Amend 174 to License NPF-6,revising Surveillance Requirements Re Main Turbine Steam Valves
ML20095K283
Person / Time
Site: Arkansas Nuclear 
Issue date: 12/22/1995
From: Kalman G
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20095K286 List:
References
NPF-06-A-174 NUDOCS 9512280223
Download: ML20095K283 (5)


Text

_ _....

pt4 Mu s

UNITED STATES p

s j

NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. =a =1

'+9.....

o ENTERGY OPERATIONS. INC.

DOCKET NO. 50-368 ARKANSAS NUCLEAR ONE. UNIT NO._1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.174 License No. NPF-6 l

1.

The Nuclear Regulatory Commission (the Comission) has found that:

A.

The application for amendment by Entergy Operations, Inc. (the licensee) dated April 4,1995, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance:

(i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this license amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements 4

have been satisfied.

i 3

4 t

9512280223 951222 PDR ADOCK 05000368 P

PDR

}

s l 2.

Accordingly, the license is amended by changes to the Technical i

Specifications as indicated in the attachment to this license amendment, and Paragraph 2.C.(2) of Facility Operating License No. NPF-6 is hereby amended to read as follows:

2.

Technical Soecifications The Technical Specifications contained in Appendix A, as revised through Amendment No.174, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

The license amendment is effective as of the date of issuance, to be implemented within 30 days.

1 FOR THE NUCLEAR REGULATORY COMMISSION N

George Kal an, Senior Project Manager Project Directorate IV-1 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: December 22, 1995 i

i 4

e f

f

l l

l ATTACHMENT TO LICENSE AMENDMENT NO. 174 FACILITY OPERATING LICENSE NO. NPF-6 DOCKET NO. 50-368 Revise the following pages of the Appendix "A" Technical Specifications with the attached page. The revised page is identified by Amendment number and contains vertical lines indicating the area of change. The corresponding overleaf page is also provided to maintain document completeness.

REMOVE PAGES INSERT PAGES 3/4 3-58 3/4 3-58 3/4 3-59 i

4 i

l l.

b TABLE 4.3-13 RADI0 ACTIVE L10010 EFFLUENT DOllTORING INSTRUMENTATION SURVEILLANCE _ REQUIREMENTS g

h CHANNEL g

CHANNEL SOURCE CHANNEL FUNCTIONAL INSTRUNENT CHECK CHECK CALIBRATION TEST e

E 1.

~ Gross Radioactivity Monitor (s) 4 (provides alarm and automatic isolation) w 6.

Liquid Radweste Effluents Line 0*

-Pa*

It Q

2.

Flow Monitor (s) a.

Liquid Radwaste Effluent Line D*

N/A R

N/A During releases via this pathway

    • A SOURCE CHECK is not required if the background activity is greater than the activity of-the check source.

i ta i

N S

l INSTRUMENTATION l

3/4.3.4 TURBINE OVERSPEED PROTECTION LIMITING CONDITION POR OPERATION 3.3.4.1 At least one turbine overspeed protection system shall be OPERABLE.

APPLICABILITY: MODES 1, 2 and 3.

ACTION:

a.

With one stop valve and/or one control valve inoperable, within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> either restore the inoperable valve (s) to OPERABLE status

)

or close the inoperable valve (s); otherwise, isolate the turbine from the steam supply within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

b.

With one combined stop and intercept valve inoperable, within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> either restore the inoperable valve to OPERABLE status or close the inoperable valves otherwise, isolate the turbine from the steam supply within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

c.

With the above required turbine overspeed protection system otherwise inoperable, within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> either restore the system to OPERABLE status or isolate the turbine from the steam supply.

3URVEILLANCE REQUIREMENTS 4.3.4.1.1 The provisions of Specification 4.0.4 are not applicable.

4.3.4.1.2 The above required turbine overspeed protection system shall be demonstrated OPERABLE:

l a.

At least once per 92 days by direct observation of the movement of each of the following valves through at least one complete cycle from the running positions i

1.

Four high pressure turbine stop valves.

1 2.

Four high pressure turbine control valves.

3.

Four low pressure turbine combined stop and intercept valves.

b.

At least once per 18 months by performance of a CHANNEL l

l CALIBRATION on the turbine overspeed protection systems.

)

At least once per 40 months by disassembling at least one of l

c.

each of the above valves and performing a visual and surface inspection of valve seats, disks and stems and verifying no 1

unacceptable flaws or corrosion.

l l

l l

l l

ARKANSAS - UNIT 2 3/4 3-58 Amendment No. 40,174 1