ML20098B780

From kanterella
Jump to navigation Jump to search
Rev 4 to Offsite Dose Calculation Manual
ML20098B780
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 08/31/1984
From:
MISSISSIPPI POWER & LIGHT CO.
To:
Shared Package
ML20098B759 List:
References
PROC-840831, NUDOCS 8409260264
Download: ML20098B780 (15)


Text

- .. _ - - . . . . -__ __

1 OETSITE DOSE CAICUIATICN MANIRL GRMO GHE NUCI"AR STATIM 4

j l

I 8409260264 PDR 840914 ADOCK 05000416 R

PDR GRAND GUIE, UNIT 1 Rev. 4 - 8/84

- - - - , , _ . , , , . , . m, .- , ,--. -~.wg..,~ .r,..y -w --m. - -w.,s w--

Revision No. 4 Date: July 30, 1984 GRAND GULF NUCLEAR STATION OFFSITE DOSE CALCULATION MANUAL SAFETY RELATED EVALUATION APPLICABILITY SAFETY EVALUATION ENVIRONMENTAL EVALUATION APPLICABLE APPL'ICABLE X NOT APPLICABLE X NOT APPLICABLE Reviewed / Approved:

up

,. f 6 4 [m/-//

sor, Environmental Services

/ f'-3o -di'/

Date Reviewed / Approve [/4/

(Jupervisor, Radiological Serfices

/ 7/86/MDate Reviewed / Approved: / O Manager, Radiological /{ Dafe Environmenta Ser i M Reviewed / Approved: ([>n / / }4

~nt, glea S ort Datef Vi{' Pre'si Reviewed / Approved:_ _- , / 7/f/ /[u '

CfiHi rman, r '

/Daty Plant Safety Review Committee Rev. 4 - 8/84 GRAND GULF, UNIT 1 1 17R2ay

ODCM LIST OF mn;nVE PAGES PAGE REN.

PAGE REV.

NO. NO. NO.

NO.

4l 1 4 2.0-22 1

  1. 2.0-23 2 11 2 2.0-24 2 iii 2 2.0-25 0 iv 2 2.0-26 3 v 1 3

vi 2 2.0-27 4 2.0-28 3 4l vii 2.0-29 3 1.0-1 0 2.0-30 3 2.0-31 0 1.0-2 2 0

1.0-3 2 2.0-32 2.0-33 0 1.0-4 1 0

1.0-5 0 2.0-34 1.0-6 1 2.0-35 4 l4 1.0-7 1 1.0-8 0 3.0-1 1 1.0-9 2 3.0-2 4 l4 1.0-10 0 3.0-3 3 1.0-11 0 3.0-3a 4 l4 3.0-3b 3 1.0-12 0 1.0-13 2 3.0-4 3 1.0-14 1 3.0-5 3 1.0-15 3.0-6 3 4l 4 3.0-6a 3 2.0-1 3 3.0-6b 3 2.0-2 3 3.0-6c 3 2.0-3 2 3.0-7 3 2.0-4 3 3.0-8 1 2.0-5 3 3.0-9 3 3.0-10 2 2.0-6 0 2.0-7 2 2.0-8 2 2.0-9 2 2.0-10 2 2.0-11 1 2.0-12 1 2.0-13 2 2.0-14 1 2.0-15 2 2.0-16 2 2.0-17 1 2.0-18 2 2.0-19 1 2.0-20 1 2.0-21 2 vii GRAND GUIE, UNIT 1 Rev. 4 - 8/84

* - I* .._. .

1.3 Liquid Radwaste Treatment Systan The essential ocmponents of the liquid radwaste treatment systan are 4 indicated below by an asterisk (*).

W -

nom 1 coserup l

{, g T== sen so ur Twas ,,

e

^* di 1-

- . - - . =~~ ~ c . ~u MTU (EMDG31MJ 8 DEL

e. Tasm8 e di N

S. REILIAfir M i C. MIT EREC g

'p

= mier

. m._d __ ,,,

Y" ,,

ip q,

" g " ,,,,u - 4 " ="n ,' - -.

"' E -.. agj'l=,,, C +

b- ====

==_ Nfr!!JJIM 10 til PURITT tafft

.v "

e oepow tesu susr= surmonfim suragesarre di IESIN usIENumTn. OEPOCAIA W ERmflGe 012JITim % _+ mg si EnJfrgan.e urt T o t

E Y 10 ELID af6W 0"" " -+ SmT E N t= -

m ,,,,,

D

. .....,,,=.

i NOI'ES

1. The essential ocuponents outlined above are those necessary to collect, process and sanple liquid radwaste prior to discharge to the environment.
2. Only one of the following is required in order to process liquid waste.
a. Equiptent drain filter
b. Floor drain filter
c. Equipmnt drain domineralizer
d. Floor drain demineralizer
3. One of the Waste Surge Tanks may be used to replace the Floor Drain Waste Collection Tank.

(A C014CN SYSTD4 SCALID 'IO A PER UNIT BASIS)

GRAND GUIE, UNIT 1 1.0-15 Rev. 4 - 8/84

1 l

2.5 GASEOUS.RAIA@STE TRFRNENT SYSTEM The instruments recpired to be checked by REIS 3/4.11.2.4 to ensure that the GASEQUS RADWASTE TRFMMENT (CETGAS) SYSTEM is functioning are:

1. Absorber train bypass switch (IN64-HS-M611) 4
2. Bypass valve indication (IN64-F045)

When the absorber train bypass switch is in the TRFAT position and the bypass valve indicates closed, the GASEQUS RADWASTE TREADENT (CETGAS) SYSTEM is functioning.

MAIN VENT BADNASTE BURDDG Hy 03 MD

CATAtYr1C BYPASS LDE -

IEIIPSINER 40 acfm M A ggg *^7 30 m orr cAs - wxo up F045 a"" zu'"

rum min camsoi ' n rzn - - - y c-=) ~

ses 4

HEPA ) EPA or i PUt LINIT) FILTUt F1133t Jb V no us BU11DDC vnnunzaN sysun NorE 4 1 The charcoal beds may be bypassed provided the limits of Itchnical Specification 3.11.2.1 are not exceeded. The charcoal beds will be used as noch as possible to ensure releases are as low as reasonably achiev-able. i l

l GRAto GULF, UNIT 1 2.0-35 Rev. 4 - 8/84 l

- - --. ~ -

s

  • I GXM TABLE 3.0-1
AIR SAMPIER COLIECTIN SITES AIR SAMPLERS
NLMBER FIGURE I4CNTIW 4
  • AS-1 PG 3.0-3 Southeast of GCNS at the Port Gibson City Barn.

(Sector G Radius 5.5 miles)

AS-2 61N 3.0-2 North Northeast of GGNS, on by 61 South across ,

f frcan the Yokena Church. (Sector B Radius 13 4

i miles)

  • AS-3 61 VA 3.0-2 North Northeast of GGNS on by 61 south at the Vicksburg Airport. (Sector E Radius 18 miles)

AS-4 G3W 3.0-1 Southwest of GGNS. Glodjo p un- ty on Waterloo l4 Road. (Sector L Radius .9 miles)

AS-5 TC 3.0-1 South of GGNS behind MP&L training center i building. (Sector J Radius .4 miles)

  • AS-6 PS 3.0-1 Northeast of GGNS, South of Grand Gulf Road. l4 4

(Sector C Radius .8 miles)

!

  • AS-7 Mr 3.0-1 North of GGNS, located next to the Meteorolo-i gical Tower. (Sector A Radius .8 miles) f l
  • AS-8 WR 3.0-1 East of GGNS, located at Maggie Jackson's l4 i

trailer on Waterloo Road near the Eastern Site

$ Boundary. (Sector E Radius .5 miles) l l AS-9 GG4P 3.0-1 North of GGNS, located in Grand Gulf Military l4 I Park. (Sector A Radius 1.5 miles) l AS-10 NLT 3.0-3 West Northwest of GWS, located at Newellton, Iouisiana. (Sector P Radius 12.5 miles) i, l AS-ll STJ 3.0-3 West Southwest of GWS, located at St. Joseph,

! Iouisiana. (Sector M Radius 13.0 miles)

!

  • Technical Specification requirments I

Frczn Grand Gulf Nuclear Station's Annual Radiological Enviromental

Operating Report.

t l,

i GRAND GUIF, WIT 1 3.0-2 Rev. 4 - 8/84

QXM TABLE 3.0-2 (CCNTINUED)

Page 2 of 3 SUMACE WNTER Upstre m

  • 4500 ft. upstream of the Gas outfall to allow adequate mixing of the Mississippi and Big Black Rivers. (Sector Q)

Downstream

  • 3.0-4 5000 ft downstream of G WS cutfall, near the most southern ram al well. (Sector N)

Discharge Basin

  • 3.0-4 West of GNS, 0.5 miles, Sector P VEGETATIN Broad leaf Vegetation
  • 3.0-4 South of GGNS near the training center (Sector J, 0.4 miles) and North Northwest of G WS near 4 the Meteorological 'Ibwer (Sector R, 0.8 miles) ,

l4 Alcorn State University South-west of GGNS (Sector K,10.5 miles)

FISH SAMPLES Camercially or 3.0-4 Downstream of the discharge recreationally inportant point in the Mississippi River 4 species

  • 3.0-4 Upstream of Discharge Point uninfluenced by Plant Operations.

GRAND GULF, UNIT 1 3.0-3a Rev. 4 - 8/84

- - - ' =

_ .m,_ e. ,

, . 1 l

I

. . l i

f 1

CETSITE DOSE CAICULATICN MPNUPL GWO GHE NUCEAR SIATICH WaP -

e en O

4 l .

GRAND GHE, UNIT 1 Rev. - 4 48

. . e . .

h Revision No. [Y Date 4M4 GRAND GULF NUCLEAR STATICE OFFSITE DOSE CAICUIATICE MANUAL SAFEIY REEATED EVA111ATION APPLICABILITY SAFETI EVALUATICN DNIRCNMENTAL EVALUATICN APPLICALLE APPLICABLE X Nor APPLICABLE X NOT APPLICABLE Reviewed / Approved: - j..m-O 4 --- $/lf/g IvtsoQpf' Environmental Services /Date Reviewed /Appr . _M[M*mLy - -

pupeIvisol pf Radiological !EWices/cate Reviewed / Approved: ~ f /O Managerpf' j Radiol 1 & Environtrental Services /Date Reviewed / Approved: --

A p.- / Ye /[f ((

3 "'MEI -O 4'"C1 ' ^WI /Date i Reviewed / Approved: _

g 1ritan, P1[t Sa ~MW ety Beview Cmnittee/Dats 9Mg/

' /

e dS en tY2r ear & l 1 .

'l GRAND GUIE, UNIT 1 Rev. -

8/87 v- - -

CDCM LIST T EETECTIVE PAGES J PAGE REV. ,

PAGE REV. (

NO. NO. NO. NO. l l i 11

((

2 2.0-22 2.0-23 1

2 iii 2 2.0-24 2 iv 2 2.0-25 0 v 1 2.0-26 3 vi 2 2.0-27 3

- p[l vii #/ 2.0-28 2.0-29 3

3 1.0-1 0 2.0-30 3 1.0-2 2 2.0-31 0 1.0-3 2 2.0-32 0 1.0-4 1 2.0-33 0 1.0-5 0 2.0-34 0 1.0-6 1 2.0-35 (( l[p 1.0-7 1 -

1.0-8 0 3.0-1 1 1.0-9 2 3.0-2 ff /

1.0-10 0 3.0-3 3 1.0-11 0 3.0-3a ,7/ p 1.0-12 0 3.0-3b 3 1.0-13 2 3.0-4 3 1.0-14 3.0-5 3 # V

/l 1.0-15 [1 I 3.0-6 3.0-6a 3

3 g u 2.0-1 2.0-2 3

3 3.0-6b 3.0-6c 3

3 2.0-3 2 3.0-7 3 y s 2.0-4 3 3.0-8 1 2.0-5 2.0-6 3

0 3.0-9 3.0-10 3

2 M

2.0-7 2 2.0-8 2 2.0-9 2 2.0-10 . 2 2.0-11 1 2.0-12 1 2.0-13 2 2.0-14 1 2.0-15 2 2.0-16 2 2.0-17 1 2.0-18 2 2.0-19 1 2.0-20 1 .

2.0-21 2 vii l GRAND GUIE, UNIT 1 Rev. [ 84

Y B r - - -

1 1.3 Liquid Radwaste Treatnent system

'the essential mp.snts of the liquid radwaste treatment systanW 3/.11.1.0 are indicated

" a;=2""' rigi_.a.; cf .L.; ;-- ifi ti

- below by an' asterisk (*) .

sm. 964_

1 seen.J
1 g
_

g, EE.--+

e,=

F -

q ,

_"""'". u o

=

- - = ~ c.; == ,u ..

.\- ===u=.

e 4 _~==T < -

= ",_

m

' g..A.=u===. _- .a *." " . , , , , o m 1

n

.. mn na " o L'"*

v o

  • o s.

3.

. T , = M u vn . = =

,,,m,, ,, ,,.

. m ==

  • o o :M

_ L _i_

o

, ~, e_; e.,... =="=

c

. == i "

.. ,JaaP-t. = a = = . ;

c = =. = ==

. . = 2

. == sinnua . m susm as:x>smat,3 F amarenarse I

~ =="-

=' 7 ti ,,,._

7"'""* " t w saa men

_e=r- =us an. j , ue o=c h ""** + oen om 1888

SAEER>

~

I g=

V.._

FEES'Ihe essential otrponents outlined alvve are those necessary to collect,

~1.

process and sanple liquid rachiaste prior to discharge to the en

2. Only one of the following is required in order to process liquid wast
a. Equi p nt drain filter
b. Floor drain filter
c. Equiptent drain denineralizer
d. Floor drain donineralizer

' 3 One of the War e Surge Tanks snay be used to replace ..

the Floor Dr Collection Tan'.

' (A CGliCN SYSDM SCALFD 'IO A PER (N1T BASIS) y 9 1.o-15 nev. f - f/84 canso outr, unir 1

. . . _ -. _. . .- 1_._________._

2.5 GASECUS RADWASTE TRCMMENT SYSTEM ffg/ / 4 O.; er- .tial = 7:-ets rf th: C.*i

.iss ' ::'" 'h % 2?? " " ; q b .; ef l'su s.,

m a , 7 m O T ' rz)*

^Lii=T'= L 3/4.11.2.t = i 'ix'd b
L~ b; : . ::^aisk '*; .C INS &S*T ELT.DDC
  1. =*

m o, 2

CATALYT:C -= _ .;

-tm

-.- g u m so aa. n L",

2% =

,L*

l 7045 , - y

--- o -

owcw. __ _

( am:m 3 _

~

aus

,m,% =AW mcJt.

ar i e am ru m rn.m a

&J snm wm 3 m.r.zoc m tm sme

~

M/ The-essent i al-<wponents-included-above-are-those-nece

-1. s sary-te

-process gaseous-rakaste-prior-to dischargedo-the envitunment&

T!w charcoal beds noy be laqussed provided the limits of Tec!mical Specification 3.11.2.1 are not exceeded. The ci arcoal bt* will be used as nuch as possible to ensure releases are as low as reason-ably achievable, f 8 ceno ans, UNIT 1 2.0-35 pcv.J'-//84

Insert A to Section 2.5 Gaseous Radwaste Treatment System Page 2.0-35 The instruments required to be checked by RETS 3/4.11.2.4 to ensure that the GASE0US RADWASTE TREATMENT (0FFGAS) SYSTEM is functioning are:

1. Absorbertrainbypassswitch(IN64-HS-M611)
2. Bypassvalveindication(IN64-F045)

When the absorber train bypass switch is in the 1REAT position and the bypass valve indicates closed, the GASEOUS RADWASTE TREATMENT (0FFGAS)

SYSTEM is functioning.

l 29Eay

COO 4 TAB C .0-1 AIR SAMP!ZR mrmTIcN SI'133 AIR SAMP!DS -

ulteER FIGURE 10 CATI N

  • AS-1 PG 3.0-3 Southeast of G34S at the Port nn-i City Barn. 3 (Sector G Radius 5.5 miles)

AS-2 61N 3.0-2 North Northeast of GGNS, on &#y 61 South across 3 frcm the Yokana O urch. (Sector B Padius 13 miles)

  • AS-3 61 VA 3.0-2 North Northeast of GGNS on Ery 61 south at the Vicksburg Airport. (Sector B Badius 18 miles)

[AS-4 GJE 3.0-1 Sout N est of G @S. Glodjo property on Waterloo Road. (Sector L Radius .9 miles)

AS-5 'IC 3.0-1 South of GGNS behind MP&L training cantar 3 building. (Sector J Radius .4 miles)

  • AS-6 RS 3.0-1 Northeast of GGNS, South of Grand Gulf Road.

(Sector C Radius .8 miles)

  • AS-7 Mr 3.0-1 North of GGNS, located next to the Meteorolo- 3 gical 'Iber. (Sector A Badius .8 miles)
  1. AS-8 WR 3.0-1 East of GGNS, located at Maggie Jackson's trailer on Waterloo Road near the Eastern Sita Boundary. (Sector E Radius .5 miles) 3

[AS-9 GCMP 3.0-1 North of G@S, located in Grand Gulf Military .

Park. (Sector A Radius 1.5 miles)

~

AS-10 NLT 3.0-3 West NortNest of G@S, located at Newe11 ten, Iouisians. (Sector P Radius 12.5 miles)

AS-11 6TJ 3.0-3 West Southwest of CGS, located at St. Joseph, louisiana. (sector M Radius 13.0 miles)

'

  • Technical Specification requirenents
  • Frca Grand Gulf Nuc1 car Station's Annual Radiological Dwiromental 3 Operating Retort.

l ..

V 8 GPN O GMF, UNIT 1 3.0-2 Rev. [-//84

. . - _- _ .-. m _. . ___ __ __

b..

N I TABLE 3.0-2 (CCNTINUED) l Page 2 of 3 SUlfACE WNPER r*iqure Upstream

  • 3.0-4 4500 ft. upstream of the GGNS 13 outfall to allow adequate mixing of the Mississippi and Big Black Rivers. (Sector Q)

Downstream

  • 3.0-4 5000 ft. downstrean of G2S l3 outfall, near the most southern radial well. (Sector N)

Discharge Basin

  • 3.0-4 West of GGNS, 0.5 miles, Sector P VEGE?rATICE Broad Imaf Vegetation
  • 3.0-4 South of GGNS -6st-th: ""C ga.O."

near the training center p ~

-Gouth h t.h ;L in 01 @ *=

y den,-a; are.as ad W A t: --

-tt--- ~~@a~ (Sector J, 0.4 miles)7 QAllNYkY&sf WWWE b$ $

~ dd A%A icJ& f .

. -~- . Tr_n .. . .

..-- - . _, ~ . . . , -

Seck f 68 5 Alcorn State University South-west of GGNS (Sector K,10.5 3 miles)

FISH SAMPLES

--Catfish # 3.0-4 Downstream of the discharge point in the Mississippi River 4* ex_/4/ er 3.0-4 Upstream of Discharge Point uninfluenced by Plant j Nea;dJa < ,-;[ Operations.

l' Q

/ t*cier

  • Technical Specification requirements Frtin Grand Gulf Nuc1 car Station's Annual Radiological Environmental Operating Peport. l3 Y 8 GRAND GUIF, UNIT 1 3.0- 3a FeV. -

84

_ ,