.w-PHILADELPHIA ELECTRIC COMPANY 23O1 MARKET STREET P.O. BOX 8699 PHILADELPHIA. PA.19101 JOHN S. KEMPER
.-. 0'JffIn 11..
SEP 071984
'Mr. A. Schwencer, Chief.
Docket No.:
50-352 Licensing Branch No. 2 U. S. Nuclear Regulatory Cm mission Washington, D.C. 20555
Subject:
Limerick Generating Station, Unit 1 Request for Additional Information frta NRC Materials Engineering Branch (MTEB)
SER Confirmatory Issue No. 22 Referen s:
(1) 9/4/84 Telea:)n betweer. W. Hazelton, NRC/MTEB, R. E. Martin, NRC/DC, and J. T. Robb, et. al. PECO.
(2)
Letter frcan J. S. Kmper to A. Schwencer dated Septenber 6, 1984.
Dear Mr. Schwencer:
This letter' confirms cmmitments riade during the reference telecon.
PECO will provide an augmented inservice inspection program for the Limerick Unit 1 outboard feedwater check valves (1F074A and 1F074B valves).
This inspection program will be inplemented at the first refueling outage.
It will include a visual examination of the entire
. surface of the valve bodies, both internal and external.
The inspection program will, after appropriate surface preparation, be of sufficient sensitivity to detect a minimum crack length of 335 inches.
'Ihis is equivalent to the conservative crack size assumed in the fracture mechanics analysis provided via the reference 2 letter.
Inspections subsequent to the first refueling outage will be in accordance with the Unit 1 ISI program.
The augmented inspection program will be fu*Jier described in the ISI program for Limerick Unit 1.
The ISI program will be submitted for NRC evaluation 6 months after camercial operation as required by SER confirmatory issue 12.
We trust ' this information is sufficient to close confirmatory issue no. 22.
Sincerely, 8409140162 840907 PDR ADOCM 05000352 p'l E
PDR HDH/gra/09058402 cc: Sce Attached Service List
v-
,,.,?
cc: Judge Lawrence Bremer Judge Peter A. Morris-
~ Judge Richard F. Cole Judge Christine N. Kohl
^
Judge Gary J. Edles l
Judge Reginald L.'Gotchy l
Troy B. Conner, Jr., Esq.
Ann P. Hodgdon, Esq.
Mr. Frank R. Romano
>Mr. Robert L. Anthony Ms. Maureen Mulligan Charles W. Elliot, Esq.
Zori G. Ferkin, Esq.
Mr. T!cmas Gerusky Director,. Penna. Emergency Management Agency Angus R. Love, Esq.
David Wersan, Esq.-
Robert-J. Sugarman, Esq.
Martha W. Bush, Esq.
Spence W.' Perry, Esq.
Jay M. Gutlerrez, Esq.
- f. -
Atomic Safety & Licensing Appeal Board Atomic Safety & Licensing-Board Panel Docket & Service Section p
-Mr. James Wiggins j'
Mr. Timothy R. S. Campbell
__ _ _ - - _ _ _ - -. _ - -