_.

i Comnutnwealth }Miwan Comp.iny g ';

-f II) ton Generating Station is O[

4150 North German Church Road i

}

11yron, !!.6101D9791 Tc[ 815 234 5 6 il November 21,1995

~PRIOTtITY P,00 TING

{ sed I Fi t LTR: BYRON-95-5157 FILE: 3.11.0530 S'h h.:-

1.%

N;LM vg+ /

.2fioS [n:t _ _..

ul M

n" -

Mr. Hubert i Miller EJi_

Regional Administrator DRMA 1.l.__.[._.___

U.S. Nuclear Regt.latory Commission (Region Ill) 801 Warrenville Road iN ~_@$'i_... _

1 Lisle, Illinois 60532-4351 i

SUBJECT:

Byron Station Unit 1 Application of Steam Generator F* Criteria Byron Unit 1 Mid-Cycle Outage (October-November 1995)

Dear Mr. Miller:

This letter is to inform the Commission of Steam Generator tubes that were left in service as a result of applying the F* repair criteria during the Byron Unit 1 Cycle 7 mid-cycle eddy current inspection. This information is being reported pursuant to Facility Operating License NPF-37, Appendix A, Technical Specification 3/4.4.5.5.e.

In accordance with Specification 3/4.4.5.5.e, the F* report shall include:

1) Identification of F* Tubes, and
2) Location and size of the degradation.

A total of two (2) tubes in all four steam generators had the F* repair criteria applied.

They are as follows:

Location From SG Row-Column Too of Tubesheet Size

  • C-11 - 54

-3.36 inches 2.01 volts C

35 - 71

-3.14 inches 2.32 volts The size of the degradation was reported from the rotating pancake coil operating at a frequency of 300 kHz.

g

' b-O /

9511300001 951121 PDR ADOCK 05000454

/

G P D_R _ _.,

p:\\sec\\byritr\\95-5157. doc f40V 2 41995 A limcom Company J

- ;h 4. <-

s; if'

Shduld ou have_ any questions regarding this matter, please contact Mr. J. R.1 Smith at.

'(815) 234-5441, extension 2604.

D. B. Wozniak U.

" Site Engineering Manager

. Byron Nuclear Power Station

' DBW/cb cc:

G. Dick, Byron Project Manager - NRR H. Peterson, Senior Resident inspector - By on Document Control Desk - NRR

= Office of Nuclear Facility Safety -IDNS

- K. Graesser.

K. Passmore

'J. Blomgren -

M. Lesniak --

'L' Zech Site Engineering File pi\\sec\\byrttr\\95-5157.do.:

a