PHILADELPHIA ELECTRIC COMPANY 2301 MARKET STREET P.O. BOX 8699 1881 1981 PHILADELPHIA P A.19101 AUG 241984

'2isi 84i.4 so 2

- s. x m,.

V IC E-PR ESI D E NT Suenta mens Asso atstamue Dr. Thcmas E. Murley, Director United States Nuclear Regulatory Comission Office of Inspection and Enforcermnt, Region I 631 Park Avenue King of Pn:ssia, PA 19406

Subject:

Significant Deficiency Report No. 145

)

Material Furnished Without the Chemical Overcheck j

Requirement of Paragraph NCA-3867-4 (e) (2)

Limerick Generating Station, Unit 1 Attachments:

letter: Guyon Alloys Inc. to the Bechtel Power Corporation Dated 05/24/84 File:

QUAL 2-10-2 (SDR #145)

Dear Dr. Murley:

The attached letter has brought to our attention the problems of sane material being furnished to Limerick Generating Station with incanplete docunentation and lacking the chenical overcheck requirement of paragraph NCA3867.4 (e) (2). This deficiency has previously been reported to the USNRC by Guyon Alloys Inc. under the provisions of 10CFR21.

We consider the deficiency described in the attachment as a significant deficiency per 10CFR50.55(e) and are hereby notifying you as required.

We believe that the Guyon Alloys Inc. 10CFR21 notification letter to Bechtel Power Corporation (Agent to PECO) provides the information required for 10CFR50.55(e) reporting.

Therefore, we anticipate that this letter will be our only report to you on this subject.

We have completed our investigation into this matter and have determined that there is no objective evidence to show that any of the six (6) weldolets in question have been installed in the Limerick Generating Station.

Sincerely, WSS/drdO8208401 dENd Attachment Copy to: Director of Inspection and Enforcement United States Nuclear Regulatory Ccumission Washington, DC 20555 S.K. Chaudhary, Resident NRC Inspector (Limerick)

J.

Wiggins, Resident NRC Inspector (Limerick) 8409210347 840824

\\

PDR ADOCK 05000352

\\

S PDR jf. Al f

t

\\

l L

IE eg.

GUYUN TUBULAR PRODUCTS FOR THE ENERGY INDUSTRES i

l 950 South Fourth Street, Harrison, N.J. 07029 (201) 485 5050 May 24, 1984 BIchtel Power Corporation Agent for Philadelphia Electric Co.

P.O. Box A, Sanatoga Branch Pottstown, Penna.

19464 Attn:

Mr.

Drew Krapf

Subject:

Orders No. 8031-F-50970 8031-F-56377 Limerick Generating Station 10CFR21 Notification Pursuant to the notification requirements of the Code of Federal Regulations Title 10, Part 21 (10CFR21) per attached copy Guyon Alloys has received a notification from the Bonney Forge-Gulf & Western Manu-facturing Company advising that some material shipped from their Carlinville, Illinois plant has been furnished to Guyon Alloys with incomplete documentation and lacking the chemical overcheck require-m:nt: of Para. NCA-3867.4(a)(2).

Based on a thorough review of our records in conjunction with the msterial listing received with the Bonney Forge notification, some of tha items of material cited by Bonney Forge have been identified as hcving been in turn furnished by Guyon Alloys against the subject order (s) for the referenced p'roject.

The items so identified are listed on attached " Exhibit I.

As discussed in the attached copy of our return letter to Bonney Forge, it is suspected that the identified items have been manufactured from unqualified stock material which was incompletely or improperly qualified (upgraded) under the provisions of NCA-3867.4(e) or NA-3767.4(e) cs and if applicable.

Additional detailed information as requested by our letter will be relayed to you upon receipt from Bonney Forge.

In as much as Guyon Alloys as a material supplier does not have the ccpability of determining whether the use of the discussed material as furnished may create a substantial safety hazard, this notification and tho add 1.tional information to follow is being provided to facilitate l

your such determination.

l

o 4

I p

GUYON ALLOYS,IE eg TUOULAR PRODUCTS FOR THE ENERGY INDUSTRES 950 South Fourth Street, Harrison, N.J. 07029 (201) 485-5050 Please note that under the size / quality program exclusion provi-sions of Paragraph N(x)-2610 per the 1974 Edition / Winter 1975 Addenda cnd later Edition and/or Addenda of ASME Section III, it may be pos-sible to consider 2" nominal pipe size or smaller fittings as :.isted on Exhibit I acceptable as furnished.

For such fittings procured to an earlier Code Edition and/or Addenda, the use and acceptance of the size / quality program exclusion provisions per a later Code Edition and Addenda may be necessary.

Please advise Guyon Alloys of the results of your determination of whether the use of the fittings as furnished would create a: sub-senatial safety hazard, the status, and any proposed disposition of tho fittings involved.

Very truly yours, GU'f0NALLbINC

.s/ t!/

George H. Grunthaler Vice President Technical Services

dMY65N ALL@YS*, INC.

I EXHIBIT I

Orders No.

8031-F-50970 8031-F-56377 Purchaser:

Bechtel Power Corporation Agent for Philadelphia Electric Co.

Proj ect:

Limerick Generating Station Philadelphia Electric Co.

Order 8031-F-50970 SA-182 Grade F316L, ASME Section.III Class-1, 1980 Edition /

Winter 1981' Addenda' Item fl.

3 pes. 6" Sch. 80 x 3/4" Sch.40 Weldolets, Bonney Forge Heat Code 482B Date shipped:

6/15/82 (G/A A-52155-NW) 4 i

Order 8031-F-56377 SA-182 Grade F304L, ASME Section III Class 1, 1980 Edition /

j Sunner 1982 Addenda'

]

Item #1.

3 pes. 4" x 2" Sch. 80 Waldolete, Bonney Forge Heat Code 653B Data shipped:

12/23/82 (G/A A-62803-NW) l l

l t

e QO9 1