_

O e

Chapter 6.

PTS Integrated Risk for Calvert Cliffs Unit 1 and Potential Mitigation Measures of A PRESSURIZED THERMAL SHOCK EVALUATION OF THE CALVERT CLIFFS UNIT 1 NUCLEAR POWER PIANT P r. s l

.3 II a jj L,_] jf written by The PTS Study Group of Oak Ridge National Laboratory By acceptance of this article, the pubbsher or recipient acknowledg.s the U.S. Government's right to reteen a nonesclusive, royalty-free I. cense 6n and to any copyright co reng the.,tici..

s Date of Draft: August 21, 1984 NOTICE: This document contains.Information of a preliminary nature.

It is subject to revision or correction and therefore does not represent a final report.

  • Research sponsored by U.S. Nuclear Regulatory Commission under Contract No. DE-AC05-840R21400 with the Martin Marietta Energy Systesse Inc.

with U.S. Department of Energy.

1 1

l l

I l

l 8409190212 840828 i

PDR ADOCK 05000317 l

P PDR

-.