ML20099A298

From kanterella
Jump to navigation Jump to search
Documents Discussion on 790116 Re 781023 Change to Tech Spec 4.5.5.b on ECCS Venting Periodicity.Three High Pressure Injection Lines Not Connected to Reactor Coolant Makeup Sys Were Vented on 790113;no Air or Gas Noted
ML20099A298
Person / Time
Site: Davis Besse 
Issue date: 01/26/1979
From: Roe L
TOLEDO EDISON CO.
To: Reid R
Office of Nuclear Reactor Regulation
References
482, NUDOCS 7902010103
Download: ML20099A298 (1)


Text

L ~-

N

(,)

av' g,

c.

TOLEDO i

EDISON Cocket No. 50-346 License No. NPF-3 LOWELL E. RCE Serial No'. 482 g',g'{L,,

14191 259-5261 A

January 26, 1979 Director of Nuclear Reactor Regulation Attention:

Mr. Robert W. Reid, Chief Operating Reactors Branch No. 4 Division of Operating Reactors U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. Reid:

This letter is to document the January 16, 1979 discussion between our Mr. F. R. Miller and Mr. Guy Vissing, NRC Licensing Project Manager, about the requested change to Davis-Besse Nuclear Power Station Unit 1 Technical Specification 4.5.2.b on ECCS venting periodicity submitted to you on October 23, 1978.

The three high pressure injection lines not connected to the reactor coolant makeup syttem were vented the weekend of January 13, 1979, after approxima.ely two years of operation. No air or gas was observed leaving the lines during the venting and r% lines were fo,und full of water.

In this two year period the high pressere injection system was not drained and was called on and activated twice.

Containment isolation valves that are required to be closed during I 3CA conditions are leak rete checked every 18 months.

Because these liaes in question are required to be operational for LOCA, the associated valves are to be open and are, therefore, not required to provide a containment isolation function or be leak rate checked.

If any additional information is required please contact us.

Yours very truly,

(

Tc d S.

M 1

LER/TJM 3h ri Wy DOCK o-1-<

i n

a ks c/28

$lQ g<

THE TCLEDO EDISON COMPANY EDISON PLAZA 300 MACISON AVENUE TCLEDO, OHfC 43652 790201Dlo3