ML20096D410

From kanterella
Jump to navigation Jump to search
Rev 1 to 920327 Application for Amends to Licenses DPR-77 & DPR-79,changing TS to Increase Spent Fuel Pool Storage Capacity,Clarifying Matl Column in TS Table 6.5.1 & Changing Value of E in Equation Re Vertical Compressive Strength
ML20096D410
Person / Time
Site: Sequoyah  Tennessee Valley Authority icon.png
Issue date: 05/11/1992
From: Burzynski M
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20096D413 List:
References
CON-TVA-SQN-TS-92-01, CON-TVA-SQN-TS-92-1 NUDOCS 9205180029
Download: ML20096D410 (2)


Text

.-

k tevieme voy sumur noi uve smt cwrcua te wwee 37o2 MAY 111392 TVA-SQN-TS-92-02 10 CFR 50.90 N

V.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, DC 20555 Gentlemen:

In the Matter of

)

Docket Nos. 50 327 Tennessee Valley Authority

) _

50-328 SEQUOYAH NUCLEAR PLANT (SQN) - REVISION 1 TO ENCLOSURE 2 0F REQUEST FOR LICENSE AMENDMENT TO TECHNICAL SPECIFICATION (TS) - SPENT-POOL STORACE CAPACITY INCREASE The enclosed pages reflect revisions to the subject licensing..mendment request submitted on March 27, 1992.

Please ma:e the appropriate changes as indicsted below.

1.

Page 6-43:

(;1arification made under lialarial column in both sections of Table 6.5.1.

The value for Young's Modulus of Elasticity, E.

(psi), was also changed in all three places.in the second column from 27.9 x 106 to 27.6 x 106 to reflect the value at 200*F rather-than 150*F.

2.

Page 7-3:

Tha value of E was changed'to 27.6 x-106 in the ninth line of the second paragraph.

In the equation for the limiting vertical compressive stress, 6cr, at the beginning of the third paragraph, the value has been changed from 14,387 psi to 14,232 psi.

3.

Page 7-4:

In the sixth line under Section 7.4, a parenthetical insert was added to indicate the use of SA 36 material for the. impact shield.

4.

Page 7-6:

The maximum veld shear stress, rmax, was changed from 15,684 to 15,515 psi, to reflect the previously mentioned al percent change.in E.

These revisions were discussed with morrhers of your staff on April 23, 1992, and do not have significant-effect on any previous analysis or calculation performed.

I f

\\,

q P

l A

m

~

I U.S. Nuclear Regulatory Commission Page 2 MAY 11932 Please direct questions concerning this issue to C. R. Davis at (615) 751-7509.

Sincerely, N

4 9

4 s

l ski Mark rz Managdk Nuclear Licensing und Regulatory Aff airs Enclosures cc (Enclosures):

Mr. D. E. LaBarge, Project Manager U.S. Nuclear Regulatory Comn.it sion e White Flint North 555 Rockville Pike Rockville, Maryland 20852 Mr. Michael 11.- Mobley, Director (w/o Enclosures)

Division of Radiological liealth T.E.R.R.A. Building 150 9th Avenue, N Nashville, Tennessee 37203 NRC Resident inspector

(

Sequoyah Nuclear Plant 2600 Igou Ferry Road Soday Daisy, Tennessee 37379 Mr. B. A.-Wilson, Project Chief U.S. Nuclear Regulatory Conmission Region II

?01 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 i

2