7 +-

.7 3.4 17.5 +-

.7 ;;

.6 3.0

.6 ;;

005 55 9.4 22.0 +-

3.3 16.9 +-

3.0 006 60 9.5 22.5 +-

.7 3.4 17.3 +-

.6 3.0

.7 ;;

.6 ;;

007 97 8

23.0 +-

3.5 17.7 +-

3.1 008 110 4.3 24.7 +-

.7 ;

3.7 19.1 +-

.7 ;

3.3 009 110 2.9 03.0 +-

.7 3.5 17.7 +-

010 91 2.4 24.0 +-

.7 ;

.6 3.1 3.6 18.6 +-

.7 ;

1.0 *;

3.2

.8 ;;

Oli 77 3.7 32.5 +-

4.9 25.3 +-

4.1 012 153 4.2 MISSINGORDAllAGEDDOSIMETER

'013 170 4.4 20.3 +-

.6 3.0 15.6 +-

.6 ;;

.6 2.8 3.2 16.3 +-

.6 ;

014 190 4.4 21.3 +-

2.9

.6 3.2 16.5 +-

.6 ;

015 208 3.5 21.4 +-

016 264 5.6 22.4 +-

.7 ;

2.9 3.4 17.2 +-

.6 ;

017 270 6.3 22.7 +-

.7 ;

3.0 3.4 17.5 +-

.6 ;

018 232

.4 21.7 +-

.6 ;

3.0

.6 ;;

3.2 16.7 +-

.7 ;;

2.9 019 267 2.3 23.9 +-

3.6 18.4 +-

.7 ;

3.2 020 294 3.4 20.0 +-

.6 3.0 15.3 +-

.7 ;;

.6 2.7

.7 ;;

021 286 1.4 24.4 +-

3.7 18.9 +-

3.2 022 220 1.3 21.1 +-

.6 ;

3.2 16.2 +-

.6 ;

2.9 023 255

2. 3 MISSING OR DAMAGED DOSIMETER 024 209 2.1 22.8 +-

.7 ;

3.4 17.6 +-

.6 ;

3.1 025 186 2.1 23.6 +-

.7 3.5 18.2 +-

026 190 2.2 23.4 +-

.7 ;

.6 3.1

.6 ;;

3.5 18.1 +-

027 125 2

24.4 +-

.7 ;

3.1 3.7 18.9 +-

.7 ;;

.7 3.2

.6 ;;

028 87 1.6 23.1 +-

3.5 17.8 +-

3.1 029 59 1.5 21.1 +-

.6 3.2 16.2 +-

.6 ;

2.9

.7 ;;

030 50 1.2 21.9 +-

3.3 16.8 +-

.6 ;

3.0 031 320 1.2 24.7 +-

.7 ;

3.7 19.1 +-

.7 ;

3.3 032 325 3.5 23.1 +-

.7 3.5 17.8 +-

.61 3.1 033 341 2.5 22.0 +-

.7 ;

3.3 16.9 +-

.6 ;

3.0 034 343 5.2 21.9 +-

.7 ;

3.3 16.9 +-

.7 ;;

.6 3.0

.6 ;;

035 9

3.6 22.9 +-

3.4 17.7 +-

3.1 036 14 3.3 26.2 +-

.8 ;

3.9 20.3 +-

.7 ;

3.4 037 37 3

19.4 +-

.6 2.9 14.8 +-

.6 ;

2.7 038 22 1.8 23.0 +-

.7 ;

3.4 17.7 +-

.6 ;

3.1

.7 ;;

039 351 1.6 22.2 +-

3.3 17.1 +-

.6 ;

3.0 040 344 15, 20.1 +-

.6 ;

3.0 15.4 +-

.6 2.8 041 344 15, 19.9 +-

.6 ;

3.0 15.2 +-

.6 ;;

2.7 TRANSIT LOSE =

.9

+-

.4 ; 1.7 r

l l

l

-7

' BEAVER VALLEY' -

FOR THE PERIOD 831212-840411 TLD DIRECT RADIATION ENVIRONMENTAL HONITORING MZIt1UTH (cie g.1 NET MVER. EXPO 5URE RMTC 4 IN GROUP (mR/Std.Qtt.) +-Std.Dev.

340.75-11.25 (N) l6.9 +

.8 3

11.25-33,75 (NNE)

LB.5 t-1.5 3

32.75-5E.25 (NC)

LE.2 +- 3.2 3

56.25-78.75 (ENE) l9.6 +- 5.0 3

78.75-101.25 (E)

L8.0 +

.5 3

101.25-123,75(ESE)

LB.4 +- 1.0 2

123.75-146.25(SEi LB.9 +- 0.0 1

145.25-165.75(55E)

NO DMTM+-No DMTM 5

s IED,75-19L.25(E)

L7.L +- 3.3 4

13L.25-213.75(55N)

L7.0 +

.6 2

213.75-236.25(SN) 16.4 +

.3 2

j 236.25-258.75(NSN)

N0 DATR+-No DATR D

258.75-28l.25(H) 17.7 +

.6 3

2eL.25-303.75(HNH)

L7.L +- 2.5 2

333.75-32E.25(NH) 19.4 4-.9 2

32G.25-34G.75(NNH)

LE.9 +-

.9 2

i i

r i

j DISTANCE (ml) FFort THE REACTOR NET RVER EXPO 5URE RATE 9 IN GROUP (mR/Wd. der,) +-5td.Dev.

D-2 17.6 +- 1.t 9

2-5 L7.8 +- 2.3 18 l

>5 17.L +

.5 9

UPHIND CONTROL DMTM L5.3 t-.1 2

L.

5 8

BIG ROCK TLD DIRECT RADIATION ENVIRONMEtITAL MONITORING FOR THE PERIOD 831212-840420 130 DAYS FIELD TIME 94 DAYS Calcium Sulfate NRC LOCAT10rl GROSS NET EXPOSURE RATE STATI0t1 AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.

(deg.)

(mi.)

+- Rdm Tot.

41.8 +; Tot.

+-Rdm$TDATA 001 208 4.9 3.7

  • 35.9 N0 N I

002 220 3.6 35.1 +-

2.8 30.2 N0 NET DATA I

003 204 2.4 25.2 +-

.3 21.6 N0 NET DATA 6.2 ;l 64.0 004 176 3.3

'52.3 +-

8.1 45.0 NO NET DATA 005 161 4.6 74.4 +-

NO NET DATA 006 133 4.7 94.4 +-

3.8 81.1 N0 NET DATA 8.3 ;

007 116 3.7 46.5 +-

39.9 N0 NET DATA 11.7 ;;

008 111 4.7 54.2 +-

46.6 N0 NET DATA 009 98 4.5 75.3 +-

4.9 ;

64.7 N0 NET DATA 010 88/

12.

56.9 +-

7. 2 '

48.9 NO NET DATA 011 83/

16.

MISSINGORDAMEGEDDOSIMETER 012 83/

16.

IIISSIl1G OR DAMAGED DOSIl1ETER 013 83/

16, 74.7 +-

3.3 '

64.2 N0 NET DATA 014 77 3.4 101.7 +-

4.3 !

87.5 110 NET DATA i

015 96 1.8 69.4 +-

1.7 59.6 N0 flET DATA 2.9 ;;

016 118 2,0 40.2 +-

34.5 110 NET DATA 017 134 2.0 132.5 +-

7.2 ; 114.0 110 NET DATA 018 222 1.9 55.1 +-

1.5 '

47.3 fl0 NET DATA 019 194 1.4 67.8 +-

3.9 59.3 110 NET DATA I

10.4l107.0 1

020 179 1.5 119.3 +-

7. 0 102.6 N0 NET DATA 021 153 1.1 124.5 +-

110 NET DATA NOTRAtlSITDOSECALCULATED(TLDC0tlTROLSllISSINGOROTHERWISEfl0TCOMPL i

i I

i 4

3

8-A

-BIG ROCK-FOR THE PERIOD 831212-840420 Calcium Sulfate TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dog.)

AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qte.) t-Std,Dev.

348,75-11.25 (N)

NO DRTA+-NO DATR S

11.25-33.75 (NNE)

No DATA +-NO DATR S

33.75-58.25 (NE)

No DATA +-NO DATR 6

1 56.25-78.75 (ENE) 79.4 +- 0.0 1

l 79.75-10l.25 (C) 46.5 +- S.5 3

19L.25-123.75(ESE) 32.5 +- 4.9 3

123.75-146.25(SE) 78.5 +- 15.7 2

1 146.25-165.75(SEE) 65.5 4-24.5 2

a 168.75-191.25(5) 59.1 4-32.5 2

15L.25-213.75(SSNP 3L.1 4-11.5 3

213.75-236.25 (SW )

3l.2 4-9.9 2

i 238.25-250.75(W5W)

NO DRTAt-NO DATA 9

250,75-201.25(W)

NO DRTAt-NO DATR 9

201.25-303.75(WNW)

NO DATAt-NO DATR S

i 303.75-326.25(NH)

No DATAt-No DATR G

326,25-348.75(NNN)

No DATA +-No DATR 8

s

[

I s

03STANCElmt) FROM THE PEACTOR RVER.EXPOSUPE RATE

+ IN GROUP

~

(rnR/5td.Otr.7 4 -51 d. De v,

9-2 60.2 +- 25.9 7

2-5 4L.E +- 17.6 10 55 39.4 +- 5.0 1

i UPNIND CONTROL DATA 5t.7 +- B.O 1

t

9 PIG ROCK TLD DIRECT RADIATION ENVIRONMENTAL MONITORIllG FOR THE PERIOD 83:212-840420 130 DAYS FIELD TIME 94 DAYS Lithium Borate _

NRC.

LOCATION GROSS 11ET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.

+- Rdm

+- Rdm' Tot.

28.7 +; Tot.

(deg.)

(ml.)

-2.0 ;

7.2 N0tlkTDATA-001 208 4.9 002

'220 3.6 24.6 +-

1.7 -

6.1 N0 NET DATR I

003 204 2.4 21.7 +-

1.5 5.4 N0 llET DATA 004 176 3.3 23.7 +-

1.7!

5.9 N0 NET DATA 005 161 4.6 26.1 +-

1.8 ;

6.5 NO NET DATA 006 133 4.7 27.2 +-

1.9 '

6.8 NO NET DATA 1

007 116 3.7 24.3 +-

1.7l 6.1 fl0 NET DATA 008 til 4.7 24.4 +-

1.7 '

6.1 NO NET DATA 009 98 4.5 26.5 +-

1.9l 6.6 N0 NET DATA i

010 88/

12, 22.1 +-

1.5

  • 5.5 N0 flET DATA 011 83/

16.

MISSINGORDAMEGEDDOSIMETER i

012 83/

16.

-MISSING OR DAMAGED DOSIMETER 1.7 6.1 N0 ilET DATA i

013 83/

16.

24.6 +-

2.0 ;

7.0 (10 flET DATA 014 77 3.4 28.2 +-

1. 9 ;'I 6.4 t10 flET DATA 015 96 1.8 25.8 +-

016 118 2.0 26.1 +-

1.8 6.5 110 NET DATA I

j 017 134 2.0 26.6 +-

1.9 6.7 fl0 NET DATA I

i 018 222 1.9 22.6 +-

1.6 5.7 110 NET DATA I

019 194 1.4 23.5 +-

1.6 5.9 fl0 NET DATA I

l 020 179' l.5 27.2 +-

1.9 6.8 110 flET DATA I

021 153 1.1 31.1 +-

2.2 7.8 tl0 flET DATA t10TRANSITDOSECALCULATED(TLDC0tlTROLSl11SS!!1GOROTHERWISEIIOTCOMPLETE)

F i

i i

i I

l l

9-A hfd PERIOD 831212-8 m 20 t_tthtum Borat*

TLD DIRECT RADIATION ENVIRONMENTAL MONITORING AVER. EXPOSURE RATC 4 IN GROUP RZIMUTH (dag.)

(mR/Std.Qtr.) t-Std.Dev.

348.75-il.2'l (N)

NO DATA +-NO DATR 0

11.25-33.75 (NNE)

NO DRTA+-NO DATR 0

33.75-56.25 (NE)

NO DATA +-NO DATR 0

56.25-78.75 (ENE) 19.5 +- 0.0 1

78.75-101.25 (E) 17.2 +- 1.6 3

10l.25-123.75(ESE) 17.2 +

.7 3

123,75-146.25(SE) 18.6 +

.3 2

14 5.25-168.75 (55E )

IS.B 4-2.4 2

160.75-191.25(5) 17.5 4-1.7 2

19L.25-2L3.75(55H) 17.0 4-2.5 3

213.75-236.25(SH) 16.3 +- 1.0 2

236.25-250.75(H5H)

NO DATAt-No DATR G

250.75-201.25(H)

NO DRTAt-NO DATR G

201.25-303.75fHNH)

NO DRTRi-NO DATA G

303.75-326.25(NH)

NO DATAt-N0 DATR 0

326.25-348.75(NNN)

NO DATA *-N0 DATR 0

OISTANCE(mt) FROM THE REACTOR RVER. EXPOSURE RATE

+ IN GRoljP (mR/5td.0tr.) + -5t d. De v.

10.1 +- 1.9 7

Q-2 17.7 +

1.5 19 2-5 15.3 +- 0,0 1

>5 UFNINO CONTRot. ORTA 17.0 +- 0.0 1

10 BRAIDWOOD i

TLD DIRECT RADIATION ENVIRONMENTAL M0tlITOR!tlG FOR THE PERIOD 831209-840407 120 DAYS FIELD TIME 86 DAYS IIRC LOCATION GROSS t1ET EXPOSURE RATE SIAT1011 AZIMUTH /DIST EXPOSURE (mR) mR/St d.0t r.

(deg.)

(mi.)

+- Rdm; Tot.

+- Rdm 10.7 + ; Tot.

001 351

.8 18.4 +-

.6

  • 2.8

.7 3.7 2.5 9.2 +-

.7 ;

002 19 1.3 17.0 +-

.5 I 3.5

.5 2.7 10.1 +-

.7 ;

.5 *l2.7 003 45 2

17.9 +-

3.7

.7 ;;

004 66 2.1 18.1 +-

10.3 +-

3.7 I

005 87 1.8 18.4 +-

.6 2.8 10.7 +-

.7 3.7

.7 ;;

I 006 114 2

17.9 +-

.5 2.7 10.2 +-

3.7 007 133 2.7 18.7 +-

.6 I 2.8 11.0 +-

.7*

3.7 008 151 2.8 17.7 +-

.5 !

2.6 9.9 +-

.7 !

3.6 009 178 3.9 23.6 +-

.71 3.5 16.1 +-

.9 4.4

.7,l 010 197 2.8 17.7 +-

.5' 2.6 9.9 +-

3.6

.5 l 2.8 011 222 1.4 17.9 +-

2.7 10.2 +-

.71 3.7 012 252 1.1 18.8 +-

.6 11.1 +-

.7' 3.8

.5j; 013 261 1.0 17.7 +-

2.6 9.9 +-

.7 !

3.6 014 278 1.2 16.9 +-

.5 2.5 9.1 +-

.7' 3.5 015 310 1.3 17.7 +-

.5 I 2.6 9.9 +-

.7 I 3.6

.5 '!

2.6 016 335 1.0 17.4 +-

. 7 lI

.5 9.6 +-

3.6 017 359 1.5 17.8 +-

2.7 10.0 +-

.7 3.6 018 018 3.5 23.9 +-

.7 I 3.6 16.4 +-

.9 ;

4.4 019 042 6.3 MISSINGORDAllAGEDDOSIMETER 020 069 5.7 20.2 +-

.6*

3.0 12.5 +-

.8' 3.9 021 086 6.8 21.0 +-

.6 !

3.1 13.4 +-

.8 I 4.0 022 100 10' 19.2 +-

.6 2.9 11.5 +-

.7 !

3.8 023 45/

4.9 19.5 +-

.6 ;*

2. 9 11.8 +-

.7 3.9 024 070 4.2 17.9 +-

.5 !

2.7 10.2 +-

.7 ;

3.7 025 086 4.1 18.0 +-

.5 2.7 10.3 +-

.7 I 026 113 4.4 18.9 +-

.6 ;*

3. 7
2. 8 11.2 +-

.7 I 3.8 027 142 6.4 20.1 +-

.6 !

3.0 12.5 +-

.8 !

3.9 028 161 6.1 18.6 +-

.6' 2.3 10.9 +-

.7 ;

3.7 029 180 6.1 24.7 +-

.7 I 3.7 17.2 +-

.9' 4.5 030 191 5.8 22.8 +-

.7 I

.8 I 3.4 15.2 +-

.8 l 4.3 031 230 5.8 20.4 +-

.6 I 3.1 12.8 +-

4.0 032 266 5.3 MISSIllGORDAllAGEDI'05! METER 033 289 4.1 20.1 +-

.6' 3.0 12.4 +-

.8' 3.9

.6 l 2.8 034 315 4.3 20.1 +-

.6 3.0 12.5 +-

.8 I 3.9 035 333 4.5 18.5 +-

10.7 +-

.7 l 3.7 036 000 5.9 it!SS!!IGORDAllAGEDDOS! METER 037 021 5.3 17.4 +-

.5 '

2.6 9.6 +-

.7' 3.6 038 190 10' 21.1 +-

.6 I 3.2 13.5 +-

.8 I 4.1

.5l2.6 039 224 13' 18.1 +-

.5 2.7 10.3 +-

.7 !

3.7 040 224 13' 17.5 +-

9.8 +-

.7 ;

3.6 TRANSIT DOSE =

8.2

+-

4 ; 2.2

I 11

-BRAIDWOOD FOR THE PERIOD 831209-840407 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (deg.)

NET RVER. EXPOSURE RATE 6 2N GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-11.25 (N) le.4 +

.5 2

11.25-33.75 (NNE)

IL.? +- 4.8 3

33.75-56.25 (NE) 16.8 +- 1.2 2

56.25-78.75 (ENE)

IL.B +- 1.3 3

79.75-101.25 (E) 11.5 +- 1.4 4

196.25-123.75(ESE) le.7 +

.7 2

123.75-146.25tSE) 11.7 +- 1.1 2

145.25-168.75 ( 55E )

10.1 4

.7 2

165.75-151.25(5) 15.5 4-1.5 4

151.25-213.75tS5N)

U.5 4-5.5 1

213.75-236.25(SN) 18.5 4-1.0 2

236.25-258.75(W9W) ll.1 +- 5.0 1

250.75-201.25tW) 9.5 +

.6 2

281.25-303.75(WNW) 12.4 +- 8.0 1

303.75-326.25(NH) 11.2 +- 1.8 2

326.25-348.75(NNN) 10.2 +

.5 2

02STMNCC( m t ) FR0ft THC REACTOR NET RVER.EXPOSUPC PATE

+ 2N GROUP (mR/5td,Gte.) 4-5td.Dev.

3-2 10.1 +

.5 12 l

2-5

!!.5 +- 2.2 13 55 12.5 +- 2.2 10 UPHINO CONTROL DATH 10.9 +

.4 2

i i

i

12 BROWils FERRY TLD DIRECT RADIAT!0tl EllVIR0tiMEtlTAL [10ti!TORIllG FOR THE PERIOD 831214-840427 135 DAYS FIELD TIME 91 DAYS IIRC LOCATI0tl CROSS tlET EXPO!URE RATE l

STATION AZIllVTH/DIST EXPOSURE (mR) mR/Std.0tr.

(dig.)

(ml.)

+- Rda; Tot.

+- Rdm 16.0 + ; Tot.

001 13e 9

19.8 +-

.6 3.0 002 133 5.5 20.1 +-

.6 *;

.7 l' 3.4 3.0 16.3 +-

.7 3.4 003 153 4.3 MISSIllGORDAlIAGEDDOSIMETER l

004 210 5.8 22.'3 +-

.7' 3.3 18.5 +-

.8*

3.7 l

005 220 6

20.2 +-

.6 I 3.0 16.4 +-

.7 I 3.4

.6 l 3.1 006 245 4.5 24.4 +-

.7 3.7 20.5 +-

.8 I 4.0 007 269 1.9 21.0 +-

17.1 +-

.7 I 008 257 11, 21.0 +-

.6 *;

3.5 3.2 17.2 +-

.7 I 3.5 009 295 7

22.8 +-

.7 !

3.4 19.0 +-

.8 I 3.8 010 292 4.5 21.5 +-

.6*

3.2 17.7 +-

.7 I 3.6 011 269 1.9 21.5 +-

.6 I 3.2 17.6 +-

.7 !

3.6 012 240 2.6 20.9 +-

.6 !

3.1 17.1 +-

.7' 3.5 013 220 1.7 22.0 +-

.7' 3.3 18.1 +-

.8 I

.8 l 3.7 014 268 17 22.4 +-

.7 I 3.4 18.5 +-

3.7 015 201 3

MISSING OR DAllAGED DOS! METER 016 181 3

22.1 +-

.71 3.3 18.0 t

.8 ;

3.7 017 50 9.5 ft!S$1NG OR DAMAGED DOS! METER 018 51 3.5 21.2 +-

.6 3.2 17.4 +-

.7 ;

3.6 MIS $1NGORDAl'IAGEDDOSIMETER 019 62 3.2 020 86 2.8 25.1 +-

.8' 3.3 21.2 +-

.8 ;

4.1 021 til 3.1 MISSINGORDAllAGEDDOSIMETER 022 64 1.1 27.0 +-

.8*

4.1 23.1 +-

.9' 4.3 023 90 26 23.5 +-

.7 I 3.5 19.7 +-

.8 I 3.9 024 111

.8 23.4 +-

.7 I 3.5 19.6 +-

.8 I 3.9 025 46 2.2 15.0 +-

.4 I 2.2 11.2 +-

.6 I 2.8 026 26 1.7 26.5 +-

.8 I 4.0 22.6 +-

.9 I 4.3 3

027 333 1.7 22.2 +-

.7

3. 3 18.4 +-

.8 !

3.7 028 335 1

25.0 +-

.7 I 3.7 21.1 +-

.8 ;

4.1 i

029 27 3.8 MIS $ltlGORDAl1AGEDDOSIMETER l

030 0

4 22.2 +-

.7 ;

3.3 18.3 +-

.8.8 l' 3.7 031 340 5.3 22.8 +-

.7*

3.4 18.9 +-

3.8 032 312 12 23.7 +-

.7 I 3.5 19.8 +-

.8' 3.9 033 0

1.5 25.2 +-

.8 !

3.3 21.3 +-

.8 l 4.1 034 52 7

22.2 +-

.7' 3.3 18.3 +-

.8*

.8 l 3.7 035 95 5.4 22.9 +-

.7 I 3.4 19.1 +-

3.8 036 60 5.6 111SSIllG OR DAl1 AGED DOSIMETER 037 149 7.8 21.3 +-

.6 l' 3.2 17.5 +-

.7' 3.6 038 164 7

19.8 +-

.6 3.0 16.0 +-

.7 l 3.4 TRANSIT DOSE =

3.6

+-

.4 ; 1.7 1

13 BROWNS FERRY FOR THE PERIOD 831214-840427 TLD DIRECT RADIATION ENVIRONf1 ENTAL HONITORING AZIMUTH (dag.)

f4CT AVER. EXPOSURE RATE

+ IN GROUP (mR/Std.Qtr.) t-Std.Dav.

348.75-11.25 (N) 19.B +- 2.1 2

1I.25-33.75

( titeE 1 22.B +- 0.0 1

33.75-56.25 (tit) 15.6 +- 3.9 3

56.25-70.75 (Et4E) 23.1 +- 0.0 1

78.75-101.25 (E) 20.0 +- 1.I 3

10L.25-123.75(ESE) 19.6 +- 0.0 1

123.75-146.25(SC) 16.1 +

.2 2

146.25-160.75(55C) 16.7 4-1.0 2

160.75-131.25(5) 10.3 4- 0.0 1

194.25-2L3.75(55H) 10.5 4- 0.0 1

213.75-236.25(SW) 17.3 4-1.2 2

236.25-250.75(64S61) 10.8 +- 2.4 2

250.75-201.25(64) 17.4 +

.3 2

20 L 25-303.75 (64f4641 10.3 +

.9 2

303.75-326.25(flHa 19.8 +- 0.0 1

3 26. 2 5-3 4 0. 75 ( tit 4 H )

19.5 +- 1.4 3

OISTAtJCC(mt) FPori THE PEACT0P NCT RVCP.EltPOCUPC PATC 4 Ife GPOUP (nR/Std,0tr.) +-5td.Dev, 0-2 19.9 +- 2.2 9

2-5 17.7 +- 3.0 0

l 55 17.8 +- 1.4 12 I

UPN!!40 Cot 4TPOL ORTA 17.9 +

.9 2

l i

14 BRUNSWICK TLD DIRECT RADIATION ENVIR0llMEllTAL MONITORIllG j

FOR THE PERIOD 831213-840411 120 DAYS FIELD TIME 90 DAYS NRC LOCAT!0tl GROSS NET EXP05URE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/St d.0t r.

(deg.)

(mi.)

+- Rdm; Tot.

+- Rdm 8.3 + ; Tot.

001 260 2.2 15.6 +-

.5 ;

2. 3

.7 3.3

.7 ;;

002 245 3.4 15.9 +-

.5 2.4 8.6 +-

.5 ;

3.4 003 231 3.8 15.4 +-

2.3 8.0 +-

.5 ;

.7 3.3

. 7 *;

004 210 4.9 17.6 +-

2.6 10.2 +-

3.5 005 186 4.3 1'.2 +-

.5 I I

2.6 9.8 +-

.7 3.5

.5 ;l 2.4 006 270 4.5 15.5 +-

.5 2.3 8.2 +-

.7 I 3.3 007 272 4.4 16.0 +-

8.6 +-

.7 l 3.4 008 73 1.3 17.9 +-

.5' 2.7 10.6 +-

.7 3.6

.5 2.7 10.7 +-

.7 *;

.5 l 2.6 009 97 1.0 18.1 +-

3.6 010 120 1.5 17.5 +-

10.2 +-

.7 I 3.5 I

011 131 0.9 18.0 +-

.5 2.7 10.6 +-

.7 I 3.6 012 156 1.1 17.9 +-

.5 I 2.7 10.6 +-

.7 I 3.6 I

013 180 1.1 17.8 +-

.5 2.7 10.5 +-

.7 l 3.6 I

014 194 2.4 18.1 +-

.5 2.7 10.8 +-

.7' 3.6 I

015 201 2.0 17.5 +-

.5 2.6 10.2 +-

.7 I 3.5 016 218 1.2 18.3 +-

.5 I 2.7 11.0 +-

.8 I 3.6 I

017 252 1.1 17.6 +-

.5 2.6 10.2 +-

.7 !

3.5 018 272 1.2 17.6 +-

.5 I 2.6 10.3 +-

.7*

3.6 019 19 1.1 16.2 +-

.5 I 2.4 8.8 +-

.7 I 3.4 3

020 2

1.1 16.7 +-

.5 2.5 9.4 +-

.7 3.5 I

021 288 1.3 15.6 +-

.5 I

2. 3 8.3 +-

.7 I 3.3 022 307 1.5 15.9 +-

.5 I 2.4 8.5 +-

.7 I 3.4 023 338 2.

16.9 +-

.5 I 2.5 9.5 +-

.7 I 3.5 024 325 4.9 15.2 +~

.5 I

2. 3 7.9 +-

.7 I 3.3 025 338 3.8 16.5 +-

.5 3 2.5 9.1 +-

.7 !

3.4 026 356 5.2 16.3 +-

.5 I 2.4 8.9 +-

.7' 3.4 I

027 30 6.4 16.0 +-

.5 2.4 8.6 +-

.7 I 3.4 028 43 9.0 17.3 +-

.5 I I

2.6 10.0 +-

.7 3.5 029 50 8.5 16.3 +-

.5 !

2.4 8.9 +-

.7 3.4 I

030 59 7.2 15.9 +-

.5*

2.4 8.5 +-

.7 3.4 I

031 65 6.5 17.6 +-

.5 I 2.6 10.3 +-

.7 !

3.6 I

032 74 5.8 17.3 +-

.5 2.6 10.0 +-

.7*

3.5

.5 l 2.3

.5 8.2 +-

.7 I 033 88 4.1 15.6 +-

3.3 I

034 12/

17, 17.3 +-

2.6 10.0 +-

.7 3.5 035 16/

18, 15.9 +-

.5 I 2.4 8.6 +-

.7 I 3.4 036 284 15, 16.4 +-

.5 I 2.5 9.1 +-

.7 I

3. 4 037 284 15.

17.9 +-

.5 I 2.7 10.6 +-

.7 I 3.6 0?8 285 15.

16.8 +-

.5 I

.7 l!

3.5 2.5 9.4 +-

.7

.5lI 039 287 4.6 15.1 +-

2.3 7.7 +-

3.3 040 271 0.7 18.0 +-

.5 2.7 10.7 +-

.7 3.6 TRANSIT DOSE =

7.2

+-

.5 ; 2.4

w 15 BRUNSWICK-FOR THE PERIOD 831213-840411 TLD DIRECT RADIATI0tl ENVIR0llHEllTAL M0t11TORit1G RZIMUTH (dog.)

NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.0tr.) t-Std.Dev.

348.75-il.25 (N) 9.2 +

.3 2

11.25-33.75 (NNE) 9.8 +

.?

4 2

33.75-56.25 (NE) 9.5 +

.7 2

56.25-78.75 (ENE) 9.0 +

.9 4

~

78.75-101.25 (C) 9.5 +- 1.0 2

10l.25-123.75(CEE) 19.2 +- 0.0 1

123.75-146.25(SE) 19.5 +- 8.0 1

145.25-155. 75 ( S SE )

le.E 4- 0.0 1

l 1

160.75-131.25(5) 10.2 4-.5 2

i e

191.25-213.75(55H) 10.1 4

.3 3

213.75-236.25 ( GN )

9.5 +- 2.1 2

[

23s.25-2se.7s(HsHi s.4 +- 1.2 a

259.75-201. 25 ( H )

9,2 +- 1.2 5

j 20 L.25-303.75 i HNW)

G,9 += 4 2

i 303.75-326,25(NH) 8,2 +

.5 2

i i

226. 25-34 8.75 ( NNN) 9.9 +

.3 2

d i

l i

i f

4 015TMNCC(me) FROM THC PCACTCP NET HvER.EMPGtuPC PATE 4 IN group t enM / 5 t d. Q t r'. 7 4 -S i d. De v.

B-2 10.0 +

.8 II t-5 0.8 +- 1.8 12 i

,5 UPNINO CONTROL DRin 9.7 +

.0 3

l l

i

16 BYR0l1 TLD DIRECT RADIATI0ti EtlVIR0tlMEllTAL N0t11TORIllG FOR THE PERIOD 831209-840406 119 DAYS FIELD TIME 87 DAYS HRC LOCATI0t1 GROSS tlET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deo.)

(mi.)

+- Rdm

+- Rdm 20.7 +; Tot.

16.9 + ;Tct.

001 10 1.1

.6 3.1

.8 j 3.8

.6 ;;

002 23 1.0 19.5 +-

2.9 15.7 +-

.8 3.7 003 46 1.6 19.2 +-

.6 2.9 15.3 +-

.8 !

3.6 004 68 1.6 20.9 +-

.6 ;

3.1 17.1 +-

.8 3.9

.6 ;

3.2 17.2 +-

.8 *;

005 86 1.4 21.0 +-

006 112 1.3 20.0 +-

.6 ;

3.9 3.0 16.1 +-

.8 !

3.7 007 133 1.4 19.2 +-

.6 I 2.9 15.3 +-

.8*

3.6 008 175 2.2 20.5 +-

.6 I I

3.1 16.7 +-

.8 3.8 009 156 0.6 18.5 +-

.6 l 2.8 14.6 +-

.8 l 3.6 010 183 0.5 20.4 +-

.6*

3.1 16.6 +-

.8 3.8

.6 2.9 15.2 +-

.8 ;

.6 jl 3.1 011 210 0.6 19.0 +-

3.6 3.1 17.0 +-

.8 ;

012 236 0.9 20.8 +-

3.8

.6 16.9 +-

.8 ';

013 247 0.8 20.7 +-

3.8 014 262 0.7 20.4 +-

.6 ',

3.1 16.6 +-

.8 I 3.8 015 298 0.8 20.2 +-

.6 !

3.0 16.4 +-

.8 3.8 I

016 326 1.0 18.9 +-

.6 ;

2.3 15.1 +-

.8l3.6 017 333 1.6 18.7 +-

.6' 2.8 14.8 +-

.8 3.6 018 23 4.0 18.0 +-

.5 I

.7 l 3.5 2.7 14.1 +-

.7 3.5

.5l2.7 13.9 +-

019 17 4.1 17.8 +-

.8 ;;

020 5

4.3 18.9 +-

.6, 2.3 15.0 +-

3.6 021 340 4.2 20.5 +-

.6*

3.1 16.7 +-

.8*

3.8 022 322 4.9 19.0 +-

.6 !

2.9 15.2 +-

.8 I 3.6 023 304 6.9 17.8 +-

.5 !

2.7 13.9 +-

.7 I 3.5 024 270 4.8 18.4 +-

.6 2.3 14.5 +-

.7 I 025 244 4.6 17.5 +-

.5 ';

3.5 2.6 13.6 +-

.7 I 3.4 I

026 224 4.8 20.6 +-

.6 3.1 16.8 +-

.8 3.8 I

.5 I 027 213 5.2 17.0 +-

13.0 +-

.7 I

.5l2.5 3.4 028 209 14 17.1 +-

2.6 13.2 +-

.7 !

3.4 029 215 13.

19.6 +-

.6 2.9 15.7 +-

.8*

3.7

.6l2.6 030 215 13, 21.4 +-

3.2 17.6 +-

.8 !

3.9 031 204 4.6 17.2 +-

.5 13.3 +-

.7*

3.4 032 178 4.4 13.5 +-

.6, 2.3 14.6 +-

.8 1 3.5 033 155 3.9 19.9 +-

.6 I I

3.0 16.1 +-

.8

3. 7

.6 l 3.0 034 138 4.6 19.8 +-

.6 15.9 +-

.8 I 3.7 035 110 4.4 20.7 +-

I 3.1 16.9 +-

.8 3.8 036 81 3.8 18.3 +-

.5 ;

2. 7 14.4 +-

.7 I 3.5 037 70 5.5 17.9 +-

.5 I 2.7 14.0 +-

.7 I 3.5 038 45 4.0 18.5 +-

.6 I 2.3 14.6 +-

.8 I 3.6 I

039 40 6.3 21.0 +-

.6 3.1 17.2 +-

.8 !

3.9 I

040 45 15.

17. 4 + -

.5 2.6 13.5 +-

.7 l*

3.4 041 320 3.0

's.8 +-

.6 !

3.1 17.0 +-

.8 3.8 TRAllsli DOSE =

4.3

.5 ; 2.0

+-

17 BYR0H FOR THE PERIOD 831209-840406 TLD DIRECT RADIATION EINIRONMENTAL MONITORING RZIMUTH (deg.)

NET AVER. EXPOSURE RATE

$ IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-11.25 (N) 18.9 +- 1.4 2

11.25-33.75 (NNE) 14.5 +- 1.0 3

33.75-56.25 (NC) 15.2 +- 1.6 4

4 56.25-78.75 (ENE) 15.5 +- 2.2 2

78.75-108.25 (E) 15.5 +- 2.0 2

10L.25-123.75(ESC) 16.5 +

.5 2

]

123.75-146.25(SC) 15.5 +

.4 2

145.25-155. 75 ( 55E )

15.4 4-1.5 2

155.75-151.25(5) 15.9 4-1.2 3

15L.25-213.75(55W) 13.5 4-1.2 3

213.75-236.25(SW) 16.9 4

.1 2

236.as-25e.75(W9W) 15.2 +- 2.3 2

25e.7s-2et.as(W) 15.5 +- 1.s 2

Isi.2s-3aa.7stwHw)

Is.4 +- s.o i

393,75-328.25(HN) 15.3 +- 1.3 4

i 326.25-349.75(NNN) 15.8 +- 1.4 2

i j

i

}

i 015fMPKE(m e ) TN0H THE PEACTOP HET RVER.CMPOSUPC RATC 4 IN G#ouP i

l ImR/Etd,0tr.7 +-sid.Dev.

8-2 la.1 +

.5 1B 2-5 15.3 +- 1.3 17 1

85 14.3 += 1.6 5

i

{

UPNINO CONTROL OMTA 15.5 +- 2.2 9

i

18 CALLAWAY TLD DIRECT RADI ATI0tl EtlVIR0 tit 1EtlTAL (10NITORIllG FOR THE PERIOD 831213-840412 121 LAYS FIELD TIIIE 91 DAYS HRC LOCATI0tl GROSS tlET EXPO!URE RATE STATION AZIt1UTH/DIST EXPOSURE (mR) mR/St d.0t r.

(deo.)

(mi.)

+- Rdm

+- Rdm 22.3 +; Tot.

18.3 + ; Tot.

001 247 2.1

.7 ;

3.3

.8 ;

3. 9 002 259 1.4 21.4 +-

.6 3.2 17.4 +-

.8 ;

3.8 003 282 1.3 24.4 +-

.7 ;

3.7 20.4 +-

.9*

4.2 004 304 1.3 22.0 +-

.7 I 3.3 18.0 +-

.8 !

3.9 005 330 1.7 21.6 +-

.6 l 3.2 17.6 +-

.8 3.8

.8 ;;

006 1

1.7 20.3 +-

.6' 3.0 16.3 +-

3.6 I

007 23 2

20.7 +-

.6 3.1 16.7 +-

.8*

3.7

.6 l 3.3

.8 l 3.8 008 77

.7 22.3 +-

.7 18.3 +-

3.9 009 85 1.4 21.6 +-

3.2 17.6 +-

.8'

.6' 17.1 +-

.8 !

3.7 010 98 1.5 21.1 +-

.6 l 3.2 011 121 2

20.1 +-

3.0 16.1 +-

.8 3.6

.8 ;;

012 140 2

21.0 +-

.6 '

3.2 17.0 +-

3.7 013 158 2.5 ti!SSIllG OR DAl1 AGED DOS!t1ETER 014 183 3.7 23.6 t-

.7' 3.5 19.5 +-

.8 4.1

.8 l; 3.9 I

015 188 1.7 22.4 +-

.7 3.4 18.4 +-

016 202

.7 21.5 +-

.6 I 3.2 17.5 +-

.8 3.8

.6 l 3.2 017 237

.7 21.0 +-

.6 17.0 +-

.8 3.7

.8 ;

018 312 11 21.5 +-

3.2 17.5 +-

019 292 10 21.7 +-

.6 ';

?.8 I

3.2 17.7 +-

.8 3.8 020 268 9

22.1 +-

.7 l 3.3 18.1 +-

.8 3.9 I

I 021 247 8

22.0 +-

.7' 18.0 +-

.8 3.9

.6 l 3.3 I

022 225 8

20.9 +-

3.1 16.9 +-

.8 3.7 I

023 220 8

22.7 +-

.7' 3.4 18.7 +-

.8 3.9 024 205 5.5 18.9 +-

.6 !

2.3 14.9 +-

.7 I 3.5 025 157 4

22.6 +-

.7' 3.4 18.6 +-

.8 I 3.9 026 134 5

20.2 +-

.6 !

3.0 16.2 +-

.8 !

3.6 027 115 4.2 22.8 +-

.7 ;

3.4 18.8 +-

.8' 4.0

.8 ;l 4.0 028 95 3.5 22.3 +-

.7' 3.3 18.3 +-

.8 3.9

.7l3.4 029 67 3.4 22.9 +-

18.8 +-

030 48 4.5 20.1 +-

.6, 3.0 16.1 +-

.8*

3.6 I

031 14 6.5 22.5 +-

.7' 3.4 18.5 +-

.8 3.9 032 2

5.1 23.1 +-

.7 I 3.5 19.1 +-

.8 I 4.0 033 335 3.6 20.2 +-

.6 !

3.0 16.2 +-

.8 I 3.6 034 288 4.3 23.1 +-

.7 l 3.5 19.1 +-

.8 !

4.0 035 310 5.2 22.2 +-

.7*

3.3 18.2 +-

.8*

3.9 I

I 036 264 3.2 18.7 +-

.6 2.8 14.7 +-

.7 3.5 I

I 037 237 3.0 22.8 +-

.7 3.4 18.8 +-

.8 4.0 038 270 15.

19.4 +-

.6 I I

2.9 15.4 +-

.7 3.5 039 270 15 18.1 +-

.5 I 2.7 14.1 +-

.7 I 3.4 040 203 20 22.0 +-

. 7 !

3. 3 18.0 +-

.8 l 3.9 TRAllSIT DOSE =

3.8

+-

.5 ; 2.1 l

l

{

19 CA'.LAWAY FOR THE PERIOD 831213-840412 TLD DIRECT RADIATI0t1 EtlVIRONMENTAL M0ti!TORING MZIMUTH (deg.)

NET RVER. EXPOSURE RATE 4 IN GROUP (mR/Std Qtr.) t-Std.Dav.

340.75-18.25 (N) 17.7 +- 2.0 2

11.25-33.73 (NNE) 17.5 +- 1.3 2

33.75-56.25 (NE) 16.1 +- 8.0 1

56.25-70.75 (ENEl 10.E +

.4 2

78.75-19L.25 (E)

!?.7 +

.5 3

19 8.25-123.75 ( E SC )

17.5 +- 1.9 2

123.75-146.25(SE) 16.5 +

.5 2

145.25-155.75(SEC) 18.E 4-5.5 1

165.75-151.25(5) 15.5 4

.I 2

194.25-213.75(SEN) 16.2 4-1.5 2

213.75-23G.25 ( SN )

17.B 4-1.3 2

236.25-258.75(WSW) le.B +

.7 4

250.75-201.25(W) 16.7 +- 1.0 3

4 fel.25-393.75(WNW1 19.0 +- 1.4 3

i 393.75-326.25(NN) 17.9 +

.4 3

i 326.25-340.75(NNN) 16.5 +- 1.0 2

?

=

r i

03STANCCin t ) FRON THE RCACTOR PE X

A

+ 1H GROUP 0-2 17.5 += 1.1 14 I-5 17.5 +- 1.6 13 55 17.5 += 1.2 it f

UPHIND CONTROL ORTA 15.I +- 2.0 3

20 CALVERT CLIFFS TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 840117-840413 87 DAYS FIELD TIME 83 DAYS 11RC LOCATI0tl GROSS tlET EXPOSURE RATE STATI0tl AZIt1UTH/DIST EXPOSURE (mR) mR/Std.0tr.

110 llET;Tcit.

+- Rdm (dec.)

(mi.)

+- Rdm; Tot.

DfiTA 001 275 1.5 10.3 +-

.3 '

1.5 3

003 284 1.7 10.6 +-

.3 1.6 tl0 tlET DftTA 004 323 2.4 (11SS!HG OR DAllAGED DOSIMETER 005 297 3.1 10.6 +-

.3 ;

1.6 tl0 NET Df!TA 006 324 4.7 10.6 +-

.3 ;

1.6 110 ilET Df:TA

.3 1.6 N0 ilET DfiTA 007 324 5.5 10.6 +-

.3 ;

1.3 110 tlET DflTA 008 256 6.1 9.0 +-

.3 ;

1.7 t10 ilET DflTA 009 273 4.1 11.4 +-

010 253 3.7 MISSIllGORDAllAGEDDOSINETER l

011 230 4

12.9 +-

.4' 1.9 t10 ilET DfiTA l

012 243 1.3 12.9 +-

.4 !

1.9 t10 ilET DATA l

013 222 1.5 12,7 +-

.4' 1.9 l10 ilET DfiTA

.4 l 1.5

.3 N0 ilET DATA 014 208 1.8 10.1 +-

1.9 l10 ilET Df;TA 015 176 2.4 12.5 +-

016 160 1.5 MIS $ltlG OR DAMAGED DOSIMETER 019 159 1.8 IIIS$ltlG OR DAMAGED 00$1 HETER l

020 139 4.7 9.5 +-

.3' 1.4 110 flET DfiTA I

021 201 4

11.5 +-

.3 1.7 110 llET Df!TA I

tl0 tlET DATA

.3 l 1.7 022 187 4.7 11.0 +-

.4 1.3 t10 i1ET DATA l

023 201 8.7 12.1 +-

.3' fl0 llET DATA 024 190 7.8 9.8 +-

.3 l 1.5 1.7 t10 tiET DATA 025 325 6.7 11.0 +-

026 314 10.

10.6 +-

.3 ;

1.6 110 NET DATA 027 314 10.

11.3 +-

.3 ;

1.7 t10 t1ET DATA 028 315 10.

11.6 +-

.3*

1.7 l10 ilET DATA 029 186 11.

HISSINGORDAllAGEDLOS! HETER tl0 TRAtlSIT DOSE CALCULATED (TLD CONTROLS HIS$1HG OR OTHERll!!E fl0i COMPLETE) 1

m 21 CALVERT CLIFFS FOR THE PERIOD 840117-940413 TLD DIRECT RADIATION ENVIRONMENTAL MONITORDIG AZ D1UTH (deg.)

AVER. EXPOSURE RATE

$ Iti GROUP (mR/Std.0tr.) +-Std.Dev.

340.75-11.25 (ii)

NO DATA +-tJO DATA 0

11.25-33.75

( title )

NO D ATA*-740 DAT A 0

33,75-56.25

( tJ E )

NO DRTA*-t40 DATA 0

56.25-78.75

( Et4E )

No DATR+-t40 DATA 0

78.75-101.25 (E)

NO DATA *-t10 DATA 0

101.25-123.75(ESE)

NO DATA *-tio DATA 0

123,75-146.25(SE) 9.9 +- 0.0 1

146.25-160.75(55E)

NO DATR&-f40 DRTA 0

160.75-191.25(5) 11.5 4-1.4 3

194.25-213.75(55H)

It.6 +- 1.1 3

213.75-236.25(SN) 13.2 4-

.1 2

236.25-250.75(11561)

IL.3 +- 2.0 2

250.75-201.25(61)

!!.2 +

.0 2

201.25-303. 75 ( 64 tlli) 10.9 +

.0 2

3 03.75-326. 25 ( tiH )

!l.1 +

.3 3

i 32 6. 25 -3 4 9. 75 ( tifiH )

No DATA +-tio DATA 0

1 1

DISTAtJCC(mt) FHott THE REACfoP AVER.EAPOSUPE PATC

+ Ill GROUP (nR/Std,0tr.; + -5 t d. De v,

Q-2 16.7 +- 1.4 5

~

2-5 18.6 +- 1.1 0

85 10.8 +- 1.2 5

UPHIt40 Cot 4 TROL DATA 1L.B +

.5 3

L

22 CATAWEA i

TLD DIRECT RADIATION EllVIR0tir1EllTAL MONITORIt1G FOR THE PERIOD 831214-840504 142 DAYS t

FIELD T! TIE 92 DAYS tlRC LOCATION GROSS tlET EXP05URE RATE STATION AZIllVTH/DIST EXPOSURE (mR) mR/Std.0tr.

(deo.)

(mi.)

+- Rdm

+- Rdm 24.0 +; Tot.

11.5 + ; Tcit.

001 134 0.1

.7 ;

?.6

.9 ;

4.6 002 162 0.4 22.6 +-

.7 ;

3.4 10.2 +-

.8 ;

4.5 003 132 0.8 22.7 +-

.7 3.4 10.2 +-

.8 4.5 004 111 1.3 23.3 +-

.7 *;

.8 ;;

3.5 10.8 +-

4.5 005 045 0.7 MISSIf4GORDAkAGEDDOSItlETER 006 293 1.3 24.7 +-

.7 3.7 12.2 +-

.9 4.7

.7 ;;

.8 ;;

007 004 0.6 22.8 +-

3.4 10.4 +-

4.5 008 332 1.5 27.2 +-

.8 4.1 14.6 +-

.9 5.0

.6 ;

.8 ;;

009 318 1.6 20.4 t-3.1 8.0 +-

4.2 010 176 1.8 26.4 +-

.8 ;

4.0 13.9 +-

.9' 4.9 011 203 1.5 24.8 +-

.7 ;

.9 l 4.7 3.7 12.3 +-

.9

.8 ;;

012 225 1.5 26.1 +-

3.9 13.6 +-

4.9

.8 ;

013 250 1.9 22.5 +-

.7 3.4 10.1 +-

.6 ;;

4.5

.8 ;;

014 270 1.4 20.5 +-

3.1 8.1 +-

4.2 015 331 3.0 20.6 +-

.6 ;

3.1 8.2 +-

.8' 4.3 4,g g4,c,-

.8 l 4.3 016 311 3.9 21.3 +-

.6 *

3. 2 '

8.8 +

017 296 9.5 27.2 +-

.8 1

,9 5.0

.8 l 3.2 i

018 324 4.8 26.2 +-

I 3.9 13.7 +-

.9 4.9

.8 l 4.6 019 352 4.8 21.2 +-

.6 '

8.8 +-

4.3

)

020 022 4.0 24.1 +-

.7 I 3.6 11.6 +-

.9.8 ;

.7 ;l 3.3 021 290 3.9 21.7 +-

.6

?.2 9.2 +-

4.4 9.5 +-

.8 l 4.4 022 266

4. 0 21.9 +-

023 251 4.0 19.1 +-

.6 '

2.9 6.7 +-

I

.8 4.1 024 229 3.9 19.3 +-

.6 2.9 6.9 +-

.8 ;

4.1

.9 ;;

.8 l 3.8 025 202 4.4 25.2 +-

.8 12.7 +-

4.8 026 051 4.3 25.4 +-

3.8 12.9 +-

.9' 4.8

.6 ;

I 027 064 7.9 19.6 +-

2.9 7.2 +-

.8 4.1 028 061 4.9 23.3 +-

.7 ;

I 3.5 10.8 +-

.9 4.5 029 049 1.9 22.5 +-

.7 ;

I 3.4 10.1 +-

.8 4.5

.6 ;

I 030 064 1.8 21.2 +-

.7 l 3.2 8.8 +-

.8 4.3 I

031 087 1.6 21.8 +-

3.3 9.3 +-

.8 4.4 I

032 121 2.6 20.7 +-

.6*

3.1 8.2 +-

.8 4.3 033 114 7.6 20.6 +-

.6 !

3.1 8.2 +-

.8 I 4.2 I

034 093 4.5 22.8 +-

.7 ;

3.4 10.4 +-

.8 4.5 035 132 4.3 26.9 +-

.8*

4.0 14.3 +-

.9 I 4.9 I

I 036 163 8.9 19.5 +-

.6 2.9 7.1 +-

.8 4.1 I

I 037 173 4.9 19.8 +-

.6 3.0 7.4 +-

.8 4.2 I

038 157 4.6 23.7 +-

.7 3.6 11.2 +-

.9 I 4.6 I

I 039 248 10, 22.7 +-

.7 3.4 10.3 +-

.8 4.5 040 229 12.

19.2 +-

.6 l 2.9 6.8 +-

.8 I 4.1 I

041 218 13.

20.1 +-

.6

  • 7.7 +-

.6 l 3.0

.8 l 4.2 042 213 16.

20.7 +-

3.1 8.3 +-

.8 4.3 TRANSIT D05E =

12.2

+-

.5 ; 3.1 I

23 CATAWBA r

FOR THE PERIOD 831214-840504 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING AZDIUTH (dug. )

NET RVER. EXPOSURE RATE 4 2N GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-il.25 (N) 9.6 +- 1.1 2

11.25-33.75 (NNE)

!!.E +- B.O 1

33.75-56.EJ (NE) 11.5 +- 2.0 2

56.25-78.75 (ENE) 9.0 +- 1.5 3

78.75-101.25 (E) 9.8 +

.7 2

19L.25-123.75(ESE) 9.1 +- 1.5 3

123.75-146.25(SC) 12.9 +- 2.1 3

146.25-168. 75 ( 55E )

9.5 4-2.2 3

168.75-191.25(5)

IB.E 4-4.6 2

151.25-2L3.75(55H) 12.5 4-.3 2

213.75-236.25(SN) 10.2 4-4.7 2

236.25-258.75(W5W) 9.9 +- 2.9 3

258 '15-281.25(W) 8.8 +- 1.B 2

281.25-393.75(WNW) 12.B +- 2.7 3

303.75-326.25(NH)

10. 2 +- 3.1 3

I a26,25-348.75(NNN) 11.4 +- 4.5 2

q 2

03GTANCE(mt) FROH THE PCACTOP PET RVER.E APOSURE PHTE 4 2N GROUP

( rnR/ 6td Q t r. ) +-5td.Dav.

B-2 10.9 +- 2.0 15 2-5 10.1 +- 2. 4 17

$5 9.5 +- 3.1 5

UPN!ND CONTROL 0FiTA 7.6 +~.8 3

l l

\\

i 5

2, 24 CLINTON TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831209-840406 119 DAYS FIELD TIME

-87 DAYS NRC LOCATION GROSS.

NET EXF05URE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr..

(dea.)

(mi.)

+.Rdm; Tot.-

18.9 + ; Tot.

+- Rdm 001 352 0.6 21.7 +-

.7 ;

3.3

.8 4.0

.8 ;

002 7-0.7 21.8 +-

.7 3.3 19.0 +-

4.0

.7 ;

.9 ;

003 26 0.8 24.4 +-

3.7 21.6 +-

4.4

.7 ;

.8 ;;

004 165 0.5 21.9 +-

3.3 19.1 +-

4.0L

.6 ;

005 187 0.5 21.5 +-

3. ~2 18.7 +-

.8 ;

4.0

.7 ;

006 223 0.6 22.6 +-

3.4 19.8 +-

.9 ;

4.1

.6 ;

007 238 0.8 21.7 +-

3.2 18.9 +-

.8 ;

4.0

.7 ;;

008 62 1.9 22.2 +-

3.3 19.4 +-

.8 4.1

.8 ;

009 78 1.8 22.1 +-

.7 ;

3.3 19.3 + -

4.1

.8 ;

010 79 2.6 22.3 +-

.7 ;

3.3 19.5 +-

4.1

.8 ;

011 104 2.3 21.9 +-

.7 ;

3.3 19.1 +-

4.0

.8 ;

012 115 3.0 20.8 +-

.6 ;

3.1 17.9 +-

3.9

.8 ;;

013 127 3.2 21.4 + -

.6 3.2 18.6 +--

4.0

.7 ;

014 160 2.1 21.8 +-

3.3 19.0 +-

.8 4.0

.7 ;

.9 ;

015 180 3.0 23.4 +-

3.5 20.6 +-

4.2

.7 ;;

.9 ;

016 203 3.2 22.4 +-

3.4 19.6 +-

4.1

.8 ;

017 235 3.7 19.6 +-

.6 ;

2.9 16.7 +-

3.7 018 255 2.8 20.7 +-

.6 ;

3.1 17.8 +-

.8 ;.3.9 019 275 2.3 22.2 +-

.7 ;

3.3 19.4 +-

.8 ;

4.1 020 302 0.9 19.1 +-

.6 ;

2.9 16.2 +-

.8 3.7

-.9 021 305 0.8 22.4 +-

.7 ;

3.4 19.6 +-

4.1 1.0 ;

022 332 0.6 28.1 +-

.8

  • 4.2 25.5 +-

4.9 023 358 4.6 MISSINGORDAbAGEDDOSIMETER 024 20 3.9 22.6 +-

.7 ;

3.4 19.8 +-

.9 ;

4.1 025 46 5.0 22.9 +-

.7 ;

3.4 20.1 +-

.9 ;

4.2 026 62 5.5 21.8 +-

.7 ;

3.3 19.0 +-

.8 4.0 027 90 4.8 21.2 +-

.6 ;

3.2 18.3 +-

.8 ;

3.9

.8 ;

028 115 5.2 20.3 +-

.6 3.0 17.4 +-

3.8

.6 ;;

.8 ;

029 128 5.1 21.5 +-

3. 2 '

18.7 +-

4.0

.8 ;;

030 153 5.8 21.8 +-

.7 ;

3.3 19.0 +-

4.0 031 173 5.2 21.8 +-

.7 ;

3.3 19.0 +-

.8 ;

4.0 032 205 4.7 21.7 +-

.6 ;

3.2 18.9 +-

.8 4.0

.8 ;

033 236 5.4 21.3 +-

.6 ;

3.2 18.5 +-

4.0

.8 ;

034 252 5.8 22.3 +-

.7 ;

3.3 19.5 +-

4.1

.8 ;

035 263 6.6 19.4 +-

.6 ;

2.9 16.5 +-

3.7 036 272 4.8 19.7 +-

.6 ;

3.0 16.8 +-

.8 ;

3.7

.9 ;

037 288 4.8 22.5 +-

.7 3.4 19.7 +-

4.1

.6 ;

.8 ;;

038 297 7.6 20.0 +-

3.0 17.1 +-

3.8

.7 ;;

039 315 5.1 21.7 +-

3.3 18.9 +-

.8 ;

4.0 040 342 4.3 21.9 +-

.7 3.3 19.1 +-

.8 4.0

.6 ;;

.8 ;;

041 65/

10.

20.6 +-

3.1 17.7 +-

3.9 042 148 13.

25.9 +-

.8 ;

3.9 23.3 +-

.9 ;

4.6 043 148 13.

25.6 +-

.8 3.8 22.9 +-

.9 ;

4.5

.6 ;;

044 206 15.

19.9 +-

3.0 17.0 +-

.8 ;

3.8 TRANSIT DOSE =

3.4

+-

.5 ; 2.1 r

?

25

- CLINTON '.

o

FOR THE PERIOD'831209-840406 TLD DIRECT RADIATION ENVIRONMENTAL' MONITORING RZIMUTH (dog.)

NET AYER.' EXPOSURE' RATE 4-IN GROUP

-(mR/Std.Qtr.) +-Std. Dew.

s j

348.75-1L.25 (N)-

19.8'+

.1-2-

~11.25-33.75 (NNE)

.20.7 +- 1.3 2

33.75-56.25- (NE) 20.1 +- 8.0

'l 56.25-78.75 (ENE)

18.9 +-.B 4

78.75-10l. 25 '(E) 18.5 +

.B 2

101.25-123.75(ESE) 18.1 +

.5 3

j 123.75.146.25(SE).

18.B +-.1-2-

145.25-158.75(55E) 19.8 +

.1 3

i 158 ~.75-191.25 ( 5 )

19.4 4-1.0 3

191.25-2l3.75(55N) 19.2 4-.5 2

213.75-236.25(SN) 19.3~.+- 1.6 3

236.25-258.75(WSW) 18.7 +

.9 3

4 258.75-281.25(W) 17.8 +- 1.6 3

4 281.25-303.75 (WNW )

17.7 +

1.8-3 1

303.75-326.25(NN) 19.3 +

.5 2

326.25-348.75(NNN) 22.3 +- 4.5 2

1 i

i l

DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP l

( rnR/ 5t d. Q t r. ) - +-5t d. De v.

8-2 19.7 +- 2.2' 12 2-5 18.5 +- 1.1 17

> 5 --

18.3 +- 1.0 11 LJPNIND CONTROL DRTA 2l.1 +- 3.5 3

f

26 C0HANCHE PK.

. TLD DIRECT RADIATI0li EN'v'IRONMENTAL MONITORING i

FOR THE PERIOD 831208-840412 126 DAYS 1

FIELD TIME.

91 DAYS NRC LOCATION GROSS tlET EXPOSURE RATE STATION AZIMUTH /DIST.

EXf050RE(mR) mR/Std.Qtr.

(dea.)

(mi.)

+- Rdm; Tot.

15. 9 + ; Tcit.

+- Rdm 001 306 1.4 20.3 +-

.6 ;. 3.0

.7; 3.5 002 285

-1. 5

16. 8 + -

.5 ;

2.5 12.4 +-

.7 ;

3.1 003 268 1.1 17.6.+-

.5 2.6 13.2 +-

.7 ;

3.2

.6 ;;

004 253

.9 19.2 +-

2.9 14.8 +-

.7 ;

3.4 006 200 1

17.3 + -

.5 2.6 12.9 +-

.7 3.2

.7 ;;

.5 ;;

007 180 1.4 18.1 +-

2.7 13.7 +-

3.3 008 163 1.6 20.0 +--

.6 ;

3.0

.15.6 +-

.7 ;

3.5 009 140 1.3 20.6 +-

.6 3.1 16.2 +-

.7 ;

3.6

.5 ;;

010 118 1.5 16.6 +-

2.5 12.2 +-

.7 3.1

.7 ;

011 93 1.9 16.9 +-

.5 ;

2.5 12.5 +-

3.1 '

.8 ;

012 73 2.4 22.7 +-

.7 ;

3.4 18.2 +-

3.9

.7 ;

013 245 1.7 17.9 +-

.5.

2.7 13.5 +-'

3.3

.6 ;

.7 ;

014 156 4.3 19.5 +-

2.9 15.1 +-

3.5 015 186 7-18.7 +-

.6 ;

.7 ;

2.8 14.3 +-

3.4

.6 ;;

.7 ;

016 183 4.1 19.1 +-

2.9 14.7 +-

3.4

.7 ;

017 205 4.3 19.6 +-

.6 ;

2.9 15.2 +--

3.5

.7 ;;

018 225 3.4 16.9 +-

.5 ;

2.5 12.5 +-

3.1 019 245 5.2 19.2 +-

.6 2.9 14.8 +-

.7 ;

3.4

.5';

020 264 5.8 17.0 v-2.5 12.6 +-

.7 ;

3.1 021 258 3.2 17.6 +-

.5 ;

2.6-13.2 +-

.7 ;

3.2

.5 ;

022 284 5.1 16.6 +-

2.5 12.2 +-

.7 3.1

.5 ;;

2.7

.7 ;;

023 313 5.8 18.2 +-

13.8 +-

3.3 024 332 4.9 18.0 +-

.5 ;

2.7 13.6 +-

.7 ;

3.3 025 9

4.6 18.6 +-

.6 ;

2.8 14.2 +-

.7 ;

3.3 026 26 4.5 18.8 +-

.6 ;

2.8 14.4 +-

.7 ;

3.4 027 47 4.1 18.0 +-

.5 ;

2.7 13.6 +-

.7 ;

3.3 028 6

1.8 MISSING OR DAMAGED DOSIMETER 029 16 1.9 18.8 +-

.6 ;

2.8 14.4 +-

.7 ;

3.4 030 102 3

19.5 +-

.6 2.9 15.1 +-

.7 ;

3.5

.5 ;

031 108 3.9 18.2 +-

2.7 13.8 +-

.7 ;

3.3.

.6 ;

032 135 4.6 19.4 +-

2.9 15.0 +-

.7 3.4

.5 ;

.7 ;

033 152 6.3 18.1 +-

2.7 13.7 +-

3.3

.5 ;

.6 ;

034 47 2.9 16.0 +-

2.4 11.6 +-

3.0

.5 ;

.7 ;

035 85 4.8 18.3 +-

2.7 13.9 +-

3.3

.6 ;

.7 ;;

036 115 7.5 18.5 +-

2.8 14.1 +-

3.3 037 355 9.4 18.2 +-

.5 ;

2.7 13.8 +-

.7 ;

3.3

.5 ;

038 337 9.2 18.3 +-

2.7 13.9 +-

.7 ;

3.3

.6 ;

039 310 9.9 19.1 +-

2.9 14.7 +-

.7 3.4

.5 ;;

.7 ;;

040 302 8.1 17.5 +-

2.6 13.1 +-

3.2 041 248 7.9 19.6 +-

.6 ;

2.9 15.2 +-

.7 ;

3.5 042 90

.5 16.1 +-

.5 ;

2.4 11.8 +-

.6 ;

3.0 043 18 9.8 19.3 +-

.6 ;

2.9 14.9 +-

.7 ;

3.4 044 263 1.7 16.3 +-

.5 ;

2.4 11.9 +-

.6 ;

3.1 045 218 12.

19.0 +-

.6 ;

2.9 14.6 +-

.7 ;

3.4 046 140 12.

18.7 +-

.6 ;

2.8 14.3 +-

.7 ;

3.4 047 301 21.

19.7 +-

.6 ;

2.9 15.3 +-

.7 ;

3.5 TRANSIT DOSE =

4.2

+-

.4 ; 1.9

27 COMANCHE PK.

FOR THE PERIOD 831208-840412 TLD DIRECT RADIATION ENVIRONMENTAL HONITORING AZU1UTH (dag.)

NET RVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qir.) t-Std.Dav.

348.75-11.25'(N) 14.0 +

.3 2

11.25-33.75 (NNE) 14.6 +

.3 3

33.75-56.25 (NE) 42.6 +- 1.4 2

56.25-78.75 (ENE) 38.2 +- B.O 1

78.75-101.25 (E)

12. 7 +3 1.1 3

10l.25-123.75(ESE) 13.B +- 1.2 4

123.75-146.25(SE) 15.2 +- 1.0 3

145.25-158.75(55E) 14.8 +- 1.0 3

158.75-191.25(5) 14.2 4-.5 3

191.25-213.75(55H) 14.1 +- 1.5 2

213.75-23G.25(SN) 13.6 4-1.5 2

236.25-258.75(W5H) 14.3 +

.9 5

258.75-281.25(W) 12.6 +

.6 3

281.25-303.75(WNW) 13.3 +- 1.4 4

303.75-328.25(NH) 14.8 +- 1.0 3

326.25-348.75(NNN) 13.8 +

.2 2

DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/Std Qtr.) +-5t d. De v.

(

B-2 13.5 +- 1.5 14 2-5 14.3 +- 1.5 15

>5 14.1 +

.9 16 UPHIND CONTROL DATA NO DATA NO DATA

28 D.C. COOK TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831212-840420 130 DAYS FIELD TIME 92 DAYS HRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/St d. Qt r.

(deg.)

(mi.)

+- Rdm; Tot.

+- Rdm N0 NET;Tcit.

001 54 1.7 18.2 +-

.5 2.7 DflTA

.6 ;

002 67 1.3 19.4 +-

2.9 N0 NET DflTA 003-89 1.1 18.0 +-

.5 ;

2.7 HO NET DflTA 004 58 0.7 17.9 +-

.5 ;

2.7 NO NET DflTA

.6 ;;

005 19 2.3 18.5 +-

2.8 NO NET DflTA 006 111 1.6 18.6 +-

.6 ;

2.8 NO NET DflTA 007 135 1.5 18.8 +-

.6 2.8 HO NET Df!TA

.6 ;

008 158 1.4 18.9 +-

2.8 NO NET DflTA

.5 ;;

009 171 1.9 16.8 +-

2.5 NO NET DflTA 010 199 1.5 17.6 +-

.5-2.6 N0 NET DflTA 011 195 3.9 MISSINGORDAbAGED. DOSIMETER 012 200 6.6 18.7 +-

.6 2.8 NO NET DflTA

.6 ;;

013 179 3.9 20.2 +-

3.0 N0 NET DfiTA 014 151 4.4 20.4 +-

.6 ;

3.1 N0 flET DflTA 015 130 4.6 20.9 +-

.6 ;

3.1 NO NET DflTA 016 110 3.7 19.0 +-

.6 ;

2.9 N0 NET DflTA 017 88 3.6 18.6 +-

.6

  • 2.8 N0 flET DflTA 018 67 3.8 MISSINGORDAbAGEDDOSIMETER 019 24 3.8 18.3 +-

.5 ;

2.7 HO NET Df!TA 020 43 3.3 20.5 +-

.6 ;

3.1 NO HET DflTA 021 26 9.9 22.3 +-

.7 3.3 NO NET DflTA

.6 ;;

022 121 18.

19.1 +-

2.9 N0 NET Df!TA 023 121 18.

18.5 +-

.6 ;

2.8 NO NET DflTA 024.

121 18.

20.6 +-

.6 3.1 NO NET DflTA NO TRANSIT DOSE CALCULATED (TLD CONTROLS; MISSING OR OTHERWISE NOT C

p r

- D.C; COOK-FOR THE PERIOD.831212-840420 Tl.D DIRECT RADIATION ENVIRONMENTAL MONITORING' RZIMUTH l(dog.')

_ JRVER. EXPOSURE RATE i4 IN GROUP (mR/Std.Qtr.) t-Std.Dav.

34L.75-1 L. 25 - (N)-

No DRTR+-NO DATR

'8 11.25-33.75 (NNE).

13.B.+- 1.6 13 :

)

33.75-56.25 (NE) 13.4 +- 1.1 2

56.25-78.75 (ENE).

-12.9 +

.7.

2-i 78.75-101.25 (E) 12.7 +

.3 2

}

101.25-123.75(ESE) 13.B.+

.2 2

123.75-146.25(SE) 13.7 +- 1.1 2

145.25-158.75 ( 55E) 13.5 +

.7

-2 158.75-191.25(5) 12.B +-'1.7 2

i-191.25-2t3.75(55N)-

12.5 4-

.5 2

i 213.75-236.25(SW)

NO DRTA+-NO DATR 0

236.25-258.75(HSH)

NO DRTRt-NO DATR

'G

[

f 258.75-281.25(H)

No DRTRt-NO DATR G

f l

28L.25-303.75(HNH)

No DRTRt-NO DATR S

303.75-326.25(NN)

No DRTRt-NO DATR G

326.25-348.75(NNN)

NO DATR+-NO DATR 8

t 4

i i

i i

l-DISTANCE (mi) FROM THE REACTOR RVER. EXPOSURE RATE

+ IN GROUP I

(mR/5td, Qtr. ) +-5t d. De v,

B-2 12.E +

.5 9

l 2-5 13.5 +

.7 8

>5 14.2 +- 1.8 2

UPNIND CONTROL DATA 13.4 +

.7 3

i

l30 COOPER' 1TLD DIRECT RADIATION ENVIRONMENTAL MONITORING-FOR THE PERIOD 831208-840417-131 DAYS FIELD 1 TIME 99 DAYS' NRC LOCATION GROSS NET EXPOSURE RATE STATION-AZIMUTH /DIST' EXPOSURE (mR) mR/Std.0tr.

-(dea.)

(mi.)

+ fRdm; Tot.

HO NET;Tct.

+- Rdm

001 363 2.4 24.4 +-

.7 3.7 DATA.

.8:;:

002 6

3.5.

25.7 +-

3.9 HO NET DATA

.8 ;

3.9

'HO NET DflTA 003-18 2.7 26.1 +-

.8 ;;

004 16 3.2

'26. 3 +-

3.9 N0 i1ET DATA 005 47 1.9 26.2 +-

.8 ;

3. 9 '

NO NET DfTA 006 40

3. 6 -

24.7 +-

.7 ;

3.7 NO NET Df1TA 00<

(5 2.7.

'25.2 +-

.8 ;

3. 8 -

N0 NET DfiTA 008 55 2.8-25.9 +-

.8 3.9 HO NET DfiTA

.8 ;

009 80 2.1-

-27.6 +-

4.1 NO NET DflTA 010 98 3.7 25.7 +-

.8 ;~ 3.9

.8 HO NET DfiTA All 118 2.3L 26.1 + -

3.9 NO NET - DfiTfi 012

.109 4.6 26.7 +-

.8 ; ' 4.0 NO NET Df1TA '

-013 141

~3.0 07.1 +-

.8 ;

4.1-NO NET DfiTA '

014 126.

5.6

~24.9 +-

.- 7 ;

3.7

'N0 NET Df1TA 1

015 159

-2.7 25.7 +-

.8 3.9 NO NET DATA

.8 ;

016 167 4.9 26.6 +-

4.0

'll0 NET DfiTA

.8 ;

017 205 a0. 3 25.5 +-

3.8 NO NET DATA

.8 ;

018 186 4.7 26.8 +-

4.0 NO NET DATA'

.8 ;

019 213 3.0 25.7 +-

3.3

-NO NET DATA 020 195 4.9 27.0 +-

.8 4.0 NO NET DATA

.7 ;;

021 222 2.0 24.7 +-

3.7 NO NET DfiTA 022 215 5.7 27.8 +-

.8 ;

4.2 NO HET'DfiTA 023 256 1.5 26.9 +-

.8 )

4.0 NO NET DATA 024 238

-5.2 27.2 +-

.8 ;

4.1 NO NET DATA 025 276 2.0 07.5 +-

.8 ;

4.1 NO NET DflTA 026 260 3.8 27.1 +-

.8 ;

4.1 NO NET DATA 027 301 1.8 25.7 +-

.8 ;

3.8 HO NET DfiTA-028 286 4.3 26.7 +-

.8 ;

4.0 NO NET DATA 029 324 2.8 25.8 +-

.8 ;

3.9 N0 NET DATA 030 333 3.7 26.0 +-

.8 ;

3.9 N0 NET DATA 031 343 2.6 27.3 +-

.8 ;

4.1 NO NET DATA 032 333 3.7 26.0 +-

.8 ;

3.)

NO NET DATA 031 015 1.0 25.3 +-

.8 ;

3.3 NO NET DATA 034 173 18.

27.0 +-

.8 ;

4.0 NO NET DATA 035 333 23.

25.0 +-

.7 ;

3.7 NO NET DATA 036 210 19.

25.7 +-

.8 3.9 NO NET DATA

.9 ;;

037 64 7.0 29.8 +-

4.5 NO HET DfiTA 038 329 9.0 26.0 +-

.8 l 3.9 N0 NET DATA 039 276 10.

MISSING OR DAMAGED DOSIMETER 040 300 2.5 26.7 +-

.8 ;

4.0 NO NET DATA 042 93 3.5 25.0 +-

.8 3.8 NO NET DATA

.8 ;

3.9 NO NET DATA 043 270 2.2 25.7 +-

NO TRANSIT DOSE CALCULATED (TLD CONTROLS; MISSING OR OTHERNISE NOT CO i

i

31 COOPER

-FOR THE PERIOD 831208-840417 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RIU1UTH (dog.)

RVER. EXPOSURE RRTE 4'IN GROUP (mR/Std.Qtr.) +-Std.Dev.

~340.75-11.25 (N)

L7.2 +

.6 2

11.25-33.75 (NNE) 15.5 t-

.1 2

.32.75-5G.25 (NE) 17.G +

.5 3

56.25-78.75 (ENE)

18. 9 +- 2. 2 -

2 78.75-l 01.25. (E) l?.9 +

.S 3

101.25-123.75(ESE)

LB.! +

.3 2

123.75-146.25(SE) 17.9 +- 1.l 2

145.25-155.75(55E) 15.8 +-

.4 2

IEB.75-191.25(E)

LB.4 +- B.B 3

ISL.25-213.75(SSN)

L7.9 +

.6 3

213.75-236.25(SN) l7.8 +- 1.l 3

236.25-258.75(NSN) 18.6 +

.1 2

230.75-281.25(W) 18.4 +

.6 3

28L.25-303.75(HNH)

LB.t +-

.4 3

353.75-32E.25(NH) 17.7 +- B.B I

22G.25-34Q.75(NNH) 19.L +-.5 4

i DISTANCE (mt) FROM THE REACTOR AVER. EXPOSURE RATE f IN GROUP (mR/Std.Ctr.) +-Std.Dev.

l B-2 l?.? +

.5 S

i l

2-5 LB.O +

.6 27 l

>5 LB.6 +- 1.3 5

UPHIND CONTROL DRTM 17.5 t-

.7 3

l

i 1

s 32-CRYSTAL RIVER'

]

TLD DIRECT RADIATION ENVIRONMENTAL MONITORING' j

,FOR THE-PERIOD 831213-840412 121 DAYS t

FIELD TIME 99 DAYS i

flRC LOCATION GROSS IlET EXPOSURE-RATE.

STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deg.)

(mi.)

+- Rdm; Tot.

+- Rdm 11.6 + ; Tot.

006 61 4.2 16.5.+-

.5 2.5

.6 2.9

.5 ;;

.6 ;;

007 50 3.8 15.2 +-

2.3-10.5 +-:

2.8 008 20 5.2.

-15.7 +-

.5 2.3 10.9 +--

.6 2.9-

.5 ;;

.7 ;

009 6

5.4 18.0 +-

2.7 13.0-+-

3.1

.5 2.4 10.9 +-

.6 ;

010 348 5.0 15.7 +-

2.9

.5-;;

. 7 ;;

011 334 4.8 17.4 +-

2.6 12.5 +-

3.0 012 318 4.8 16.2 +-

.5 2.4 11.3 +-

.6 ;

2.9

.5 ;;

013 79 3.8 16.5 +-

2.5 11.6 +-

.6 2.9

.7 ;;

014 95 4.1 17.4 +-

.5-2.6 12.4 +-

3.0 015 89 1.8 MISSINGORDAbAGEDDOSIMETER 016 113 5.0 MISSING OR DAMAGED DOSIMETER 017 133 5.5

~ 5.3 +-

.5 10.6 +-

.6 2.8 1

.5 ;- 2.3

.6 ;

018 74 8.1 16.1 +-

2.4 11.2 + -

2.9

.5 ;;

.6; 019 127 7.6 17.2 +-

2.6 12.2 +-

3.0

.6 ;;

020 150 12.

15.7 +-

.5 -

2.4 10.9 +-

2.9 021 159 13.

MISSINGORDAb8GEDDOSIMETER 022 150 20.

15.9 +-

.5 2.4 11.1 +-

.6 2.9

.4 ;

.6 ;;

023 150 20.

14.1 +-

2.1 9.4 +-

2.7

.4 ;

024 150 20.

14.8 +-

2.2 10.1 +-

.6 ;

2R 025 56

.6.1 16.5 +-

.5 ;

2.5 11.6 +-

.6 2.9

.6 ;; '2.8

.7 ;;

026 357 5.2 18.5 +-

13.5 +-

3.2 027 90/

13.

15.7 +-

.5 ;

2.3

'10.9 +-

.6 ;

2.9 028' 140 4.8

. 16.5 +-

.5 ;

2.5 11.6 +-

.6 ;

2.9 TRANSIT DOSE =

3.7 +-

.5 ; 2.1

33 CRYSTAL RIVER FOR THE PERIOD 831213-840412 TLD DIRECT RADIATION ENVIRONMENTHL MONITORING RZIMUTH (dag. )

NET RVER. EXPOSURE RATE 4 IN G90UP (mR/Std.Otr.) +-Std.Dav.

348.75-11.25 (N) 13.2 +

.4 2

11.25-33.75 (NNE) 10.9 +- B.O 1

33.75-56.25 (NE) ll.1 +

.B 2

56.25-78.75 (ENE) 11.4 +.3 2

78.75-10l.25 (E)

!l.6 +

.B 3

101.25-123.75(ESE)

NO DATR+-NO DATR 0

123.75-146.25(SE) 11.5 +

.S 3

145.25-168.75 ( 55E )

10.9 +- B.O 1

158.75-191.25(5)

NO DRTR+-NO DRTR B

191.25-213.75(55N)

NO DRTR+-NO DRTR 8

213.75-236.25(SW)

NO DATA +-NO DATR 0

236,25-258. 75 ( WSW )

NO DATAt-NO DATR G

258.75-281.25 ( W )

NO DATRt-NO DATR G

28l.25-303.75(WNW)

NO DATRt-NO DATR G

303.75-326.25(NN) 11.3 +- G.O 1

326.25-348.75(NNN) 11.7 +- 1.1 2

1 DISTRIJCE(mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/5td,Qtr.) +-Std.Dev, 9-2 NO DATRt-NO DATR S

2-5 11.6 +

.7 8

>5 ll.B +- 1.0 9

UPNIND CONTROL DATA 10.2 +

.B 3

l l

l

34 DPNIS BESSE

'TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831209-840425 138-DAYS FIELD TIME 95 DAYS l

i NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.

(deg.)

(mi.)

+- Rdm; Tot.

+- Rdm 10.1 + ; Tot.

001 50 0.6 19.4 +-

.6 2.9

.8-3.7 002 86 0.9 21.0 +-

.6 ;

.8 ;;

3.2 11.6 +-

003 116 1.4 20.3 +-

.6 ;

3.9 3.0 10.9 +-

.8 3.8 004 172 0.8 22.6 +-

.7 ;

.8 ;

3.4 13.1 +--

005 200 1.5 26.3 +-

.8 ;

4.0

.9 ;

3.9 16.6 +-

4.5

.8 ;

.9 ;

006 226 1.0 25.5 +-

3.8 15.8 +-

.7 ;

4.4

.9 ;;

007 249 1.5 23.5 +-

3.5 14.0 +-

4.2 008 267 1.8 26.0 +-

.8 ;

3.9 16.4 +-

.9 4.4 009 285 1.8 24.6 +-

.7 ;

3.7 15.0 >-

.9 ;

.7 ;

.8 ;

4.3 010 306 1.5 22.8 +-

3.4 13.3'+-

4.1

.7 ;

.9 ;

011 344 0.9 24.5 +-

3.7 14.9 +-

012 142 4.5 25.9 +-

.8 ;

4.3 3.9 16.3 +-

.9 ;

.8 ;

4.4

.9';

4.4 013 158 4.0 25.6 +-

3.8 15.9 +-

.7 ;;

.9 ;

014 180 3.8 24.0 +-

3.6 14.4 +-

4.2

.9 ;;

015 207-4.8 25.4 +-

.8 3.8 15.7 +-

016 225 4.5 26.7 +-

.8 ;

4.4 4.0 17.0 +-

.9 4.5

.8 ;;

.9 ;

017 254 2.7 27.1 +-

4.1 17.3 +-

4.6

.8' 3.9 16.1 +-

.9 ;

018 269 3.0 25.8 +-

.8 ;

.9 ;

4.4 019 295 5.3 26.0 +-

3.9 16.4 +-

.6 ;;

4.4

.7 ;;

020 25 0.5 18.5 +-

2.8 9.2 +-

3.6 021 132 9.7 22.1 +-

.7' 3.3 12.6 +-

.8 ;

4.0 022 210 6.5 MISSINGORDAb8GEDDOSIMETER TRANSIT DOSE = 8.7 +-

.6 ; 2.6 1

1

35 DAVIS BESSE FOR THE PERIOD 831209-840425 TLD DIRECT RADIRTION ENVIRONMENTAL MONITORING I

RZIMUTH (deg. )

NET AVER. EXPOSURE RATE 4 IN GROUP.

CmR/Std.Qtt.) t-Std.Dev.

i 348.75-11.25 (N)

NO DATR+-NO DATR

-0 11.25-33.75 g NNE) 9.2 +- 8.9 1

33.75-56.25 (NE) 10.1 +- B.O 1

56.25-78.75 (ENE)

NO DRTR+-NO DATR 0

78.75-10l.25 (E) 11.B +- B.O 1

101.25-123.75(ESE) 10.9 +- B.O 1

123.75-146.25(SE) 16.3 +- B.O 1

145.25-158.75(55E) 15.9 4-B.O 1

158.75-191.25(5) 13.7 +

.9 2

19L.25-2l3.75(55N) 15.2 4-

.5 2

213.75-236.25(SW) 16.4 +

.9 2

238.25-258.75(WSW) 15.7 +- 2.4 I 2 258.75-281.25(W) 18.2 +

.2 2

28l.25-303.75(WNW) 15.7 +- 1.0 2

I 303.75-326.25(NN) 13.3 +- B.O 1

326,25-348.75(NNN) 14.9 +- 2.0 1

DISTRNCE(mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/5td.Qtc.)

+-5t d. De v.

9-2 13.4 +- 2.5 12 l

2-5 1s.1 +

.9 7

>5 16.4 +- B.O 1

UPNIND CONTROL DRTA 12.6 +- 2.0 1

't I

36 DIABLO CANYON:

2 TLD DIRECT RADIATION ~ ENVIRONMENTAL MONITORING FOR'THE' PERIOD 831208-840504 148 DAYS FIELD TIME 98-DAYS HRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST-EXPOSURE (mR) mR/Std.Qtr.

(.deg.)

(mi.)

+- Rdm; Tot.

+- Rdm 22.1 + ; Tot.

001 125 1.0 32.5 +-

1.0 ;

4.9 1.1 5.3 002 119 4.2 28.1 +-

.8 4.2 18.1 +-

1.0 ;

003 107 6.9 28.2 +-

.8 ;

4.9 4.2 18.2 +-

1.0 ;

004 109 11.

26.7 +-

.8 ;

4.9 1.0 ;;

4.7 4.0 16.8 +-

.9 ;;

005.

113 14.

29.0 +-

4.4 18.9 +-

1. 0 -

5.0 1.0 ;;

006 68 9.6 26.2 +-

.8 3.9 16.3 +-

007 359 11.

23.4 +-

.7 ;

4.6' 3.5 13.7 +-

.9 4.4 008 359 6.6 22.4 +-

.7 ;

3.4 12.9 +-

.9 ;

009 339 4.7 20.6 +-

.6 ;

4 4.3 3.1 11.2 +-

.9 ;

011 332 1.3 21.5 +-

.6 ;

4.1 3.2 12.0 +-

.9 ;

012 37 21.

28.7 +-

.9 ;

4.2 4.3 18.6 +-

1.0 ;

013 37 21, 27.0 +-

.8 ;

4.9 4.1 17.1 +-

1.0 ;

014 37 21.

28.7 +-

.9 *;

4.7 1.0 ;;

4.3 18.7-+-

4.9 018 162 9.3 MISSINGORDAbAGEDDOSIMETER TRANSIT DOSE = 8.4

+-

.7 ; 3.2 1

i t

l 1

4 1

37 DIABLO CANYOH FOR THE PERIOD 831208-840504 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dog.)-

NET RVER. EXPOSURE RATE

$ IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-ll.25 (N) 13.3 +

.5 2

11.25-33.75 (NNE)

NO DRTA+-NO DATR 0

33.75-56.25 (NE)

NO DRTA+-NO DATR 0

56.25-78.75 (ENE) 16.3 +- B.O 1

78.75-10l.25 (E)

NO DRTA+-NO DATR 0

10l.25-123.75(ESE) 18.B +

.5 4

123.75-148.25(SE) 22.1 +- B.O 1

145.25-158.75(55E)

NO DRTR&-NO DRTH 8

358.75-191.25(5)

NO DRTR&-NO DRTR 8

19 L.25-213.75 (SSN)

NO DRTR+-NO DRTR 8

213.75-236.25(SW)

NO DATA &-NO DATR 0

238.25-258.75(W5W)

NO DATAt-NO DATR G

258.75-281.25(W)

NO DRTAt-NO DATR S

281.25-303.75(WNW)

NO DRTAt-NO DATR 0

303.75-326.25(NN)

NO DATRt-NO DATR E

326.25-348.75(NNN) 11.E +

.6 2

OISTANCE(mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/5td.Qtr.)

+-5t d. De v.

B-2 17.1 +- 7.1 2

2-5 14.6 +- 4.0 2

>5 16.1 +- 2.4 6

UPNIND CONTROL ORTA 18.1 +

.9 3

1 s

38 DRESDEN TLD DIRECT RADIATION ENVIRONMENTAL-MONITORING ~

~FOR THE PERIOD 831209-840407-120 : DAYS FIELD TIME 88 DAYS NRC LOCATION:

GROSS NET EXPOSURE RATE CTATION AZIMUTH /DIST~

EXPOSURE (mR) mR/St d. 0t r.

(deg.).(mi.)

+- Rdm; Tot.

+- Rdm 15.8 + ; Tot.

001 70 4.2 19.9 +-

.6- - 3.0

'002 92^

- 3. 9 -

19.3 +-~

.6 ;

.8 3.7-2.9 15.1 +-

.8 ;

.6 ;;

3.6 3.1-16.3 +-

.8 ;

003' 119 3.2

~20.4 +-

3.8

.7 ;

3.5 004 134 1.3 17.9 +-

. 5-2.7 13.8 +-

005-115 1.5 18.6 +-

.6 ;

.8 ;; ~3.6 2.8 14.4 + -

006 180 1.9 20.2 +-

.6 ;

3.0 16.11+--

.8 ; -3.8

.6 ;

007 179 0.5 18.8 +-

2.8 14.6 +-

008 166 0.7 17.6 +-

.5 ;

.8 3.6

.7 ;;

2.6 13.5 +-

3.4 009 205 0.5 MISSINGORDAflAGEDDOSIMETER 010 224 0.7 22.7 +-

.7 3.4 18.6 +-

.5 ;

.9-4.1

. 7 ;;

011 250 0.9 16.7 +-

2.5 12.5 +-

.6 ;

3.1 3.3 012 263 1.6 20.6 +-

16.5 +-

.8 3.8

.5 ;;

2.6 12.9 +-

.7 ;

013 180-4.0 17.1 +-

3.4 014-158 4.8 17.3 +-

.5 2.6 13.1 +-

.7.;

015 137 4.2 20.4 +-

.6 ;

3.4 8 ;;

3.1 16.3 +-

.5 ;;

3.8 016 134 8.4 17.1 +-

2.6 12.9 +-

7 3.4 017 189 7.4 18.8 +-

.6 2.8 14.7 +-

8; 018 203 4.1 17.4 +-

.5 ;

7 ;.3.6 2.6 13.3 +-

.6 ;;

3.4 8 ;;

019 231 3.8 20.9 +-

3.1 16.8 +--

3.8 020 244 6.4 21.2 +-

.6 ;

3.2 17.1 +-

8 3.9 8 ;

3.8 021 258 8.6

-20.9 +-

.6 3.1 16.8 +-

.5 ;;

2.6 13.1'+-

7; 022 269 4.4 17.3 +-

3.4 8 ;;

023 295 3.3 20.6 +-

.61 3.1 16.5 +-

3.8 024 311 3.9 MISSING OR DAllAGED DOSIMETER 025 340 4.7 21.9 +-

.7 3.3 17.9 +-

026 7

4.4 18.6 +-

.6 ;

88 ;

4.e 2.8 14.4 +-

.7 ;;

3.6 8 ;;

027 1

2.0 21.8 +-

3.3 17.7 +-

4.0-028 327 1.7 23.4 +-

.7 ;

3.5 19.3 +-

9 4.2 8 ;;

029 318 1.4 20.6 +-

.6 3.1 16.5 +-

030 301 1.9 18.1 +-

.5 ;

3.8 2.7 14.0 +-

7 3.5 031 30 1.5 21.9 +-

.7 ;

3.3 17.9 +-

8; 032 48 1.9 21.9 +-

.7 ;

4.0 3.3 17.9 +-

8; 033 76 1.4 21.0 +-

.6 ;

4.0 3.2 16.9 +-

8; 034 90 1.4 20.8 +-

.6 ;

3.9 8 ;;

3.1 16.7 +-

.6 ;;

3.8 035 26 4.5 20.6 +-

3.1 16.5 +-

8 3.8 8;

036 42 3.6 18.9 +-

.6 2.8 14.8 +-

037 52/

11.

20.0 +-

.6 ;

3.6 3.0 15.9 +-

8;

.6 ;;

3.7 8 ;;

038 274 23.

20.1 +-

3.0 16.0 +-

3.7 039 274 23.

21.1 +-

.6 ;

3.2 17.0 +-

8 3.9 8 ;;

040 275 24, 20.2 +-

.6 ;

3.0 16.1 +-

3. 7 TRANSIT DOSE = 4.4

+-

.5 ; 2.1

?

l' l

39 DRESDEN FOR THE PERIOD 831209-840407 TLD DIRECT RADIRTION ENVIRONMENTAL MONITORING RZIMUTH (deg.)

NET AYER. EXPOSURE RATE 4 IN GROUP i

l (mR/Std.Qir.) t-Std.Dev.

348.75-!L.25 (N) 16.1 +- 2.3 2

11.25-33.75 (NNE) 17.2 +

.9 2

33.75-56.25 (NE) 16.2 +- 1.6 3

56.25-78.75 (ENE) 16.3 +

.B 2

78.75-!OL.25 (E) 15.9 +- 1.1 2

10l.25-123.75(ESE) 15.4 +- 1.3 2

123.75-146.25(SE) 14.3 +- 1.8 3

145.25-168.75 ( 55E) 13.3 4

.2 2

168.75-191.25(5) 14.5 +- 1.3 4

19t.25-2L3.75(55H) 13.3 4-B.O 1

213.75-236.25(SH) 17.7 +- 1.3 2

236.25-258.75(WSW) 15.5 +- 2.6 3

258.75-281.25(W) 14.B +- 2.4 2

28L.25-303.75(WNW) 15.2 +- 1.0 2

303.75-326.25(NN) 16.5 +- 2.0 1

4 326.25-348.75(NNN) 18.6 +- 1.0 2

1 DISTANCE (mi) FROM THE REACTOR NET RVER.EXPOSUPE RATE

+ IN GROUP (mR/5td.Qte.) + -5t d. De v.

B-2 16.1 +- 2.0 18 2-5 15.2 +- 1.6 14

>5 15.5 +- 1.7 5

UPNIND CONTROL DATA 16.4 +

.6 3

L

40 DUANE ARHOLD TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831212-840412.122 DAYS

' FIELD TIME 93 DAYS

)

NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/St d. 0t r.

(deg.): (mi.)

+- Rdm; Tot.

+- Rdm 14.9 + ; Tot.

001 163 9.7 20.8 +-

.6 3.1

.7 ;;

.8 3.7

.8 ';

002 170 6.2 22.2 +-

3.3 16.3 +-

- 3. 9

.6 3.1 14.9 +-

.8 !

3.7 003 180 3.5 20.8 +-

.7 ;;

004 216 2.9 22.5 +-

3.4 16.5 +-

.8 3.9'

.7 ;;

005 201 2.5 19.3 +-

.6 2.9 13.5 +-

3.5

.6 ;

006 213 1.0 20.9 +-

3.1 15.0 +-

.8 3.7

.6 ;;

.8 ;;

007 248 1.0 21.6 +-

3.2 15.7 +-

3.8 008 279 1.0 20.6 +-

.6 ;

3.1 14.7 +-

4

.8 3.7

.8 ;;

009 298 1.0.

21.7 +-

.6 3.2 15.7 +-

3.8

.7 ;

010 320 1.5 22.4 +-

3.4 16.4 +-

.8 3.9

.7 ;;

3.4 16.5 +-

.8 ;

011 343 1.0 22.5 +-

3.9

.7 3.4 16.5 +-

.8 ;

012 359 1.2 22.5 +-

3.9

.7 ;

.8 ;;

L 013 237 0.5 22.1 +-

3.3 16.1 +-

.6 ;;

3.9 014 259 3.9 21.1 +-

3.2 15.1 +-

.8 3.7

.8 ;;

015 272 5.0 19.7 +-

.6 3.0 13.8 +-

3.6 016 285 5.0 20.1 +-

.- 6 ;

3.0 14.2 +-

.7 ;

.8 3.6 3.3 16.3 +-

.8 ;

017 308 4.5 22.2 +-

.6 ;;

3. 9

.8 ;

018 340 4.5 19.8 +-

3.0 13.9 +-

3.6 019 291 15, 20.8 +-

.6 ;

3.1 14.9 +-

.8 3.7 020 291 15.

22.0 +-

.7 ;

3.3 16.0 +-

.8 ;

4 3.8

.8 ;;

021 291 15.

19.9 +-

.6 3.0 14.0 +-

022 358 6.1 20.2 +-

.6 ;

3.6 3.0 14.3 +-

.8 ;

3.6 023 7

2.9 19.1 +-

.6 ;

4 2.9 13.3 +-

i 024 28 3.0 21.8 +-

.7 ;

.7 3.5

. 8 ;;:

3.3 15.9 +-

.7 ;;

3.8 025 39 3.5 22.4 +-

3.4 16.4 +-

.8 ;

3.9 026 64 3.8 22.6 +-

.7 ;

3.4 16.6 +-

.8 3.9

.8 ;

027 50 1.9 20.0 +-

.6 3.0 14.1 +-

028 72 2.3 22.7 +-

.7 ;

3.6 3.4 16.7 +-

.8 ;

.6 ;;

3.9

.7 ;;

i 029 91 3.0 19.2 +-

2.9 13.4 +-

3.5 030 93 1.8 22.6 +-

.7 3.4 16.6 +-

.8 ;

3.9

.7 ;;

031 113 2.0 23.2 +-

3.5 17.2 +-

.8 4.0

.8 ;

032 141 1.6 19.9 +-

.6 3.0 14.0 +-

033 153 1.5 21.9 +-

.7 ;

3.6 3.3 15.9 +-

.8 ;

.6 ;;

3.8

.8 ;;

i 034 177 1.2 19.5 +-

2.9 13.6 +-

3.6 035 153 4.2 19.7 +-

.6 2.9 13.8 +-

.8 ;

3.6

.6 ;;

036 135 4.1 21.0 +-

3.2 15.1 +-

.8 3.7 1.0 ;;

037 111 4.6 28.3 +-

.8 ;

4.2 22.1 +-

4.6 038 123 5.1 21.2 +-

.6 3.2 15.3 +-

.8 3.8

.6 ;;

.8 ;;

039 132 7.0 20.9 +-

3.1 15.0 +-

3.7 040 139 7.6 22.4 +-

.7 ;

3.4 16.4 +-

.8 ;

3.9 TRANSIT DOSE =

5.4

+-

.5 ; 2.2 i

l l

...-. x n,e.m

41 DUANE ARNOLD FOR THE PERIOD 831212-840412-TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (deg.)

NET AVER. EXPOSURE RATE 4 IN GROUP-(mR/Std.Qtr.) t-Std.Dav.

348.75-il.25 (N) 14.7 +- 1.7 3

11.25-33.75 (NNE) 15.5 +- B.O 1

33.75-56.25 (NE) 15.2 +- 1.6 2

56.25-78.75 (ENE) 16.6 +

.1 2

78.75-101.25 (E) 15.0 +- 2.3 2

101.25-123.75(E5E) 18.2 +- 3.5 3

123.75-146.25(SE) 15.1 +- 1.0 4

14 6.25-168.75 ( 55 E )

14.9 +- 1.1 3

168.75-191.25(5) 14.9 +- 1.3 3

191.25-213.75(55N) 14.2 +- 1.1 2

213.75-236.25(SW) 16.5 +- 8.0 1

236.25-258.75(W5W) 15.9 +

.3 2

258.75-201.25(W) 14.5 t-

.7 3

281.25-303.75(WNW) 15.9 +- 1.1 2

303.75-328.25(NH) 18.3 +

.1 2

326,25-348.75(NNN) 15.2 +- 1.8 2

l' DISTANCE (mt) FRCH THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/5td.Qte.) +-Std.Dev.

B-2 15.8 +- 1.1 14 2-5 15.4 +- 2.1 17

>5 15.3 +

.B 6

UPHIND CONTROL DRTA 15.0 +- 1.0 3

i

42 FARLEY TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR'THE PERIOD 831214-840427 135 DAYS FIELD TIME 99 DAYS NRC LOCATI0t1 GROSS NET EXP000RE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.

(deg.)

(mi )

+- Rdm; Tot.

+- Rdm 13.0 + ; Tot.

001 268 14.

17.9 +-

.5 ;

2.7

.6 ;

2.9 1

002 252 7.8 20.3 +-

.6 ;

3.0 15.2 +-

.7 3.2

.6 ;

003 217 6.1 19.4 +-

.6 2.9 14.3 +-

004 155 5.7 20.5 +-

.6 ;

3.1

.7 ;;

3.1 15.3 +-

.5 ;;

3.2 005 170 5.1 18.2 +-

2.7 13.3 +-

.6 2.9

.6 ;

006 197 4.5 16.6 +-

.5 2.5 11.8 +-

007 191 2.4 21.7 +-

.6 ;

2. 7

.7j; 3.2 16.4 +-

008 200 1.8 18.0 +-

.5 ;

3.3 2.7 13.0 +-

.6 2.9

.5 ;;

2.7 13.3 +-

.6 ;,

2.9 009 220 1.2 18.2 +-

010 254

.9 18.2 +-

.5 2.7 13.2 +-

011 300

.9 19.3 +-

.6 ;

.6 2.9

.6 ;

2.9 14.3 +-

.6 ;;

3.1

.7 ;

012 319 1.1 21.0 +-

3.1 15.8 +-

3.3

.6 ;! 2.9 013 338 1.3 17.7 +-

.5 2.6 12.8 +-

.6

.6 ;

014 256 1.2 18.7 +-

.8 ;;.2.8 13.7 +-

3.0 015 16 1.3 25.5 +-

3.8 19.8 +-

.8 3.8

.6 ;

1 016 264 1.6 18.7 +-

.6 2.8 13.7 +-

.6 ;;

3.0

.7 ;;

017 253 3.5 21.1 +-

3.2 15.8 +-

3.3 018 233 3.2 18.1 +-

.5 ;

2.7 13.2 +-

.6 2.9

.7 ;

t 019 267 4.5 19.9 +-

.6 3.0 14.8 +-

.6 ;;

3.1

.7 ;;

020 295 3.8 21.4 +-

3.2 16.1 +-

3.3 021 315 4.6 17.5 +-

.5 ;

2.6 12.6 +-

.6 2.8

.6 ;;

022 332 4.3 18.3 +-

.5*

2.7 13.3 +-

2.9 023 251 4.8 MISSINGORDAbAGEDDOSIMETER 024 32 5.3 20.1 +-

.6 3.0 15.0 +-

.7 ;

3.2 025 54 6.2 17.3 +-

.5 ;

2.6 12.4 +-

026 64 5.5 19.6 +-

.6 ;

.6 2.8

.6 ;

2.9 14.5 +-

027 88 4.7 19.4 +-

.6 ;

3.1 2.9 14.3 +-

.6 ;

.6 ;;

3.1

. 7 ;;

028 124 5.1 20.5 +-

3.1 15.3 +-

3.2 029 153 4.1 19.1 +-

.6 2.9 14.1 +-

.5 ';

.6 3.0

.6 ;;

030 142 3.6 18.0 +-

2.7 13.1 +-

2.9 031 130 3

MISSINGORDAbAGEDDOSIMETER 032 110 2.8 17.5 +-

.5 ;

2.6 12.6 +-

.6

.6 l; 2.8 j

033 78 2.6 17.4 +-

.5*

2.6 12.5 +-

2.8 034 58 2.2 16.9 +-

.5 l 2.5 12.1 +-

.6 2.8 035 34 2.4 21.5 +-

.6 3.2 16.2 +-

.6 ;;

.7 3.3

.7 ;;

036 19 2.7 20.3 +-

3.0 15.2 +-

3.2 037 284 10 19.3 +-

.6 2.9 14.2 +-

i 038 289 15.

16.5 +-

.5 ;

.6 3.1' t

.6 ;

2.5 11.7 +-

2.7 i

039 293 15.

MISSINGORDAbAGEDDOSINETER TRANSIT DOSE =

3.6

+-

.4 ; 1.7 l

l l

- - ~ ~

43 FARLEY FOR THE PERIOD 831214-840427 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (deg.)

NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-11.25 (N)

NO IIRTA+-N0 DATR 0

11.25-33.75 (NNE) 16.7 +- 2.8 3

33.75-56.25 (NE) 14.3 +- 2.7 2

56.25-78.75 (ENE) 13.0 +- 1.3 3

78.75-10l.25 (E) 14.3 +- 8.0 1

101.25-123.75(ESE) 12.5 +- B.O 1

123,75-146.25(SE) 14.2 +- 1.6 2

145.25-168.75(55E) 14.7 4-

.5 2

168.75-191.25(5)

14. 8 +- 2.2 2

191. 25-2 L 3.75 ( 55N )

12.4 4-.5 2

213.75-236.25(SW) 13.6 4-.7 9

236.25-258.75(W5W) 14.5 +- 1.2 4

258 75-281.25(W) 13.5 +

.5 3

281.25-303.75(WNW) 15.2 +- 1.3 2

303.75-326.25(NN) 14.2 +- 2.2 2

326,25-348.75(NNN) 13.0 +

.4 2

DISTANCE (mi) FROH THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/Std,Qtr.)

+-5t d. De v.

3-2 14.4 +- 2.2 9

2-5 14.0 +- 1.6 18 55 14.3 +- 1.1 9

UPHIND CONTROL DATA

13. 9 +- 1.8 2

44 FERMI TLD DIRECT RADIATI0t1 ENVIR0tlMEllTAL MONITORIllG FOR THE PERIOD 831212-840420 130 DAYS FIELD TIllE 84 DAYS tlRC LOCATION GROSS ttET EXPO!VRE RATE STATICH AZIMUTH /DIST EXPOSURE (mR) mR/St d.Qt r.

(deg.)

(mi.)

+- Rdm; Tot.

+- Rdm Tot.

,6 2.8 N0 flET;DfiTA 001 38 2.1 18.6 +-

.7 ;;

002 22 2.3 22.4 +-

3.4 l10 NET DfiTA 003 350 1.8 22.0 +-

.7 3.3 110 t1ET DfiTA 004 345 1.9 20.4 +-

.6 ;

3.1 N0 ilET DflTA

.7 ;;

005 346 1.4 21.7 +-

3.3 N011ET DfiTA 006 310 1.3 23.1 +-

.7 3.5 N0 ilET DflTA 007 298 1.4 20.7 +-

.6 ;

3.1 N0 flET DflTA 008 277 1.6 21.3 +-

.6 ;

3.2 N0 flET DflTA 009 238 1.0 MISSINGORDAllAGEDDOSIMETER 010 225 1.5 18.8 +-

.6 2.8 fl0 ilET DflTA 011 193 0.8 21.6 +-

.6 ;

3.2 fl0 flET DftTA 012 183 0.9 22.5 +-

.7 ;

3.4 110 NET DfiTA 013 175 0.8 21.2 +-

.6 ;

3.2 NO NET DfiTA 014 260 1.7 MISSINGORDAl1AGEDDOSIMETER 015 245 2.5 21.4 +-

.6 ;

3. 2 N0 NET DitTA 016 236 5.0 23.4 +-

.7 3.5 tl011ET DftTA 017 225 6.8 19.8 +-

.6 ;

3.0 N0 flET DfiTA

.6 ;;

018 250 7.8 19.2 +-

2.9 110 flET Df;TA 019 277 6.0 20.0 +-

.6 3.0 110 ilET DfiTA

.6 ';

020 297 6.0 21.0 +-

3.2 N0 tlET DflTA 021 320 3.8 MISSING OR DAllAGED DOSIMETER 022 340 4.7 21.9 +-

.7' 3.3 110 llET DfiTA 023 358 4.3 MISSINGORDAllAGEDDOSIMETER 024 23 5.0 24.0 +-

.7 ;

3.6 t10 ilET DfiTA 025 25 7.0 19.6 +-

.6 2.9 110 flET DflTA i

026 0

7.0 21.0 +-

.6 ;

3.1 t10 flET DfiTA 027 342 8.0 20.6 +-

.6 ';

3.1 N0 ilET Df TA 028 320 9.5 20.7 +-

.6,I 3.1 110 tiET DflTA 029 290 11.

21.7 +-

.6 3.2 110 NET DfiTA i,

030 270 10.

22.8 +-

.7 ;

3.4 NO NET DflTA

.6 ;;

031 245 10.

20.9 +-

3.1 N011ET DflTA 1

032 220 10.

23.0 +-

.7 ;

3.4 t10 flET DfiTA 033 270 15.

21.0 +-

.6 3.2 fl0 flET DfiTA 034 270 15.

20.7 +-

.6 ;

3.1 N0 flET DflTA 035 290 16, 21.3 +-

.6 ;;

3.2 fl0 tlET DfiTA 036 350 0.8 20.8 +-

.61 3.1 fl0 ilET Df!TA 037 330 0.7 21.4 +-

.6 3.2 110 IIET DfiTA 038 310 0.7 21.5 +-

.6 ;

3.2 tl0 t1ET DfiTA 039 23/

10.

20.6 +-

.6 ;

3.1 N0 flET DfiTA 040 0

9.0 20.7 +-

.6 ;

3.1 11011ET Df;TA

.6 ;

041 348 9.0 19.7 +-

3.0 N0 tiET DfiTA fl0 TRAtlSIT DOSE CALCULATED (TLD C0tlTROLS; MISSING OR OTHERil!!E NO i

i

F 45 FERMI FOR THE PERIOD 831212-840420 TLD DIRECT RADIATION EtWIRONMENTAL MONITORING RIIMUTH (deg.)

AYER. EXPOSURE RATE

$ IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348,75-11.25 (N) 14.5 +

.4 4

11.25-33.75 (NNE) 15.8 +- 1.4 4

33.75-56.25 (NE) 12.E +- 8.0 1

56.25-78.75 (EFC)

NO DATA +-NO DATR G

78.75-101.25 ( E.1 NO DRTA+-NO DATR S

101.25-123.75(ESE)

NO DFTA+-NO DATR G

123.75-146.25(SE)

NO DATA +-NO DATR G

145.25-169.75(55E)

NO DRTA+-NO DATR 8

168.75-191.25(5) 15.1 4

.E 2

19L.25-2L3.75(55N1 15.8 4-8.0 1

213.75-236.25(SW) 14.7 4-1.6 4

236,25-258.75(W5u) 14.2 +

.5 3

259.75-201.J5(W) 14.5 t-1.0 3

2GL.25-303.75(WNW) 14.5 +

.3 3

303.75-326.25(NN) 15.1 +

.5 3

326.25-340.75(NNN) 14.5 +

.5 6

DISTRNCE(mt) FROM THE PEACTOR RVER. EXPOSURE PATE

+ 1N GROUP

( mR/ Std. Q t r'. ) +-Std.Dev.

B-2 14.7 +

.7 13 2-5 15.2 +- 1.3 6

>5 14.3 +

.5 15 UPHINO CONTROL ORTA 14.5 +

.2 3

46 FITZPATRICK/ HINE MI.

TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831215-840423 130 DAYS FIELD TIME 79 DAYS HRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deg.)

(mi.)

+- Rdm

+- Rdm 20.1 +; Tot.

14.4 + ; Tot.

001 230 6.9

.6 3.0 002 184 14 19.3 +-

.6 ;

.9 4.3 2.9 13.4 +-

.9 ;

.6 ;;

4.1

.9 ;;

003 122 8.4 19.3 +-

2.9 13.5 +-

4.1 004 76 10.

19.4 +-

.6

2. 9 13.6'+-

.6 ;;

.9 4.2

.9 ; ~4.2 005 91 6.8 19.8 +-

3.0 14.0 +-

006 112 4.3 18.8 +-

.6 2.8 12.9 +-

.9 l 4.2 007 138 4.3 20.1 +-

.6 ;

.8 4.1 3.0 14.4 +-

2.9 13.2 +-

.9 ';

008 152 3.6 19.1 +-

.6 I 4.1

.6 ;l 2.8 009 183 3.9 19.4 +-

.6 2.9 13.6 +-

.9 I 4.2 010 205 4.5 18.9 +-

.9 ;! 4.1 13.0 +-

.9 011 220 4.4 19.7 +-

.6 2.9 13.9 +-

.6 ;

4.2 012 230 6.1 19.7 +-

2.9 13.9 +-

.9 4.2 013 245 1.8 20.3 +-

.6 ;

3.0 14.6 +-

.9 ;

014 223 1.8 19.6 +-

.6 ;

4.3 2.9 13.8 +-

.9 ;

i 015 204 2

19.6 +-

.6 ;

4.2

.9 ;

2.9 13.8 +-

.6 ;;

4.2

.9 ;

016 181 1.8 20.0 +-

3.0 14.3 +-

4.2

.9 ;;

017 157 1.9 20.7 +-

.6 3.1 15.1 +-

018 137 1.6 19.3 +-

.6 ;

4.3 2.9 13.4 +-

.9

  • 4.1 019 115 1.2 19.4 +-

.6 *;

2.9 13.6 +-

.9 I 4.1 020 92 1.1 20.4 +-

.6 I 3.1 14.7 +-

.9 !

4.3 021 229 19.

18.5 +-

.6 !

2.8 12.5 +-

.8 4.0 022 229 19.

18.3 +-

.5 2.7 12.3 +-

.8 ;

023 229 19, 18.4 +-

.6 ;

4.0 2.8 12.5 +-

.8 I 4.0

.6 l 2.7 024 196 8

18.1 +-

.5 12.1 +-

.8 !

4.0 025 168 7.2 18.7 +-

2.8 12.8 +-

.6 ;;

.8 4.1

.9 ;;

026 152

.6 20.7 +-

3.1 15.0 +-

4.3 TRANSIT DOSE =

7.5

+-

.5 ; 2.2 I

1 I

i l

J

47 FITZPATRICK.' HINE Hl.

FOR-THE PERIOD 831215-840423 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dog.)

NET AVER. EXPOSURE RATE 4 IN GROUP

(=R/Stil.Qt r. ) t-Std.Dav.

348.75-11.25 (N)

NO DRTA+-N0 DATR 0

11.25-33.75 (NNE)

NO DATR+-NO DATR 0

33.75-56.25 (NC)

NO DATA +-NO DATR 0

56.25-78.75 (ENE) 13.5 +- B.O 1

78.75-10l.25 (E) 14.4 +

.5 2

l 101.25-123.75(ESE) 13.3 +

.3 3

123.75-146.25(SE) 13.5 +

.6 2

145.25-158.75 ( 55 E )

14.8 +- 1.2 4

168.75-19. 25(5) 13.5 4-.5 3

191.25-2L3.75(55H) 13.5 4-.5 3

213.75-236.25(SW) 14.0 +

.3 4

236.25-258.75(WSW) 14.8 +- 9.0 1

{

258.75-281.25(W)

NO DRTAt-NO DATR 9

2GL.25-303.75(WNW)

NO DATRt-NO DATA 0

{

303.75-326.25(NN)

NO DATAr-NO DATR G

326.25-348.75(NNN)

NO DRTR+-NO DATR 0

i i

i i

i i

i DISTANCC ( m t ) FROH THE REACTOP NET RVER. EXPOSURE PATE 4 IN GROUP i

(mR/5td,0tr.) + -St d. De v.

i B-2 14.2 +

.5 9

2-5 13.5 +

.5 6

55 13.5 +

.7 8

I UPHIND CONTROL DRTA 12.4 +

.1 3

i i

l

______..._.m._.,..

. ~

48 FT.CALHOUM TLD DIRECT RADIATION ENVIR0tittENTAL MONITORIllG FOR THE PERIOD 831208-840417 131 DAYS FIELD TIME 97 DAYS tlRC LOCATION GROSS tlET EXPO!URE RATE STfiTION AZINUTH/DIST EXPOSURE (mR) mR/Std.0tr.

(deo.)

(mi.)

+- Rda; Tot.

+- Rdm N0 ilET; Tot.

001 358 2.0 22.1 +-

.7 ;

3.3 DflTA 002 351 4.6 22.4 +-

.7 ;

3.4 N0 ilET DfiTA 003 30 2.5 22.5 +-

.7 3.4 N0 flET DflTA l

.6 ;;

004 27 4.6 20.7 +-

3.1 N0 ilET DflTA 005 53 1.9 22.0 +-

.7 3.3 N0 NET DflTA 006 37 3.9 22.3 +-

.7 ;

3.3 N0 flET DflTA 007 76 2.3 23.8 +-

.7 ;

3.6 N0 llET DflTA 008 59 5.2 23.7 +-

.7 ;;

3.5 NO NET Df TA 1

009 100 2.3 21.9 3-

.7 3.3 N0 ilET DfiTA

.6 ;;

010 88 5.6 21.2 +-

3.2 fl0 ilET DftTA 011 122 2.3 23.0 +-

.7 3.4 N0 ilET DfiTA 012 105

5. 7 21.8 +-

.7 ;

3.3

!10 ilET DfiTA 013 145 1.9 23.6 +-

.7 ;

3.5 fl0 NET DfiTA

.7 ;;

014 128 5.5 22.9 +-

3.4 fl0 NET DflTA 015 157 1.9 24.3 +-

.7 3.6 il0 flET DflTA

.7 ;;

016 150 4.9 23.0 +-

3.4 t10 IIET Df:TA 017 173 0.5 23.1 +-

.7 3.5 t10 flET DftTA

.7 ;

018 173 5.3 23.9 +-

3.6 t10 NET DfiTA i

019 212 2.5 MISSIllG OR DAllAGED DOSINETER 020 204 5.3 23.0 +-

.7 3.4 NO NET DfiTA 021 233 2.0 23.9 +-

.7 ;

3.6 fl0 NET DflTA 022 224 4.6 23.4 +-

.7 ;

3.5 N0 flET DfiTA

.7 ;;

023

?39 0.6 22.7 +-

3.4 110 liET DfiTA 024 243 6.9 22.4 +-

.7 ;

3.4 N0 tlET DflTA 025 269 3.3 24.2 +-

. 7 ;~

3.6 110 flET DfiTA 026 262 5.9 24.1 +-

.7*

3.6 fl0 NET Df!TA 027 288 2.8 NISSIrlGORDAllAGEDD05IMETER 028 292 5.0 22.4 +-

.7 3.4 t10 NET Df!TA

.7 ;;

029 311 2.4 23.3 +-

3.5 N0 NET DfiTA 030 310 5.5 24.5 +-

.7 :

3.7 NO NET Df:TA 031 340 2.3 21.0 +-

.6 3.2 tl0 NET DfiTA

.6 ;;

032 338 5.3 21.7 +-

3. 2 tl0 flET DfiTA 033 182 0.5 24.0 +-

.7 i 3.6 t10 flET DflTA r

035 127 2.2 21.4 +-

.6 ;

3.2 fl0 NET Df!TA 039 150 5.0 22.6 +-

.7 3.4 tl0 NET DfiTA I

.7 ;;

040 73 9.5 25.0 +-

3. 7 N0 flET Df:TA i

043 29 8.0 24.0 +-

.7 t 3.6 NO NET DfiTA 044 65 3.5 20.2 +-

.6 3.0 t10 NET DfiTA l

045 192 4.2 23.2 +-

.7 ;

3.5 t10 NET Df!TA 047 298 4.5 23.5 +-

.7 ;

3.5 N0 NET DflTA l

049 13 14.

21.2 +-

.6 !

3.2 fl0 flET DfiTA 049 207 19, 23.8 +-

.7 3.6 N0 NET Df;TA NO TFANSIT LOSE CALCULATED (TLD CollTROLS; HISSING OR OTHERWISE il0T C r

l I

t

49 FT.CALHOUN i

FOR THE PERIOD 831208-840417 TLD DIRECT RADIATION ENVIRONMENTAL N0HITORING RZIMUTH (dog.)

AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-il.25 (N) 15.3 +

.1 2

11.25-33.75 (hNE) 15.4 +- 1.1 3

33.75-56.25 (NE) 15.2 +

.2 2

56.25-78.75 (ENE) 15.8 +- 1.4 4

78.75-101.25 (E) 14.5 +

.3 2

191.25-123.75(ESE) 15.4 +

.B 2

123.75-148.25(SE) 15.5 +

.I 3

146.25-168.75(55E) 16.8 +

.E 3

168.75-151.23(5) 16.2 +

.3 4

151.25-2L3.75(55H) 15.8 4-8.0 1

213.75-236.25(SW) 16.2 +

.3 2

236.25-258.75(WSW) 15.5 +

.1 2

258.75-281.25(H) 16.1 +

.9 2

28 L.25-303.75 ( WN',0 15.B +

.5 2

303.75-328,25(NH) 16.4 +

.8 2

326.25-348.75(NNN) 14.7 +

.3 2

i i

I DISTANCE (mt) FROM THE REACTOR RVER. EXPOSURE RATE

+ IN GROUP (rnR/Etd Qtt.) +-st d. De v.

8-2 15.5 +

.I 8

2-5 15.4 +

.I 15 1

>5 15.B +

.I 12 UPHIND CONTROL ORTA 15.4 +- 1.3 2

50 FT. ST. YRAIN TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831208-840411 125 DAYS FIELD TIME 97 DAYS NRC LOCATION GROSS HET EXPO!URE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.

(deo.)

(mi.)

+- Rdm; Tot.

+- Rdm 23.6 + ; Tot.

001 8

0.8 32.4 +-

1.0 ;

4.9 1.1 5.2 1.0 4.9 23.6 +-

1.1 ;

002 2

3.3 32.4 +-

1.0 ;;

5.2 1.1 ;;

003 29 2.6 34.4 +-

5.2 25.4 +-

5.4 004 17 5.4 34.0 +-

1.0 ;

5.1 25.1 +-

1.1 5.4 1.0 ;;

005 54 2.1 29.1 +-

.9 ;

4.4 20.5 +-

4.8 006 48 4.8 37.0 +-

1.1 5.5 27.8 +-

1.2 ;

5.7 1.1 ;

007 76 2.6 35.1 +-

5.3 26.1 +-

1.1 5.5 008 58 4.2 35.0 +-

1.1 ;

5.3 26.0 +-

1.1 ;

5.5 1.0 ;;

1.1 ;

009 100 1.5 33.9 +-

5.1 25.0 +-

5.4 010 87 4.5 32.i +-

1.0 ;

4.9 23.9 +-

1.1 ;

5.2 011 118 1.6 36.2 +-

1.1 ;

5.4 27.1 +-

1.2 ;

5.6 1.2 ;

012 104 3.0 36.2 +-

1.1 ;

5.4 27.1 +--

5.6 013 143 1.6 35.5 +-

1.1 ;

5.3 26.5 +-

1.1 ;

5.6 014 128 4.5 36.1 +-

1.1 ;

5.4 27.0 +-

1.2 5.6 015 168 2.3 34.3 +-

1.0 5.1 25.3 +-

1.1 ;

5.4 016 148 4.6 39.9 +-

1.2 ;

1.3 ;;

6.0 30.5 +-

1.1 ;

6.1 017 182 0.8 37.6 +-

5.6 28.4 +-

1.2 ;

5.8 1.0 ;;

018 175 4.8 35.0 +-

5.2 25.9 +-

1.1 ;

5.5 019 210 0.9 36.1 +-

1.1 ;

5.4 27.0 +-

1.2 5.6 020 200 2.9 36.0 +-

1.1 ;

5.4 26.9 +-

1.2 ;

5.6 021 234 1.3 37.2 +-

1.1 ;

5.6 28.0 +-

1.2 ;

5.8 1.0 5.0 24.2 +-

1.1 ;

022 216 3.3 33.1 +-

1.0 ;;

5.3 1.1 ;;

023 254 2.5 32.4 +-

4.9 23.5 +-

5.2 024 244 3.8 34.9 +-

10; 5.2 25.9 +-

1.1 5.5 1.1 ;;

025 278 1.5 33.4 +-

1.0 ;

5.0 24.5 +-

5.3 026 263 5.4 34.1 +-

1.0 ;

5.1 25.1 +-

1.1 ;

5.4 027 297 1.7 32.7 +-

1.0 4.9 23.8 +-

1.1 ;

5.2 028 284 5.6 33.8 +-

1.0 ;

5.1 24.8 +-

1.1 ;

5.3 029 317 0.9 30.8 +-

.9 ;

4.6 22.1 +-

1.0 5.0

.9 ;

4.6 22.0 +-

1.0 ;

030 305 4.2 30.7 +-

1.0 ;;

5.0 4.9 23.9 +-

1.1 ;

031 338 1.4 32.7 +-

5.2 1.0 ;;

032 330 5.0 30.1 +-

.9 4.5 21.4 +-

4.9 033 267 6.5 MISSING OR DAMAGED DOSIMETER 034 130 3.7 34.7 +-

1.0 ;

5.2 25.7 +-

1.1 ;

5.5 035 270 0.1 35.1 +-

1.1 5.3 26.1 +-

1.1 ;

5.5 1.1 ;;

038 345 6.7 37.1 +-

5.6 27.9 +-

1.2 ;

5.8 039 10 6.0 36.2 +-

1.1 ;

5.4 27.1 +-

1.2 5.6 1.1 ;;

040 63 6.0 35.1 +-

1.1 ;

5.3 26.1 +-

5.5 041 165 12.

37.9 +-

1.1 5.7 28.7 +-

1.2 ;

5.9 042 248 13, 45.9 +-

1.4 ;;

6.9 36.1 +-

1.4 6.9 1.2 ;;

045 198 11, 37.9 +-

1.1 ;

5.7 28.7 +-

5.9 046 39 16.

34.8 +-

1.0 l 5.2 25.8 +-

1.1 ;

5.5 047 357 17, 32.8 +-

1.0 ;

4.9 24.0 +-

1.1 ;

5.2 048 171 18, 36.8 +-

1.1 ;

5.5 27.7 +-

1.2 ;

5.7 049 360 0.5 36.5 +-

1.1 ;

5.5 27.3 +-

1.2 ;

5.7 l

TRANSIT DOSE =

7.0

+-

.6 ; 2.7 I

l I

L

51 FTo ST. VRAIN FOR THE PERIOD 831208-840411 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMU1H (dsg.)

NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dav.

348.75-1L.25 (N) 24.7 +- 2.0 3

~

11.25-33.75 (NNE) 25.2 +

.2 2

33.75-56.25 (NE) 24.7 +- 3.8 3

56.25-78.75 (ENE) 26.1 +

.1 3

78.75-101.25 (E) 24.4 +

.8 2

101.25-123.75(ESE) 27.1 +

.0 2

123.75-146.25(SE) 26.4 +

.7 3

14 6.25-168. 75 ( 55 E )

28.2 +- 2.6 3

168.75-191.25(5) 27.2 +- 1.7 2

19L.25-213.75(55N) 27.5 +- 1.0 3

213.75-236.25 ('j H )

26.1 +- 2.7 2

236.25-250.75(61581) 28.5 +- B.7 3

250.75-281.25(61) 25.2 +

.8 3

28 l.25-303. 75 ( LJNil) 24.3 +

.7 2

303.75-326.25(NN) 22.0 +

.1 2

326.25-348.75(NNN) 24.4 +- 3.3 3

OISTANCE(mi) FROM THE REACTOP NET RVER. EXPOSURE RATE

+ I N GR OUP

( n,R/5td. 0 t r. )

+-5t d. De v.

0-2 25.5 +- 2.0 12 2-5 25.2 +- 2.4 19

>5 27.5 +- 3.4 10 UPHIND CONTROL DRTA 26.3 +- 2.1 3

E M

y

~-

g re g,

x

~

i 52

  • GINNA s.

.,.RD DIRECT RADI ATION. ENVIRONMENTAL MONITORING.

" :' FOR THE PERIOD 831215-840423 130 DAYS FIELDaTIME 80' DAYS x

NRC-LOCATION GROSS NET EXPOSURE RATE-STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.

(deg.)

(mi.)

+- Rd.Ti; Tot.

14.3 + ; Tot.

+- Rdm N'

001 95 1.' 7 19.4 +-

.6 ;

2.9

.8 ;

4.0 i

002" 108 1.1 17.8-+-

.5.;

2.7 12.5 +-

.8 ;

3.8 003 142 1.7 18.0 +-

. 5 --

2.7 12.7 +-

.8 3.8

.6';;

.8 ;;

004-154 1.5 18.6 +-

3.9

-2. 8 13.4 +-

, 005 174 1.4 19.1 +-

.6 2.9-14.0 +-

.8 4.0 i

.5 ;

.8 ;

006' 212 1.6 18.3 +-

2.7 13.1 +-

3.9

.5 ;

.8 ;

007 244

.9

.18.1 +-

2.7 12.8 +-

3. 9.

.6 ;

.8 ;

008 230

.6 19.7 +-

3.0 14.6 +-

4.1

.6 ;;

.8 ;

010 266 1.5 18.5 +-

2.8 13.3 +-

3.9

.8 ;

011 264 4.6J 18.5 +-

.6 ;

2.8 13,2 +-

3.9

.8 ;

012 245 3.8 18.4 +-

.6 2.8 13.1 +-

3.9

.6 ;

.8 ;

013 235 4.2 19.2 +-

.6 ;

.8 ;

4.0 2.9 14.0 +-

014 '

200 3.8 18.7 +-

2.8 13.5 +-

3.9

.6 ;;

.8 ;

015 178 3.4 19.8 +-

3.0 14.7 +-

4.1

.8 ;

016 168 3.7 17.9 +-

.5 2.7 12.6 + -

3.8

.5 ;

.8 ;

817' 134' 3.8 17.8 +-

2.7 12.5 +-

3.8

.6 ;

.8 ;

618 115-4.3 18.6 +-

2.8 13.4 +-

3.9

.6 ;

.8 ;;

419 88 4

18.5 +-

2.8 13.2 +-

. 3. 9 020 90 6.2 MISSINGORDAl1AGEDDOSIMETER 021 123 7.6 17.8 +-

.5 ;

2.7 12.5 +-

.8 ;

3.8 022 105 12.

18.3.+-

.5 ;

2.7 13.1 +-

.8 ;

3.9 023 151 11.

18.2 +-

.5 ;

2.7 12.9 +--

.8 3.9

.9;

-024 212 13.

21.9 +-

.7 ;

3.3 17.1 +-

4.4

.8 ;;

025 223 13.

18.8 +-

.6-2.8 13.6 +-

-3.9 026 242 16.

MISSINGORDAlIAGEDDOSIMETER 5.2 027 254 14.

27.5'+-

.8 ;

4.1 23.4 +-

1.1 ;

028 234 6.9 18.0.+-

.5 2.7 12.7 +-

.8 3.8

.6 ;;

.8 ;;

029 185

.3 19.7 +-

3.0 14.6 '-

4.1 030 264 14.

18.1 +-

.5 ;

2.7 12.8 +--

.8 ;

3.9 TRANSIT DOSE =

6'. 7

+-

.5 ; 2.1

53 GINNA FOR THE PERIOD 831215-840423 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dag.)

NET AVER. EXPOSURE RATE

  • IN GROUP (mR/Std.Otr.) t-Std.Dev.

348.75-il.25 (N)

NO DATR+-NO DATR 0

11.25-33.75 (NNE)

NO DRTA+-NO DATR 0

33.75-56.25 (NE)

NO DRTA+-NO DATR 0

56.25-78.75 (ENE)

NO DRTA+-NO DATR 0

78.75-10l.25 (E) 13.7 +

.7 2

101.25-123.75(ESE) 12.8 +

.5 4

123.75-146.25(SE) 12.8 +

.2 2

14 6.25-158. 7 5 ( 55 E )

13.0 4-

.1 3

158.75-191.25(5) 14.4 +

.i 3

19L,25-2L3.75(SSN) 14.5 +- 2.2 3

213.75-236.25(SW) 13.7 +

.8 4

236.25-258. 75 (llSW )

13.0 +

.2 2

250.75-281.25(W) 13.3 +

.B 2

281.25-303.75(WNW)

NO DRTAt-NO DATR 0

303.75-326.25(NH)

NO DATAt-NO DATR 0

326.25-348.75(NNN)

NO DATA +-NO DATR 0

OISTANCE(mi) FRON THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (nR/5td.0tr.) +-5td.Dev.

0-2 13.5 +

.B 10 2-5 13.4 +

.7 8

>5 13.6 +- 1.7 6

UPNIND CONTROL ORTA 18.1 +- 7.5 2

54 GRAND GULF TLD DIRECT RADIATION ENVIRONMENTAL-MONITORING

.FOR-THE PERIOD 831214-840417 125 DAYS FIELD. TIME 97 DAYS.

. NRC LOCATION GROSS-NET EXPOSURE RATE

. STATION AZIMUTH /DIST

~ EXPOSURE (mR) mR/Std.Qtr.

(dea.)~ (mi.)

20.0 +; Tot.

14.7 + ; Tot.

+- Rda

+- Rdm 002 35I-1.6

.6.;

3.0

.7 3.4 i

.8 ;

003-20 1.5 22.7 +-

.7 3.4 17.2 +-

3.7-004 51 2.3 20.6'+-

.6 ;

.7 ;

3.1 15.3 +-

3.5-

.7 ;

.8 ;

005 68 2.7 22.2 +-

3.7 3.3-

.16.8 +-

.6 ;;

.7 ;;

006-47 4.1 20.5 +-

3.1 15.2 +-

3.5 i

007 68 4.9 23.4 +-

.7 3.5.

17.9 +-

.8 3.8 008 91 3.2 24.5 +-

.7 ;

. 8 ;;

3.7 18.9 +-

4.0

.6 ;' 3.2

- 009 81 1.0 21.1 +-

15.8'+-

.8 ;

3.6

.7 ;

010 109 0.6 24.2 +-

3.6 18.6 +--

.8 3.9

.7 ;

.8 ;

011 139 0.8 24.2 +-

3.6 18.6 +-

3.9

. 7 ;;-

.8 ;-

012 185 1.6 22.7 +-

3.4 17.2 +-

3.7

.8 ;;

013 207 1.9 23.2 +-

.7 ;

3.5 17.7 +-

3.8 014 247 1.5 MISSING OR DAMAGED DOSIMETER 015 130 4.0-

??.9 +-

.7 3.4 17.4 +-

.8 3.8

.7 ;;

.8 ;

016 122 4.8 22.9 +-

3.4 17.'4 +--

3.8

.8 ;

017 135

.5.3 21.4 +-

.6 3.2 16.0 +--

3. 6 '

.6 ;

.7 ;;

3.4 018 147 4.3 19.8 +-

3.0 14.6 +-

019 224-6.8 23.6 +-

.7 ;

3.5 18.0 +-

.8 ;

3.8

.6 ;

020 172 3.6 21.3 +-

3.2 15.9 +-

.8 3.6

.6 ;;

.8 ;

021 291 12.

21.1 +-

3.2 15.8 +-

3.6

.8 ';

022 332 8.0 23.5 +-

.7 '

3.5 18.0 +-

3.8 023 310 7.9 MISSINGORDAllAGEDDOSIMETER i

024 281 7.0 20.4 +-

.6 ;

3.1 15.1 +-

.7 ;

3.5 025 291 4.8 22.1 +-

.7 3.3 16.7 +-

.8' 3.7

.6 ;;

026 248 9.5 20.2 +-

3.0 14.9 +-

.7 3.5 027 239 12.

19.5 +-

.6 ;

2.9 14.2 +-

.7 ;

3.4 029 090 0.9 21.4 +-

.6 ;

3.2 16.1 +-

.8' 3.6 030 67 51 19.1 +-

.6 ;

2.9 13.9 +-

.7 3.3 031 67 51 18.5 +-

.6 2.8 13.3 +-

.7 !

3.3 032 67 51 18.3 +-

.5 ;

I 2.7 13.1 +-

.7 3.2

.7 ;;

3.5 17.9 +-

. 8 ' '! 3.8 033 206 4.8 23.4 +-

TRANSIT DOSE = 4.1

+-

.5 ; 2.2 e

55 GRAND GULF-FOR THE PERIOD 831214-840417

-TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dag.)

NET RVER. EXPOSURE RATE

.

  • IN GROUP (mR/Std.Qtr.) t-Std,Dev.

348.75-11.25 (N) 14.7 +- B.O 1

11.25-33.75 (NNE) 17.2 +- B.O 1

33.75-56.25 (NE) 15.2 +- [1 2

56.25-78.75 (ENE) 17.3 +

.8 2

78.75-101.25 (E) 16.9 +- 1.7 3

10l.25-123.75(ESE) 18.0 +

.9 2

123.75-146.25(SE) 17.3 +- 1.3 3

145.25-158.75(55E) 14.5 +- B.O 1

158.75-191.25(5) 15.5 +

.9 2

19L.25-2l3.75(55H) 17.B +

.1 2

213.75-236.25(SW) 10.0 +- B.O 1

236.25-258.75(WSW) 14.6 +

.5 2

258.75-281.25(W) 15.1 +- G.0 1

281.25-303.75(WNW) 18.2 +

.7 2

303.75-328.25(NN)

NO BRTAt-NO DATR G

326.25-348.75(NNN) 18.0 +- B.O 1

l l

t DISTANCE (mi) F~ ROM THE REACTOR NET RVER. EXPOSURE RATE 4 IN GROUP j

(mR/5td,Qte.) +-5t d. De v.

B-2 17.B +- 1.4 8

2-5 16.7 +- 1.4 11

>5 16.0 +- 1.5 7

UPNIND CONTROL DRTA 13.4 *

.4 3

.56 HADDAM HECK TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831215-840413 120 DAYS FIELD TIME-92-DAYS NRC

' LOCATION.

GROSS.

NET EXPOSURE ~ RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std. 0t r.

(deg.)

(mi.)

+- Rdm; Tot.

N0 flET; Tot.-

+--Rdm 1

002-17 2.6 24.3 +-

.7 3.6 DfiTA 003.

45 1.9 19.6 +-

.6 ;

2.9 N0 ilET Df!TA 004 67-2.3 20.9 +-

.6 ;

005 93 1.6 21.0 +-

-.6-;;. 3.1 N0 flET Df!TA

- 3. 2 -

N0 t1ET DflTA -

006 115 2.3 19.8'+ -

.6 ;

3.0 NO-flET DATA 007 143 1.9 22.2 +-

.7 ;

3.3 tl0 flET DflTA 008 165

.9 20.3 +-

.6-tl0 flET Df!TA

.7 ;

3.0 009 174 1.3 23.1 +-

3.' 5

- NO NET DfiTA

.6 ;

010 195

. 7-20.8 +-

3.1 NO NET DflTA

.7 ;

_.8 21.8 +-

012 241 3.3 NO NET DflTA 013 263

.8 19.8 +-

-.6 3.0 t10 NET DfiTA

.7 ;

014 290 1.9 22.2 +-

3.3 N0 NET Df!TA

.6 ;

015 311 1.5 18.6 +-

2.8 N0 ilET DflTA

.6 ;

016 341 1.3 20.7 +-

3.1 -

N0 flET' DflTA 017 360 2.3 MISSINGORDAl1AGEDDOSINETER 018 222 2.5 21.2 +-

.6-3.2 N0 NET DATA

.6 ;;

019

?69 3

20.8 +-

3.1 tl0 NET DflTA 020 66 3.2 21.0 +-

.6 ;

3.2 N0 llET DflTA 021 91 2.8 22.4 +-

.7 3.4 NO NET DflTA

.6 ;;

022 112 3.2 20.4 +-

3.1 N0 flET DflTA 023 137 2.9 20.0 +-

.6 ;

3.0 t10 flET DflTA 024 155 7.1 20.3 +-

.6 ;

3.0 t10 IlET DflTA 025 175 5.7 21.8 +-

.7 3.3 N0 llET DATA

.6 ;;

026 196 2.5 19.5 +-

2.9 N0 flET DflTA 027 225 1.1 23.0 +-

.7 ;

3.4 Il0 llET DflTA

)

028 250 3.5 20.2 +-

.6 3.0 N0 flET DflTA 1.0 ;

029 340 20 33.7 +-

5.1 NO NET DflTA

.6 ;

-030 286 3.2 19.6 +-

2.9 l10 flET DflTA

.6 ;

i 031 322 2.7 21.0 +-

3.2 t10 flET DflTA

.7 ;

i 032 327 2.9 24.1 +-

3.6 t10 NET DflTA

.6 ;

i 033 359 6.4 19.4 +-

2.9 N0 flET DflTA

.6 ;;

t 035 54 10.

21.0 +-

3.2 t10 llET DfiTA i

036 72 8.8 23.5 +-

.7 ;

3.5 110 NET DfiTA 037 149 6.8 19.1 +-

.6 ;

2.9 110 ilET DflTA 2

038 158 5.9 20.4 +-

.6 ;

3.1 t10 NET DfiTA 039 267 8.8 20.8 +-

.6 ;

3.1 fl0 NET DflTA 4

040 303 9.1 22.3 +-

.7 3.3 fl0 NET DfiTA

.6 ;;

041 313 9.6 19.7 +-

3.0 fl0 NET DflTA 042 320 13.

22.9 +-

.7 ;

3.4 t10 NET DfiTA i

043 324 18 20.2 +-

.6, 3.0 l10 llET DflTA i

044 328 15 20.8 +-

.6 ;

3.1 N0 flET DfiTA 045 343 18 22.7 +-

.7 ;

3.4 t10 ilET DfiTA 046 144 5

20.9 +-

.6-3.1 fl0 ilET DflTA 047 330 20 MISSINGORDAE1AGEDDOSIMETER 049 340 20 22.1 +-

.7 3.3 110 flET DflTA l

Il0 TRANSIT DOSE CALCULATED (TLD CONTROLS;MISSIllG OR OTHERWISE h0T COMP 1

57 HADDAM HECK FOR THE PERIOD 831215-840413 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dog.)

AVER. EXPOSURE RATE

  • IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-11.25 (N) 14.5 +- 0.0 1

11.25-33.75 (NNE) 18.2 +- 0.0 1

33,75-56.25 (NE) 15.2 +

.7 2

56.25-78.75 (ENE) 16.3 +- 1.1 3

78.75-101.25 (E) 16.3 +

.7 2

101.25-123.75(ESE) 15.1 +

.3 2

123,75-14 6. 25 ( S E )

15.8 +

.8 3

145.25-158.75(55E) 15.0 +

.5 4

158.75-191.25(5) 15.8 4-

.7 2

19 t.25-213.75 (55H) 15.1 4-

.7 2

213.75-236.25(SN) 16.6 +

.9 2

236.25-258. 75 ( L1564 )

15.7 +

.8 2

258.75-201.29(H) 15.4 +

.4 3

281.25-303. 75 ( 64NH )

16.0 +- 1.1 3

303.75-326.25(NH) 15.4 +- 1.2 5

326.25-348.75(NNH) 18.3 +- 4.1 5

DISTANCE (mi) FRON THE REACTOR RVER. EXPOSURE RATE

+ IN GROUP (mR/5td,0tr.)

+-5t d. De v.

Q-2 15.8 +- 1.0 12 2-5 15.8 +- 1.1 15

>5 16.4 +- 2.6 15 UPHIND CONTROL DATA 16.8 +- 0.0 1

HATCH ~

.58

~TLD DIRECT. RADIATION ENVIRONMENTAL MONITORING

-FOR THE PERIOD 831214-840413 121 DAYS FIELD TIME:

89 DAYS

'HRC' LOCATION-GROSS-HET EXPOSURE RATE:.

STATION AZIMUTH /DIST-EXPOSURE (mR)-

mR/Std.Qtr.

(deg.)

(mi.).

+- Rdm; Tot.

15.6 + ;Tcit.

+- Rdm

~.7 3.5 001 342

- 23 19.7 +-

.6 ;

3.0-

.7 ;' 3.4 902-359 7.7 18.9 +-c

.6 ;

2.8 14.8 +-

.7 ; '3.4 i

003 354 4.5-

'18.3,+-

.5 ;

2.7-

.14.1 +-

.7 ;

3.3

.5 13.8 +-'

.5 ; '2.7

.7 ';

004' 336 2.9 17.9 +-

13.9 +-

3.3

.6 ;

-2.7-

.7 ;

-005'

'309 4.6 18.1 +-

2.8-

-14.8 +--

3.4 006 297-5.6 18.9 +-

.5 ;

.7 ;

3. 3.

13.7 +-

. 5';;

2.7 007 24-2.8 17.8 +-

.7 ;-

3.4

- 2. 7 -

14.1 +-

008 49; 2.0 18.3 +-

.7 ;

j 3.3 009 49/

10.-

'18.0 +-

.5 ;

2.7-13.8 +-

010 28 4.8 19.0'+-

.6 ;

2.8 14.8 +-

.7, 3.4 011 67 5.0 19.5 +-

.6 ;

2.9 15.3 +-

.7 ;

3.5 012 50 5.1 22.8 +-

.7 ;.3.4 18.7 +-

.8.;

3.9 t

013 353 2.0 18.4 4-

.6 ;

2.8 14.2 +-

.7 :;

3.4 014

.341 1.6 18.7 +-

.6 ;

2.8 14.5 +-

.7 ;

3.4

.7.

3.3

.5 2.7 13.6 +-

015 147 10.

17.8 +-

.7 ;

.5 ;;

.7 ; -3.3 2.7

14.0 +-

016 232 0.9 18.2 +-

3.5 017 205 1.6 19.5 +-

.6 ;

2.9 15.3 +-

.7 ;

3.1 018 192 4.2 16.3-+-

.5 ;

2.4 12.1 +-

.6 ;

3.0 019 184 4.2

-15.3 +-

.5 ; '2.3 11.1 +-

.7 ;

3.1 020 165 4.6 16.4 +-

.5 ;

2.5 12.3 +-

.7.;

3.2 021 135 4.4 17.1-+-

.5 l 2.6 12.9 +-

.7 ;

3.5 022 120 4.1 19.6 +-

.6, 2.9 15.4 +-

.7 ;

3.4 2.3 14.3 +-

.6 ; L2.9

.7 ;

023 107

3. 7 '

18.5 +-

3.5

.6 ;

15.4 +-

024 123 13.

19.5 +-

.7 ;

3.3 025 114 12.

18.0 +-

.5 ;

2.7 13.9 +--

. 7 ;-

3.3 026 142 1.8 17.9 +-

.5 ;

2.7 13.7 +-

.7 ;

027 157 2.2 17.5 +-

.5 ;

2.6 13.4 +-

3.3-

.7 ;

3.4-028 171 0.9 18.9 +-

.6 ;

2.8 14.8 +-

.7 ;;

3.3 029 253 1.0 17.8 +-

.5-2.7 13.7 +-

030 270 1.0 MISSINGORDAllAGEDDOSIMETER

.5 2.6' 13.1 +-

.7 ;

3.2 031 292 1.1 17.2 +-

.6 ;

. 7-3.4 2.8 14.3 +-

032 268 4.2 18.4 +-

.7 ;

.5 ;;

3.1 2.4 11.8 +--

033 248 4.3 15.9 +-

.6 ;

3.0

.5 2.3 11.4 +-

034 216 4.1 15.6 +-

.7 ;

.5 ;

3.3 2.6 13.5 +-

035 234 11.

17.7 +-

.7 ;

.5 ;;

3.2 2.5 12.6 +-

036 182 10.

16.7 +-

.7 ;

3.3 i

037 177 10.

17.8 +-

.5 ;

2.7 13.6 +-

.7 ;

3.5 038 323 12.

19.2 +-

.6 ;

2.9 15.0 +-

.7 ;

3.5 039 321 13.

19.3 +-

.6*

2.9 15.1 +-

.7 ;;

3.4 040 323 12.

18.6.+-

.6 ;

2.8 14.5 +-

TRANSIT DOSE =

4.3

+-

.4 ; 1.9 l

59 HATCH

.FOR THE~ PERIOD 831214-840413 TLD DIRECT RADIRTION ENVIRONMENTAL MONITORING RIIMUTH (deg.)

NET AYER. EXPOSURE RATE

  • IN GROUP

<mR/Std.Qir.) t-Std.Dev.

348.75-ll.25 (N) 14.4 +

.4 3

11.25-33.75 (NNE) 14.3 +

.8 2

33.75-56.25 (NE) 15.B +- 2.7 3

56.25-78.75 (ENE) 15.3 +- B.O 1

78.75-10l.25 (E)

NO DRTA+-NO DATR 0

101.25-123.75(ESE) 14.8 +

.B 4

123,75-146.25(SE) 13.3 +

.B 2

14 5.25-158.75 ( 55E )

13.1 +

.7 3

158.75-191.25(5) 13.5 +- 1.5 4

191.25-2l3.75(55H) 13.7 +- 2.3 2

213.75-236.25(SW) 13.B +- 1.4 3

23G.25-258.75(W5W) 12.7 +- 1.4 2

258.75-201.25(W) 14.3 +- 2.0 1

28l.25-303.75(WNW) 13.9 +- 1.2 2

303.75-326.25(NH) 13.9 +- B.O 1

326.25-348.75(NNN) 14.6 +

.9 3

1 DIS 7ANCE(mi) FROM THE REACTOP NET RVER. EXPOSURE RATE

+ IN GROUP

( rnR/ 5t d. Q t r. ) + -S t d. De v.

B-2 14.2 +

.7 9

l 2-5 13.4 +- 1.4 1B

>5 14.8 +- 1.6 11 UPHIND CONTROL DRTA 14.9 +

.4 3

60

. INDIAN POINT TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831215-840420 127 DAYS FIELD TIME 66 DAYS HRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/St d.Qt r.

12.1 + ; Tot.

+- Rdm (deg.)

(mi.)

+- Rdm; Tot.

1.0 ;

4.7

.5 2.7 001 52 1.4 17.7 +-

.6 ;

3.2 17.1 +-

1.1 ;

5.3 u

002 53 1

21.4 +-

.6 ;

3.0 15.1 +-

1.0 5.1 003 61 1.5 19.9 +-

.6 ;

1.0 ;

5.0 2.9 14.7 +-

004 89 1.2 19.6 +-

1.0 ;

.6 ;

2.9 14.4 +-

5.0 1

005 107

.9 19.4 +-

.6 ;

1.1 ;

5.1 3.0 15.4 +-

006 90

.5 20.1 +-

1.1 ;

.6 ;

4 5.2 3.0 15.6 +-

007.

133

.8 20.3 +-

1.1 ;;

.6 ;

5.2 3.1 16.0 +-

008 158

.8 20.6 +-

009 188 1.2 MISSINGORDAbAGEDDOSIMETER 010 206

.9 19.9 +-

.6 ;

3.0 15.1 +-

1.0 ;

5.1 011 170 1.1 19.8 +-

.6 ;

3.0 14.9 +-

1.0 ;

5.1 012.

155

.2.3 19.8 +-

.6 ;

3.0 14.9 +-

1.0 ;

5.1 013 136 3.2 19.2 +-

.6 ;

2.9 14.1 +-

1.0 ;

5.0

.6 3.1 16.5 +-

1.1 j 5.3 014 107 3.1 21.0 +-

.6 ;

2.9 14.1 +-

1. 0,

5.0

  • 015 94 3.8 19.2 +-

.6 ;

3.1 16.5 +-

1.1 ;

5.3 016 142 5.7 21.0 +-

.6 ;

3.0 15.6 +-

1.1 j 5.2-018 147 9.1 20.3 +-

.6 ;

3.1 16.0 +-

1.1,

5.2 019 137

.11.

20.6 +-

020 129 11.

MISSINGORDAbRGEDDOSIMETER 022 74 7.5 20.4 +-

.6 ;

3.1 15.7 +-

1.1 ;

5.2 1.1 5.3 023 5

92 21.0 +-

.6 ;

3.1 16.5 +-

1.0 ;

5.1 024 5

92 20.0 +-

.6 ;

3.0 15.2 +-

1.0 ;

5.1 025 65 4.1 20.0 +-

.6 ;

3.0 15.1 +-

1.1 ;

5.6 026 40 4

23.1 +-

.7 ;

3.5 19.4 +-

1.1 ;

5.3 027 25 5.3 21.2 +-

.6 ;

3.2 16.9 +-

1.1 ;

1 028 24 2.9 20.9 +-

.6 ;

3.1 16.4 +-

5.3 1.1 ;

5.2 029 22 2.1 20.9 +-

.6 ;

3.1 16.4 +-

1.1 ;

030 8

1.9 21.2 +-

.6 ;

3.2 16.9 +-

5.3 1.1 ;

5.2 031 356 5

20.7 +-

.6 ;

3.1 16.1 +-

1.1 ;

j 5.3 032 330 3.7 20.9 +-

.6 ;

3.1 16.4 +-

1.1l5.4 033 338 4.7 21.7 +-

.6 ;

3.2 17.5 +-

1.1 5.5 034 354 7

22.3 +-

.7 ;

3.3 18.3 +-

4 035 297 4.4 20.1 +-

.6' 3.0 15.3 +-

1.1,

5.1 036 309 3.6 MISSINGORDAbAGEDDOSIMETER 037 350 1.1 21.6 +-

.6 ;

3.2 17.3 +-

1.1 ;

5.4 038 337

.9 20.5 +-

.6 ;

3.1 15.8 +-

1.1j 5.2 4

039 315 1

20.0 +-

.6-3.0 15.1 +-

1.0,

5.1 040 294 1.1 MISSINGORDA$AGEDDOSIMETER 041 274 1.1 22.1 +-

.7 ;

3.3 18.0 +-

1.1 j 5.4 042 248 1.5 21.9 +-

.7' 3.3 17.8 +-

1.1,

5.4 i

043 263 2.8 MISSINGORDAbAGEDDOSIMETER i

044 5

92, 19.7 +-

.6 ;

3.0 14.8 +-

1.0l 5.1 l

045 227 2.4 21.0 +-

.6 ;

3.1 16.5 +-

1.1,

5.3 046 209 3.2 20.3 +-

.6 ;

3.0 15.6 +-

1.1j 5.1 047 218 5.3 20.1 +-

.6 j 3.0 15.3 +-

1.1 5.1 g

048 201 4.6 20.1 +-

.6, 3.0 15.3 +-

1.1 5.1 g

049 187 5.2 18.8 +-

.6 ;

2.8 13.5 +-

1.0,

4.9

' TRANSIT DOSE = 8.8

+-

.5 ; 2.2 i

l

61

-INDIAN POINT FOR THE PERIOD 831215-840420 TLD DIRECT RADIATION Et1VIRONMENTAL N0tilTORING i'

RZIMUTH (deg.')

' NET RVER. EXPOSURE RATE'

$ IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-11.25 (N) 16.7 +- 1.3 5

11.25-33.75 (NNE) 16.8 +

.3 3

33.75-56.2d (NE) 16.2 +- 3.7 3

56.25-78.75 (ENE) 15.3 +

.3 3

78.75-lOL.25 (E) 14.7 +

.5 3

10l.25-123.75(ESE) 15.5 +- 1.5 2

123.75-146.25(SE) 15.5 +- 1.0 4

146.25-168.75 ( 55E )

15.5 +

.5 3

168.75-191.25(5) 14.2 +- 1.0 2

151.25-213.75(55N) 15.3 +

.2 3

213.75-236.25(SW) 15.9 +

.9 2

236.25-258.75(WSW) 17.5 +- 3.0 1

258.75-281.25(W) 18.9 +- E.0 1

281.25-303.75(WNW) 15.3 +- B.O 1

303.75-326,25(NN) 15.1 +- 3.0 1

326,25-348.75(NNN) 16.6 +

.8 3

OISTANCE(mt) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/5td.Qtr.)

+-5t d. De v.

B-2 15.7 +- 1.5 15 2-5 16.B +- 1.3 15

>5 15.5 +- 1.3 9

UPNIND CONTROL DATA 15.5 +

.5 2

n 62 KEWAUNEE/PT. BEACH TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831212-840504 144 DAYS FIELD' TIME 92 DAYS HRC LOCATION GROSS NET EXPOSURE RAIE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deh.)

(mi.)

+- Rdm; Tot.

12.5 + ; Tot.

+- Rdm 001 18 8.1

18. 4 + ~-

.6 :

2.8

.7 ;

3.5 002 195 7.0 24.1 +-

.7 ;

3.6-18.1 +-

.9 ;

4.2 1

003 163 4.9 18.8 +-

.6 2.8 12.9 +-

.7 3.5

.7 ;

.8 ;;

004 183 3.3 22.4 +-

3.4 16.4 +-

3.9

.5 ;

005 210 3.2 18.2 +-

2.7 12.4 +-

.7 ;

3.4

.7 ;

006 223 3.7 22.5 +-

3.4 16.5'+-

.8 4.0

.7 ;

007 242 5.7 18.9 +-

.6l-2.8 13.1 +-

.9 l; 3.5 008 202 1.8 23.7 +-

.7 ;

3.6 17.8 +-

4.1 009 180 1.8 22.7 +-

.7 3.4 16.7 +-

.8 4.0

.6 ;

010 158 1.9 19.1 +-

2.9 13.2 +-

.7 3.5

.7 ;

.8 ;;

011 235 1.2 23.2 +-

3.5 17.2 +-

4.0

.7 ;

012 258 1.4 22.1 +-

3.3 16.2 +-

.8 ;

3.9

.6 ;

013 273 1.4 21.7 +-

3.2 15.7 +-

.8 3.9

.7 ;

.8 ;

014 290 0.9 23.1 +-

3.5 17.2 +-

4.0

.9 ;

1.0 ;;

015 342 0.8 29.0 +-

4.4 22.9 +-

4.8

.7 ;

016 342 1.9 22.4 +-

3.4 16.5 +-

.8 ;

3.9

.6 ;

017 317 2.0 21.0 +-

3.1 15.1 +-

.8 ;

3.8

.7 ;

018 310 3.4 23.3 +-

3.5 17.4 +-

.8 ;

4.1 019 293 4.0 22.6 +-

.7 ;

3.4 16.6 +-

.8 4.0

.8 ;

.6 l 3.2 020 273 4.0 21.1 +-

3.2 15.2 +-

3.8

.6 ;

15.5 +-

.8 ;

3.8 021 300 5.6 21.4 +-

.8 ;;

022 316

5. 9 21.4 +-

.6 3.2 15.5 +-

3.8

.7 ;

023 345 2.7 21.9 +-

3.3 15.9 +-

.8 3.9

.6 ;

.8 ;

3.8 024 219 1.3 20.9 +-

3.1 15.0 +-

.7 ;

.8 ;

025 247 1.4 22.6 +-

3.4 16.6 +-

4.0

.6 ;

.8 ;;

026 263 1.3 21.4 +-

3.2 15.5 +-

3.8 027 290 1.4 21.8 +-

.7 ;

3.3 15.8 +-

.8 ;

3.9

.6 ;

028 320 1.3 21.5 +-

3.2 15.6 +-

.8 3.8

.6 ;;

.8 ;

3.8 029 342 1.1 21.2 +-

3.2 15.3 +-

.6 ;

.8lI 030 329 0.6 21.9 +-

.7 3.3 15.9 +-

3.9 031 13 1.0 20.7 +-

3.1 14.8 +-

.8 3.7 032 353 2.1 22.0 +-

.7 ;

3.3 16.0 +-

.8 3.9

.6 ;

.8 ;

033 301 3.9 21.2 +-

3.2 15.3 +-

3.8

.7 ;

3.5 17.7 +-

.8 ;

034 299 8.4 23.6 +-

4.1

.6 ;

3.0 13.9 +-

.8 ;

035 323 3.8 19.8 +-

3.6

.6 ;;

.8 ;

036 336 3.3 21.0 +-

3.2 15.1 +-

3.8

.8 ;

3.7 037 6

3.1 20.5 +-

.6 j 3.1 14.6 +-

.7 ;

038 14 3.7 19.1 +-

.6, 2.9 13.2 +-

3.5

.7 *;

039 13 7.6 19.3 +-

.6 ;

2.9 13.4 +-

.8 l 3.6

.6 3.2 15.7 +-

040 247 4.3 21.7 +-

3.9

.6 ;

.6 l 3.0 14.2 +-

.8 l 3.7

.8*

041 8

23, 20.1 +-

i 042 8

23.

20.0 +-

3.0 14.1 +-

3.7 043 8

23.

19.4 +-

.6 ;

2.9 13.5 +-

.8 ;

3.6 TRANSIT DOSE =

5.6

+-

.5 ; 2.2

63 KEWAUNEE/PT. BEACH-FOR THE PERIOD 831212-840504 TLD DIRECT RADIATION ENVIRONMENTAL MONITORDIG RZIMUTH (dog. )

NET AYER. EXPOSURE RATE.

  • IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-1L.25 (H) 15.3 +- 1.0 2

11.25-33.75 (NNE) 13.5 +

.5 3

33.75-56.25 (NE)

NO DRTA+-NO DATR 0

56.25-78.75 (ENE)

No DATA +-NO DATR 0

78.75-lOL.25 (E)

NO DRTA+-NO DATR 0

18l.25-123.75(ESE)

NO DATA +-NO DATR G

123.75-146.25(SE)

NO DRTA+-No DATR 0

146.25-168. 75 ( 55 E )

13.1 +

.2 2

168.75-191.25(5) 15.2 4-2.3 3

191.25-213.75(55Ni 16.1 4-3.2 3

213.75-236.25(SW) 16.3 +- 1.1 3

236.25-258.75(W5W) 15.4 +- 1.6

.4 258.75-201.25(10 15.5 +

.3 3

281.25-303.75(WNW) 16.3 +- 1.0 C

303.75-326.25(NH) 15.5 +- 1.3 5

326.25-348.75(NNN) 17.0 +- 3.0 6

DISTANCE (mt) FROH THE REACTOR NET RVER. EXPOSURE PATE 4 IN GROUP

( mR/ 5t d, O t r'. ) + -5 t d. De v,

9-2 16.3 +- 2.0 18 E-5 15.2 +- 1.5 15 25 15.1 +- 2.2 7

UPNIND CONTROL ORTA 13.9 +

.4 3

64 LACROSSE TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831209-840423 136 DAYS FIELD TIME 91 DAYS l

NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deg.)

(mi.)

+- Rdm; Tot.

14.4 + ; Tot.

+- Rdm 001 5/

20.

19.7 +-

.6 2.9

.8 ;

3.6

.6 ;;

002 5/

20.

20.1 +-

3.0 14.8 +-

.8 3.7

.8 ;

003 3/

20, 19.8 +-

.6

  • 3.0 14.5 +-

3.6 004 343 3.8 MISSINGORDAllAGEDLOSIMETER 005 313 3.8 26.3 +-

.8 ;

3.9 20.9 +-

.9 4.4

.8 ;

006 291 3.0 20.4 +-

.6 ;

3.1 15.1 +-

3.7

.8 ;

007 261 4.8 20.8 +-

.6 3.1 15.5 +-

3.7

.6 ;;

.8 ;;

008 249 3.2 21.3 +-

3.2 16.0 +-

3.8 009 214 5.0 19.0 +-

.6 ;

2.9 13.7 +-

.7 3.5

.7 ;;

010 171 9.8 18.4 +-

.6 l; 2.8

.6 13.1 +-

3.5 011 176 5.1 19.1 +-

2.9 13.8 +-

.7 3.5

.6 3.0 14.8 +-

.8 ;

012 165 4.9 20.1 +-

3.7

.7 ;;

013 138 3.5 18.9 +-

.6 ;

2.8 13.6 +-

3.5 014 114 4.2 19.4 +-

.6' 2.9 14.1 +-

.8 ;

3.6 015 97 3.9 MISSDIGORDAbAGEDDOSli1ETER 016 94 3.0 21.0 +-

.6 ;

3.2 15.7 +-

.8 3.8

.8 ;

017 105 2.0 22.1 +-

.7 ;

3.3 16.8 +-

3.9

.7 ;

018 52 1.5 18.5 +-

.6 2.8 13.2 +-

3.5

.6 ;

.7 l 3.5 019 16 1.5 18.8 +-

2.8 13.5 +-

3.5 020 1

1.0 18.6 +-

.6 ;

2.8 13.3 +-

.7 ;

021 358 0.5 21.3 +-

.6 ;

3.2 16.0 +-

.8 3.8

.6 ;;

.8 ;;

022 180 0.6 19.8 +-

3.0 14.5 +-

3.6 023 134 1.7 19.9 +-

.6 j 3.0 14.6 +-

.8 3.6 024 58 0.6 21.0 +-

.6, 3.2 15.7 +-

.8 ;

3.8

.8 ;

025 59 3.1 20.1 +-

.6 ;

3.0 14.8 +-

3.7 026 16 1.5 MISSING OR DAMAGED DOSIMETER 027 26 5.1 20.5 +-

.6 ;

3.1 15.2 +-

.8 ;

3.7 028 25 7.0 18.8 +-

.6 2.8 13.5 +-

.7 3.5

.6 ;;

.7 ;;

029 4

4.8 19.0 +-

2.9 13.7 +-

3.5 TRANSIT DOSE =

5.1

+-

.5 ; 2.1 l

l l

I l

65 LACROSSE FOR THE PERIOD 831209-840423 TLD DIRECT RADIATI0t1 Et1VIRONMENTAL MONITORIt1G RZIMUTH (dag.)

NET HYER. EXPOSURE RATE

  • IN GROUP (mR/Std.Qir.) t-Std.Dav.

348.75-ll.25 (N) 14.4 +- 1.5 3

11.25-33.75 (NNE) 14.1 +- 1.0 3

33.75-56.25 (NE) 13.2 +- 0.0 1

56.25-78.75 (ENE) 15.3 +

.6 2

7f 75-10l.25 (E) 15.7 +- 0.0 1

101.25-123.75(ESE) 15.5 +- 1.9 2

123.75-146.25(SE) 14.1 +

.7 2

14 5.25-158.75 ( 55 E )

14.8 4- 0.0 1

158.75-191.25(5) 13.8 4-.7 3

19L,25-2L3.75(55H)

NO DRTR&-NO DRTR 0

213.75-236.25(SW) 13.7 4- 0.0 1

236.25-250.75(H5H) 16.0 +- 2.0 1

250.75-201.25(61) 15.5 +- 2.0 1

281.25-303.75 ( HN H )

15.1 +- 0.0 1

303.75-326.25(NH) 20.9 +- G.0 1

326.25-348.75(NNN)

NO DRTR+-NO DRTR 0

OISTANCE(mt) FRON THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (nR/Std Qtr.) +-5td.Dev.

9-2 14.7 4-1.4 8

2-5 15.3 +- 2.0 11

>5 13.9 +

.9 4

UPNIND CONTROL ORTA 14.8 +

.2 3

66 LA SALLE TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831209-840406 119 DAYS FIELD TIME 86 DAYS NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(de$.)

(mi.)

+- Rdm; Tot.

+- Rdm 16.7 + ; Tot.

001 30 10..

21.0 +-

.6 :

3.1

.9 ;

4.0 l

002 335 4.8 21.7 +-

.7 ;

3.3 17.5 +-

.9 4.1

.6 3.1 16.5 +-

.8 ;

003 343 5.8 20.8 +-

4.0

.6 ;

3.1 16.2 +-

.8 ;

004 38 5.5 20.5 +-

4.0

.6 ;;

.8 ;

005 39 4.3 18.7 +-

2.8 14.3 +-

3.8

.6 3.2 16.8 +-

.9 ;

006 27 3.8 21.1 +-

4.1

.7 ;

.9 ;

007 355 4.1 23.0 +-

3.4 18.8 +-

4.3

.7 ;

.9 ;

008 304 4.6 21.7 +-

3.3 17.5 +-

4.1

.7 ;

3.3

.8 l 4.0 009 292 3.9 22.3 +-

18.0 +-

.9 4.2

.6 ;;

010 276 3.7 20.2 +-

3.0 15.9 +-

.9 ;

011 248 4.0 21.8 +-

.7 3.3 17.6 +-

4.2

.6 ;

.8 ;

012 222 12, 20.6 +-

3.1 16.3 +-

4.0

.7 ;;

.9 ;

013 212 18.

22.1 +-

3.3 17.8 +-

4.2

.9 ;;

014 212 18, 21.7 +-

.7*

3.3 17.5 +-

4.1

.6 l 3.4 i

015 212 18.

20.9 +-

3.1 16.6 +-

.9 4.0

.9 ;

016 215 4.4 22.5 +-

.7 18.2 +-

4.2

.7 ;;

.9 ;;

i 017 204 4.0 21.9 +-

3.3 17.6 +-

4.2 018 173 4.6 22.2 +-

.7 ;

3.3 17.9 +-

.9 4.2

.9 ;-

i 019 174 6.4 21.3 +-

.6 3.2 17.0 +-

4.1

.7 ;;

3.5 18.9 +-

.9 !

4.3 020 158 4.9 23.1 +-

021 125 4.2 24.3 +-

.7 3.6 20.2 +-

.9 ;

4.5

.6 ;

022 114-3.8 21.0 +-

.6 l 3.2 16.7 +-

.9 l' 4.1 023 97 4.5 20.7 +-

3.1 16.4 +-

.8 4.0 j

024 72 4.7 23.1 +-

.7 ;

3.5 18.9 +-

.9 ;

4.3 1

025 41 2.0 21.6 +-

.6 3.2 17.3 +-

.9 ;

4.1 026 13 1.6 21.8 +-

.7 ;

3.3 17.5 +-

.9 '

4.2

.7 ;;

3.4 18.2 +-

.9 l 4.2 027 358 1.5 22.5 + -

028 336 1.6 21.0 +-

.6 ;

3.2 16.7 +-

.9 4.1 029 310 2.3 19.4 +-

.6 ;

2.9 15.0 +-

.8 ;

3.9

.9 !' 4.1 030 301 2.0 21.5 +-

.6-3.2 17.2 +-

031 271 1.7 21.1 +-

.6 !

3.2 16.8 +-

.9' 4.1

.9 l 4.1 I

032 251 1.8 21.5 +-

.6 ;

3.2 17.2 +-

.9 033 227 2.4 22.2 +-

.7 ;

3.3 17.9 +-

4.2

.8,j 3

034 204 1.7 20.2 +-

.6 ;

3.0 15.8 +-

4 3.9 l

035 171 1.6 20.8 +-

.6 3.1 16.5 +-

.9

  • 4.0 036 153 1.8 23.0 +-

.7 ;

.9 l 4.3 3.5 18.8 +-

.9

.6 ';

037 139 2.1 21.5 +-

3.2 17.2 +-

4.1 038 til 1.5 19.9 +-

.6 !

3.0 15.6 +-

.8lI 3.9 l

039 271 0.6 22.0 +-

.7 ;

3.3 17.7 +-

.9 4.2 TRANSIT DOSE =

5.0 +-

.5 ; 2.3 t

l

67 LA SALLE FOR THE PERIOD 831209-840406'-

TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dog.)

NET RVER. EXPOSURE RATE

$ IN GROUP (mR/Std.Qtr.) t-Std.Dav.

348.75-It.25 (N) 18.5 +

.4 2

11.25-33.75 (NNE) 17.1 +

.5 2

33.75-56.25 (NE>

15.9 +- 1.5 3

56.25-78.75 (ENE) 18.5 +- B.0 1

78.75-10l.25 (E) 16.4 +- B.0 1

101.25-123.75(EBE) 16.1 +

.8 2

123.75-146.25(SE) 18.7 +- 2.1 2

146.25-168.75 ( 55E )

18.B 4

.8 2

168.75-191.25(5) 17.2 +

.7 3

19 L.25-213.75 ( 55N) 16.7 4-1.3 2

213.75-236.25(SW) 17.5 +- 1.0 3

236.25-258.75(W5W) 17.4 +

.3 2

258.75-281.25(W) 16.8 +

.9 3

281.25-303.75(WNW) 17.3 +

.7 3

303.75-326.25(NH) 16.3 +- 1.7 2

326.25-348.75(NNN) 16.9 +

.5 3

4 03 STANCE (m1) FR0f1 THE REACTOR NET RVER. EXPOSURE RATE

+ 3H GROUP (mR/5td.Qtr.) +-5td.Devu I

B-?

17.1 +

.9 12 2-5 17.4 +- 1.4 19 f

55 16.5 +

.3 5

1 I

UPNIND CONTROL ORTA 17.3 +

.B 3

1 I

r 68 LIMERICK TLD DIRECT RADIATION ENVIRONMEllTAL MONITORING FOR THE PERIOD 831212-840411 121 DAYS FIELD TIME 106 DAYS I

NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(dea.)

Gai. )

+- Rdm; Tot.

+- Rdm; Tot.

002 13I 17.

MISSING OR DAMAGED DOSIMETER 003 88 3.7 21.7 +-

.7 3.3 16.3 +-

.7 3.2

.7 ;

3.4 17.1 +-

.7 ;

004 52 3.2 22.6 +-

3.3 005 23 3.5 22.4 +-

.7 3.4 16.9 +-

.7 ';

I 3.2 006 8

4.6 24.2 +-

.7 !

3.6 18.4 +-

.7 3.4 I

007 340 7.1 21.5 +-

.6 3.2 16.1 +-

.7 !

3.1 008 330 3.6 22.6 +-

.7 ';

3.4 17.1 +-

.7*

3.3

.7 l 3.4-3.4 17.0 +-

.7 I 009 313 3.3 22.6 +-

3.3

.7l4.0 010 291 4.8 22.9 +-

.7 17.3 +-

3.3 011 303 2.9 29.0 +-

.9 ;

4.3 22.5 +-

.8 I

012 314 1.6 21.6 +-

.6 3.2 16.2 +-

.7, 3.1 013 352 1.7 23.5 +-

.7 I 3.5 17.8 +-

.7 !

3.4

.7 -l 3.1 014 339 1.3 20.7 +-

.6 15.5 +-

.6*

3.0 I

015 47 1.8 23.4 +-

3.5 17.8 +-

.7 3.4 016 71 2.7 24.8 +-

.7 I

.7 *l 3.5 3.7 18.9 +-

.7

.6 l 3.2 017 17

.4 22.3 +-

.7 3.3 16.8 +-

3.2 16.1 +-

.7 l 3.1 018 286

.5 21.5 +-

I 019 276

.6 21.4 +-

.6 3.2 16.0 +-

.7 3.1

.6 ;;

.6lI 020 245

.9 20.9 +-

3.1 15.6 +-

3.1 021 224 1

20.9 +-

.6 3.1 15.6 +-

.6 3.1

.7 ;

022 202 1.2 24.1 +-

.7*

3.6 18.4 +-

3.4 023 172 1.6 MISS!!lGORDAllAGEDDOSIMETER 024 150 1.7 MISSING OR DAMAGED DOSIMETER i

025 132 1.2 23.5 +-

.7 ;

3.5 17.8 +-

.7*

3.4 I

026 120 1.2 23.7 +-

.7' 3.6 18.0 +-

.7 3.4 I

027 160 1

22.1 +-

.7 3.3 16.7 +-

.7 I 3.2 028 91 1

19.9 +-

.6 I 3.0 14.8 +-

.6 l 3.0 029 67

.7 MISSINGORDAllAGEDDOSIMETER 030 146 3.4 26.0 +-

.8' 3.9 19.9 +-

.8*

3.6 031 158 2.8 22.9 +-

.7 I I

3.4 17.3 +-

.7 3.3 I

I 032 152 7.4 22.5 +-

.7 3.4 17.0 +-

.7 3.2 033 184 4.3 19.7 +-

.6 !

2.9 14.6 +-

.6 I 2.9 I

034 201 3.9 21.9 +-

.7*

3.3 16.4 +-

.7 3.2 3

I 035 225 5.1 21.5 +-

.6 3.2 16.1 +-

.7 3.1 I

036 245 4.2 22.4 +-

.7 3.4 16.9 +-

.7 I 3.2 037 266 3.9 18.6 +-

.6 I 2.8 13.7 +-

.6 I 2.8 038 290 15 22.5 +-

.7 l 3.4 17.0 +-

.7 I 3.2 I

039 290 15 22.6 +-

.7 ;

3.4 17.1 +-

.7 3.3 I

040 290 15 24.3 +-

.7' 3.6 18.5 +-

.7 3.5

.6 I

.6 I 041 128 3

18.4 +-

.6 l 2.8 13.5 +-

.6 l 2.8 042 til 4.4 20.6 +-

3.1 15.3 +-

3.0 TRANSIT DOSE =

2.5

+-

.4 ; 1.8 i

t i

i I~

69 LIMERICK FOR THE PERIOD 831212-840411 TLD DIRECT RADIATION ENVIRONtlENTAL t10NITORING RZD1UTH (dog. )

NET AVER. EXPOSURE RATE 4 2N GROUP CmR/Std.Qtr.) t-S t al. Da v.

i 348.75-11.25 (N) 18.1 +

.5 2

i 11.25-33.75 (NNE) 16.5 +

.1 2

33.75-56.25 (NE) 17.4 +

.5 2

56.25-78.75 (ENE) 18.5 +- 5.0 1

78.75-10L.25 (E) 15.E +- 1.1 2

101.25-123.75(ESE) 16.7 +- 1.9 2

123,75-146.35(SE) 17.1 +- 3.3 3

145.25-150.75(SSE) 17.8 +

.3 3

169.75-191.25(5) 14.5 4-B.5 1

19L.25-2L3.75(55N) 17.4 4-1.4 2

213.75-236.25(SW) 15.9 4

.4 2

236.25-258.75(WSW) 16.3 t

.5 2

258.75-281.25(W) 14.5 +- 1.7 2

281.25-303.75(WNW) 18.E +- 3.4 3

303.75-326.25(NH) 16.5 +

.5 2

326.25-348.75(NNN) 16.2 +

.5 3

02 STANCE (mt) FROM THE REACTOR NET RVER.EXP0 Supe RATE

+ 2N GROUP

( mR/ 5t d. Q t r'. ) +-5td.Oh B-2 16.8 +- 1.1 14 2-5 I?.B +- 2.2 17 85 16.4 +

.5 3

UPHINO CONTROL DATA 17.5 +

.5 3

70 MAINE YANKEE TLD DIRECT RADIATION ENVIRONMENTAL NONITORING FOR THE PERIOD 831215-840412 119 DAYS FIELD TIME 95 DAYS NRC LOCAT10N GRUSS NET EXPO!URE RATE STATION AZIltVTH/DIST EXPOSURE (mR) mR/Std 0tr.

(deg.)

(mi.)

+- Rda 20.6 +; Tot.

+- Rdm

.6 3.1 14.3 + ;Tc't.

002 6

1.4

.6,j 1.1 4.8 3.0 13.8 +-

1.0 *;

003 23 1.5 20.1 +-

4.7 4

004 44 1.8 19.0 +-

.6' 2.8 12.8 +-

1.0 I 4.6

.6 *!

3.0 005 116

.5 20.1 +-

1.1l4.8

.6 13.8 +-

1.0 4.7 006 168 1

20.6 +-

3.1 14.3 +-

007 185 1.6 19.0 +-

.6 I 2.8 12.8 +-

1.0 I 4.6 i

008 195 2.3

.19.7 +-

.6 I 2.9 13.4 +-

1.0 I 4.7 009 209 3.8 19.6 +-

.6 I I

2.9 13.4 +-

1.0 4.7 I

010 310 1.7 19.1 +-

.6 2.9 12.9 +-

1.0 I 4.6 i

011 290 1.8 21.9 +-

.7 3.3 15.6 +-

1.1 4.9 I

I 1

012 275 1.7 21.2 +-

.6 I 3.2 14.9 +-

1.1 I 4.8 1

I 013 256 1.9 19.3 +-

.6 2.9 13.1 +-

1. 0 l
4. 7 014 232 2.5 19.8 +-

.6 I 3.0 13.5 +-

1.0

  • 4.7 015 22' 5.3

-19.5 +-

.6 I 2.9 13.3 +-

1.0 I 4.7 l

016 24e 4.4 21.3 +-

.6 I I

3.2 14.9 +-

1.1 4.8 017 250 6.6 26.9 +-

.8 I I

4.0 20.2 +-

1.2 5.4 018 268 4.7 20.8 +-

.6 I I

3.1 14.5 +-

1.1 4.8 i

i 019 283 4.4 19.1 +-

.6 I 2.9 12.9 +-

1.0 I 4.6 1

020 305 4.7 18.2 +-

.5 I 2.7 12.0 +-

1.0 I 4.6

)

021 300 2.9 19.6 +-

.6 I 2.9 13.4 +-

1.0 I 4.7 I

022 332 2.7 21.6 +-

.6 3.2 15.3 +-

1.1 4.9 I

023 20 3.9 20.6 +~

.6 3 3.1 14.3 +-

1.1 I 4.8 i

024 23 3

20.6 +-

.6 I I

3.1 14.3 +-

1.1 4.8 t

j 025 42 4.7 20.2 +-

.6 3.0 13.9 +-

1.0 I I

4.7

.6 l 2.7 1

026 60 15 18.3 +-

I

.5 f2.1 +-

1.0 4.6 l

1 027 62 16.

18.6 +-

2.8 12.4 +-

1.0 I 028 63 16.

19.2 +-

.6 *;

4.6 2.9 13.0 +-

1.0 I 4.7-029 64 2.1 22.6 +-

.7 I 3.4 16.2 +-

1.1 I 5.0 030 84 1.5 21.4 +-

.6 I 3.2 15.0 +-

1.1 I 4.8 1

031 115 1.6 19.5 +-

.6 I 2.9 13.3 +-

1.0 I 4.7 032 135 2

19.0 +-

.6 I 2.8 12.8 +-

1.0 I 4.6 I

033 66 3.5 20.2 +-

.6 3.0 13.9 +-

1.0 I I

4.7 1

034 97 4.9 21.0 +-

.6 3.1 14.7 +-

1.1 I 4.8 j

035 123 4.8 22.0 +-

.7 I 3.3 15.6 +-

1.1 I 4.9 j

036 140 4.9 21.2 +-

.6 I 3.2 14.9 +-

1.1 I 4.8 1

037 151 6

20.8 +-

.6 I 3.1 14.5 +-

1.1 I 4.8 i

038 152 4.2 22.2 +-

.7 I 0.3 15.8 +-

1.1 I 4.9 J

039 172 4.9 20.6 +-

.6 I 1.1lI 3.1 14.3 +-

4.8

{

040 156 7.4 21.6 +-

.6 l 3.2 15.3 +-

1.1 4.9 TRAtl$IT DOSE =

5.5

+-

.9 ; 4.0 l

t 4

f I

i l

l l

71 MAlllE YAllKEE FOR THE PERIOD 831215-840412 TLD DIRECT RADIATI0tl EtiVIR0tlHEllTAL N0tilTORIllG AZD1U TH ( deg. )

NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dav.

348.75-11.25 (N) 14.3 +- 0.0 1

~

t1.25-33.75 (NNE) 14.1 +

.3 3

33.75-56.25 (NE) 13.3 +

.8 2

56.25-78.75 (ENE) 15.1 +- 1.6 2

78.75-101.25 (E) 14.8 +

.3 2

10t.25-123.75(EBE)

14. 2 +- 1.2 3

123.75-146.25(SE)

13. 8 +- 1.5 2

146.25-lGO.75(55E) 15.8 4-.7 4

160.75-191.25(5) 13.5 4-1.1 2

19t.25-2t3.75(55H) 13.1 4-

.6 2

213.75-236.25(SW) 13.4 4-.2 2

236.25-250.75(64S64)

IG.t +- 3.7 3

25 0.75-201. 25 ( H )

14.7 +

.3 2

~

20 t.25-303.75 ( 64N64) 13.9 +- 1.4 3

303.75-32G.25(NH) 12.4 +

.8 2

326.25-340.75(NNH) 15.3 +- 0.0 t

1 DISTANCC(mt) FROM THE REACTOP NCT HVER.EWPOGUPC PATC

+ IN GROUP (nR/Gtd.0tt.) 4-5td.Dev, 9-2 13.8 +- 1.0 13 2-5 14.3 +- 1.1 19 85 15.8 +- 3.1 4

UPHINO CONTROL ORTA 12.5 +

.5 3

72 MCGUIRE TLD DIRECT RADIATION EliVIRONMENTAL N0ti! TOR!ilG FOR THE PERIOD 831213-840411 120 DAYS FIELD TIME 90 DAYS HRC LOCATI0tt GROSS HET EXPO!URE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deg.)

(mi.)

+- Rdmliot.

+- Rdm 001 97 0.5 18.7 +-

.6*

2.8 12.2 + ; Tot..8*

3.6 002 323 1.6 20.0 +-

.6 I I

3.0 13.5 +-

.8 l 3.8

.8 I

003 336 1.7 22.6 +-

.7 3.4 16.0 +-

4.1 004 303 2.9 HISSINGORDAl1AGEDDOSINETER 005 321 3.9 19.3 +-

.6*

2.9 12.7 +-

.8*

3.7 006 334 3.7 19.9 +-

.6 I 3.0 13.3 +-

.8 I 3.7 007 352 3.5 19.0 +-

.6 I I

2.9 12.5 +-

.8 3.6 008 287 2.0 20.6 +-

.6 I I

3.1 14.1 +-

.8 3.8 009 273 1.9 19.3 +-

.6 I I

2.9 12.8 +-

.8 3.7 010 244 1.7 18.8 +-

.6 I I

2.8 12.2 +-

.8

.7 l 3.6 I

011 225 2.1 18.4 +-

.6 2.8 11.8 +-

3.6 012 212 3.6 HISS!HGORDAl1AGEDDOS! METER 013 232 4.4 26.7 +-

.8 '

4.0 20.1 +-

.9*

4.6 I

014 253 3.7 22.6 +-

.7 I 3.4 16.1 +-

.8 I 4.1 015 261 4.2 18.5 +-

.6 I I

2.8 12.0 +-

.8 3.6 I

I 016 288 4.3 25.4 +-

.8 3.8 18.8 +-

.9 4.4 017 289 16.

27.1 +-

.8 I I

4.1 20.6 +-

1.0 4.7

.6 l 3.8 I

018 287 2.0 25.2 +-

.8 18.7 +-

.9 4.4 l

019 286 16.

26.1 +-

.9lI 3.9 19.6 +-

4.5 I

i 020 233 17, 26.3 +-

.8 3.9 19.7 +-

.9 4.5 021 204 10.

HISSING OR DAllAGED DOS!!!ETER i

i 022 239 9.5 20.4 +-

.6*

3.1 13.9 +-

.8*

3.8 I

023 115 4.9 17.4 +-

.5 2.6 10.9 +-

.7 I 3.5 024 132 4.9 18.0 +-

.5 I 2.7 11.4 +-

.7 I 3.5 I

025 156 4.0 15.3 +-

.5 2.3 8.7 +-

.7 I I

3.2 026 175 3.7 18.1 +-

.5 2.7 11.5 +-

.7 I 3.5 027 198 4.3 21.3 +-

.6 !

3.2 14.7 +-

.8 I 3.9 I

028 169 12.

18.3 +-

.5*

2.7 11.7 +-

.7 3.6 I

I 029 155 12.

19.0 +-

.6 2.3 12.4 +-

.8 3.6 I

I

.i 030 146 13.

17.7 +-

.5 2.7

!!.2 +-

.7 3.5 I

i 031 143 1.9 17.8 +-

.5 2.7 11.3 +-

.7 I 3.5 032 155 1.3 18.9 +-

.6 I 2.8 12.4 +-

.8 !

3.6 033 178 1.6 18.1 +-

.5 I 2.7 11.5 +-

.7 ;

3.5 034 108 2.0 MISS!HGORDAllAGEDDOSINETER 035 93 2.2 17.5 +~

.5*

2.6 11.0 +-

.7' 3.5 I

036 68 2.5 17.8 +-

.5 2.7

!!.3 +-

.7 I 3.5 037 82 4.7 18.9 +-

.6 I 2.3 12.4 +-

.8 I 3.6

.6 *!

2.3

.6 12.2 +-

.8 I 038 64 4.9 18.8 +-

3.6 3.2 15.0 +-

.8 I 4.0 1

039 42 5.0 21.6 +-

040 26 4.3 18.8 +-

.6 I

.7ll3.4 2.3 12.2 +-

.8 3.6 041 42 2.0 16.8 +-

.5 I 2.5 10.2 +-

042 21 1.6 20.3 +-

.6 I 1

3.0 13.7 +-

.8 3.8 043 8

2.6 HISS!HGORDAllAGEDDOSINET6R 044 37/

13.

HIS$ltlG OR DAllAGED DOS! HETER 045 78/

18.

HIS$1HG OR DAMAGED 0051ltETER l

046 94/

18, 23.0 +-

.7 ;

3.5 16.5 +-

.9 ;

4.1 TRANSIT D03E =

6.5

+-

.5 ; 2.3 1

73 MCGUIRE i

FOR THE PERIOD 831213-840411 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING l

RZIMufH (deg. )

NET RYCR. CXPOSURC RRfC 4 IN GROUP (mR/Std.0tr.) t-End.Dow.

i l

l 340.75-11.25 (N) 12.5 +- 8.0 1

11.25-33.75 (NNC) 13.0 +- 1.1 2

33.75-54.25 (NC) 12.5 +- 3.4 2

56.25-78.73 (CNC)

!!.E +

.7 2

70.75-104.35 (C) 13.R += 2.4 4

101.25-123.75(CBC) 19.5 +- 3.0 1

123.75-146.25(SC) lL.5 +

.1 3

l 146.25-159.75(55C) 11.2 4-2.1 3

155.75-151.25(5) lL.5 4

.1 3

15L.25-It3.75(55H) 14.7 4-5.5 1

213.75-236.25 t SW) 17.2 4-4.7 3

336.25-250.75(W5W) 14.1 +- 1.9 3

f 1

1 358.75-201.25tW) 12.4 +

.I a

Is i. 25-3ea.75 (WNW1 18.5 +- 3.4 2

I 303 ?S-328.25(HN) 13.1 +

.S 2

i 326.tS-340.75fNNN) 14.7 += 1.9 2

i i

l i

l 4

I DIlfMNCC(mt) FROM DE PCACfo#

NCT MVCR.CNPo6UPE PMTC

+ IN GROUP

~

(mR/StdiQtr.) 6-Bid.Dav, B-2 12.7 +- 1.8 11 i

l I-5 13.1 += 8.9 il J

>5 14.8 += 3.3 4

UPHIND CONTROL DATA 19.5 +- 1.0

)

I 4

74 HILLST0 tie TLD PIRECT RADIAT!0ll EtiVIR0tir1EllTAL N0ti! TOR!llG FOR THE PERIOD 831215-840413 120 DAY 3 FIELD TIME 92 DAYS t1RC LOCATI0lt GROSS tlET EXP0tVRE RATE STATI0ll AZIttVTH/DIST EXPOSURE (mR) mR/Std.0tr.

(deg.)

(mi.)

+- Rdm

+- Rdm 22.8 +; Tot.

11. 0 + ; Tc t.

001 0

1

.7*

3.4

.8' 4.6 002 24 1.3 19.4 +-

.6 I 2.9 7.7 +-

.7 I 4.2 003 47 1.5 22.9 +-

.7 I 3.4 11.2 +-

.8 I 4.6 004 60 1.7 21.4 +-

.6 I 3.2 9.7 +-

.8 I 4.4 005 85 1.3 22.7 +-

.7 I 3.4

!!.0 +-

.8 I 4.6 006

!!0 1.8 21.3 +-

.6 I 3.2 9.6 +-

.8 I 4.4 007 67 5.3 22.6 +-

.7 I I

3.4 10.9 +-

.8 4.6

.7 *l 3.4

.7 10.9 +-

.8 I 008 49 5.3 22.6 +-

4.6 3.3 10.4 +-

.8 1 009 84 5.2 22.1 +-

4.5 0!!

232 2.5 21.2 +-

.6 I 3.2 9.5 +-

.8 I 4.4 012 256 2.4 23.6 +-

.7 I I

3.5 11.8 +-

.8 4.7 013 274 2.2 23.0 +-

.7 !

3.4 11.2 +-

.8 4.6 I

.7 3.4 10.8 +-

.8 I 014 295 1.9 22.6 +-

.6 ;

4.6 2.9 7.7 +-

.7 I 015 315 1.5 19.4 +-

4.2 016 339 1.2 23.8 +-

.7 I 3.6 12.0 +-

.8 I 4.7 017 353 3.5 22.0 +-

.7 I 3.3 10.2 +-

.8 I 4.5 018 24 3.5 22.2 +-

.7 I

3. 3 10.5 +-

.8 I 4.5 i

4 019 33 3

24.4 +-

.7 I 3.7 12.6 +-

.9 1 4.8 020 82 4

23.1 +-

.7 l 3.5 11.4 +-

.8 I 4.6 022 59 3.7 23.4 +-

.7' 3.5 11.6 +-

.8 I 4.6 028 257 5.8 23.0 +-

.7 I 3.4 11.2 +-

.8 I 1

4.6

.7 l 3.7 029 272

3. 7 25.0 +-

.7 13.2 +-

.9 I 4.8 a

030 295 3.5 23.5 +-

3.5 11.7 +-

.8 I 031 317 3.6 21.7 +-

.6 *:

4.7 3.2 9.9 +-

.8 I 4.5 032 327 4.3 25.1 +-

.8 I 3.3 13.3 +-

.9 I 4.8 1

033 41 4.7 23.1 +-

.7 I

3. 5 11.4 +-

.8 I 4.6 i

034 54 5.5 23.8 +-

.7 I 3.6 12.1 +-

.8 I 4.7 037 354 6.8 23.3 +-

.7 I 3.5 11.5 +-

.8 I 4.6 039 1

5.7 22.9 +-

.7 I 3.4 11.2 +-

.8 I 4.6 4

040 278 8.7 19.8 +-

.6 I 3.0 8.1 +-

.8 I 4.3 041 34 29.6 +-

.9 I 4.4 17.7 +-

1.0 !

5.4 i

042 84 8

22.7 +-

.7 I 3.4 10.9 +-

.8*

4.6 046 41

.6 22.5 +-

.7 I 3.4 10.7 +-

.8 I 4.5

.8 l 4.0 I

i 048 4

40 26.9 +-

.8 15.0 +-

.9 l 5.0 049 4

40 26.3 +-

i

3. )

14.5 +-

.9 5.0 TRAllSIT LOSE =

11.5

+-

.5 ; 3.2

(

l i

75 HILLST0tlE FOR THE PERIOD 831215-840413 TLD DIRECT RADIAT10ti EtiVIR0tiMEHTAL M0tilTOR!t4G FClfiUTH (deg. )

NET AVER. CXPOSURE RATE

$ 2N GROUP (mR/Std.Qtr.) t-Std.Dev.

340.75-18.25 t ri) 11.0 +

.5 4

!!.25-33.75 (f4NE) 10.3 +- 2.5 A

33.75-56.25 (NC) 12.3 +- 2.7 6

56.25-70.75 (ENE) 10.7 +- 1.0 3

70.75-106.25 (E) 10.8 +

.4 4

106.25-123.75tEDCI 9.6 +- 0.0 1

12 3. 75 - 146. 25 ( S C )

NO DATA *-N0 DATA 0

146.25-160.75t55El NO DHTH&-NO DOTH O

~

160.75-191.2515)

NO Dnin&-N0 Uf1TH O

196.25-213.75(55HP NO DHTH&-NO Dfiffi O

213.75-236.25tGH) 9.5 +- 0.0 1

2 36. 25 -250. 751 H'.lW )

18.5 +

.4 2

250 75-201.25tH) 10.8 +- D.6 3

'~

201. 2 5-303. 75 ( HHH )

18.3 +

.8 2

303.75-326,25tNH) 0.0 4-l.B 2

326.25-340.75if4NH1 12.7 +

.3 2

O!GTHNCCIa e > FP0H THE P4hcit.f<

NCT hyt:R E WGCul< feelTC 4 IN GiJ00P iRFd id J tr.> + -9 td, q,yu 0-2 10.1 +- 1.5 10

~

g.g 14.4 4-1.2 13

~

85 ll.5 += 2.4 10

~

~

UPHIND C6HTP0L Ufiin 14.0 4-

.4 2

76 MONTICELLO TLD DIRECT RADIAT!05l EllVIRONMENTAL MONITORING FOR THE PERIOD 831212-840412 122 DAYS FIELD TIME 92 DAYS HRC LOCATION GROSS HET EXPOSURE RATE STAT!0tl AZIMUTH /DIST EXPOSVRE(mR) mR/Std.0tr.

1 (deo. )

(mi.)

+- Rdm; Tot.

+- Rda

.6 2.8 14.0 + ; Tot.

001 133 3.6 18.9 +-

.6 ;

.7' 3.4 3.1 15.6 +-

.8 I 002 163 4.6 20.6 +-

.6 ;

3.6 003 183 4.1 20.0 +-

?.0 15.1 +-

.7 I 3.5 004 206 4.3 20.0 +-

.6 I 3.0 15.1 +-

.7 I 3.5 005 230 4.2 19.6 +-

.6 I 2.9 14.7 +-

.7 I 3.5 006 253 4.6 20.6 +-

.6 3 3.1 15.6 +-

.8 I 3.6 007 269 4.4 19.1 +-

.6 I I

2.9 14.2 +-

.7 3.4 008 286 4.0 19.2 +-

.6 I 2.9 14.3 +-

.7 I 3.4 009 274 1.9 19.5 +-

.6 I 2.9 14.6 +-

.7 I 3.5 010 244 1.3 17.9 +-

.5 I 2.7 13.0 +-

.7 I 3.3 I

011 226 0.9 18.4 +-

.6 2.8 13.5 +-

.7 I 3.4 012 181 1.8 19.0 +-

,6 I 2.8 14.1 +-

.7 I 3.4 013 137 1.7 18.9 +-

.6 I 2.8 14.0 +-

.7 I 3.4 014 155 1.0 19.1 +-

.6 I 2.9 14.2 +-

.7 I 3.4 015 208 0.5 18.5 +-

.6 I 2.3 13.6 +-

.7 I 3.4 016 284 2.0 18.8 +-

.6 I 2.8 13.9 +-

.7 I 3.4 017 113 1.6 18.4 +-

.6 I 2.3 13.5 +-

.7 I 3.3 018 85 1.1 18.4 +-

.6 I 2.3 13.5 +-

.7 I 3.3 I

019 63 1.2 18.6 +-

.6 2.8 13.7 +-

.7 I 3.4 020 37 1.7 19.4 +-

.6 I 2.9 14.5 +-

.7 I 3.5 021 23 0.8 18.6 +-

.6 I 2.3 13.7 +-

.7 I 3.4 022 354 0.7 18.6 +-

.6 I I

2.3 13.7 +-

.7 3.4 I

023 338 0.8 17.8 +-

.5 2.7 13.0 +-

.7 I 3.3 024 307 1.8 17.9 +-

.5 I 2.7 13.0 +-

.7 I 3.3 025 339 4.1 18.7 +-

.6 I 2.3 13.8 +-

.7 I 3.4 026 320 4.6 19.3 +-

.6 I I

2.)

14.4 +-

.7 3.5 I

027 354 4.5 18.8 +-

.6 2.3 13.9 +-

.7 I 3.4 028 17 3.7 17.4 +-

.5 I 2.6 12.6 +-

.7 I 3.2 029 50 4.0 17.6 +-

.5 I 2.6 12,7 +-

.7 I 3.3 030 77 3.6 18.9 +-

.6 I

. 7 lI 2.3 14.0 +-

3.4 031 115

3. 3 22.3 +-

.7 I 3.3 17.3 +-

.8 3.8 032 90 4.6 MISS!!iG OR DAl'1 AGED DOSIMETER 03) 323 15.

19.7 +-

.6 3.0 14.8 +-

.7' 3.5

.5lI' 2.7 13.3 +-

.7 I 034 323 15.

18.2 +-

3.3 035 323 15.

19.1 +-

.6 2.3 14.2 +-

.7 l 3.4 TRAH5IT DOSE =

4.6

+-

.5 i 2.0 i

e

77 t10tiTICELLO FOR THE PERIOD 831212-840412 TLD DIRECT RADIAT10tl EllVIR0llt1EtiTAL f10tlITORIllG RZD1UTH (deg.)

f1ET AVER. EXPOSURC RATE

$ If4 GROUP (mR/Std.Ctr.) t-Std.Dav.

340.75-11.25 ( fi) 13.0 +

.2 2

11.25-33.75

( firit )

13.1 +

.5 2

33,75-56.25

( fit )

13.8 +- 1.3 2

56.25-78.75 (Ef4C) 13.9 +

.2 2

78.75-101.25 (E) 13.5 *- 0.0 1

108.25-123.75(EBC) 15.4 +- 2.7 2

123.75-146.25190) 14.0 +

.0 2

146.25-lGO.75(5GC) 14.9 4-1.0 2

10 0. 75 - 191.2 5 ("a )

14.6 4-.7 2

19 6.25-213. 75 ( 5 G H )

14.4 4-1.0 2

213.75-23G.25tGH) 14.1 +

.9 2

2 3G.25-250. 75 t 64964)

14. 'l +- 1. 9 2

250.75-201.25164) 14.4 +

.2 2

20 8,25-303.75 t 64t464) 14.1 +

.2 2

103.75-326,25tf4N) 13.7 +- 1.0 2

326. 25 -34 0. 751 FA PJ H )

13.4 +

.6 2

=

O!GTAf4CCime> FP0H THE feCACTOP tlET ftVER.CMPOSUPC PATC

+ Ifi GROUP i nRf GAMir.4 7 +-Sid 0c m 4

0-2 13.7 +

.5 18

~

2-5 14.5 4-1.2 15

~

35 fl0 DftTA*-f40 DAf ri 0

~

UPHlfl0 CorifR6L OftTA 14.t +

.B 3

h

78 tiORTH AtiliA TLD DIRECT RADIATI0ft ENVIR0tli1EllTAL l10f1ITORIllG FOR THE PERIOD 831214-840411 119 DAYS FIELD TIME 84 DAYS tlRC 1.0 CAT!0tl GROSS tlET EXPO!VRE RATE STATION AZIt1VTH/DIST EXPOSVRE(mR) mR/Std.0tr.

(deo.)

(mi.)

+- Rdm

+- Rdm 24.3 +; Tot.

19.7 + ; Tot.

001 243 1.8

.7 ;

3.6

.9 ;

4.6 002 263 1.6 20.9 +-

.6 3.1 16.1 +-

003 296 1

21.6 +-

.6 ;

.9 4.1

.9 ;

3.2 16.8 +-

004 311 1.3

'25.1 +-

.8 ;

4.2 3.3 20.6 +-

1.0 ;

4.7 1.0 ;;

005 329 1.3 24.3 +-

.7' 3.6 19.7 +-

4.6

.7 l 3.5 006 231 3.9 24.2 +-

.7 3.6 19.6 +-

.9 ;

4. 6 007 224 1.7 23.3 +-

18.6 +-

.9 008 210 1.6 22.2 +-

.7 ;

.9 l 4.4 3.3 17.5 +-

4.3 009 181 1.4 20.3 +-

.6 !

3.0 15.5 +-

.8, 4.0 010 155 1.'

28.4 +-

.9*

4.3 24.1 +-

1.1 5.1 I

011 136 1.6 21.6 +-

.6 I I

3.2 16.9 +-

.9 4.2

.6 ;! 3.4 012 163 3.5 22.6 +-

.7 17.9 +-

.9 !

4.3 013 190 3.3 21.1 +-

3.2 16.3 +-

.9 4.1 014 205 4.9 20.9 +-

.6*

3.1 16.1 +-

.9 l 4.1 I

015 140 4.2 22.4 +-

.7 3.4 17.7 +-

.9, 4.3

3. 7 20.0 +-

1.0 ';

. 7 l3 016 113 4.9 24.5 +-

4.6 017 93 3.3 20.5 +-

1

.6 3.1 15.6 +-

.9 4,t 018 64 4.1 19.9 +-

1.1 ;l 4.0

.6 3.0 15.0 +-

019 78 2.7 28.7 +-

.9 ;

.8 4.3 24.4 +-

5.2

.7 l 3.0 1

020 97 1.9 23.7 +-

3.6 19.1 +-

.9 4.5

.6 ;

15.5 +-

.8 ;

021 105 1.7 20.3 +-

4.0

.9 !'

4.2 022 60 2.4 21.4 +-

.6 3.2 16.6 +-

.7 ;

023 37 1.4 23.0 +-

.8 ;

3.4 18.3 +-

.9 :

4.4 024 16 1.6 25.9 +-

3.9 21.5 +-

1.0l 4.8 025 48

3. 5 19.1 +-

.6 ;

2.9 14.1 +-

.8 ;

3.9 026 17 3.7 23.0 +-

.7 !

3.5 18.4 +-

.9 4.4 027 3

4.8 20.7 +-

.6 ;

3.1 15.9 +-

.9 ;

4.1

.9 ;;

028 348 4

21.5 +-

.6 3.2 16.7 +-

.6 ;;

4.2 029 2

1.9 21.0 +-

3.2 16.2 +-

.9-4.1 j

030 284 5

21.2 +-

.9 *!

4.1

.6 3.2 16.4 +-

031 310 4.7 23.0 +-

. 7 ;'

.9 3.5 18.4 +-

4.4 i

032 273 4.9 17.1 +-

.5 I 2.6 12.0 +-

.8 !

3.6 033 257 5.1 21.4 +-

.6 !

3.2 16.6 +-

.9*

4.2 034 242 7.1 24.5 +-

.7 3.7 20.0 +-

1.0 !

4.6 025 255 11.

22.0 +-

.7 l

3. 3 17.3 +-

.9*

4.3 036 248 15, 21.6 +-

.6 l 3.2 16.8 +-

.9 I 4.2 037 247 17, 21.3 +-

.6*

3.2 16.5 +-

.9 I 4.2 i

038 244 19, 21.3 +-

.6 l 3.2 16.5 +-

.9 l 4.2

]

TRAll3!T DOSE =

5.9

+-

.5 ; 2.2 i

i l

l

79

-NORTH ANNA FOR THE PERIOD 831214-840411

-TLD DIRECT RADIATION ENVIRONMENTAL MONITORING MZIMUTH ' Ceteg. )

NET MVER. EXPOSURC RMTC 4 !N GROLY' (mR/Std.Qtr.) +-Std.Dev.

340.75-11.25 (N)

L6.1 +

.2 2

11.25-33.75 (NNC) 45.5 t-2.2 2

23.75-58.25 (NE) 49.2 +- 2.0 2

56.25-79.75 (ENC) 19.7 +- 5.0 3

78.75-191.25 (E)

!?.4 +- 2.5 2

101.25-123. '5 (ESE) 17.7 +- 3.2 2

123,75-146.25(SC) 17.3 +

.6 2

145.25-185.75(55E) 21.5 +- 4.4 2

3E9,75-19L.25(E) 15.9 +

.E 2

191.25-21J.75(SSN) 18.0 +- 1.0 2

213.75-236.25(SN) 19.1 +

.7 2

216.25-250.75(NSN) 18.4 +- f.7 4

250.75-26t.29tW) 14.1 +- 2.9 2

as t.25-303. 75 ( HNe4 )

L5.5 +-.3 2

253.73-22E.25(NHA 19.5 +- 3.E 2

22G.25-24G.75(NNH) 19.2 +- 2.8 2

DISTRNCC(ml) FROM THE REACTOR PgggE Pf5g{gE 4 IN GPOUP 0-2 I B.4 +- L.4 15

~

2-5 L?.t +- 2.7 17

>l 17.9 +- 1.0 3

UPHIND CONTPOL DMTM 15.5 t-.2 3

OCONEE TLD DIRECT RADIATION ENVIRONt1 ENTAL MONITORING FOR THE PERIOD 831214-840504 142 DAYS FIELD TIME; 84 DAYS NRC LOCATION

-GROSS NET EXPOSURE RATE STfEON AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.

(dea.)

(mi.)

+- Rdm; Tot.

24.4 + ; Tot.

+- Rdm 001 158 7.5 27.5 +-

.8 ;

4.1 1.0 ;

5.0 002 133 4.9 27.4 +-

.8 ;

4.1 24.3 +-

1.0 ;

4.9 003 119 4.3 25.4 +-

.8 ;

3.8 22.2 +-

1.0 4.7 1.0 ;

004 84 4.7 27.6 +-

.8 ;

4.1 24.5 +-

5.0 005 65 4.0 25.8 +-

.8 ;

3.9 22.6 +-

1.0 ;

4.7 006 52 1.8 27.7 +-

.8 4.2 24.7 +-

1.0 ;

5.0 007 22 3.5 27.4 +-

.8 ;

4.1 24.3 +-

1.0 4.9

.8 ;

1.0 ;

008 33 1.4 25.6 +-

3.8 22.4 +-

4.7

.7 ;

009 52 1.8 22.7 +-

3.4 19.2 +-

.9 ;

4.3

.6 ;

010 66 1.2 19.0 +-

2.9 15.3 +-

.8 3.8

.8 ;;

011 107 1.9 21.7 +-

.6 ;

3.2 18.2 +-

4.1 012 87 1.0 26.8 +-

.8 ;

4.0 23.6 +-

1.0 4.9 1.0 ;;

013 142 0.7 25.6 +-

.8 '

3.8 22.4 +-

4.7 014 166 0.7 MISSING OR DAllAGED DOSIMETER 015 226 1.7 23.7 +-

.7 3.5 20.3 +-

.9 4.4 016 207 1.4 24.9 +-

.7 ;

.9 ;;

3.7 21.7 +-

4.6 017 182 09 91.9 +-

.7 3.3 18.4 +-

.7 ;;

.9 4.2

.9 ;;

018 186 3.8 22.7 +-

3.4 19.2 +-

4.3 019 155 4.1 24.9 +-

.7 ;

3.7 21.7 +-

.9 ;

4.6 020 203 8.4 19.8 +-

.6 ;

3.0 16.1 +-

.8 ;

3.9 021 210 4.6 22.7 +-

.7 ;

3.4 19.2 +-

.9 :

4.3 022 227 4.8 23.1 +-

.7 ;

3.5 19.7 +-

.9 ;

4.3 023 240 3.6 23.7 +-

.7 3.6 20.4 +-

.8 ;

.9 4.4 1.0 ;;

024 268 3.6 26.6 +-

4.0 23.4 +-

.6 ;

4.8 025 257 1.9 21.4 +-

3.2 17.9 +-

.7 ;;

.8 4.1 3.5 20.3 +-

.9 ;

026 293 3.6 23.6 +-

4.4

.8 ;

027 311 3.5 20.1 +-

.6 3.0 16.5 +-

028 288 2.0 20.7 +-

.6 ;

3.9 3.1 17.2 +-

.8 ;

4.0

.7 ;

.9 ;

029 275 1.8 22.0 +-

.7' 3.3 18.6 +-

4.2 3.4 19.2 +-

.9 ;

030 321 1.8 22.7 +-

031 344 2.0 22.1 +-

.7 ;

4.3

.9 ;;

3.3 18.6 +-

.9 ;

4.2 032 336 3.7 28.7 +-

4.3 25.7 +-

1.0 ;

5.1 033 358 4.5 MISSING OR DAMAGED DOSIMETER 034 256 9.4 29.6 +-

.9 4.4 26.7 +-

1.1 ;

5.3

.8 ;;

035 149 21.

25.7 +-

3.9 22.5 +-

1.0 ;

4.7 036 126 8.0 97.2 +-

.8 ;

4.1 24.1 +-

1. 0 ~

4.9 1.0 ;

037 96 9.7 26.7 +-

.8 4.0 23.6 +-

1.0 ;

4.8 1.2 ;

038 32/

15.

32.7 +-

4.9 30.0 +-

.8 ;

5.7 1.0 ;

039 31/

15.

27.3 +-

4.1 24.2 +-

.9 ;;

4.9 040 29/

15.

30.9 +-

4.6 28.0 '-

1.1 ;

TRANSIT DOSE =

4.7 +-

.5 ; 2.1 5.4

81 OCONEE FOR THE PERIOD 831214-840504 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RIIMUTH (dag.)

NET AVER. EXPOSURE RATE

$ IN GROUP (mR/Std.Qtr.) t-S t d. De v'.

348.75-1L.25 (N)

NO DRTA+-NO DATR 0

11.25-33.75 (NNE) 23.3 +- 1.4 2

33.75-56.25' (NE) 22.B +- 3.8 2

56.25-78.75 (ENE) 19.0 +- 5.2 2

78.75-10t.25 (E) 23.9 +

.5 3

101.25-123.75(ESE) 20.2 +- 2.8 2

123.75-146.25(SE) 23.6 +- 1.1 3

14 5.25-158.75 ( 55E )

22.9 +- 1.4 3

158.75-191.25(5) 18.B +

.5 2

19L.25-213.75(55H)

IS.B +- 2.8 3

213.75-236.25(SW) 20.0 4-.4 2

236.25-258.75(H5u) 2L.7 +- 4.5 3

250.75-281.25(H) 2l.B +- 3.4 2

28L.25-303.75(WNW) 18,7 +- 2.2 2

303.75-326.25(NH) 17.9 +- 1.9 2

326,25-348.75(NNN) 22.1 +- 5.0 2

DISTANCE (mi) FROH THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/Std,Otr.) +-5td.Dev.

B-2 19.9 +- 2.7 14 2-5 2 l. 5 +- 2. 6 15

>5 22.9 +- 3.6 6

UPNIND CONTROL DRTA 27.4 +- 2.9 3

i i

s 82

-i

'0YSTER CREEK 1

TLD-DIRECT RADIATION ENVIRONMENTAL MONITORING 1

'FOR.THE PERIOD 841214-840412 120 DAYS j

FIELD TIME-95 DAYS l

1 NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/St d. Qt r.

j (deg.)

(mi.)

+- Rdm; Tot.

+- Rdm 10.6 + ; Tot.

1 001 141

.5 14.5 +-

.4-2.2

.6 ;

2.7 002 120

.9-MISSINGORDAl1AGEDDOSIMETER 003 105 1.5 MISSING OR DAMAGED DOSIMETER 004 127 1.5 14.8 +-

.4 2.2 10.9 +-

.6 2.8

.4 ;

.6 ;

005 137 1.3 14.3 +-

.4 ;.2.1

.6 ;

2.8-10.4 +-

2.7 006 158 1.2 14.9 +-

2.2 11.0 +-

.5 ;

.6.;.

007 176 2.2 15.5 +-

2.3 11.5 +-

2.9

.4 ;;

.6 ;

008 179 1.6 14.8 +-

2.2 10.9 +-

2. -8

.6 ;;

009 159 2.8 13.6 +-

.4 ;

2.0 9.7 +--

2.6 010 187 8.4 13.9 +-

.4 2.1 10.1 +-

.6 2.7

.5 ;

.6 ;;

011 173 4.4 15.4 +-

2.3 11.4 +-

2.8 012 196 4.2 MISSINGORDAllAGEDDOSIMETER 013 198 8.6 13.8 +-

.4 -

2.1 10.0~+-

.6 ;

2.7 014 185 10.

HISSINGORDAl1AGEDDOSIMETER 015 171 10.

14.8 +-

.4 2.2 10.9 +-

.6-2.8

.4 *;

2.1

.6 ;;

016 154 8.2 13.9 +-

10.1 +-

2.7 017 126 6.3 MISSING OR DAllAGED DOSIMETER 018 220 4.6 13.9 +-

.4 ;

2.1 10.1 +--

.6 2.7-

.6 ;;

019 231 5.3 14.1 +-

.4 2.1 10.2 +-

.4 ;

2.7 020 211 1.6 13.3 +-

2.0 9.5 +-

.6 2.6 022 258 1.5 13.6 +-

.4 ;

.6 ;

2.0 9.7 +-

. 4 ;;

2.6 2.2 10.8 +-

.6 ;

023 271 1.2 14.7 +-

2.8

.6 ;;

024 297 1.3 15.3 +-

.5 ;

2.3 11.4 +-

2.8 025 318 1.5 15.0 +-

.5-2.3 11.1 +-

.6 ;

2.8 026 341 3.2 MISSINGORDAllAGEDDOSIMETER 027 330 4.6 15.6 +-

.5 2.3 11.6 +-

.6 2.9

.4 ;;

.6 ;;

028 358 3.2 14.5 +-

2.2 10.6 +-

2.7 029 4

1.8 14.4 +-

.4' 2.2 10.5 +-

.6 ;

2.7 030 19

.8 MISSINGORDAllAGEDDOSIMETER 031 69 1.4 14.2 +-

.4-2.1 10.3 +-

.6 ;

2.7 032 78 2.5 MISSINGORDAllAGEDDOSIMETER 033 85 2.2 13.3 +-

.4 2.0 9.5 +-

.6 ;

2.6

.4 ;

034 38 1.7 14.3 +-

2.1 10.4 +-

.6 ;

2.7

.5 ;

035 24 1.9 15.7 +-

2.4 11.8 +-

.6 ;

2.9 036 50 3

MISSINGORDAllAGEDDOSIMETER 037 46 4.8 MISSING OR DAMAGED DOSIMEiER 038 27 4

14.8 +-

.4 2.2 10.9 +-

.6 ;

2.8

.4 ;;

039 12 8.9 14.6 +-

2.2 10.7 +-

.6 2.8

.6 ;

040 10 8.7 14.7 +-

.4 2.2 10.8 +-

2.8

.4 ;'

.6 ;;

041 3

9.9 14.6 +-

2.2 10.7 +-

2.8 042 38 10.

MISSINGORDAllAGEDDOSIMETER 043 46 9.1 17.2 +-

.5 2.6 13.2 +-

.6 ;

3.0

.4 ;;

044 73 6.5 13.9 +-

2.1 10.1 +-

.6 2.7

.6 ;

045 79 6

14.7 +-

.4 2.2 10.8 +-

2.8

.5 ;

.6 ;;

046 278 20.

15.3 +-

2.3 11.4 +-

2.8

.5 ;;

047 278 20.

15.5 +-

2.3 11.6 +-

.6 ;

2.9 TRANSIT DOSE =

3.3

+-

.4 ; 1.9

l

-l 83 OYSTER? CREEK FOR-THE PERIOD 841214-840412 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (deg.)

NET RVER. EXPOSURE RATE 4-IN GROUP (mR/Std.Otr.) t-Std.Dev.

348.75-11.25-(N) 10.7 +

.1 4

11.25-33.75 (NNE)

It.1 +

.B 3-33.75-56.25 (NE) 11.B +- 1.9 2

i 56.25-78.75 (ENE) 10.2 +

.2 2

78.75-101.25 (E) 10.1 +

.9 2

101.25-123.75(ESE)

NO DATR+-NO DATR~

'8 123.75-146.25(SE) 10.E +

2 3

i 145.25-158.75(55E)

-10.2 +

.5 3

150.75-191.25(5) ll.B +

.5

.5 19t.25-2L3.75(55N) 9.7 4-

.3 2

213.75-236.25(SN) 10.1 +

.1

-2 236.25-258.75(WSW) 9.7 +- E.9 1

258.75-201.25(W) 10.8 +- 3.0 1

281.25-303.75(WNW) 11.4 +- B.O 1

303.75-326.25(NN) 11.1 +- E.O 1

326.25-348.75(NNN) 11.E +- B.O 1

4 1

DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/5td,Otr.)

+-5t d. De v,

B-2 10.7 +

.E 14 2-5 10.7 +

.B 8

l

>5 10.7 +

.9 11 UPNIND CONTROL DATR IL.5 +-.1 2

L l

84 PALISADES TLD DIRECT RADI ATION EN'v'IRONMENTAL MONITORING FOR THE PERIOD 831212-840420 130 DAYS FIELD TIME 93 DAYS NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0t r.

(dea.)

(mi.)

+- Rdm; Tot.

+- Rdm; Tcit.

001 195 4.9 MISSING OR DAMAGED DOSINETER 002 173 4.6 18.2 +-

.5 ;

2.7 NO NET DflTA

.6 2.9 N0 llET DflTA 003 156 3.9 19.0 +-

.6 ;

2.8 N0 NET DflTA 004 132 4.6 18.6 +-

.6 ;

2.9 N0 NET DflTA 005 118 3.3 19.3 +-

.5 ;

2.7 fl0 flET DflTA 006 152-1.8 18.1 +-

.5 ;

2.7 N0 NET DfiTA 007 196 2.2 17.8 +-

.6 ;

2.8 NO NET DflTA 008 178 1.6 18.7 +-

.5 ;

2.7 NO NET Df!TA 009 200 0.9 18.1 +-

.6 ;

2.8 N0 NET DflTA 010 124 1.8 18.5 +-

.6 ;

3.0 NO NET DflTA 011 107 1.6 19.8 +-

.6 ;

2.8 NO NET DflTA -

012 90 1.5 18.7 +-

.6 ;

2.8 II0 NET DflTA 013 65 1.7 18.9 +-

.6 ;

2.8 N0 tlET DfiTA 014 51 1.9 19.0 +-

015 74 3.7 MISSINGORDAllAGED-DOSIMETER 016 90 3.6 19.4 +-

.6 ;

2.8 NO NET DflTA 017 98/

10.

19.3 +-

.6 ;

2.9 NO -NET DflTA 018 47 4.5 21.0 +-

.6 ;

3.1 t10 flET DftTA 019 23 1.5 18.8 +-

.6' 2.8 N0 llET DflTA 020 32 4.8 MISSIllGORDAllAGEDDOSIMETER 021 29 7.0 19.8 +-

.6 ;

3.0 NO NET DflTA 022 99/

15.

19.8 +-

.6 ;

3.0 NO NET DfiTA 023 98/

18.

19.4 +-

.6 ;

2.9 N0 NET DfiTA 024 98/

18.

19.8 +-

.6 3.0 110 NET DflTA NO TRANSIT DOSE CALCULATED (TuD CONTROLS; MISSING OR OTHERWISE NOT CO

-b

~85

- ~ PALISADES-

-.FOR THE PERIOD 831212-840420 TLD-DIRECT RADI ATION ENVIROHf1 ENTAL 110NITORING RZIMUTH (de's. J'.

. -RVER. EXPOSURE. RATE

.* IN GROUP

' ( mR/St d. 0t r. ) - t-S t d. De v.

348.75-!L.25 (N)

NO DRTR+-NO DATR 0

-11.25-33.75 (NNE).

13.4 +

.5 2-33.75-56.25 (NE) 13.8 +- 1.0 2

56.25-78.75 (ENE)

-13.1-+- B.O 1

78.75-101.25 (E) 13.0 +

.3 3

10l.25-123.75(ESE) 13.5 +

.2 2

123.75-148.25(SE) 12.B +-.B 2

14 5.25-159.75 ( 55E )

12.8 +

.5 2

158.75-191.25(5) 12.B +--.3

-2 19t.25-213.75(55N) 12.4 4

.1 2

213.75-236.25(SW)

NO DATA &-NO DATR

-0 236.25-258.75(WSW)

No DRTRt-NO DATH 2

258.75-281.25(W)

No DRTRt-NO DATR G

281.25-303.75(HNH)

No DRTRt-N0 DATR 0

303.75-326.25(NN)

NO DRTRt-NO DATR S

326.25-348.75(NNH)

No DRTR+-NO DATR 0

DISTANCE (mt) FROM THE REACTOR RVER. EXPOSURE RATE 4 IN GROUP (mR/5td Qtr.) +-5td.Cev.

B-2 13.9 +

.3 9

2-5 13.1 +

.7 7

>5 13.5 +

.3 2

UPNIND CONTROL DRTA 13.B +

.2 3

86 PALO VERDE-

-TLD DIRECT RADIATION ENVIRONMENTAL HONITORING

-FOR-THE PERIOD 831208-840411.125 DAYS FIELD TIME 93 DAYS NRC^

LOCATION GROSS NET EXPOSURE RATE-.

STATION AZINUTH/DIST EXPOSURE (mR)'

mR/Std.0tr.

(dea.)

(mi.)

25.5 +; Tot.

22.4 + ; Tot.

+- Rdm

+- Rdm 001 74 23,

.8 3.8

.9-4.2

.8 ;;

.8 ;

002 92

21. -

25.3 +-

3.8 22.2 +-

4.1

.7 3.6 20.8 +-

.8 ;

003 89 15.

23.8 +-

3.9

.7 ;~ 3.7

.8 ;

-004 103 11.

24.4 +-

21.4 +-

4.0

.8 ;

4.0 23.'9 +-

.9 ;

005-140

.7. 4 27.0 +--

4.4

.8 ;

.9 ;;

006 142 3.1 25.5 +-

3.8 22.4 + -

4.2

.8 ;;

007 162 2.6 26.5 +-

4.0 23.4 +-

.9 4.3

.8-;;

4.1

.j 008 168 2.6 25.0 +-

.8 3.8 22.0 +-

009 193 2.6 26.7 +-

.8 ;

4.0 23.6 +-

.9

4. 3 '

.8 ;

.9 ;;

010 215 3.1 27.0 +-

4.1 23.9 + '

4.4

.8 ;;

3.9 011 200 1.7 26.3 +-

23.2 +--

.9 ;

4.3 012 214 1.0 25.3.+-

.8 3.8 22.2 +-

.8 4.1

.8 ;

. 9. ;

013 242-0.7 27.7 +-

4.1 24.6 +-

4.4

.8 ;

4.0 23.6 +-.9; 014 263 0.6 26.7 +-

4.3 015 295 0.6 25.6 +-

.8 ;

.9 ;

3.8 22.5 +-

4.2

.8 ;;

.9 ;;

016 325 1.0 26.4 +-

4.0 23.3 +-

.4. 3 017 347 1.8 27.2 +-

.8 ;

4.1 24.1 +-

.9' 4.4

.9 ;;

018 0

2.4 27.3 +-

.8 4.1 24.2 +-

4. 4 ~

019 18 1.5 24.9 + -

.7 ;

3.7 21.8 +-

.8 ;

4.1 020 37 2.0 25.5 +-

.8 ;

3.8 22.4 +-

.9 ;

4.2 021 58 2.3 27.5 +-

.8 ;

4.1 24.4 +-

.9 4.4 022 75 2.8 27.0 +-

.8 ;

.9 ;

4.0 23.9 +-

4.4

.8-;;

.8 ;;

023 93 4.4

-25.1 +-

3.8 22.0 +-

4.1 024 101 3.3 25.7 +-

.8 ;

3.9 22.7 +-

.9 4.2 025 346 2.9 25.5 +-

.8 ;

3.8-22.4 +-

.9 ;

4.2-026 334 4.3 28.5 +-

.9 ;

4.3 25.4 +-.9; 4.6

.9 4.3 25.3 +-

.9 ;

027 333 7.9 28.5 +-

4.6

.8 ;;

.9 ;;

028 0

7.0 27.7 +-

4.2 24.6 +-

4.5 029 9

4.2 27.4 +-

.8 ;

4.1 24.3 +-

.9 ;

4.4 030 27 3.6 26.9 +-

.8 ;

4.0 23.8 +-

.9 ;

4.3 031 49 3.5 27.8 +-

.8 4.2 24.6 +-

.9 ;

4.5 032 120 3.3 29.0 +-

.9 ;;

4.3 25.8 +-

.9 ;

4.6 TRANSIT DOSE = 2.3

+-

.4 ; 2.0 1

l l

87 PALO VERDE FOR THE PERIOD 831208-840411 TLD DIRECT RADIATION ENVIRONMENTAL NONITORING RZIMUTH (deg.)

NET AVER. EXPOSURE RATE

$_.IN GROUP

-(mR/Std.Qtr.) t-Std.Dav.

348.75-11.25 (N)-

24.4 +

.2 3

11.25-33.75.(NNE) 22.8 +- 1.4 2

l 33.75-56.25 (NE) 23.5 +- 1.6 2

56.25-78.75 (ENE) 24.1 +

.3 2

78.75-10l.25 (E) 22.3 +

.4 2

10l.25-123.75(ESE) 23.6 +- 3.1 2.

123.75-148.25(SE) 23.1 +- 1.0 2

145.25-150.75(55E) 22.7 +- 1.0 2

158.75-191.25 t 5)

NO DRTR4--NO DRTR 8

ISL.25-213.75(55H) 23.4 4-

.3 2

213.75-236.25 ( SW )

23.1 4-1.2 2

236.25-258.75(W5W) 24.6 +- 2.0 1

258.75-281.25(W) 23.6 +- E.O 1

281.25-303.75(WNW) 22.5 +- 2.0 1

303.75-326.25(NH) 23.3 +- B.O 1

326.25-348.75(NNN) 24.3 +- 1.4 4

DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/5td,Qtr.)

+-St d. De v.

B-2 23.1 +

.9 9

l 2-5 23.7 +- 1.1 16 l

>5 23.9 +- 1.7 4

UPHIND CONTROL DRTA 2l.B +

.9 3

l i

't 88 PEACH BOTTOM TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR-THE PERIOD 831212-840411 121 DAYS FIELD TIME 103 DAYS HRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST-EXPOSURE (mR):

mR/Std.Qtr.

(deg.)

(mi.')

+- Rda; Tot.

14.5 + ; Tot.

+- Rdm 001 329 10.

18.8 +-

.6 ;

2.8

.6 ;' 2.9 002 31 10.

21.4 + -

.7 ;

3.2

.7 ;

.6 16.8 +-

.7 3.2:

003 22 4.7 22.9 +.

3.4 18.1 +-

3.4

.6 ;

.7 ;; - 3.2

004, 4

5 20.9 +-

3.1 16.3 +-

.6 ;

005 345 4.1 20.8 + ~

3.1 16.3 +-

.7 3.2-

.7 ;;

.7 ; '3.3 006 9

2.2 22.3 +-

3.3-17.6 +-

.7 ;

007 22 2.5 22.3 +-

.7 ;

3.3 17.5 +--

3.3

.7 ;

008

-55 2.9 22.0 +-

.7 ;

3.3 17.3 +-

3.3.

.7 ;

009 45 2

20.9 +-

.6 3.1 16.4 +-

.7 ; -3.2

.6 ;;

010 63 1.7 21.2 +-

3.2 16.6 +-

3.2 011 97 2

22.3 +-

.7 ;

3.3 17.5 +-

.7 3.3

.6 ;;

012 107 2.3 16.5 +--

.5 ; - 2. 5 12.5 +-

2.7

~013 72 5

18.8 +-

.6 2.8 14.5 +-

.6 ;

2.9

.6 ;

014 86 4.6 20.9 +-

3.1 16.4 +-

.7 3.2

.7 ;

.7 ;

015 110 4.3 22.1 +-

3.3 17.-4 +-

3.3

.6 ;;

.5 ;

016 130 4.7 17.9 +-

2.7 13.7 +-

2.8

.6 ;

017 158 9

19.6 +-

2.9 15.2 +-

.6 3.0

.6 ;

.6 ;

018 163 4.6 19.8 +-

.7 ;;- 3.0 15.4 +-

3.0.

.7 ;;

019 184 3.9 22.8 +-

3.4 18.0 +-

3.4 020 203 4.9 21.7 +-

.6 ;

3.2 17.0 +-

.7 ;

3.3 021 197 2.3 22.0 +-

.7 3.3 17.3 +-

.7 3.3 022 183 1.7 21.4 +-

.6 ;

.7 ;

3.2 16.8 +-

3.2

.8 ;;

.8 ;

023 190 1.8 25.9 +-

3.9 20.7 +-

3.7

.7 ;

024 222 1.8 24.3 +-

.7 ;

3.6 19.3 +-

3.6

.7 ;;

025 248 1.7 22.6 +-

.7-3.4 17.8 +-

3.4

.7 ;;

026 268 1.8 23.8 +-

3.6 18.9 +-

.7 ;

3.5 027 288 1.9 21.0 +-

.6 ;

3.2 16.5 +-

.7 3.2 028 323 1.8 19.8 +-

.6' 3.0 15.4 +-

.6 ;

3.0 029 286 3.6 MISSINGORDAllAGEDDOSIMETER 030 264 4

21.9 +-

.7 ;

3.3 17.2 +-

.7 ;

3.3 031 262 9.9 25.0 +-

.8 3.8 19.9 +-

.8 ;

3.6

.7 ;;

032 248 3.2 22.7 +-

3.4 17.9 +-

.7 3.4 033 235-9.4 16.9 +-

.5 ;

2.5 12.8 +-

.6 ;

2.7

.7 ;. 3.4 034 319 4.9 23.1 +-

.7 ;

3.5 18.3 +-

.7 ;

035 151

.7 20.6 +-

.6 ;

3.1 16.1 +-

3.1

.6 ;

036 148 16.

18.2 +-

.5 ;

2.7 14.0 +-

2.9

.6 ;;

037 148 16.

17.0 +-

.5 ;

2.5 12.9 +-

2.7 038 148 16.

17.4 +-

.5 ;

2.6 13.3 +-

. 6 ;- 2.8 TRANSIT DOSE = 2.2

+-

.4 ; 1.8 l

i f

89 PEACH BOTTOM FOR THE PERIOD 831212-840411 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dag.)

NET AVER. EXPOSURE RATE

  • IN GROUP (mR/Std.Qir.) t-Std.Dav.

348.75-1L.25 (N) 17.0 +

.9 2

11.25-33.75 (NNE) 17.5 +

.7 3

33.75-56.25 (NE) 16.8 +

.7 2

56.25-78.75 (ENE) 15.6 +- 1.5 2

78.75-101.d5 (E) 17.0 +

.8 2

101.25-123.75(ESE) 15.0 +- 3.5 2

123.75-146.25(SE) 13.7 +- D.O 1

14 5.25-168.75 ( 55 E )

15.6 +

.4 3

168.75-191.25(5) 18.5 +- 2.0 3

19L.25-213.75(55N) 17.2 4-

.2 2

213. '/5-236. 25 ( SH )

16.1 +- 4.6 2

236.25-258.75(HSLO 17.8 +

.1 2

258.75-281.25(10 18.7 +- 1.4 3

281.25-303. 75 ( H Hin 18.5 +- 2.G 1

303.75-328.25(NH) 16.B +- 2.0 2

326,25-340.75(NNN) 15.4 +- 1.2 2

DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP

=

(mR/5td.0tr.) + -St d. De v.

B-2 17.4 +- 1.8 11 2-5 18.6 +- 1.6 18

>5 15.9 +- 2.7 5

UPNIND CONTROL DATA 13.4 +

.5 3

~90 PERRY

- TLD DIRECT RADIATION ENVIRONMENTAL MONITORING

-FOR THE PERIOD 831212-840425 135 DAYS FIELD TIME 64 DAYS NRC LOCATION GROSS NET EXPOSURE RATE-STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.

(dea.)

( m i.- )

-26.3 +; Tot.

17.4 + ; Tot.

+- Rdm

+- Rdm 001 72 5.0

.8 3.9 1.5 ;

7.3

.8 ;

003-88 5.5 25.2 +-

3.8 15.8 +-

1.5 ;

7.1-

.7 ;

004 112 6.0 24.3 +-

3.6 14.5 +-

1.4 6.9

.8 ;;

1.5 ;;

7.2 005 130 4.0 25.7 +-

3.8 16.5 +-

006 155 5.0 29.0 +-

.9 ;

4.3 21.1 +-

1.6 7.7 1.5 ;

007 178 5.2 28.1 +-

.8-

-4. 2 19.8 +-

7.5 l

008 205 4.6 MISSINGORDAf1AGEDDOSIMETER 009 220 5.2 27.0 +-

.8 ;

4.0 18.3 + - 1.5 ;

7.4 010 225 7.4 27.4 +-

.8 4.1 18.8 +-

1.5 ;

7.4

.9 ;

011 240 5.8 29.4 +-

4.4 21.7 +-

1.6 7.8

.8 ;

4.0 17.5 +-

1.5 ;

012 225 19.

26.4 +-

7.3

.8 ;

1.5 ;

013 225 19, 27.2 +-

4.1 18.6 +-

7.4

.9 ;

1.6 ;

014 212 12.

29.7 +-

4.4 22.1 +-

7.8 015 248 1.4 27.0 +-

.8 ;

1.5 ;

4.1 18.4 +-

7.4

.8 ;

1.5 ;

016 225 0.8 27.0 +-

4.1 18.4 +-

7.4

.8 ;

1.5 ;;

017 205 0.7 25.7 +.

3.8 16.5 +-

7.2 018 180 0.8 MISSINGORDAllAGEDDOSIMETER 019 152 1.8 25.3 +-

.8 ;

3.8 16.0 +-

1.5 ;

7.1 020 123 1.6 25.5 +-

.8 ;

3.8 16.2 +-

1.5 7.1 16.5 +

1.5 ;

021 105 1.4 25.7 +-

.8 ;

3.9 7.2 17.9 +-- 1.5 ;

022 85 1.2 26.7 +-

.8 -

4.0 7.3 023 65 1.4 HISSINGORDAllAGEDDOSIMETER 024 40 0.6 26.2 +-

.8 ;

3.9 17.2 +-

1.5 ;

7.2 025 40 0.6 27.2 +-

.8 ;

4.1 18.6 +-

1.5 ;

7.4 026 182 2.8 26.0 +-

.8 ;

3.9 16.9 +-

1.5 ;

7.- 2 027 175 2.8 24.5 +-

.7 ;

3.7 14.8 +-

1.4';

7.0 TRANSIT DOSE =

13.9

+-

.7 ; 3.3 f

k2

91 PERRY FOR THE PERIOD 831212-840425 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dog. )

NET AYER. EXPOSURE RATE 4 IN GROUP (mR/Std.01r.) t-Std.Dev.

348.75-11.25 (N)

NO DRTA+-NO DATR 0

11.25-33.75 (NNE)

NO DRTA+-NO DATR 0

33.75-56.25 (NE) 17.9 +- 1.0 2

56.25-78.75 (ENE) 17.4 +- B.O 1

78.75-!OL.25 (E) 16.8 +- 1.5 2

101.25-123.75(ESE) 15.7 +- 1.1 3

123.75-146.25(SE) 16.5 +- B.O 1

14 5.25-158.75 ( 55E )

18.5 +- 3.5 2

158.75-191.25(5) 17.2 +- 2.5 3

191.25-213.75 ( 55N )

15.5 +- B.O 1

213.75-236.25(SW) 10.5 +

.3 3

236.25-258.75(WSW) 20.B +- 2.4 2

258 75-281.25(W)

NO DRTAt-NO DATR 9

28L.25-303.75(WNW)

NO DATAt-NO DATR E

303.75-328.25(NH)

NO DRTAt-NO DATR 9

326.25-348.75(NNN)

NO DATA +-NO DATR 0

I f

DISTRNCE(mt) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/5td Qtr.) +-5t d. De v.

B-2 17.3 +- 1.0 9

j 2-5 17.3 +- 2.3 5

(

>5 18.2 +- 2.7 6

UPHIND CONTROL DATA 19.4 +- 2.4 3

l

92 PILGRIM TLD DIRECT RADIATION ENVIRONMENTAL MONITORING

-FOR THE PERIOD 831216-840417 123 DAYS FIELD. TIME 96 DAYS NRC LOCATION GROSS NET EXPOSURE P, ATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.

(dea.)

(mi.)

+- Rdm; Tot.

55.4 + ; Tot.

+- Rdm 001 288

.1 65.0 +-

1,9 ;

9.7 2.0 ;

9.6 002 310

.2 28.8 +-

.9 ;

4.3 21.5 +-

1.1 ;

5.0-005 289

.7 27.7 +-

.8 ;

4.2 20.5 +-

1.0 ;

4.9 006 261 1.7 24.0 +-

.7 ;

3.6 17.0 +-

1.0 ;

4.5 1.1 -

5.2 007 270

.5' 30.0 +-

.9 ;

4.5 22.6 +-

1.0 ;

4.7 008 247

.3 25.3 +-

.8 ;

3.8 18.2 +--

1.0 ;

4. 7-009 224

.3 25.9 +-

.8 ;

3.9 18.8 +-

1.0 ;

4.7

?

010 205

.3 26.1 +-

.8 ;

3.9 18.9 +-

1.1 ;

5.0 011 184 0.3 28.2 +-

.8 ;

4.2 20.9 +-

1.0 ;

4.8 012 159

.4 26.5 +-

.8 ;

4.0 19.4 +-

.9 ;

4.3 013 146

.7 22.2 +-

.7 ;

3.3 15.3 +-

1.0 ;

.7 3.6 17.0 +-

4.5 014 155 1

24.0 +-

.7 ;*

.9 ;

3.3 15.2 +-

4.3 016 136 1.3 22.1 +-

018 212

.8 HISSINGORDRE1AGEDDOSIMETER 019 232 1

21.2 +-

.6 ;

3.2 14.4 +-

.9 ;

4.2

.9 3.9 021 256 1.6 17.6 +-

.5 ;

2.6 11.0 +-

1.0 ;

4.6 022 130 2.5 24.7 +-

.7 ;

3.7 17.6 +-

.9 ;

023 146 3.4 22.2 +-

.7 ;

3.3 15.3 +-

4.3 1.0 ;

025 168 1.5 24.3 +-

.7 3.6 17.3 +-

4.6

.7 ;

.9 ;

026 180 1.3 22.4 +-

3.4 15.5 +-

4.4

.7 ;;

1.0 ;

027 231 1.8 23.6 +-

4.5 3.5 16.6 +-

1.0 ;

030 153 2.9 05.4 +-

.8 ;

3.8 18.3 +-

4.7

.9 ;

031-179 2.5 22.0 +-

.7 ;

3.3 15.1 +-

4.3

.9 ;

032 217 2.6 22.6 +-

.7 ;

3.4 15.7 +-

4.4

.9 ;

033 234 2.5 22.5 +-

.7 3.4 15.6 +-

4.4

.7 ;

037 264 4.2 24.7 +-

3.7 17.7 +-

1.0 ;

4.6

.7 ;

038 152 3.5 22.5 +-

3.4 15.6 +-

.9 ;

4.4

.6 ;

039 155 5.3 21.1 +-

3.2 14.3 +-

.9 4.2

.7 ;;

1.0 ;

040 272 4.6 24.7 +-

3.7 17.6 +-

4.6 1.0 ;;

042 281 4.6 22.8 +-

.7 ;

3.4 15.9 +-

4.4 043 291 5.8 25.3 +-

.8 ;

3.8 18.2 +-

1.0 ;

4.7 047 301 26.

24.7 +-

.7 ;

3.7 17.6 +-

1.0 ;

4.6 048 301 26.

23.6 +-

.7 3.5 16.6 +-

1.0 ;

4.5

.7 ;

049 301 26.

23.0 +-

3.5 16.1 +-

1.0 ;

4.4 TRANSIT DOSE =

5.8

+-

.8 ; 3.2 COMMENTS:

STATION 1 IS ON LICENSEE PROPERTY (PILGRIM OVERLOOK AREA).

RCCEBB IB CONTROLLED

r 93 PILGRIM FOR.THE PERIOD 831216-840417 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING-RZU1UTH (dog.)

NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dav.

348.75-11.25 (N)

No DATA +-NO DATR 0

11.25-33.75 (NNE)

NO DRTR+-NO DATR 0

33.75-56.25 (NE)

NO DRTA+-NO DATR 0

56.25-78.75 (ENE)

NO BRTA+-NO DATR 0

78.75-101.25 (E)

NO DATA +-NO DATR 0

-101.25-123.75(ESE)

NO DRTR+-NO DATR 0

123,75-146.25(SE) 15.9 +- 1.2 4

14 5.25-158.75 ( 55 E )

17.B +- 1.8 6

168.75-191.25(5) 17.2 +- 3.3 3

19L.25-213.75(55N) 18.9 +- B.0 1

213.75-236.25(SW) 16.2 +- 1.6 5

236.25-258.75tW5W) 14.B +- 5.1 2

258.75-281.25(W) 18.2 +- 2.6 5

281.25-303.75(WNH) 31.4 +- 29.8 3

303.75-326.25(NN) 2l.5 +- B.O 1

326.25-348.75(NNN)

NO DRTA+-HO DATR 0

s DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/Std. Qtr. ) + -5t d. De v.

B-2 19.8 +- 9.3 1B 2-5 16.4 +- 1.2 1B

>5 16.3 +- 2.8 2

UPHIND CONTROL ORTA 16.B +

.B 3

94 PRAIRIE ISLAND TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831212-840412 122 DAYS FIELD TIME 88 DAYS NRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/St d.Qt r.

(deg.)

(mi.)

+- Rdm; Tot.

+- Rdm 13.8 + ; Tot.

001 312-17.

19.7 +-

.6 ;

2.9

.8 ;

3.8 002 310 15.

19.8 +-

.6 3.0 13.9 +-

.8 ;

3.8

.6 ;

003 310 15.

19.2 +-

2.9 13.2 +-

.8 ;

3.7

.6 ;

004 308 5.5 20.6 +-

3.1 14.7 +-

.8 ;

3.9

.5 ;

005 297 4.1 18.3 +-

2.7 12.4 +-

.8 ;

3.6

.6 ;;

006 287 1.3 19.2 +-

2.9 13.2 +-

.8 ;

3.7 007 313 0.8 18.3 +-

.5 ;

2.7 12.3 +-

.8 ;

3.6 008 244

'0.5 19.4 +-

.6 2.9 13.4 +-

.8 ; '3.8

.6 ;

009 194 0.6 20.0 +-

3.0 14.1 +-

.8 3.8

.6 ;

.8 ;

010 155 0.5 19.8 +--

3.0 13.9 +-

3.8

.6 ;

.8 ;

011 129 1.6 18.5 +-

2.8 12.6 +-

3.7

.6 ;

.8 ;

012 153 1.4 19.5 +-

2.9 13.6 +-

3.8

.6 ;

.8 ;;

013 217 0.6 19.6 +-

2.9 13.7'+-

3.8

.6 ;

014 178 0.8 19.3 +-

2.9 13.4 +-

.8 ;

3.7

.6 ;

015 272 1.9 18.5 +-

2.8 12.5 +-

.8 ;

3.6 016 262 4.6 18.6 +-

.6 ;

2.8 12.7 +-

.8 ;

3.7

.6 ;

017 250 4.3 20.0 +-

3.0 14.1 +-

.8 3.8

.6 ;;

.8 ;;

018 225 4.1 19.0 +-

2.9 13.1 +-

3.7 019' 233 6.7 18.5 +-

.- 6 ;

2.8 12.5 +-

.8 ;

3.6 020 200 4.9 20.6 +-

.6 ;

3.1 14.7 +-

.8 ;

3.9 1

021 187 4.7 20.0 +-

.6 3.0 14.1 +-

.8 ;

3.8 022 160 4.4 19.9 +-

.6 ;

3.0 14.0 +-

.8 ;

3.8

.6 ;

023 140 4.7 21.3 +-

3. '2 15.4 +-

.8 ;

4.0

.6 ;;

024 131 6.6 19.7 +-

2.9 13.8 +-

.8 3.8

.8 ;

025 117 4.9 19.4 +-

.6 ;

2.9 13.4 +-

3.8

.8 ;

026 88 1.9 20.9 +-

.6 3.1 15.0 +-

3.9

.6 ;;

.8 ;

027 69 1.8 18.7 +-

2.8 12.8 +-

3.7

.8 ;

028 47 1.6 20.4 +-

.6 ;

3.1 14.5 +-

3.9

.8 ;

029 19 1.5 18.9 +-

.6 ;

2.8 13.0 +-

3.7

.8 ;

030 356 1.9 19.7 +-

.6 ;

3.0 13.8 +-

3.8

.8 ;

031 346 2.4 18.7 +-

.6 2.8 12.7 +-

3.7 1.4 ;

1.5 ;

032 340 3.8 47.4 +-

7.1 42.1 +-

7.6

.6 ;

.8 ;;

033 8

4.6 21.0 +-

3.1 15.1 +-

4.0

.5 ;;

034 17 4.7 18.0 +-

2.7 12.0 +-

.8 ;

3.6 035 45 11.

19.6 +-

.6 ;

2.9 13.6 +-

.8 ;

3.8 036 48 4.7 21.1 +-

.6 ;

3.2 15.2 +-

.8 ;

4.0 037 61 4.2 21.0 +-

.6 ;

3.2 15.1 +-

.8 ;

4.0 038 86 4.9 20.4 +-

.6 ;

3.1 14.5 +-

.8 ;

3.9 039 107 9.1 20.3 +-

.6 ;

3.0 14.4 +-

.8 ;

3.9 x

7 040 til 3.7 19.5 +-

.6 ;

2.9 13.5 +-

.8 ;

3.8 TRANSIT DOSE =

6.2

+-

.5 ; 2.2 l

L

95 PRAIRIE ISLAND LFOR THE PERIOD 831212-840412 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dag.)

NET RVER.. EXPOSURE RATE

$ IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-!!.25 (N) 14.4 +

.8 2

11.25-33.75 (NNE) 12.5 +

.7 2

33.75-56.25 (NE) 14.5 +

.B 3

56.25-78.75 (ENE) 14.8 +- 1.7 2

78.75-101.25 (E) 14.B +

.4 2

101.25-123.75(ESE) 13.B +

.5 3

123.75-146.25(SE) 13.9 +- 1.4 3

14 5.25-158. 75 ( 55E )

13.B 4-.2 3

158.75-191.25(5) 13.8 +

.5 2

191.25-2(3.75(55H) 14.1 +

.1 2

213.75-236.25(SW) 13.1 4-.6 3

238.25-258.75(WSW) 13.8 +

.4 2

258.75-201.25(LD

12. B +

.1 2

28l.25-303.75(WNW) 12.B +

.B 2

303.75-328.25(NN) 13.5 +- 1.7 2

326.25-348.75(NNN) 27.4 +- 28.8 2

DISTRNCE(mt) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/3td,Gtr.)

+-5t d. De v.

B-2 13.5 +

.8 15 2-5 15.5 +- B.9 17

>5 13.B +

.B 5

UPHIND CONTROL DRTA 13.B +

.3 3

96 QUAD CITIES

-TLD DIRECT RADIATION ENVIRONMENTAL MONITORING' FOR THE PERIOD 831209-840406 119. DAYS FIELD TIME 86 DAYS NRC LOCATION GROSS tlET EXPOSURE RATE STATION AZIMUTH /DIST.

EXPOSURE (mR) mR/Std.0tr.

(dea'. )

(mi.)

+- Rdm; Tot.

+- Rdm Tot.

NO NET;DflTA 001 7

O.7 17.~0 +-

.5 ; '2.5 002

'17 1.2 20.3 +-

.6 3.0 NO NET DflTA

.5 ;;

003 45 1.7 16.3 +-

2.4

'N0 t4ET Df!TA -

~004 65 1.1-17.6 +-

.5 2.6

. NO NET DfiTA

.5.;

005-90 0.8 17.2 +-

2.6 NO NET DffTA

.5 ;;

006' 136 1.1 18.0 +-

2.7 NO NET DflTA 007 175 1.8 18.2 +-

.5 2.7 NO NET DflTA

.5 ;

008 157 2.0 17.6 +-

+

2.6 N0 NET DflTA

.5 ;;

009 186 3.1

~18.0 +-

2.7 NO NET DflTA 010 188 7.7 19.3 +-

.6 2.9 NO NET DfiTA

.5 ;;

011 156 4.2 17.2 +-

2.6 N0 t1ET DflTA 012 142 4.8-17.3 +-

.5 2.6 NO NET DflTA 013 121 3.3 18.1 +-

.5 ;

2.7 NO NET DATA

.5 ;;

014 114 2.0 15.6 +-

2.3 NO NET DflTA 015 86 2.8 18.0 +-

.6 ;; -2.7

.5 NO NET DATA i

016 62 4.4 19.7 +-

2.9 NO NET DATA 017 48 6.1 18.0 +-

.5 ;

2.7 NO NET DflTA 4

018 39 8.8 18.6 +-

.6 ;

2.8

'l10 NET DfiTA 019 36 4.7

-17.7 +-

.5 ;

2.6 NO NET DATA 020 16 4.3 17.9 +-

.5 2.7 NO NET DfiTA

.5 ;;

021 358 4.2 18.1 +-

2.7 N0 NET DATA 022 336 4.1 20.4 +-

.6 ;

3.1 NO NET-DflTA 023 337 5.7 18.0 +-

.5' 2.7 NO NET Df!TA 024 317 4.4 MISSINGORDAf!AGEDDOSIMETER 025 295 4.1 17.9 +-

.5 ;

2.7 NO NET DATA 026 282 6.9 16.1 +-

.5-2.4 NO NET DflTA 027 265 4.3 MISSINGORDAllAGEDDOSIMETER 028 253 4.0 MISSING OR DAMAGED DOSIMETER 029 356 2.8 17.6 +-

.5 2.6 N0 HET DflTA

.6 ;;

.030 335 1.9 19.3 +-

2.9 N0 f1ET DflTA 031 317 2.6 19.1 +-

.6' 2.9 N0 NET DATA 032 295 2.5 MISSINGORDAllAGEDDOSIMETER 033 266 2.0 17.1 +-

.5 2.6 NO NET DATA' 034 248 2.2 17.1 +-

.5 ;

2.6 NO NET DflTA

.5 ;;

035 229 2.6 17.4 +-

2.6 NO NET DflTA 036 204 3.4 17.8 +-

.5 ;

2.7 N0 NET DflTA 037 194 8.3 18.7 +-

.6 2.8 N0 NET DflTA

.6 ;

038 224 4.6 18.6 +-

2.8 N0 flET DATA

.5 ;

039 301 15.

17.3 +-

2.6 NO NET DATA

.5 ;;

040 301 15.

17.2.+-

2.6 NO NET DfITA 041 301 15, 16.9 +-

.5 2.5 N0 !lET DffTA NO TRANSIT DOSE CALCULATED (TLD CONTROLS; HISSING OR OTHERNISE NOT l

l l

I

97 QUAD CITIES FOR THE PERIOD 831209-840406 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (deg. )

AVER. EXPOSURE RATE 4 IN' GROUP (mR/Std.Qtr.) t-Std.Dav.

348.75-11.25 (N) 13.3 +

.4 3

11.25-33.75 (NNE) 14.4 +- 1.3 2

33.75-56.25 (NE) 13.3 +

.7 4

56.25-78.75 (ENE) 14.1 +- 1.1 2

78.75-10L.25 (E) 13.3 +

.4 2

101.25-123.75(ESE) 12.7 +- 1.3 2

123.75-146.25(SE) 13.3 +

.3 2

14 5.25-158.75 ( 55E )

13.1 4-.2 2

158.75-191.25(5) 14.B 4

.5 3

19L.25-Cl3.75(55N) 13.B 4

.5 2

213.75-236.25(SW) 13.6 +

.6 2

236.25-258.75(WSW) 12.9 +- B.O 1

258.75-281.25(W) 12.9 +- B.O 1

281.25-303.75(HNH) 12.8 +

.9 2

303.75-326.25(NH) 14.4 +- 9.0 1

326.35-348.75(NNN) 14.5 +

.9 3

OISTANCE(mi) FROM THE REACTOR RVER. EXPOSURE RATE

+ IN GROUP (mR/5td,0tr.)

+-5t d. De v.

B-2 13.3 +- 1.0 11 2-5 13.7 +

.7 17

>5 13.7 +

.B 6

UPHINO CONTROL ORTA 13.0 +

.2 3

r; i

98

-RANCHO SECO TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR.THE PERIOD 831208-840504 148 DAYS FIELD TIME 89 DAYS NRC LOCATI0ft GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.

(deg.)

(mi.)

22.8 +; Tot.

16. 0 - + ; Tcit.

+- Rdm

+- Rdm 001 288 16,

.7 ;

3.4

.9 ;

4.2 002 239 12.

23.2 +-

.7 3.5 16.4 +-

.9 4.2

.8 ;

3.9 19.6 +-

1.0 ;;

003 213 16.

26.3 +-

4.6

.3 ;

004 149 9.9 25.1 +-

3.8 18.3 +-

.9 4.5

.8 ;

1.0 ;

005 108 8.2 27.1 +-

4.1 20.3 +-

4.7

.6 ;;

.8 ;;

006 86 10.

20.8 +-

3.1 14.0 +-

3.9 007 83 9.7 19.6 +-

.6 ;

2.9 12.8 +-

.8 ;

3.'8

.8 008 37 7.1 20.0 +-

.6 ;

3.0 13.2 +-

3.8

.8 ;;

009 65 0.8 21.3 +-

4.0

.6 3.2 14.5 +-

.6 ;;

010

~43 0.7 20.3 +-

3.0 13.5 +-

.8 3.9

.8 ;

011

- 131 1.6 20.7 +-

.6 ;

3.1 13.9 +-

92 0.2 20.7 +-

.6 ;

3.1 13.9 +-

3.9

.8 ;

012 3.9

.9 ;

013 358 0.6 22.8 +-

.6 ;

.8 ; -4.2

.7 3.4 16.0 +-

014 323 0.7 21.4 +-

j 3.2 14.6 +-

4.0

.8 ;

015 151 0.7 20.5 +-

.6, 3.1 13.7 +-

3.9

.8 ;;

016 219 0.9 20.4 +-

.6 ;

3.1 13.6 +-

3.9 017 245 1.5 19.9 +-

.6 3.0 13.1 +-

.8 ;

3.8

.6 ;

018 254 2.3 19.8 +-

3.0 13.0 +-

.8 ;

3.8

.6 ;

019 323 7.0 21.0 +-

3.2 14.2 +-

.8 3.9 020 309 6.3 20.7 +-

.6 ;

.8 ;

3.1 13.9 +-

3.9

.6 ;

.8 ;

021 279 5.7 20.7 +-

3.1 13.9 +-

3.9

.7 ;

3.4 16.0 +-

.9 !

4.2 022 244 6.4 22.8 +-

.6 ;;

023 217 4.6

.20.8 +-

3.1 14.0 +-

.8 3.9 024 350 11.

21.0 +-

.6 ;

3.1 14.2 +-

.8 :;

3.9 025 318 17.

21.5 +-

.6 ;

3.2 14.7 +-

.8 l 4.0 026 311 22, 22.1 +-

.7 3.3 15.3 +-

.8 l' 4.1

.6 ;

027 306 27.

21.1 +-

3.2 14.3 +-

.8 4.0

.6j; 028 306 27.

20.7 +-

3.1 13.9 +-

.8 3.9

.9 ;

029 306 27.

22.3 +-

.7 3.3 15.5 +-

4.1 030 306 27.

21.3 +-

.6, 3.2 14.5 +-

.8 ;

g 4.0 TRANSIT DOSE =

6.9

+-

.5 ; 2.3 i

I L

99 RANCHO SEC0 FOR THE PERIOD 831208-840504 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (deg.)

NET AVER. EXPOSURE RATE

$ IN GROUP

( mR/St.d.Qt r. ) t-Std.Dav.

348.75-It.25 (N) 15.1 +- 1.3 2

11.25-33,75 (NNE)

NO DATA +-NO DATR 8

33.75-56.25 (NE) 13.3 +

.2 2

56.25-78.75 (ENE) 14.5 +- B.O 1

78.75-101.25 (E) 13.5 +

.7 3

10L.25-123.75(ESE) 20.3 +- B.O 1

123.75-146.25(SE) 13.5 +- B.O 1

1 5.25-168.75(55E) 16.B 4-3.3 2

158.75-191.25(5)

NO DRTR+-NO DRTR 8

19L.25-2(3.75(55N) 19.E 4-5.0 1

213.75-236.25 (SW )

13.B +

.3 2

236.25-258.75(W5W) 14.8 +- 1.8 4

258.75-281.25(W) 13.9 +- B.O 1

28L.25-303.75(WNW) 16.9 +- B.O 1

303.75-326,25(NH) 14.B +

.5 6

326.25-348.75(NNN)

NO DRTA&-NO DATR 8

DISTANCE (m() FR0M THE REACTOP NET RVER. EXPOSURE RRTE

+ IN GROUP

( rnR/ Std. Qt r. ) + -St d. De v,

B-2 14.1 +

.9 9

2-5 13.5 +

.7 2

>5 15.5 +- 2.2 18 UPHIND CONTROL DATA 14.5 +

.7 3

J

100 ROBINSON TLD DIRECT RADIATION EiWIRONMENTAL MONITORING FOR THE PERIOD 831213-840406 115 DAYS FIELD TIME 84 DAYS HRC LOCATION GROSS HET EXPOSVRE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deo.)

(mi.)

+- Rdm; Tot.

+- Rdm 15.5 + ; Tot.

001 191 0.2 16.1 +-

.5 2.4

.6' 3.' 1

.6 ;

3.0 19.9 +-

.8 l 3.7 002 151 1.9 20.2 +-

003 134 2.0 20.4 +-

.6 ;

3.1 20.1 +-

.8

  • 3.7

.5 ;

.7 l 3.2 004 119 1.9 16.3 +-

2.4 15.8 +-

.6 005 89 2.1 19.6 +-

.6 ;

2.9 19.2 +-

3.6

.5 ;

2.6 16.7 +-

.7 ;

006 65 1.0 17.2 +-

3.3

.6 ;

2.9 19.1 +-

.7 ;

007 46 1.8 19.5 +-

3.6

.6 ;;

.7j; 008 27 1.9 19.3 +-

2.9 19.0 +-

3.6 009 22 3.5 19.1 +-

.6' 2.9 18.8 +-

.7, 3.5 010 0

5.0 MISSINGORDAbAGEDDOSIMETER 011 51 4.8 20.3 +-

.6 3.0 20.0 +-

.8 3.7

.5 ;;

.6 ;

012 67 4.1 15.4 +-

2.3 14.7 +-

3.0

.6 ;;

013 87 4.5 15.9 +-

.5' 2.4 15.3 +-

3.1 1

014 109 5.0 MISSINGORDAbAGEDD0SIMETER 015 118 4.8 17.3 +-

.5 -

2.6 16.8 +-

.7 ;

3.3 016 138 5.3 MISSINGORDAbAGEDDOSIMETER 017 115 17.

16.6 +-

.5 ;

2.5 16.1 +-

.7 ;

3.2 i

018 199 12.

17.2 +-

.5 ;

2.6 16.7 +-

.7 3.3

.6 3.2 21.1 +-

.8 ;

l' 020 225 4.0 19.7 +-

019 208 4.8 21.3 +-

3.9

.6 ;;

.7 ;;

3.0 19.4 +-

3.6 021 178 4'. 6 13.8 +-

.4 ;

2.1 13.0 +-

.6 ;

2.8 022 167 3.7 16.7 +-

.5 '

2.5 16.1 +-

.7 3.2

.5 2.5 16.2 +-

.7 ;

023 181 2.3 16.7 +-

.6 ;;

3.2

.7 ;;

024 194 2.0 20.0 +-

3.0 19.7 +-

3.7 025 228 2.1 17.7 +-

.5 2.6 17.2 +-

.7 3.3

.5 ;

.6 *;

026 245 1.5 16.2 +-

2.4 15.6 +-

3.1

.5 ;;

.6 l 2.9 027 273 1.8 15.7 +-

2.3 15.1 +-

3.1 028 287 2.0 14.4 +-

.4 2.2 13.7 +-

.6

.5 ;;

2.7 17.3 +-

.7 ;

029 311 1.6 17.7 +-

3.3 030 334 1.9 17.3 +-

.5 2.6 16.8 +-

.7 ;

i 031 353 1.8 15.9 +-

.5 ;

3.3

.7 ;l 3.4 2.4 15.3 +-

.6 3.1

.5 ;;

1 032 333 4.0 17.8 +-

2.7 17.4 +-

033 318 4.7 18.3 +-

.5 2.7 17.8 +-

.7 ;

3.4

.5 ;;

i 034 310 6.9 15.7 +-

2.4 15.1 +-

.6*

.8 l 3.1 035 295 4.0 21.0 +-

.6-3.2 20.8 +-

3.8 036 269 4.8 MISSINGORDAbAGEDDOSIMETER 037 252 4.6 18.9 +-

.6j 2.8 18.5 +-

.7 ;

3.5 i

038 274 10.

18.3 +-

.5, 2.7 17.8 +-

.7 ;

3.4 039 286 15.

15.4 +-

.5 ;

2.3 14.8 +-

.6 3.0

.6 ;;

1 040 289 16, 15.4 +-

.5 2.3 14.7 +-

3.0

.5 ;

041 291 17.

16.5 +-

2.5 16.0 +-

.7 ;

3.2 i

TRANSIT DOSE =

1.6

+-

.4 ; 1.6 4

1 L

101 ROBINSON FOR THE PERIOD 831213-840406 TLD DIRECT RADIATION ENVIRONMENTAL M0HITORING RZIMUTH (deg. )

NET RVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dev.

L 348.75-11.25 (N) 15.3 +- B.O 1

11.25-33.75 (NNE) 18.5 +

.2 2

33.75-56.25 (NE) 19.E +

.E 2

56.25-78.75 (ENE) 15.7 +- 1.4 2

78.75-101.25 (E) 17.3 +- 2.8 2

101.25-123.75(ESE) 16.2 +

.5 3

123.75-148.25(SE) 20.1 +- B.0 1

145.25-169.75(55E) 19.5 4-2.7 2

168.75-191.25(5) 14.5 4-1.7 3

19L.25-2L3.75(55N) 19.1 4-2.3 3

213.75-236.25(SW) 10.3 +- 1.6 2

236.25-258.75(W5H) 17.1 +- 2.1 2

258.75-281.25(H) 16.5 +- 2.0 2

281.25-303.75(HHH) 17.3 +- 5.0 2

303.75-326.25(NN) 16.7 +- 1.4 3

326.25-348.75(NNN) 17.1 +

.4 2

OISTANCE(mt) FROM THE REACTOR NET RVER. EXPOSURE RATE 4 IN GROUP

( mR/5td, Q t r'. ) + -Si d. De v.

B-2 17.1 +- 2.1 14 2-5 17.7 +- 2.3 15

>5 16.4 +- 1.1 4

UPHINO CONTROL ORTA 15.2 +

.7 3

102 ST.LUCIE TLD DIRECT RADIATION ENVIRONMENTAL 110NITORING FOR THE PERIOD 831213-840413 122 DAYS FIELD TIl1E 101 DAYS HRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deg.)

(mi.)

+- Rdm; Tot.

+- Rdm

11. 5 + ; Tcit.

001 20 0.3 16.7 +-

.5 2.5 002 45 0.2 19.1 +-

.6 ';

.6' 2.9 2.9 13.6 +-

.7 l 3.1 003 67 0.2 MISSINGORDAl1AGEDDOSI!1ETER 004 92 0.3 15.5 +-

.5' 2.3 10.4 +-

.6 ;

2.8

.4 ;l 2.1 005 115 0.4 14.2 +-

.4 2.1 9.3 +-

.6 2.6

.6 ;;

006 143 1.1 13.7 +-

8.8 +-

2.6 007 150 2.0 13.5 +-

.4 ;

2.0 8.6 +-

.6 2.6

.6 ;;

008 154 4.7 14.3 +-

.4 ;

2.1 9.3 +-

2.6 009 152 22, 13.4 +-

.4 2.0 8.5 +-

.5 ;;

.6 2.6

.6 ;;

010 152 22, 15.0 +-

2. 3 10.0 +-

2.7 011 152 22.

16.3 +-

.5 ;

2.4 11.1 +-

.6 2.8

.6 ;;

012 168 14.

14.6 +-

.4 ;

2.2 9.6 +-

2.7 013 185 10.

16.4 +-

.5 2.5 11.2 +-

.6*

2.8

.6 *;

2.8 13.1 +-

.7 l 3.1 014 183 11.

18.5 +-

015 170 8.0 f11SSINGORDAllAGEDDOSIf1ETER 016 196 7.0 15.7 +-

.5 ;

2.4 10.6 +-

.6 2.8

.4 2.2 9.4 +-

.6 ;

017 229 7.9 14.4 +-

018 250 6.6 14.2 +-

.4 ;

2.7 2.1 9.3 +-

.6 ;

j 019 247 4.8 15.0 +-

.4 ;

2.6 2.2 9.9 +-

.6 ;

.5 ;

2.7 2.3 10.0 +-

.6 ;

020 229 5.0 15.0 +-

021 208 3.8 14.7 +-

.4 ;

2.7 2.2 9.7 +-

.6 ;

022 187 3.8 14.0 +-

.4 ;

2.7 2.1 9.1 +-

.6 ;

2.6 023 203 2.6 14.6 +-

.4 ;

2.2 9.6 +-

.6 ;

2.7

.6 ;

024 245 1.9 14.1 +-

.4 2.1 9.1 +-

.5 ;;

2.6 2.4 10.6 +-

.6 ;

025 280 2.2 15.8 +-

2.8

.6 ;;

026 299 3.1 15.6 +-

.5 ;

2.3 10.5 +-

2.8 027 305 3.8 15.1 +-

.5 2.3 10.0 +-

.4 ;;

.6 2.7

.6 ;;

028 276 4.0 14.3 +-

2.1 9.3 +-

2.6 029 293 5.8 15.1 +-

.5 2.3 10.1 +-

030 316 7.7 15.2 +-

.5 ;

.6 2.7

.6 ;;

2.3 10.1 +-

2.7 032 300 10.

MISSING OR DAMAGED DOSIllETER 033 322 8.7 16.6 +-

.5 ;

2.5 11.4 +-

.6 2.9 034 339 8.8 15.0 +-

.5-2.3 10.0 +-

.6 ;

2.7

.5 ;! 2.1

.4 9.2 +-

.6 l 2.6 035 342 2.9 14.1 +-

036 346 1.9 16.0 +-

2.4 10.8 +-

.6 ;

2.8 037 353 1.0 14.0 +-

.4 2.1 9.1 +-

.5 ;;

.6 2.6

.6 ;;

038 226 2.0 15.7 +-

2.4 10.6 +-

2.8 TRANSIT DOSE =

3.8

+-

.5 ; 2.1

103 ST.LUCIE FOR THE PERIOD 831213-840413 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RIIMUTH (deg. )

NET AVER. EXPOSURE RATE

$ IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-11.25 (N's 9.1 +- 8.B 1

13.25-33.75 (NNE)

!!.5 +- B.O 1

i 33.75-56.25 (NE) 13.5 +- 14.0 1

56.25-78.75 (ENE)

NO DRTA+-NO DATR 8

78.75-lOL.25 (E) le.4 +- B.O 1

10L.25-123.75(ESE) 9.3 +- 8.9 1

123.75-146.25(SE) 8.8 +- 8.8 1

146.25-168.75(55E) 9.24

.5 3

168.75-191.25(5)

IL.1 4-2.0 3

151.25-2L3.75(55N) 10.8 +

.E 3

213.75-236.25(SW) 10.8 +

.E 3

236.25-258.75(WSW) 9.4 +

.4 3

258.75-201.25(W) 10.9 +

.5 2

28L,25-303.75(WNW) 10.3 +

.3 2

303.75-326.25(NN) 10.5 +

.7 3

326.25-348.75(NNN) 10.9 +

.5 3

03 STANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/Etd.Qtr.) +-5td.Dev.

B-2 10.2 +- 1.5 1B I-5 9.8 +

.5 11 35 10.5 +- 1.2 10 UPHIND CONTROL DATA 9.9 +- 1.3 3

104 SALEN TLD DIRECT RADIATION EtWIR0t1HEt1TAL MONITORING FOR THE PERIOD 831216-840408 114 DAYS FIELD TIME 91 DAYS t1RC LOCATI0t1 GROSS t1ET EXP05URE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.

(deg.)

(mi.)

+- Rdm; Tot.

+- Rdm 002 79 3.4 17.1 +-

.5

  • 2.6 12.4 + ;Tct..7 ;

3.3 003 72 3.6 HISSINGORDAl1AGEDDOSIMETER 004 58 4.2 17.9 +-

.5 2.7 13.2 +-

.7 ;

3.4 005 54 4.9 16.8 +-

.5 ;

2.5 12.0 +-

006 68 8.6 15.2 +-

.5 ;

.7 3.3

.7 *;

2.3 10.5 +-

3.1

.5 l 2.6 2.6 12.8 +-

.7 !

3.4 007 40 5.7 17.6 +-

008 116 11.

17.3 +-

.5 12.5 +-

.7

?.3 010 8

5.8 17.4 +-

.5 ;

.7 ;

2.6 12.6 +-

.5 ;;

3.3

.7 ;

011 15 8.1 16.8 +-

2.5 12.1 +-

3.3

.7 ;

012 24 8.6 15.5 +-

.5 2.3 10.8 +-

.5 ;

3.1

.7 ;

013 49 8.6 15.5 +-

2.3 10.8 +-

.5 ;

3.1

.7 ;

014 90 6.7 15.0 +-

2.3 10.3 +-

.5 ;;

3.1

.7 ;;

015 105 6.4 15.1 +-

2.3 10.3 +-

3.1 TRAtlSIT DOSE =

4.6

+-

.5 ; 2.1 COMMENTS:

THIS STATI0ti TLD EXCHRtJGC IS DIVIDED BETHEEtl THE STATES OF N.J. AND DEL. STftTION 1-16 (N.J. ). STATION 17-50 (DEL. )

l l

l

r-105 SALEM FOR THE PERIOD 831216-840408 TLD DIRECT RADIATI0il EtWIRONMENTAL MONITORING RZIMUTH (dog.7 NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std Dav.

348.75-ll.25 (N) 12.8 +- 8.0 1

13.25-33.75 (NNE) ll.4 +

.5 2

33.75-56.25 (NE) 11.9 +- 1.0 3

56.25-78.75 (ENE)

IL.B +- 1.9 2

78.75-10l.25 (E)

IL.3 +- 1.5 2

101.25-123.75(EJE)

IL.4 +- 1.5 2

123.75-146.25(SE)

NO DATA +-NO DATR 8

146.25-168.75(55E)

NO DRTR&-NO DATR 8

169.75-131.25(5)

NO DRTR&-NO DRTR 8

19L.25-2L3.75(55H)

NO DRTR&-NO DATR 8

213.75-236.25(SW)

NO DRTA&-NO DATA 8

236.25-258.75(WSW)

NO DATAt-NO DATR S

258.75-28. 25(W)

NO DRTAt-NO DATR 9

28L 25-333.75(WNW)

NO DATRt-NO DATR S

303.75-326,25(NH)

NO DATAt-N0 DATR 9

326.25-348.75(NNN)

NO DRTA+-NO DATR 8

DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RRTE 4 IN GROUP (mR/Etd.Otr.) + -51 d. De v.

B-2 NO DATAt-NO DATR G

2-5 12.5 +

.5 3

55 11.4 +- 1.1 9

UPHIND CONTROL DATA NO DATA NO DATA

106 SALEM TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831216-840408 114 DAYS FIELD TIME 91 DAYS NRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deg.)

(mi.)

+- Rdm 20.7 +; Tot.

+- Rdm Tot.

.6 3.1 N0 f1ET;DflTA 017 331 4.2 018 320 3.8 15.9 +-

.5 ;

2.4 NO NET DflTA

.5 ;

019 299 3.4 18.3 +-

2.7 fl0 flET DflTA 021 276 3.6 20.1 +-

.6 ;

3.0 110 NET DfiTA 022 266 4.7 19.8 +-

.6 ;

3.0 N0 flET DflTA 023 257 4.4 19.7 +-

.6 ;

3.0 N0 NET DflTA 024 240 4.4 20.0 +-

.6 ;

3.0 N0 NET DftTA

.6 ;;

025 217 4.9 19.8 +-

3.0 110 NET DflTA 026 204 3.9 18.2 +-

.5 2.7 N0 flET DflTA 027 188 4.2 20.0 +-

.6 ;

3.0 NO NET DflTA

.7 ;;

028 319 20 22.0 +-

3.3 N0 ilET DflTA 029 265 6.7 17.2 +-

.5 ;

2.6 N0 ilET DfiTA 030 353 12.

18.9 +-

.6 2.8 fl0 NET DflTA

.6 ;;

031 0

18 19.5 +-

2.9 HO NET DflTA 032 338 8.1 17.4 +-

.5 ;

2.6 NO NET DfiTA 033 265 9.8 19.6 +-

.6 2.9 N0 NET DflTA 034 270 13.

19.4 +-

.6 ;

2.9 N0 NET DATA NO TRANSIT DOSE CALCULATED (TLD C0HIROLS; MISSING OR OTHERWISE N COMMENTS:

THIS STATION TLD EXCHRNGE IS DIVIDED BETNEEN THE STATES OF N.J. AND DEL. STATION 1-16 (N.J. ). STATION 17-50 (DEL. )

l

107-SALEM FOR THE' PERIOD 831216-840408 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dog.)

AVER. EXPOSURE RATE

$ IN GROUP (nR/Std.0tr.) t-Std.Dav.

348.75-11.25 (N)

NO DRTR+-NO DATR 0

l 11.25-33.75 (NNE)

No DATR+-NO DATR 0

33.75-56.25 (NE)

NO DRTR+-NO DATR 0

56.25-78.75 (ENE)

NO DATR+-NO DATR 0

78.75-10l.25 (E)

NO DRTA+-NO DATR 0

101.25-123.75(ESE)

NO DRTA+-NO DATR 0

123.75-146.25(SE)

NO DATA +-NO DATR 0

14 6.25-168.75 ( 55E )

NO DRTR+-NO DRTR 8

168.75-191.25(5) 15.8 4-B.O 1

ISL.25-213.75(55H) 14.3 +- B.O 1

213.75-236.25(SW) 15.E 4-B.O 1

238.25-258.75 ( W5W )

15.7 +

.1 2

258.75-281.25(W) 15.2 +

.9 5

28l.25-303.75(WNW) 14.4 +- G.O 1

303,75-328,25(NN) 12.5 +- B.O 1

326.25-348.75(NNN) 15.0 +- 1.8 2

DISTANCE (mi) FROM THE REACTOR RVER. EXPOSURE RRTE

+ IN GROUP (mR/5td.Qtr.) +-St d. De v.

9-2 NO DRTAt-NO DATR 0

2-5 15.2 +- 1.1 10

>5 14.5 +- 1.0 4

l UPNIND CONTROL ORTA 15.9 +- 1.3 3

i I

~

1q

.108 M

SfiH ON0FRE

~'

TLD DIRECT RADIATION ENVIRONMENTflL MONITORING l

1 FOR THE PERIOD 831208-840504 148 DAYS FIELD TIME 75 DAYS j

NRC LOCflTION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.

(deg.)

(mi.)

+- Rdm; Tot.

+- Rdm Tot.

J NO NET;DflTA 001 34o 35.

28.7 +-

.9 4.3

.8 ;;

1 002 346 35.

27.0 +-

4.0 N0 NET DflTA 003 346 35.

28.7 +-

.9 4.3-NO NET DflTA

~

004 327 11.

22.7 +-

.7 ;

3.4 NO NET DflTft 005-308 14.

25.4 +-

.8 ;

3.8 HO NET DflTA

.7 ;;

-006 307 10.

23.1 +-

3.5 NO HET DflTA

-007 318 6.3

'23.8 +-

.7 3.6 NO NET DflTA 008 322-5.1 25.7 +-

.8 ;

3.8 NO NET DflTA 009 311 3.3 MISSING OR DfiNAGED DOSIMETER 010 331 3.3 25.3 +-

.8 -

3.8 NO NET DflTA 011 300 2.6 MISSINGORDAbfiGEDDOSIMETER 012 285 0.5 26.4 +-

-.8 4.0 NO NET DfiTA 013 320 2.4 23.5 +-

.7 3.5 NO NET DflTA

.7 ;;

014 320 1.7 23.4 +-

3.5 NO NET DflTA 015 333 1.2 MISSING OR DAMAGED DOSIMETER 016 30 1.9 25.9 +-

.8 ;

3.9 NO NET DflTf1 017-8 1.3 21.6 +-

.6 3.2 NO NET DflTA 019 55 2.9 24.6 +-

.7 ;

3.7 NO NET DfiTA

.8 ;;

020 77 4.1 25.2 +-

3.8 N0 NET DfiTA 021 87 4.7 25.8 +-

.8 3.9 NO NET DflTfi 022 25 3.4 28.4 +-

.9 ;

4.3 NO NET DflTA

.8 ;;

023 357 3.5 27.1 +-

4.1 NO NET DflTA 024 25 0.4 23.6 +-

.7 ;

3.5 NO HET DflTfi 025 81 0.4 23.1 +-

.7 3.5 N0 NET DflTA 026 126 2.1 23.1 +-

.7 ;

3.5 NO NET DflTfi

.7 ;;

027 130 8.6 22.2 +-

3.3

'NO NET Df;Tfi 028 99 8.9 21.6 +-

.6 3.2 NO NET DfiTA 029 135 11.

21.5 +-

.6 ;

3.2 NO NET DflTA

.6 ;;

030 126 2.0 19.1 +-

2.9 N0 flET DflTA 031 128 3.7 18.5 +-

.6 ;

2.8 N0 NET DflTA 032 140 22.

22.6 +-

.7~

3.4 NO NET DfiTfi 033 120 26.

20.9 +-

.6 ;

3.1 NO NET DflTfl NO TRfiNSIT DOSE CfiLCULfiTED (TLD CONTROLS; MISSING OR OTHERNISE r

1

109 SAN ONOFRE

-FOR THE PERIOD 831208-840504 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (deg.)

RVER.' EXPOSURE RATE.

  • IN GROUP' (mR/Std.Qir.) t-Std.Dav.

348.75-1l.25 (N) 14.8 +- 2.3 2

11.25-33.75 (NNE) 15.B +- 1.5 3

33.75-56.25 (NE) 15.0 +- B.O.

1 56.25-78.75 (ENE) 15.3 +- B.O 1

i 78.75-101.25 (E) 14.3 +- 1.3 3

101.25-123.75(E5E) 12.7 +- B.O 1

123.75-148.25(SE) 12.9 +- 1.2 6

14 5.25-158. 75 ( 55 E )

NO DRTR&-NO DRTR 8

158.75-191.25(5)

NO DRTR+-NO DRTR B

191.25-213.75(55N)

NO DRTR+-NO DRTR 8

213.75-236.25(SW)

NO DATA +-N0 DATA 0

238.25-258.75(WSW)

NO DRTAt-NO DATR 0

258.75-281.25(W)

NO DRTAt-NO DATR E

281.25-303.75(WNH) 18.1 +- B.O 1

303.75-328.25(NN) 14.7 +

.7 8

326.25-348.75(NNN) 14.6 +- 1.1 2

DISTANCE (mi) FROM THE REACTOR RVER. EXPOSURE RATE

+ IN GROUP (mR/5td,Otr.) +-5td.Dev.

B-2 14.2 +- 1.5 7

2-5 14.9 +- 1.7 9

>5 13.B +- 1.0 10 UPHIND CONTROL DATR

!?.1 +

.6 3

110 SEABROOK TLD' DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831216-840412 118 DAYS FIELD TIME 98 DAYS NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deg.)

(mi.)

+- Rdm; Tot.

+- Rdm 15.0 + ; Tot.

001

-15r

.7 20.4 +-

.6 ;

3.1

.7 ;

3.3 002 179

.7 19.8 +-

.6 3.0 14.4 +-

.7 3.3

.6 ;

.7 ;

003 199

.7 18.5 +-

2.8 13.3 +-

.6 ;;

3.1

.7 ;;

004 223

.9 20.2 +-

3.0 14.8 +-

3.3 005 244 1.2 19.8 +-

.6 ;

3.0 14.4 +-

.7 3.3

.6' 3.0 14.4 +-

.7 ;

006 293 1

19.8 +-

3.3

.6 ;

.7 ;;

007 275

.5 18.7 +-

2.8 13.5 +-

008 317 2.8 19.3 +-

.6 ;

3.2 2.9 14.0 +-

.7 3.2 009 331 1.6 24.3 9

.7-:;

,8j; 3,6 1836 +-

3.8 010 358 1.9 19.4 +-

.6 l

.6 2.9 14.1 +-

.7, 3.2 011 20 2.6 20.1 +-

3.0 14.7 +-

.7 3.3

.6 ;;

.7 ;;

012 50 2.1 19.3 +-

2.9 14.0 +-

3.2 013 82 1.7 19.9 +-

.6 3.0 14.6 +-

014 43 4.1 20.1 +-

.6 ;

.7 3.3

.7 ;

3.0 14.7 +-

.6 ;;

3.3

.7 ;;

015 0

4 20.1 +-

3.0 14.7 +-

3.3 016 20 12.

20.7 +-

.6 ;

3.1 15.3 +-

.7 3.4

.7' 3.4 16.9 +-

.7 ;

017 322 7.3 22.4 +-

.6 ;;

3.6

.7 ;;

018 292 3.9 21.0 +-

3.1 15.5 +-

3.4 019 269 9.9 20.7 +-

.6-3.1 15.3 +-

.7 ;

3.4 020 253~

4.2 MISSINGORDAf1AGEDDOSIMETER 021 232 4.7 19.8 +-

.6 ;

3.0 14.4 +-

.7-3.3

.7 3.3 16.7 +-

.7 ;

022 213 6.1 22.3 +-

.6 ;;

3.6

.7 ;;

023 189 6.6 21.6 +-

3.2 16.1 +-

3.5 024 166 7.2 19.0 +-

.6 ;

2.8 13.7 +-

.7 ;

3.2 025 177 4.1 19.8 +-

.6 3.0 14.5 +-

.6 ;;

.7 3.3

.7 ;;

026 159 4

19.3 +-

2.9 14.0 +-

3.2 027 138 2.4 20.4 +-

.6 3.1 15.0 +-

.7 ;

3.3

.6 ;

028 117 4.4 19.0 +-

2.9 13.7 +-

.6 ;;

.7 3.2

.7 ;;

030 66 2.1 20.0 +-

3.0 14.7 +-

3.3 031 336 5.4 21.5 +-

.6 ;

3.2 16.0 +-

.7 3.5 032 237 18, 22.7 +-

.7 3.4 17.1 +-

.8 ;

033 237 18, 20.7 +-

.6 ;

3.6

.7 ;

3.1 15.3 +-

034 237 18.

20.8 +-

.6 ;

3.4

.7 ;;

3.1 15.4 +-

3.4 TRANSIT DOSE =

4.0

+-

.5 ; 2.0 t

111

SEABROOK FOR,THE PERIOD 831216-840412

.TLD DIRECT RADIATION ENVIRONMENTAL MONITORING AZIMUTH (dag.).

NET RVER. EXPOSURE RATE 4 IN GROUP

-(mR/Std.Qir.) t-Std.Dav.

348.75-11.25 -(N)

,14.4 +

.4 2

11.25-33.75 (NNE) 15.B +

.4 2

33.75-56.25 (NE) 14.4 +

.5 2

56.25-78.75 (ENE) 14.7 +- B.O 1

78.75-101.25 (E) 14.6 +- B.O 1

101.25-123.75(ESE) 13.7 +- B.O 1

123,75-146.25(SE) 15.0 +- B.O 1

14 5.25-158.75 ( 55 E )

14.2 +

.7 3

158.75-191.25(5) 15.5 4-1.0 3

19L.25-213.75(55N) 15.B 4-2.4 2

213.75-236.25(SN) 14.6 +

.3 2

238.25-258.75 ( W5 H )

14.4 +- B.O 1

258.75-281.25(W) 14.4 +- 1.3 2

281.25-303.75 ( H N LJ )

15.B +

.8 2

303.75-328.25(NH) 15.4 +- 2.0 2

326.25-348.75(NNN) 17.3 +- 1.8 2

DISTANCE (mi) FROM THE REACTOR NET AVER. EXPOSURE RATE

+ IN GROUP (mR/5td.0tr.) +-Std.Dev.

B-2 14.7 +- 1.5 10 2-5 14.5 +

.5 12

>5 15.7 +- 1.1 7

UPNIND CONTROL DATA 15.9 +- 1.0 3

m

11~2 SEQUOYAH TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831214-840427 135 DRYS FIELD TIME 105 DAYS' NRC-LOCATION.

GROSS NET EXPOSURE RRTE STATION fi2IMUTH/DIST EXPOSURE (mR) mR/St d. 0t r.

(deg.)

(mi.)

+- Rda; Tot.

+- Rdm; Tot.

001 218 11.

MISSING OR DAMAGED DOSINETER 002 206 13.

18.4 +-~

.6 2.8 13.2 +-

.7 ;;

.6 2.9

.7 ;;

003 203 3.9 24.8 +-

3.7 18.8 +-

3.6 004 199 2.0 22.3 +-

.7 ;

3.3 16.6 +-

.7 ;

3.3 005 181 1.4 27.6 +-

.8 4.1 21.1 +-

.6 ;

.8 3.9 2.9 14.2 +-

.6 ;

006 153 1.5 19.5 +-

.5 ;

3.0

.6 ;;

007 139 1.9 17.8 +-

2.7 12.8 +-

2.8 008 115 1.8 MISSING OR DAllAGED DOSIMETER 009 84 1.6 18.6 +-

.6 2.8 13.4 +-

.6 2.9

.6 ;;

.6 ;

010 66 1.3 19.0 +-

2.8 13.7 +-

2.9

.7 ;

011 45 1.5 21.5 +-

.6 3.2 15.9 +-

.7 ;

3.2 3.4 16.9 +-

.7 ;

012-14 2.t 22.6 +-

3.3

.7 ;;

013 2.0 2.1 23.2 +-

. 7 ;'

3.5 17.4 +-

3.4 014 19 3.9 19.2 +-

.6 ;

2.9 14.0 +-

.6 3.0

.6 ;

015 48 4.9 18.4 +-

.6 2.8 13.3 +-

016 65 4.9 19.8 +-

.6 ;

2.9 3.0 14.5 +-

.6 ;

.6 ;

3.0

.7 ;

017 90 3.9 21.4 +-

3.2 15.8 +-

.6 ;;

3.2

.6 ;;

018 111 3.4 19.2 +-

2.9 14.0 +-

3.0 019 135 3.4 19.6 +-

.6 2.9 14.3 +-

.6 3.0

.5 ;*

.6 ;;

020 158 3.4 16.6 +-

2.5 11.7 +-

2.7 021 184 4.6 MISSING OR DAllAGED DOSIMETER 022 233 10.

18.6 +-

.6 2.8 13.4 +-

.6 ;;

.6 2.9

.6 ;;

023 219 4.9 20.3 +-

3.0 14.9 +-

3.1 024 241 4.3 19.3 +-

.6*

2.9 14.0 +-

.6 ;

3.0 025 235 2.0 MISSIllG OR DAllAGED DOSIMETER 026 248 1.5 MISSING OR DAMAGED DOSIMETER 027 266 1.2 18.0 +-

.5 2.7 12.9 +-

.6 ;;

.6 2.8

.6 ;;

028 291 1.2 19.5 +-

2.9 14.2 +-

3.0 029 309 1.2 20.1 +-

.6 3.0 14.7 +-

.6 ;

3.0 030 330 0.5 20.5 +-

.6 ;

3.1 15.1 +-

.6 ;

3.1

.6 ;;

031 339 1.8 20.7 +-

3.1 15.2 +-

.7 3.1 032 355 4.9 17.9 +-

.5 2.7 12.8 +-

.6 ;

033 334 3.6 17.8 +-

.5 ;

2.8

.6 ;;

2.7 12.8 +-

.5 ;;

2.8 034 317 4.4 17.3 +-

2.6 12.3 +-

.6 2.8

.6 ;

035 277 5.6 19.9 +-

.6 ;

3.0 14.6 +-

3.0

.5 2.7 13.0 +-

.6 ;

036 283 3.6 18.1 +-

.6 ;

2.8 2.8 13.5 +-

.6 ;

037 273 4.4 18.7 *-

.6 ;;

2.9

.6 ;;

038 302 19.

18.4 +-

2.8 13.3 +-

2.9 039 290 18 19.9 +-

.6 3.0 14.5 +-

.6 3.0

.6 ;;

.6 ;;

040 289 18 19.8 +-

3.0 14.4 +-

3.0 041 318 6.1 19.3 +-

.6 ;

2.9 14.0 +-

.6 ;

3.0 TRANSIT DOSE =

2.9

+-

.4 ; 1.9

113-SEQUOYAH FOR THE PERIOD 831214-840427 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (deg. )

NET RVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qsr.) t-Std.Dav.

348.75-il.25 (N) 15.1 +- 3.2 2

11.25-33.75 (NNE) 15.4 +- 2.1 2

l I

33.75-56.25 (NE) 14.6 +- 1.8 2

56.25-78.75 (ENE) 14.1 +

.5 2

78.75-10l.25 (E) 14.E +- 1.7 2

10l.25-123.75(ESE) 14.8 +- B.0 1

123.75-148.25 ( S E )

13.5 +- 1.1 2

14 5.25-158.75 ( 55E )

12.9 +- 1.7 2

158.75-191.25(5) 2l.1 4-B.O 1

191. 25-2 l 3.75 ( 55N )

15.2 4-2.8 3

213.75-236.25(SW) 14.1 +- 1.0 2

236.25-258.75 ( W 5W )

14.9 +- G.O 1

258.75-281.25(W) 13.7 +

.B 3

28L.25-303.75(WNW) 13.E +

.B 2

303.75-328.25(NN) 13.7 +- 1.2 3

326.25-348.75(NNN) 14.3 +- 1.4 3

f DISTRNCE(mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/5td,0tr.) +-Std.Dev.

B-2 15.1 +- 2.2 13 2-5 14.2 +- 1.8 16 i

>5 13.8 +

.6 4

UPHIND CONTROL ORTA 14.1 +

.7 3

114 SHOREHAM TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831215-840420 127 DAYS FIELD TIME 76 DAYS NRC -

LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tP.

(deo.)

(mi.)

+- Rdm; Tot.

+- Rdm 13.2 + ; Tot.

001 262 10 18.4 +-

.6 ;

2.8

.8 ;

4.1 002-268-4.4 19.3 +-

.6 2.9 14.3 +-

.9 4.2

.6 ;

2.8 13.6 +-

.9 ;

003 256

- 3. 2 18.7 +-

.6 ;

4.1

.8 ;;

004 268 2.1 18.4 +-

2.8 13.3 +-

4.1

.6 ;

005 243 1.7 18.9 +-

2.8 13.9 +-

.9 4.2

.5 ;.2.6

.8 ;

007 136 1.5 17.3 +-

11.9 +-

3.9

.6 ;;

.9 ;

008 116 0.9 20.3 +-

3.0 15.5 +-

4.3 1

.8 ;

009 910 0.8 18.0 +-

.5 2.7 12.8 +-

4.0

.5 ;;

.8 ;;

010 730 0.7 17.5 +-

2.6 12.2 +-

3.9 011 62.

0.7 17.3 +-

.5 ;

2.6 12.0 +-

.8 ;

3.9 012 75 1.6 17.6 +-

.5 2.6 12.3-+-

.8 4.0

.013 88 2.1 18.7 +-

.6 ;

.9 ;

2.8 13.6 +--

.5 ;

.8 ;

4.1 014 119 4.6 17.5 +-

2.6 12.2 +-

3.9

.6 ;;

.9 ;;

015 110 10.

18.9 +-

2.8 13.9 +-

4.2 016 138' 14.

18.3 +-

.5 ;

2.7 13.2 +-

.8 4.1

.8 ;

017 162 11.

17.3 +-

.5 ;

2.6 12.0 +-

3.9

.8 ;

018 170 11.

17.8 +-

.5 ;

2.7 12.6 +-

.9 ;;.4.0 019 189 5.1 18.8 +-

.6 2.8 13.7 +-

.5 ;

4.1 021 163 2.5 17.3 +-

2.6 12.0 +-

.8 3.9 022 149 1.5 18.7 +-

.6 ;

2.8 13.6 +-

.9 ;

.6 ;

4.1

.9 ;

023 177 1.3 18.9 +-

2.8 13.8 +-

.5 ;;

.8!'4.1 024 196 1.2 17.9 +-

2. 7 12.6 +-

4.0 025 217 1.5 18.9 +-

.6 2.8 13.9 +-

.9 4.2

.5 ;;

2.4 10.6 +-

.8 ;

026 215 4.6 16.2 +-

3.8

.9 ;

027 205 4.2 19.3 +-

.6 ;

2.9 14.4 +-

4.2

.5 2.6 12.0 +-

.8 ;

028 233 11 17.4 +-

.5 ;;

3.9

.8 ;;

029 224 12.

17.5 +-

2.6 12.2 +-

4.0 030 202 14.

18.3 +-

.5 ;

2.7 13.2 +-

.8 4.1

.8 ;;

031 210 15.

17.6 +-

.5 2.6 12.3 +-

032 210 15.

17.9 +-

.5 ;

4.0 2.7 12.7 +-

.8 ;

4.0

.5 ;

033 210 15.

17.7 +-

2.6 12.4 +-

.8 ;

4.0 034 27

.2 MISSINGORDAb6GEDDOSIMETER 035 50

.3 MISSING OR DAMAGED DOSIMETER 036 133 3.9 19.1 +-

.6 ;

2.9 14.1 +-

.9 ;

4.2 TRANSIT DOSE =

7.2

+-

.5 ; 2.1 i

1 i

i t

115 SHOREHAM FOR THE PERIOD 831215-840420 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING

[

RZIMUTH (deg. )

NET AVER. EXPOSURE RATE 4 IN GROUP (mR/St.d.Qtr.) t-Std.Dev.

348.75-11.25 (N) 12.5 +

.4 2

l 11.25-33.75 (NNE)

NO DRTA+-NO DATR S'

33,75-56.25 (NE)

NO DATA +-NO DATR S

56.25-79.75 (ENE) 12.2 +

.3 2

78.75-101.25 (E) 13.6 +- B.O 1

10l.25-123.75(ESE) 13.B +- 1.7 3

123,75-146.25(SE) 13.1 +- 1.1 3

146.25-168.75 ( 55 E )

12.5 +

.5 3

168.75-191.25(5) 13.4 +

.7 3

19t.25-2l3.75(55N) 13.4 +

.5 3

213.75-236.25(SW) 12.2 +- 1.3 4

236.25-258.75(W5W) 13.7 +

.2 2

258.75-281.25(W) 13.5 +

.5 3

28L,25-303.75(WNW3 NO DATAt-NO DATR S

303.75-326.25(NN)

NO DATRt-NO DATR E

326.25-348.75(NNN)

NO DATA +-NO DATR 0

02 STANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP

( mR/ 5t d. Q t r. ) '+-St d. De v.

B-2 13.1 +- 1.1 11 2-5 13.1 +- 1.3 9

>5 12.B +

.7 9

t UPHIND CONTROL ORTA 12.5 +

.2 3

i

q 116 SUMMER TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831213-840504 143 DAYS FIELD TIME 98 DAYS 3

1 HRC LOCATION GROSS NET EXPO 5URE RATE i

STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.-

i (deg.)

(mi.)

+- Rdm; Tot.

+- Rdm; Tot.

j 001 19y 3.7 MISSING OR DAMAGED DOSIMETER i

002 111 1.0 25.6 +-

.8' 3.8 19.6 +-

.8 ;

4.1 003 340 4.1 MISSINGORDAbAGEDDOSIMETER 004 192 9.3 25.9 +-

.8 3.9 19.9 +-

.8 4.1 i

.8 ;;' 4.2

.9 ;;

005 72 1.8 28.3 +-

22.1 +-

4.4 006 54 1.5 25.1 +-

.8 3.8 19.2 +-

.8-4.0 007 46 3.0 31.7 +-

1.0 ;

1.0 ;;

4.8 25.3 +-

4.8 008 31 3.0 MISSINGORDAbAGEDDOSIMETER 009 13 3.9 31.9 +-

1.0 ;

4.8 25.4 +-

1.0 4.8 25.0 +- -1.0 ;;

010 7

4.0 31.5 +-

.9 4.7 4.8 011 349 4.3 25.3 +-

.8 ;

3.8 19.4.+-

.8 ;

4.0 012 323 5.0 MISSINGORDAbAGEDDOSIMETER 013 333 3.0 29.4 +-

.9 ;

4.4 23.1 +-

.9 ;

4.5 014 255 2.8 20.0 +-

.6-3.0 14.5 +-

.7 3.4

.8 ;;

4.2 22.1 +-

.9 ;

015 308 5.6 28.3 +-

4.4

.9 ;

016 64 3.5 28.4 +-

.9 4.3 22.2 +-

4.4

.8 ;;

.9 ;

017 98 3.1 27.7 +-

4.2 21.6 +-

4.3

.8 4.0 20.8 +-

.9 ;

018 114 3.5 26.9 +-

4.2

.8 ;;

.9 ;;

019 132 2.0 26.5 +-

4.0 20.4 +-

4.2 020 152 4.5 18.9 +-

.6 ;

2.8 13.5 +-

.7 3.3

.7 ;

021 133 4.1 19.7 +-

.6 3.0 14.2 +-

3.4 022 157 2.4 22.1 +-

.7 ;

.8 ;;

3.3 16.4 + -

3.6

.7 ;;

023 173 2.4 23.6 +-

3.5 17.8 +-

.8 3.8 024 185 3.9 23.5 +-

.7 3.5 17.7 +-

.8 ;

3.8 025 210 3.3 23.2 +-

.7 ;

.8 ;;

3.5 17.5 +-

3.8

.6 ;;

026 217 3.3 20.7 +-

3.1 15.1 +-

.7 ;

3.5 027 231 3.1 20.8 +-

.6 3.1 15.2 +-

.7 3.5 028 267 2.7 25.8 +-

.8 ;

.8 ;

3.9 19.8 +-

4.1

.8 ;;

.8 ;;

029 276 3.4 26.0 +-

3.9 20.0 +-

4.1 030 293 3.8 28.7 +-

.9 ;

4.3 22.5 +-

.9 ;

4.4 031 244 3.6 22.5 +-

.7 ;

3.4 16.8 +-

.8 ;

3.7 032 247 6.2 25.4 +-

.8 3.8 19.5 +-

.8 4.0 033 218 9.0 24.7 +-

.7 ;

.8 ;

3.7 18.8 +-

4.0 034 192 9.3 21.9 +-

.7 ;

.8 ;

3.3 16.3 +-

3.6

.6 ;;

.7 ;

035 184 14, 20.1 +-

3.0 14.6 +-

3.4

.7 ;;

036 183 14.

19.4 +-

.6 2.9 13.9 +-

3.3

.6 ;;

037 182 14.

19.3 +-

2.9 13.8 +-

.7 ;

3.3 038 148 20, 27.1 +-

.8 ;

4.1 21.0 +-

.9 4.2

.8 ;

039 140 25.

25.2 +-

.8 3.8 19.2 +-

4.0

.9 ;;

.9 ;;

040 135 23.

29.5 +-

4.4 23.2 +-

4.5 TRANSIT DOSE =

4.2

+-

.5 ; 2.2

117 SUMMER FOR THE PERIOD 831213-840504 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING AZIMUTH (dag.)

flET AVER. EXPOSURE RATE

$ IN GROUP (mR/Std.Qtr.) t-Std.Dav.

348.75-11.25 (fD 22.2 +- 4.0 2

11.25-33.75 (NrJE) 25.4 +- 0.0 1

33.75-56.25 (f4E) 22.2 +- 4.3 2

56.25-78.75 (ENE) 22.2 +

.0 2

78.75-10l.25 (E) 21.6 +- 0.0 1

101.25-123.75(ESE) 20.2 +

.9 2

123.75-146.25(SE) 19.3 +- 3.7 4

14 6.25-168. 75 ( 55 E )

17.0 4-3.0 3

168.75-191.25(5) 17.7 4-

.0 2

l 191.25-213. 75 ( 55 N )

17.9 +- 1.0 3

213.75-236.25(SH) 16.4 +- 2.1 3

236.25-250.75(14514) 16.9 +- 2.5 3

258.75-281.25(10 19.9 +

.1 2

28 l.25-303.75 (11NLO 22.5 +- 0.0 1

303.75-328.25(NH) 22.1 +- 0.0 1

326.25-348.75(NNN) 23.1 +- 0.0 1

DISTANCE (mt) FROM THE REACTOP NET RVER. EXPOSURE PATE

+ IN GROUP

( rnR/ St d. 0 t r. ) + -51 d. De v.

B-2

20. 3 +- 1. 3 4

2-5 19.2 +- 3.0 21

>5 20.D +- 2.1 8

UPNIND CONTROL ORTA 14.1 +

.4 3

118 SURRY TLD DIRECT RADIATION ENVIRONMENTAL MCNITORING

FOR THE PERIOD 831214-840411 119 DAYS FIELD. TIME 84 DAYS

.NRC LOCATION GROSS

-HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

13.4 + ;Tcit.-

(deg.).(mi.)

+- Rdm; Tot.

'+- Rdm 001 118 18.

17.9 +-

.5

  • 2.7

.7 ;

3.5 002 129-17.

MISSING OR DAllAGED DOSIMETER 003 162 16.

18.6-+-

.6 ;

2.8 14.2 +-

.7 ;

3.6

.4.

2.2 9.7 +-

.6 ;

3.1 004 162 16.

14.4 +-

.6 ;;

005 156 5.1 19.6 +-

2.9 15.3 +-

.8 ;

3.7 006 189 4.1 16.3 +-

.5 ;

2.4 11.8 +-

.7 ;

3.3 007 202 2.2 15.6 +-

.5 2.3 11.0 +-

.7 ;

3.2

.5 ;

008 183 1.6 18.? +-

2.7 13.9 +-

.7 ;

3.5

.6 ;

009 243 0.2 21.7 +-

3.2 17.5 +-

.8 4.0

.9;

.8 ;

3.8 21.6 +-

010 269 0.1 25.5 +-

4.6 1.0 ;;

4.8

.8 ;;

011 304 0.1 27.1 +-

4.1 23.4 +-

012 334 0.2 24.0 +-

.7 3.6 20.0 +-

.9, 4.3

.5 ;

4 013 10 1.2 18.3 +-

2.7 13.9 +-

.7 ;

3.6

.6 ;

014 21 2.0 18.4 +-

2.8 14.0 +-

.7 ;

3.6

.5 ;

015 203 4.5 17.0 +-

2.5 12.5 +-

.7 3.4

.7.;

.9 ;

016 224 3.7 22.9 +-

3.4 18.8 +-

4.2 017 212 2.0 18.8 +-

.6 ;

.8 ;

3.6 2.8 14.4 +-

.5 ;

.7 ;

4 018 248 5.1 17.1 +-

2.6 12.6 +-

3.4

.5 ;

.7 ;

019 259 8.1 17.8 +-

2.7 13.4 +-

3.5 i

020 285 5.0 MISSINGORDAl1AGEDDOSIMETER 021 270 4.1 MISSING OR DAMAGED DOSIMETER 022 123 12.

20.4 +-

.6 ;

3.1 16.2 +-

.8 '

.9 l 3.8 023 102 11.

23.8 +-

.7 3.6 19.8 +-

4.3

.6 ;

024 106 4.9 19.2 +-

2.9 14.9 +-

.8 3.7

.6 ;

.7 ;

025 90 5.2 18.4 +-

2.8 14.0 +-

3.6

.7 ;

.9 ;

026 69 5.1 22.4 +-

3.4 18.3 +-

4.1 027 23 5.3 19.8 +-

.6 ;

.8 ;

3.0 15.5 +-

3.8

.6 ;

.8 ;;

028 49 5.0 20.9 +-

3.1 16.7 +-

3.9

.6 ;

029 7.0 6.8 20.7 +-

3.1 16.5 +-

.8 ;

3.9 030 359 6.5 17.6 +-

.5 ;

2.6 13.1 +-

.7 ;

3.5

.4 ;

031 1.0 4.6 14.4 +-

2.2 9.7 +-

.6 ;

3.1

.5 ;

032 332 3.8 17.1 +-

2.6 12.6 +-

.7 ;

3.4

.6 ;

033 314 5.4 19.9 +-

3.0 15.6 +-

.8 ;

3.8 034 308 6.4 MISSING OR DAllAGED LOSIMETER 1

035 348 5.3 17.4 +-

.5 2.6 12.9 +-

.7 ;

3.4

.5 ;;

036 343 14, 17.8 +-

2.7 13.4 +-

.7 ;

3.5 037 340 15.

17.6 +-

.5 ;

2.6 13.2 +-

.7 ;

3.5 038 339 15.

17.4 +-

.5 ;

2.6 12.9 +-

.7 ;

3.4

)

039 153 1.9 21.1 +-

.6 ;

3.2 16.9 +-

.8 3.9

.7 ;

i 040 144 2.1 17.6 +-

.5 ;

2.6 13.2 +-

3.5 TRANSIT DOSE =

5.3

+-

.4 ; 1.9 1

119 SURRY:

FOR THE PERIOD 831214-840411 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dag.)

NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dav.

348.75-11.25 (N) 13.3 +- 2.8 4

11.25-33.75 (NNE) 14.5 +- 1.1 2

33.75-56.25 (NE) 16.7 +- B.O 1

56.25-78.75 (ENE) 18.3 +- 8.0 1

78.75-101.25 (E) 14.0 +' B.O 1

10l.25-123.75(ESE) 16.1 +- 2.7 4

123.75-146.25(SE) 13.2 +- B.O 1

14 6.25-168.75 ( 55E )

14.5 4-3.1 4

168.75-191.25(5) 12.5 +- 1.5 2

ISL.25-213.75(55N) 12.5 4-1.7 3

213.75-236.25(SW) 10.8 +- B.O 1

236,25-258.75(WSW) 15.1 +- 3.5 2

258.75-201.25(W) 17.5 +- 5.0 2

28L.25-303.75(WNW)

NO 11RTAt-NO DATR B

303.75-326.25(NH) 19.5 +- 5.5 2

326.25-348.75(NNN) 15.2 +- 4.2 3

DISTANCE (mt) FROM THE REACTOR NET RVER.EXPOSUPE PATE

+ I N GR O UP (mR/Std,Qtr.) + -5t d. De v.

B-2 17.3 +- 3.6 9

2-5 13.5 +- 2.9 9

>5 14.7 +- 2.5 15 UPNINO CONTROL DATA 13.2 +

.2 3

120 SUSQUEHANNA TLD DIRECT RADIATION ENVIRONMENT 6L MONITORING FOR THE PERIOD 831212-840411 121 DAYS FIELD TIME 105 DAYS NRC

-LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

15. 8 + ; Tc t.

+- Rdm (deg.)

(mi.)

+- Rdm; Tot.

001 19 1.4 20.9 +-

.6 ;

3.1

.6 ;

3.1 002 0

1.4 21.2 +-

.6 ;

3.2 16.1 +-

.7 3.1

.6 ;'

003 333 1.7 20.7 +-

.6 ;

3.1 15.6 +-

3.1

.7 l 2.9 004 318 1.7 18.9 +-

.6 ;

2.8 14.1 +-

.6 005 287 1.7 22.0 +-

.7 3.3 16.8 +-

3.2

.7 ;

3.3 16.7 +-

.7 !

3.2 006 270 1.3 21.9 +-

.6 ;

007 239 1.8 20.5 +-

3.1 15.5 +-

.6 ;

3,0

.7 ;

008 217 2

24,9 +-

3.7 19.2 +-

.7 l 3.5

.7*

.6 ;

009 200 1.4 21.7 +-

3.2 3.2 16.5 +-

010 175 1.2 20.9 +'

.6 ;

3.1 15.8 +-

.6 ;

3.1

.6 ;

3.2 16.1 +-

011 243 5.1 21.2 +-

.7 3.1

.6 ;

.6 ;;

012 252 4.7 21.0 +-

3.1 15.9 +-

3.1

.8 ;

013 274 3.4 25.7 +-

.8 ;

3.9 19.9 +-

3.6

.7 ;

014 286 3.6 22.7 +-

.7 3.4 17.4 +-

3.3 015 2

3.8 22.8 +-

.7 ;

3.4 17.4 +-

.7 ;

3.3

.7 ;

.7 ;

016 334 4.1 22.0 +-

3.3 16.8 +-

3.2

.6 ;

.7 *;

017 312 4.4 21.7 +-

3.2 16.5 +-

3.2

.7 ;

I 018 32 4.9 22.5 +-

.7 l 3.4 17.2 +-

.7 l 3.3 019 45 9.9 23.8 +-

3.6 18.3 +-

.7 3.4 020 65 4.8 25.5 +-

.8 '

3.8 19.7 +-

.7 ;

3.6

.6 l 3.0 021 44 3.1 25.6 +-

.8 3.8 19.8 +-

.8 3.6

.6 l';3.0 022 47

.7 20.2 +-

15.2 +-

.6 ;;

023 65 1.2 20.7 +-

3.1 15.6 +-

.6 3.1 024 87 1.4 22.9 +-

.7 ;

3.4 17.5 +-

.7 ;

3.3 025 108 1.4 21.5 +-

.6 ;

3.2 16.3 +-

.7 ;

3.1 026 137 1.5 23.2 +-

.7 ;

3.5 17.8 +-

.7'

.7 l 3.3 027 152 1.5 23.3 +-

.7*

3.5 17.9 +-

3.4 028 108 3.7 MISSINGORDAbAGEDDOSIMETER 029 102 4.3 23.4 +-

.7 3.5 18.0 +-

.7 ;

3.4

.7 ;;

030 140 4.3 22.9 +-

3.4 17.5 +-

.7*

3.3

.7 l 3.4 031 162 3.4 23.2 +-

.7 ;

3.5 17.8 +-

3.3 032 176 3.5 23.4 +-

.7 ;

3.5 17.9 +-

.7 *I 033 192 3.1 24.2 +-

.7 ;

3.6 18.6 +-

.7 3.5 I

034 231 4.4 22.3 +-

.7 ;

3.3 17.0 +-

.7 3.2 I

035 134 12, 22.4 +-

.7 ;

3.4 17.1 +-

.7 3.2 036 114 13.

25.4 +-

.8 ;

3.8 19.6 +-

.7,I 3.6 037 150 15.

21.8 +-

.7 ;

3.3 16.6 +-

.7 ;

3.2 TRANSIT DOSE =

2.5

+-

.4 ; 1.8 r

i

121 SUSQUEHANNA FOR THE PERIOD 831212-840411 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dog.)

NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-!!.25 (N) 16.7 +

.5 2

11.25-33.75 (NNE) 16.5 +- 1.0 2

33.75-56.25 (NE) 17.8 +- 2.4 3

56.25-78.75 (ENE) 17.7 +- 2.9 2

78.75-10(.25 (E) 17.5 +- G.0 1

lOL.25-123.75(ESE) 17.1 +- 1.2 2

123,75-146.25 ( S E )

17.8 +

.2 2

145.25-158.75 ( 55E )

17.5 +

.1 2

168.75-191.25(5) 15.9 +- 1.5 2

15L 25-213.75(55N) 17.5 +- 1.5 2

213.75-236.25(SN) 10.1 4-1.6 2

236.25-258.75(WSW) 15.8 +

.3 3

258.75-281.25(W) 18.3 +- 2.3 2

28L 25-303.75(WNW) 17.1 +

.4 2

303.75-326.25(NN) 15.3 +- 1.7 2

326.25-348.75(NNN) 16.2 +

.B 2

DISTANCE (mi) FROM THE REACTOR PET AVER. EXPOSURE PATE 4 IN GROUP (mR/5td.Qtr.) + -S t d. De v.

8-2 16.4 +- 1.2 15 2-5 17.5 +- 1.2 15

>5 17.2 +- 1.6 2

UPNIND CONTROL ORTA 17.8 +- 1.6 3

7 122 THREE t1ILE ISLAND TLD DIRECT RADIATION ENVIROHl1 ENTAL t10HITORIllG FOR THE PERIOD 831212-840411 121 DAYS FIELD TItIE 107 DAYS HRC LOCATION GROSS HET EXP05URE RATE STATI0t1 AZIt1UTH/DIST EXPOSURE (mR) mR/Std.0tr.

(deg.)

(mi )

+- Rdm; Tot.

13.2 + ; Tot.

+- Rdm

.6 ;

2.8 001 95 5.9 17.9 +-

.5 ;

2.7 002 101 3.9 22.2 +-

.7*

3.3 16.8 +-

.7 ;

3.2 003 109 2.7 t11SSING OR DAllAGED DOSIt1ETER 004 163 1.8 18.4 +-

.6 ;

2.8 13.6 +-

.6 ;

2.8

.6 2.7 005 161 2.2 17.5 +-

.5 ;

2.6 12.9 +-

.6 ;;

2.9 006 150 1

18.7 +-

.6 ;

2.8 13.9 +-

007 136

.6 16.8 +-

.5 ;

2.5 12.3 +-

.6 ;

2.7 008 83

.4 17.0 +-

.5 ;

2.6 12.4 +-

.6 ;

2.7 009 60

.5 17.3 +-

.5 '

2.6 12.7 +-

.6 ;

2.7 010 1

1.7 18.0 +-

.5 ;

2.7 13.2 +-

.6 ;

2.8 011 25

.9 17.5 +-

.5 ;

2.6 12.8 +-

.6 ;

2.7 012 46 2.8 18.9 +-

.6 ;

2.8 14.0 +-

.6 ;

2.9

.6 2.8 13.7 +-

.6 ;

2.8 013 19 5.2 18.5 +-

.5 ;;

2.6 12.6 +-

.6 ;

2.7 014 358 2.5 17.2 +-

015 133 9.0 21.9 +-

.7 ;

3.3 16.5 +-

.7 ;

3.2 016 0

3.1 18.7 +-

.6 ;

2.8 13.8 +-

.6 ;

2.8 018 349 3.5 21.0 +-

.6 ;

3.2 15.8 +-

. 7 ;' 3.1

.6 3.0 019 343 3.2 19.7 +-

.6 ;

2.9 14.7 +-

.6 ;;

2.8 020 318 5

18.3 +-

.5 ;

2.7 13.5 +-

021 348 1.3 15.2 +-

.5 ;

2.3 10.9 +-

.5 ;

2.5 022 17 3.1 18.8 +-

.6 ;

2.3 13.9 +-

.6 ;

2.9 023 64 3.8 15.9 +-

.5 ;

2.4 11.5 +-

.6 ;

2.6 024 44 3.6 20.4 +-

.6 '

3.1 15.3 +-

.6 ;

3.0 025 335 0.5 t1ISSIllG OR DAl1 AGED DOSIt1ETER 027 006 7.4 23.1 +-

.7

  • 3.5 17.6 +-

.7 ;

3.3 029 293 0.4 LIISSIllG OR DAllAGED DOSil1ETER 030 317 1.2 t11SSING OR DAt1 AGED DOSIIIETER 031 306 9.6 16.4 +-

.5 ;

2.5 11.9 +-

.6 ;

2.6 032 297 7.4 20.1 +-

.6 ;

3.0 15.0 +-

.6 ;

3.0 033 301 5.9 16.9 +-

.5 ;

2.5 12.4 +-

.6 ;

2.7

.6 2.9 14.3 +-

.6 ;

2.9 034 267 2.3 19.3 +-

.6 ;

2.3 14.0 +-

.6 ;

2.9 035 299 1.8 18.9 +-

.4 ;

2.2 10.5 +-

.5*

2.5 036 267 1.2 14.7 +-

.5 ;

2.5 12.3 +-

.6 !

2.7 037 256 1.4 16.8 +-

.6 ;;

3.1 15.3 +-

.6 ;

3.0 038 225 1.9 20.5 +-

039 200 2.1 15.6 +-

.5 ;

2.3 11.2 +-

.5 ;

2.5 040 204 2.5 17.4 +-

.5 ;

2.6 12.7 +-

.6' 2.7 041 185 13.

19.5 +-

.6 ;

2.9 14.5 +-

.6 l 2.9

.7 l 2.8

.f '

042 259 7.3 18.6 +-

.6 ;

2.3 13.8 +-

3.1 043 268 5.8 21.5 +-

.6 j 3.2 16.2 +-

044 263 4.7 17.2 +-

.5 2.6 12.6 +-

.6 ;

2.7 045 230 0.5 IIISSING OR DAl1 AGED 00$lt1ETER 046 177 3

17.7 6-

.5 ;

2.6 13.0 +-

.6 ;

2.7 047 177 5.7 18.7 +-

.6 ;

2.8 13.8 +-

.6 ;

2.8 048 182 9

24.5 +-

.7*

3.7 18.7 +-

.7' 3.5 049 206 0.9 r11351HGORDAllAGEDDOSil1ETER

.5 ; 1.9 TRANSIT DOSE =

2.2

+-

123 THREE MILE ISLAND FOR THE PERIOD 831212-840411 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dog.)

NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qir.) t-Std.Dev.

348.75-il.25 (N) 14.5 +- 2.1 5

11.25-33.75 (NNE) 13.5 +

.I 3

33.75-56.25 (NE) 14.7 +

.5 2

56.25-78.75 (ENE) 12.1 +

.5 2

4 78.75-10l.25 (E) 14.1 +- 2.3 3

1.

101.25-123.75(ESE)

NO DATA +-NO DATA 8

123.75-146.25(SE) 14.4 +- 3.0 2

146.25-168. 75 ( 55 E )

.33.1 +

.5 3

169.75-191.25(5) 15.8 +- 2.5 4

191.25-213.75(55N) 12.5 +- 1.1 2

213.75-236.25(SW) 15.3 +- B.0 1

236.25-258.75(HSH)

No DRTAt-NO DATA 9

258.75-201.25(H) 14.2 +- 1.5 4

288.25-303.75(HNH) 13.7 +- 1.9 2

303.75-326.25(NN) 12.7 +- 1.1 2

326,25-348.75(NNN) 12.5 +- 2.7 2

4 O! STANCE (mt) FROM THE REACTOR NET RVER. EXPOSURE RMTE

+ IN GROUP

( rnR/ Etd. Q t r. ) + -5t d. De v.

B-2 13.9 +- 1.2 9

2-5 13.7 +- 1.5 15 55 14.5 +- 2.3

~

12

~

UPN!ND CONTROL DATA 12.3 +- 1.7 3

i i

,, ~ -,..

.......,-,,--,y

.___r_~___-

124 TROJAN' TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831208-840413 127 DAYS FIELD TIME 85 DAYS NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/St d.Qt r.

(deg.)

(mi.)

+- Rdm; Tot.

11.3 + ; Tot.

+- Rdm

.8 3.7 001 340 0.6 16.8 +-

.5 ;

2.5

.8 ;

3.9

-002 334 1.5 19.2 +-

.6 2.9 13.8 +-

.5 ;

2.5 11.4 +-

.8, 3.7 j

003 340 1.7 16.9 +-

.5 ;

2.5 11.4 +-

.8 ;

3.7 004 328 3.9 16.9 +-

I

.9 l' 4.0 005 308 4.6 20.0 +-

.6 3.0 14.7 +-

.6 ;l 3.0 006 312

-4.5 19.8 +-

.8 4.0

.6 14.5 +-

.8 4.0 007 267 4.6 19.4 +-

2.9 14.0 + -

.9 *;

008 274 3.8 21.1 +-

.6 3.2 15.8 +-

4.2

.6 ;

3.0 14.9 +-

.9 l 4.1 009 279 1.7 20.2 +-

.6 ;

3.0 14.8 +-

.9 ;

4.0 010 263 2.0 20.1 +-

.6 l 3.2 3.2 16.3 +-

.9 j 4.2 011 245 1.6 21.6 + -

012 223 1.2 21.1 +-

.6' 15.9 +-

.9 4.2

.8lI I

013 196 1.1 19.8 +-

.6 14.4 +-

4.0

.6 l 3.0

~

014 180 1.2

-18.5 +-

2.8 13.1 +-

.8 3.8 015 165 1.7 18.5 +-

.6' 2.8 13.1 +-

.8 3.8 4

I I

016 212 3.9 19.4 +-

.6 2.9 14.0 +-

.8 4.0 I

I 017 230 3.5 21.0 +-

.6 3.1 15.7 +-

.9 4.2 3

14.8 +-

.9 !

4.1 018 162 9.3 20.1 +-

.6 l 3.0 019 172 5.0 21.8 +-

.7 3.3 16.6 +-

.9' 4.3 I

020 334 5.8 18.7 +-

.6 ;

2.8 13.3 +-

.6 3.9 I

021 345 5.5 18.8 +-

.6' 2.8 13.4 +-

.8 3.9

.5 ;l 2.5 I

i 022 356 5.5 16.9 +-

.5 11.4 +-

.8 3.7 I

023 8

3.9 17.1 +-

2.6 11.6 +-

.8 3.7 I

)

024 15 3.7 17.6 +-

.5*

2.6 12.2 +-

.8 l 3.7

.8

.5l2.7 025 27 1.9 17.9 +-

12.5 +-

3.8 026 37 2.1 19.7 +-

.6 l 2.9 14.3 +-

.8 *I 4.0 1

027 60 2.9 20.0 +-

.6 3.0 14.6 +-

.9 4.0 I

i 028 55 4.5 18.7 +-

.6 ;

2.8 13.3 +-

.8 3.9 I

i 029 69 1.6 18.5 +-

.6' 2.8 13.1 +-

.8 3.8 I

I i

030 83 3.9 17.8 +-

.5 2.7 12.4 +-

.8 3.8 I

I 1.

031 93 2.7 20.7 +-

.6 3.1 15.4 +-

.9 4.1 I

I l

032 119 2.2 20.6 +-

.6 3.1 15.3 +-

.9 4.1 i

I I

i 033 106 5.3 18.6 +-

.6 l 2.8 13.2 +-

.8 3.9 I

i 034 134 2.5 17.4 +-

.5 2.6 11.9 +-

.8 3.7 I

1 035 145 4.7 18.4 +-

.6' 2.8 13.0 +-

.8 3.8 I

I 036 270 17.

20.8 +-

.6 3.1 15.5 +-

.9 4.1 I

I 037 270 17.

20.7 +-

.6 l 3.1 15.4 +-

.9 4.1

.7 3.4 17.3 +-

.9 l 4.4 038 270 17, 22.5 +-

TRANSIT DOSE =

6.1

+-

.5 ; 2.4 t

4 i

125 TROJAN FOR THE PERIOD 831208-840413 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (deg. )

NET AVER. EXPOSURE RATE

$ IN GROUP rmR/Std.Qtr.) t-Std.Dev.

l l

348.75-il.25 (N) 11.5 +

.1 2

l 11.25-33.75 (NNE) 12.3 +

.I 2

33.75-56.25 (NE) 13.0 +

.7 2

56.25-70.75 (ENE) 13.5 +- 1.1 2

78.75-lOL.25 (E) 13.5 +- 2.3 2

10 L.25-123.75 ( E SE) 14.2 +- 1.5 2

123.75-146.25(SE) 12.4 +

.7 2

145.25-168.75(55E) 13.5 4-1.2 2

168.75-191.25(5) 14.5 4-2.5 2

19t.25-2L3.7!(55N) 14.2 4

.3 2

213.75-236.25(SW) 15.0 +

.1 2

236.25-258.754W9W) 16.3 +- B.9 1

250.75-2A1.25(WJ 14.5 +

.7 4

2G L 25-303.75 (WNH)

No DRTAt-N0 DATR S

303,75-326.25(NH) 14.s +

.1 2

326.25-340.75(NNN) 12.4 +- 1.2 6

DISTANCE (mt) FROM THC REACTOR NET RVER.EkPOSUPE PATE

+ IN GROUP

( rnR / 5 t d, Q t r'. ) + -51 d. De v.

9-2 13.7 +- 1.6 la 2-5 13.9 +- 1.6 is

>5 13.7 +- 1.2 T

UPH1ND CONTROL DATA 16.1 +- 1.I 3

126 TURKEY POINT TLD DIRECT RADI ATI0tt EtiVIR0til1EllTAL 110t1ITORIt1G FOR THE PERIOD 831214-840413 121 DAYS FIElr) TIME 101 DAYS llRC LOCATI0tl GROSS tlET EXP05URE RATE STATI0tl AZIt1UTH/DIST EXPOSURE (mR) mR/Std.0tr.

(deg.)

(mi.)

+- Rdm; Tot.

+- Rdm

9. 4 + ; Tcit.

001 31u 1.3 14.3 +-

.4 ;

2.1

.6 ;

2.6 002 292 2.4 l11SSIllG OR DAl1 AGED D0$111ETER 003 340 1.9 13.8 +-

.4 2.1 9.0 +-

.6 j 2.6

.4 *;

004 354 2.0 13.4 +-

2.0 8.6 +-

.6, 2.5 3

005 314 3.8 13.9 +-

.4 2.1 9.0 +-

.6 ;

2.6 006 331 4.2 t!!SS!tlGORDAllAGEDDOSIl1ETER 007 291 5.4 14.9 +-

.4*

2.2 9.9 +-

.6 ;

2.7 008 263 5.1 111SSillG OR DAllAGED DOSIl1ETER 009 242 5.7 13.8 +-

.4-2.1 6.9 +-

.6-2.6 I

010 234 6.2 14.4 +-

.4 2.2 9.4 +-

.6 l 2.6 011 220 6.2 f11SS!tlG OR Ddl1 AGED DOSIt1ETER 012 213 6.9 13.1 +-

.4 '

2.0 8.3 +-

.6' 2.5 I

I 013 199 10.

13.0 +-

.4 l 2.0 8.2 +-

.5 2.5 I

014 190 10.

14.5 +-

.4 2.2 9.5 +-

.6 l 2.7 2.6 015 180 10.

15.4 +-

.5 ;

2.3 10.4 +-

.6 016 171 10.

14.9 +-

.4' 2.2 9.9 +-

.6' 2.7 017 165 9.0 14.2 +-

.4 l 2.1 9.3 +-

.6 2.6 I

I 018 203 16, 15.2 +-

.5' 2.3 10.2 +-

.6 2.7 I

I l

019 203 16, 14.3 +-

.4 2.1 9.4 +-

.6 2.6

.4 l' 2.0 I

l 020 203 16.

16.2 +-

.5 2.4 11.1 +-

.6

.6 l 2.8 021 268 8.7 13.3 +-

8.5 +-

2.5 022 256 8.0 111SSIllG OR DAllAGED LOS!!1ETER 023 275 9.0 tilSSIllG OR DAMAGED LOS!!!ETER 024 285 9.0 15.7 +-

.5 ;

2.4 10.7 +-

.6 '

2.8 I

025 293 8.7 17.1 +-

.5' 2.6 11.9 +-

.6 2.9 I

I 026 301 8.4 15.8 +-

.5 2.4 10.7 +-

.6 2.8 I

I 027 311 8.3 15.1 +-

.5 2.3 10.1 +-

.6 2.7 I

I 028 327 8.2 16.0 +-

.5l2.4 10.9 +-

.6 l 2.8 029 339 9.3 15.6 +-

.5 2.3 10.5 +-

.6 2.7 030 350 8.7 15.4 +-

.5 2.3 10.4 +-

.6 ;

2.7 I

031 359 9.9 15.8 +-

.5 2.4 10.7 +-

.6*

2.8 I

I 032 2/

18, 15.6 +-

.5 2.3 10.5 +-

.6 2.7 I

I 033 12/

21, 15.8 +-

.5 2.4 10.7 +-

.6 2.8 I

034 18/

24, 15.6 +-

.5 2.3 10.5 +-

.6 I 2.7 I

I 035 28/

22.

15.0 +-

.5 2.3 10.0 +-

.6 l 2.6 2.7

.4,l2.1 036 15 0.3 14.0 +-

.4 9.1 +-

.6 037 228 0.5 14.1 +-

2.1 9.2 +-

.6 ;

2.6 TRAlisti DOSE =

3.7

+-

.5 ; 2.0

127 TURKEY POINT FOR THE PERIOD 831214-840413 TLD DIRECT RADIATI0ll ENVIR0llMENTAL MONITORING RZIMUTH (deg.)

NET RVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qte.) t-Std.Dav.

340. 75-11.25 (N) 18.1 +- 1.8 4

11.25-33.75 (NNE) 19.1 +

.?

4 33.75-56.25 (NC)

NQ DRTR+-No DATR 8

54.25-78.75 (ENE)

NO DRTR+-N0 DATR 0

78.75-181.25 (E)

NO DATA +-NO DHTR 0

19L.25-123.75(ESC)

NO DATA +-N0 DATM 8

j 123.75-146.25(SC)

NO DRTR+-NO DATR G

145.25-IR5.75(SEC) 5.3 4- 0.5 1

q 155.75-151.25(5) 18.5 4-.1 3

151.25-213.75(55N) 8.34

.5 2

213.75-236.25 ( SN )

9.34-.2 2

4 236.25-258.75(WSW) 0.9 +- S.9 1

250.75-2st.25(W) s.5 +- e.a 1

28 t.25-393.75 (WNW) 19.5 +

.3 4

393.75-326.25(NH)

9. 5 +

. 5 3

i 326.25-348.75(NNN) 10.1 +- 1.0 3

i t

I i

OISTRNCC(mi) FROM THC REACTOR NET RVER.EXPOSUPE RATE

+ IN GROUP j

fnM/Etd,0tr.) +-5td.Dev.

B-2 9.8 +

.3 5

2-5 9.0 +- 8.0 1

1 55 10.0 +

.9 22 UPHIND CONTROL ORTA 19.2 +

.5 3

)

128 VERM0tli YAtlKEE TLD DIRECT RADIATI0tl El4VIR0llMEt1TAL N0tlITOR!flG FOR THE PERIOD 830930-840529 242 DAYS FIELD TIME 215 DAYS tlRC LOCATI0tl GROSS llET EXPO!VRE RATE STAT!0tl AZIt1VTH/DIST EXPOSURE (mR) rR/Std.0tr.

(deo.)

(mi.)

+- Pdm; Tot.

+- Rdm; Tot.

002 158 1

MISS!tlG OR DAMAGED DOSIMETER 003 184 1.3 51.5 +-

1.5 '

7. 7 16.6 +-

1.0

  • 4.5 004 201 1.4 53.3 +-

1.6 I 8.0 17.4 +-

1.0 l 4.6 005 220 1.6 49.9 +-

1.5 I 7.5 16.0 +-

1.0 4.5 1.0l;4.5 006 157 3.4 50.0 +-

1.5 I

7. 5 16.0 +-

1.5 ll 7.5 007 189 4.9 51.7 +-

1.5 7.7 16.7 +-

1.0 4.5 008 201 13, 50.1 +-

16.1 +-

1.0 4.5 1.0 *!

4.5 009 208 5.8 50.5 +-

1.5 7.6 16.2 +-

1.0 010 232 3.7 56.8 +-

1.7

  • 8.5 18.9 +-

4.8 1.7 ;l 8.4 1.0 ll 4.7 011 277 2.9 52.9 +-

1.6 7.9 17.2 +-

1.0 4.6 012 292 1.4 56.2 +-

18.6 +-

013 314 1.4 48.6 +-

1.5 15.4 +-

1.0 4.4 1.5 !'

7.3 1.0 *,

014 310 4.2 50.1 +-

7.5 16.1 +-

1.0 l 4.5 015 299 4.3 51.9 +-

1.6

  • 7.8 16.8 +-

4.5 016 270 4.5 MISS!tlGORDAllAGEDDOSIMETER 017 331 5

53.4 +-

1.6 '

8.0 17.5 +-

1.0 ;

4.6 018 290 18.

MISS!tlGORDAl1AGEDDOSIMETER 019 290 18.

HISSIllG OR DAMAGED DOS!t1ETER 020 290 18.

I1!S$ltlG OR DAllAGED DOS! HETER 021 359 3.2 42.7 +-

1.3 '

6.4 13.0 +-

.9' 4.1 023 334 2.2 49.2 +-

1.5 I I

7.4 15.7 +-

1.0 4.4 024 4

.9 51.8 +-

1.6 I 7.8 16.8 +-

1.0 4.5 I

025 30 1

47.7 +-

1.4 I I

7.2 15.1 +-

1.0 4.4 026 72 1.5 46.1 +-

1.4 I 1.0lI 6.9 14.4 +-

4.3 027 44

.7 52.1 +-

1.6 I 7.8 16.9 +-

1.0 4.6 028 39 2.8 HISSillGORDAllAGEDDOS! HETER 029 25 3.8 59.7 +-

1.8 '

8.9 20.1 +-

1.1 '

4.9 1

030 72 2.7 59.0 +-

1.8 I I

8.9 19.8 +-

1.1 4.9 I

I 031 85 2

54.2 +- 1.6 l 8.1 17.8 +-

1.0 4.6 I

032 111 1.8 50.9 +-

1.5 7.6 16.4 +-

1.0 4.5 033 134 4

49.7 +-

1.5 '

7.5 15.9 +-

1.0 I 4.4 034 151 6

47.9 +-

1.4 I I

7.2 15.1 +-

1.0 4.4 I

18.3 +-

1.0 I 035 111 4.3 55.5 +-

1. 7 l
8. 3 4.7 1.7 8.5 18.9 +-

1.0 I 036 92 4.7 56.9 +-

4.8 037 50 15 61.9 +-

1.9 '

9.3 21.0 +-

1.1 I 5.0 039 222

.3 60.0 +-

1.8 I 9.0 20.2 +-

1.1 4.9 I

040 250 3

53.6 +-

1.6 !

8.0 17.5 +-

1.0 !

4.6 TRAtlSIT DOSE =

!!.7

+-

1.8 ; 7.6 i

1 i

129 VERMONT YANKEE FOR THE PERIOD 830930-840529 TLD DIRECT RADIAT!0tl El1VIR0llMENTAL N0l11TORING MZIMUTH (deg.)

NET RVER. EXPOSURE RATE

+ IN GROUP (mR/Std.ote.)

+-S t d. De v.

348.75-14.25 (N) 14.9 += 2.7 2

j 11.25-33.75 (NNC) 17.5 +- 3.5 2

33.75-56.25 (NC) 26.9 +- 5.9 1

56.25-78.75 (CNC) 18.5 +- 3.0 1

78.75-101.25 (C) 18.3 +

.5 2

19 4.25-123.75 t CSC )

!?.4 +- 1.4 2

i 121.75-146.25 t SC )

15.5 +- 5.0 1

l i

145.25-155.75tS5C) 15.5 4

.5 2

160.73-151.25 t S )

15.7 4

.1 2

156.25-283.75t55W).

15.5 4

.7 3

i 213.75-23G.25 L SW) 19.3 4-2.2 2

i 23s.25-25e.75tusw) 17.5 +- e.e 1

25e.75-2et.25tW) 17.2 +- e.0 1

30 t.25-303.75 iHNW) 17.7 += 1.3 2

303.75-326.25 t NN )

15.8 +

.3 2

I 326.25-348.75tNNN) 16.5 += 1.2 2

I 4

j l

1

{

DISTANCCimt) FN0H THC PCACTOR NET RVCR.CMPOSURC RMTC

+ IN GROUP imR/std.Qte.) +-sid.Dav.

r i

B-2 17.8 += 1.5 it i

~

2-5 17.2 +- 4.0 15 I

55 17.1 +- 2.6 4

UPN!ND CONTROL DATA 15.7 +- 1.8 2

j J

l t

130 WASHillGT0tlllVCLEAR 2 TLD DIRECT RADIATI0tl EtiVIR0til1EllTAL 110ti! TOR!llG FOR THE PERIOD 831208-840413 127 DAYS FIELD TIME 88 DAYS NRC LOCAT!0tl GROSS tlET EXPO!VRE RATE STAT!0tl AZIMUTH /DIST EXPOSURE (mR) mR/St d.0t r.

(deg.)

(mi.)

23.4 +; Tot.

18.7 + ; Tot.

+- Rdm

+- Rdm 001 174 12,

.7 *I 3.5

.9'

.9 l 4.3 002 163 11.

22.0 +-

.7 3.3 17.2 +-

4.1 I

003 161 9.0 21.8 +-

.7 3.3 17.0 +-

.9*

4.1 I

I 004 152 5.0 23.8 +-

.7 3.6 19.1 +-

.9 4.3 005 195 2.0 22.8 +-

.7 I I

3.4 18.0 +-

.9 4.2 I

I 006 220 1.5 22.2 +-

.7 3.3 17.4 +-

.9 4.1 007 92 3.0 23.9 +-

.7 I

.9 I 3.6 19.2 +-

.9 l 4.4 I

008 155 1.0 22.4 +-

.7 3.4 17.6 +-

4.2 I

009 130 0.5 22.2 +-

.7 3.3 17.4 t-

.9 l 4.1 010 70 0.5 22.6 +-

.7 I 3.4 17.8 +-

.9 4.2 011 25 0.8 22.3 +-

.7 !

3.3 17.5 +-

.9*

4.1 I

012 315 0.5 23.0 +-

.7*

3.5 18.2 +-

.9 4.2 I

013 290 0.5 23.0 +-

.7 3.5 18.2 +-

.9 I 4.2 014 270 0.5 23.0 +-

.7 I I

3.4 18.2 +-

.9 4.2 015 245 1.8 22.2 +-

.7 I 3.3 17.4 +-

.9 I 4.1 I

016 285 3.0 24.9 +-

.7 3.7 20.1 +-

.9 I 4.5 017 240 4.0 22.1 +-

.7 I I

3.3 17.3 +-

.9 4.1 018 198 7.0 21.9 +-

.7 I 3.3 17.1 +-

.9 I 4.1 019 173 8.5 22.1 +-

.7 I 3.3 17.3 +-

.9 I 4.1 020 150 20.

23.2 +-

.7 I 3.5 18.4 +-

.9 I 4.3 021

!!4 7.0 24.2 +-

.7 I 3.6 19.5 +-

.9 I 4.4 I

022 120 8.0 21.5 +-

.6 3.2 16.7 +-

.8 !

4.0 I

023 134 6.0 24.8 +-

.7 3.7 20.1 +-

.9' 4.5 024 110 4.0 26.6 +-

.8 I 4.0 21.9 +-

1.0 I 4.7 025 85 5.0 23.3 +-

.7 I I

3.5 18.5 +-

.9 4.3 026 65

5. 0 24.7 +-

.7 I 3.7 19.9 +-

.9 I 4.5 027 53 4.0 22.6 +-

.7 !

3.4 17.8 +-

.9 I 4.2 I

028 44 8.0 23.7 +-

.7*

3.5 18.9 +-

.9 l 4.2 4.3 I

029 33 10.

22.5 +-

.7 3.4 17.7 +-

.9 I

030 8

9.5 24.4 +-

.7 l 3.4 3.7 19.7 +-

.9*

4.4

.7 18.0 +-

.9 l 4.2 031 215 15.

22.8 +-

TRAtlSIT DOSE =

5.2

+-

.5 ; 2.3

1 131 WASHINGTON NUCLEAR 2 FOR THE PERIOD 831208-840413 TLD DIRECT RADIAT!0H ENVIRONMENTAL M0HITORING RZINUTH (dog.)

NCT RYER. EXPOSURC RATC 4 IN GROUP (mR/Std.Qtr.) t-Std.Dav.

l 348.75-il.35 (N) 19.7 +- E.8 1

I 11.25-33.75 (NNC) 17.5 +

.1 2

33.75-56.25 (NC) 10.3 +

.I 2

36.25-78.75 (CNC) 18.5 +- 1.5 2

10. 7 5-181. 25 ( b~ ~~ ~ ~

~

10.8 4-

.5 2

18 L. 25-12 3. 75 ( C BC )

19.4 +- 2.6 3

t 123.75-144.25(SC) 18.7 +- 1.9 2

145.25-155.75(55C) 17.8 4

.5 5

1 150.75-151.25(5) 17.3 4-5.5 1

151.25-213.75(55N) 17.5 4

.7 2

4 I

213.75-236.25(SW) 17.4 4-5.0 1

236.25-250.75(W5W) 17.3 +>.1 2

254.75-201.25(W) 10.2 +- E.9 1

201.25-303. 75 ( WNW 1 15.2 += 1.3 2

j 303.75-326.25(NN) 18.2 +- 5.0 1

1 326.25-340.75(NNN)

NO DRTAt-N0 DATA 0

j t

l i

i I

016TMNCC(me1 FM0H THC PEACTOP NET RVEM.CMPO6UPC PATC

+ IN r. Rote imM/5td10tr.) +-Sid.Deo 0-2 17.I +

.4 la l

l I-5 19.I += 1.5 8

>5 10.1 +- 1 2 11 4

UPHIND CONTROL DRTA 18.3 +

.5 2

132 WATERFORD TLD DIRECT RADIAT!0ll EllVIR0tiMEllTAL M0ll!TORIllG FOR THE PERIOD 831208-840412 126 DAYS FIELD TIME 91 DAYS llRC LOCAT!0ll CROSS IIET EXP0EURE RATE STATI0tl AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

(deg.)

(mi.)

+- Rdm; Tot.

10.2 + ; Tot.

+- Rom 001 101 0.4 19.1 +-

.6 ;

2.9

.8 j 4.0 002 116 1.1 18.2 +-

.5 ;

2.7 9.3 +-

.8 3.9 003 132 1.3 19.9 +-

.6

  • 3.0 11.0 +-

.9 I 4.1

.5 l 2.5

.5 2.6 8.2 +-

.8 I 004 160 1.8 17.1 +-

3.8 I

005 183 1.4 16.8 +-

7.9 +-

.8 3.7 006 202 1.2 17.8 +-

.5 2.7 8.9 +-

.8 l 3.8 I

007 226 1.2 17.1 +-

.5 1 2.6 8.2 +-

.8' 3.8 008 248 1.3 20.6 +-

.6 I 3.1 11.7 +-

.9 l 4.1 009 265 1.0 MIS 0111G OR DAllAGED DOS! METER 010 186 4.2 19.8 +-

.6' 3.0 10.8 +-

.8' 4.1 011 315 4.4 19.0 +-

.6 I

.8 l 4.0 2.8 10.0 +-

.8 4.0 012 328 4.1 19.3 +-

.6 I 2.9 10.3 +-

.8l I

013 309 0.8 19.7 +-

.6 3.0 10.8 +-

4.0 I

I 014 273 0.9 21.7 +-

.6 3.2 12.7 +-

.9 4.3 015 292 0.8 20.3 +-

.6 I 3.0 11.3 +-

.9 I 4.1 I

.8lI 016 335 0.5 17.0 +-

.5 2.6 8.1 +-

3.8 I

017 120 4.3 16.1 +-

.5 2.4 7.2 +-

.8 3.7 1

018 145 3.5 MISSIllGORDAl1AGEDDOSIMETER j

019 153 8.1 17.7 +-

.5*

2.7 8.8 +-

.8 3.8 020 133 8.1 18.4 +-

.6 2.8 9.4 +-

.8 ';

3.9 I

1 021 116 6.7 18.7 +-

.6 I I

2.8 9.8 +-

.8 3.9 022 95 4.3 17.6 +-

.5 I 2.6 8.7 +-

.8 I 3.8 I

023 86 2.6 17.6 +-

.5 2.6 8.7 +-

.8 !

3.8 024 66 4.2 20.1 F-

.6 I 3.0

!!.2 +-

.9*

4.1 025 37 3.5 18.1 +-

.5 l 2.7 9.2 +-

.8 I 3.9 I

026 23 3.8 16.1 +-

.5*

2.4 7.2 +-

.8 3.7

.5 l 2.7 027 350 4.9 17.3 +-

.5 2.6 8.4 +-

.8 3.8 I

028 335 5.0 17.8 +-

8.9 +-

.8 3.8 029 6

2.8 16.5 +-

.5 I 2.5 7.6 +-

.8 I 3.7 030 356 1.1 17.4 +-

.5 I 2.6 8.5 +-

.8 l 3.8 031 15 0.8 18.9 +-

.6 I 2.3 10.0 +-

.8

  • 4.0 i

032 40 0.8 16.9 +-

.5 I 2.5 8.0 +-

.8 !

3.8 l

033 69 1.1 22.3 +-

.7 I 3.3 13.4 +-

.9' 4.3 I

l 034 292 15.

17.6 +-

.5 2.6 8.7 +-

.8 I 3.8 035 282 27.

21.1 +-

.6 !

3.2 12.1 +-

.9lI 4.2 036 268 21, 18.2 +-

.5 ;

2.7 9.3 +-

.8 3.4 TRAIISIT DOSE 8.8

+-

.6 ; 2.0 i

I l

[

133 WATERFORD FOR THE PERIOD 831208-840412 TLD DIRECT RADIATION EllVIRONMENTAL MONITORING RZIMUTH (deg.)

NET AVER. EXPOSURE RATC 4 IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-IL.25 (N) 0.1 +

.5 3

11.25-33.75 (NNC) 8.6 +- 2.9 2

t l

33.75-58.25 (NC) 9.6 +

.O 2

St.25-78.75 (CNE) 12.3 +- 1.5 2

l 14.75-10L.25 (C) 9.2 +

.9 3

tel.25-123.75(CBC) 8.7 +- 1.4 3

i 123.75-146.25(SC) 19.I +- 1.1 2

145.25-150.75(55C) 5.5 4

.5 2

1 155.75-191.25(5) 5.4 4-2.1 2

191.25-2L3.75(55N) 5.5 4-4.5 1

I 213.75-236.25(SW) 0.2 4-6.8 1

338.25-250.75(W5H1 11.7 +- 0.9 1

1 250.75-201.25(W) 12.7 +- 5.0 1

j 20 8.25-393. 75 ( WNW) 11.3 += 5.9 1

t 193.75-326.25(NN) 10.4 +

.5 2

326.25-348.75(NNN) 9.1 +- 1.1 3

I i

j i

i i

0]STMNCCimt) TROM THC PCACTOR NET RVER.CXPOSUPE PMTC

+ 1N GMOUP (mN/5td.Qte.) +-5td.Dav.

8-2 9.9 +- 1.5 15 1

l t-5 9.0 4-1.4 II 85 9.4 +

.5 3

UPH!ND CONTROL ORTA 10.9 +- 1.9 3

t f

i 1

134 WATTS PAR TLD DIRECT RADIATI0tl EllVIR0llMEllTAL M0tlITORIflG FOR ThE PERIOD 831214-840427 135 DAYS FIELD TIME 105 DAYS llRC LOCATI0ll GROSS flET EXPOSURE RATE STAT!0ft AZIMUTH /DIST EXPGSURE(mR) mR/Std.0tr.

(deo.)

(mi.)

+- Rdm

+- Rdm 21.8 +; Tot.

15.7 + ; Tot.

001 337 0.9

.7 3.3

.7 3.3 002 314 2.1 22.4 +-

.7 ';

.7 ;

3.4 16.2 +-

3.3

.7 ;;

003 297 1.9 21.6 +-

.6 !

3.2 15.5 +-

3.2 004 272 2.0 21.2 +-

.6 3.2 15.2 +-

.7 j 3.2 005 251 1.9 23.1 +-

.7 ;

3.5 16.8 +-

.7, 3.4 006 235 1.8 25.1 +-

.8 ;

3.8 18.5 +-

.8 3.6

.7 ;;

I 007 230 3.8 23.4 +-

.7 3.5 17.1 +-

3.4

.7 l 2.9 008 208 3.6 22.0 +-

3.3 15.9 +-

.7 3.3

.6 13.9 +-

.6 ;

009 249 4.2 19.7 +-

3.0

.6 ;;

3.2 15.1 +-

.7 ;

010 266 3.1 21.1 +-

3.2

.5 2.7 12.6 +-

.6 ;

011 289 3.3 18.2 +-

.6 ;

.6 ;

2.9 012 310 4.7 18.9 +-

2.8 13.2 +-

2.9

.6 ;;

013 337 3.6 18.8 +-

2.8 13.2 +-

.6 ;

2.9 014 330 7.0 19.9 +-

.6' 3.0 14.1 +-

.6 3.0

.7 17.1 +-

.7 ;

.7 l 3.5 015 350 4.7 23.5 +-

3.4

.7 ;

016 7

1.1 23.0 +-

3.4 16.7 +-

.5 ;

.6 ;

3.4 017 23 1.6 18.1 +-

2.7 12.5 +-

2.9

.6 ;;

.6 ;;

018 41 2.3 19.9 +-

3.0 14.1 +-

3.0 019 69 1.3 22.2 +-

.7 3.3 16.1 +-

.8 ;

.7 3.3

.8 ;;

020 89 1.2 25.1 +-

3.8 18.5 +-

3.6 I

021 114 1.1 19.8 +-

.6 3.0 14.0 +-

.6

.7 l' 3.0 I

022 141 1.0 24.4 +-

.7 3.7 18.0 +-

3.5 023 163 1.1 26.2 +-

.8 I 3.9 19.5 +-

.8 3.7

.7 ;;

1 024 187 1.1 20.4 +-

.6 3.1 14.5 +-

3.1 I

025 203 1.2 23.0 +-

.7 3.4 16.7 +-

.7 ;

3.4 026 184 5.9 NISSIllG OR DAl1 AGED DOSINETER 027 176 4.5 20.8 +-

.6 3.1 14.8 +-

.7' 3.1

.6 ';

I 028 161 3.5 20.,. +-

3.0 14.4 +-

.6 3.1 3

.7 l 3.1 029 144 3.0 20.7 +-

.6 3.1 14.8 +-

3.1 030 117 3.1 20.5 +-

.6 l 3.1 14.6 +-

.7-031 97 4.0 20.4 +-

.6 ;

3.1 14.5 +-

.7 !

3.1 032 76 4.1 17.9 +-

.5 ;

2.7 12.3 +-

.6 ;

2.8 033 32 4.1 22.3 +-

.7 3.3 16.2 +-

.7' 3.3 034 36 4.7 18.9 +-

.6 ;

2.3 13.2 +-

.6 !

2.9

.6 ;

035 338 18.

19.7 +-

2.9 13.9 +-

.6 *;

.6 3.0 13.1 +-

.6 ;

036 338 18.

18.7 +-

.7 l 2.3 2.9 3.3 15.9 +-

.7 !

3.3 037 338 18.

22.1 +-

TRAllsli DOSE =

3.5

+-

.5 ; 1.9 i

l l

l

135 HATTS BAR FOR THE PERIOD 831214-840427 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH ( dog. )

NET AYER. EXPOSURE RATE

+ IN GROUP (mR/Std.Qir.) t-Std.Dav.

348.75-il.25 (N) 16.9 +

.3 2

11.25-33.75 (NNE) 14.3 +- 2.6 2

33.75-56.25 (NE) 13.7 +

.6 2

56.25-78.75 (ENE) 14.2 +- 2.6 2

78.75-101.25 (E) 16.5 +- 2.8 2

101.25-123.75(ESE) 14.3 +

.4 2

123.75-146.25(SE) 16.4 +- 2.2 2

146.25-160.75(55E) 16.9 +- 3.6 2

160.75-191.25(5) 14.7 +

.2 2

19L.25-213.75(55H) 16.3 4-.5 2

213.75-236.25(SH) 17.8 +- 1.0 2

236.25-250.75(H5H) 15.4 +- 2.!

2 250.75-201.25(H) 15.1 +

.1 2

20L.25-303.75(HHH) 14.1 +- 2.0 2

303.75-326.25(NH) 14.7 +- 2.2 2

~

326,25-34e.75(NNN) 14.3 +- 1.3 3

DISTANCE (mt) FROM THE REACTOR NET RVER. EXPOSURE PATE 4 IN GROUP (nF/5td.0tr.) +-5td.Dev.

B-2 16.3 +- 1.9 14 2-5 14.6 +- 1.4 1B 55 14.1 +- 0.0 1

UPHIND CONTROL ORTA 14.3 +- 1.5 3

l k

1 1

136 WOLF CR.

TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831209-840411 124 DAYS j

FIELD TIME 90 DAYS 1

a NRC LOCATION GROSS HET EXPOSURE RATE j

STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

1 (deg.)

(mi.)

22.6 +; Tot.

16.8 + ; Tot.

+- Rdm

+- Rdm

.7 ;

3.4

.9 ;

4.1 j

001.

316 2.9 002 330 1.8 21.7 +-

.6 3.2 15.9 +-

.8 4.0

.6 ;;

.8 ;;

003 360 2.8

.21.1 +-

3.2 15.4 +-

3.9 004 355 1.6 24.2 +-

.7 3.6 18.5'+-

.9 4.3

.7 ;

.9 ;

005 031 1.8 23.1 +-

3.5 17.3 +-

4.2

.7-;; '3.3

.9 ;;

006 047 2

22.3 +-

16.5 + -

4.1 007 70 1.6 22.9 +-

.7 ;

3.4 17.1 +-

.9 4.1

.9 ;;

008 90 1.7 23.9 +-

. 7..

3.6 18.2 +--

4.' 3 '

.7 ;

3.6 009 111 2.4 24.3 +-

18.5 +-

.9 4.3

.8 ;;

3.8

.9 ;

010 137 2.5 25.4 +-

19.7 +-

4.5

.9 ;

011 157 3.4 24.7 +-

.7 ;

3.7 18.9 +-

4.4

.9 ;

012 184 3.3 24.4 +-

.7 3.7 18.6 +-

4.3

.7 ;

.9 ;

013 213 2.9 23.7 +-

3.6 18.0 +--

4.2

.7 ;

.9 ;

014 233 2.4 23.8 +-

3.6 18.1 +-

4.3

.7 ;;

.9 ;;

015 248 2.2 23.4 +-

3.5 17.6 +-

4.2 016 278 2.1 24.6 +-

.7 ;

3.7 18.9 +-

.9 ;

4.4 017 270 3.4 19.6 +-

.6 2.9 13.9 +-

.8 3.7 018 263

4. 2 ~

25.9 +-

.8 ;

.9 ;;

3.9 20.1 +-

4.5 020 280 3.9 22.7 +--

.7 ;

3.4 17.0 +-

.9 ;

4.1

.7 ;

021 298 3.9 24.8 +-

3.7 19.0 +-

.9 4.4 022 319 4.8 22.5 +-

.7 ;

.9 ;

3.4 16.7 +-

4.1

.7 ;;

.9 ;

023 332 5

23.2 +-

3.5 17.4-+-

4.2

.9 ;

024 019 3.9 23.4 +-

.7 ;

3.5 17.7 +-

4.2

.9 ;;

025 35 4.4 22.2 +-

.7 ;

3.3 16.4 +-

4.1 026 67 4.3 21.9 +-

.7 3.3 16.2 +-

.8 4.0 027 88 4.1 24.7 +-

.7 ;

.9 ;

3.7 18.9 +-

4.4

.7 ;

.9 ;

028 110 4.5 24.3 +-

3.6 18.5 +-

4.3 029 128 4.4 24.6 +-

.7 ;

.9 ;;

3.7 18.8 +-

4.4 030 112 16.

21.8 +-

.7 ;

3.3 16.0 +-

.8 ;

4.0

.6 ;

031 127 9.4 21.1 +-

3.2 15.4 +-

.8 ;

3.9 032 162 22.0 +-

.7 ;

~3' 3.3 16.3 +-

.8 4.0

.7 ;;

.9 ;;

333 153 5.2 23.5 +-

3.5 17.7 +-

4.2 034 174 4.7 23.3 +-

.7 3.5 11.5 +-

.9 ;

4.2 035 197 5.2 22.9 +-

.7 ;

3.4 17.1 +-

.9 ;

4.1

.7 ;

036 224 4.8 22.1 +-

3.3 16.4 +-

.9 4.0

.6 ';

.8 ;;

037

-220 14.

20.0 +-

3.0 14.3 +-

3.8 038 253 6.5 MISSING OR DAllAGED DOSIMETER 039 278 10.

23.3 +-

.7 3.5 17.6 +-

.9 ;

4.2

.6 ;

040 285 15.

20.4 +-

3.1 14.6 +-

.8 3.8

.7 ;

.9 ;

041 292 6.7 22.9 +-

3.4 17.2 +-

C1 042 345 13' 23.3 +-

.7 ;

.9 ;;

3.5 17 5 +-

4.2

.7 ;

'043 005 7.5 23.4 +-

3.5 17.7 +-

.9 ;

4.2 044 020 8.3 MISSINGORDAllAGEDDOSIMETER 045 315 7.5 24.4 +-

.7 3.7 18.7 +-

.9 ;

4.3

.7 ;

046-341 7.7 23.9 +-

3.6 18.2 +-

.9 ;

4.3

.6 ;;

047 355 1

21.4 +-

3.2 15.6 +-

.8- ;

4.0 TRANSIT DOSE =

5.7

+-

.5 ; 2.3 4

13<

l-10LF CR.

FOR THE PERIOD 831209-840411 TLD DIRECT RADI ATION EN'/IRONMENTAL MONITORING RZIMUTH (dag. )

NET AVER. EXPOSURE RATE

  • IN GROUP (mR/Std.Qir.) t-Std.Dev.

348.75-ll.25 (N) 16.8 +- 1.5 4

7-11.25-33.75 (NNE) 17.5 +

.2 2

33.75-56.25 (NE) 16.5 +

.1 2

I 56.25-78.75 (ENE) 16.6 +

.7 2

78.75-10l.25 (E) 18.5 +

.5 2

101.25-123.75(ESE) 17.7 +- 1.4 3

123.75-146.25(SE) 17.9 +- 2.3 3

14 5.25-158.75 ( 55 E )

17.5 4-1.3 3

158.75-191.25(5) 18.1 4-

.8 2

191.25-2l3.75(55H) 17.5 +

.5 2

213.75-236.25(SFD 1G.2 4-1.9 3

238.25-258. 75 ( W 554 )

17.B +- 0.0 1

258.75-201.25(W) 17.5 +- 2.4 5

28 l.25-303.75 (llNH) 18.9 +- 2.2 3

303.75-326.25(NN) 17.4 +- 1.1 3

326.25-348.75(NNN) 17.2 +- 1.0 4

DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/5td,0tr.) +-5td.Dev.

0-2 17.0 +- 1.1 7

2-5 17.7 +- 1.4 24

~

>5 IS.8 +- 1.4 13 UPHIND CONTROL DRTA NO DATA NO DATA

\\

,, _ r

138 YANKEE R0WE TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831216-840420 126 DAYS FIELD TIME 98 DAYS HRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/St d.Qt r.

(deg~. )

(mi.)

+- Rdm; Tot.

+- Rdm; Tot.

001 0

.8 23.9 +-

.7 ;

3.6 NO NET'DfiTA 005 85 2.2 18.9 +-

.6 l 2.8 NO NET Df!TA 006 118 2.6 19.8 +-

.6 ;

3.0 110 NET DATA 007 137 2.1 20.7 +-

.6 ;

3.1 t10 NET DATA 008 153 1.7 20.1 +-

.6 ;

3.0 t10 NET DATA 009 176 1.1 19.1 +-

.6 2.9 N0 NET DATA

.6 ;;

010 203

.5 19.2 +-

2.9 N0 tiET DATA 011 219

.6 19.5 +-

.6 2.9 N0 NET DflTA

.7 ;;

012 239 1.1 24.1 +-

3.6 NO NET DflTA 013 272 1.8 MISSIllG OR DAMAGED DOSIMETER 014 292 1.3 MISSING OR DAMAGED DOSIMETER 015 315 1.6 20.7 +-

.6 ;

3.1 NO NET DfiTA 016 348 1.4 20.5 +-

.6 ;

3.1 t10 t1ET DfiTA 017 358 2.8 18.4 +-

.6 ;

2.8 N0 t1ET Df!TA 018 21 2.8 18.5 +-

.6 ;

2.8 NO NET DflTA 019 43 5.8 19.4 +-

.6' 2.9 N0 f1ET DATA

.6 ;

020 75 6

19.8 +-

3.0 N0 flET Df!TA 021 98 6

19.4 +-

.6 ;

2.9 N0 f1ET DATA

.5 ;

022 104 5.2 17.7 +-

2.7 NO NET DfiTA 023 133 5.7 MISSING OR DAMAGED DOSIMETER 024 157 7.5 18.3 +-

.5 ;

2.7 fl0 NET Df!TA 025 184 6.3 18.8 +-

.6 ;

2.8 fl0 NET Df;TA 027 225 5.9 20.2 +~

.6 ;

3.0 NO NET DfiTA 029 269 3.5 20.5 +-

.6 ;~

3.1 NO NET DATA 032 342 3.3 20.1 +-

.6 i 3.0 NO NET DATA 034 48 7.3 20.7 +-

.6 ;

3.1 NO NET DflTA 035 39 2.3 18.4 +-

.6 ;

2.8 t10 NET DATA 047 260 9.6 21.4 +-

.6 ;

3.2 N0 NET DATA 048 261 9

22.3 +-

.7 ;

3.3 h0 NET Df!TA t10 TRAt1 SIT DOSE CALCULATED (TLD C011TROLS~ MISSING OR OTHERHISE NOT COMPLETE)

.A

r yJg rii l

,g, l

mi an

,n upng gie-vi

,inipi=i o-4-

f iq in-isy pqq n.:

i g-

,i'rg p

sq

,u i

g ni n,q;i,-

139 YANKEE R0WE FOR THE PERIOD 831216-840420 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dag.)

RVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dev.

348.75-ll.25 (N) 15.1 +- 2.8 2

11.25-33.75 (NNE) 13.2 +- D.O 1

33.75-56.25 (NE) 13.9 +

.8 3

56.25-78.75 (ENE) 14.1 +- 0.0 1

78.75-101.25 (E) 13.7 +

.3 2

1 10l.25-123.75(ESE) 13.4 +- 1.1 2

i 123.75-146.25(SE) 14.8 +- 0.0 1

145.25-158.75 ( 55 E )

13.7 +

.9 2

158.75-191.25(5) 13.5 +

.1 2

191.25-213.75 ( 55H ]

13.7 4-B.O 1

213.75-236.25(SW) 14.2 +

.4 2

236.25-258.75(u5u) 17.2 +- 0.0 1

258.75-281.25(W) 14.6 +- 0.0 1

28L.25-303.75(WNW)

NO DRTRt-NO DATR 0

303.75-328.25(NH) 14.8 +- 0.0 1

326.25-348.75sNNH) 14.5 +

.2 2

r DISTANCE (mi) FROM THE REACTOR RVER. EXPOSURE RATE

+ IN GROUP (mR/5td 0tr.) +-5td.Dev.

B-2 14.9 +- 1.4 8

2-5 13.9 +

.7 8

>5 13.8 +

.7 8

UPNIND CONTROL ORTA 15.8 +

.5 2

r i-

140 ZfMMER TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 831209-840413 126 DAYS FIELD TIME 71 DAYS i

NRC LOCATION-GROSS NET EXPOSURE RATE STATION ' AZIMUTH /DIST' EXPOSURE (mR) mR/St d. Qt r.

(dea.)

(mi.)

+- Rdm; Tot.

15.4 + ;T6t.

+- Rdm 001 182 0.4 24.0 +-'

.7 ;

3.6 1.2 ;

5.9 002 150 1.0 26.4 +-

.8 4.0 18.4 +-

1.3 ;

6.3

.8 ;

003 133 1.1 27.5.+-

4.1 19.8 +-

1.3 1 6.4 004 106 2.1 28.2 4-

.8 ;;

4.2 20.7 +-

1.3 ;

6.5 005 82 2.9 25.3 +-

.8 ;

3.8 17.1 +-

1.2 6.1 16.2 +- -1.2 ;;

006 091 4.4 24.6 +-

.7 ;

3.7 6.0 007 106 7.3 24.2 +-

.7 ;

3.6 15.7 +-

1.2 ;

5.9' 008 135 6.6 27.1 +-

.8 ;

4.1 19.4 +-

1.3 ;

6.4 009 163 4.2 27.8 +-

.8 4.2 20.2 +-

1.3 ;

6.5 010 129 3.9 25.5 +-

.8 ;

3.8 17.3 +-

1. 3 - ;

6.' 1 011 115 4.6 MISSINGORDAllAGEDDOSIMETER 012 74 3.9 26.1 +-

.8 ;

3.9 18.1 +-

1.3 ;

6.2 013 50 3.6 26.8 +-

.8 ;

4.0 19.0-+-

1.3 ;

6.3 014 22 4.1-

~25.1 +-

.8 ;

3.8 16.8 +-

1.2 6.1 1.2 ;

015 354 3.7 24'.8 +-

.7 l 3.7 16.5 +-

6.0 016 359 2.1 MISSING OR DAMAGED DOSIMETER 017 26 2.0 28.3 +-

.8 ;

4.2 20.9 +-

1.3 ;

6.6 018 47 1.6 26.6 +-

.8 ;

4.0 18.7 +-

1.3 :

6.3 019 72 0.8 25.9 +-

.8 ;

3.9 17.9 +-

1.3 6.2 020 335 7.3 27.2 +-

.8 ;

4.1 19.5 +-

1.3 ;

6.4 021 332 4.0 23.5 +-

.7 ;

3,5 14.8 +-

1.2 ;

5.8 1.3 ;;

022 335 1.8 26.9 +-

.8 ;

4.0 19.1 +-

6.3 023 310 2.1 26.1 +-

.8 ;

3.9 18.1 +-

1.3 ;

6.2 024 286 1.9 25.1 +-

.8 ;

3.8 16.9 +-

1.2 ;

6,1 025 276 1.4 MISSING OR DAMAGED DOSIMETER 026 247 0.9 26.5 +-

.8 ;

4.0 18.6 +-

1.3 ;

6.3 027 218 1.1 25.3 +-

.8 ;

3.8 17.1 +-

1.2 ;

6.1 028 200 1.9 26.1 +-

.8 l 3.9 18.1 +-

1.3 ;

6.2 029 191 4.5 25.2 +-

.8 i 3.8 17.0 +-

1.2l 6.1 030 212 4.4 26 2 +-

.8 ;

3.9 18.2 +-

1.3 ;

6.2 031 229 4.1 26.9 +-

.8 ;

4.0 19.1 +-

1.3 ;

6.3 032 248 3.5 26.2 +-

.8 ;

3.9 18.3 +-

1.3 ;

6.3 033 270 3.7 25.3 +-

.8 ;

3.8 17.1 +-

1.2 ;

6.1 034 292 4.5 25.4 +-

.8 ;

3.8 17.2 +-

1.3 ;

6.1 035 317 4.6 26.3 +-

.8 ;

3.9 18.4 +-

1.3 ;

6.3 036 106 19.

24.3 +-

.7 ;

3.6 15.8 +-

1.2 ;

6.0 037 107 20.

26.4 +-

.8 l 4.0 18.4 +-

1.3 ;

6.3 038 107 20.

26.1 +-

.8~;

3.9 18.1 +-

1.3 ;

6.2 TRANSIT DOSE =

11.8

+-

.6 ; 3.0

141 ZIMMER FOR THE PERIOD 831209-840413

-=

TLD DIRECT RADIfiTION ENVIRONMENTAL MONITORING RZIMUTH (dag.)

tJET RVER. EXPOSURE RATE

+ IN GROUP g

(mR/Std.Qtr.) t-Std.Dev.

i

[

348.75-ll.25 (N) 16.5 +- 0.0 1

11.25-33.75 (NNE) 18.9 +- 2.9 2

33.75-56.25

( tJ E )

18.9 +

.2 2

a 56.25-78.75 (ENE) 18.0 +

.2 2

(

78.75-10l.25 (E) 16.6 +

.6 2

E 10l.25-123.75(ESE) 18.2 +- 3.6 2

E 123.75-146.25(SE) 18.8 +- 1.4 3

F-14 6.25-168. 75 ( 55E )

19.3 4-1.3 2

168.75-191.25(5) 16.2 4-1.1 2

y 19L.25-2L3.75(SSN) 18.1 +

.1 2

=

213. 75 -236.25 (SW) 10.1 +- 1.4 2

{

238. 2 5-258.75 ( L1564 )

18.4 +-.3 2

258.75-281.25(l4) 17.1 +- B.O 1

I 28 l. 2 5-303.75 ( LANnU 17.1 +

.3 2

E 303.75-328.25(NN) 18.2 +-.2 2

h 326.25-348.75(NNN) 17.B +- 2.6 3

b E

BiE r

L E

DISTANCE (mi) FRON THE REACTOR NET RVER. EXPOSURE RATE

+ IN GROUP

?-

( mR/Std. Qt r. ) +-5td.Dev.

5 0-2 18.3 +- 1.5 11 y_

2-5 17.8 +- 1.4 18 C

>5 18.2 +- 2.2 3

UPHIND CONTROL DATR 17.4 +- 1.4 3

b e

a 142 1 ZION TLD DIRECT RADIATION ENVIRONMENTAL MONITORING i

FOR THE PERIOD.831209-840407-120 DAYS

~ FIELD-TIME 87-DAYS HRC LOCATION GROSS NET EXPOSURE RATE i

STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.

i (dea.)' (mi.)

+- Rdm; Tot.

+- Rdm; Tot.

1 001.

287 1.0 MISSING OR DAMAGED DOSIMETER i

.5 2.4 11.6 +-

.7 ;

3.4 1

002 192 1.0 15.9 + -

.6 ;

2.8 14.6 +-

.8 ;

3.7 003 187 1.5 18.8 +-

.6 ;

3.0 15.8-+-

.8 ;

3.9 004 227 2.4-20.0 +-

.6 ;

3.2 17.0 +-

.8 ;

4.0 005 257 1.8 21.1 +-

.6 ;

3.1 16.8 +-

.8 ;

4.0 006 264 1.2 20.9 +-

.6 ;;

.8 3.9 3.0 16.1 +-

007 287 1.6 20.2 +-

. 8 ;;

3.7 008 320 1.8 18.5 +-

.6 ;- 2.8 14.3 +-

.6 2.8 14.6 +-

.8 ;

3.7 009 343 2.6 18.8 +-

.6 ;

2.8 14.2 +-

.8 ;

3.7 010 356 4.5 18.4 +-

.6 ;

2.9 15.4 +--

.8 ;

3.8 011 337 4.5 19.5 +-

.6 ;

3.1 16.6 +-

.8 ;

4.0 012 310 4.0 20.7 +-

.7';

3.3 17.8 +-

.9 ;

4.1 013 293 3.5 21.9 +-

.7 ;

3.3 17.8 +-

.9 ;

4.1 014 280 4.5 21.9 +-

.6 ;

3.1 16.4 +--

.8 3.9 015 239 3.2 20.6 +-

.6 ;

17.4 +-

.9.;

4.1 3.2 016 227 3.5 21.5 +-

.8 ;

.5 ;

2.7 14.1 +-

3.7 017 210 4.5 18.3 +-

.6 ;

.8 ;

3.8 2.9 15.0 +-

018 206 2.8 19.2 +-

.8 ;

3.8

.6 ;;

2.9 15.3-+-

019 342 2.7 19.4 +-

.9 ;;

4.2 020 197 14.

22.5 +-

.7 ;

3.4 18.5 +-

021 352 7.9 16.5 +-

.5 ;

2.5 12.3 +-

.7 ;

3.4 022 348 8.3 17.9 +-

.5 ;

2.7 13.6 +-

.8 ;

3.6 023 336 8.5 19.3 +-

.6 ;

2.9 15.1 +-

.8 ;

3.8 024 314 5.8 18.9 +-

.6 ;

2.8 14.7 +-

.8 ;

3.7

.6 3.0 16.1 +-

.8 ;

3.9 025 220 6.3 20.3 +-

.6 ;;

2.8 14.4 +-

.8 3.7 026 195 8.0 18.6 +-

.9 ;

028 197 14.

21.8 +-

.7 ;

3.3 17.7 +-

4.1

.9 ;

.6 3.2 17.4 +-

4.0 030 320 9.8 21.5 +-

.6 ;

.8 ;

TRANSIT DOSE = 4.7 +-

.5 ; 2.2

~

3.0 15.6 +-

3.8 031 229 8.0 19.8 +-

4

(

l l

I L

r_ _ _

l 143

. ZION FOR THE PERIOD 831209-840407 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dag.)

NET RVER. EXPOSURE RATE

$ IN GROUP (mR/Std.Qtr.) t-Std.Dav.

348.75-11.25 (N) 13.2 +- 1.4 2

11.25-33.75 (NNE)

NO DATA +-NO DATA 0

33.75-56.25 (NE)

NO DRTR+-NO DATR 0

56.25-78.75 (ENE)

NO DRTR+-NO DATR 0

78.75-10l.25 (E)

NO DRTA+-NO DATR 0

10l.25-123.75(ESE)

NO DATA +-NO DATR 0

123. 75,- 146. 25 ( S E )

NO DATA +-NO DATR 0

146.25-168.75(55E)

NO DRTR&-NO DRTR 8

158.75-191.25(5) 14.5 +- B.O 1

19L.25-213.75(55H) 13.8 +- 1.5 4

213.75-236.25(SW) 16.2 +

.8 4

236.25-258.75(HSW) 16.7 +

.4 2

258.75-281.25(H) 17.3 +

.7 2

28l.25-303.75(HNH) 17.B +- 1.2 2

303.75-328.25(NH) 15.B t-1.5 4

326.25-348.75(NNN) 14.B +

.7 5

DISTANCE (mi) FROM THE RE; ACTOR NET RVER. EXPOSURE RATE

+ IN GROUP (mR/5td.Qtr.) +-Std.Dev.

B-2 15.1 +- 2.0 6

2-5 15.9 +- 1.3 12

>5 14.9 +- 1.6 8

UPHIND CONTROL DRTA 18.1 +

.5 2

NRC PORM 335 U S. NUCLEJM k E LULATOR Y COesM,58 TON i WEPOMY NUMSE A 1 Ass pand err /DC..et Fm pl. <f.aFI h"o2d2'

o. 1 BIBLIOGRAPHIC DATA SHEET

$EE INSTINCT 40NS ON THE REVEgE

2. TITLE ANo SUBTITLE J LE AVE BLANK NRC TLD Direct Ra iation Monitoring Network j

i r

-Progress Report-

/""'*""'-

Januarv-March 1984

" " /

l October f 1984

._ AUT o

<s, F. Costello, M. Kramari, L. Cohen I'^""""""'

Octo 1984 7 WE*f onMING ORGANIZA1 BON NAME ANo MAILING A RE SS (fac%se le C.*/

8 PROP / TASK. WORK UNIT NUMBER Region I J

.U. S. Nuclear Regulatory Co ission a poa ca*N' N-aa King of Prussia, PA 19406 J

io s.mso.s No oasANu ATioN,iAME ANo M A. Lino Aoo Ess u,,,s e, C,

7

.. Tv,E o, aE, oar Region I "f

Quarterly Report U. S. Nuclear Regulatory Commission King of Prussia, PA 19406 8

f January-March 1984

.2 suPFLEMENT ARY NOTES g

,2 usTaACT,m -,

This report provides the status and result of the NRC Thermoluminescent Dosimeter (TLD:

Direct Radiation Monitoring Network. It pre "nts the radiation levels measured in the vicinity of NRC licensed facili'ty sits throughout the country for the first quarter of 1984.

/

7

./

ir

[ll t;

J 1

i. oOcuME T AN AL,,,. -.

E..o os oEsca,,Toas f

,. A,v,Ag,gT.

Thermoluminescent Dosimeter (;TLD) Direct Radiation Monitoring Network ambient radiation level';

Unlimited 14 SECumTY CLA$$1F. CATION

\\

(Th. pnpes

. iOENw,Easzo,EN ENoEo ""'

Unclassified o r.. -

'7 NuM8tR OF PAGES

\\

18 PRfCE

r -

~

[,

s L'

1

. UNITED STATES-couarw ctass uma I

..;MUCLEAR' REGULATORY COMMISSION

- e

"^j * '"* ""

. WASHINGTON, D.C. 20666 wasu. or -

Penwr me. e47

~ OFFICIAL BUSINESS /

- PENALTY FOR PRNATE USE, $300 -

,,S' M,.2, 120555078877 1 1ANING

'US NRC

'ADM-01V OF T10C

. POLICY E PUS MGT W-50t BR-PDR NUREG WASHINGTON DC 20555 6

k J

s L,:.

-1