ML20095H928

From kanterella
Jump to navigation Jump to search
Forwards Reload Analysis Rept for Waterford 3 Cycle 6
ML20095H928
Person / Time
Site: Waterford 
Issue date: 04/24/1992
From: Burski R
ENTERGY OPERATIONS, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20095H930 List:
References
W3F191-0053, W3F191-53, NUDOCS 9204300362
Download: ML20095H928 (1)


Text

--..

Entergy OperatMns Inc.

==~ENTERGY

+

ty yy 6

.3 t..

R. F.13urski W3F192-0053 A4.K5 QA April 24, 1992 U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.C.

20555 3

Subject:

Waterford 3 SES Unit 3 Docket No. 50-382 License No. NPF-38 Cycle 6 Reload Analysis Report Gentlemen:

The purpose of this letter is to submit the Waterford 3 Reload Analysis Report (RAR) for Cycle 6,

which is included as the Attachment.

Three copies are being transmitted.

The RAR is being submitted because two previously analyzed events were not bounded by the Reference Cycle results, which are currently documented in the Waterford 3 FSAR.

This situation resulted in an unreviewed safety question;

although, these events remain within NRC acceptance criteria and no significant hazards are involved.

The two events that are not bounded by the. Reference Cycle analyses are the Large Break LOCA and the Excess Main Steam Flow With Loss of Offsite Power. The Cycle 6 analyses indicate that the consequences for the other previously evaluated events remain bounded by the Reference Cycle and also remain within NRC acceptance limits.

The Waterford 3 Cycle 6 reload requires no Technical Specification changes.

C3 sq Should you have any questions regarding this matter, please contact CD Roy Prados at (504) 739-6632.

CD 9

Very truly yours,

(

m R.F. Burski Director, Nuclear Safety-RFB/RWP/dc Attachment cc:

R.D. Martin, NRC Region IV, D.L. Wigginton, NRC-NRR, R.B.

McGehee, N.Ss Reynolds, NRC Resident Inspectors Office pol 9204300362 920424 DR ADOCK 0500 2

/

_ - _ _