Forwards Beaver Valley Power Station Flux Reduction Program for Unit 1 Reactor Pressure Vessel. Attached Flux Reduction Program Assumes Both Longitudinal & Transverse Data Acceptable for Use
ML20094L090
Person / Time
Site: Beaver Valley
Issue date: 03/16/1992
From: Sieber J
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20094L093 List:
References
NUDOCS 9203240308
Download: ML20094L090 (2)


Text

i De er Valley Power Statmn

$htpingport. PA 150U 0004 1412) 391 5255 JOHN D SIEBER Vice Prescent. Noctear Group March 16, 1992 U.

S.

Nuclear Regulatory Commission Attn:

Document Control Desk Washington, DC 20555

Subject:

Beaver Valley Power Station, Unit No. 1 Docket No. 50-334, License No. DPR-66 RT-PTS Flux Reduction Program T

This submittal is provided as required by la CFR 50.61 (b) (4 ) for

[

licensees who have projected that material in the reactor precsure vessel beltline region will exceed the PTS screening criterion before i

the expiration date of the Operating License.

As identified in our December 16,

1991, submittal, we projected that lower shell plate B6903-1 will exceed the screening criterion by 2 F.

The regulations require that we submit an analysis and schedule for implementation of a

neutron flux reduction program to avoid exceeding the PTS screening p'

criterion.

Attached is a description of the flux reduction program and 11aplementation schedule for the Unit 1 reactor pressure vessel.

In

addition, the NRC responded on February 6,

1992, to our request for approval of the methodology for margin determination as derived from Regulatory Guide 1 99, revision 2.

Approval was granted;

however, we were requested to verify the fluence value for lower shell plate B6903-1 and resubmit RT-PTS calculations incorporating the verified fluence value and limiting the data for chemistry factor determination to transverte direction only.

The NRC

noted, while reviewing our Decembsr submittal, that the lower shell plate fluence value differed from the value on record contained in the Westinghouse surveillanco capsule V
report, WCAP-9860.

We have determined that the capsule V fluence value was updated in subsequent surveillance capsule reports submitted to the NRC.

Capoule U (WCAP-10867. 1986) and capsule W (WCAP-12005, 1988) an updated capsule V

fluence value of 0.291 x co{gectly geported 10 n/cm based on spectrun averaged reaction cross sections derived from the results of capsule U.

Therefore, the fluence value for capsulo V as reported in our December submittal (WCAP-13106) has been verified as correct and shvuld be used in place of the value contained in WCAP-9860, dated January, 1981.

Our December 16 submittal also contained a specific determination of the chemistry factor used in the PTS calculation since we had credible surveillance capsule data.

The NRC indicated that Branch w

o 1A.

.n

(

h0f

~

i 9203240308 920316

,i PDR ADCCK 05000334

/'

I P

PDR

Bbaver Valley Power Station, Unit No. 1

. Docket No. 50-334, License No. DPR-66 RT-PTS-Flux Reduction Program Page 2 Technical. Position - MTEB-5.2 limits calculation of this factor to the use-of transverso direction data only. The Unit 1 RT-PTS calculations were performed in accordance with the current PTS rule (10CFR50.61).

Regulatory Guide 1.99, revision 2,-

was used in calculating the chemistry _

factor-based-upon surveillance-capsule data.

The guidelines specified that each adjusted RT-NDT should be used in the calculation-of the chemistry factor.

Therefore, in making this calculation, both transverse and longitudinal data were

used, consistent-with the appr(,ch used in the development of Regulatory Guide 1.99, revision 2.

A review of the technical basis for revision 2

shows that both longitudinal and transverse data were used in its developmont.

This.is not explicitly stated in the technical basis, but the tabulated data represents both orientations and was verified by comparison with surveillance capsule reports.

As a

result of this review, we-have not recalculated the'RT-PTS a

values limiting data to transverse' direction only.

The attached flux reduction program assumes that both longitudinal and transverse data are-acceptable for use.

If it is determined that Regulatory Guide 1.99 revision 2 is-not considered an acceptable method to follow, we

-would request further discussions of these calculations.

During the development of the flux reduction program for Unit 1, the required flux reduction factors-were calculated using the results of the PTS evaluation (WCAP-13106 submitted December 16, 1991).

Additionally, the average flux of Cycl'es 1 through-6 was updated to include Cycles 73 8,

and 9.

This updated flux was then used to calculate the fluence accumulated through Cycle 9 (8.6 EFPY).

This has-resulted in revised RT-PTS values for Unit 1.

The new values are tabulated in Table 3 of the attached WCAP-13208.- It should be noted

~

that the limiting material nrw exceeds the 270'F PTS screening criterion by l'F instead of-2'F.-

These.new values were used throughout the-development of-the flux reduction program as detailed in the attached report._

If ;you have any questions regarding this submittal, please contact Mr. Steve Sovick at (412) 393-5211.

Sincerely, j

J.

D.

Sieber Atta 7ments cc:

Mr.

L.

W.

Rossback, Sr. Resident Inspector Mr.

T.

T. Martin, NRC Region I-Administrator Nr. A. W.

DeAga3io, Project Manager Mr.

M.

L. Bowling (VEPCO)