_
METROPOLITAN EDIS0N COMPANY JERSEY CENTRAL POWER & LIGHT COMPANY AND PENNSYLVANIA ELECTRIC COMPANY THREE MILE ISLAND NUCLEAR STATION, UNIT 1 Operating License No. DPR-50 Docket No. 50-289 Technical Specification Change Request No. 38, Rev. 1 This Technical Specification Change Request is submitted in support of Licensee's request to change Appendix A to Operating License No. DPR-50 for Three Mile Island Nuclear Station, Unit 1.
As a part of this request, proposed replacement pages for Appendix A are also included.
GPU NUCLEAR CORPORATION BY 31 rector, TMI-1 Sworn and Subscribed to before me this 4L A day of %. 6)
, 1985.
y e-.y., s...g Notar'y Public va A n u er m o n.498,,,
R00l[10$N G0FO. DAufh N C00mit
- 7 CCMUl%iCN f!Nkis m%f 17,1%$
M:a F<r 1,
, e i a :, a' :m r.f % :tmes M 21888! 81888 6 P
5 UNITED STATES OF AMERICA l
l NUCLEAR REGULATORY COMMISSION i
IN THE MATTER OF DOCKET NO. 50-289 LICENSE N0. DPR-50 GPU NUCLEAR CORPORATION This is to certify that a copy of Technical Specification Change Request No. 38, Rev. I to Appendix A of the Operating License for Three Mile Island Nuclear Station Unit 1, has, on the date given below, been filed with executives of Londonderry Township, Dauphin County, Pennsylvania; Dauphin County, Pennsylvania; and the Pennsylvania Department of Environmental Resources, Bureau of Radiation Protection, by deposit in the United States mail, addressed as follows:
Mr. Jay H. Kopp, Chairman Mr. John E. Minnich, Chairman Board of Supervisors of Board of County Commissioners Londonderry Township of Dauphin County R. D. fl. Geyers Church Road Dauphin County Courthouse Middletown, PA 17057 Harrisburg, PA 17120 Mr. Thomas Gerusky, Director PA. Dept. of Environmental Resources Bureau of Radiation Protection P.O. Box 2063 Harrisburg, PA 17120 GPU NUCLEAR CORPORATION BY Director. TMI-1 DATE: thrch 5,1985
I.
TECHNICAL SPECIFICATION CHANGE REQUEST N0. 38, REV. 1 The Licensee requests that the attached revised pages replace the following pages of the existing Technical Specifications.
Replace page vii, 3-55, 3-56, 3-56a, 3-56b II.
REASON FOR CHANGE This change revises our previous submittal, Technical Specification Change Request No. 38, consistent with the guidelines of NUREG-0612 as outlined in "GPU Evaluation of Heavy Load Handling Operations at TMI-1" dated February 21, 1984.
This change is requested in order to define the lift conditions and allowable areas of travel when loads to be lifted and transported with the fuel handling building crane are in excess of 15 tons or between 1.5 tons and 15 tons or consist of irradiated fuel elements.
Additionally, the requested change revises restrictions on the movement of heavy loads, fuel shipping cask and fuel pool gates due to key operated travel interlocks and administrative controls which limit the travel area of the Fuel Handling Building Crane as described in the approved GPU Evaluation.
III.
SAFETY EVALUATION JUSTIFYING CHANGE Movement of heavy loads in the TMI-1 Fuel Handling Building shall be consistent with the guidelines of NUREG-0612 as outlined in "GPU Evaluation of Heavy Load Handling Operations at THI-1," approved in NRC Safety Evaluation Report dated January 11, 1985. The requested change to Technical Specification 3.11 specifies that administrative controls shall require the use of an approved procedure with an identified safe load path for loads in excess of 1.5 tons handled above the Spent Fuel Pool Operating Floor (348' elevation). A safe load path, as defined in the referenced GPU evaluation, shall minimize the potential for heavy loads, if dropped, to impact irradiated fuel in the spent fuel pool, or to impact redundant safe shutdown equipment.
IV.
N0 SIGNIFICANT HAZARDS CONSIDERATION The proposed changes provide enhanced measures to control the movement of heavy loads in the TMI-1 Fuel Handling Building and:
- 1) do not adversely affect plant design or operation since impact to irradiated fuel in the spent fuel pool and redundant safe shutdown equipment is mitigated and, therefore, would not involve a significant increase in the probability or consequences of an accident previously evaluated,
- 2) do not involve modifications to plant equipment which would create the possibility of a new or different kind of accident from any accident previously evaluated since the modified key operated travel interlocks preclude heavy load drops which would damage redundant safe shutdown equipment, and
- 3) do not involve changes which would adversely affect the safety analysis of the plant since the proposed changes would preclude the fuel handling accident analyzed in the FSAR, and, therefore, would not involve a significant reduction in a margin of safety, V.
IMPLEMENTATION It is requested that this amendment become effective November 1,1985.
VI.
AMENDMENT FEE (10 CFR 170.21)
Pursuant to the provisions of 10 CFR 170.21, a check for $150.00 will be sent under separate cover for this submittal.
i 0179A 1