Spec for Test Requirements for Dynamic Transient Testing of ASME Section Iii,Nuclear Class 1,2,3 & ANSI B31.1,Bechtel Piping,For Limerick Generating Station,Units 1 & 2
ML20094J464
Person / Time
Site: Limerick  
Issue date: 05/29/1984
From:
BECHTEL GROUP, INC.
To:
Shared Package
ML20094J383 List:
References
8031-P-364, NUDOCS 8408140326
Download: ML20094J464 (129)


Text

{{#Wiki_filter:-, 1 Specification 8031-P-364 SPECIFICATION FOR TEST. REQUIREMENTS FOR DYNAMIC TRANSIENT TESTING OF ASME SECTION III NUCLEAR CLASS 1,2,3 AND ANSI B31.1 BECHTEL PIPING FOR THE LIMERICK GENERATING STATION UNITS 1 & 2 ^ PHILADLEPHIA ELECTRIC COMPANY POTTSTOWN, PENNSYLVANIA Bechtel Power Corporatio'n San Francisco, California 1 / slWitti Additiow wo mbec I To Rev i WEhlhoy i 41684 R.e.vsse & ss noTel e sheet ( Q KhM/rYy f) G 16 % r *, *,,. M 4 e,~ Us, e 400 h&:B g NO. DATE REVISIONS APPROVAL 5-P-ll5(b)/10 B400140326 840000 PDR ADOCK 05000352 E PDR )

.-....-.-..-..._.......~--...a..... . w.. Cpecific0 tion 8031-P-364 pipe diameter of the position shown in Appendix C and the sensitive axis must be within 15* of the axis specified in Appendix B. Displacement trans-ducers and strain gages must be' located within one pipe diameter of the position shown in Appendix C. 5.2 The instrumentation system (Transducers, signal conditioning' equipment and recorders) shall be capable of-providing data within the ranges and accuracies specified below: Transducer Frequency Applitude Span *

  • Resiriual Type Range Range Error Error Acceleration
  • 2 - 150 hz

+30 ifs t t of reading 0.01g chage Pressure

  • 2 HMM18 z 400 psig An "

10 psig l l50 Ioad* 2-gz 0.1% of range Strain Gage

  • 2-2 hz 5000jastrain 20jAstrain 0.05 in.

Displacement 2-30 hz Dynamic response error only Span error for the piezoelectrics applies only for instrument temperatures below 400*F.

      • + 2 times expected value (see Appendix E) 5.3 The data shall be provided on magnetic tape and in chart form.

5.3.1 The tape recorder speed, gains and chart scales shall be such that there is no loss of data within the specified ranges and accuracies. 5.3.2 The acceleration test data shall be in a format suitable for single or double inte-gration and spectrum analysis. 5.3.3 The pressure test data shall be in a format suitable for spectrum analysis. 5.4 Instrumentation shall not be removed or disconnec-ted prior to final system Dynamic Transient Test Acceptance and/or reconciliation. I 5.5 It is anticipated that some parameters measured might not be within the acceptance limits. Should this situation occur, it shall be up to the Test Adtn. l P-ll5(b)/10 Rev. 1 l P'r t of m l lt

Specificcticn 8031-P-364 Appendix 'A' ~ DYNAMIC TRANSIENT TEST INSTRUNENTATION LOCATION AND DESCRIPTION LIST Nos. of System ID. System Location Instruments A Main Steam O/C (bp B Feedwater I/C 5 C Feedwater O/C 6 D HPCI Steam Supply I/C 5 h E HPCI Steam Supply O/C chtwgg R MSRV Discharge I/C" 10 S Feedwater Heater Drain O/C 14 M i Total Instruments Outside Containment (0/C) h*et 43 = Total Instruments Inside Containment (I/C) =j20 Total = M G3 14 of the instruments are also used for steady state vibration testing per 8031-P-363 Adtn, I P-115( b)/14 A-1 Rev. 1 Pyu# ly J

i .......--. +... -.., s.:a M. = w - --

- ~ a :: -- ~ ~ ~ - - --.

Specificctien 8031-P-364 Appendix *B TEST POINT INFORMATION System : A - MAIM STEAM Location : Sv6*p 'd c. C sest.;mJ n r7,d ts h- [ Isometric : SK-M. 15 0 2 ft s u. L Calculation No.: 1 220 MEASUREMENT QUANTITY HOD MEASURED DATA REMARKS 8 REMOTE VISUAL POINT INSTRUMENTATION 1 INSPECTION 2 l PRsssuRe op.-.A.o3 ppto A pgsss, tap b d* J-Pk ' n ' A

  • N 643 E

E50-l0'3-Hl(, M l (W m 72. A.15 W i a-io3-s ir. n LAJJ ? i 4 I i q Mtn,1 B-3 3 Rev. l

...,......,..,--~...~.-....e.vE%-w=~--...'..-u~-..--.-.-... .:.e_. Specification 8031-P-364 Appendix B TEST POINT INFORMATION System : A-MAln GTEAM Locatton : DetyM e. Corrta.Itwrrwen t-Isometric : SK-H-iso 3 Rev. N Calculation No. 31-or-224 MEASUREMENT QUANTITY HOD MEASURED DATA REMARKS E REMOTE VISUAL POINT 2 INSTRUMENTATIONI INSPECTION prs:5. TAP Pesssuna o p. . A. ol pPlor B PRssseRe O P. -. A. 0 2 pPlass Pr.iESS iAP LCAD DL. E. A.09 Bla a s.aB io4 -H IS LOAD DL.S.A.07 B23 susw$x,W) EeE-ic4 - Hlo LOAD DL.S.A.06 B23 5"8W( -Y) l LOAD DL. 2. A. 06 B3o 2 Delebed LOAD DL, x. A.05 g4o y pgjgged LOAD DL.X.A.02 B46 x pelgtod i LcAD DL.Y.A.of B 49 Y pelete.d 3 LEAD DL.s.A.o3 8 41 "sts4Y-z) 7 I r ese. Ic4-HL. LEAD Ot,S.A.04 B4l SkW6Y, +Z) / b' l-o o-d Dt.. Y. A. O BM y E3G - loy.H 2 e ( mee t.x

w. _.. A.oi

~ m v_.4 c.e 4 valV4 dosuft. p Tv av<l \\ Aa AJtii. I gl/ chl4 Rev.l B-4 L-

.a-h.._hl. nl.2L -. =u La...... :..... a a....-.. a...... ..,,...:....a..:.. \\ Specification 8031-P-364 Appendix B TEST POINT INFORMATION System : A-MAIN STEAM Location : Cyg9ld C, C enta.I D m or-:I h Isometric : SK-M-150 4 Ed V. N Calculation No.: 1 2.1 6 MEASUREMENT QUANTITY HOD MEASURED DATA REMARKS REMOTE VISUAL POINT 2 INSTRUMENTATIONI INSPECTION 4 LOAD DL. 2. A. to PSA E EBB-f o7 - (, LOAD DL.S.A.Il Chn"$ PSG msw(-vpy) 1, mas-1o7-I45 LOAD DL. S. A.17. j P56 SK&i-8,-Y) i i i $Un* l jk o#ILj Rev.l 5 B-5

. _.:.....-.- = -. :. s. a - - - Specific". tion 8031-P-364 Appendix 3 TEST POINT INFORMATION System : E. Hror hem +urely i Location a d ut*Id t C anto..' ri tw d r:Y l Isometric : SK-M-IF% B /P., e v. M 1 Calcu1'ation No.: F1-24 -5 ) MEASUREMENT QUANTITY MEASURED DATA REMARKS AXII REMOTE VISUAL POINT 2 INSTRUMENTATIONI INSPECTION l Los d PL. 5. iE. 0l 22 x noo-tog-H38 i L eo-d D4.t.E.0A /,3 g. g s s-/09-45 Load DL x.E.oS ?_2. x EBS-to8-H38 d' A 1 ~- Add j 0 1 1 i i i i i I l i i AJen.1 ~ s-1.2, P6-600 /4 "" I i i .-y._,%-w-

O 'e & I $ICokion uy f ( N 6 C > l - P ' % H -7\\% l l t b ff'Ct-rd I t ( g%{% d' F ',,i '. o,foi u h (',e' t' 'b' p rn ss

  • r

,f "A ..s - 99 etb% ? 4 84 y&gs. 4. ** E sO c' gag kh.g s ^ s'c \\ "4 t,a g;H -e f - 2,@ ,: ' M ~ h Yd,J)

  • "[

y, ec, Jdy Aho Anilutte on ..,.N;.e Aperture (ard '.esd .,^%,. 8 ^> f j/ \\ -li l.I$. N'.$ S ' :\\1. i

  • Il x*6'M,~>T ~t U iE I-

'7 S ? j,i 6 TI ' s. ' ' *o. g-D APERTUng CARD a#P ."%d c. ;,1,., .u.c...,_ B $i f Ji. s RIV OATE gy afV Daft gy oE LINT No. P M % gbl A Yva w yt.$~j3 !' !,I 840 814 0 3 2 6 -6l m a>= E

    1. ' M l

LINE THICKNE$s glgg " l,4 3 g o J g , Jp,Q, ;* 8 LINf 0 0.fINI d

  • 19 'lut 4

I M006 .i l. b -ll 59.ain esio j 5-,., m { oyu..._. p..,_, l cou e. "a uit-inn. l E,* uoo. o, s(g g ps,, k t'.(/, [ \\ l

STRESS ArrCovALS

.t V THEEMAL SF stui '

j \\ U W ~

  • I' 0 RFv L Norr-PP-I OI h, '

Pf.' (;TH,[l[!)15,25a'10Gn,W,7l.,7lll?t*,%'.': ~ s='V f,ill \\ / F [2D,t * / O ~' g :' d, g ' ) C !g rP .s.

  • r'f '

-, r t-

  • e is

$et n. e.... i / /, ,4 I ( ,,r'A,,g( . I'/,(, g.5 4 i = t P.*-ro3 l E o aet A*,3, s3 ]>/,,/4 r'p,%, 1 .g. es \\, \\.... s ~ ~ m .... o,.. I g LG-e= '% y:h6p 9 y'i 1(w Q.Q' P g % p,c. [,, B \\ ,$fN,,i, ~ ', % ifl.%. 'y \\. A g., [+ k .),, t*fef-atttatNet M,. , c [7, - /* d, ;, / M-Ol P & ID p 0 'r-M-3G8 PIPINCs PLAN '"h q m N, 'q.!, I f M EBD 103-l RFN.22 FAO ISO statss cue

  • s co sts N<.

ns s 5 eacs osscmpnov .,s, N;*' %s ..i ', q *.* (l', r%(s) 's '. 8* MCCE f*DfSMA! s /,,\\ N005 E htAAMWpf ) {.b J ~ ^ 4 ;\\ NOTEt L ^r O

f. G E. H tW G G P.5, SEE DW6 Nt g

80 3 5 - M "2 D - 1 ( t ) - t-SHT. 2 H / /h.. ~ % at

e..

a ,k% h *% v d' C'D.% o'* vs*, wir ct.m -i ) v s L Sir Rtv L isort grx *h / ' ' o. .r to*,Y X Y[vidia. TC R M.6T%5 F. 4 L . fl$ .n,. s. \\,L. +,4 , uw ;, =.s n.~ y / v = v vu u. rov-,s a So E Y *q 3,. yy D UMIT*2 EBB 2C2 is .E I? ) p 'y,0

  • '?

g J

  • V,, C04 t. sMt.*._M'D, tt)$ k

',T, f_', f ' s sury.stcso ni s"*1 ~499 x h. nter.Atto rire rn .* H 9. 9- ,-,*e 5 5, t,,... re u s. .- e a.es .. <. ?, ff g ,g l 9. i. i s i e o l dR..v.' " " " *. " ' ~ " ". ' * ' ' *

11. CC.-

. n.. =:- ~ I l OAtA REV OAtt SV REV OAtt SV L(GIND "d l "'"" l""* IE

r. t. pene,
e. sPnino HAncta BECHTEL IB necros ANcEn SAN FRANCISCO
  • ANcHoa LIMERICK GENERATING STATION f UNITS 1 & 2 to 8 %/,3 P
c. cui0s 8M PHIL ADELPHI A ELECT RIC COneP ANY t

a m % suvusa ISOMETidC TURBINE BLDG, utJiT *I H nestnAist j MAIN STEAM PIPlflG (tipe'f') o nA~cta uv.on. O 5tatss oatA Po'~r J l 8031 SK-M-IS02 L' e Of e 9

1 !:seecOc.~eton 't ' 4_..; y h'O'S l~ P-Ao 1 N \\ pp.uoug L VM. \\ j g /DL.S. A.0y7 /Cf G A c4a i nyrend;y.c. / ef" - i 0.) vg n l l* ' 4. $l ' ;., '**Qg i ~ , W: 2, j i l , ?. :, Pk. Cf..N."A.09 .,.y. %Q.fN'yf l 7....p' - Q, g.N. :

9,1 9

os.x.n .,yD.g. Dh. i \\, en d.4... icT;39 y jr NOTri PlPC vsALL THtCJtNE.SS.. *. .U AI BUILT-UP To MatcrG.E. yAtyg,,0. n, %gf .; AT INTtp,M. ' ...,,.,f. ese ,j ,e

      • f
09. T.~oi;3, '

... '4,. i . ~. - - - - r e-,p n ;. : c c. s. ~ ~ ,fs '.*j [: Abo Available Un N,, j_J Gb.c Aperistre Card /, + I' :. .r t88.CR(d .'I 't ;. .WP.Ett74'-SV { i 4 .1 d, - \\- TI i_, .j. p.,).1;.,. 21.c.. ~ N,i APERTURE L CARD [.c ur. .v on ..v n 5 ] z'? gg une n 'E88 -lo4 % A%%s obl A Wir. a [j ua, taint 4~'n'!M'.t-i; .E .k UNE THlCitNES$ 0M,$3 T .431., = p u mo.nm ze u.2s t A v>w **4 4 u g9o[/If y 'i uoos - r a as ' i g I ...n ,v.; O n 4 u, o.. C - 12, . = u,. - r1 = a " _,,,n,.. ,t Rev,l [ 4==. on, tau,,, l l 840.8.140326.-01,,..' t i

I-STEE$$ APPROVALS (' J -) 5 ', 'EV THEEMAL $Ef5MIC f f A 'J r $24 l /

p. M-4 4-f

/ Rev N Norr: { h. JCLsD PtFE su 90 tis t DATA 9moen,T3 eon. st.El'ONCIL,ATMJ/ l / Q** ' ' f, * [ : CELETfD ieskv4,mtsst g 7Kpf.104!J PER STJt11'3 CRatJ e yr 8 H A EK *stP g. v.!. \\ mcr ra.e .._p... p.e 5..s, m srms i-s A,.mu o.iu.ty p. e. [ 9.s. 7, fi.c b,di., as rouov. .g sp..a. ,n u ~. i - ~. i

  1. ) q f.e.

l As snown o.a..uno n -f q Q,7 4,j/ E(j'.. Ad zschc.",": - ris.no ^ ./ N 4 '+. %aLw usvg. s en o=>om or ll./,V v Mao.i.usm a r o C '3 b. p , g,,gj. 6 f y.- e.y 'a,, 7 3,, ,e.. e,, 3-P ! 1',9 'I'}.f' ADDT.D. NOTE..A5 G44/B504fEL INftUAcE 87Ev.X NOTE *. ~' G . # 4, - k ~ m h 4 yIT: FCR M-4419 F)h..af, F g W~o

Rd*

'.\\" ~..t s' ',, s'

\\ - f=

~ 5 a 5;,.y;; ',

  1. )

taf 0 f.Bq% % 3'Y',gkV',D,.'*c.}g 4* ~ s REFERENCE p,. j 3.. q, }. = , r. rJ: M -41. M ";q P { l O . /,. y ~ ^ : f-p 4,fx M.;. r /'.. r.1 01 l ' V T.P l 10. M-%8 " PIPING. PLAN ^.' to Q kir *I'I p [,[Ift a T 4'

t., x '-, -G.3 r "o

.' EBq404 2 REV.q,.: FAS.30.;- EBB.lO41 REY.25, JAB..I'50 ~. w

u,A..g.

44,.,(.2 c4te. e-oe-224 MODE _ D%CRIDflON e* \\ s*,'y M., MODE T. - DESIGN ...y s ~. . We .. _.. ' ~ ,'M'8'0' ' ~ qh.. . M.oo.rIr-m. x: mum t )

  • 3,..

.,.g. o ~* a NOTEI. q , et

8. G E HauGEit $, (S EE Owa. 54 e
  1. ti 4

\\' ]A %,,c,# .Q~,f.5'. OL.s.A.oh\\ 8051 - m,2D -1 s) - 4. SHT. L.. ./.%. 9 .,t.* t ~.O ^ - 1,.*.- c. ~,,@% g m.%. '.. O Li l ,..p r... e,.. .s*..eer ....R + 1G' s.; f..... - ... u s. ,,3 gj 3x :, t,',", ,,, h. [ hv .O. r . J. , {,' ' '4; h,'%.~ t' g. L *,2".@..,w ou,. row dh' - e sc.rce. u mu...... t ... ~. - gy,.%.... F. .7,. ~. c na rwe. c.. - w. 2... w )..*.c e-t i g. g [. h;.~-. ,s ,g*wqp-h c; f'.y..' ; .t . *Lt. . f,, g * )E*'. .L '

.-..
    • Q.:.. -. ' ' * -

y f p,,. p. ..,:.,..... c , r, p*" >s sys a 4 U b* E N# D k-I,. $k ( t a$,W..e.d,.f....,., - - -,r _ ' - r; - s.t 6 i e f-w +g q mm,a..., Pf 17-1,,-, srv F0f* UNIT-t Sts. . ;^, .%.. qc ^..

  • i;* -

Mces.usW m w , 1 ,th eqen. sow war a awin.-* E* FT' 5"L A* t. - Q 'g' AJ.4..."/.(,s...T..N ',* icf [, * ' if' PP PP l g,I.t 5 Y E D l

  1. A D','Irb%sa N4 SMll A'M85

,l s y;.=.* e ,,m 'h s h"***w l an.es lC . DATA sa'# REV DATE , my ' Rtv i DATE SY LEG (ND "**8 s,Rie.owancia BECHTEL."

c. t. Firmar;"'

N-pHMMmW e-Ric Dwanc:R t A ascuoR LIMERICK OENERATING STATION UNITS 1 ai 2 ,, j,.. & %4 4%a .s. cuice 18 rwitAostrue A etseTRic comeany % snuse R n -me 1-4

  • tsoMETRic TURag..E BLOG. UNnTTI:y

( U N IT. ./.j 2.~... "* -.:- H Rasmint ., e s-A... O HA=ceR wu=un.) ,,M Al N STEAM' Pt PI NG -('ug*b'). .n. < r.i /. .S., ~ . 1 t-t -l Q STRES3 0 ATA POINT 8** .-==a-sost SK-M-ts03JM l..I.. l.,.., s 1 1 \\ l. y 1 , :r) J

T W F j 1 hf u_ t. s v'Ct 4.,. f 8 w,7 6C31-F-3 L 'l / 6 N i g /- 'r y. ) f..) C \\ c.. # ' r i g [!rW hdt% { l C, j.Y. d 88 -.s l I i

t.,

f % }/c s f.D# .f 4,) h-9 C N l

  1. t.

1 -.i j.

  • y,s.Q-e o

e p". \\' t)'o. \\

  • T',

i Ada s i f js i

  1. [*'p'*9 ch dy j'

e \\ V ' t* *#- 4 C

  • a y iy 1

ff Ng /NV\\ , ('., 7,,< ;v t-t \\V 'g.J l 3 It g! \\. .l; 6.d ' - $g4 - ' 6- . s t4 s 0 ** 1Q 5 b AH . c,- -\\ t!.i.u..),L l /, *. : 3 g*L .p t ..t.. ,.s. 1 .f * , h*f ,1. ' /, .' A fpf, { L.# 'J' - it.f,..,.* %

1.,..e 4,.. p s

.i s e, .4 <., e.. - %+c s yp d.y.:':,e. r QI.:g,'N 7, ipy@'p d \\o, W fl'.g, i,'g'f y - y.... r, {f. ,. e;;. e Y*(f'qzu;lR.,y' / ,/ gw 'kniiNe 0" s' n,:,1

  • . +,e.j 3vcriore cara s (,,..

s .t.. -4..p@,9s.L*'@>w S-e .e-y .,f

. ~

,, a,,. ) Ij 9I, f' '=9L, ' i '/' 'I l4

  • P-6

. 4. N \\ pu,- fp,, f:;yl .y ..'t . q.,~ Dt..ii, E O A ' ( f.h %' 9 m , o.. )'..e4, / b l, 'j .f # 4" '. e / / l Calm OATA alv OATE ev '=EV IDATE l stat M n'.es a.. l gg e y9 ,,j g vattni4L ..#., a w r, p.,,,g e,, ta. E 2e M T. 08r renc,8tss nm ;.c.-'i , e..: C 717 D // 7 f f. /h O[n jy Lit.t o o ONi ,; 9,o ,9733 g j.g g g e00f y g g gg gy rat's P*.ac hm l% 3 fiv** ,j t xP COFFF. IN settT q h d{,t,, l .:; t.e. cou s 4-wit. 8,,.4 .cV I % vftLA: e e :e 84'08140326-D3

[ i

ra. sccmoveu

[ s I h m rataval I s e,svic g f l/ / .55 p'- ~1

  • 7-s*,1,,s.'*

a h t,t w T e - t r 9 37

g. i,.

TM14 CYJ 'a .N 87 suG T.: 9 1 ' E S jam.3G2 , ft.s1) pv ' #-ly,r 4 V I. f!:.'.c t -) ;; .i I,.,; ,ACCED NORTH ARRof.' cotor r ut.m..ou, m,w m,o, p n~y N.$",'Y...v,.. s r/ l M I: % O ^~' " k% -9 1 Jh d gn m d.s.. c

  1. ( I, :*'

'~ s

A c:o any w,..:.:. y :.:n anves

\\ k' l , ??h' HANiot C A4st 4 A .J.!' .s. m u.s,.ss:,o w e.w ia s ~ ~f< .s p N, i j j a ~ '

  • h,,

~ .',(. - s' 2 / c,sococo PoM*od 08 '50 f* s" u, e op v 17. o ast.80% l 4,s, p,p '7 atta.t e m u so.asSCC l I 'II NCE f 3 el 10 () 6 4.

  • f *J 'N A.

I 4'5 "

v. G3 pggp I

/:ffA-j'

V * "??

,P#wM9 PV.J ,I

r g

/s s, n.9..d, 1 j .fF' .W* g 2D 3.,. (.,., ,.: 6 m wo i eri e F*w. i e o. s .d I h F 6 6 tvJa. t E E'/ ;.* . '. 41,. $[D gi. J ucos ochcwrwn -~ c .c s e,!,,, uoCT,1 - p.t* M*4 S f 4 Tc M Nort of*5srAlme / .- l c.mc mon, ,,,) /~ M oDs !1

  • M M iu sti EMic.Pl ce'mTidH9 t

MJD5 3

  • W'Ut *st SYLT C M.:'t 1* R Nri,4Cr *

, 60 ttp,i co icririo,,c,. s. v,, t /.,,,_._P19 03*) l snew cate. p,.24_3,. D'f2 fs'ldt'.;,i e 1 , V. /Ot.. T. u.or'\\ I. ?. y?'- n ,*e. r I.n. re.js s n.Y N Pk7E'q. ' N _6tf 8'.v'a"V. s / m e,,a n. co. re: .- a r g .s.. s s. "* 8,/ h lt'ltCCfPT..!!?*E

W [$ t.*/ / l ' a.'

MN P, l& " ff.MC#5 FV IM l* l',, - ,. ' da R E V.,, lay w rte.n.4hw aca g.$-...- /;,.i n

r. cam ><w

/.i r - F, CALC. a ':-orsr",our et v s. +f F i M.u..W E 7-4*P sTr NO Pi 2 Mi 1y.. u.< :.- a w

.au

.o., ...a* n. ~ e .i La._y ryg 'c;.,%.~ ' a uc-1. V'.:w: e

i..
.v..

!i C4fa j atv l nart av may carg ny (gognn i n.. l... jo...Lu..v. ;;*; !I o sm.o...e.ce i. 5ECHTEL E nacio u n,,c,,, SAN FRANCISCO e ll l l h antwon LIMERICK GENERATING STATION UNITS 1 & 2 l 4 cuior PHit AOf LPnetA tLtCrm'C COWPA8eV l I E E % tNUSPtm I g o n,,, a,.,, isouswic Puerer e,uwins k % f7tS9t.f"c Cx Utii it:J E C Tl/W g umit L t O 8031 SY'WIFM B FJ '(0/c) HPCl STM' * .~ ,A

.;y , y ..,.....:...n. - a';- ~ w_ - _ ~- - ,!s .a \\ Specification 8031-P'-364

  • a Appendix B TEST POINT INFORMATION Ckuge )

System : R "**v DISCHARGE ^} OFdo.\\Mir"'dMD~ Location Isometric : SK-M-1794 N4U' b/ ' Calculation No.: i oi MEASUREMENT QUANTITY METHOD MEASURED DATA REMARKS 8 REMOTE -VISUAL POINT 2 INSTRUMENTATION 1 INSPECTION 33'o S KrWC+'.'Y.-L GBc - 1o1-H16 C, LOAD DL. 5. R, of LOAD DL. S. R.o2 335 saw(-xl-z) GBC-1oi H4 69 LOAD DL.2. R.03 355 2 GBc-ict - H162 LOAD DL.Y.R.04 3 57 Y GBc 1of-H io6 365 y asc-ioi-H ar2 LOAD DL. Y. R. 05 LCAD DL.S.R.06 372 scsw(+x,, ) Gsc - <o t - Hi 79 LOAD DL.2.R.07 37A E GBC - foi -H l76 LOAD DL.S.R.08 380 558WC-x,-2) qsc-foi-H 87 LGAD DL. S. R.09 381 5rsW(x,-a) GBC-iof HSE LOAD DL. Y. R.10 39o y' age _{o1 Hl74 DS [d d 312 DtSPLACEMsNT DD.. R.ol 4 ' CW/ e,6 ed PRESSURE DP.- R Of 340 t. 1 Q E' =

Specificction 8031-P-364 j Appendix E i l STARIUP TRANSIENT TEST INSIRIMNIS FOR l MAIN STEAM LINE B AND BYPASS TO VALVES l Iocation Instrument 1 or SK-M-Axis Design Acceptance l Ntaber Data Point No. Dir. Maximun Response Carrunent DL.Y.A.01 B49 1503 Y Deleted DL.X.A.02 B46 1503 X Deleted DL.S.A.03 B41 1503 SKEN(1) 1 9300 lb. +50'V skew DL.S.A.04 B41 1503 SKEW (2) 111100 lb'. +40'V skew DL.X.A.05 B40 1503 X Deleted DL.Z.A.06 B30 1503 2 Deleted DL.S. A.07 B23 1503 SKEW (1) 1 5500 lb. +28.82*V skew DL.S.A.08 B23 1503 SKEW (2) 1 5500 lb. -28.82'V skew DL.Z.A.09 B18 1503 2 +60000 lb. DL.Z.A.10 P3A 1504 Z 126300 lb. DL.S.A.ll PS6 1504 SKEN(1) 1 6000 lb. +25.54*V skew DL.S.A.12 P56 1504 SKEW (2) 1 6000 lb. -25.54'V skew DL.Y.A.13 B33 1503 Y A4d -+ 2300 lb. DL.X. A.:.4 - _ ca 1502 (DL X A. 5 i _ 543 _ 1502. -~_ - _ + 110000 lb. TotM DP..A.01 PP101B 1503 NONE ~ ~ 2 1 a n -- w dele 4:-e. DP..A.02 PP138B 1503 NONE 14 0 p- * ^ ~ DP..A.03 PP101A 1502 NONE i ' ' O ;- ?-- DP..A.04 PP101C 1500 NONE i n p-R DP..A.05 PP101D 1501 NONE -1 1'^ g f* DD..A.01 MSV-4 1503 AXIAL Deleted g Notes: 1. See ndix 'B'

2. Qync-m I c. fr e4 s u t L. 'brc~r 41 er,t n o-t; ' hot N 4+t J

ha r,c <. M eo.s vr.1n de ulo e, c.cc

-,,.,--,_-,..,,,,m,wwne.--,,,, n e n,


gvw----

s,-----n.-- - -,, -, - - >

Spscification 8031-P-364 pipe diameter of the position shown in Appendix C and the sensitive axis must be within 15* of the axis specified in Appendix B. Displacement trans-ducers and strain gages must be located within one pipe diameter of the position shown in Appendix C. 5.2 The instrumentation system (Transducers, signal conditioning equipment and recorders) shall be capable of providing data within the ranges and accuracies specified below: Transducer Frequency Applitude Span *

  • Residual Type Range Range Error Error Acceleration
  • 2 - 150 hz i30(fs 5% of reading 0.0lg Pressure
  • 2 -1000 hz 400 psig 10 psig

/N 0.1% of range T. cad

  • 2 - 500 hz Strain Gage
  • 2 - 200 hz' 5000pstrain 20jastrain Displacement 2-30 hz 0.05 in.

Dynamic response error only ' Span error for the piezoelectrics applies only for instrument temperatures below 400*F.

      • 1 2 times expected value (see Appendix E) 5.3 The data shall be provided on magnetic tape and in-chart form.

5.3.1 The tape recorder speed, gains and chart scales shall be such that there is no loss of data within the specified ranges and accuracies. 5.3.2 The acceleration test data shall be in a format suitable for single or double inte-gration and spectrum analysis. 5.3.3 The pressure test data shall be in a format suitable for spectrum analysis. 5.4 Instrumentation shall not be removed or disconnec-ted prior to final system Dynamic Transient Test Acceptance and/or reconciliation. 5.5 It is. anticipated that some paramet.ers measured might not be within the acceptance limits. Should this situation occur, it shall be up to the Test P-115( b) /10 Rev. 1 i l

Spccification 8031-P-364 Director, after consultation with the cognizant Test Engineer whether or not to continue the testing or proceed to further testing until the test parameters levels are reconciled. Project Engineering shall be informed immediately of any test results that exceed the acceptance criteria. /b 5.6 All original charts and tapes shall be properly identified, dated and signed by the Test Director and stored in accordance with Plant Administrative Procedures. 5.7 A copy of each chart shall be provided to Project l Engineering for information and action as necessary. 5.8 The instrument installation shall not affect the thg operation or integrity of the piping within the test scope or adjacent piping and equipment. 5.9 Prior to testing, a system walkdown shall be conduc-ted to verify that the instrument installation is in conformance with this specification.

6.0 REFERENCES

6.1 ASME Boiler and Pressure Vessel Code, Division 1, Section III, 1971 issue with all addenda issued through winter 1972. 6.2 ANSI Power Piping, Code B31.1, 1973. 6.3 Piping Class Sheets, Summary Sheets and Standards 8031-P-300. 6.4 Technical Specification for Installation, Inspec-tion and Documentation of Pipe Supports, Hangers and Restraints, 8031-P-319. 6.5 Final Safety Analysis Report Chapter 3, Section 3.9 and Chapter 14. 6.6 Stress Isometrics (Included in Appendix C). 6.7 Piping and Instrument Diagrams (Included in Appendix D). P-ll 5( b ) /10 Rev.1 i i

l Sp;cificztion 8031-P-364 I l APPENDIX A Instrumentation { i I l ) i l P-115(b)/10

Sp0cification 8031-P-364 Appendix 'A' DYNAMIC TRANSIENT TEST INSTRUMENTATION LOCATION AND DESCRIPTION LIST Nos. of System ID. System Location Instruments A Main Steam O/C 15 B Feedwater I/C 5 C Feedwater O/C 6 D HPCI Steam Supply I/C 5 E HPCI Steam Supply O/C 5 [bs. R MSRV Discharge I/C 10 S Feedwater Heater Drain O/C 14 Total Instruments Outside Containment (O/C) = 40 Total Instruments Inside Containment (I/C) = 20 Total =W 14 of the instruments are also used for steady state vibration testing per 8031-P-363 i P-ll5(b)/14 A-1 Rev. 1

Spacifiestion 8031-P-364 APPENDIX B Test Point Information l l l l P-ll5(b)/10

Specification 8031-P 364 Appendix B TEST POINT INFORMATION System : A - MAIM STEAM Location : dut9,'d e. C ot-s kinter tid Isometric : SK-M-1500 Rev.M Calculation No.: l 2.2 6 MEASUREMENT QUANTITY MEASURED THOD DATA REMARKS REMOTE VISUAL POINT INSTRUMENTATION 1 INSPECTION 2 PRESSURE DP. A.O4 P PlolC, PRESS. TAP l f B-1 Rev. l r

SpIcification 8031-P-064 Appendix B TEST POINT INFORMATION 1 i l System : A MAm STEAM Location : dut9e'd e, C #tdx::Jt'rnet' D Isometric : SK-ft-15o1 R. e v, L Calculation No. : l-of-22/4 i MEASUREMENT QUANTITY THOD MEASURED DATA REMARKS REMOTE VISUAL POINT 2 INSTRUMENTATION 1 INSPECTION PRESSURE DP. .A.05 ppioi0 PRESS. TAP 9 2 4 f l 4 1 l l B-2 Rev.l ~,., -,, -, - -. - - - - - - -,., - - - -,., -., - - -, -. -. -. - . -,, _,, - - -,., - ~.,, -.. - -

Spscification 8031-P-364 Appendix B 1 TEST POINT INFORMATION System : A - mat 4 STEAM Location : 64*p 'd g. C sMMr7f77 d t5 b Isometric : SK-M. 15 0 2 IE e v. L calculation No. : 1-ol-220 MEASUREMENT QUANTITY THOD MEASURED DATA REMARKS REMOTE VISUAL POINT 2 INSTRUMENTATION 1 INSPECTION PRGssuRs op._.A,os PPtofA PRsM. TAP low L DL 5. h, lH Sy3 'A g g g _ go3-y ll, f B-3 Rev.l ~ a- ~. ,,,,, ~.,, - - -. -,

.u_.. Sp cification 8031-P-364 Appendix B TEST POINT INFORMATION System : A-Main STEAM Location : Ovtat,Me. C.,octrtsa It-stv ret, t Isometric : SK-M-1S03 R.s v. N Calculation No.: l-o f-2 2 /. MEASUREMENT QUANTITY HOD MEASURED DATA REMARKS REMOTE INSTRUMENTATION 1. VISUAL POINT 2 INSPECTION PRESS. T AP PRES $URE D P. . A. of PPlol B PRESSURE DP. -. A. 0 2 ppt 388 PRESS. TAP LOAD DL. 2. A.o9 BI6 2 Ess-to4 -H l5 LOAD DL.S.A.07 B23 sks4xp) gig LOAD DL.5.A.06 B23 9848,-Y) LOAD DL. 2. A. 06 B3o 2 Delebed LOAD DL. x. A.05 B40 X Del 6ted LOAD DL.X.A.o2 B46 x pg,j ghod LcAD DL.Y.A.of B49 Y pe lete.d LOAD DL.s.A.o3 8 41.staw(q-Z) i ese - 1o4-Hiz LOAD DL,S.A.04 B 4f

skaa@z +z) 1 oo-d Dt.. % A. I'5 B 33 7

EBB -loH-H A A l B-4 Rev.l

m,;............-.:._,.. Specification 8031-P-364 Appendix B TEST POINT INFORMATION System : A-MAIN STEAM Location : Cyys,ld & C ent4I n 177 et,T-Isometric : SK-M-15o 4 /24 v. H Calculation No.: I 2.7 0 l 1 MEASUREMENT QUANTITY THOD MEASURED DATA REMARKS E REMOTE VISUAL POINT INSTRUMENTATION 1 INSPECTION 2 LOAD DL. 2~. A. lo PSA E EBB-lo7 - EG LOAD DL.S.A.ll P56 saw(-vay) nas-10~1 HS LOAD DL.S.A.l7. P56 SKEW (-5-Y) B-5 Rev. l

. ___ s.. Specification 8031-P-364 Appendix B TEST POINT INFORMATION System : B - FEEDWATER Location : Ir, + e'd c C op.,4:;oJ r, er, e n t-Isometric : SK-M-155 2 Rev. 'J Calculation No.: 1 O i MEASUREMENT QUANTITY METHOD MEASURED DATA REMARKS REMOTE VISUAL POINT 2 INSTRUMENTATION 1 INSPECTION ACCELERATioni VA.)C.B.g 145 B X h 5 4. A. 5. 01 4:cstaneow VA X. B. 05 145 X DL A-101-H 2. A<. VA.X. B.o A AccusRATION VA. X. B. OR gg g w,,,, yA, x, g, o3 ACCELERATION VA.Y.B.O3 )O 7 y Wo-6 V A.Y.13. 09 60G h 6 M.E.B.06 VA. AccELERATiog I l l I I I Acceler~om eters c ee. culso veed 4-or stedy s ke.k s Vi br~c-,t-lon t e s tiny p s r-4 0 3 )- P ' % '5 B-6 Rev. l

s.. Specifiestion 8031-P 364 Appendix B TEST POINT INFORMATION System : C - FEEDWATER Location : duhtre'd C Casta.Jr'm ent' Isometric : SK-M-f564 Ret /, M Calculation No.: Pl-15 -61 MEASUREMENT QUANTITY THOD MEASURED DATA REMARKS i REMOTE VISUAL POINT 2 INSTRUMENTATION 1 INSPECTION Acc.ELERATIM VA. Z.. C. 0 3 39 gg v4ugg opspAyog (M o-l09A) j Acc.e le.re m eter s cu n e. o I s o us ed b o r S hec ~ d y ertek* vibres.' o r, t e,4 M r y y e r 8 0 5I-p - 3 4,3, B-7 Rev.I

I Sp.cification 8031-P 364 Appendix B' TEST POINT INFORMATION System : C - FEEDWATER Location : dutte'd e Cor1rta.irsm er D h Isometric : SK-M-155 5 IEe v. F Calculation No.: P/-15ff MEASUREMENT QUANTITY THOD MEASURED DATA REMARKS REMOTE VISUAL POINT 2 INSTRUMENTATION 1 INSPECTION AccE.LERAT104 VA.X.C.Oi t3 VALVE OPERATOR (Mo-lF032 B) A:CELERATioN VA.-E.C O2 ISE 2 4 l 1 Acc sIseom etets wv.a. w Ise v s <. 4 E-or sbsc Ly sbote. vi brutIor, testie,y per 903 L - P-% 3. B-S Rev. l

Sp;cification 8031-P-364 Appendix B TEST POINT INFORMATION System : C - FEEDWATER Location : OUTstre couTAiwME9T Isometric : SK-M NoNG. 64 e ve r' d.ar print 60 31-th 11 /3 Oc l Calculation No.: No9s 1 MEASUREMENT QUANTITY ETHOD MEASURED DATA REMARKS REMOTE VISUAL POINT INSTRUMENTATION 1 INSPECTION 2 PRE 550Rs D P. -. C. 0 I PPilBA pgs, song Taps es .EcutPMENT No22.2, PRESSURE D P. -

  • C
  • O 2 FPit8 B (FEEDWATER HEATrrA PPitsc.

/ p,, y_ ) PRESSURE D P. -. C 03 l l l B-9 Rev. O e+ _.mm. m_.

Sptcification 8031-P-364 Appendix B TEST POINT INFORMATION System : o-HPCI 9tseo.,m 6vpgly Location : Zn 9fd g. [.g ybe_{mpngpW Isometric : SK-?t t 592. f2e v. L Calculation No.: 4 - of - o3 MEASUREMENT QUANTITY METHOD MEASURED DATA REMARKS I8 REMOTE VISUAL POINT 2 INSTRUtiENTATION1' INSPECTION LOAD 'DL 6 D O[ 217 SEsw(-rfz) tBA-to6-HG LOAD DL.Y. D4 0 2 316 Y DB A-to6 Bt0 Acts.LERATION VA. X,D.Of 2co E X ELBOW END X ACCELERATION VA.x. D.02 WELERATm4 VA. Y D. 03 4oo Y VALVE OPERATOR I s s 'I s Acc.s i eteme. b e ts w ne wl s o a s e.d Sor s kendy $%be e v i b'tcuti o, b e 6 t-l t y P er 6031-P-3 63. i j B-to Rev.l l t w y )f

Specification 8031-p-364 Appendix B TEST POINT INFORMATION System : E - HPCI $ b e rr7 f l yyy Location : duth.'d e. C onte.;ntn ent;- Isometric : SK-M-1556A T2 w. P b Calculation No.: P j 72 MEASUREMENT QUANTITY METHOD MEASURED DATA REMARKS i 8 REMOTE VISUAL POINT 2 INSTRUMENTATION 1 INSPECTION AccELERArioN VA. X. E. 02 47 X Wa 6 VA.X. E. o I ucatu4 Tron VA. X. E.03 ACCELERATioH VA

  • X. E. O /

I6 X VALVE OPERATOR Ws s VA.1. E.03 l heceluom e t ers a er wiso vysd Soy ~ ss e c d y s k + e-vi br% b s'On te.s b Ny y e.v' 90'3 D - P-%3 B-Il Rev. l

t specificatien 8031-P-364 Appendix B TEST POINT INFORMATION .3 ~ system E-)+rcz ssea.rrs suryly Location d utvId 4 6 des ho.i ri ers S M-f-Isometric : SK-M-169G S'ildev. M Calcul'ation No'.: Fl-2y-5 J s MEASURENDTI QUANTITY MEASURED HOD DATA REMARKS REMOTE VISUAL POINT INSTRUMENTATIONI INSPECTION 2 Leo d 17L. )L. E. 01 22 x go o-IO G - H38 L. 00-d ' D t. 2. E. 0 1 (, 5 y ga a-to 9-H 5 I i t 4 /% h, - s A ' f,i l ~ l.o B 13 Rev. l [,, % 3 j! L..___._ s. + e a -- -w w = - - - - ~ - w-+-,-rmb -ow wr =-*-r-+,-- -m- =-n-=-=6w www-en----,www,--=~w-~ vrw,* --w-=,*-=- ww

1 2.. Specification 8031-P-364 Appendix B ' TEST POINT INFORMATION System : R - MSRV DISCHARGE Location : $UC9?d e C0Ftto In tr'enD Isometric : SK-M-1794 188 U

  • b/

-Calculation No. : 1 oi MEASUREMENT QUANTITY METHOD MEASURED DATA REMARKS 3 REMOTE VISUAL POINT 2 INSTRUMENTATION 1 INSPECTION LOAD DL. S. R.Of 330 SW(M*Y.-L GBC'- 101-Hin LOAD DL.5.R.o2 335 sug-x;-z) qsc 1oi H459 LOAD DL.2. R.03 355 2 G8c-iot - H162 LOAD DL.Y.R.04 3 57 Y sec 1ot-Hio6 365 Y GBC-ioi-H 'f 2 LOAD DL. Y. R.os LcAD DL. S. R. 06 372 sr.w(+xpa; G sc - to 1 - H179 LOAD DL. 2. R. 07 373 z Gsc - foi -Hl7e LaAD DL.5.R.08 380 snew(-%-2) 4BC-foi-H 87 LIMD DL. S. R.09 3BJ SW(6-2) GBC-fof HSB I LOAD DL.Y. R.f o 39a y age _4og _ H174 Do /dM 3i2 DrSPLMsMewr Do.. R.ol PRES $URE DP,- R Cl 34o Deleted i B-13 Rev. / r

Sp;cification 8031-P-364 Appendix D TEST POINT INFORMATION Syatem : S - Fe e.dw&ter Nester-PiwIn Location : 64 6 Id d. d,ats t e,) n n, e n Y Isometric : SK-M-33% IE4 v. H Calculation No.: L l-l !-2.0 A MEASUREMENT QUANTITY OD MEASURED DATA REMARKS REMOTE VISUAL POINT ' INSTRUMENTATION 1 INSPECTION 2 D3riuenent PD.%. 6, 01 258 -X O D.X. S. o;;t. 90E x 17e,leted g O D. Y. 6.0 3 '?50 D D.E 6.0 4 75 E E Stesss DS. .S.01 TSI D S. . S.02 TS/ ~ D6. .5.03 Tsl DS. .5.04 7 61 DS.~.S.05 TSR ~ DS. . S.0b TSR ~ D6. .S.07 TS2 DS..5.06 1 TSR DS.~. S. 04 TS1 a 9tsrharwrk V O Y. G 0 5 90E. y )(\\ sere + 3 ps.. 6.10 T61 d B-I4 Rev. l ,,,._.----...,.,-..,--,,...n..,,-ce ,,.-,,,,,,.,,-,..~..--,,--.a,, ,,mn.

l Specificcticn 8031-P,364 Appendix B i: TEST POINT INFORMATION system : S-Feedwmter H ee ter Dre in Location : Outside G on hin ment Isometric : SK-M 3 3 A /Cdv, # Ic et 6 cotior7 I (I6/) calculation No.: l - l 4 "A C A ^ A -X d'X - a t. north) = + '/ <--- A-67,S8 S,, $ g ( \\ 90* \\g a [] SM 64) 58l 53 u 5 H53)U S a, 5Y S 5, S G S 5, S 6 A-g,c,g;,n g_4 i Top Vie w Si 5A n ( l 45a 55(57) ( e 45 56(59) a I ss~sy sid s vt sw s-is / \\ Rev. I .e. -wa we,,,- --w

Specificcticn 8031-P-364 Appendix B TEST POINT INFORMATION System : $ - Fe e.dwa:t sr Id e o.t se Dra.in Location : Out6ld e. 6ont c ) n en en f Isometric : SK-M 5 ~5 'A. /2 4v. H Te st secti on I (TSI) b Calculation No.: J-1y - AO A ps.~.S.01 - L oneg -budino I qc g 4#6 Gl a-n d 6 b wr e.bo b6 l i c.onnechr2d le o ha l4 bold s ConSguro UIOM "" g e hown b e 1 cc v SI mv \\ 53

05.. S.o a - C lt c u m4 sr ent c~ l ye~y e S'A o's b o b s.

lh c.o nn e c,t e d c~ 6 cm s i ny / 4 a c,t i v e eg c p e. os..s.c 2 - C : ec o m4 etenblwl e o nn < e t e d e s cge-g s S 4 is t o b e \\A l s a ng e. c-ch :v s. 9-c-g-e. PS ';6 04 - 6 h e a-r eg-~ y e.s S 5 w n d S G cur e ho b e co n nee,t ed it, e ha IL brld ye cor, 4-iegu r ceti o n c~ e %own b elocv 1 65 ( 57) 4' n v SG (ss) i 3-16 k Rev. l l .y

Cpecifisction 8031-P-364 Appendix B TEST POINT INFORMATION system : 6 - PsedwaAr er Hecub er~ Dro. *'n Location : 6o t 6; d 4. C o n-bo.i rym e f., b Isometric : SK-M-3'37-JEev. H Te.it 6ec.t!or, i LT61) Calculation No.: I -l 4-20 4 D s. . 6. ID - sh co-r yc-ye s G 7 a,nd S F a,r e t a b e c o n n ec.ted in a - ha ll-kld e ws, g S l, e t.a t 4 0r D S, ,6,0 4 A I s-J.7 m.v. l l


n---

Specificcticn 8031-P-364 Appendix 3 TEST POINT INFORMATION system : 6 - pe g g w n t e.r f e s.b s t-Oroin Location : Ogt9ldd (- on-bminm enE Isometric : SK-M ~33 A Rev, H Td W 6 6,c,D io r7 % Calculation No.: ) R o A gy A+Y - 2. ( Nor t h ) g* A-I 515,5 4 m. s i g,,5f g 90* slo (SI L) $9 6ll 5 9 (Sill-510 5IR I i S13,514/ S '3 S H1 A-6 ec.t.lon A - A Side V'e v Sil Gl2 .n 45" 515(Sn) 46ob 51f ( 514) {I i i _ J w 59 Slo Top Vi e w s-I G d m.v. I _.~, .~.

Specificctien 8031-P-364 Appendix B I I TEST POINT INFORMATION System : S-Peedwoter Heo ter Dea In I.ocation : Out sld e (, o n t o ! n en a n-b . M Isometric : SK-M 6 sx T e st s ection A G 6 A) Calculation No.: I-/4 A.OA OS.-S.os - I-e ngi t o a c n ~ l ye~gss s%nd S IJ wes to A be. conn ected in ~ I,~l# be:d -e 9 c on4; gu c c t t on identico-1 to t hok u s e d for O s.. s.O I or, po g s B-I to A Os..s.06-G;ccut m #st entic~l ye-9.s S 1 o is t o b s e or, n <.ats i eu s c sin y s. c c h !v s y e-g-s. c I A Os.. s.07-Ciocv s n 4a e n-bia I c o r, n sste d. c-s c g c g. s. S I 2. Is t a b e slog le schiv s egg-e.. os.. S.06 - Sh e.~c 9 o-g-s s & I 3 nnd 6 I 4 cur e t o b e-A c o m e, se t s d I r eu k. > \\4 bis d e-g con 4;gurut lon id en bIcc / to tl,c2 v s e d - o r DS. . S. 0 4 o n fa x g -c. B-l4 D S.. 6.09-Sh sc-c gc y s s S 15 o-r, d 6 I G cv n e. h o b s c o nnect e d in om kalf brid 3e. con #; yvec tion i d en tice I -b o bl,0 -b Vbed hor D S. . 4. 0 4 o r, (:7 e g. -e B - l h A l s-ic) A mev. / ,x .. ~.....-.. ~ n..

Specification 8031-P-364 Appendix 'B' TEST POINT INFORMATION NOTES: XX TX'.T. l (i) DL = Dynamic Load Transducer (Strainsert /[g } load sensing clevis pins) VA = Vibration Accelerometer DP = Dynamic Pressure Transducer DD = Dynamic Displacement Transducer DS = Dynamic Stress (Strain Gauge) (ii) Sensitive Axis (iii) System Identification (iv) Instrument No. 2. Visual inspection not required 4 3. X = East Y = Up Z = South I e 1 P-ll5( b)/14 B-20 /{ Rev 1

Spacifiention 8031-P-364 APPENDIX C Stress Isometrics P-115(b)/10

Sp cifiestion 8031-P-364 App 3ndix C 1 l LIST OF STRESS ISOMETRICS: Drawing No. Revision SK-M-298 J SK-M-299A R SK-M-299B R SK-M-332 H SK-M-383 E SK-M-384 E SK-M-385 F SK-M-1500 M SK-M-1501 L /{ SK-M-1502 L SK-M-1503 N SK-M-1504 H SK-M-1552 J SK-M-1553 G SK-M-1554 M SK-M-1555 F SK-M-1556A P SK-M-1556B N SK-M-1592 L SK-M-1794 N 8031-M-4-10-13BC P-115(b)/14 C-1 Rev. 1

6pec$e'ccbl0tn /,', 6031-P-% 't AgA l 'k-2 10 4 j}grendix C p 3e

  • ze f

'i /' +" t,, y p iA?/' R p'i. 'fo ~ g?iY s. 5 A i + g.gl +;o..' g -'/ 3 b '0h 0 e,. f S.# < Q ) .6 S. 9' it

j go Aveitable On DETAIL I s

'\\ ierture Card (,Y,,c, w g,,,,,,, M. N,,,,y,.. l' I 20 0.~ ,' ~' I AE, I C E - 104. H TR (lBE toc OPPOSITE HAwo ge A j h ) Q. 7."l4' 10" { l" ' $.Y r .A U_. L / EL. 26S'- O ^ t DATA REV OATE OV REV DATE o ",i uns N D B D-l O2. !! uA Al0G GR S APERTURS 'l u rtmeAt. . T,cx=ess ii,.i uoo-CARD g= ""' *

  • a "'

mm' =os 3y r n m 52,Ress.,so C-2 I~ 7:w e \\ ( ii 'a.,,- %..A -,,,,,, g, j m. 1

r STIESS APPRQvf.L$ REV THERMAL $El$glC N fvF

  1. 'k '

3y REV.J NOTE: REDRAWM ( SEE NOTE ! ) Ig g '\\% ADDED Pt 06S TO Fe. INool C coNMECYlou S Pelt. FA.6 ISO, ADOEO PEu ETRATIou I osu Tl 5:#CATtcM l un't. ADDED PtP E SUPPcat.TS 4 Q'I* D DATA PosuTS, DE LETE D PRESS ThP DATA PER., h e3' STR S GltoVP N l'lD-SLA W Ms N ' g-lb5 T/ M # # oW @ #e R. E *# 4 b I 1 N MOTE: lp 6 4t. o g3,o i O 'j 1.Tws owe.. SU PER. CEDED '\\ ' pjgt -):7 .I f St-M- 283 8 REV 9 (ll"w ll") r/ " C %'g'e u,a 4, p ). I 4 Y* REFEntNct fl f go(e [T [4 IO V M-OG Pil b. D N M - ISS) P PING PLAu AREA 7 ,\\' .g 33 I g (d - M.178 PtPIM G PtAN ARGA G. J f

  • .g.

oso lo2. - t + FAs Iso g ,FE DSD-Io2 - 2. '/, f i oso-l o2. - 3 s og. 4 li %f

  • o o

o 3 n cat c Ne l-15 -5 lA 3 R 4 / .'Y n sf. { $' = g 6o-6 70 2 9 g g 3 i n C ff .h-f ge of 8 ^ MODE DESCRIPTION 'N D .pB ob 1.0 ,y 3 g, ,c ' MODE I ) 30 p.t MODE E e MODE III 8408140326-O % n- ~, ....n

,,',=,

,?g = =_. f DATA REV OATE SY REV OATE BY l LEGEND lw . l w.= [g= maa 4 spa ~oaANcEn BECMTEL 4-neoD wANcEn SAN FRANCISCO dr amma UMERICK GENERATING STATION L

g. curoE UNITS 1 & 2 PMILADE LPM 1 A ELECTRec COMPANY I

% $NLE6ER F W. FROM HEARERS l AE - IOC, N 85ST8A'NT I BE - 10G i i CE-loc. To f ) O *Aacta nuweta PEAcrcR ELDG, L O statss0ATAreiar l-- se31 S K-M -298 d 1

} I CI C.C[l0t, FOR CCH TIN tJATIOh! f ~ Ste.100 54-M 21 } 903I-p'-% e.( g, i f / ~ Ig'd l \\. ~ y ' ot. o k 'j'th b s'f (, ' s,Y Q ( ..'i 'f y '. / )'0$ / g, 3 ) g d' O DET 1 ih' J.# ' (# 5 c -g pN ,s ~ .a ,j NO 6;,' h p 1 49 D.10

  1. 0 toD

,5, .I Atuo Availabic Un F Aperture Caril ,h6 04 D)3 k ,O.

  • p 4'

Y ~ g " /' } >#g I ) I w w ,e> fh of. ~ A<$ ~ ~ w;io 4 ,e,"o W. Y '0 b 03 4: 'lo 't, , 5'

  • z Q,'

h Ehg+ l / OATA REV OATE SY REV OATE O'

)

o" u~s m DBD-lO2. APERTUIq! '! u~na'a' ! * *^ W=m mem CAng . r-cx~ si n~> w i.s= uw-u ~ m O.n~i .. no-am s

  • me 3y r

n m C ~$ gj naiss. esio = rauer exe. cDue. innaan ,=I a ' ***'lit onnn [6V l

1 ggi v. .g. / 57;:Ess ApenovALs 1 f1)I '. I mEv THERMAL SElsMIC y } f 2 f.:4~c'-)*s-N - // ( 6. 'o + %g<g - h [% 'o

  • e REV.R. NOTE:

th REoRAwM ( SEE. MOTE,1 C'l b C ADDED TE CcNNEEcTio45 ( LU(= 5 PER., T , [ h$* ,,N ' g FAB Iso. e as ( AQoED PIPE SUPPCRTS i DaJA. .\\ gB

  1. c -

PosuTS FOR RED:oNCit.l ATIO4 g/ 'o

  • o.

mo 6 % og DELETED vat.vE. PRE.s3 / TEMP DATA t=.s w'6-4 PEft. STRESS GRou P 4% sue. - up, e 0% ca.ecero guy.go. grrog yeusqqc.AL. to M HA W N.*-MC4fk*AS d-M2". 8 ' f-0 r' k T 01 L. 4;g Nc. . pB ' O g/ 4g^ q)'g NOTE o, go l r

i. T m s c w c, su psu. CEDE D.

O* g SC-m.199 REV n ( if's 17'), O.' A; REFERENct T 6. A*,- O f. P f I. D. N As - 16) PIP'NG PLAN AREA ~J O* p. '+. CBD - 102-I FAB r50, e-ogo.lo2-2 D 4 oo 5 OBD - 102 - 3 fAF.$f W'

  • Y

%, +% g D60- lO2-4 s s ' ' a-g.'D p,, j g M DED-102-5 = C* '.r - n cat.c., N a l-15-SI s. b. o isFa.E.nroa.rion,oFiso tATEsto o tv. oa rnt c e+ H ? g3 E=sions su r a%o*o,., sam - m3 q'. J MODE DESCRIPTION 1 + [h s-s'b t N w.D 'y r u00s t 3. MODE IE 4-MODE III 1 IsFon A F om v Fo THE LATEsf otMENSloms sEE sE3 -f.PB 4 4 mes uor eme reR se.. i m -rut.T m a at e sp:n R 4 0 814 0 3 2 R -C)7 ucccuns n.r.md cuer. g 6 N e No. 1 SLA.

n seu av g mrt oc a

= \\

u ll oara nEv oarE sv mEv oArt av LEGEND w -

l-l-r enE 3 ll l S. seamc A~cEn BECM7EL 6 4-nacio wascEn SAN FRANCISCO

  • ANCuan UMERICK GENERATING STATION UNITS 1 & 2 l
a. cuioE PHILADELPMt4 ELECTalC COMPANY l

I n m % s= men FEED WATER SYST3M FROM l N "'57"d'a' "G.HEATEPS TO REACTOR, O waace a au=*sa. Psu I O statiscaracciar - T 8831 SK-M -299A Ps

r ~ p f, f'dC$$ICcAECl'1 mc> 9f t e.n ~ r s.).,,.c n C { 90)I - P-3 h '{ ~ . ' ~ ,/ I Hp? fgw - gg, A ive n d <, x C. i g.yg f y pS ' .6 IR'/ : i r. 's-D G/ - 4 i ^ \\ /s i l g_;jp b i1 Af 1 ..,.bh$ h' ? c' ([' .g. .,- o A (ryp,m ) .... a. A ?a. i + /. a f..: \\ j,. A. ) / o ,s / ', \\ ( hD.y $',J;g gi S.4 A 4 ~ N .q ,f QTi p G%~. 'l.0gg9' htO .o - e .s p 9 Car h i 4 5 .,G k ,I pB.[ ; r .abv-,9ssSt. b(l ~ bc7 M4 /I\\ s stoa

  1. 1

. x 8

S
  • r

' q N 'J'f,% \\,R In L fil y ... ~ . qv.Y v., l' f)$ ' # n.{ 6 8 s M* g' .m/ L . A(,. y ' :ff . > a. 'f x m,n kY (0 / 'c V. 8v.

.Qy y

'\\'>f- ^ K' w4 = >, ge% . i :. -v - .s.,- u-M., .5 t NN W' $ -t ' e; Da7A aty DATE SV Rtv OAft d oi ums ** DBD-102. M fj wart = eat

, ;*,W..,,; ;,q[,;

8 "*'c"5" APERTUI$ s LINtO D. 04 'S 3 *.G 23;3 !4 - CARD 27 "00E I n ur 4 4 1 PAIS$ PIl$ = rio,, ( 5 f., co,,,~,im i ,i "' ~ s...., g

  • i woo osaLa$t m l

q g 1

I en 1 , h. # I srress aremovrts C. ' o . h t t f .4 ,e c7 gs,/1.!F, /- Irv rwezzat seisme ~o" i f f 'Q,3 - Ni P..,C~ = U6 @6 N((,Q C,g,'N., opo 4 $-p, '9 ' \\ ds f ' lp e REV.iR NOTE: lp. e9 a. n' g i RECRAwN ( SEE NOTE 1) C4 At cco TE CcNMCs'.T'Otag # PU,)da$.'~PER.. 3 s . p.'S $ ,,pk [/, g*,e " ' i" sine cm..m, em g W# fec (( .gfgg3yhg f-[ M f-A FER <r,o:. STR,ECS Grot 19 Awax. up.o' 2-5 %-M-tHe wu, w,-y ts-m.c:4 weep t%c.4 c. d 19 1 -5 5 -51A we < c+u t-o ' p c r. .;; " d(j m!' Mw I Tr>,%e.uc h,, w.succo f, 9 g. c ?c,{c. g YFCM kJNEPot. To y g gg,g," ,y% A. ,g .y-c e p,

  • /

.' y. stil M/ 3

  1. N2g '? 'c,,

,,,., 0 - / " ' > -- v ~ v

0

, f /, MOTF. s og i

(..
i. Tue, h.

.o w t e e- >it o .,,D 'd [ g y W mu. 2M csv n ( ar tr), s,%. e, s --,; + I Ai.; . N ;., s..- atacarses s I s,/ s,d'," Ag. og = < ; ;, Y ~ .% - l 6 ) % h " A

  • .A. s.ne. g M.

s.(' ,g,,... ',Q d ti. - V. - I ^ ? T Z.. (gN . g, s, Dia. D '0 1 - 2 N ' o. Q.;., h. ,,jf'4.?h'F deb 101 4 4 CED - 102 3 x af, + '<' 'b N

  • \\

ee. s

  • ?

's c' s n-c o 2. l e:... s Y. d Y 't' CAL.f.,42 l-15 51A .<,t/ l _, &, a 'f

B.:

d ,/, t. r-o. a pyr s.e ~ q,-- ,/ 9 / N,,. , 0;/ - o e. m,. ~g -. a;, MODE DESCRIPTION 4 ' 'io- .. NN~. R' &) ~ s,, 9 ' u~i.: W', 1. 'AODE L ' q, V MODE II M MODE III % f Ct00010 PCRTION OF 150 15 FOR REF.0%f FOR THE L Af t$r Olutms;3N3 5tt ay snu. ':n - 8 4 0 814 0 3 2 6 -O b Y I I i 6 .:(, 6l r vr.. >. e. - co c.w Hr,o = oar 4 arv o.ra av nev cars ev ticsso - l... l - :.-... :::: e-sramc wascia aECHTEL ] s a,cio wascg, SAN FRANCISCO

  • 4Nce.ca UMERICK GENERATING STATION UNITE 1 & 2 cuics PHIL AOf LPN14 (LECTRIC COesP AbdV g

g g F E ".'. \\*. '.T.;; 0 ' '.., ' 4% F'Rt P.\\ H "EST"*'NT m,, g g --.7,..;.., .g., ., q I O '*^Nci a Nuveia n,o O srassscaranomr

  • I e

so31 S K-M -29% R 1 1 I l

- ~ _ This drawing and the design it covers are the property of ' reproduced, copied, loaned, exhibsted, or used exc M 150 r s o. e t .I ,.:.J ' +-- f ('. N .J D. ' ', ~ f., cf l j ; vs:. s j 37 9 , ' ",.. _fr .y...Ete s ~ d-2 .. g. ; - - - - s - _r w .,Qy,,--- P dry.6;0 5.,/,b, j s '*' 'o. ,H, N 90E '- ~ ~! 'a ' a* i

9oto fa f,

A ,- [7, l0.... *,.-. 't' r ~ ~ ~~~ ~ ys ~ 4 ~l96 i b. k ,,,,, - DD.K.'S'.cl .?,- gg g. r,, I j'jh N

  • ^'I

(, i Cr q, 4 '\\. . 7 HI - 'y-} ! ..:-y,1g;-la-(g g.R ).9 %,.1

i h'N

?. Ibr. ,fx.;f' \\ ((n$ h,\\ $. ) I 5 . w,, .,e..: e. t .y.

  1. 3,

v g,..? - '['g o .g ~. NE ,f '/t, g ~ p.gh,, 'N - 1 ,~ i q $ je,,~ 7 ' i Fs Fo Y 5 o3 \\ .g L., '~ b y /',,# t g R EF. D WG s'. % g' op,. M-04 P4.lD s 'M - 150. AREA 1..,J: d M-158 AREA 2. TI ' dEV.14 9 v APERTURR,.m 'M-159 ' AREA 2 -?'; r. /- . I7A AREA 6. :- i%.: .. ADDED PE.ME ", -[l ', M-175 AREA 6 ,,,. ;-.,, go o p,4.e{ ~, CARD e' # '.. I T ^l 7 l ADD D had ~ O D g:.. - i. '. *. ;.... :... L;_. j. 3 .%.1 'M.20fc' pos.i,, t. 5.r..'N 1..; p...;'. '~ ,c. _,:. u. w s. e.n ..t. : r., .,,.g i. g.- ;. g ..>gc Q y q .x

*.;g

.O HdNGER NUMBER.O sTanss o^T6 P0lNT , ggpgggHANGhRf c-5 ice s I - 8 4 0 814'O S f6 -C) /.

3 /-F-36t/ f co- '083 ECHTEL. They are merely loaned ami on the borrower's empress agreement at they will not i, l $snited way and private use permitted by any written consent given by the lender ts the borrower. N y 6 t7diy C. i /W W"T 2. - 9C-M-2/4 4 f 297/* ~' ..x q-@ C

4..

i.- THIS STRESS ISO APPLIES l AS FOLLOWS, UNIT No.1 \\ UNIT No. 2/ D .! _'t , '3[ l 4 A i AS SHOWN YP. HANJi j g i,;-p.<'I.a.b I f ESD.tlG H IG p ,gt q- / HJ0-105 nJoj os-g 3',3,, S

P J" oss.

cHKD. encit erE L. / \\ I h N i ). q. ".fi&. h.'.. i-5,$ M. 6L ~ ' - Poi- [O M)/ ~ t .a x.i qll.HofE6 R ESS. COMED .'S -a n- % 'l --&. ju ' h.,Qcl0%hp't'$ ),.fa ' Q t, d* 'I . =' [.- -' h. - - K' D h e% g6p . g-s'. ( .sy,. s a 5"d 'a ' KC.hhhg .Y v?.,,,p, ff.3 ,.lk#,gh Y*- N ,\\ a .c i

3. 2,.p.

n t ' #_ lff. ,.f h o. & {,., ~ gggv age&}gg. '.l ' V ': Wl 4.(g%&.ge g gr,.4. Rag /; %y },f 1 r- [ g h ..'.:A '/3: i - Lt' 9r/{'jE 'f($ @ hl 1.[ g f R.Ngb,..sgisve,p'-To: ny m e em er . 9k. (N -8 3' 7-h '^20Mid g lg <, - s 9 .I

d.,. T'A'.dh. e y9 ;. -.s.q.., c,3

. 19 is.// 76 I y[.. i m,,.p..'t [4..M. s' W < < ~v y , e '.. j i' L Polo A.'RFnA5DSHQWhlJ-EB.. e,- j, W_.. ./. <.a.; .a . n. -M 3Aprw^aarr r. v O ,@7 A L-2S-B 5*.f -* 5k-- %- J; - ~' d I' N d ' N 7 y .\\. 4.y ^'*s, ' '.,. 'o . w pg&,,; a~ 9,3 9_ 7,. e q. .g, .I Q'? A/ Cl - N.W..P W P.N gi Cp' ~ 9'j.j' = W' p6 'gts. P 3 STRESS ANALYSIS DATA ?.[5, h ~ N t/ 'g f.h: ' SEE -$0MU MATERIAL g m reup..F / PRESS. PSI.r{,vd*p'fp.d h Tsa (,,. [ MOD. OF ELAS. ~. PSI,, [M /k M d .-r' ,Z I. ' - EXP. COEF F. lN /100 FT. 'N , NOTE; 'CL ASS H BD" EXP. COEF F. MIL.IN/IN -~ ^ J..- .R..-MATE R I AL: SEA MLESS h+ b % l D Foo7/Pe,N42M.Mht .- ~ .~fAETN 'A-106 GR. B 1 's~ LINE O. D. (IN) ' g M ' <' ?, LINE THICKNESS (IN)hM ).$ M 4 Al2/.F54. sygc, b "f,CCASS'R'd D , FEM . in s ,e-j,J ! bgT.ER.RL: SE.AMLE55 ' S .) A - OW C." .u.p.- .. - 33 5 G GL. p 5 --+-... w.. N su,. _ .k'/[~:...wv. r.e. .;<- -,w..q.,-.g opppg e YR.I.GlkHkNGERj -d-A!4CHO [," ' -=-Gul0E,[.j'f.[ kQ"3'f ~. j 5 .,.. ;, g y,p g -l., A-m ,%wm,,

-- --- ~ -. : r :-- - r-1 I, 3 This drawing and the design It sovers er's the property d M.160'. reproduced, mopied, looned, exhibited, or used exempt in ~ .~. . i. - a\\y ,, ~ ) 9 a .t N .N .i ~. .-x ai a: v. 5 g' 3 .a ,y .;. c s i 4 ,.,m\\ 1 .. r ei.,1 y

3 V

, hi. y '7, . e-.: 1 6g., ,g % 1..

,f.3p #

' k.4.qt. (. b 4 J mo .% 'o.,.,% ' t + .e t. .D :. :. f u.=s, su. t.. y%;. - g, * ~. S a. y,,;i,, A. - gg..: t ,+ yn y:4 V s. q. ~ J,. 4.,0"' g 8 gro -) _ ggQo I S ~ . ; s.l. ; g ,.p. [t.9 p, m. .. ~..

g. gi.

g. . g 1e 1 16 'V M s 1 h A[ailable On

~ ie 4,....

.,.,Y, [. k U I \\ s 1; N HAperture Carel .. : "y .sO ( n -..,. ~. 03' lbo.7 's.s ,es ..), t 3, 9., ,O) ' A 433 .m .., i,4 i, , oo H8 - .h / p. n .s. o o,o, 1 9 5 .,, ps ' ' [.'

,-ec. W.

e a <DO Y h i S g y y 00 . og g 8 Vph 10 ....'. n, t.. : n 4 gn 0,, H7 g .e 0g; e T..;: #. ..: c... 3, 0 3 gf .e, o,.

Yg4 Yg$g.

.. $... :l :.: :.\\;. *l.*

  • b S

+2. L . 3.. .(.. 1 ,. %. : f.,.g. ,o. .,.. a...

c. w.

.g y. .g ~c. $...O ..., _ n.::.... ~ j e l;..y , u : a. .g. . s5 0.. f ye, y .:,. L.. . ~m.o.' n- .i ....,.~. a .~;..., ..s ....._ n4. 7o y _ _.._. _ g.,.g p.e f.'..e ..g.c.. t -f s., 4',%y.;,3.]f,aV,,,o* ., Y, ' ' .. ',?(.'$ ..z. '.., ~ ~ ~.: ' . l+., . s 9 ggg ' f,. : N.:.;4

f.;C.

.:: f ',,,,, ' M\\., e; # g ;. e .o "2

  1. 7 y y

.,V,. 1 4p. 4. 9'.;hN'N. IM$M '. 3~ a,,5.'N'i,'-?.' S'. D, N5W.. Y, b..;'g'.[.. S Q.)... .,, g@...y g ,.:m. ., y.,.. ;. %,. s. ..n. .a r J 3 ,q ~Q~ .,~s.,. . g3 .; b.....

.t. '..

,t. .,....s <'s<. i. .. ~$ r e, % Tt... ::: : . ty n, s a ?. 9.:r yM a ';-~~M * ~.n :" i ' :.. : :: } w *- V 3, 9 ggb t c' i Q iy. i.y<l.gdN'$k 8.d+$4.T ' i. %<.T..$.b. A2.45 Yi.I .: r .v m;sq ;.w.s.wm - .y. >, y. v q: 6.- 9 y.r. } $.N-5. c.-@.J.Mh. ..I WsPRINO.HA d,ER he,,a.4I8kt96wiaiNmMsu4as1snw

z ....... d... . 3. e c. ' l..ic M ot 7 4r EL. They,are merely loaned and on the : e.;__'s express that they will not be Nmited way end private t:se permitted by any written consent given by the lender to the borrower, 3, p )g t ypen d he. C ed.H REV.4 NOTE t i ~' Appsp pgkI67 l.9. fbo?/MA 46l, \\ v. .3.1 Mos/PGAr429 $ f'co3/F9A-4% w ,.1 ' TMcoRP..FCPi M IS,54rof SH.20F4

c.

p / .n L l I Q

l. \\ ;.

\\ N o g [ Iti' 3 J i 43 l '\\ 1 \\

Dsn.:lol-I Pa.ssoi m.

1 srmsa enc:no. t.ss.2o2 =.<.. :.. n 8 s

.9.?b -

\\ i Jb.;' z I %I s ..g

" \\

ipi EL 21 ?'- o" ..%;.S Y a p g PoyP $ POMP BASE 4( 4 i sW' = 4 r.o 1L 1 I l'((-k.r, i l m S

  1. ele w 1 uAgh
  • p hw,, =,ncm Ag

&'o + $9 15 o. rg i t, 15 l J 7 ~ a... / g/ \\ s' Lsi 1 Gert M rk=~ M ,/- +g-lG = S,y a PES Evi fral ?*.-

  • -4 S 01

.- nooso.usesse A5,..,.jW,5, Ny* * + g Q5 fo ^ " +8 ' gel. I02 A - BTMESS ePP,4 PGrrDUIDM m.__ O g i a .c:.:rnArm-uP, pet-rtsopr -- - -_- l60 . 4 i-g$ ~. " b_vnt.v. e-oeTKneweEn: .9 Y' 's l'f ~ ~ ,4* i Mr* ..., ( p. STRESS ANALYSIS DATA / i, ')~., ,,g Ig -", - MATERIAL." N A", :, I I ^# 4 y L 5-0 A - te An.-s-.m ,t J..."f d =, g ,acw TEMP. 'F / PRESS. psi. ,f . q...t y ..4 1 e ., - - - ' -,---p MOO. OF E LAS. E. PSl N,[, h 1 * .%'t ? <lp l 0 . L-@%,.% 'gp EXP. COE F F. IN /100 FT. 1 gr" 8

  • i

.f. [ I / EXP. COEFF. MILIN/IN

3. -

i. d e..'. ' fT T" ... '- ~. N( W !" LINE O. D. (lN) .78 \\, g' '.[.'... N....' - d.- U, 5 h,,.56',(.S. -: h;f.,445, <c';g,',, " Y" 4 *.Uh ','N,,.,, 7 ' i LINE THICKNESS (lN), f$ 'i ',7 FEEDWATE E Froy,( j -,,c,;.. ,,..:.s..,,._.. ...r ? .a.- 5.: #. P.. -,w,. m

c..,#

p y p s.) A P. g g y a... g ..f ~ F.4#lTR., \\ E.-~lC'di' d.h..-l,g? 7.,*f,E.. .i '@ MESSDATA'Polltf @ HANGE R NU54h,f.R . l Jos me. . ) onAwlNG No.# .MEV.

  • n k h lOHANGE,R NG.,.,'[,

,3 OkON, y,f -,8Ci31 ]. Y ,'f) h,h-5 Q D.$e 3.,. N. N. $ M M : 1 ' M b N N :N ' N '1 M." N I b M * '# ' ' 'N i'NI'~ WEI'I

Thl drawing and the design it covers are the property < I w j M-150 reproduced, copied, loaned, exhibited, or used except kI i [ p .N i [ 3 ' h (hl

== sf li q .Y 0, O 0 kl \\ , d* I hY I m / / f 9 'y e 9 g _ p' 0.,6 f Ab f C p* s .e ., ph .l

}

1 = o, *. ,. ' -.y Al b 4 = s e c '.',,. *'.:$u - @ % $ @. W V .c. e -i$' - 95 y3 ,. Q pMAG.*

.?.

.a V .'h^b'h -:-k, D+ ' ~ <[i..i,' h, p

  • L t * '? ?

a's:.'i H .r,

  • t >.

w. ;: :. s 2 IG 89 .a.., . 2;. Q4 ' '. ~, - Sa %:* $ '/o,'

s..

e D s Antiate OA g Apcrtitre Cud t, - pyERggg i 45 ..:{

'9 l'

~ CM HO Hl'1. ~ w s .,r. A p Ag gy..., Q .... :i. > :....; p,..: 9y a . ~. - + l A 7 i 6 e gP'.- 'q,..,. .n \\ ,q Q ], 41 ,4,, / o .m ...n .3 g,a., p - :.y. 9 qu-9 ag. 0 0 .cs ,9,- , r ' '.j '0 ".g>p.0 ge,. . -l. 1 1 s.

  1. p.J jJ g

e 5. g$91 9-7..,..c-3 g,7 . -e-amua skuasa 5 ?.'s4# 8 I4 64 2 6 -ot )

I 7 Ve d bbio m BECHTEL They are merely loaned and on the borrow &cxpress agreement that they will not be 6 6 3 1 - P - 3 6 L[ er a e limited way and privat use permitted by any written consent given by the lender to the borrower. grPwgj$ c g rey A WOTE: L Ap9EP FENET. l.P PS47/PSA 42.Ce, Fe/gtU,.'s.4* 4 <! F'oc>9/ FSA-El ~ .:lHCOR P. FCR M !5,5 4 G F SH. S OF 4 22 REV.. E We:.) H11 tootD Hsms. A o,P. m STaess swe, A %Ft, GU108NCE N-OP. NN PMEETO,/ ' TEIrr1Fl. dt ~ VALVE CATA,. ADDED M o.A... ...REv'EREHCG'bvJG&o CMNGED FROLINUMERICALTD ALPilA %C.,11UMERICAL. s . fa ~.. - - ~ ~ - ~ ~ & E ~ ~ h \\. Y ; h ' s s.., ,c & y k,* MEFERENCE D%GS. '(P Trt.: CG P a 1.D ~ M _ :. ~. M-t85.. PlPING RN4 ARETA 7 l. _Q~*.... M-18 7 : ' s ~ M -l8B' 3... ...J...... \\ .\\

Pf'O. lot-1. ms.
lto...' _.

g,4 .,/\\ <c'0 - %j y_ ernaes.a.it.c,.. no.._i-i s -m:n.. _ s [ [/ t/ l /$h Wh{jifoyV-JMrf th gA, 4A g l A 5%Fa5a % & w seat %ei f I"g g .j /3\\ 'l4 il7 Lt cut. v in He, N, 7 - s, W

.9 ev a.

ots c <, ec 41 f,r-\\ p(.9.pi L' ? g. rg n \\' g O g, ), \\ , j,, STRESS ANALYSIS DATA t N, ' gl 'fgt[ 1.c' MATERIAL 6C/-M LE%c ASTM .d ) i A tog A R.b g, , 6p,ff.D QCu TEMP.*F / PRESS. PSI N,. - l f w. C gb I';. gA ' ~ MOD. OF E LAS. E. PSI . / (.* i g f6-EXP COEFF. IN /100 JT. g 'I' .h 86 E XP. COEF F. MIL li4/IN f d 6 3 g f,.L Y' V gg, LINE O. DylNI 20' { _ l

>m O

LINE THICKNESS (IN) f FEED WATE R. F RO M [. RF P. I tsp-t o t To ,. 7,,. o p' F.W. HTR, i B E - P."4 OsTasss' ^T^ rois1 G.H^uatauuusen t, @ MIGIO HANGER h1tNCHOR -EE-GUID E* ~ * * ~ ~ 8031

  • SK-M ~584 7,.

m. g... This drawing and the design it covers are the property E160 reprodueed. oopeed, looned, exhibited. or used except in i j , - p,.i r 1 t.. p a (J 5h N - i IQS o ,.i h' A I.,>" r . i..u AS ,/ /M g. Y H )

  • V M

'll. Ct, pub '."g pffe 4 'Q' A 4.o Wf Z 'A up Q 30 9.o l A, --- - t " n12 A ^ pod g 9 f f.9 ~ ~,' 1 .4...; .h$ \\ '.t. e ,.g Q ,f [ R4sy / As o fg y$ Y \\p/ 'I a p. .h }$,'$$f% '.) q, R49/ ,/ 4 *?

  • e

. l. s. ', + i',.'f l :,';.;', H2l cas " / _- ] ' p... ulo;s:.

  • :%.':$f i- 'p, -::

.. ~. .?) 7. 40'0 ft ' ! i. ' ';. .., y. ..qt

t...n r-APEKl'Uld.. -

y (';$'f '- iii'- of O./ ?.. E.' .. CMlD .[ .t.; ? .+ .I..g..,.n 4

te r

1 V,. I,:., d.. C, .y l

  • ~~ ^ s

~. - Q STRESS DATdPolNT. Q HANGER NUMBER' + SPRING HANGER ..... s -... -.;.. .a...

[ C7g Gree,;#-ic.ut:,c.w BECHTEL. They are merely loaned and on the borrower's express agreement that they 'will not be GC3 I - P 'hl,8/ a limited way and privete una permitted by any written consent given by the lander to the borrower. 4pFegtgg C geg,ff I FE.V. F._ FOTE y. A . ADDED. H9FC, 4. D.R >ER. ETF.E.C6 GM, J4 H6R.. f-rVIDPNCE_..fWSFi,t%-UP. DELE TED PPEL.,5, /. TEMPI f' VALVA ' DATA. CHANGED FROM WljMERICAL TO. ALPHA NUMERICAL l REFERENCE iCwGC. M-oc fS'ID $;'\\'S5' )*tPIN(7 runt _WIB6,. ~ -- g. g s 7 - - _ gr;eg ~ gn/ t3 a ~ n. ._.D 8 0 - 101 - 3.. . CS C. l 1s-2o4-N

p. g Afao lvailable On Aperture Card 26 d6 Y

$6N$5.Nkh W A%lYt5 A HG 8,V W8 INN;l'W^* f 'G, hy I IS', 9 g6 4 [f,gyl;- }Q, PR/.F tCTE ftS m a go y .f g49 g,,y L fg i i K's (7ATk .REV af ex pss CM regl /,, [AqN,, 3 ~~ f Y 7%t /(t ( /Ofc p. d 8408140326-/O 3 ' STRESS ANALYSIS DATA D .,W 5,/, g 6 -.- MATERIAL DEAME E A1D a '4,,,4 -[. 3f6 A-l O 4-GR B . f % [.~ u m ~, Z Iq, 'j6 0 TEMP.*F / PRESS. PSI ff A .N,'. - MOD. OF E LAS. E. PSI ./ r' p I H3) l3 l ,;0 pv EXP. COEFF. IN /100 FT.

jsT,

,1 ( d' 3 9 E XP. COE F F. MIL IN/IN ,3 8 /05 6 ,j . (* % g6 fg<

f LINE O. D. (lN) 2Ci I

7 gd g/ LINE THICKNESS (IN) h4.-f. 9 f't, [ * "$.L fl,gdb, f0h/ FE.EDWATE.R FRGt4 g Il ~ l. y 9I ),, R F P. \\ CP- \\O\\ TO l 3 D, FW HT R.1 CE.-V.)G l JOS No. ORAWWG No. OE V. l $ RIG lD MANGER, 4 ANCHOR 6 G,UIDE 803) S K-M- 585 F . t. i

( ..w, ' W WA [ i. 9 pee l$Ica.tI0h ' t* y T s

~ WD31-P-3by
  • N'A
  • 14'ess-log

/

,t t

O (St<- N-Iso 4 3 \\ er g,4 $ .,#',s# endIX C { j 7f a /g,,,,. i 3 4 e + +, . 6., d a[4 [,. . d,g s. 3 . % 2 yc,. + e+ -m l .)

  • $f,,##,l

'9.fd l a4 ~bf q n d ., "/. A f-l J ),, Q ' f %~ p i s. -4 u

  1. Noft: PtPC WALL THICE.ME%

p# i BulLT-UP TO MATCle G.E 4 g ,,, y VALVE AT INTERFAC.E. ..M g p ,., -.. + s. I ,a A.O , c%s cr s u exec 9 su ( .1 )i ,n .s ~ ' *. k (ny se) T c C 6,8 ~ 6., s f y I 5.... j#D j !) x-7c ,y Il / Af3o Ay,il8Lle On r m - cna 4Y fl L.. - 4 i N DATA R.V DAT. eY R.y DAT. I APEWTO N v EBB - 01 1 A % DAJ 5 uw m i i CARD fg ",.".T.,

n. 9FaW

"^' m u,. . u ih, uno. om zc .c. s.ctskA e/A %. i )' j w I I' Et _ 9 t h-U T. esp, /t4 l s l f 4 o 814 0 3 2 6 -// 11. i l . g! ['\\ %. ~. gav I i

iI.~ p %.- w k " -%, M -j--- q R-a- ~ ~.. _M sTness maovAs +

ev rusnuAL seismic l

pp. ofc ( t ..i $8 ua( t. u s-to 4 ts somsun ; h' C f ,M i e sx-M-2.157 - r- ,0 .n:. u, 6, o as as ao mum As renom, 4 I d$ Ili p E" Y 6$ h EBS isi 3 o4 is Y 4 . )NG4. dam ook OmD. p '.qf o,g.gsp M i&NN' asy m note

. - y-<

g a g d' h yoED l' PLUG TO EXISTING l' CoNh f. y,,18 -9 i 14AL.P CPLG, PER FAS ISO.- 'l ADDED PIPE SUPPORTS ( DATA PotNTS i i e* g' T FOR RECONCit.l ATI O84

f'.

g 'g ( i DEL.BTR O VAL vE TEMP { PRELS$ D4T,4 c. PER. STRESS Group Manx-tJP. 3 (,. ([i. I' ) e REI'EREN CE S m. i , i. e,. c - (M 1) 13 e 6 M. I ( l. b 7 -h h,g4 '54l + INCL M

  • 7.8 IDINd Pt.AM t,-

'tWJyfi %h i epp sus -ioi - i ~m.tso. nuv. m.% % \\.,- Y Aj ID1., sTatess 'cAs.'cW. i F6t e-is e g , yoyg ' - -.= y.. g a ct., = - / j i, o... n m an s,5= =. ( 'm,..g p sosi-s-20 -t o)-c. ar.l; r.3 3 q +,. o. c . g C. ?.:. L ~..._...L 9 %FQ 6 4 poogafscRerdV :,.g-s pk,- ,,.,m,,7.,. j 4 4, u o s m G.f 7. N M;, a i;~! h yope g-hsawan -,..~ b ..u

~. : -

. :-~..s, :.:q y l I,0 -\\ ,,,,A M SKF TFY.M Mort m 43 7

J8: M N

L 4, li'JCR M**78W-TiY PS af, / "/45 E, 8 teb / "$ 2'q 4 5 4faiffAW s.. i i ~f. .f F QLnL r,'.fyes f.J'); nLt,yy R Q y, 1&$ttRawr Matt * "At86 Y 1%.r' a.nsv, inst.H8'PtA Pint.:

    1. E F.:

A 'nl$Ed."nr1'Isd k[ /[~Y T-i e !?ETAll. Il. Aff/ PtLOCMsD (see 139

    • AP' E

/' % M a, seismo e.t e it a mit e-

  • T4 M

'!A 4*me 4 w l 9.L I 5 T E D l A henasnasses F M w a wr - I-l- l= EE i' C oATA nev oArt ey nsv oats av. LacsNo '=a E c.s. a r m a 4.seninosaucen B10NTEL-Sjis $:. d J. [ WNEM m' i ,,,,,g,,,,, E A,,,cgo, UMERICK GENERATING STAYION e* E 23 } A,Ask mu,,. UNITS 1 St 2 ., ik.,, ', i 5 ouice ,,,,,,,,,,,,,t,,,,,,,,,,,,,,,.3.,, E a m6 H snussen .lSOMETRIC TURBINE BLDGgp E 9 o ng.. Jy s ns.1nA.. s. o nau in 4 a b ( \\ Q sinal 80ATAPoINT.. ? 'A " ' - ~ 8931 SK-M-45y1 (' ~ [ ( Li, N - i.. -) '[MS J.

9 rec;5lcc~'tloh f

  1. 0 % P '% ti N

i l O /g\\Y 14*E (suBB-!OC \\q ts, i k r*nd a, C a- ,,,,,99,+) s. j.9 i 1 v-lR( $ Q. ; _fs' l 1 ?- '3 0ofi u 4 c,' fo ' 48 t,% a,- S#5 g u. gm% m. e } ,, ),'a.

4. n, s.

tL e M

  1. p sg,e s

,, a g l

  • f* '71%
  • &N 4

TI ^ { g 4-4 1-7 Y'% APERTUR$. N F" i CARD p# '. 1 f a f' f .V 9 d l k X-70 ~ ., m ? R. 6? 4 o j -;u t sti.ro it.c s.1 Aho Available On . J. / Ag,ert. ire Caril oATA REV DATE SY REV DATE N t g EBB ~102 l d '4'n Qbl & '/4/g M UNE N '~ ' g' f MATE RI AL M','$fgNl[("M UNE THICENEs3 flN) h A32, E } LINEo.0. llM 2(, g,ggg g Ifgg 4 N p r n a uoo< 59 Passs ma q cw 'l, I*, - - .ic. l 0 a EXP. CoEFF. IN/100F7 j l b408140326-l1 :'? II '"c*'k_.. l l ice u, I . j; .oun~ ~ i E

1 ' STRESS APPROVALS I

EV THERCAL SEISMIC f

I a f e 9 9 UNIT t t ea-203, is st>Peasemen BY S R M - 275fo .c. u s er: s i o m uEs / ? sTorvAi.ve Msv-t l '%l * !*'h,e,,. M,, Kt (u 1) 20-1-* Sn.14 2 as sown 4 [ Ess foz Zoj so ,T,' '1 }ISkINN ca ci o. op. aeri /I EM / k Rev L Norr-N b N' 'E?rTa h la"Mlni08% M Ys;??C % r < 0 <. Q ,,/'. d / m moa -~r ~. N .>.,. y.9 3 \\Qif

    • f,rs Ts REFERENCE r

h J l. j9,,' -M H -ol pi a p (u.4 zo.s-s .g' H - 36 8 Pipig y i Sw. i- + inci.. ) 8 EBB-102 I REV.12 FAB.150 g, * \\ 3,,, ,, s z t-STRESS CALC ** l-CI-226 '++ f" n no,e

l. G.E. MAMGEst.,SEE DWG ME g

w?tX.. e aos - m-2b-I 0) -( 5HT, t. 8 .\\ / t -- 'f.4. ft t f*.4'-N 4 r ? W. P. EL.159'-6* McM DCSCRIPT15tV. ~ - M ,n# saat-asa / b'o. /5.f/ Moos 3-MM/Muh1 M%'5s FCIL M-67% F'T[M T / 'Tg~~ 4 p g e'#</ o 4 2' ns,~."4. f.o \\$ / ")L 4.L Cf r FFV L No FE F? siNa W de\\ ifit RELOCATED l's00 ISS en ri-Gs 44 4. / /p4

b. Tree RgitutD fe4 w"Y 1 mod vea-(a (a f47 4 J i;,

I 9-LIsTEo l A *tn ismomrun awms y a fe ., r ..s . (m w lmm M DATA REV OATE SY REV OATE SV LEGEND ems c.E. PtPWG S SPRING MANGER RECHTEL H SAN FRANCISCO j 4 Ricio wANcER UMERICK GENERATING STATION

  • ANCHOR fL 2s A s/4 '%

fr cusoE r a m % SNuan" ISOMETRIC TURBINE BLD'Ge UNIT

  • l.

N RESTPAINT MAIN STEAM PIPING [byg*p' 1 O HANcEa muusER Q STRESS OATA POINT 3031 SK-M-15cl L'

7,..... 1 .i byec.,,'&co: bion l "Y N ' #041-P % 4 FV $P70 IY l <? ' f's, p e q' h y# c i s.+ + s p g,, s l' , *s '.f f 16 /a..x. A.m 4

  • [, t,%

..+ q. i dh s. ' f a" v. t o l ,9 ' Abo Available On L Aperture Card /, 8 %q % s og? ,g.1..d efby 6 ] TI APERTURS. j> g/q$p,, mg. e.< g CARD d ), x-7A f ' ".$tO 'e + M -Eu l s g 'N (M-4) S21 FO-ll*C-G.3-N. 1 DATA REV OATE SY REV OATE h ,(hs gi UNE h EBB -103 l' /Ah Bl*. h3 Qb)

  • /4/n, M

) Ef MATERsAt. f."; & R $'j ( y liv'yg V UNE THICKNESS (IN) g"w 43E ) i LIN EO.O. (IN) 2(o G.G?.5 A\\ '/fg (4/m S 2g MODE I E M. h PRES $. PSIG / TEMP F ~ /L\\ ] a e EXP. COEF F. INH 00FT !l y$ gg f EXP. CCE F F. Mi t-i=m, ggy, [ MM.0F EW E PSI j = m

_~z STIESS APPROVALS REV THEEMAL SEISMIC ' I 6 DP.,A.03 3 RFv. L Norr:

  1. gl,,f.'s Y 9S li?1?ay'LN,W?NUsR&'MEl23%'5 PP-IOIA y$

.s-06.e nr. Un ca ntuts 1 M mow.. jo1 ~

  • r #ga sge #gg o8 Is"s "c'.:2T@

y. ,i,,/ j$",j 4 E BS-ses EB t of. v 't- ,m I e ces. chao. pyft Wit p, l g b Et. ' e7 / K g g( v$ g g i.e n i., u / g , S' (}{M /), J1 \\ 9 0) ~b ~% P,, f g, cq f.a j nggRemei -. _. - e / M-on P&ID .3 )4 'l b M-3G8 PIPlNG PLAN ih Ee!!b-IoS-I"REV.22. l'Ap 150 + sitzss CALC l-CI-226 s

  • t..

MOCE OES N h J ^,' r.2 2 *) g N.p,', 9 N005 5' DfS/M ., MCCf f-MA)VMUM, o~ [L1 NOTEi ' . -' -~ ,e q,. s 6,

l. G.P.. HANGER.5, SELE d'

8 SHT. 2, ") D w ds Nt 8051 - m - 2D - t ( t) - f. .~ I / e e- . - ~. ,~.,n.- pt t.). Ir. n /h.. - p.k..,%,e. . Eusv.c 8408140826'- b88# 'I'* "**#

  • DE NV

/ ' ' O' M F84 K N NC, l'CR N.bT96

  • Ff ~#

d- - r .sh,,

c. *% ggaggA*?n as va in / "V

,,,,, n. w-.r - m a w w #pp. Y*W55EIII'E* ' nI'* ? Y $h *Y N .) WET *2 EBB 202 l5 J su?EntSECED 8y seen-u,ss J y,, ccntt.tv.4. Me:>. & lw up f,Mrs L V J WEtocATuo rue rd.ar4 9. .w / s s .~. sa, s uw .<. m y e s AV". * * " * ". " * * *,*.*. *.,=:- I 9 - 1.s s T a o l a l" l *"*" .E l DATA REV OATE BY REV OATE BY LEGEND "**8 c c.c. pims -o-SPRING HANGER RECHTEL O RIGIO HANGER UMERICK GENERATING STATION

  • ANcHcR UNITS 1 at 2 ta A 6/,3 tcy,(A

.i-GuioE PHILADELPHI A ElfCTRIC COMPANY 3 8 38 % 8" " E" ISOMETRIC TURBINE BLDG, UNIT *T '- N RESTRAINT - ) o ~ANcER Nuo.ER. MAIN STEAM PIPING (Lipe. O sTRESSOATAPOINT 8031 SK-M-1502 U

We*IN o'M o r, b..Y $D l~ V"3(o N N ii V 99-f0, O pt..s.A.o L.G.A.O ("* N N oy 49., 1 \\ \\ EA 4 m

  • }

f, 1, k, s 6 c,,, "E @7, l%.\\,/c? tA j.r y.. ,g, g, , _\\ S'"/ g. _,_, [p I l-3 BUILT-UP TO MATC.H-G.E. YALVE

  • e-o 4

AT INTERh4E. ' Q,'". l [._' 'w.oa 'M Ng 2-h AP[# cp kea e-r3 ira C u Q1 .? . t,'.) ,,o' /- M / .,;., n p ..l- [ g, f X-7s /' M rese-oup Aggo Available On %g Aperture Card p 0su ro zz-c-s.3

j

( DATA REV DATE SY REV DATE f j gg u=e n EBB -104 \\ A9/n obj A % o t 4 gj==TsaimL 't:n:indh. E } l .s uns Tmex=ess um.'@,1l.m. E i j 3 g gg uneo.a.nm 26 6.r.25 ./A WA '% u l l g p moon r a a i 4 gj mesa.rsna 1 c -r ( g y a r.,, f,g C _ J 2, f = en.coser.innoon ~ n V ,d ""ca'W_,,,,,,. l i ht',(/, f I Mao.or ELA8. I Pet i.84.08140326 g

, ~,. / ST'ESS APPROVALS f Itv THET.htAL SEISMIC [ t /, 3 ~ ~o.., 4 =.. C l AOCnD PI9t $U990ETs t OhTA H3 TNT 3 por itsb3piCILl4TA0nf t crLrrro wLvt.rmsar e isswi cats era sinsas Gaoup 4 ~_a NARK *ttp ~ r*? e' -c.p. E t..tss'-%gP'go ,h rHis stitss GO APPUES ~ ~ g# e As Foltov.. jY 460 s . q.6, u*ns no. i tras no; s rz f f V /j\\ as snoww one. swe v I.EL.25f.'-r " MS b f ,,g,' Ess led as 15 STDPVALW MSV p.S ,A p $81)20-i + su i 61 Oti 0 's oca. onre o 7 h. a \\ ~ g. o sea. 9 I L T d 56 P .s4*..M 4 b '/ I' e REV. K NOTP, \\,Ms #' ')- 1 ADDE.D NOTE.AT G.E./BSGTil INttpM.E .d m (F.EF: F(.R-M-4419 F),;.2. **, ,ef s q N 4 N ,/ l U C REFERENp,, p,. gE-(g .cj M kl p,' d,, P{l D .7 Y / ~ -g M.Ol i 1 ~.i.P l I 0. 2.1^.; ~ ~ l g

  • e

-M '368 ' PIPING PLAN'~~.' p g g,p, 10 \\3, g EBB.lo41 REV.25, IAS. 450.. FAB..l W .f "o EBP404 Z REV.7, ; 4 ' cue, s-or.ata 3_,. .,g. hf 0DE _ DESCRIOl'!ON f. ~/ y. c . 4 .mi ~? NODE ~I

  • DESIGN.,7 '

+b,f,s,'#,R ....*10 D E IT.. b44 A.i.M UM .j... ~.-. (.... y J(

  • i*,,

i 4 (, ' - NOTE. 7-s / et'a'af,- M J N t,, ~' ' \\,. 7 t-

l. GP HANGERS, c,>EE m, - m. w -, S Dwa. N e

~ ~ ~ ~ 4: -a m.n.. } ~c g ' w - p a..s.a.cw\\ ...e. s ys

  • ~T;[

091 . a.r...,p : p... e ~. 4 m.n a., a..q. - ou.n o3 a. t W.P. RC.15N-l' .g -g yg,pgg, ygqg7j{;ygg9 4 jg-g Y +, O' [M ItCR0fAf$9 *W40$* M hi' M*V f>.IADIPC'fI' ~.- h- [ik / y ^ TJtgllU."'? ": ~~ = spy ~

  • i K % S*' 3"EY.f,$E-SAL 6 )'> W / /h a

f ~~ s V0li' UNIT.2 Sn 4$.- s;3_,, m..... H. g-ggyggy ggayg.;- pyn y-- f. me T Q-m peusuo,.,... s se sn-n.191s gh wrisavoi or.eers amo na + B W 4L 4 NN " " "5" "# l 9 LI5 TID I = ~ .'as . l=== a* l*a=== EE i Y oATA Rev oafs av REv OATE sv LEG:No

==as c.s. PtP N G i 4 SPR14G HANGER REGHTEL O RIG 4D HANGER ~ A 43p,3o, LIMERICK GENERATING STATION M1&2 33 g s,Q vrv,.

g. Guics o

5 rwy.aostrwiA stecTRic comerAny I n m % sN m en ISOMETRIC TUR51N1'. BLDG. UNIT'T.T }-) RESTRAINT ( U N I T.".1 " ' 7.:-/-- .s O MAaoeamiiii.e 1 MAIN STEAM' PIPING-(ude'd) ~ ~% O STasss o^rA ro'NT -- F 3031 'SK-M-tso3 $1 ,;r; E'+..- .I . Ai 1

u Sf*c Iblco.:biOh 9 60 31 - P-% t, 1 g.sd i 4 O l P*dlX C 4 q % /\\X v ~ 6 DETAf L *A" s t M_N 2cEBB-WF.,5K-M-1500 N' \\}mA %,,~'sh it c,o +Chs-,I*&g - 's4 T1 avaa-ro2, sx-+tso s"A APERTURS ,g e% why ; 9, CARD 2 e e> .b P 4 4 eg,,Io,"',. y, ,/ t ~ 2G'E88-lo), SK-H4501 !c

  • o,,

e .jk - ---l y a'k A r% r. d'so'l* % s Y9 s i 2, Y,3% s 5' EBB 104.W-M-1503 $L*(P DL.E. A.lO i P3A ) I I pellable'dB OATA REv OArt av aty oATE ,gpertore D"I gg uME

  • EBB -10 6

) Ff/n q)] e. MATERIAL SWL A SMt. fMot.sst ) 5 UNE THICKNESS ONI.750.338.432, i k 8 UNEO.0,0N) 14 18 6.625 tb #Nn "M,. hj, i uoon I n m ji, m ma i a TEMPF s pv i ] ~fh ur. mur.,Ni,w a: -t u e.co u,iL*'NIfM 5 .~

i g Un E
  • ~ o* *w a m h

i: 8 4.0B 14 o 3 g g _,3 i M-n.)

-s---__..__,.,._.7 t ' T{ l stress APPROVALS l l l REV THERMAL SEISMIC l a i 1 4 Rev. H Nort:. aca row awmerso e]ra **rm rea u t Y .g castro mer,rnen erunamra era sy enneme:r e n .,s,, .i,) c. r ' , w, h,,ts.n(.s-THis intss isoJAPPUES 1 g."O W-As rmov.u

  • s-p,,

J' tear n a ' As snown _ s &n s /

  • 6

/ .V 4 ,- nW ' e er / / nea sos .,2 k' ,,f' on cmo. ec arE Eas-los ee- 'N s 1

i c.,

.p y A v ic..w 1 . v c,. / ~~<--v. @* 0V

. r - -,%.

fg#'I!'f?T ,g. 's V',,69s# I

  • (

~ E ' '- - s' ryg.4. 'p.;:n. 3. u..j / . g - j.,.Qig r, ,x .{,Q. Ce _(ii t) ao.a.. ,,A ,h _ atFEREN,CE H ~ 0I ' %' 4 1P t s o '. ' 46 ~ go1 y k M - 152 8;. ; FinuG Puw - l ig8 O Y s o .gt d' A' M -368 !.1 'a I N g f,. 4 ESB lOfs

  • l REV. 8 FAB l$ O, -

h EBB -lO4-2 REV.S PAS 160 ,i .'.h{. EBS.101-1 ReV,1) f%B-150(i f sTE'Essac*I:.ot-nd y.[' .f. I 3 i 'sa

    • i.'-

' MODE CESCRIPTIONI'~tyE ~ D 9i i... er 4.' MODE I CESIGN, DL.G.A.ll DL.6. A.12 7 poog yg,, yg,ygg .,,g g,gg PSG P5G \\ P. EL160*-Ilis' 4%,gjRE.V.6EBa-106 PER FCR M 6710FitEV.I. F.V M g./ er ~ w 6 ACTATED niv-10915' Eis a UPWARDPEst NCD45 A %mi'ESPHC FLAG

  1. inf.

ACCED - a,..nr.<_ IMIT2 EBB-2C4 8S 5WTESEcto h ". ~ ~ O BysM**2752 free an-sysy+f 27fg a Wr REYlSED AS SH]WH BR L WA 'gT/sfy see m u uorr ,, s u w> s ey .fk *s,esm.eo r .,t so+-s h rf E 4cr l [- 9

1. I s T a o l A * ' " " 5 ""5 # * *

~ = >I DATA REV OATE SY REV DATE BY ' LEGEND

==a ~l-m lm M EBB -107 M % OM + sPRisc HANGER RECHTEL Skt. A5ME SA-Ictode B 5-Ricto HANcER SAN FRANCISCO .750 .*J 38 j

  • ANCW R UWlERICK GENERATING STATION 14 ia

~ A Mw "E -s cuioE PHILADELPHIA ELECTRIC COMPANY - t a m % SNU68ER ISOMETRIC TURBtME BLDG uulT*l ') N RESTRAINT j o wAnoER nuM8ER -- MAIN STEAM BYPASS PIPING e-e Q STRES3 DATA POINT f sosi sk -U-iso 4. H. g _._y , (_ g3 u - - - -- -. m

i s t- } q y e c.: $,'e c s,'c i y' ds @ 3 I-P% 4 M ~ g c 'z i;

  1. pendin c.

7 ( Q 9 ( ,9 ir si \\g s f , f' N / \\'ss-i .zcou-ics /\\ N.. i 3 s.& I,' x6'f vA.x.B.o\\y

3. uuyg SECTION A-A gg tg.

4; CC E e%Y '.d a I $:B{43 '

  • h'.Siqt.

Y # 1 t 9 A.. M,, e, ) 3,;\\,p" E [,s> .1 .'h?.ys ' l g$ R dim m,. m -: c ~ TI k 20 4t

  1. -p%v[$g 4

g q% &) e u m APERTURE 9 y CARD %.{'.sg . W ,1 yQ s.-j NOTC S: ScH. Ir.o TEG is To sE counrt:g. e

  1. 'oo 4

Algo Available 0.n ro m Tc,..sc,..,,, c.,i. 3u, sc,.cceo G .so Aperture Card ["g'*'.ricce. H il VIDIATE5 IT.I CtfAMNCE REQUIREh8ENT01, ouL SIDE OF THE WELD I ( AS REPORTED 04 FCR M64865F. t DATA REV DATE 8Y REV DATE I

  • UNE 8en.

CLA-ICS l o [g i f nsATEReat. 5ut Amt M-333Gr.* A Xf/n //f 5 umE nescnntss tim 1.812. A fr//g Ap,7 l 4 g, UNEO.D.(INI 24000 A !I9f# .ft.f; I j asoot I n m (;,. h. ess... ,E gm )g840 814 0 3 2 6 -/G 1 - e n.co y,...ioo,1 '" '*" L -e m: Re v. I ' ~ "~~

sizamt _.. q... _. _, STT.ESS APPROVALS \\ ~2 DX ~A.0 % l'A Td T. REV THERMAL SEISMIC e'*

  • VA.Y. G.03 c

10 7 v: 1 ., f rg* FEv. H NOTEi id

g46, e-mm xs. navie.an As sour 4 r tz-e v A.LB,og 77.sEnaWJ TD MAiCW FAs is

, 'e-.', t ecoro es4Nera smsots peR MARGER QROUP MARK.0P. OttlilD VALVE DATA / PRESS /1END DATA. jg MPED VALVE N9 IF0f0A PER PKID M.41 MY 12. g N *. 3,e -EL ~ ADCID REF FCR M14815F S NOTE I IwccMP. wcP. 07 ,' *Q ' b@* 4*-Bk' Noit 3 MO. 6621 REV. I DELETED WOTE l. APPEP .HQ x 1, -tripr+ S x l,. ho L ' , d' f e 7 - h *t vA.w.o.ol\\p h, t x fi o y ")3,,'. a VA.1.Wos soo [4 \\ I, o i N Ilo5 e-s n N / i? .J } REFERENCE STRESS C ALC.ft! l 01 3e b k.,, M-4I PI'U ,.g h g*/ 0 3 g. g ',g.c' 7 M-234 PIPING PLAN + / ' fj ,,jj' (d" . y 8 M-ass a = M.. /^g9 8 'v A pt A.107-1 FAB.150 R E V. 21.'. 3 D <.,;g O 96 = OLA-tos.: paa. la o Rev. l: s p) 83 gi g/ Y l 'M FCR M l4615 a ,i Mj[i}y,P., I "o e oE5c" * " Ad [iy "4,. ^ !';{ J mt i MOD E L-NORMAL. CONDITIONS g/ l : 38 ( gg'jggg ' M. .1 ( s MODE T-MAXIMUM CONOmoMS / ,, g ' I ',., 2. MODE R @ }l 'L' t

  • 5 'y

/ Jl &ym m 41 g in,/ 0 I C'*K.PA _,h -p 3. . _ s% wn u ,/ .R ) V-f 5 A WM MM WWh! Y W W/ ni g.o t-rc= nu y w,, n x A s N I. Q2 8. 'Q*N. .,9l 2 Wr in"frWUd,T e, t%8 Ilful [N % d H a 3 E iES-d N & @ rI SAL AD4-l# M2 tbP' O N 9 ~ c u iw,%= m-acca

  • w w B 's!wM76 8-WdR."'"8 9 JO fA Pr %4 l

9-LI5TED <l3 A % M '** Wi% M O JO N W % I'h a,;== 'm. gg l eme m l u es J. Q, gg DATA REV OATE SY REV DATE SY LEGEND ' soma - DLA-lO'T 4 SPRihc HANcER REGHTEL / ~ SAN FRANCISCO sut afat n.m o, a A y,,rf, p7

g. n,ciog4ucgn oM I.031

.688 H

  • ANCHOR UMERICK GENERATING STATION

]h", 24000 20000 12.750 A Wrff,92 fr cuioe r n m lessNuuER ISOMETRIC-RE ACTOR BUILDING (DRWELL) N RESTRAINT RQWR-Wdl 1 c O NaNcER NuueER O sTREssoArA,omT h sost SK-M-15 52, k ~ e w ci/ g -

J 1 I*f SyeM$icchidn q,5tig,yn. op. $p31-r-36Y id l N N 8( my hper,dit C 1 [.6 9/Nx i i 'l i .s' .t j (TY $ _2 , v,; (\\\\\\ 'h i ~ fgt. 4 p ~ +9

  • 1

/ l Q$ ,p.99' 1 v ,.,, r f t O i 4' 4 f23.5* 5 af l i (' 2%r i' # ; + d' M 'n 9 Q ) llf S. ? e# 2 TI A ' * *x 's V j. i APERTURE +"7.i 's es ' 1 ':c CARD M NQ/;h k ,{ j cA f %ff9,,. A y E

2,/

, p., J xQ,.R. %f' i ,1 . - x' SQ.+. ~ N s + / 3., / / / s ~ 39o Availabic On p, v P I.!hi , i\\ - - 4'-g>'r Aperture Card g, s y o l 3.3 %_ i gt'-3 4 3 y. ~ e ' s 1 i OATA REV OATE SY REV OATE a5 UNE No. OLA-toro a! MATERIAL SML 4tM JA 33) de 4 A Mf74 ,4+.- b UNE THICKNESS (IN) 1.8t ?. A #r4e pp1 l .2, UN EO.O. (IN) ZA.Q)O h Yth? }</; MODE I E N hI PRESS. PSIG ) 'f TEMP F ~ f g E,. w E,,.,,,,- ,e j ri '" "Jit_,Nm. I 17ev,f

  • 5 e

i i

r o ST"ESS APPfl0VALS 4 IEV THERMAL MISMIC e iElc 'h% b Dl. }'l p( \\' l -g 3 +: pr a+ h g., 1 Ny 4, REV G NOTE.* 'M' l N - s

  • ,4 Accco pipe euppoRTS 4 DATA AcnNTS Pon 43 b%

>+ g AECONQUATION. DELETED PESS./TEMR d, VALVE f .p g CtTA FER STM55 >%RK -UD. geS g('t' sucom uca sott, Aeoen vAuve. ut, L .OET'A' PANGER LOCAft64$ Cm.Y 4 C C N R E V_.Q___. ~ yd,,9 s c pf*$f. $,O CALC. i y 3 7 NO t-i t-o t. a w a . 8;., ** '[' pd 'I T' .n S $1. REPERENcE ~%, / 'l se[' ^ [ j ,g g_4; pgio c.: 8#' kg [YJ [;23l FIFING PLAN - G ' (; h0 h9,. C-DL A -108 -1 FAB 150 REV,tr7 },/

  • 9,- ! '

s DLA - 106 - ) FAB 100 RE/10 e l>o > ~- g y 3g STRES S CALCY 02 l ' /M f MooE DEscmprioN f g1 y MODE I-FMMAL CONDMONS 'e+ r 4, fM"" McDC 1-max 1Muu CONDITIONS }* ' g%. g-s'

T

/ s ys C y. s T 7 j, $2 ? 8 4 0 814 0 3 2 '6 ~/7. + y' e% sw. Rel. e tot 6 P:s pA w jg'@ x W, F 8k FEV. FWy.A M 19174F A (f 3L f

  • f;;"

g.d. ' q' D E.a

  • Limer.Rcq-sesF 6 SP EJS eW /, **

l / 6' Y + D '9M 6TMil8f84fr3A SALAcc. r# 4;IfW 9S % DET B 3 c Mymistows n swm Acc er/ e W,id eV uwcee toca riou s out y B / i E M O '. W '*d84 J C. M 4 % A'W e l 9-LI5YED l ^ * *h*E*"* JU N l ~ = e. e Y OATA REV OATE 8Y REV OATE SY LEGEND ema - l esme se l sense J.O. = OLA-lOS

4. SPRING HANGER 8ECHTEL i

5*. Af#E $A-331 (,r.6 A Mffe jrf,J 4-RIGIC HANGER f l.218 1031 487 G

  • ANOOR l

UNRS 1 & 2 ?4 000 20.000 11750 A //fre . 14,

i. Guios PHILACELPHiA ELECTRIC COMPANY N ** * *"

}-) RESTRAINT IscMETRIC-REACTOR BUILOttlG (D FEEDWATER - UNIT *l

  • 'm

] 8031 SK-M-1553 Gyl 1cW (t/c) k.

y .______,~m i k i I 9g e c.' Slcch s'cn l ) 6031-P 36Y N gg 1 i 1 4 af g gend11.c_, l 95 i FNx 44 p# 2 g t lL s / 'C w _? \\/s> t m .,'ke l

  • 4, 'E t

6 4,'o e. 4 y s l $I lO 0 j 4,0[#310 ' / jf 3 '.t ej, f- + ,s 'I 4 d ,, g g e L-4 '. +v-t 91 >*g o6) I 6, Y 4 pf. od

    • D 6%

A6 c0 g ,_ ~- SV Alao Availabic On q,c tur. Cara pote :

1. FIELD fD BUILD UP PWE ON 901h Sip 65 0F valve uv-W105 To roAmrAN rn:W. ytAu. Tuicxtess os: o.Sc,s ow Des sion or 0 544*od ses sice.

DATA REV OATE 8Y REV OATE o" UNE No. 088-103 { Nf MATERIAL 54 MME JA*fo<,5. a A J/4 jsrj 'f ur:E THICKNESS (IN) I 0lE l.2.j 9 A Nf/79 ggf/ /f'/p agz. a, UNEO.D. (IN) [,4000 \\[2000 A f ! MODE I E N h PRESS. PSIG

== 3 i TEMP F

  • h a EXP. COEFF. tN/100FT j

N = %,,, Q ' e ~~ 55 Moo.or ELAs E ess V llev,) b.

7...-. .f,[g$ [,, gh( p # h 57:555 = aov^t8 EV THET. MAL SEISMIC [ h goF l / 'to2 ,, if ' l Vp s a-h 'c-Yg ' g,t,' 3 0[ ~ REV. L NOTE: 4M A 3 ADDED PIPE SUPPORTS ( DATA POINTS FOR REccuCILIATioM. 5g, DELETED VALVE v: PRE SS / TEMP 'Ugmf8 l CATA PER STRESS CROUP MARM-UP. N' t REvls b op P 5ET PIPE,CONFIGURA-I' -.(pe A ""3 '5 ITXs"J."I'dD.6% j 05 A c c,Y gN (was 4 g8 P00 g .s1 g mCoM KAM A7, h' g'I REv, M NOTE. I 3, REVIS EO DATA PCNT B-58 (Wa4 38) 'W-M N(, 95/8' Dew (wa s ;) pER FAB 1So p Adoan c ara, PotuT SoA 4, Le wa waj /' k *./ ADCED 15#-HALF c.rwr FER FAS 150. r 3 ~ \\, ~ 6 3,,. e 9 y4 $.f*0 I % / 9 r 'W st I REFERENCE ? t i-41 P410 n g 9 M-2% PIPING PL AN o' M -g,34 = a r 6 -H-IS9 a D o 6 DBD.to3.j REV 9 FA&. Iso f 9 [ ,) D6S-to b-i RsV 14 FAB. Iso. 5-t/ E. C. 0 3 s f calc ut pi-es -51 39 - M000 DESCRIPTION. + MODEl-NORMAL CONDITIONS - ' ~ ( MODEII-MAXINUM C.ONDITIONS ~~ t MODER ~~ TI 8408140326 -/8 APERTURE H" MUM J8 SS M ,H CARD m cza mvers ra es L % SEs REv. L NorE. SD 9T., (pr W(, W g e inceap s:ca Miso 66 Ss y5 .15 s pk. g/r J.u..- n. -. mo eta w w<m L 9.L: s r a o l A t== mmsu* m W n' T-e W m ) DATA REV OATE SY REV OATE SY LEGENO ""8 l """"" l8"""J0. EE l 080-103 + WRING HANGER BECHTEL SML ASTM A406 Gr S B

  • 85ht /4.2 5 Riato HANGER a

%5h4 A:r,2 A* ANCHOR LIMERICK GENERATING STATION l I.81.1 I 14.000 B 'r'% aa2 is ouioE UNITS 1 & 2 I n m }etsnuesER N RESTRAINT O ***cta auwe<R FEEDWATER UNIT *l T~ l O StaE55 o^r^'o'ar 'M 5031 SK-M-1554 Fw swTwd

{ I,_ l i i Gyecl$lca t'oh go31-P 'Mo'l ~ )' 1 N l VA.E.C.o;t. r 1 p;7er>& c FV in t' ? i 4 i s i ^ t 1 d'C 10 n0 s,$ 1" ,103 N 4 ,. % g G O,g. 4 ' 'gh. ? / ivallable On i ,^ $ i riure Card go 0 .a' /# O6 gl. 66ls6,p c0 y 56 oATA nty oars av nev oars e5 UNE No. DBB-lO4 h

  1. /#M gy MATERIAL SML AsME SA-106 07. B A

E UNE THICKNESS (IN) I.0 \\ 2, l.2.19 A-9/fM A p.2 L %%9 gy UNEo o.(lN1 24 000 !(s000 l MooE _I _ A- -g- ~ C - 17 gg c =

1..,

i a l ]: 1 ,5 ax,.Cour. Nnm /.. =. 5 EXP. CoEFg. .o u $g g, l "5 uoo.or stas. e Ps: I,

l ..~. _ l STEESS APPROVALS LEV THER3t.L SEISMIC y ,g0 9A.K.d.OI pF @d M F NO7!'.: 9 l l5 3 ~ AcceD PM SomNan f. DATA Poiens pose, 6 C, meceweium.rion, om eren msss/TwR 4 \\ g 0gD ' 5 vu.ve casa w r.rnass escuP WAmaWP. l2 ) '" @ # 'g ADDED Pt-U6 5 / I' couu.tPER M{, A p FAB rso., INcoev. Pce Pf ir.2os P. ,N st 'P { cf \\,. [.' d 1 Al 8 t;;" o3 a, 4 'C' is i 4 h 96V 00 f .}_. ,o Q Op 4*(p 1,. ,s s .. el -cf g-e.- ..n & 6 *,- w _ p [,j,9,p, D .,.,,5l . -f, .>4 W i /.r.: s l \\ i. * - 4, l g e n% i . Og ("h ~ I .'( REFERENCE - g-4,6 M-41 P{lD \\gf'- g 44 M-22G, PIPING PLAN t 3 s I M-2.34 u VO + .+

4 g

M-lB9 '8 F.. t. !) bp \\ CM.C ** Pl-IS-51 Qt oso-io4-1 rA.s iso nsy 9 W e DBS-to4-1 t Ae. iso say it. N d' ~ McDC DESCRIPTic,ht - ~ g b MODEI--NORMAC ccMDITION" ~---'-~ s -a .h. I MODE II-MA XINUM ITIO M S " ~ '. Z.' q / I '~ p,1 MODElII l p g IN gk ,1gi Fl'I ~ c0 l se APERTURE 8408140326-/9 CARD F 4eeSex F NoTu Ar8?ry P/ E %N n.J.,k BW ik N / Nai O Lg c.H f.N AS 40T50 M. S/(, W8A M h eP8 f e c, W4 asvoto as suomas EO es At8/ #% 8 % '.T. nst"v%iN Y'"" J4. 18 tY % 9f I 9 Lisie o l A %,ssuto ma smss n. < Jo \\g rY % TW & = ,,:g - l==,= l=== J.O. M l0Y DATA REV OATE SY REV OATE BY LEGEND e=a Dso -104 + sPaincHAscEn BECHTEL WNEM SNL ASTM A.106 Ge & B Yl5h5,4p,7 E nic oHAscEn B WhS 4#1

  • AncHon UMEltlCK GENERATING STATION

_f.812 [I B 9%//g fr. cumE r.4.000 .I - --u - tII 10$,SNL88ER ,,,, ISOMETRIC - REACTOR'BUILO!NG ) H nEsTnAINT / O HAacEa muusEn . FEEOwkTEN~_~tJNIT

  • l l_,

'/ O STRESS OATA POtNT 8031 SK-M-1555 4.. j -L F # S T M. 7 0.0 2.1..1 / d ) .A

3 9 i ~ Sye c. )S:c chi 01, l i V,$ 7 G D 3 I - P'- % 'I VA.L E.02 47 N. + f 8f*1 / 5, f h

  1. </

"A > '<$ Y ?/9 A. I hp e / go2(Qcd i g"T1-y'O } 3 t. ) , 4, - ) q #' ! p in Y '$.t M s m\\ N > 1 N g. v \\ N b l.. ~T h i li g. ' ' 44 {a et Also Avatilable On - g Nj g Ajmrlure Cafd f - i 7)} jf$$p &kaXy Of o/ p. +1f i. s s-s,q p.' y f (,r hh / O L-l\\ / dp-5$ v 4 , s r M k ~ g is !,g., b#f % e ,g. 4 TI = s' APERTURE 5 to I N pc' 1 U UZ 'sh CARD 4' .a DATA REV OATE BY REV OATE I gD LINE No. S88-188 E 7 81-71 (M. t s! MATERIAL SML. ASMG SA-808,eC8 6 2 3777 8/[ $ Lf NE THICKNESS (IN) . CSS .5m E 't. i? ?- //f g, LIN EO.D. (INI 1f.750 2770 E 207) M[ y g MODE I E M 52 PR ESS. PSIG [ C-f@ j 3" TEue r Ex,. w o,.,,,,,oon n -. - a.,_ $ Moo. OF ELAS. E PSI t t - 9

ym m. sTT.Es5 APPROVALS i g nEv THE..uxL sErsuic \\ ,ff3 - Y {r'%(. p. 3 ,/ Nore: o so s \\ } m, m,. sassons sn. s\\ R .u t o g&'. ~Pfv.J H0Tf: t F J [ sf A >/ Qsi',s, ./.: ADDED NORTH ARROW >o rr 4 3 f COLUMN REF. gav.E 149. Acoso com T s Y *.g DN. g4 R,* ps gq]go W.R E.I.EVA rtout A% NOTED. L

  • ~' a 3

ks-3 REV N NOTE: '.j p'* 3KMJ5564 WAS Wl.GS6e A ,N nwto vnvf MA PRf-Ql TEM: DATA,' '~ \\ Y' p f Q' t$ f A DATA POINTS FOR RECONC/UATION. yd.*<. f ~ g ~ 8 "q'M + VA.Y. E.01 r, n,r,

  • l

~~ e-Q {*,61.oY,h ' """*' STRESS CMC. N2 PI-10-72. lh' h N ,O (* M-99 P'410 .,' gl M-221 P91Ne itAM g @y M-120 l y,b' M. f.7") e/ d L56.l#84I LEEUTid ' v F%Ib,. lSO. ;,',,, e J, N E6Slad-fsRES20 s / WP pt",19CitlWON '/d o# la / uops I-womm. sysred now orowiwe r mru.A / k I CONPIT10NS. ~, MOPS E.- MAf tMUM P011GN d#HPITloNS1 uoos n--azur wsTm a er!ve.3 hg, eh[p r,': ' concnrnons. r;- .s v 8408140326 1,d 15568 P & N2"$.W &W WNW f l f'f N ulVSEE red M ACTE.. *L' & Wr 23 % N it g, u

  • *, atVPER P450145$

SRT d E / N 'o Qp see net.McTu tp g JN / % o VA.L E.c3 pggy,gy, pv g w / "y 75A WW FCR+t-40-34F JOR tsJ?.'hiIn H25

  1. x a n sAs u / n,o h /

N w % gra.e;w.47 7 er v4. q 7f 5 %WdWiW'M J!R At- & / r% J t= An SEf Fru.vors snu s.o. Y .<' "4 s udi'74 :,a=';p t.n. w, t M aw -. i -~. ,2 OATA REV DATE 8v REV OATE 8Y LEGEND = =a lm. l Ltaeaeo lll= e saaiscHAscEn EECHTEL

  1. - RIGiO HANGER SAN FRANCISCO er Amer,on UMERICK GENERATING STATION

' cuioE UNES 1 & 2 ,,,aonewiA ELEcTnic courany D' r a m 1*B snuseta }-) REsinAimT ISOMETRIC - Rt'ACTalf Bult DINQ k nien eRessues cmem mJecTioN O HANGER NUuSER UNIT l g O staEssoatAcoiar ~ ~ - ' ' i 8031 9(-M - IN A P ) (o/c) HPct STEAM. / i

.( y o u 3 9precl5 c.cklCl> } g.h f cj O'3 1 # - 3 (o 'l i e ' ; r. Fx. a . J ~ m* % . N s.* / - l).yr,0 n, c c., &*.G / 0, 3 4 s' 'x- 't e.%yf -'. s t ,/ G.,,. '.l

.3 s

/ , y4,. e i /. - G. '.s ,q# .c. Y s.e, y4. - / s 5,.y'.jhs'?hk.' y s tM )', '42 ,%.l'/p 3 4 i /gNL Qb <f sC 2, AC.,, u w. sw. og en s Mw Available On 0N Bj*0 Aperture Card ( 4 e .y M't..D M MILM gg-(f A,,1-p9 t-gu . s,s e Q- .o 'ib>J ---%,. m M Q, $gr$R.. 4 =.- s p.3 e.J\\ Uf> s.9% %,Qy. nm ,u t s i 9 g,. d. 9.,,. c, e t A.s ,: -tj g,4 .s. Lv N. A, <.. n p's.,qir.'cy,j.%p s-v '. qp/, ry j ~,4 - 'n 4" ... e i .,.w' +- >e.i APERTURE iF / 3'W'$]1M A-CARD % t E 02 i dN.h#.gl 3 l a * 3 8/ / OATA REV OATE SY REV OATE o5 L.NE No. S* $ -IOS E J. g} 17 / /.[.' z~ { P 4TERIAL

  • Yt. 4%1G $A l'$fsf' 5 6

2g /h/ 5 unt turcnntss eins _.G . * :4 E 7.n y r) ? LINEO D.11%) og f r.o .o 7e.0 p, 7.g.7y /*/_[ 4, '.*00 E T U HI ndj PRE *SP9G g ww .,,, l TEI*P 5 4 g a OP. COFFF. IN 100FT . 'y E (P. COEF F a3 nest-Sts I l ~~' '( 4800.VF ELAS fP'.I NY6 [ i n g

r-- g-3 g , W, w-sit's.s 4.wovs.ts. = 4Ev rwEnvAt sEisuic j l g f'f ~ '1 / ~ EEA - ,. F[ P[ NOTE.' v ),,.l' ^ 0 THis cws. ?uF'El?9E. PES Sep 3G2 er / 2 '309 l

i1I p
  • V p '9 ff!/.."Ho?f; q

o lI S# l ADOED NORTH ARRO@c,OL,russ isc, y.- C UMN REF. 4 TE-i4s. eso co i; .r :e .d,,,s,,..,..f;l3.~'Q. MV. W.R IE.LE.vync W. As p.cyco* "j ~~~7.. ,9 pt _ ] l, O'^* 8;t k! ssus 4:3.Q* g., -( f,' AccED dncen awa:< s f:srA mwis EtvH NOTG" g -,) t , k. d ~$ r ' ' peg HANGen MAO;-urs. 6 N _,4 ~ Q '.,.9 y.p.tS$G e r/A5 SK*M */SS G ~ 'V,. l p'- e, ' 4,', v2-i -6 ) I,is g i*g g i e.goaoco voviod c5 $50 f T s coa.1sv.ouw.cos ute.sfpi e t.iewssc: - nEFEnENcf r '.jg ,I.jeyp e

u. ~ s s+.

M.,, n l2 p., / g'6 .~ u :21 rwma r.,m N

l..I rE M'E2' P

~ g ty) ' f.f' M' 21*) !.s (v g 9, Los 108 1 EE'l 14 Fra l".,0. ) g. t voce ascenwN g,. P,'.* r4 ,,f,g - @i MoG'8 I - No" MAL SYSTEM WN drwAT54cq g. s p.- cmc'sT sons. F MOPS U. MAdlMLIM P%GN C'4NPITidN4-t s MdGS R AcWENT 7F.,TCM.2 t'F*AfiWCr

  • g, (i n)b gf8 cWicm tor.G.-

f i STRESS CA LC. 8' pg 7,4-51 = f.,g. / R.X.E.ol 8 4 0 814 0 3 2 6 $'2 / n r 5t* N **'!., SEE REY.N Eq-M F $$ e. j u % Pa m n, s.<, n psy]. /- m-

A rt~~.p.c A.

4 ;.;it ece prry.:f:, t c,)crg &,'/ / r,i., b '[Da*Me$. PV V, J.* 'V. \\ ~ < CCN REV o '

  1. ""*N
  2. '/'S A
.t

%e i:cta sco ato .~ peuw.nn n uw / p CALC. ? e 7W Ti :.,4 s 9.cu x,F.GP V NO P1-u5i 6. n ..a t= x s o. e v.r i su..r.a. ( e_ %i;;-W2 s xt. ut.3 ;n wa

.- ;;r.-.

l =****

  • l.*.** L L* PM* !."E 9

OATA REv oart av REV OATE BY LEGE'm ~ i

o. sPamo wascEa BECHTEL 5 nacio waracts SAN FRANCISCO i

LIMERICK GENERATING STATION .,cg n UNITS 1 & 2 l

3. cuioE PHILADELPHs A ELECTRIC COnePAssy

% SNt199ER g g gg ISdMETR'IC - F.T.ACT"4M' SulLPit c g,gg7u,sf HiGH Pics 9tFE CMMiT INJEC[8eN. t unit ! l -. - t 8031 W-M' 3N N '(o[c) HPcl STEA ' = ~. ~.-

' }, W r S dr e* HEC.c~bo'Oh & Q' } f A Y = uP \\ dinl-P-3 6 LI w I s.- N u' E I kyendlyc_ i w e. a w t &3m SE I m,,.,t.,,7 N ~ ot. s.o.o i >87 al, ;6 VA.A.D.Oi 4 r" i:: 20 #IS d#MI 3 ODE 1 b 2'10 % rminN t O'$ WP.EL, 27I' fo'I " E s-WREL.27l$ ? W.P. EL. 28 j7 J 't ; l5*5y t W.P.EL 250' tVg") 0 3 w\\ / e r 0%vo5 b (J i -1 l'pcA 165(FAR sce) N e. + k - lPL4TF EL.253LO' M,0 1

  • i rpCA lfe4 N

PPCA lGalFAR SPE) b I J., SECTION A-A DMooa

  • o '

31h / < qtyq". (/. Y / .EL260'-28 A- / lo" DBA. lor, F. Y* GR ELLS %*oem + earr y ,r,a e, d;j. c. ~.n-w m, m -y 7 ^w~ s

w. %

n

  1. g m

wcar v Also Avaitatie On 1&DBA 10f*N-d slauwoTercou. '# g 'i verture Card ___gy.njbRY .ss56 4 Note) \\ d L.2+4-89/ SECT O-D esva t "**D SECTION B-B i TI o^7^ aEv oars av aEv oats "S^~' TM 4 "ATERIAL Eg 3R A9tE SA-tdGGr.& 7/% g M UNE THICKNES5 f tN). 774 p a UN EO.D. (W) pyg fa -E n { gE PRESSs PStG y 3 TEMPF h EXP. COEFF. IN/tOOFT ~ 8408140326-Q. /.$ wi ExP.CoEFv. gg ~' '-'a-M00.CF El.AS. E PSI n f-eu, j n 1 f

I 4 ga g I sT:Ess ArenovAt.s f.p

Ev THerwAL sErsselc u n ")

/ 1 / R E V. J N o T a 2 C-C 209 g ./ REORIENTED SU/E. WOI 1 Pelt l / M-7840F. NCORf.FCA W-F FEY.. s/ - i esv. H Norst , aucro,.- n 2 G _ REVl9ED t.tME MUMEHHC FWOM IC" ,,/,,-;v urn. DLA-ic9 To lo* dea-lo(e Pse oc.u

  • n.-

o.' 1 pa to M ee stav. 9. itsvnse c,e g ',*\\

m. cow w w* w e g aso et.m oe

. PMt. cmcrWe WeeuGr rr M4D stateMiGO a a 4.' . a. w.ummremwe e 1M, ', '/ -M

  • , g.M?

y., A.V. D.03 oF class otA.Fisto wei. pews 70 er iN g K.compes NTH rmm mss Da ~' ,,'f /g y \\ 400 REV. L NOTE

  • f
  • t '-r u

\\ A00EDPIPE' SurPORTS 4 DATA POINTS Post t / q RrocNetuArioN.Ot!Lt.rIO Ptets/trMe DATA: N " Ano valve rautArso8 DArA.PGA SfRST,5 l* /.-j/l HIS 4 GRoGP M wK-JR A99EO M.EF Fct-m44,>4tF. v fl // lcw 1 ~ ,. -l/ r \\ on voc2 .~ l 'j 1 i (/ f REFERENCE CAu* l-O t-OS ' i v.. L M-55 P4 ID l .g 8 M-2t 3 PIPINO PLAN *. i 4 4.;u,' - y+ / M - 225 a l / y- / g / N*, t'4,J M-226 a / l DBA-10fo-1 FML ISO REV. El (a /'. J h / rrdg DBA lore-2

  • II a

'REF, FcR. Ml449t r': s dtn ,t /\\ ~> f 4l / ,q ~ /. 4 (gpc- --f,yty l 4 +, Em 3,. 7 _ e ~ f MODE DESCRIPTIOM l .-t l 's,* f -^ MODE I-NORMAL NON-OPERATING CON ' ,s. p DITIONS (REACTOR AT NORMAL PRESSURE) N 4 * /. * *. i MODE IT-MAxlNUM DESIGN CONDITIONS ' i I" **,

  1. 'd

. f[s ' MODElE-MAXIMUM OPERATING CONDITIOMS (REACTOR AT MAXIMUM PRESSURET - l g gi f> (REACTOR. AT ACCIDENT CONDSTIONS) g

t,

,,M [,j, 3; d@Stt REV. J NOTt' SRF EM/W l / y H A GM esv. H uorv oTo Ss + / 'k a l. /,%g j 4 FM REROUTED uur. Aac #M 'M / m Qa, + um > u un a wie. w. a.r Tre onse) 5bsas,aw== ~%. PL'AN a nm szyun e e. av. u, saw w u 2. T C. 3 e.wwu no n= A,A ETRqs MD PtAT ms - LI srs ervL nors wsw EE V g g!,,c,,,,, %,,,, y, _,,,, j .g ^ I l 9-LI5TED l [d,

==.'E a

p DATA } REV DATE SY REV DATE SY LEGEND ,ema - l emme es l en.--Sneia Ez EE + senisa wAscEn BECHTEL I O RIGIO NANGER i .g.,uego, LIMERICK GENERATING STATION i f.- cutoE S1&2 PHILADELPHIA ELECTRIC CORIPANY E I n m' FOSsnuaaEn l-J nEstnAmT PLAN & SECTIONS-REAC. TOR BLOG O HAncEa aumeEa ""*"**7N"" I 'l l l O siaEss o^rA comT y . 3i sx-s-is32, L i O/c) sFtt sT=x

i i j,

ht < :ii f ji.

"l 1 4 A f 0 ff 3 W 6 e 1 i A" n l d F l ' C X.' I c g Cg %b Y } r l A R' 1r C y O $a D J R {h D c l ? A ?. l, l lj I !f OO2 5 o 5t ga O < s. wb - s ZO 5?l t :, I I s e N $jc "fs f 5 D = E E T P L L M L = IN I A I 0 x X E R N N 0 .P .P wE S 0 E E T E E o oO e w E 0 T IR N cC S F E E S .0 IH o P A -N A .F G ( C L g.r E F I I K L N C I N GI S tN E A f Y ^ S E P 0 ( C G .% 8Q -(h E S L / 1 E I F i IN . S 8 0 g S %x a ) T r' K C 1 G .if t r + 3' M Ml 9 l 7 5 7 - 1G 9 L 0 6 A G go8 h G 0 k$ ( 4'. g E C. D - G ~ of N. A n o T l~ S A S A [ O RIyG ' f3 I ( s 10 l l ,$ j ( gg r m f. G t E pw( B i. e R AA A_ ~ V 44 e 5 g ,/ j y 14 D fhp 4 A cg f ghh T E Y ggg ~ O D .~ .L \\ B \\% Y j J 3.t "Y W, 6 7 6 3 % R EV e 0 oV ,.c / 7 / O A l' 1 T 7 E O a .L } ) 4 ]; ,g-t s ) l l jil l l l l

g- ..._. -. ~.... ..,.,..f,...,.-.

c. -

STIESS APPROVALS e REV THERMAL SEISM C \\ (B[e rL fM f[ \\ Q [/ REv.H Ucrt: \\ t REV.COMT.150 FROM GCC-104TO 680-116. h . j.p. J2E\\/.L NOTE: ['N E.E.W.Ef? DMENTi cNA, 7 M.t.em. [ F[, o WiTd FA6.19 ill. 6,R.O I P g) RE'/.M. MOT E. 330 ,e REY.PER FCR M-Il840F. <3' Aid 1 /, .>-.M Rev N.Nore : '? ADDCD PLPE SUFFORTS AMO DATA PCINTS 'f ff4* F09. KetoMOLIAftor4. DELPJdo @(SS 4 W. J[ir 8 / 9Afh %#. STR60 QROUP MAggr uf. IC6vtS60 l / g { #y.fP 4 c' as tuoicuca Aooep gir.rcig sie4e47 l Eo4 w $7 Y

  • . */

QN[* NGW ot.s.mo2 ... p a'-n m' t-s'.mDto awiss14issu k,.. 335 Fra F4 IP M-41 RE.V.6- /J F ,4 AEV G NOTC h l .i

  • e r

5 g p I ?.' d REW49 DIM. 3' t.deDG 2'll'R!Ir. FIELD REQUEST. g4 ( 'd REFERENCE as M-41 P 41D - L 1) I ) M 213 PlPING PLAN p9 R M '125 PIPING PLAN ^r 4 M-17G PIPING PLAtj '8 G Ecg)'o I-17. RE.V 'l Sj FABl. Itoo, hy, - ,p, 'g~ ,, w g , ' t.. C'484 F-. 82 ff-dn 2sdA*, # 1/ DL.Z, E.0 3 c.Atc..r4o t-o1-O( 5 g6- ) 5'5 N I 1, r*'. .'\\ TAODE~DEGCRIPTIOW i k.= f

's MCDE I-NOF. MAL RELIEF VALVE h

OPERATloM 4' k h Dt.s.R.of, s f' %%,,,\\-2 37z ol Y R o6 - 8408140326-M I g 366 / Q NM SEE REV.N NOTE I[S4 @ er %$ L \\ N 11.F4 SEE REVH NOTE FY flE3 'Ke / % %54.06 \\ M SEE REVt4NorE py jyP EL / ~-)ff*. ~ 3go 'n L y sea tsv.t.4cm e Ws,.W / G, K h h. hf h z, /- T 3 61 e '@ #;.'J/ W.Mf," sw =6 wi / B UW.:t%'U.*, fit *P M(.A g p g pV l 9LI5TED l4 W* L M f7f " N E& \\\\ Aff "

  1. 42 m-

.= R EV l DATESY REV DATE 8Y LEGEND "8 W 8ME l '** l== fa9 MT41 M CY DATA

e. SPRiso HAucER BECHTEL
4. RIGID MANGER
  • Anchor UMERICK OENERATING STATION UNITS 1 & 2 s-cutoE PHILACELMelA ELECTRIC COMPANY U '"""' "

IGOMETF2lC-l2.EACTol2.. BLDG-H "5""^'"' MAIN GTEAM UNIT l#if '- O wAasER sum ER O rrRiSSoATA,o,Nr so31 6pM-li94 N. ~ tass.v o

t e l i r ) _n..:7.;.. '--*T.rpungary:yj'yyr.yq:f.ri :.::??d l '.97 yn r =.. h,.. <..... %g b.+ .,a.,...,..:. n.s..u.w m ,._.,.. w...c..q.w n i' #,# S-F e.' Cf %':7.W - C..;. 4 ,,. A -d ,, w,,,_,-w^v. f m., _.2. @ m- , c. 7 .,w. ..a e e,. e. n_.._..._... .?;.....s.,...,.m.. .s,. }.' 's .s .'%..^4 fBA.f g [ r ,,,.j,, V..

  • *,j r,. y".

.e a 4.24. *, a..

  • g*
  • e

...r.-.?,,...t.....,.J. .a A 1L'a#$ e 6 e. r

  • t, ag t=

...,.i.t , m.v.- e .=9,. mp.,. -.m. c. e.., a. e

6. - * ~t.r y.....

,.,:r,.~p p.. nyr... - ,.w.v. p..,.... y y ,xa:.,w . u. ;. .s .w.a r.. .y. c ,s... ' ;,._.e ' ., J... .a .a

c..,.

~f.,,-..,.-*,,,..;..... + n. 4'W".Wnif.1-2.-:& K'e? s e

y.q,.
  • t.k. g

..-----.g ~w y s %s ad. e:;.*;* s:9. 8 A., t{. 'Lua t..,: '. V..e.4__ : 5 ^ s ,g, o.m* w >v. ,. e.A..+ <w. .w... ...e..... c,.. .a -- - :..-> ~v ,,,. _. -- T.a.ww. v '. 'T.. '..;. n.,yd, lr. %.;., ?.. 1. r.D.T.%,,.. r N:

  • A AA
g..L.,s..
    • -J,.t :.. i s

....,. ~ !. 6-. t. s..= w s ...,=== n a.? e s. 'm =~ .e.r.n..r.. k n --...y- .L. ,, [. _..,. l.. ,s .-_f.~.s.g O.', r.. g eg.w.s.y .,s r r..7,..,. p* ' - m.(3,y, c.. "*- T.k a,:, ? ae4 t w ..f ~;T ' f. c. .G J.,., ' l2i P.*1

  • g '.

e, ,?,,**. ~ .v .n..e e.. - .*(--,.2.,, _..._.s,s. , co,s ~ e < < s -r,., v,,%. Q*". . - - ~.- s >. w. - .r 7. r s e e s c N-2

  • t'. *F =! t.

t .,/*.?,. _.c, ;. y p t g .., r y. 8/

  • *** 3.4 f..

-o. _ i., W... '.. 310 :.., i g A 1 r. 6, s y.,e 5:=~ 1 6 =. :- _-.. - -~. - _-.,- - ~- ) ar..r..a..o.. _.. f 3;. : . ga d u o.o nar s 'l .g t-78 *.._. g I.:, a t .,2, t .,.,.n e y.r_ spy \\ t q,..[;(a )- c.,. s ., ] .c .a. u. - '.,I. ' _..t.:,._r e,j /,..) i 6 ~ ,'g, 5 M .8 ...'.(. e-L M d \\ .~ d.;LA U - li .t ' S . - ij ,,,u t. .mA

l'l", -
V *Me.

,,j,,[ ^ 80=ma =4 y,. -

ea
:ri::. s:r.-s - : - I, +.

v p. 1-

  • g./

1 .J.*'s.* - Q -. i , f _ ,1. w.. -y ;_.. 4 , r. ::: gw v, - -. =' g-..;..t~= ~ .. ~y' t u.=m l - a a

  • s.* ar>*

r e o. o. . a o my . n a,......_. ;

n. 'N e ~ w - :.~ w..

a siruse,,,ewr.y,,c ee, s s. r / o 8 i g 3,. --w. s ~ tsung r e s,. ?, l 4. i i .t. ..... T _ '.e. e,y -t ,= e - --F- - 1 . lf 2 ? /, 1, -l. s s. N c

z. i

\\., j %l a' />' i n I g .g.f-8_ _ n. 74s to- 'L ./ T-1 96,. i _____e l ^ ."7Q. MERTURE, - i, i y, s. /,

  • l

,Y

s.,s's i{ J'

( g;e 1.',% .. v. -.:. ( e.,.y d, .. ~i .r~ /,,, x D. j [. . h, ' g = .a 2 1 eca..s . 2 2,;, ,__'N.%...,,,,' 1-O., n e* d .e. 4.. g l r .\\..'.'

  • y.., _'.

sd* s; N i . o e g., e 1 ,:2,-. C *.-'.. l a l,.. g.

t...;-

l .i._' ..?.r. 4..,..,.,;.. 4 ,,*y 3.:.;,., =n..me.n. - -p f,=1 .....g '..,. ;,.g. j r.,...W.,., :.*. .. a:'. < * : a..-_.%..... L.a l y e. -..._, j et. .g..... ,. ger 'l. Q.;,. w a 94

  • s *2 5... -

,4 - 3l - - g,r",z,. s * - .g - d3...s g s ,*t 1.*.ht "w. ..,,r..; 4 .... y 'rs.p G. ,y 3.. .. s..- ; -us,;e * ;sp'::.. s E .x.r. <...:. v,. ....... w..a.=. g.p p.., 6..,p:. g;,.,,.gr, p..g ; ;,.y .. a. . w,. l

I Aho Xvi&Mc Un l

C.-tac Ml germrecara ' ~ w-

7prec.Wc.c + l o n 5Cf3i-P-Tlo4--- L pgr.e n 6 Yv. - Ca g.w --. - ..,py.u. u .n Q.v,. %. w. r - - ; --...... s...J.j.g.H &_ i ... - ] f %...m.;; ' M..,Q.,, 'I a a t a,.. - r;.- .!.f :_ =. -: =,:.. :. 7. ..t -..: n ~..* ' m_.__ w. _ ,, w )*..;m.. ..M g . ~. 0. g ..+ t e rs a

.r&z.
.x... -

S.' ** s v 'I 1

  • P-r

. e.. ,.s ab rs.!- g. g) . tg.*".. 1 2

.: v.

r 4 e, .3.-

r..
U w en. o,e.8 i

y ....s* s .:s.. ..,.r. 4 J rsie.s. t.:x:.:: ,"-C .g srs_.. ,t, ur,- r -f. P -r .o,.,o : A. ,,,52*3 yd,...-u ,,-.S.. ,'.'l s..e e ese,, t - :;. s l. p g- .s ..-u. ., f ./ A4*. _./.(u /.. n. 1 .,,.a .e . -. e. ;.3 4

5. ',

S 2.. e a y > - ;sai - .A e. ... ~. w um p.. .e. 1 4 t wlk.n . ; n.c.; :.. -.n

a. c.

p...1

+i e

,N,e s ., -2 o t f m q. . T. .'s. y.. .s ns., .. [g l. f 1. ' gigfx e Ma n .A... s.. y x w. u n J ) par 3 gy ... g \\._....,,,,,... _., 3. pq L _>1 y.-i - @ (- .h-' S -e s 2. l : ) '.. x... y l n. O c,g er i... ..;) ...v. Yl <4f,,f. ~.a-su.,.=-

s. i v

q. m m .,...,o ,.. o. n./ l s. .[ 'f-* l ,,~*, " f. '" """ -1 r- 't - l. [ Y. i f x a , aa, t T L - - - ~ -n.g-- - - - 17. l % 8.G 9C. l. . p p,.,c.o i b,ee, ,4, e,. < <n<. %L*. f fs..f.u.t. I %e ". O 1. ]i k *d* ***"t'a f. A q .. s,, s -s e s..,m a r

v. ;

<-.---...t- '= . = ~ - = ^ = fa** *Nd ** *3 ) 8* r. l' J l l' l' l' l' l' l l' l l" jji -). f e s... 4-g *l'I. p4 a . Eg,. 3 . ~... -. )

h., I.f b b*.. h.t. 4 "g.[
    • ?****

. g ggg j w_ g ,gj i u.e =m - OP..C.6 2 \\ .r. Ae* **=. l .-*~s****. . - /, - 1 g ', .r. u. <,. . c

  • s.. i v..

gema.o 2tst,e m -.a.. 3 es* en - M u... s. s. e -. s o... - 4 .re -.... . <c.. i. s. n., g. ....(* me 'eravuunsomme e.. - - R..% '-'.'.'. P

  • ame 5

~ en p p,,c,c 3,.. ... m.a m-a.. g 47W y. r,,e...,3 e r. as s 2 ./ ,. N k.>. . ; = ' - ~ ~-~. ; j 177~' ram. a. n ~ \\j.$,' g 3, 4,,<-, y. ..o. 2.. ,t c-va*,.** q, 4' ~M~, . c.. .';*....,,.,..e.e sam e<=.. l k N, N./*s y% .c. .: n ./ u. g s ./J y -... r. -. .w. N \\ R*c..,- ....e. ire s v+* s;*. ~ - ~ A ~ ~ me.a / /\\ %e)\\ i ~1 s r a,. ? .ar - r oe.z-l,'... ~..... -. -..... ~..,..; .a .r- %' / ,.,N,} %./.N

  • i

., e,.. \\ l cip / g r,. ..,,a a,. e e. e:,,. v i r.~ ~e.~ <. * \\ \\ /s C -< ~ e,;. =,,..~*.'.t..'.*.*.*<*.^.*." t .1 .s.:,t < x .s.s , t.s

c. J

... ~.,. 1 c.re _ aa ~ y . r.J -s W so =' ? *.~.7.=. p; r;, j r s.... '; seu ie.,=a. s - u~ N _ -.t eg e-,6 m r.;;. 1 .c a r, :','.m e i.y*:-.- -..

~

y og 6 - - q._ N.r _... 4.,..*.*.d'~.r O A,.,.=..p i .av _.u.1.

  1. s

.5 s i, a. p. a 3 ,3 - -..... -..-' ;.,.,..,,,,, _.,..,, e t' a,r,...,.,.,,,,,, j, g .N ...,,.,..... t t g 1 g g,, e e. - cc-. l =.n.--. ~. *.

*.4 a.r -=."..

i .4 'j .......) i,,,,,,.. i

  • .a.,-

s 8 tlk 88 S. Mbi r e...ga v ' e A ,3.. ....,._.,.,-.m., o.. ,r . [. c,4,3.= a..-s v e.= ~,.,,. a n.. -,,, ,. a..- .r..u .g .3 ; ;: V e (. ~. r.. -......,,. a 1 ~. . ~.. l w. 6 -* - . 's.4.. I

  • . E.4

.s --.e.w. =. ,..i.. l.... . u,.,, glgt..o.y e.a Q s ?-. s. \\.. e. e- "i '" %.s, V YUS.a. HEAT. TRAPtSJIA DIVI $1CM.1r

f l l l l.......

g '****.i.i....** s

... i. *tgi t.

,n e,. vse..=ou..=ies wee t -6 .e.r,g,.,l,. s.s..as .s . L,-.. 4w .e -w.yper r-u w,, ),, r., k .Q ~s T .***^4**** l y -Q N.;- ' K:""h ~ris% M n*P-1*** '~* _2 ~[..s4

s. s.Y. \\.*%..*.g ?? ="* ****'
s. i,s e.e, r.o.e..ea*.*.~.e.*w e.s.v...e

.-} . : r...'..c s< w+ .r.s. *ae sw .sw e.- . * ** e. M' m s - ~ ~,,-s-w s ia w 4.pe,.***. ... '". f.yl.*.' @ f,*" ' e - ~.d a . ;. :. MA.,, :,h. ,1 "" ne, Mr, w M

  • r
  • l-e 4J.. '. & 1.e :. ~ 4.S.

g.,,g M, , g. [,,.,.... n;+ e jeas e.e.s s,.qst am 4. + . *". ( ; 4 sin. , a7, 8408140326- ^ U

Sp;cificOtten 8031-P-364 APPENDIX D Scoping P&ID's P-115(b)/10 e

J Specification 8031-P-364 App ndix D LIST OF SCOPING P&ID's: P&ID's No. Title M-01 Main Steam M-04 Vents and Drains Heaters 3, 4, 5 and 6 M-06 Feedwater M-41 Nuclear Boiler M-55 High Pressure. Coolant Injection M-56 HPCI Pump Turbine i 1 4 P-115(b)/10 D-1 Rev. 0 1

A l i ~ ?. i to n-stot l g-a t g.. e net..m .{ EI,m, .=._ g t-.ru. .t== o m i L

m.== =,,,,

n> l a t ED--.. Q.=..;. r,?:: -,.:' E. - " i :'.i --~ w . a.s. Ei .:..r . =.= +-4Eby ;... * :;;==,.@, ..,.....--+ 6-? 1 a' 4 s..] ..b. ,-N f ~~ i ,,,,,,,.m u -} l.@..,..am@. g .,:. g , in 4 ..,,=3

a. :

n. s. n ~ u e= ~e - m a % g v.w + p -rv,v hOn3 l e '7, 5,*'.. E * .h D _ . **..y r .u asaJ PP i 'l 6! ! 4;r/'98 L !.}..t e i i ~ -- i =.< ^i

< M.T.!94 yp'lr-
g B pli:
g..,

.. j G-.

.::::.::::-g) i.

a 1,t; 1'go t ~ $,.H ; >.; pannmm.=r e? @4---, ,o 2iRF. e - i 3 c mi i ww y...,'

y Q-.,

- ~ +.-@q;p. e i e is:.e a ..c a. n 4 I ,,i. o o,. --y 6in c... -) g yrr.: is.:::@:t u . qj t H. o.:.g! I I m. ~ m

r...=

g pp.J=..;a

Q-. U U

~. i3 !.h. ;:j i . f.. . e- .2 = P -- s Oir = -*:::'t.! 8i!-.O,!. i@'".A::' ~.. "au 4'" mm e. . t. .. d,.. JLJk 3 i Q;' ; il: ,ii , i '1 g3 e, s I = g .8 tr > s .lg2 a m.2* C: g i > 3 Ui c c u o Jms.- .D...., o i 8 T@: em w. 7,v.~ g c :. r u.E - m. j;$-(a.gd m. 1.' i f h w,.*,N i i 9 M NOTE _. 9(pacj ;unged.ed te ___ g [",iS r.- "M ;,"- UWd F h ! h-E,j fj"" @-- E?- o 'tr N N.d C T F N M i E L W l (Cw) U denoted a.: bbe I Nk. 3 .d b __I C Ii O.. ,,wj.:.g,y ,., i :, hy 'g. i .--...........} .a i i 1%f":,n! J!'1 =f-E: f.d e;g!g' 2

n a
  1. A

[ red s l-cui. 4o l 1 .g;'W:, 5 "o e e l l -G. 'O - ?-- m.. o,,,@ o,,., u m m o , _hk:, S S I e g, c s. i 8 w

v. ;

o i 4 o .t ~

M~.
.50 l j jG.

1L A. t-I I' , f I i 141; y ?s [;l I .e}- o i s g".. "uT. '] \\ ~_ : i ! c a t o; ;o ] ~ d g;y Aho Available On Aperture Card l,l { { { m.,i::;ng ** g l j j j t o kk it it i gg'TgtE 38% . ~.... o 4 ,I., o a g 3 I !d o p = 3 o O sins o = ] j{21'l1 i,,.,, si ,N l 5 h ~ = o ] w e 1 "[ ,r r r Er r r r7 'll".t",. f i; ] 4 1

  • = *

~=- .I 84 0 814 0 3 2 6 - lJ l.- r-- - - - - " r r 7 f f f f T' .a Se e i gFj. I"*,; ~ 'T,, W .-e g s s s s s s r.. A p ie--. a o I;. y i .a. i,I v. -s 3 c3 S, t J O

g-'"J

.c., a gsris,ir [. -w

' 3 D% \\ $ 05 af [ - h U .,n . QMbD. l o ~s f" m... ...r s ) .. " - - ~ > ' - ~Il. .... = ".. au.u a .sc ~ p. <r a rg ~~a~.~ ' O,,. Q. =h r~f g u o T. n m /.:h ."@"S %'.r* = = i r

w..

=. - a L _Q 'r. Q' d , O.-

  1. :7 e

.o .== L h L..

    • =

r.w. s y no .- ~ .a;.,., =,_ s,,, u-y,,,,,,,,, I* M_ c2.. 7

,,,,,=.

[ ->= fil o, ni .-.>A. c,3.,1 l 4

g...

.W a, ri .,, J

m..I W

.r >.n..~.,,- J r..,- , 3 2. i L m L_ a. O2 ly,a. .x x } t-m

g.s g-.

h-. .p

eg'h E

R. :- EP:qq#) dsje p"**3:. NN N.g/ -" g 4 e,u 4 W V 2 a t.

t..

m

1. w...a t.,,.. u
1.,,..,,.n m

@...mJe @.e. Q.tg k.. 11g4. C,,i u. A-. .. t. e v . u. sn ...o .T (.= fr @.. M @'.. 4* @.? n@- F w".., s G. 7 %.-@. '.? e? @s;s.. ~,, g e @...3.n" a M.. W *. r. ~' - i i ..f

t; e
7..:

g"c.e .y a i, Rp i.: e,.o i .y o I -G., - rl c-DL ' I:L G"e-

  1. + gg o,

_/'_s _M=I

e..

2 2 8 2 r 4yg_ ,gi ,n,e f _I g m,.- t g c 1 : ; -a..=.. c s = '. x.,. e,.g,..

  • L _ a.s vi -- A --

-yj I 5 O fb[~J ..g

g.N $T' h. 1 I -d'

~- ,- ++ r i

m...,

] i m. f"q... e ~ ~ r. l g i n_i_ i,. t._. si____ I 43 -If - I GE>- 1-. GE>. _ @ ,.. b; . _f_ a.y, p%y m.. I Z :~- L =7 ~... i"' g }i 0"h- ~ r >=,.m..., eh ..s 2 s , o,_..- u m %.g_~ "Q..",_ - ~,, 3 +,.y " t< 1 t o " " ...m., -._. s. a, s n e ...n L..- :4_.. r.:# - 1 m g4. e.... g a~ ~ g ,.l 9e

u..

4 g. eu n. q ,C. s_*.. m* ue.

,v Vrs

_ [,.. > :2./ M E

  • .._e @ _s@.

@. v@. . 4. ! do .u." @! d.-D. n- = M. = - = A.3 '.. m S..-@ g y e s..u. c g u c. <~..u.,,.-.. 3<~ Jm.@ Q..~ %.. m. ,V a a=g ge.:** w "'" ~ n ~.... - t @S 3 i li;-E.54e b2-~ " g5 @y -%A... ..s n,.,. -_ - _ _ _ _. n '~ 'gj"i s m i s p a i 3 u '.",r. w , p_: y,o 3 3 m - s. ],3- .,4 y ,g]. l'.',1",,, s o a

== ,g

u....

7 %v, a1 ,a. y i ,.4 -, m m - g m o m ,e 1 .,o m = m L L p.. ta y e.s...,v

g. ~

m =,.. -. _ p.,_g c ~... s*- e._., ..,a m a Y ..,u, n.o S y y y y -. ~ o ~ e p ... - ~..,m. -... c. !.. wh' -. :: "..' 4 A. u r- . u...n p,m - --

m.., m. -

r-u.. A....,.. n....v.... :. i:.c"t., w.. -. =. = = e, u. ..-v....,i... BECHTEL 9 = =. . ~ e. W.*7/. s ;.y; s: 4 y3;,,g ni -. s a.c.~..

u..,c..,,,,,u,,,r,i., n,,ai,ie,,.c,,
i a :

a ..~,,.,.,.,,,,,m,,,,,,,,,,,,,,,,,,,.,. i a ..w m 0ul,s r,g 3 5 .~ ~ -..~.--- ..4. oaeo a "W '=,';"".t"'f:*.03*".:*. ".'l %"a*Wfin'*T.?""""* ""' E a~-==~.

-.~.

Utan2 .a.-

    • m a'"~lll~M Z. -.
7

.O'"."'...""*..**"".".".......T'.".'.;.;.;.'..*".u.".**".'."n'"".. a

  • a.~.'

n~. ,..u.a. sp o.n. n. I son l u os 23 .u. -.----=i.r. ..................... c.. _._ym. ...u.... u.......m...... g n.

4 i . -." ::'t.....

8031 h4 04 l t

} -m'

.~.===

wg A. y.

4. ;,g. p e E=.i:.5.lr. ":

-c a g-. 4 4 -wrc- -c c.;- ,....'...'....'.%n

';;") Y E,c'.?

4 T.f.) 3 .m. : g.3 l =- J._,,,. ". - rF" ;, ' 1.;: c.rm.. -- ;. + ~.:rd .z _f - -. ,4,,. --) 1 ll Q _I g. 1 i g g y o _R5 sh~.!@,"@-@~'.___'.,ci R$. =k w -- -9 a --'g[.," sw-2:.5. ft.Jr@-5 F h b.~.lb' ^ i ,::.::n ';; i f- . m - , m 3@@,.- p,. @ Gj>..e..:. ( F o l7 36........$J,,6 g9. g @ @.; x

n,

.. w -x 4 . l. w.2 4s a ( t. .s.. ....n Yy ~.T~ -

  • 2' e, fee.# c siori e,_'3,,~h = = f rE:h :

1

,, m

& ~~ ~~ go3;p 3(o4 i97 i *- i u 9.- "%9 v tg g+ -,(-,I i3- -." _a"u,.k. e. ll= g . =1 ' ' " = i T yp.ena;g p

.:.I
  • e.= m..,.p. n m i

.-- e . ~,m. .a.p - 4.a c _r 1 g e #

9. y,. ;;m e'

e _1. i _e . r.. y 90u.9. @. Nere:gunf54p. e

g. 4 2-4 rm: :,,

u I .-a._ 5 e !,a w> =so i e o p,.,,,: c_. e i i y i f-1 g ,e p 0

g:.IY

$[ ,_. 3 I. =5 ~d Tro-:

  • i e e 'b t

i 94 cgi.ki:

e. !! ! !

teeh,y.'s A g D =# m@, E 42; . e==, -~ ~ , ~ ge not e d c. 3 q r , t.p. q r,..... ap u + d o',1 %.. y-J@ 5cH m, .st. g.,.. l.. ge

g. _.,

n _ ~~ 1.%=sM. 9.'ee.! c .~ s<i,, a. i r i e. 8.. w _ a : : e 4 ! g.. e m b r._tM y.-d 1 u ,,v,, 5r::. an. m..,f W. 9.- !s s.1

gs,.g -

,c Also Available Gli " g

e p.c
;,g wy i y

. j , :.j j j j ; ',L ggg Aperture cara j., j ; ;

gpe,

(" pet-{' %p+-G i = t .., ~, - s i .3 TI H ; , JS.__g!"D " " o ~ ' APERTURE wes e. eese w, -~ r .t . CARD [ ~~ .. emmi. .. e m.... 3 in... ~~ e 13 4 0 814 0 3 '2 6 - 2_.Q @ J , _ ""-"' y 1 l1 ,A i y.h.h;.. sum D-3 Fev. o-2 ~" 4 e m m

\\

===, e. c 4'm% e N-.. .4 ~@. 9..@._--- 9 g 4iiD T.w. . = ., ).t; F. '24. ; ^^f ~: rw.e .. i e rue e b b iP b b @ $--- --t-.-- .trIoa--'s ,g Ah - h b p ._,) 3.h."..r.....n.T 3

v. m i-e.. m, V, e

nie e inh i a... . ja,;s. _y, ;;. ug $%4a y*"', ' [ .g.g.T a ',,, *, f,. ' l p-t " * ~ ~ y,,,, a., -r-pa ,,=,,, { ,,;;9,)

2..,,,@-l

- -m.. 1e y e; nu 4 g g, g,"g.,pi,Q.'. _ e p: 6:: e. u, s 'G" "i ,4, g o aa u aa 1,,.@ ,m EP ,_-,,--_2.-, i r ."r -.. -c ,.o-a e m ,i. y. m g... - ~' @@-C%,. I ~1, =4,ge--W"F.M...% i R..~5_ l oi,. w i ~ c-e geg. 9 <t g-......e g 9 7 e g i -.. m A i s. m: s... x._,.n o.. g* .-o m c.... Q @ @ -,. .a } az , L,, _...'.n.....',g= m,. Q,. @, @. t--- .N m i.m 2 ---'--.--------------4 .. inn ,. m.. s j~ ..;,. w.

m. ~.

w .m -.._ _ %a s ,. _...,..... s .... m. t i n., _,e.. -- m

ct I D..

e. s. = = E- *--- g ! '.Q'. a s 3 i i. ~

u. w.,on

,k ,jpa c m m- -pi 7, @ F ' '- i @5_- --G k9", _m F + - - i t.:: :. -*-s-------

1. i e

1 y- . +, w _,_, =-- m.o.....==--------I, f- = V., ; 4. v. y e +. k. .c*_?.. _ 9..Q: - " ~ --------:. __u i. t ~ - .,y g ,_ r. . m..,g --._--- _p.. , m u a i i .g. -;g i b m u.... m., ---- _ ----j - .s, o ~ = .!m p / u i

E
,..

~ o' a.. u-i a n..> ----- -- 4 a 4;. r: m .. f.- i n u ..a e,..-.,,-__j Ir i rs c.... fPrIl ,, '.. m. l h j; y *" ) .u '.....<.u. i :n l (. { ,i- - y 3 --I n. m. y.=,. [ {,',,_,, "1 9 4. - 9r.. j * ,,::=,c-g'.-_ l i' E - --- g n =*= .l .*", r.g[' 'D ~..- j g-- g! E -y:: ", g' ge -- 4 i G j Fe;,-,,----- j - -- - - - --- - - - - 2 g 6

  • ""p

@i,. . M r.S" t-i, Q-

9 z-u-&---w' r-ki u

-u i ~ = ., = = -... ~. ;.: ,m , o s s. -oc. = s%g.m,,i g, i.. S. ; h-i, om 2...m.-m.....--.n....... -m a ,,a 4 g _..[t. .. q , a +- 3 - :p ;;:! ! n..-..- u. .s...._ ,j j l 3 ,o a..a..e ..n.- .a a.. a.. a 2

e
g e

m: g _a, 3, g e,e . - ~ ~ -. a..a.. o g V, o r. ... s. 4, e.: w.e ,,,, n, r 1 , ~.. k

s..u.

i. .s s m ( D, ca. i ,....... at - (s"*J @ ,e ,ia , n. t m

m..e.s u.

.,,...........s_.

  • J E..

lato_) [n H #.'.*.I l l 8 (l . I'..E.7.F ?.S. F.*.. t..'s C 8.T.* ". a s..., t t.s s. r.C 5

  1. 3 C? de ja _
  • I 1

~ E.h', #*. a. ..n. I e.tt.o.. ***r s, l 3 [. -* '-i .e 8 .st r.--3$3 ;4 .. "dMf 2-s H.ueEJ .~. . o -I c - a- .**f**-

== *?*

      • "."'.m...'S.'.*.8."..L.'."Sd.'g*,*,*,**

t,-- aw i, c..{ t -e- - -, ,,.,q) ,i -' w.

==. m.. .m =.. m. 4.jr1 3 r s." R i A*, .w =,,w.r,- m os.g 3, .r .t g(--- @+---,"- *7 3(.j, :, I ar. j.,c.; l, % ..:. y' g a n n r ~I 9.1 .. :;,,jt g gwm...... ,g,. 3 0 ,.,,,j <,>,.- g'a ";_ 3 : t t. ".3 @,-9,, t..i dL ";- A y. cf.*.,*.,.,G,.D, g__ i. 4 1r v -... --48'c A B h b e @ L.a v.; (!.".2,, q,,, m'".. l 3

    • -3

- Arw=.'m.a =.= e

1.

!=: ;a = n 3 M a i y e. d. - y m , e , m i:h ' fI.g i $.. l rg.,.lt i AN .= = cma= = nu, FM t4, - ..g w9H 1:9 _? - + - .i-=-:= g i-. .i-u. 1-1 c. 1 B E,,,C,,H,,,T,,E, L g ic,oa m. jt e m -. o eo.o:. sea na*' .t mm i (.se w. si 4 tue ,a um.eascs oe,esearsee stances us.,ts a <l3 d'T d 1 W\\ / l2.- 5-J P&IO g {}j 51 ~j' [* k7 .E. s. n.[..* is.Yn sm.i.s.Id..'.* ta'.":s VENTS 4 0 A41NS ME ATERS 3.4.S & 4 g 2 e Nn ts 3 BBCE s. e- .m f," i,*.*. ^ 8031 M 04 87 8 .E I

i i ,S... l \\ } 2 v. 90.M.itog 4- .= M M:::_: =.. '":.~. 1 i -tw^= __ _

p:e

-l p,, =>:e 1 8W[ de5.,-.;

, r., ;;
i::::

= -. u zm, @h %r J5 ~ $'. 3f8 h.,. - ~-% d.h { + 'gf: m -g G. *.? go c i e. i eF ! = _ _ _ m.m_ _., _1 ,3... 4_:-__ pi@;E :"--.= <-g'@r=-7. q- ,w-il e g.; y f-g% g&t c. u v g' = __"g- -E o S m e=~@ M b w m 7 (':.:':'." l )

e :

--i-i 1 !. O s,-g-- 1 i t l.g syt. IP ; $ ;3 i n 5 :m @hlWj !E 6' gs f 'l*C--'- j I [

M, 7.

,j s %'@bf

f.., ; j

~ % @I era i y%p.: Af ' j .g--.j !! 0 ;a

=:

!i hj. r.1 t-- pQi. ga gg;3 ,,,, y.. !Q..---....-.....-.4%u,ffj&~. g h, ,c . m ~' gi. MTE. Vi@3--.subjec.ta.d h. _. W. - hWMAU'. _TMRIiE.MT__- l-l 4 ... n. '-1"pa[%, y/, .m.. tg'u-testiwg is de.wot.La.s__ ,q,.

!g w

g.g HD ];(j e.- 6y 93 er,-1: r M> W s'. i lf 4 * ~ -W,,,, s yC 3,,,,, -;- !.p i li a g _f:::::::::::::::(

it Eg,fsI
  • p#, g g -&

!.dd I *. !'pF.5dt. L, -m..r 7,, i n....s t., - Q, g .! g u-p [R !4.t J".'. r 4 F@ TI i_ w .-E ~

== APERTURE r =


?.--

ri E= . E[, e.- i, CARD i dm c b ..n,r..d.nl,. , iy, i !g i n I g F.I.ap .T. 1 -* A. VM s u H i z g - f g g y,.. m m {, ,, "" =! 'a i: : -.- lg ; l ?' C l~ n-.L-P i4 P Also Availabic On l('O' d i A; re; j ~ g ,g .f.,. m i,,,, i jj i Aocrtare Card I, ( l .'E,"',' ) - 'l ~~ g d q]'pgp9?..j.'.Q jB j g. ca.,n,m. P[ a. 2 ~ s eu.... ~ s p c : W-'3 I* e. q pc \\ = > x.'..y g -in, ! (m-, g i e i 4 e t.e,!> g - o,. e%.,

M9 3

ei.==~. o i ? - +,, --@ $ ej { ,n-,,- p~ 34 9m.o 9 P -- : .., ( m '" w ' ) +r 4, e.c. i j'-~~ m.,:,.;;._ -m m d'lC "'

  • "Z2D n

=.22* [~1 M MDN-D;*H Ir 9-Y D -I ~ 8408140326-2 /

':>pe.Qica tmo 60 5 i-Y- 364 EmpquM* 1 ~~ y. w, ~ .nr.iu

  • Eg* "_ "_ _y_ g 1l_. m.@_ _-G_ _.

.' A_.d.::U:.:.'!#.i"_6".A".f".."*"' . r_ _9P_ F_ _ _ _"_".". iW g j. g. j ah,8 - - - ' T ~ 7.;.' ~ ~ ' ~ ~ ~ D ' ' ~ ~"~~_~~' e'. .T_f..'_?4%!".J:':'_fi'J._:"J.O.#.,_*._ __. i g. .m.yme,.g,.=.=. -..1.- T .r. -.4, J a. 'ars:::ma:t.mt: Ire:.:re= 7 3:::::n.,::rg.. =vy = -.- = .s ^ I e--= g

  • l::f.'t!".!.!"::11"A 20"/.d'!.'. ?,1. ".6o

~ g=. - rm g-]s%gfe" pg.; .g e @-.' pp y_ '.i p io gd -.a-- = = - - - - _g) L, L! ., w a t. ..eh@ -e-e. r i mri il.._ '* _-r_. J g. f_ t. f.j. "," !g 8_ _ = _ _l _ _ _..___3 m_ I p ___.i____ _______ e ._._c_.____, i o g s ~.. .f." *"* i T C'*."" I g. d H E h k **I

y

?-- ma M 4 (sw.s.re. l ) -.- i g (s.s.rs. l ) ep

== c 3 l. & + _-$- l ,f ..i N W k V [ 4 4 i of 8 l h$

  • r F-*[.!whs
  • e i if k e

d _. I 'rA'@P1['d~w.l~ ~" s e " g. !. .*[ell~j"" C T'

  • i; W

M. 1. g tri I g.% .w : c: i >2 i g, $,

3.,-
g gi, W~

E~ @-----e" ; p *gI,;g c - - g%.$.,p g....n c i

a. _. r_.

.y -m_g ! 4..w s g..., _ i.g = r___. ---.- a q k.g "i32 D*. l brK k YhN#7g 3-l k,g....... M. gfdy j[,6, il m r m e. g i 4 ,: p, w, a s + .m, , u ~" yt.t _ig -[y* y" C.Q F, g l p d" .r 7o.g 4 e a aip@5.g.ll d j m .Lg 1: 14 m3

L L.

~ j$ g,. 2 L:. pi 5 ai w i m p .J.i m;@'- - - t H t

{ i_

2 '-~.t.__ i m g g i i; T=_1LL Ly 4 -e /

q q -,re.

$, m..-@ Vi =_,. .u :e,+

q. A i

~-~ e c +. 'v. p = = =.:_ = = 4 g =* go.e .=.._..______"_m.,"_._'^.m~.~..___ a __ =

~~

k n'E muf "!:l*

== 1:-- ] m g.; h. i==== !? 3=_________________q':- p. Wg .e,.e-w. -== ee a ~ ~ ' " ~ -

  • i :c..

g 4" -;@@ *.~.. to e ,. ca.e. g1:lF g>~.-_.@(,5E% 8 ( @i $,,.e@ i i i i.e--,i i ,,, g,, e),V i u_.,, .i i : ,t i i ;- -,i. y$ e r.a a i. v i v m Ir q.% q E 9 o. .,-_ g i'i ! i '2 1 i' AN. C %.1 'i @J, .i y l-- ; ri-- 1: E 'p7"g. %, ;j h" y.hE*.a.,, .4. e n ig..g 3 U. (,.... ;.. t'T

l l 5l l!

O.j-?1d P (,. c. 4.. 's d@b- => !l ?br - i i ql1i i. iN R i i ~ $.- @r.W ! l 'j g --- g a:1,lc....q.., y lg.,;ll l % q g%w,e w i., i .A, u J, 9 ll [,i g'-@[.....y.a If i,l,gl i i l 3 e ,,,. yyp: g( l ,t.,.. ) f l ..u a) g g_-y__o --- go},lef!_9 j....i. b.F... g --t. e.....

e. M_

m s.p. e 2. ** -..a ~ n. .= a, 4 e% y3,,,-.@@_.gl.-.4-} g =;.a w?.a. a -m u} g, 73 7------ .,E>- - G"A m .Y' =a..,. g m- ,. = m ,. g,g i'~ iI.~s Io'." ) f! ( .Y. ~oh , = ;, U ~,_ ""~~u. i MM.[ 4 ha w.. -eg j -- e. s 3.--p-B--- -a-M.. -.t-g_ _. 4b_g aeCHTIL i s s Il u mcz o nus.e siu.a uinsis ( - = = = M h, ( l W )** ll .n. _.__-- d. u...s,g,p C m( l % T ") ~ ~ ~ ~ ' ~ ~ ~ ~ an- = PA10 % - - -,. - 3 i' = . s FEEDWATER , i tun >. -qp. A AA p t.@... G.__..___ g.2.. ...o. O o s 1 "* M 4 1 _---a sost. M 06 iS n,o, ,uC=Oa0

==== = n.O = S.a 0 r c

9j .s h / l N mmi miqqqqqqqquippiqqqqipli ri"Ii!J rJ JJ J!!!!!!!!!j i \\. 1 8031-W-41 i a 2 j) Nlyg l nur s ."._'a I N .= l4 = n

e..

u8 f g

- s,!

h< e a.ss..

  • t;r,.;'

j .a 4 I in .g e-e ;-i.i..i.t. _g-- I _ A.r l i

  1. I

.tm a !~ l' O. -. _.. E,l. 4> D..,@i rh, L. o, _,,,,u i - - - X g _ _ _ _ _ m _ _.._q ~ g _,,gh =

.:;'a'.=.
  • I r

i

4"?.5*

t L s ~~ f~~ Y. O i> 6{ i, .. ~. I

1. _

w i ; g @4-l h l[- l 3 fcf. S. _ ma- = _ h w.m=J = g 3, - o ~ ~ ,b L I '* F s'- Is a - N. _ e_ <=== I i g j "" J" "g==, Q, f ib 6 i gio. 9.( I_ ' aT .m y '*.".'*. )1L .u sm l F 4 As,q "W.3 3 susi.

i. 4

.,--,-.o w m 'I r a 1,.- r

.

f .?(2, * - ^ 3 gM gns. -( l can HN

  • k

?o-. t .ti.8 ] I8 wmie. maqsigt pre-y=eef % d',=y" ' ' ' ' =: e= k k .S., i W.de. 1_Ffa._b. oust _. = 1 ._L i 'w-Eb a.=. 6 ~ g 9 8:3 >% ===:=:f dy! iD p..mEAW & .f a-- A .g.c .m g D..r 4-...* M _g e e _m m b,; -- -- g x d ". w;m n ha,;lcrm1c f I, x 6 g &.g 4 '3 &3@ ~.:::=.W6 1 2 ...._..,...,q d, s .e O ] Sa= **"= =*.r=*n. r -aaa 1 ag*= t 4a l @-.4 "g'* L i _.., W d ' f N l I @.Q..~' c o r Ma-W 4 i gm..- 3-e o ,$,",,,,,,',",q' p ,.4> = 4> Aho Avre11abb @ p s,,,,rt urc C,ard g, y ;4 i ..... m q 3 I I ^ A l 1 l' TI g ; !!"ljy_l APERTURE i j i Q ':; lp!:rfl_ i CARD y im p ,m,~, = = i 1 i ".:*l O L = m.+,.a ~ = = ~ m m ,,.,,.n -- . -=r =u~_..' -._ e ~_~ "~.=.. '. ~ '.".'." ( 84 0 814 0 3 2 6 2._ $ o ~ ^ ~ 3 = . = = r: = A. -- TS'. - T.3 w. m. m.=..~ =.ia 'M

  • un-x:a.

m.. 1

l

..... t . w .u ... a. s.n. ..u.

3pecspa. ten mm.- r - a + c AppemMO - i ft"I I I I I I I . =a ai 11 71'"1 I I i ! I I I I T 11111 Fl"1 I I'l I I i 1 1 1 1 n o,co m...., -e =a= ,. m .m a.n.-.-a l .,.,,.m_.., _..m r.g-t.,. .. -O. --, 1 -p no = E

a..

n ,.g.,,.

m..

.g# .g. ,,,,,,,,3 q ..m.. o ... ~ s...... s,,... g ..-...e.... ,d.= q s_ mm F1 m..., /.;n. .. 2..*;,..

j< s.

a. g,. sh m. .-a ---.m. .....m.... m. .m,,,.. l. e T.y;g, g. s. m.. ...o j . ___. _) 3 ~i -.-....o-~m.o -m.. n.... j

3.. _

y .-,,,,", t o'

e,,

r ..co a. . a"n, o u.oun .nm.. ~... u- +un.. 3 iv g . =.. .D =.. ..o, o [ 1";. J.g . n.'.=. 5 EiD . 4 -GiDiD I'. u s ~.,. ua un ......m.. o n, 1 ? w m.. .m... . s ~ =. 7 Ip F .m...n.a....,.,...o.... _m.,..o...., i... r, i A. i .e,f ..m.........m.w.. l,. -T_ W,r,f... IJ e i 4 g .= g p .f 2, s u..... .....i.... N=.s. .t T y a . - --i p' 4j> r' j. y.p,. ... l, --g 1. t. j g% 5 -f. ".._.. q r +i." w ...m.s,. g.p,m. I,. (l.rar,,,j.,.JF .= A -- - -- _j.t. A-Q,e-y-Q n .y ...i.*.ua m Ha .a..mm..,w -...,%l - m n .=t a= =. ...... m au u a. e 91, gi ' vus aa -o d 6 Q"p. c,- e m s yui b, -lp@'L,,,e, T, dj{ a,u, ...O =0 u GI 6

g..

' a g,. Siil5 a--- 'as -o -o S, e-" p m .. ~,,. l

    • -_ _ - r - ;

g,.=. j...m o c 3.- g.1 e~, o m q.., o z __..m o _a.... e. ,c u,,


_.m__--

.w r-- l .., v i..e u,, o 3 ......,_m.,.....c m..... M y o s -- -- - r-m a s L ~~~~ l~~~~- ' g _.;c,3 c --..I / p, p, .i. ' @-- s

e. v. >

~... ,l gg,........ a:. u o l .,..~.~~m.. 9 u.~ i.......... ~ c d, d rmomuu.Tp4, g[-----. g Q.im"$5-I, g g.. w 0- --33 1 n 3._. ~. .- i d, @i k 5t4.. @ @-e ',t - -- h '.2-J DF--Gg@ i %.,,.:(.; o ,,,qL, ~~~' A. .g;_ m ! = _ _ _ z_ _ _., ~ R @,, 5.. O.9;p

u..

a % ..m.. 'tgg,f 4,, j., =" nH =ne ti-a4 m F j... i o...... g i ....,,.t ,u. u ~n g .n. -. .. a m .mm...~.....~..~,- m u w =. =.:m =.=.== ,-- a .g. eu. =, t f m 6 =..= s.m a = = m.,. u. a m . m. mw. =.=..m. y .,m.,.

m. m

.t a.....*.. m. ..u ( ,m, ,a 4, m-u v..i a'~ ...n d ._.m,.. ='. - m.m.a . m.i. .. g., m m. - - eoo -n. a .u .m a,. .{=m....mua$ .f wlg l m o ...m.m. --,-m .....} n.

4.,.

,.,,,,,,,,,,,u,,,.,,.,,.. i ~ . S.'8'.'E-F, l! " '" '" g g =m.=a===.. m un.... t --. v v e 0000 "" ::.att,1. ***'a _.. mm.T/."#*. .m ~. [ t

g m

._..___m - c , _ _.._ t. .. A.,u.. _ - . --,. - g. ,-.m.=m.=.--u - - -, < i

m..m o....
a...gg-.

n =a~ ~ I 3 3 g q

i. O..OT -

o O-O*

  • ="""a..aa==~~""a~===.

c

  • ~..=a,.,=.,,.,.,=,m=.=.a==

i: -{;.. L ~ ,a r...o.r-- m ,m.., n - m. a ...u.m. o ,,,,,,,,,,..,.....m y s.. .m .n n,. .u .m.m .m 1 ..- G .u. ,o...... - m. ..um ~ l'---..- . z:::::/."T.=::::'=:::::.f.:: :m L,* + .r------- { i i .m..,.,........ r- ,.--_i-_ .m.,.,.o........ i .... ~. i- _ _ _., - - --- i - _-3 g.,=m. m,,,gg.g.m [ - ~N c.",. !, @ i, l '___ T__T' p. - e, - A.. m- +- mo

.. =.....=,= : n't =...:

s e i_ me 3~........~,m..,._ i i, i, 2 i E -,rr ,. c--,, ---,1.. g_ .,,m6.,.. 3.f.v....-,J,w.w,.. .e.

t-g3

,;.cc c a. i---. r a r,,,,...,,,. ..- w- = gg i-. i-i.:. g' g' g .B..E.C. H..T..E..L. . = = e ~ = m.-= m. ~ ._..+.m.m. m m n m.. .s-w._. i- -=~- . m nu n.u e

= = =

n. ..i .. mu r, ::,,,,3,,,,,, j.- .g,g::;: m ,o. ...m p ai0 m + f- .lfm- .==- C .v.- ss:zr .,,,,-I-a,q .a fuCLtAR BolttR

    • d,.H,a',

A a.e=u=a T.: w '.g a= 5 ;;;; '. ..u m. ..o. .n. r.u...u...a. ..u -.a 8031 M.41 te in .u ru. . =a ru .o .m my

i 1 4 ~) w (m r-

==. - Ml!!Il lt!!I!QIlltt!!11tilliffilillllllll!!illi 79lllllJ)))l]I1!]!], 0 y \\ ) 8031M 55 I l 8 ^,, of., f. b ! manas 4l:. i i 1 l =S S22 I l L ___ p C F ' l$.r2,rs ~ is M.M@' !- r ::=

== i i g ly '- i 1

s LF'E L-m I

J C g 7.g. 7. g,_g, L-, t. e t J 4 O"g:., .I a4 ...., e

r....,

.t.:D.@R r qr u-r ,,w k! Y . T... u rta ;, y,. - - 1.1 I. ."1 N ".2 ......l r .u t..u.s [ lI E* ,wTE: Jipie3. s419c10.d % I (s,/ l

19. h"~~_a

[j 1 w w c tuosi w r .a Dett y is dan s.ed a.!.. __ f O l [ E k s f ^ .a ll j{ gr.r phns:

  • il ' g I

is / ::::::::::::::::: [ i' hh r L:e 59_*? i u -w-m i._

qe i v1.t t

i.m e j .-3, __ _, 3 I -d-EB 4 c >e -u t,bl e 15"w G Aiso Arailalale On ie +, - -, =- __: _ f z--- n -_-. I = Aperture Card jO ,,,,,,,1,,,, y 'g t,

n. e....

,_,4, g APERTURE lg g-g .,-_ a E in ,,,,,,, 9-qt ) g g.4 Ft 'u.I2 G. CARD t J "4"-fg--. @- 7--@T--<;gP t l t y -~t&-e J l 84 0 814 0 3 2 6 -1f .$ + + >.I. ! i i . 3, Q-to' 9aD

hME C 3.D50% 0C N-E-N4 , hpp(VN d.i N . f.-,.- -- - m tj fl'"I I I I I I I I I I 1111 i ff*1 I I I I I I I I I I FF"i I I III I "" C i I 8 II s y* p c-- 8 i H 3f ) i ' i ....m.. wa 3,.,1; Fln n.......

i..........u..uu.

i@i. 3 e i ....m.. I I i si N. o__ 5-4 ~. , git., I. i. .m_ -- -- t, m.~.~ .......-..e .....m..... -.ri,we.s. S .r-- N g: g g.. ,rr.. r...c..._ w w w i i : .m._m .m...- g a;.q i Q,, i ,...). i a .._,.a. 3-4; u.-- 6

8 3,. 3.
u. d.h i m.:
u. mm...

. m. i ma.o -o .~

  • ~

=' mo -o -s Esu e t .'=. n m m - o o IM'f un I p' i i l I o a u s i'ti T" t A i i l '.--,* +kI y ni. ir._._J.; ____...... l" '= _m m .m. lM e M - ~.=.:::::=.=1::." g".,._ -_g$..e. _,... i,Mi.1-gg" ,u ,_.; r ii r .3

  • t.=..:=a".:::::.===.:

i i , _i , l . s. m i i ,s io. $ lli-l [dE. 1 0 d f. l .E I ! 5 M-E-EE E.E.I'** ** "' i. m,,.,., e .....m.... i i 4 ~ ---4 .} , 'q.l.3,@@,?~ s -mm. i .qq i .m m..-- im .:::, - : _i m, o r .I $i q~ ,,,,..=r-e

4. i mm..-....

a. ~ ,1 u .8.. I r


=...n

.n .n. c. '3 y.,,, 4;p,-Ii gg I -~ f, g wm it ..m.... .....a. , _4 w-. t.,.,. 6 = y. 4._ m a.~ c. m...v.. _, m i u ,,..n,ru. g-E, , w, - .!.T...M..- _.

== _ _:.4-J.._ j = L: = i w Elf.@_.!, 8.m. m i, ...,e 1 ~ eg i. .~. 1 e i g,, p., l-c m.m =..am -m. d.h1 t., d p:.',, "" ". v;=.g = ==== = = p*, ,,f.1

s. l 4

= .o _m = i 1 M i

r. v.....u

. m .mu c ... w., a d I= t,l. 3 i. M.. 1 s m... .Q, @ i- @. o.T. e---- ..m.....m..... i ; i ,:11 i-im. 3 a i. L_ o- - --_1 ai- .. -. - = ~. - - - ~ ~ -. .m. -!-- r., - -s y ,u,

s..s.

3 -- - _J.-4 h'. _ ,,,n.. =...:.: n t..,.= i-- - - g.w---l- .m. .....o .. ~. = gg-l l .m m- = = i; ;.u ...i. a. m. 5 n .im

h. !P:'agi l. -- id-i--iip-3, i

-fp ! " - - - - - ~ ' l1 & l D,,,,, W,---.-fig . ".'[- ::"-" .a it p i i %e l* *"" ! j A h I ^ i yi a w.=-- - .mm_ g l l l ZL.V."."..*i 7;*?t.:; nru. rQ AM P.F.P.'."Wi""" " t. '.C l l Ai%. .-M.M a c'. -0a .".... _, r z. i

r___,

m ), i a i m I .,= l l 3 i (5 1 -.. i i -.i. - .n. _ = _ -i_ l}- ~m 6, I i I .B..E.C.D..T..E..L. t .g i mt i i i l l. I -i a e o m, . n I """1.",.* "= g h I g I i, - -- - - ~ j m l : Y ".:'.'." 3 9 i* p&io t = <Y' .E. nica ntssues coeuar succ6 .t * ll'W

lN' y

8031 W 55 to

i 1 g nwnnnetwyvyyynyyytyve a v ilIIII1111111111L i 95r88109 I l i 1 -m p 7 Twent surtsvecer assvaunsterrareen Twup.s insanas ca. Test systsas maams g __m_-m___.g i=.,= r____,= = i 1 @_-rw--_-sT. .i.. i. i l, @u-QM?ensa--5*

  1. a naua--R*

g _...mee_____g=. O @ "" "'---8 ~I [.. u___ m l. ~ = __,_ - _ d i !' =nea _.--m_ __ _8L 1 l F i _Fl!1*PE 2"!l*.'.T!! y' l ~- ',,. ____. y _...-- ry, qm y, a,c _____3 s I ! ____. = - ! l-e-Q soTE m?tg _sAlecM ro _ g& m e--g_jE.i4,,..Q., g; 1 i s EGG l { _MontMt TRAusiERT... JP-- j = i e ,; yg .. m.,m w m e j C l i tastm, ps denoted..as_ i_" t _i. e,.ste_ms.n.,,4 I jobs-s=.mm_ 2'*"-* -rA *- '---1 Fi.t"i'3_'_*A., r r 8 -"ggj", ;*"'+-.g- -* p. I 00:0000:000;00 m n et s n J J g g 6 tunei.e m eo p___g I s c i ,1 6 1 [*$r Al O g,2:n,e,_y_f gerw,,_; m I i TI APERTURE \\\\ . CARD l 84 0 814 0 3 2 6 -3 D 1 A 3-7 Re.o I 1 m..

[ AppenW 3. }. L1 Ff"'l i I ! ! I I I I J 11111 Ff"I I I I I I I I I I 1 Ff"1 I I I I I I

  • ===

a 6 I i ( w ? 19.fC. C o a Y.".<o,. u.a..... i.c... M I s..... _.m. _i Ir s i. I ,i .m. 7 1 r o....,. _ _,. a ~. . ~ ~..... 1 i ....,.......m.<... - _a 2. .. m. ....,,m. 1 f I3 GH. 8 _g"_g_,i ____J m -= e o .a -a -a _I, I .. ua .o -a -m i 3 ..oa -s o I- *M' 1::::::::=":::. =

___: ::7 a

W. =m. 1-N.l l e @~ I % @-NI:%. ~ 0 - d u. ~' W - Q.. -

=.***='====="=.="a'

.2& '

Q.. e ~ "" 4 .M_ .t'0.;.".M".'.:.:::"2." :."Tha.",. si. L'- - o 41:[ N s, mn... =eci,vue -qIs t.D m,, ' 8""" 3. =.=~a u '.'.n*=.=.='.'*.-.=a=*~*-- t 7 =- r -... n % m v u.e.. s m.m.".."=~ 5

=

1 1 wa""a* .m ma. ...a=... q. t1 pr.3 3 7 - pg nM ~aa

w. a.

.g &r.r. 3 . t._ n.) ci ,I_ t. h..s;.m. v.:., ._ n.a.--u .i, .e. .a,, _ _ m i

==. = = w a em_. y, <g il 5 4 y (,4""_ ....m *-= 3 'f g. g ' I J v2: @% I = ., ~, .i t = m.. m l

.r D

g"" G.. } ,f _____1__,__ c ~ . -- G* t-@.nh 3 i .ir ... ar.r I ,,"- v -- @" 8'-f g 8 Q g i 20$ ,9; $tf-h-,g' s j g{ na a m m m Mn'e 4 3 j@ eg,. 9 9 9 9h" J," >" s? ~ *~ ~ -I w*_:.-, i f ,.___ __T c _. _. _: _. W-e i i + 4j,--- 1 i__-_ __ g ___ i __a n e .m. 4 ga,e O i as===- w<:,9oer.9u ~=.. e- - m.:. mx ,, u, u .e : r.,e m.a. .m.. y m

3r^

g 2 59 Die: " M. s.m-i . e-6-----.:

g,,,p. !

.u e.s,.;.c... g. mi ..._o_ s -....i-...iu i (_ .w " -E .B.E.C.E..T..E..L. 1 I 6 0 .al ICE 6 M. A.f G.u.,Af.0 U.S.S.&3 -tb 0 ee 3 3 I r I 8, P 4 6. ~l l g i .ci.... rue.in j O { f if l i s. on wss i. \\ .~.=.u.

Sp;cificction 8031-P-364 Appendix E APPENDIX E Acceptance Criteria P-ll5(b)/10 L

SpecificStion 8031-P-364 Appendix E STARIUP TRANSIENT TEST INSIMMENIS FOR MAIN SIEAM LINE B AND BYPASS TO VALVES Incation Instrtment 1 or SK-M-Axis Design Acceptance Ntaber Data Point No. Dir. Maximta Response Ctmnent Deleted DL.Y.A.01 B49 1503 Y DL.X. A.02 B46 1503 X Deleted DL.S.A.03 B41 1503 SKEW (1) i 9300 lb. +50'V skew DL.S.A.04 B41 1503 SKEW (2) 111100 lb. +40'V skew Deleted DL.X.A.05 B40 1503 X Deleted DL.Z.A.06 B30 1503 2 DL.S. A.07 B23 1503 SKEW (1) 1 5500 lb. +28.82*V skew DL.S.A.08 B23 1503 SKEW (2) 1 5500 lb. -28.82*V skew DL.Z. A.09 B18 1503 2 160000 lb. DL.Z.A.10 P3A 1504 2 126300 lb. DL.S.A.ll PS6 1504 SKEW (1) 1 6000 lb. +25.54'V skew DL.S.A.12 PS6 1504 SKEW (2) 1 6000 lb. -25.54*V skew DL.Y.A.13 B33 1503 Y 1 2300 lb. DL.X. A.14 S43 1503 X 1 110000 lb. DP..A.01 PP101B 1503 NCNE i 140 psi DP..A.02 PP138B 1503 NONE i 140 psi DP..A.03 PP101A 1502 NONE i 140 psi DP..A.04 PP101C 1500 NCNE i 140 psi l DP..A.05 PP101D 1501 NONE i 140 psi Deleted h DD..A.01 MSV-4 1503 AXIAL Notes: 1. See Appendix 'B' t P-115(b)/14 E-1 Rev. 1 i

Specification 8031-P-364 Appendix E l STARIUP TRANSIENT TEST INSTRLMENTS FOR FEEIMATER IDOP A (I/C) Iccation Instrinnent 1 or SK-M-Axis Design Expected 2 Number Data Point No. Dir. Maxinnan Response Ccunent3 VA.X.B.04 145B 1552 X 3.76 in/sec. On 20" header VA.X.B.05 165 1552 X 3.76 ir1/sec. On 12" riser VA.X.B.02 96 1552 X 3.76 in/sec. On 20" header VA.Y.B.03 107 1552 Y 3.76 in/sec. On 12" riser VA.Z.B.01 60B 1552 2 3.76 in/sec. On 12" riser N MES: 1. See Appendix 'B' 2. Peak velocity; frtan time-history to be derived frcm accelerometer j test records 3. Accelerometers are also used for steady state vibration testing per 8031-P-363 I l i P-115(b)/14 E-2 Rev. 0 t l l

Specification 8031-P-364 Appendix E STARIUP TRANSIENT TEST INSTRUMENIS FOR FEEDOGER LINES AND HEADER (0/C) Iocation Instrunent 1 or SK-M - Axis Design Acceptance 2,3 i -- Number Data Point No. Dir. Maxinaan Response Cement 5 VA.X.C.01 13 1555 X 4.05 in/sec. at valve operator VA.Z.C.02 15 E 1555 Z 4.05 in/sec. at elbow end VA.Z.C.03 39 1554 2 4.05 in/sec. at valve operator pressure tap DP..C.01 PPil8A Note 4 NONE 1 pressure tap DP..C.02 PPll8B Note 4 NONE pressure tap DP..C.03 PPll8C Note 4 NONE i j Notes: 1. See Appendix 'B' 2. Accelermater output to provide velocity transient time-history 3. Cynanic pressure transient not for test acceptance. Measuring cavice s.'ould have capacity 400 psi full scale dynanic pressure. 4. Feedwater Heater vendor print 98031-M-4-10-13BC. P&ID No. M-6, Rev. 16 5. Accelermeters are also used for steady state vibration testing per 8031-P-363. P-ll5(b)/14 E-3 Rev. 0 _ --. - -.. ~.., _..

Specification 8031-P-364 Appendix E STARIUP TRANSIENT TEST INS'IRLMENIS FOR HPCI STEAM SUPPLY PIPING, INSIDE C0tfrAI! MENT Iccation or SK-M-Axis -Design Acceptance 2,3 Instrument 1 Nud)er Data Point No. Dir. Maximum Response Ca ment 4 DL.S.D.01 217 1592 SKEN 1.0 Kips DL.Y.D.02 316 1592 Y 1.0 Kips VA.X.D.01 200 E 1592 X 2.48 in/sec. Elbow end VA.X.D.02 212 1592 X 2.48 in/sec. VA.Y.D.03 400 1592 Y 2.48 in/sec. Valve operator s l NorES: 1. See Appendix 'B' 2. No dynamic analysis performed for this system. Small (1.0 kip) loads representative of low expected response. 3. Peak velocity obtained from velocity time-history to be derived frce the accelerometer test records. 4. Accelermeters are also used for steady state vibration testing per 8031-F363. P-115(b)/14 E-4 Rev. 0

Specification 8031-P-364 Appendix E STARIUP TRANSIENT TEST INSIMNENIS EUR 1 HPCI STEAM SUPPLY PIPING,' OtJISIDE ColfrAIPMENT I.ocation Instrument or SK-l+- Axis Design Acceptance,3 1 2 NLsuber Data Point No. Dir. Maximun Response Ocnnent4 DL.X.E.01 22 1556B X 1.5 Kips Snubber DL.Z.E.02 63 1556B Z l.5 Kips Snubber b VA.X.E.02 47 1556A X 2.83 iVsec. VA.X.E.03 75A 1556A X 2.83 iVsec. VA.X.E.01 16 1556A X 2.83 in/sec. Valve operator NCTIES: 1. See Appendix 'B' 2. No dynamic analysis performed for this systen. Snall (1.5 kip) loads representative of small expected response 3. Peak velocity; obtained fran velocity time-history to be derived fran acceleraneter test records. 4. Acceleroneters are also used for steady state vibration testing per 8031-P-363. P-ll5(b)/14 E-5 Rev. 1

Specification 8031-P-364 Appendix E STARIUP TRANSIENT TEST INSIMMNIS DATA EOR MSRV DISCHABGE LINE J Iccation I or SK-M-Axis Design Acceptance Instrunent Nunber Data Point No. Dir. Maximun Response Otanent DL.S.R.01 330 1794 SKEN i 6700 lb. DL.S.R.02 335 1794 SKEW i 5700 lb. DL.Z.R.03 355 1794 Z 1 6700 lb. DL.Y.R.04 357 1794 Y 1 5600 lb. DL.Y.R.05 365 1794 Y 124400 lb. DL.S.R.06 372 1794 SKEW 112600 lb. l& DL.Z.R.07 373 1794 2 1 4800 lb. DL.S.R.08 380 1794 SKEW i 5400 lb. DL.S.R.09 381 1794 SKEW i 6800 lb. DL.Y.R.10 390 1794 Y 1 7000 lb. lb DD..R.01 312 1794 AXIAL Deleted DP..R.01 340 1794 None Deleted NOIE: 1. See Appendix 'B' P-ll5(b)/14 E-6 Rev. 1

i specification 8031-P-364 Appendix E ~ STARIUP TRANSIENT TEST INSTRtNENTS DATA EDR FEEIMATER HEATER DRAIN Incation Instrtment 1 or SK-M-Axis Design Acceptance Ntznber Data Point No. Dir. Maxim m Response C%mnent DD.X.S.01 258 332 X 6.0 i vsec Note 2 DD.Y.S.03 75B 332 Y 6.0 ivsec DD.Z.S.04 75E 332 2 6.0 iWsec DD.Y.S.05 90E 332 Y 6.0 iWsec DS..S.01 TS1 332 1 4007 g, DS..S.02 TS1 332 1 2007 4 DS..S.03 TS1 332 1 2007g DS..S.04 151 332 1140ps DS..S.05 TS2 332 1 4007( DS..S.06 TS2 332 1 200p c DS..S.07 TS2 332 1200pE DS..S.08 TS2 332 1 20074 DS..S.09 TS2 332 1 20074 DS..S.10 TS1 332 1140p(, NorES: 1. See Appendix 'B' ~ 2. Peak velocity; obtained frcm velocity time-history to be derived fran displacement transducers test records. P-115(b)/14 E-7 Rev. 1 l l -. -}}