Forwards Corrections/Clarifications to ERDS Survey & Data Point Library Ref Files,Originally Submitted Via
ML20098D270
Person / Time
Site: Peach Bottom, Limerick  
Issue date: 05/21/1992
From: Beck G
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9205280160
Download: ML20098D270 (30)


Text

m PIIILADELPillA ELECTRIC COMPANY NUCLEAR GROUP llEADQUARTERS 955-65 CilESTERilROOK BLVD, WAYNE. PA 19087 5691 (215) 640 6000 May 21, 1992 NUCLEAR LNGINEERING & $0RVICf3 DffARTMr.NT Docket Nos. 50-277 50-278 50-352 50-353 License Nos. DPR-44 DPR-56 NPF-39 NPF-85 U.S.

Nu ' ear Regulatory Commission Attn bucument Control Desk Washington, DC 20555

SUBJECT:

Peach Bottom Atomic Power Station, Units 2 and 3 Limerick Generating Station, Units 1 and 2 Completion of Emergency Response Data System Survey and Data Point Library Reference Files

REFERENCE:

')

Letter from G.

J. Beck (PECo) to USNRC, dated February 19, 1992 Dear Sir In the Refercnce 1 letter, Philadelphia Electric Company (PEco) provided a copy of a completed Emergency Response Data System (ERDS) survey and data point library reference files for Peach Bottom Atomic Station (PBAPS), Units 2 and 3, and Limerick Generating Station (LGS),

Units 1 and 2.

In subsequent telephone calls (Westesday, March 18, 1992, Thursday, March 19, 1992 and Wednesday, May 5, 1992) between M.

Olivera (PECo) and J. Jolicoeur (USNRC), several corrections and clarifications to the Reference 1 information were identified.

As a result, Attachment A and Attachment B contain revised data point library reference files and revised survey information for LGS and PBAPS respectively.

If you have any questions, please contact us.

Very truly yours,

/s G.

J.

Beck, Manager

. v o u., 3 Licensing Section

,ppn4 Attachmonts

'7/'fj cc T.

T Martin, Administrator, Region I, USNRC

/)

J.

J.

Lyash, USNRC Senior Resident Inspector, PBAPS T.

J.

Kenny, USNRC Senior Resident Inspector, LGS

(\\

9205280160 920521 PDR ADOCK 05000277 I

.. _. _, F_

_, P D R_ _._ _ _ __

Attachment A F..

--m_-_

___.__m

._m..

. -.m._-.__.__._._____._._.___.___.__._._._...._.._.____.__..__._._

i l

3.

Data Communication Details Can this data feeder provide asynchronous serial data communication (RS-232.C) a.

with full-modem control?

YES b.

Will this feeder transmit in ASCII or EBCDIC?

ASCII Can this feeder transmit at a serialbaud rate of 2400 bps? If not, at what baud rate can c.

it transmit?

YES d.

Does the operating system support XON'XOFF flaw control?

YES, however PECo's application uses Sucpend/Resune protocol.

1.

A.re any problems foreseen with the NRC using XON/XOFF to control the trans-mission of data?

YES e.

If it is not feasible to reconGgure a serial pcrt for the ERDS linkup (i.e., change the baud rate, parity, etc.), please explain why.

N/A f.

Can the serial port dedicated to the ERDS be conGgured so that the NRC need not emulate a specific brand of terminal (i.e., can it be configured to be a " vanilla" l

terminal)?

i-YES-B-9 1

d i

NRC DATA POINT LIBRARY REFERENCE FILE

]

Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LM1 11 N/A Data Feeder:

NRC ERDS Parameter (12 char):

NI SOURC RNG Point ID (12 char):

E1114 i

Plant Syce Point Dese(40 char):

A SRM POSm0N GeneHe/Cond Dese(32 char):

NUCLEAR INSTRUMENTS SOURCE RANGE onalog/ Digital:

D Engr Units / Dig States (12 char):

IN/NOTIN i

Engr Units Conversion (40 char):

0= FULL IN /1 = NOT IN Minimum Instr Range (10 char):

N/A Maximum Instr Range (10 char):

N/A

~

Zero Point Reference (0 char):

N/A Reference Point Notes (40 char):

N/A EROC or SENS:

S Number of Sencors(3 char):

1 Ilow Processed (40 char):

N/A Sensor Locations (40 char):

SIIUTTLE TUBE Ahtrm/, Trip Set Points (40 char):

N/A NI Detector Power Supply Cut.off N/A Power Level (15 char):

NI Detector Power Supply Turn on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provido correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

NI SOURCE RANGE MONITOR POSITION IS VARIABLE l

BETWEEN 30" DELOW BOTTOM OF ACTIVE FUEL TO 18" ABOVE MIDPLANE (FULLINK l

l L

DPL 11 OF 65

.~

NRC DATA POINT LIBRARY REFERENCE FILE

^

Date:

12 / la / 91

~

IEcactor Unit (Lhil or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameier (12 char):

NI SOURC RNG Point ID (12 char):

E1133 Plant Spec Poun. Dese(40 Aar):

B SRM POSITION Generic /Cond Desc(32 char):

NUCUW1 INSTRUMENTS SOURCE RANGE Analog /lligitah D

Engr Units / Dig States (12 char):

IN/NOT IN Engr Units Conversion (40 char):

0-FULL IN /1 = NOT IN Minimum Instr Range (10 char):

N/A

~

Maximum Instr Range (10 char):

N/A Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A l

EROC or SENS:

S i

Number of Gensors(3 char):

1 llow Processed (40 char):

N/A Sensor Locations (40 char):

SIlUTTLE TUDE Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut-cir -

N/A Power Level (15 char):

NI Detector Power Supply Turn-on

?.A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A 9

Temperature Compensation for DP N/A Transmitters (Y or N,if No provide correction cun'e)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

NI SOURCD RANGE MONITOR POSITION IS VARIABLE BETWEEN 30' BELOW BOTTOM OF ACTIVE FUEL TO IS* ABOVE MIDPLANE (Full 1N).

DPL 12 OF 65

NRC DATA POINT LIBRARY REFERENCE FILE 12/18/91 Date:

~

IAll lleactor Unit (I.M1 or LM2):

Data Feeder:

N/A NI SOURC RNG NRC EItDS Partune, (12 char):

~

Point ID (12 char):

E111r, C SRM POSITION Plant Spec Point Desc(40 char):

EUCLEARINSTRUMENTS SOURCE RANGE Generic /Cond Dest (32 char): _

D Analog /. Digital:

IN/NOT IN Engr Units / Dig States (12 char);

Engr Units Conversion (40 char):

0 = FULL IN /1 = NOT !Il Minimum Instr Itzinge(10 char):

N/A Maxiinum Instr 1(unge(10 char):

N/A Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS' S

Number of Sens rs(3 char):

1 Ilow Processed (40 cl.nr);

N/A Sensor Locations (40 char)y SIIUTTLE TUBE N/A Alarm / Trip Set Pointsf40 char): _

N/A NI Detector Power Supply Cut-off Power Level (15 char):

N1 Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N,if No provide correction curve)):

N/A Igvel Reference Leg (WET or DRY):

_ NI SOURCE RANGE MONITOR POSITION IS VARIABLE Unique System Desc.(600 char):

BETWEEN 30" BELOW BOTTOM OF ACTIVE FUEL TO IS" ADOVE MIDPLANE (FULLIN).

4 NRC DATA POINT LIBRARY REFERENCE FILE Date:

l / IS / 91 Reactor Unit (12.11 or LM2):

12 11 Data Feeder:

N/A NRC EltDS Parameter (12 char):

N1 SO RC RNG Point ID (12 char):

E1139 Plant Spec Point Dese(40 char):

D SRM P051T10N Gencric/Cond Dese(32 char):

NUCEAiUNSTRUMENTS SOURCE RANGE Analo;t/ Digital:

D Engr Units / Dig States (12 char):

IN/NOT IN Engr Units Conversion (40 char):

0 = FULL IN / I n NOT IN Minimum Instr Range (10 char):

N/A Maximum Instr Range (10 char):

N/A Zero Point Reference (G char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 llow Processed (40 char):

N/A Sensor Locations (40 char):

SHUT'ILE TUBE Ahtrm/ Trip Set Points (40 char):

l'/A

(

NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N,if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A 5

Unique System Desc.(600 char):

NI SOURCE RANGE MONITOR POSIT 16N IS VARIABLE BE'lWEEN 30' DELOW EOTTOM OF ACTM' FUEL TO IS' ABOVE MIDPIANE (FULLIN).

DPL 14 OP 65

NRC DATA POINT l.lBRARY REFERENCE Fil.E Date:

12 / 18 / 01 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

RCS PRESSUlG Point ID (12 cl ar):

E1430 Plant Spec Point Dese(40 char):

UPSET RANGE REACTOR PIGSSURE B Generic /Cond Dese(32 char):

RX COOLANT SYSTEM PRESSURE' Analog / Digital:

A Engr Units / Dig States (12 char):

PSIG Engr Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

1500 Zero Point Reference (0 char):

N/A Reference Point Notes (40 char):

N/A EROC or SENS:

S Number of Sensors (3 char):

1 llow Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

HIGH @ 1020, SCRAM HI @l037, SCRAM LOW @756 NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N,if No provide correction curve)):

Level Re~ference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

REACTOR VESSEL PRESSURE IS SENSED IN STEAM DOME AREA.

DPL 27 OF 65

~.

l NRC DATA POINT LIBRARY REFERENCE Fil.E Date:

12 /18 / D1 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC EllDS Parameter (12 char):

EFF GAS RAD Point ID (12 char):

4TE070 Plant Spec Point Dese(40 char):

N STACK TOTAL EFFLUENT Generic /Cond Dese(32 char):

RADIOACTIVITY OF RELEASED G ASSES Analog / Digital:

A.

Engr Units / Dig States (12 char):

Mcl/s Engr Units Conversion (40 char):

Minimum Instr Ibmge(10 char):

Maximum Instr Range (10 char):

Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A

~P. ROC or SENS:

P Number of Sensors (3 char):

N/A Ilow Processed (40 char):

N/A Sensor Locations (40 char):

NORTH STACK SAMPLE GRID Alarm / Trip Set Points (40 char):

ALERT @ LO3E4 mci /S,IIIGli @l.03E5 MCI /S NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A e

Transmit ters(Y or N,if No provide i

correction curve)):

Level Reference Leg (WET or DitY):

N/A

! Unique System Desc.(600 char):

l l

l DPL 37 OF 65

i NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC EltDS Parameter (12 char):

RCS PRESSURE Point ID (12 char):

E1353 Plant Spec Point Desc(40 char):

UPSET RANGE REACTOR PRESSURE A Generic /Cond Desc(32 char):

RX COCLANT SYSTEM PRESSURE i

Analog /Digitah A

Engr Units / Dig States (12 char):

PSIG En'gr Units Conversion (40 char):

LINEAR Minimum Instr ihmge(10 char):

0 Maximum Instr Ihmge(10 char):

1500 Zero Point Reference (6 char):

N/A Referenco Point Notes (40 char):

N/A EROC or SENS:

S Number of Sensors (3 char):

1 IIow Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

1HGli @ 1020, SCRAM IU @l037, SCRAM LOW @756 NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

o Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N,if No provido correction curve)):

Level Reference Leg (WET cr DRY):

N/A Unique System Desc.(600 char):

REACTOR VESSEL PRESSURE IS SENSED IN STEAM DOME AREA.

l DPL 28 OF 65

NRC DATA POINT 1.lBRARY REFERENCE FILE

^ -~ 1 Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

Dil Data Feeder:

N/A

~~l NRC ERDS Parameter (12 char):

MND DIR Point ID (12 char):

T1.DR.I l

Plant Spec Point Dese(40 char):

TOWER 1 DIRECTION Generic /Cond Desc(32 char):

WIND DIR AT RFACTOR SITE Analog / Digital:

A Engr Units / Dig States (12 char):

DEGREES Engr Units Conversion (40 char):

IJNEAR Minimum Instr Range (10 char):

0 l

Maximum Instr Range (10 char):

540 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A EROC or SENS:

s Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut-oft N/A Power Level (15 char):

NI Detector Power Supply Turn on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve))-

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

TOWER 1 IS A 280' TOWER SITUATED APPROX 3000' 5U/ l OF TIIE LGS STRUCTURE VENTS. GRADE ELEVATION i IS 250' MSL. USED AS PIUMARY INDICATION OF WD :

DIRECTION. Wind direction is measured from directier wind.

DPL 60 OF 65 1

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 01 I{eactor Unit (LM1 or LM2):

LM2 Data Feeder:

N/A J

NilC EiiDS Parameter (12 char):

NI SOUllC 10,0 Point ID (12 char):

E2114 Plant Spec Point Desc(40 char):

A SRM POSITION Generic /Cond Desc(32 char):

NUCLEAR INSTRUMENTS SOURCE RANGE D

Analog /))igital:

Engr Units / Dig States (12 char):

IN/NOTIN Engr Units Conversion (40 char):

0=FULLIN /1-NOT IN Minimum Instr llange(10 char):

N/A Maximum Instr Itange(10 char):

N/A

~

~

Zero Point 1(oference(6 char):

N/A

~

lieference Point Notes (40 char):

N/A YROC or SENS:

s

~

Number of Sensors (3 char):

1 Ilow Processed (40 char):

N/A Sensor Locations (40 char):

SliUTTLE TUHE Alarm / Trip Set Points (40 char):

N/A N1 Detector Power Supply Cut off N/A Power Levol(15 char):

NI Detector Power Supply Turn on N/A Power Level (15 char):

~

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitterc(Y or N, if No provide i-correction curve)):

Lovel Reference Leg (WET or DRY):

N/A Unique System Dese.(000 char):

NI SOURCE RANGE MONITOR POSITION IS VARIABLE DETWEEN 30' BELOW BOTTOM OF ACTIVE FUEL TO IS' ABOVE MIDPLANE (FULI,IN).

I h

DPL 11 OP 65

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 j

Reactor Unit (LM1 or LM2):

LM2 Data Feeder:

N/A 4

'NRC ERDS Parameter (12 /

w NI SOURC RNO Point ID (12 char):

E2133 Plant Spec Point Desc(40 char):

B SRM POSITION Generic /Cond Desc(32 cbar):

NUCI EAR INSTRUMENTS SOURCE RANGE bnalog/ Digital:

D Engr Units / Dig States (12 char):

IN/NOT IN Engr Units Conversion (40 char):

0-FULL IN /1-NOT IN Minimum Instr Range (10 char):

N/A Maximum Instr Range (10 char):

N/A Zero Point Reference (G char):

N/A Reference Point Notes (40 char):

N/A EROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

SIfUTTLE TUBE Alarm / Trip Set Points (40 char):

N/A l

NI Detector Power Supply Cut off N/A Power Level (15 char):

N1 Detector Power Supply Turn on N/A Power Level (15 char):

Instrument Failure Modc(30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N,if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

NI SOURCE RANGE MONITOR POSITION IS VARIABLE BETWEEN 30' BELOW BOTTOM OF ACTIVE FUEL TO 18' ABOVE MIDPLANE (FULLIN).

&&S ee e O 6e *

  • S * * * ***** e 4* e4 e eee e.+e DPL 12 0F 65

-._..._-_.._..2,__

_.c-,._,

1 NRC DATA POINT LIBRARY REFERENCE 1:ll.E Date:

12 / 18 / 91 Iteactor Unit (LM1 or LM2):

' ML Data Feeder:

N/A NitC ERDS Parmneter (12 char):

NI 50URC RNO Point ID (12 char):

E2115 c S10.1 P051T'ON Plant Spec Point Dere(40 char):

NUCLEAR INSTRUm:NT5 SOURCE PANGE Generic /Cond Dese(32 char):

1)

Analog /D_igitpi:

IN/NOT IN Engr Units /Di;; States (12 char):

Engr Units Conversion (40 char):

f FULLIN /1= NOT IN Minimum Instr Itange(10 char):

N/A Maximum Instr llange(10 char):

N/A Zero Point lleference(G char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (fchar):

N/A 1

Ilow Processed (40 char):

slIUTTLE TUBE Sensor Locations (40 char):

_N/A Alarm / Trip Set Points (40 char):

NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

N1 SOURCE RANGE MONITOR POSITION IS VARIABLE BETWEEN 30" DELOW BOTTOM OF ACTIVE FUEL TO IS' ABOVE MIDPLANE (FULL IN).

DPL 13 OF 05

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12/IS/01 Reactor Unit (LM1 or LM2):

LM2 Data Feeder:

N/A NRC EllDS Parameter (12 char):

N1 SOURC RNG Point ID (12 char):

E2139 Plant Spec Point Dese(40 char):

D SRM POSITION Generic /Cond Dese(32 char):

NUCLEARINSTRUMENTS SOURCE RANGE hnalog/Dhntah p

Engr Units / Dig States (12 char):

IN /NOTIN Engr Units Conversion (40 char):

0 = FULLIN /1=NOT IN Minimum Instr Ihmge(10 char):

N/A Maximum Instr Range (10 char):

N/A Zero Point Reference (6 char):

N/A l

Reference Point Notes (40 char):

N/A EROC or SENS:

s Number of Sensors (3 char):

1 Ilow Processed (40 char):

N/A Sensor Locations (40 char):

SIIUTTLE TUBE Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A l

Transmitters (Y or N,if No prwide correction etuve)):

Level Reference Leg (WET or DRY):

N/A Unique System Dese.(600 char):

NI SOURCE RANOE MONITOR POSITION IS VARIABLE l

BETWEEN 30' BELOW BOTTOM OF ACTIVE FUEL TO h-18* ABOVE MIDPLANE (FULLIN).

L l:

I DPL 14 OF 65 i

l

_ a.,...

-,.-..:_u..,_.,_____--_._._,._,_._

NRC DATA POINT LIBRARY REFERENCE FILE i

Date:

12 / 18 / 91 Itcactor Unit (LM1 or LM2):

LM2 Data Feeder:

N/A NRC EllDS Parameter (12 char):

RCS PRESSURE Point ID (12 char):

E2234 Plant Spec Point Dese(40 char):

NARROW RANGE REACTOR PRESS Generic /Cond Dese(32 char):

RX COOLANT SYSTEM PRESSURE Analog /lligital:

A Engr Units / Dig States (12 char):

PSIG Engr Units Conversion (40 char):

LINMAR Minimum Instr Range (10 char):

550 Maximum Instr Range (10 char):

1050 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A EHOC or SENS:

S Nurnber of Sensors (3 char):

1 llo7 Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

HIGH @ 1020,SCRAF IU @ 1037, SCRAM LOW @756 N1 Detector Power Supply Cut off N/A Power Level (15 char):

NI Detector Power Supply Turn on N/A l

Power Level (15 char):

Inrtrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N,if No provide correction curve))-

~ Level Reference Leg (WET or DRY)':

N/A Unique System Dese (600 char):

REACTOR VESSEL PRESSURE IS SENSED IN STEAM DOME AREA.

DPL 26 0F 65 w.

...._..a-_,-.-.._._...-_,,,,-,.._,-

NRC DATA POINT UBRARY REFERENCE Fil.E

~~~

~

12 / 18 / 91 Date:

~

1312 Ileactor Unit (LM1 or IJ12):

Data Feeder:

N/A NitC EltDS Parameter (12 clia~r):

RCS PRESSURE Point ID (12 char):

E2430 Plant Spec Point Dese(40 char):

UPSET RANGE REACTOR PRESSURE B Generic /Cond Desc(h2 char):

RX COOLANT SYSTEM PRESSURE Analeg/Higital:

A Engr Units / Dig States (15 charg PSto "pgr Units Conversion (40 char):

LINEAR iinimum Instr lhmge(10 char):

0 Maximtun Instr Itange(10 char):

1500 Zero Point Reference (G cher):

N/A lleference Point Notes (40 char):

ii/A PitOC or SENS:

S Number of Sensors (3 char):

1 IIrw Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

Il1GH @ 1020, SCRAM In @ 1037, SCRAM LOW @756 NI Detector Power Supply Cut-off N/A Power Level (15 char):

N1 Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Modet30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correctior. curve)):

N/A Leveliteference Leg (WET or DRY): ~ RlWTOR VESSEL PRESSURE IS SENSED IN STEAM Unique System Dese.(600 char):

DOME AREA.

l DPL 27 OF 65

9 NRC DATA POINT LIBRAF / REFERENCE FILE Date:

12/lb/01 Reactor Unit (LM1 or LM2):

LM2

~

Data Fceder:

N/A NRC ERDS Parameter (12 char):

RCS PRESSURE

~

Point ID (12 char):

E2353 Plant Spec Point Dese(40 char):

UPSET RANGE RRACUJR PRESSURE A Generic /Cond Desc(32 char):

RX COOLANT SYSTEM PRESSURE Analog / Digital:

A Engr Units / Dig States (12 char):

PstG Engr Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0

~-

Maximum Instr Range (10 char):

1500 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A

~

PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char);

N/A Alarm / Trip Set Points (40 char):

EGH @ 1020, SCRAM HI @ 1037, SCRAM LOW @756 NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrtunent Failure Mode (30 char):

N/A Temperature Compensation for l,P N/A Transmitters (Y or N,if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A~

Unique System Dese.(600 char):

REACTOR VMSEL PRESSURE IS SENSED IN STEAM DOME ARPA P"L 28 OF 65

i i

L NRC DATA POINT UBRARY REFERENCE fil.E j

~

I p,.cI 13 / 18 / 91 l

~

Reactor Unit (LM1 or LM2):

LM2

~

Data Feeder:

N/A NRC ERDS Parameter (12 char):

EFF GAS PAD Point ID (12 char):

4TE076 1

Plant Spec Point Desc(40 char):

N STACK TOTAL EFFLUENT H

Generic /Cond Dese(32 char):

RADIOACTIVRT OF RELEASED GASSES

-Analog /I]igital:

A Engr Units / Dig States (12 char):

Mcl/s

]

Ergr Units Couursion(40 char)i Minimum Instr Range (10 char):

Maximum Instr Range (10 char):

~S ^

' ~

Zero Point ILference(6 char):

/^

Reference Point Notes (40 char):

N/A P

l EROC or SENS:

Number of Sensors (5 char):

' N/A IIow i)rocessed(40 char):

N/A

~ Sensor Locations (40 char):

NORTH STACK SAMPLE GRID Alarm / Trip Set Points (40 char):

ALERT @ LUSE4 MC1 G,HICH @l.0SE5 MCI /S NI Detector Power Supply Cut-off N/A Power Level (15 char):

~

~~

~NI Detector Power Supply Turn-on _

. N/A Power Level (15 char):

i Instrument Failure Mode (30 char):

N/A Temperature Ccemensation for DP.

N/A Transmitters (Y or N,if No provide correction curve)):

Level Reference LegGVET.or DRY):

N/A-Unique System Dese.(600 char):

i ii.

'x 4

4 DPL 37 OF 65 gA

_y j

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / IS / 91

]

Reactor Unit (LM1 or LM2):

LM2 Data Feeder:

N/A NRC ERDS Parameter (12 char):

WIND DIR Point ID (12 char):

TLDRI Plant Spec Point Desc(40 char):

TOWER 1 DIRECTION Generic /Cond Dese(32 char):

WIND din AT REACTOR SITE Analog / Digital:

)A Engr Units / Dig States (12 char):

DEGREES IJNEAR Engr Units Conversion (40 char):

Minimum Instr Range (10 char):

0 Marimum Instr Range (10 char):

540 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

.S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

N/A NI Deteuor Power Supply Cut-otT N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N,if No provide correction curve)):

Level Reference Leg (WET or DRY);

N/A l

Unique System Desc.(600 char):

' TOWER 1 IS A 250' TOWER SITUATED APPROX 3000' NW OF THE LGS STRUCTURE VENTS. GRADE ELEVATION l

IS 250' MSL. USFS AS PRIMARY INDICATION OF %TND DIRECTION. Wimd direction is measured from direction of wind.

l DPL 60 OF 65

NRC DATA PONT LIBRARY REFERENCE FILE

~

Date:

12 /18 / J1 Reac: - Unit (LM1 or LM2):

LM2

' Data Feeder:

.N/A NRC ERDS Paratnoter (12 char):

WIND DIR Point ID (12 char):

T2.DRU Plant Sgec Point Desc(40 char):

TOWER 2 DIRECTION Generic /Cond Dese(32 char):

WIND DIR AT REACTOR SITE Analog / Digital:

A Engr Units / Dig States (12 char):

DEGREES rh.gr Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximtun Instr Range (10 char):

540 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 chur):

N/A Alarm / Trip Set Points (40 char):

LINEAR NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Levein5 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference LegGVET or DRY):

_N/A Unique System Desc.(600 char):

TOWER 2 IS A 310' TOWER SITUATED APPROX 2100' WEST OF THE LGS STRUCTURE VENTS. GRADE '

ELEVATION IS 121' MSL. USED AS SECONDARY INDICATION OF WIND DIRECTION. Wind direction is measured from riirection of wind.

DPL 61 OF 65

s Attachment B O

I. Contacts Note: Please provide name, title, mailing address, and phone number.

A. Survey Coordinator (i.e., contact for later clarification of questionnaire answers):

Michael C. Desesa

Title:

Computer Engineer Phile.delphia Electric Company Phone:

(717) h56-701h Ext. 3273 Peach Bottom Atccie Power Station RD #1, M.C. - Ah-)4N Delta, PA 1731h B.

Computer Hardware Specialist (s):

892 C. Systems Software Specialist (s):

SAME D.

Application-level Soft,vare Specialist (s):

ses W

E.

Tm. : phone Systems Specialist (s):

SAE B-2 s

4 3.

Data Communication Details Can this data feeder provide asynchronous serial data communication (RS-232-C) a.

with full-modem control?

YES b.

Will this feeder transmit in ASCII or EBCDlC?

ASCII c.

Can this feeder transmit at a serial baud rate of 2400 bps? If not, at what baud rate can it transmit?

.u YE3 d.

Does the operating system support XON/XOFF flow control?

YES, however, PECo's application usec Suspend / Resume protocol.

1.

Are any problems foreseen with the NRC using XON/XOFF to control the trans-mission of data?

YFS If it is not feasible to reconfigure a serial port for the ERDS linkup (i.e., change the e.

baud rate, parity, etc.), please explain why.

N/A f.

Can the serial port dedicated to the ERDS be configured so that the NRC need not emulate a specific brand of terminal (i.e., can it be configured to be a " vanilla" terminal)?

YES B -9 l

O

_ _ _ _ - _ _ _. _ _ - __~ --

m DATA POINT LIBRARY REFERENCE FILE Date:

1/15/92 Reactor-Unit:

PE2 Data Feeder:

N/A HRC ERDS Parameter:

EFF GAS RAD

?

Point ID:

SPDS1288 Plant-Spec Point Desc:

/ VG VENT ST.*.CK RAD - NR or WR Generic /Cond-Dese.:

RADIOACTIVITY OF RELEASED GASSES 1

1

-Analog / Digital:

A Engr Unite / Dig States:

CPM 1

Engr. Units Conversion:

Minimum Instr Range:

10 14 Maximum Innt.r Range 1 x 10 Zaro Point

Reference:

Reference Point Fotes:

PROC or SENS:

E Number of Sensors:

3 How Processed:

RAMGE SELECTED AVERAGE Sensor Locations:

NFAR TOP OF VENT STACK Alarm / Trip Set Points:

HIHI=100,000 CPM NI Detector Power Supply Cut-off-Power Level:

MI Detector Power Supply Turn-on Power Level:

-Instrument' Failure Mode:

-LOW I

Temperature Compensation

For DP Transmitters

Level Reference Leg:

s i.

Unique System Desc.-

AVERAGE ROOF VENT STACK NR OR WR.

THIS RANGE SELECTED AVERAGE NORMALLY DISPLAYS THE AVERgGE OF TWO LOW RANGE (10 CPM - 10 CPM)

RADIATION MONITORS.

IF BOTH LOW i:

w 7

y St

-v y-

,iti'r r------

,+mm,wP pn

RANGE MONITORS FAIL OR IF GENT STACK RAD LEVEL EXCEEDS 10

CPM, THEN THE DISPLtjYED VALUE }S FROM A y

HIGH RANGE (10 CPM - 10 CPM)

RADIATION MONITOR.

A SAMPLE OF VENT STACK DISCHARGE IS DRAWN FROM ISOKINETIC N0ZZLES LOCATED NEAR THE TOP OF THE VENT STACK.

M 5

4 d

. ~. _. ~...

1

..f.-

J

- DATA POINT LIBRARY REFERENCE FILE-Date:

1/15/92~

Reactor Unit:

PE2

. Data Feeder:

N/A NRC ERDS Parameter:

WIND DIR Point ID:

R006 Plant. Spec Point'Desc:

TOWEk 2 WIND DIR 320' Generic /Cond Desc.:

WIND DIRECTION hT THE REACTOR SITE Analog / Digital:

A

' Engr Units / Dig States:

DEG Engr Units Conversion:

IF GREATER THAN 360 SUBTRACT 360 FOR DIR Minimum Instr' Range:

O Maximum Instr Range:

540 Zero Point

Reference:

Reference = Point Notes:

PROC or SENS:

S' Number of' Sensors:

1 E"

How Processu'-

. Sensor Locations:

TOWER 2 320 FT ELEV.

Alarm / Trip-Set Points:.

NI-Detector Power.-Supply Cut-off Power Level:

NI-Detector Power Supply Turn-on. Power Level:

Instrument Failure Mode:

LOW Temperature Compensation For-DP Transmitters:

i Level Reference Leg:

- Unique System Desc.-

TOWER 2 WIND DIRECTION AT 320' ELEV.

WIND DIRECTION IS MEASURED "FROM" THE DIRECTION OF THE WIND.

DATA POINT LIBRARY REFERENCE FILE Date:

1/15/92 Reactor Unit:

PE3 Data Feeder:

N/A NRC ERDS Parameter:

EFF GAS RAD Point ID:

SPDS1588 Plant Spec Point Desc:

AVG VENT STACK RAD - NR or WR Generic /Cond Desc.-

RADIOACTIVITY OF RELEASED GASSES Analog / Digital:

A Engr Units / Dig States:

CPM Engr Units Conversion:

Minimum Instr Range:

10 4

Maximum Instr Range:

1 x 10 Zero Point Referer,ce:

Reference Point Notes:

PROC or SENS:

P Number of Sensors:

3 How Processed:

RANGE SELECTED AVERACE Senscr Locat'.ons:

NEAR TOP OF VENT STACK Alarm / Trip Set Points:

HIHI=100,000 CPM M1 Detector Power Supply Cut-off-Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

LOW Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc..

AVERAGE ROOF VENT STACK NR OR WR.

THIS RANGE SELECTED AVERAGE NORMALLY DISPLA'rS THE AVERg'GE OF TWO LOW PANGE (10 CPM - 10 CPM)

RADIATION MONITORS.

IF BOTH LOW

......~._.. _.......... _ -...

E

- i f

1 RANGEMONITORS'FAILORIFifENT STACK RAD LEVEL EXCEEDS 10 CPM.

THENTHEDISPL3YEDVALUEySFROMA HIGH RANGE (10 - CPM - 10 CPM)_

RADIATION MONITOR.

A SAMPLE OF VENT STACK DISCHARGE IS DRAWN FROM ISOKINETIC N0ZZLES LOCATED NEAR THE TOP OF THE VENT STACK.

b e

f d

8 4

t "t

i e

m---.-

- --+

~ ~

p 9%.-,5 yr

l DATA POINT LIBRARY REFERENCE FILE I

~

Date:

1/15/92 Reactor Unit:

PE3 I>ata Feeder:

N/A NRC ERDS Parameter:

WIND DIR Point ID:

R006 Plant Spec Point Desc:

TOWER 2 WIh'D DIR 320' Generic /Cond Desc.-

^

WIND DIRECTION AT THE REACTOR SITE Analog / Digital:

A Engr Units,/ Dig States:

DEG Engr Units Conversion:

IF GREATER THAN 360 SUBTRACT 360 EOR DIR Minimum Instr Range:

O Maximum Instr Range:

540 Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

S Number of Sensors:

1

]

How Processed:

Senscr Locations:

TOWER 2 320 FT ELEV.

Alarm / Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

Ni Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

LOW Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.-

TOWER 2 WIND DIRECTION AT 320' ELEV.

WIND DIRECTION IS MEASURED "FROM" THE DIRECTION OF THE WIND.

__