ML20095C225
| ML20095C225 | |
| Person / Time | |
|---|---|
| Site: | Braidwood |
| Issue date: | 12/07/1995 |
| From: | Saccomando D COMMONWEALTH EDISON CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| NUDOCS 9512110421 | |
| Download: ML20095C225 (2) | |
Text
...
g Commonwealth litiwn Company
/
~#,
1400 0 pus Place d
I) owners Grove, IL 60515 December 7,1995 U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, DC 20555 Attn:
Document Control Desk i
Reference:
D. Saccomando letter to the Nuclear Regulatory Commission j
dated November 9,1995 l
Subject:
Additional Information Pertaining to November 4,1995 letter.
Braidwood Station Unit 1 i
NRC Docket Number 50-456 l
The referenced letter transmitted a summary of the steam generator inspection results for Braidwood Unit 1 AIR 05. Attached is Table 1, which was omitted 1
from our November 9,1995 letter. I sincerely hope this has not caused you any inconvenience.
If you have any questions, please contact this office.
Sincerely,
<~
Denise M. Sacco do Senior Nuclear Licensing Administrator Attachment cc:
D. Lynch, Senior Project Manager,-NRR R. Assa, Braidwood Project Manager-NRR C. Phillips, Senior Resident Inspector-Braidwood H. Miller, Regional Administrator-Rill Office of Nuclear Safety-IDNS kAnlaibraldwood\\119 add.wpf EBA22A8saasia!86 1i
_ Q.,,
PDR g
4 onia,m Company
Table 1
~
Braidwood Unit 1 I
A1R05 l
Tube Support Plate Integrity Program Tubes Tested With Intersections Tested SG Bobbin Coil Probe With Plus Point Probe A
95 24 B
75 45 l
C 75 57 D
75 254 i
i l
l