Northem States Power Company 414 Nicollet Mall Minneapolis, Minnesota 55401 1927 Telephone (612) 330-5500 st May 14, 1992 Monticello Technical Specifications Section 6.7.A.3
,,US Nuclear, Regulatory Commission j; Attnr Document, Control; Desk '
~ WashingtonDC ~~ 20555 ;'
MONTICELLO NUCLEAR GENERATINC PLANT Docket No. 50-263 License No. DPR-22 Monthly Operating Report Anril. 1992 Attached is the Monthly Operating Report for April, 1992 for the Monticello Nuclear Generating Plant.
[
/84 M6
' Thomas M Parker Manager Nuclear Support Service MP/mkl C:
Director, Office of Resource Management Regional Administrater-111, NRC NRR Project Manager, NRC NRC Resident Inspector State of Minnesota - Kris Sanda Attachment I
\\i V
190010 9
s 9205190009.920430 A
PDR ADOCK 05000263 R
OPERATING DATA REPORT DOCKET NO.
50-263 DATE 5-4-92 COMPLETED BY H.
H. Paustian TELEPHONE 612/295-5151 OPERATING STATUS
) Notes
]
- 1. Unit Name :
Monticello
]
]
- 2. Reporting period:
APRIL
]
]
- 3. Licensed Thernal Power (MWt) : __
1670
)
]
- 4. Nameplate Rating (Gross MWe):
569
)
]
- 5. Design Electrical Rating (Net MWe):
545.4
)
)
- 6. Maximum Dependable Capacity (Gross MWe): __564
)
)
- 7. Maximum Dependaole Capacity (Net MWe):
536
)
)
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons:
- 9. Power Level To Which Restricted, If Any (Net MWe):.__N/A
- 10. Reasons For Restrictions, If Any: __N/A THIS MONTH YR.-TO-DATE CUMULATIVE
- 11. Hours In-Reporting Period 719 2903 182640
- 12. Number Of Hours Reactor Was Critical 570.2 2685.3 146103.7
- 13. Reactor Reserve Shutdown Hours 0.0 0.0 940.7
- 14. Hours Generator On-Line 550.5 2647.3 143395.2
- 15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
- 16. Cross Thermal Energy Generated (MJH) 903998 4382148 219915725
- 17. Gross Electrical Energy Generated (MWH) 302835 1474849 74364694
- 18. Net Electrical Energy Generated (MWH) 290774 1418420 71120638
- 19. Unit Service Factor 76.6%
91,2%
78.5%
- 20. Unit Availability Factor 76.6%
9'.2%
78.5%
- 21. Unit Capacity Factor (Using MDC Net) 75.5%
91.2%
72.6%
- 22. Unit Capacity Factor (Ucing DER Net) 74.2%
89.6%
71.4%
- 13. Unit Forced Outage Rate 0.0%
2.5%
3.9%
- 24. Shutdowns Scheduleu Over Next 12 Months (Type, Date, and Duration of Each)
- Refueling Outage - 1/6/93 - 56 days
- 25. If Shut Down At End Of Report Period, Estimated Date Of Startup:N/A
- 26. Units In Test Status (Prior to Commercial Operation): N/A Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION l
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
50-263 UNIT Monticello.___
DATE 5-4-92 COMPLETED BY H.
H. Paustian TELEPHONE 612/295-5151 MONTH OF APRIL DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net) 1 540.
17 539.
'2 542.
18 539.
3 541.
19 352.
4 537.
20
- 6. __,
5
- 541, 21
-4.
6
- 542, 22
-4.
7 542.
23
-4.
8 539.
24
-4.
9 539.
25
-4.
10
- 542, 26
-4.
11
- 544, 27 486.,
12 538.
28 534.
13 537.
29 534.
14 541.
30 537.
-15 540.
16 541.
INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.
Compute to the near:est whole megawatt.
DOCKET NO.
50-263 DATE 5-4-92 COMPLETED BY H.
H.
Paustian TELEPHONE 612/295-5151 MONTH _
__.APR 4-1-92 to Power operation.
4-19-92 4-19-92 Emergency Diesel Generator maintenance outage to replace to improperly torqued rotor pole piece hold-down bolts due to 4-26-92 manufacturer procedural problems during originel cerstruction.
4-26-92 to Power operation.
4-30-92 Note: Power operation defined as essentially 100% of rated power except for weekend load drops for c
specified surveillance testing.
yi,
,,.e UNIT ShVIDOWNS AfD PCMER REDUCTIOtB -
DOCFRP 10.
50-263'
~'.
UNIT IME ticello DATE 5-01-92 CMPIETED BY
. H. Paustian-
' REPORT !Otml April TELEPHCflE,,612/295-51ST '
Ib.
Ihte T'/ne Duration Reason Method LER System Cause & Qorrective' tl)
(hours)
(2)
.of No.
Code'
-C e
Action to Shutdown
.(4):
(5)
Prevent Recurrence' (3) 4- 04-19-92 S
168.5 B
1 N/A-EK DG Maintenance Qutage to replace inprocerly torqued :
rQtor pole piece hold-down bolts du to Drergency-Diesel Generator manufacturer procedural problems.
1 2-3 4
i F: Forced Reason:
Method:
Draft IEEE Standard S: Scheduled A-Equignent Failure (Explain) 1-Manual 805-1984(P805-DS)
B-Maintenance or Test 2-thtual Scram C-Refueling 3-Automatic Scram 5
D-Regulator Restriction.
4-Other.(Explain)
IEEE Standard 803A-1983 E-Operator Training & License Examination F-Administrative G-ratlonal Error-(Explain)
H-O r (Explain)
1.
ll I
Y Duke thun Company Hachovia Center PO ikuc IMi Charlotte, N C 2001 1007 May 13, 1992 U.S. Nuclear Regulatory Comission ATTENTION:- Document Control Desk Washington, D.C.
20555 RE: Catawba Nuclear Station Docket No. 50-423 and 50-414 File: GS-801.01
Dear Sir:
Please find attached information_concerning the performance and operating status of the Catawba _. Nuclear Station for the month of April,1992.
Also attached is a REVISED copy of the Unit Shutdowns and Power Reductions pages for Catawba 1.for the Month of March, 1992.
Very truly yours, h h.
E..0. McCraw, Manager.
Operations, Perfomance, & Automation EOM/sdg Attachments:
xc: Stewart D.-Ebneter
-Richard G. Oehl, NE-44
- Regional Administrator / Region II U.S. Department of Energy U.S; Nuclear Regulatory Commission 19901 Germantown Rd.
101 MariettaiSt.,-NW, Suite 2900 Germantown, MD 20874 Atianta, GA 30323-Bob Martin INPO Records Center Office Nuclear Regulation 1100 Circle 75 Parkway, Suite 1500 U.S. Nuc.: Reg. Commission Atlanta, GA 30323 Washington, D.C.
20555 Ms. Vicki White
- American Nuclear Insurers Nuclear Assurance Corp.
c/o Dottie Sherman, ANI Library 6251 Crooked Creek Road The Exchange, Suite 245-Norcross, GA 30092 l'
270 Farmington Ave.
Farmington, CT 06032 W. T. Orders I
Senior Resident Inspector Catawba Nuclear Station p
k
/)\\,
fon tin o I
e9205190095 920c13
. DR ADOCK 0500 3
I
.