]LLIN015 POWER COMPANY. ET AL, DOCKET N0 50-461 CLINTON POWER STATION, UNIT NO. 1 GMENDMENT TO FACILITY OPERATING LICENSC Amendment No. 64 License No. NPF-62 1.
The Nuclear Regulatory Commission (the Commission) has found that:
i A.
The application for amendment by Illinois Power Company * (IP), and Soyland Power Cooperative, Inc. (the licensees) dated December 17, 1990 and supplemented December 17, 1991, complies with the standards aad requirements of the Atomic Energy Act of 1954, as 4
amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; 8.
The f acility will cperate in cor.formity with the application, the provisions of the Act, and the reles and regulatiuns of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
Ti,e issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifi-cations as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-62 is hereby amended to recd as follows:
- llinois
..ser Company is authorized to act as agent for Soyland Power Cooperative, Inc. and has exclusive responsibility and control over the physical construction, operation and maintenance of the facility.
9208110299 920730 PDR ADOCK 05000461 p
W-.
(2)
Technical Soecifications and Environmental Protection Plan The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix 8, as revised through Amendment No. 64
, are hereby incorporated into this license.
Illinois Power Lompany shall operate the facility in accordance with the Technical Specifications ana the Envirci:mantal Protection Plan.
3.
This license amendment is effective as of its date of issuance.
FOR THE NUCLE REGULATORY COMMISSION h
Jo n N. Hannon, Director Project Directorate III-3 Division of Reactor Projects III/IV/V Office of Nuclear Reactor Reg _:ation
Attachment:
Changes to the Technical Specifications Date of issuance: July 30,1992
ATTACHMENT TO LICENSI AMENDMENT NO.64 FAClllTY OPERATING-LICENSE NO. NPF-62 DOCKET NO. 50-461 Replace the following pages of the Appendix "A" Technical Specifications with the attached pages.
The revised pages are identified-by amendment number and contain vertical lines indicating the area of change.
The corresponding overleaf pages are provided to maintain document completeness.
pemove Insert 3/4 3-48 3/4 3-48 3/4 3-49
.3/4 3-49 u
i 1
4
INSTRUMENTATION 3/4.3.4 RECIRCULATION PUMP TRIP, ACTUATION INSIRIJMENTAT10N ATWS RECIRCULATION PUMP TRIP SYSTEM INSTRUMENTATION LIMITING CONDIIJ0N FOR OPERATION 3.3.4.1 The anticipated transient without scram recirculation pump trip (ATWS-RPT) system instrumentation channels shown in Table 3.3.4.1-1 shall be OPERABLE with their trip setpoints set consistent with the values sSown in the Trip Setpoint column of Table 3.3.4.1-2.
APPLICABillTY: CPERATIONAL CONDITION 1.
ACTION:
With an ATWS-RPT system instrumentation channel trip setpoint less conserva-a.
4 tive than the value shown in the Allowable Value column of Table 3.3.4.1-2, declare the channel inoperable until the channel is restored to OPERABLE status with the cnannel trip setpoint adjusted consistent with the Trip Setpoint value, b.
With the number of OPERABLE channels less than required by the Minimum OPERABLE Channels per Trip System requirement for one trip system, place the inoperable channel (s) in the tripped condition within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least STARTUP within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
c.
With the number of OPERABLE channels one les: than required by the Minimum OPERABLE Channels per Trip System requiremer.t for both trip systems, place at least one inoperable channel in the tripped coadition within one hour, and place the second inoperable channel in the trlpped condition within 72 nours. Otherwise, be in a least STARTUP within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, d.
With both trip systems otherwise inoperable, restore a lor' on trip system to OPERABLE status within one hour or be in at least STARTUP within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
SURVEILLANCE REQUIREMENTS 4.3.4.1.1 Each ATWS-RPT system instrumentation channel shall be demonstrated OPERABLE by the performance of the CHANNEL CHECK, CHANNEL FUNCTIONAL TEST and CHANNEL CAllBRATION operations at the frequencies shown in Table 4.3.4.1-1, 4
4.3.4.1.2 LOGIC SYSTEM FUNCTIONAL TESTS cnd simulated automatic operation of all channels shall be performed at least once per 18 months.
CLINTON - UNIT 1 3/4 3-.48 Amend:aent No. 64 L
p TABLE _3.3.4.1-1 s
ATWS RECIRCULATION PUfiP TRIP SYSTEM INSTRUMENTATION O
i g;
MINIMiJJ OPERABLE CH{gyELS a
TRIP FUNCTION PER TRIP SYSTEM s
~
1.
Reactor Vessel ifater Level -
2 Low Low, Level 2 2.
Reactor Vessel Pressure - High 2
(a) One trip system may be placed in an inoperable status for up to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> for required surveillance provided the redundant trip system is UPERABLE.
u Y
S P
B a
n F.
.