'4 WISCONSIN-ELECTRIC POWER COMPANY 1
1 DDCKET NO. 50-261 POINT BEACH NUCLEAR PLANT. UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICEES{
Amendment No.132 License No. DPR-24.
1.-
T!.e Nuclear Regulatory Commission (the Commission) has found that:
i A.
The application for amendment by Wisconsin Electric Power Company (the licensee) dated August 9, 1991, complies with the standards and
't requirements of the Atomic Energy Act of 1954, as amended (the Act),
and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.'
The. facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the 7
Commission; C.
Therelis reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted I
in compliance with the Commission's regulations; t
D.
The' inuanceLof this amendment will not be ininical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have -
been satisfied.
t
}
r 9206170'161 920610 PDR ADOCK 05000266 P
~
.-.-u..-.-
l
. 2.
Accordingly, the license is amended by changes to the Tech.11 cal Specifications as indicated in the attachment to this license amendment, and paragraph 3.B of Facility Operating License No.
DpR-24 is hereby amended to read as follows:
B.
leghnical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.132, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective immediately upon issuance.
The Technical Specifications are to be implemented within 20 days from the date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION f
/.)
aH Robert B. Samworth, Sr. Project Manager Project Directorate 111-3 Division of Reactor Projects lil/IV/V Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of issuance: June 10, H92
O ctco
?
/
P UNITED STATES
{,
2: n,i NUCLEAR REGULATORY COMMISSION o
WASHWoTON. D C. 72
- ...+
l KlSCONSIN ELECTRIC POWER COMPANY DOCKET NO. 50-lQ1 POINT BEACH NUCLEAR PLANT. Uffli NO. 2 LMENDMENT TO FACILITY OPERATING LICENSE Amendment No.136 License No. DPR-27 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Wisconsin Electric Power Company (the licensee) dated August 9, 1991, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),
and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (1) that the ar.tivities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordante with 10 CFR Part 51 of the Commission's regulatioL end all voliNbie requirements have been satisfied.
1
2.
Accordingly, the license is amended by changes to the lechnical Specifications as indicated in the attachment to this license amendment, and paragraph 3.B of Facility Op3 rating License No.
DPR-27 is hereby amended to read as follows.
B.
Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.136, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective immediately upon issuance. The Technical Specifications are to be implemented within 20 days f rom the date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION Y-kw Robert B. Semworth, Sr. Project Manager Project Directorate 111-3 Division of Reactor Projects Ill/IV/V Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of issuance:
June 10, 1992 i
(
ATTACHMEtiT 10 LICEt1SE AMENPfMEtiT N05.132 At10136 TO FACILITY OPERATlfiG LICENSE tiOS. DPR-24 AND DPR-27 DD[KET I405. 50-266 AND 50-391 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the enclosed pages.
The revised pages are identified by amendment number and contain marginal lincs indicating the area of change.
REMOVE
.11($181 15.4.6-1 15.4.6-1 4
su
15.4.6 EMERGENCY POWER SYSTEM PERIODIC TESTS A plicability.
J Applies to periodic testing and surveillance requirements of the emergency power system.
O_bjective To verify that the emergency power system will respond promptly and properly when required.
Sp_ecification The foilowing tests and surveillance shall be porformed as stated:
A.
Diesel Generators 1.
Manually-initiated start of the diesel generator, followed by manual synchronization with other power sources and assumptien of load by the diesel generatur shall not exceed 2850 KW.
This test will be conducted monthly with a minimum running time of 30 minutes on each diesel generator.
Normal plant operation will not be affected.
2.
Automatic start of each diesel generator, load shedding, and restore-tion to operation of particular vital equipment, initiated by an actual interruption of normal A-C c.ation service power supplies to associated engineered safety systems busses together with a simulated safety injection signal.
In addition, after the diesel generator has carried its load for a minimum of 5 minutes, automatic load shedding and restoration of vital loads are tested again by manually tripping the diesel generator output breaker.
This test will be conducted during reactor shutdown for major fuel reloading of each reactor to P a that the diesel-generator will start and assume required '
a in accordance with the timing sequence listed in FSAR Section 8.2 after the initial starting signal.
During this test a checkout of emergency lighting will be performed, including the changeover relay for DC lights.
Point Beach Unit 1 Amendment No. A7,97,132 Pcint Beach Unit 2 15.4.6-1 Amendment No. E2,95,136