POST TRIP REVIEW
Purpose:
The purpose of the post-trip review process is to determine the plant's readiness to return to power operation following an unscheduled reactor trip from other than shutdown or refueling modes of operation. Prior to returning tc cower operation, station personnel must reasonably determine the cause of the trip, verify the proper functioning of safety-related and other important equipment during the trip and ensure the trip did not have a detrimental effect on the plant. Also, the availability of Tech.
ec. and safety-related equipment is to be considered prior to startup.
Discussion:
The overall objective of the post-trip review i t
mining the acceptability of performing a reactor Any unscheduled reactor trip, except when t
fueling operations, will require a post-trip review pro; st tiated. The post-trip review shall be initiated af ter plant have stabilized and shall not distract the Shift Supervisor, ope personnel, or the Shift Engineer from their primary responsibility a nitoring plant parame-ters and maintaining the plant in a safe condition.
The duty Shift Supervisor has the overall responsibility for the safe
?
and reliable operation of the plant during his shift.
Therefore, he is responsible for the thoroughness and completeness of the post-trip review.
Sufficient data must be collected to perform a complete investigation.
The trip data should be collected as soon as feasible af ter the trip.
An important aspect of the data collection is the Operator observations during the trip. Personnel observing or participating in the trip can provide insights into the plant response not available frcm strip charts or computer printouts. Various methods are available to obtain the Operator input.
Written Operator statements, Operator interviews, or a meeting with all involved personnel are effective methods of obtaining Operator input.
Pertinent hard copy data is to be collected and attached to the post-trip report (strip charts and :omputer printouts.)
The basis for the review should be a ccmparisen with similar transients described in the FSAR or previous trip reports and the Technical Specifications to determine if the plant equipment functioned within design specifications. This documented review should help ensure events that may have had an impact on the cause of the trip and subsequent equipment response are identified and thoroughly understood.
The review results will permit a determination to be made as to the readiness of the plant to safely return to power operation.
The post-trip review will result in a recommen-dation for either a reactor restart or further investigation.
The trip event should be reconstructed, analyzed and evaluated to determine the most 8410090213 841002 PDR ADOCK 05000271 P
)a
,9
.,.s,
_2 A.P. 0154 Original
. probable cause of the trip, the proper functioning of safety-related and other equipment and any detrimental effects of the trip on the plant.
h The responsibility for the restart decision rests with the Plant Manager (or his designate). He will evaluate input from the individuals performing the trip review. The Plant Manager (or his designate) will j.
satisfy himself that the cause of the trip has been reasonably determined i
and actions have been taken to minimize the possibility of recurrence.
References l
A.
Tech. Specs.
1.
None
(
B.
Admin. Limits 1.
None C.
Other 1.
A.P. 0010, Occurrence Reports 2.
A.P. 0012, Notifications and Reports Due 3.
A.P. 0156, Significant Events Requiring Immediate Notification 4.
A.P. 3125, Emergency Plan Classification and Action Level Scheme 5.
A.P. 0834, Plant Record Retention l
6.
Generic Ltr 83-28, Salem ATWS Events Procedure:
A.
Post-Trip Investigation 1.
Data Collection a.
As soon as practical after plant conditions have stabilized, the Shift Engineer and any available Operators shall begin gathering event data. This will include, but not necessarily be limited to:
1)
Alarm / sequence of events typer output 2)
On-demand typer output 3) 80P typer output 4)
Core performance log typer output 5)
Useful recorded tracings of Control Room instruments 6)
Observations from plant personnel involved 2.
Event Reconstruction a.
The Shift Supervisor (or SR0 designate) and the Shift Engineer will reconstruct the transient using the collected data. A chronological description of the event will be deve-loped using available data.
n',
\\
_3
.I A.P. 0154 Original 3.
Analysis and Evaluation a.
The Shift Supervisor (or SRO designate) and the Shift Engineer shall analyze and evaluate the event reconstruction, using VYAPF 0154.01, to detennine the cause of the trip and the following:
1)
If all major safety-related and other important equip-ment involved in the trip operated as anticipated or expected.
2)
If the trip / transient caused any detrimental effects on plant equipment.
3)
If it is acceptable to restart the reactor.
b.
The review shall look beyond the obvious indications to diagnose the cause of the trip and evaluate the plant response. Review the available indications thoroughly, looking for 1) abnormal indications or degraded trends in equipment performance, 2) events occurring out of the normal or anticipated sequence, 3) failed or degraded response of equipment to control signals, 4) unusual chemistry results or radiation readings, and 5) unanticipated alarms.
c.
It is important to understand the cause of an unscheduled trip so that a recurrence can be avoided after restart.
It is not realistic however, to ignore the possibility for spurious trips whose cause cannot be identified.
In the event that the cause of the trip cannot be determined, and the safety systems have indicated a proper response, a restart can be recommended based on the following conditions:
1)
Any further reasonable actions to determir.e cause are considered.
2)
No physical damage was done by the event and a deter-mination was made that the plant had not operated beyond the boundaries established by approved plant safety and transient analysis.
3)
Any reasonable action to gain additional information has been considered.
4)
Satisfied of a reasonably low potential for recurrence.
O l
l L
i,,
_g_
A.P. 0154 Original NOTE:
If the duty Shift Supervisor did not actually perform.the trip investigation, he shall review and approve the post-trip
. report.
14.
Review The completed " Post-Trip Report" should be forwarded to the a.
Operations Supervisor for review.
B.
-Investigation Review 1.
Higher plant management shall be notified of the results of this l
investigation to assist in.the restart decision. The following criteria shall be used for the restart decision:
a.
The cause of the trip has been determined and corrected.
b.
Major safety-related and other important equipment functioned properly or corrective maintenance and satisfactory testing have been performed on such.
c.
The plant responded as anticipated or abnormalities are understood and corrected as per the Techqical Specifications.
NOTE:
Higher management notification and restart decision may be verDal
_l over the telephone.
2.
If the criteria of 8.1 above are not met, then further review shall be conducted by a " Post _ Trip Committee" consisting of the Operations Superintendent and the Operations Supervisor (or their designates as a minimum). The Operations Superintendent will solicit other department and~ individual participation in the Committee as needed. This Committee should analyze the event reconstruction, emphasizing the determination of the cause of the trip and resolution of abnormal or degraded conditions. The Committee should consider (but not be limited to) the following:
a.
The actual or most probable cause of the trip.
3 b.
The maintenance and testing necessary before reactor restart, including additional. measures to verify the most probable Cause.
c.
Additional monitoring or trending required during and/or after reactor restart.
9 M
e
- e., ;
5 A.P. 0154' Original d.
Necessary briefings to Operations and station personnel con-cerning specific equipment indications or possible malfunctions.
e.
The conditions necessary for a reactor restart.
3.
The end result'of either review process outlined above should be a recommendation to the Plant Manager to assist in his decision to restart the reactor.
4.
The Plant Operations Review Committee (PORC) should review all post-trip reports at their next scheduled meeting.
S e
-g>-r---~
-.7--,---c_-,,,__
~ ' ' ' " ' '
~
4
POST-TRIP REPORT -
-Dates-Time:
Report No.:
PERSONNEL Duty Shift Supervisor Duty SCRO:
Duty CRO:
Duty ACRO:
Outy Shift Engineer:
Others Involved:
INITIAL CONDITIONS:
Reactor Power (MWt)
Rx Vessel Press (psig)
~
Vessel Level (in)
Status of Control Stations: Recirc Pump Control:
Vessel Level Control:
Turbine Control:
Off-normal-status of any portions of safety systems prior to trip:
Testing / Surveillance in Progress:
i Other significant initial conditions:
VYAPF 0154.01 Original Page 1 of 7
__-_.-_-___--_.____.---_______-..-_.----_-_-_,_.--a
POST-TR1P REPORT 4 #.
SEQLENCE OF EVENTS Plant Evolutions Preceeding Scram:
Cause(s) of Scram:-
t t
4 1
Event Reconstruction:
- Time Event
Description:
I' 4
S
- WAPF 0154.01
. Original Page 2 of 7 Wr n
.---e u-+-.
..-.4-.-n.me-
,,y,,
_,s-,
.w-,.e,-m--..
,,_,-._,w_g.w 4-wm,,,-ym,y,,,,-,w.m,,,
m,-m.nw._wp.
,y p. m
FCST-TR1P REPORT
~-
Event Reconstruction (Cont.)'
[
I Time Event
Description:
r i
4 4
i s
d i
I (Attach Additional Sheets as Required)
LWAPF 0154.01-Original Page 3 of 7
. J.
, o r,' : [ ["
POST-TRlP REPORT PLANT RESPONSE
- -Evaluate if useful information is contained on any strip recorders and retain as necessary (attach to report).
-Computer edits are to be' retained (attach to report).
System Responses:
4 1.
Emergency Diesel Ger.arators-
-2.
Turbine and Auxiliaries 4
3.
CRD System (include monitored scram times)-
.i i
4.
4 1
.VYAPF 0154.01
- Original _
Page 4 of 7
~$1--
POST-TRIP REPORI
. :
- 3,,
e;,
3
+
5.
ECCS Systems (HPCI, CS,- LPCI, AOS, RCIC) f e
1 2
- 6.-
Safety Valves and/or Relief Valves i
-7.
'PCIS s
[
h VYAFT 0154.01-~
Page 5 of 7
- Original g
T p
-g-gg.
v
,,vev-y--vy
,p w-$m
,-r,ve*,-y
- v y w
-v, w - ww w y w, + v v
-r yy*.
r-vv v-wwwr-wwwcwh--w-e y-
-r-v w --u v-e-*s-+ew---
-+-w-r~W6
++*-P+-M+nw-v--'37+
I'.'
,.l POST-TRIP REPORT
. :s.
- 8.-
- Radiological Response 4.
9.-
' Chemistry Response 9
1
~10.
Other Systems / Components 4
l ^
t r
4 e
(
VYtPF 0154.01 Original-Page 6 of 7 yw +--
+y-7__ay=-.yy.-9...
-,,m.rr
--<&m-e-
+=-r'e
+,+-w+-W~*
w'evvarwmebw w ev-
-=-h-miw w -+ i c w - in-w r
ve+ w er- ~ ~ r m +
+w+d-.-w*e-w-n+s&-et w m-wi-y
. d.1,,1
..i FOST-TRIP REPORT
~
' Summary:
Systems / components with inadequate pertormance:
System / component Description of problem Comments:
Signature indicates agreement with report contents:
Reviewed by:
Shift Supervisor Date Time Reviewed by:
Shift Engineer Date Time z
Reviewed by:
OPS Supervisor Date Reviewed by:
PORC Secretary Date Any subsequent findings or additional information, including Review Committee recommen-
. dations or PORC Review Minutes, should be attached to report for future reference.
' WAFF 0154.01 Original.-
Page 7 of 7
-