ML20094G893
| ML20094G893 | |
| Person / Time | |
|---|---|
| Site: | Limerick |
| Issue date: | 12/31/1991 |
| From: | Doering J PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC |
| To: | |
| Shared Package | |
| ML20094G886 | List: |
| References | |
| NUDOCS 9203040328 | |
| Download: ML20094G893 (30) | |
Text
c.,
3927007790 0-Pl!ILADELPl!IA ELECTRIC COMPANY LIMERICK GENERATING STATION DOCKET NO. 50-352 (Unit 1)
DOCKET No. 50-353 (Unit 2)
Tower No. 1 Joint Frequency Distributions of Wind Speed and Direction by O
Atmospheric Stability Class 1991 Report No. 7 Submitted to The United States Regulatory Commission Pursuant to Facility Operating License NPF-39 (Unit 1) and NPF-85-(Unit 2)
Preparation Directed by:
G. M. Leitch, Vice President Limerick Generating Station
//
O a.<oserre,:ar.,1anef48m.e.r
$$S3183S$ oSSShj2 R
b^
~ 3 p
J 39270 0790 LCS - CIXED-uOOE RELEASE REACTOR ENCLOSURE (SOUTN VENT) IC91 NO DECAY. UNDEPLETED e
CORRECTED FOR OPEN TERRAIN RECIRCULATION CORRECTED FOR OPEN TERRAIN RECIRCULATION USING SPECIAL TERRAIN ADJUSTWENT FACTORS ANNUAL AVERAGE CHI /O (SEC/WETER CUBED)
DISTANCE IN WILES SECTOR
.e.256 e.See 6.75e i.eee 1.see 2.ees 2.see 3.eee 3.5ee 4.ees 4.5ee S
7.706E-87 2.683E-07 1.565E-07 1.114E-07 7.15eE-08 5.222E-08 4.059E-08 3.279E-08 2.723E-88 2.31eE-08 1.993E-88 SSW 6.145E-07 2.082E-87 1.220E-07 8.855E-e8 5. 687E-08 4.396E-08 3.47eE-e8 2.837E-08 2.379E-98 2.e34E-e8 1.767E-08 SW 5.731E-e7 1.949E-07 1.16eE-67 8.542E-08 5.844E-e8 4.46eE-05 3.573E-08 2.948E-08 2.488E-08 2.138E-98 1.863E-08 WSW 9.430E-07 3.388E-87 1.993E-87 1.466E-07 9.838E-08 7.361E-08 5.805E-88 4.734E-e8 3.958E-08 3.374E-08 2.922E-e8 W
1.331E-96 4.496E-87 2.561E-87 1.889E-67 5.148E-07 8.290E-e8 6.446E-e8 5.215E-e8 4.341E-88 3.692E-68 3.193E-88 WNW 6.944E-87 2.297E-97 1.324E-07 9.475E-08 6.282E-08 4.713E-08 3.757E-98 3.897E-08 2.616E-08 2.25eE-e8 1.965E-e8 NW 8.744E-87 2.821E-87 1.599E-97 1.140E-07 7.675E-88 5.903E-88 4.783E-88 3.988E-88 3.395E-88 2.938E-98 2.578E-08 NNW 1.019E-96 3.324E-87 1.966E-97 1.435E-87 9.627E-98 7.268E-08 5.787E-08 4.772E-08 4.033E-e8 3.473E-e8 3.037E-88 N
2.389E-86 7.33eE-87 4.164E-07 2.914E-07 1.854E-07 1.365E-87 1.077E-07 8.832E-08 7.441E-88 6.398E-08 5.590E-08 NNE 3.744E-e8 1.18eE-96 6.591E-87 4.615E-87 2.953E-07 2.186E-67 1.734E-07 1.430E-e7 1.212E-97 1.e47E-07 9.199E-08 NE 4.111E-86 1.267E-96 6.978E-07 4.928E-e7 3.236E-07 2.444E-97 1.967E-67 1.639E-07 1.40eE-97 1.218E-07 1.075E-07 ENE 3.879E-e6 9.863E-87 6.819E-07 4.484E-97 3.058E-07 2.305E-87 1.843E-07 1.525E-87 1.294E-07 1.119E-97 9.826E-08 E
3.789E-86 1.241E-06 7.36BE-07 5.382E-87 3.439E-07 2.528E-87 1.984E-07 1.62tE-07 1.362E-07 1.169E-07 1.921E-97 ESE 4.879E-86 1.591E-es 8.811E-07 5.958E-87 3.544E-07 2.477E-67 1.881E-07 1.50eE-07 1.237E-97 1.e46E-87 9.014E-08 SE 2.117E-86 7.181E-07 3.997E-e7 2.726E-87 1.637E-07 1.147E-87 8.782E-08 6.926E-08 5.699E-08 4.807E-08 4.132E-08
$$E 1.223E-96 4.113E-87 2.288E-87 1.572E-e7 9.621E-68 6.844E-08 5.244E-08 4.202E-48 3.474E-08 2.94eE-08 2.533E-08 ANNUAL AVERAGE CHI /Q (SEC/WETER CUBED)
DISTANCE IN WILES DEARING 5.eee 7.500 18.800 15.009 28.000 25.000 30.000 35.000 40.e00 45.000 Se.eee 1.745E-88 1.034E-88 7.076E-89 4.124E-09 2.81oE-89 2.892E-e9 1.642E-89 1.339E-89 1.122E-49 9.600E-te 8.354E-te SSW 1.555E-88 9.485E-99 6.512E-69 3.848E-09 2.645E-89 1.974E-99 1.554E-e9 1.269E-89 1.065E-69 9.126E-te 7.948E-te SW 1.644E-08 9.991E-89 6.932E-89 4.te5E-e9 2.825E-89 2.111E-89 1.664E-09 1.36eE-09 1.142E-89 9.795E-te 8.537E-t e WSW 2.565E-e8 1.53eE-88 1.85eE-88 6.129E-99 4.18eE-89 3.104E-89 2.433E-89 1.981E-99 1.658E-e9 1. 418E-99 1.233E-0 9 W
2.861E-88 1.677E-98 1.157E-98 6.841E-89 4.714E-99 3.532E-89 2.791E-99 2.289E-89 1.928E-99 1.657E-89 1.448E-89 WNW 1.737E-88 1.068E-88 7.479E-e* 4.49BE-e9 3.132E-89 2.363E-49 1 ~ 76E-99 1.544E-99 1.385E-09 1.124E-69 9.644E-te NW 2.288E-98 1.421E-98 1.691E-es 6.851E-69 4.223E-89 3.192E-69 2.539E-89 2.992E-69 1.769E-89 1.52EE-39 1.337E-e9 NNW 2.689E-98 1.664E-88 1.173E-88 7.124E-99 4.*92E-e9 3.784E-89 3.918E-99 2.489E-99 2.198E-99 1.82eE-99 1.597E-03 N
4.948E-08 3.965E-98 2.16SE-88 1.325E-98 9.335E-e9 7.111E-99 5.693E-99 4.718E-99 4.ee9E-89 3.474E-99 3.056E-69 NNE 8.184E-88 5.182E-es 3.725E-88 2.329E-88 1.667E-e8 1.285E-08 1.e38E-68 8.662E-49 7.486E-99 6.44SE-89 5.6980-09 NE 9.611E-e8 6.178E-98 4.482E-98 2.833E-98 2.941E-08 1.58eE-88 1.281E-88 1.072E-98 9.19eE-99 8.819E-89 7.998L.99 ENE 8.742E-88 5.529E-e8 3.967E-88 2.472E-88 1.764E-98 1.357E-68 1.894E-e8 9.116E-89 7.784E-89 6.771E-99 5.977E-09 E
9.934E-98 5.617E-88 3.989E-08 2.454E-98 1.738E-08 1.328E-88 1.866E-68 8.855E-09 7.538E-49 6.541E-09 5.761E-09 ESE 7.891E-88 4.718E-98 3.268E-98 1.948E-88 1.353E-08 1.021E-68 8.198E-69 6.677E-89 5.645E-89 4.869E-69 4.267E-09 SE 3.689E-98 2.137E-e8 1.468E-08 8.651E-09 5.961E-09 4.467E-99 3.53eE-89 2.894E-89 2.438E-89 2.896E-09 1.831E-09 SSE 2.217E-88 1.317E-98 9.e56E-89 5.326E-09 3.659E-09 2.735E-99 2.157E-99 1.765E-99 1.484E-09 1.274E-09 1.112E-89 CHI /Q (SEC/WETER CUBED) FOR EACH SEGWENT SECMENT DOUNDARIES IN WILES CIRECTION
.5-1 1-2 2-3 3-4 4-5 5-16 to-2e 29-30 30-4e 4e-se FROW SITE 5
1.613E-07 7.179E-88 4.057E-eE' 2.725E-98 1.995E-08 1.e47E-e8 4.198E-69 2.185E-99 1.343E-09 9.616E-10 SSW 1.263E-e7 5.884E-e8 3.464E-88 2.378E-98 1.76CE-08 9.486E-69
- 3. 99?E-e9 1.985E-09 1.273E-09 9.142E-10 SW 1.19 9E-07 5.828E-88 3.560E-08 2.486E-98 1.863E-08 1.ee6E-08 4.164E-09 2.122E-09 1.364E-e9 9.8110-18 WSW 2.051E-67 9.810E-88 5.792E-08 3.957E-e8 2.924E-08 1.547E-08 6.233E-09 3.122E-99 1.987E-09 1.421E-89 W
2.652E-97 1.148E-07 8.446E-08 4.343E-88 3.196E-08 1.696E-08 6.947E-09 3.551E- 09 2.295E-09 1.66eE-99 WNW 1.373E-07 6.288E-e8 3.748E-e8 2.614E-98 1.965E-08 1.874E-08 4.553E-49 2.373E-09 1.548E-09 1.126E-09 NW 1.667E-e7 7.715E-08 4.764E-88 3.39eE-08 2.577E-98 1.427E-eS 6.118E-09 3.266E-09 2.097E-09 1.528E-89 NNW 2.032E-e7 9.624E-08 5.774E-88 4.e31E-88 3.037E-08 1.674E-88 7.201E-99 3.799E-09 2.494E-09 1.823E-09 N
4.312E-07 1.872E-07 1.076E-87 7.441E-08 5.592E-08 3.085E-88 1.338E-08 7.13 7E-69 4.727E-09 3.478E-89 NNE 6.869E-07 2.981E-07 1.733E-87 1.211E-97 9.201E-08 5.202E-98 2.345E-08 1.288E-08
- 8. 674 E-09 6.455E-49 NE 7.332E-07 3.260E-87 1.963E-07 1.3e9E-87 1.075E-07 6.187E-98 2.848E-08 1.584E-08 1.074E-e8 8.025E-89 ENE 6.191E-07 3.037E-07 1.839E-e7
".**'E-e7 9.828E-08 5.549E-08 2.490E-08 1.36eE-08 9.129E-09 6.777E-09 E
7.570E-07 3.448E-07 1.984E-07
- 1. 363E-27 1.021E-07 5.653E-05 2.477E-08 1.333E-08 8.87eE-09 6.547E-09 ESE 9.120E-07 3.606E-07 1.888E-07 1.240E-07 9.027E-08 4.779E-08 1.977E-08 1.025E-08 6.693E-09 4.876E-09 SE 4.122E-07 1.661E-07 8.730E-08 5.710E-e8 4.138E-08 2.167E-08 8.796E-09 4.49eE-09 2.902E-e9
- 2. 099E-09 SSE 2.375E-07 9.741E-08 5.254E-08 3.479E-08 2.537E-e8 1.334E-08 5.414E-03 2.75eE-09 1.77eE-09 1.276E-09
I 392700 C[s0 LCS - WIXED-WODE RELEASE REACTOR ENCLOSURE (SOUTH VENT) 1991 2.268 DAY DECAY. UNDEPLETED CORRECTED FOR OPEN TERRAIN RECIRCULATION CORRECTED FOR OPEN TERRAIN RECIRCULATION USING $8ECIAL TERRAIN ADJUSTWENT FACTORS v
i ANNUAL AVERAGE CHI /O (SEC/WETER CUBED)
DISTANCE IN WILES SECTOR e.256 8.500 e.750 1.000 1.500 2.ees 2.500 3.000 3.500 4.000 4.5e0 7.7e tE-67 2.68eE-67 1.562E-67 1.111E-07 7.123E-98 5.196E-08 4.934E-e8 3.254E-08 2.699E-08 2.286E-08 1.97eE-48 SSW 6.140E-87 2.679E-97 1.217E-67 8.830E-e8 5.862E-88 4.372E-98 3.447E-88 2.813E-e8 2.356E-08 2.011E-88 SW 5.725E-87 1.945E-87 1.157E-87 8.515E-88 5.817E-08 4.433E-98 3.546E-98 2.922E-e8 2.462E-08 2.112E-08 1.838E-05 1.745E-88 j
WSW 9.422E-87 3.383E-97 1.989E-87 1.462E-07 9.799E-08 7.322E-98 5. 766E-98 4.696E-68 3.920E-88 3.337E-e8 2.886E-98 W
1.33eE-66 4.489E-87 2.555E-67 1.795E-87 1.136E-97 8.247E-98 6.403E-88 5.174E-98 4.300E-e8 3.651E-08 3.154E-98 WNW 6.938E-97 2.293E-87 1.321E-97 9.445E-88 6.233E-98 4.684E-88 3.728E-98 3.968E-e8 2.587E-e8 2.222E-GE 1.937E-88 NW 8.736E-87 2.815E-97 1.595E-e7 1.136E-e7 7.636E-88 5.863E-88 4.743E-88 3.947E-98 3.355E-88 2.898E-98 2.538E-88 NNW 1.ee9E-66 3.318E-07 1.968E-97 1.43eE-97 9.579E-98 7.212E-88 5.746E-88 4.725E-08 3.996E-88 3.427E-e8 2.992E-98 N
2.3e6E-96 7.316E-97 4.153E-97 2.984E-97 1.844E-87 1.356E-87 1.068E-97 8.745E-88 7.356E-68 6.314E-98 5.587E-88 NNE 3.740E-66 1.177E-46 6.571E-97 4.597E-87 2.936E-07 2.17eE-87 1.718E-07 1.414E-67 1.196E-87 1.032E-97 9.051E-98 i
HE 4.196E-06 1.264E-86 6.955E-87 4.964E-37 3.216E-87 2.424E-97 1.948E-e7 1.62eE-87 1.381E-97 1.2eeE-87 1.857E-e7 ENE 3.676E-96 9.84eE-67 6.SeeE-87 4.466E-87 3.932E-87 2.288E-87 1.826E-87 1.5e8E-67 1.277E-97 1.183E-87 9.666E-88 E
3.785E-96 1.239E-96 7.358E-87 5.285E-e7 3.422E-97 2.511E-87 1.968E-67 1.685E-e7 1.346E-e7 1.154E-e7 1.ee6E-87 i
ESE 4.867E-96 1.589E-96 8.795E-97 5.94X-47 3.53 tE 2.465E-97 1.869E-87 1.489E-87 1.226E-67 1.035E-97 8.909E-68 i
SE 2.115E-96 7.99X-47 3.99eE-67 2.72eE-07 1.631E-87 1.142E-e7 8.649E-68 6.875E-08 5.65eE-e8 4.759E-e8 4.986E-68 SSE 1.222E-96 4.198E-97 2.284E-87 1.568E-97 9.588E-88 8.811E-88 5.213E-98 4.172E-98 3.444E-68 2.911E-88 2.585E-98 ANNUAL AVERAGE CHI /O (SEC/WETER CUBED)
DISTANCE IN WILES t
sEARIHo 5.eee 7.5ee is.eee 15.ese 2e.ees 25.ees 3e.eee 35.ees 4e.eee 45.eee Se.coe S
1.722E-e8 1.914E-68 6.888E-99 3.959E-99 2.664E-99 1.953E-89 1.512E-99 1.215E-99 1.e64E-89 8.475E-te 7.274E-te SSW 1.534E-98 9.297E-99 6.32=E-99 3.686E-09 2.497E-89 1.837E-69 1.426E-49 1.148E-99 9.494E-te 8.819E-10 6.885E-18 SW 1.619E-98 9.764E-99 6.722E-99 3.918E-89 2.654E-69 1.953E-09 1.515E-99 1.219E-49 1.898E-99 8.512E-18 7.305E-18 l
WSW 2.530E-98 1.498E-98 1.821E-88 5.871E-49 3.545E-49 2.886E-99 2.23eE-49 1.789E-99 1.475E-99 1.243E-49 1.965E-99 W
2.763E-88 1.842E-98 1.125E-98 6.553E-99 4.449E-09 3.285E-49 2.558E-89 2.066E-69 1.715E-99 1.453E-09 1.251E-99 WNW 1.710E-96 1.042E-96 7.241E-99 4.283E-09 2.933E-99 2.177E-99 1.741E-89 1.377E-99 1.144E-69 9.783E-19 8.36eE-10 Nd 2.249E-98 1.385E-98 9.67eE-99 5.748E-99 3.943E-99 2.929E-89 2.29eE-89 1.856E-09 1.543E-99 1.399E-89 1.128E-89 j
NNW 2.645E-68 1.623E-98 1.135E-98 6.775E-89 4.C3E-99 3.479E-99 2.727E-99 2.214E-49 1.844E-99 1.566E-99 1.351E-99 N
4.867E-98 2.990E-98 2.e97E-48 1.268E-88 8.733E-09 8.543E-89 5.1520-09 4.199E-49 3.51eE-89 2.991E-99 2.589E-99 NNE 8.439E-98 5.946E-98 3.595E-98 2.298E-68 1.553E-98 1.176E-98 9.341E-89 7.663E-49 6.441E-89 5.514E-99 4.791E-89 NE 9.429E-98 6.ee6E-88 4.310E-48 2.880E-98 1.896E-98 1.442E-88 1.14eE-98 9.441E-99 7.949E-89 6.815E-99 5.928E-99 ENE 8.584E-ee 5.300E-98 3.826E-98 2.341E-88 1.641E-88 1.239E-98 9.818E-99 8.839E-99 6.745E-09 5.765E-49 5.ee2E-ee E
8.889E-88 5.479E-e8 3.858E-98 2.333E-88 1.824E-48 1.221E-te 9.637E-49 7.87eE-99 6.Se9E-49 5.823E-49 4.872E-89 ESE 7.789E-98 4.625E-88 3.182E-48 1.871E-98 1.281E-88 9.529E-99 7.466E-99 6.963E-99 5.953E-99 4.36tE-e9 3.717E-eg SE 3.564E-68 2.996E-98 1.431E-98 8.315E-99 5.652E-99 4.178E-99 3.257E-99 2.635E-99 2.189E-99 1.857E-99 1.661E-99 SSE 2.189E-96 1.292E-98 8.822E-99 5.118E-99 3.469E-89 2.558E-99 1.990E-e9 1.se6E-49 1.332E-99 1.128E-89 9.714E-te CHI /Q (SEC/WETER CUBED) FOR EACS4 SECMENT SEGMENT BOUNDARIES IN WILES DIRECTION
.5-1 1-2 2-3 3-4 4-5 5-10 to-20 2e-39 30-4e 49-58 FROM SITE S
1.81eE-87 7.153E-68 4.9 M -88 2.70eE-98 1.972E-88 1.027E-88 4.934E-99 1.966E-99 1.219E-69 8.494E-te SSW 1.268E-07 5.86eE-88 3.4414-?8 2.355E-98 1.746E-98 9.291E-99 3.745E-99 1.84 9E-99 1.152E-99 8 e37-te SW 1.196E-87 5.892E-88 3.53 U-94 2.46eE-88 1.838E-98 9.841E-89 3.98eE-99 1.965E-69 1.223E-99 8.530E-18 WSW 2.847E-97 9.770E-e8 5.75
- 98 3.920E-86 2.888E-08 1.515E-ee
- 5. 978E-99 2.996E-89 1.795E-89 1.246E-e9 W
2.647E-87 1.144E-97 6.481 be8 4.392E-98 3.157E-98 1.661E-88 6.662E-89 3.395E-89 2.873C-e9 1.456E-89 WNW 1.378E-87 6.259E-98 3.719t. 88 2.585E-98 1.937E-98 1.e49E-98 4.341E-49 2.188E-99 1.281E-89 9.721E-te NW 1.662E-97 7.675E-08 4.723E.*
3.35eE-68 2.538E-96 1.391E-88 5.817E-89 2.944E-69 1.831E-49 1.311E-49 NNW 2.926E-97 9.575E-98 5.726E-08 3.984C-98 2.992E-98 1.633E-08 6.855E-99 3.496E-89
- 2. 2~ eE-09 1.569E-69 N
4.381E-e7 1.863E-87 1.968E-87
, 356E-88 5.599E-98 3.818E-98 1.274E-88 6.571E-69 4.299E-89 2.996E-99 NNE 6.849E-87 2.965E-97 1.717E-87 1.196E-97 9.954E-88 5.e66E-88 2.226E-98 1.189E-88 7.677E-69 5.521E-99 NC 7.368E-07 3.239E-07 1.944E-87 1.389E-87 1.057E-87 6.016E-98 2.696E-08 1.446E-05 9.456E-09 6.823E-69 iNE 6.171E-87 3.82eE-97 1.822E-07 1.276E-87 9.668E-68 5.461E-98 2.36eE-08 1.243E-e8 8.054E-09 5.773E-99 l
E 7.551E-07 3.431E-67 1.968E-07 1.347E-07 1.ee6E-07 5.516E-08 2.357E-08 1.226E-OS
- 7. 88 7E-49 5.631E-09 ESE 9.194E-07 3.593E-07' 1.876E-87 1.228E-87 8.922E-e8 4.687E-e8 1.900E-08 9.58eE-09 6.08et-09 4.308E-09 SE 4.115E-07 1.655E-67
- 8. 67 7E-08 5.661E-08 4.692E-88 2.127E-e8 8.463E-09 4.203E-09 2.643E-e9 1.e61E-09 j
SSE 2.371E-87 9.788E-08 5.222E-88 3.449E-68 2.508E-08 1.3e9E-08 5.208E-09 2.573E-09 1.611E-89 1.131E-09 Y
0 9
ee809e9999999990 0*
tt110t0060e09e01 0 - - -
8888888888888888 ee08e0899999999e 5 EEEEEEEEEEEEEEEE 0e060e689ee8eeee tt11t1199884480t 4927e56270e11772 0
0 s - - - -
6 7654956121985145 e EEEEEEEEEEEEEEEE e EEEEEEEEEEEEEEEE 4
2 1 8 6.e.7 0 3 4 7 9 1 8 1 3 1 0
5 1914142788788357 e.
1562389094889412 8122982113784719 3551236399199755 6669171124554318 7
4 7565662678268341 e 3282361100241619 S
2 1112212247988732 5558969124544216 0e99999999999999 s
8888888888787888 00ee9e9999999990 1t100800009e0006 00ee8848e0008eee 11tt8t9e98899801 0 - - - -
3 e
0 4
EEEEEEEEEEEEEEEE e EEEEEEEEEEEEEEEE 0 EEEEEEEEEEEEEEEE 6833854657752621 e.
6115513936518655 0
4922875e"6675248 0 5476681582598548 8673344e36531266 6543846120874143 3 1984515845217491 4 9 7 8 9 1 9 5.e.4 9 0 9 0 6 0 4 5 2 1 8 6.e.7 9 3 4 7 9 1 8 1 3 1 4
989111113687641*
1112312358191842 6669171124554318 88888888P7777788 0ee99e9999999990 eeee49e8e0e8098e 1tt88t9090069481 9999999999588999 e
7, 69900900ee0e8890 e EEEEEEEEEEEEEEEE EEEEEEEEEEEEEEEE 0 - - - -
5 e427623482832985 9 3166933195e9e747 3 EEEEEEEEEEEr EEE 6796176154159283 62e4835438637796 333946B49633135e 3 3 0 1 4 7 2 9 5 3.e.2 1 1 6 7 9 0
43.t1212584996656 8 1600461228505553 2 5463574939219119 4
2223322361111142 7781191125665319 1112212259111731 8888888887777788 0ee9999999999999 06ee90e9698e4996 1tt4948869494499 e
0 e EEEEEEEEEEEEEEEE 0 EEEEEEEEEEEEEEEE 9999999988888899 r.
4247292367256e15 0 75773292824e4356 8694090980ee0e00 6917008893362678 1139591592597437 8
3 8461575152434285 5 1983515835217491 2 EEEEEEEEEEEEEEEE 3
43845154873e7885 2224423471111153 9891111136878411 6 3629085948392696 2039358768390450 1
8883888887777788 9999999999999999 S
e8e90e9888094688 89949699999e9490 333;534511222164 R
0 0
O 0 EEEEEEEEEEEEEEEE 0 EEEEEEEEEEEEEEEE C
5 4e69184478686685 0
6673756981812141 T
7785182828255941 4125466762947117 9998898838888888 A
2 5811832135767545 8 1127938219972544 0669060060e00e00 F
3 S
3335534591111174 1111111247988521 E8 EEEEEEEEEEEEEEEE T
L1 1554?968653e4922 N
G888888877777788 9999999999888999 I -
3669839034420737 E
e088e889068898ee 89988e9949800990 W5 6952391453288770 W S0 S0 T E0 EEEEEEEEEEEEEEEE E0 EEEEEEEEEEEEEEEE N
8781181124544311 S L0 359575711353181e L0 9219555911996494 I
U 3198773491585225 9598259985594831 I
I J W2 6995212419192199 W5 5 4 5 2 5 7 3 9 3 9 2 0.e.119 S
D A N 4336745611222295 N
1112212259111731 I
2 E
8888888858888888 9e080ee0000e00e0 I
I R
N 5888788877777778 999999999388899e A5 EEEEEEEEEEEEEEEE I
E 98e0889e98880888 E
e989699e969e099e D-3e164528017e5621 A C0 - - - - -
C9 l - - - - -
N4 0222982124795821 1
R N0 EEEEEEEEEEEEEEEE N9 EEEEEEEEEEEEEEEE U
7565662678268341 9
R A5 6274959892771129 A9 9927425253921868 O
9 E T 8754e72828668834 T
7986684191359793 B
1112212247988732 1
T S1 3 2 2 8.G.5 8 5 6 6 8 7 8.e.4 4 S8 8911432913643628 I2 T
I
)
D 6558156812223318 D
2123323371111942 N
T E
8888888887777788 N
L 7887787777777777 9999999988888899 W
08e0090000000000 E
A 0e88988688449889 888880888ee8099e G
V I
0 0 - - - - - -
E4 EEEEEEEEEEEEEEEE C
0 EEEEEEEEEEEEEEEE 0 EEEEEEEEEEEEEEEE S-2407919392733293 H
E 0 1e62798879594928 0 7255411239614855 3 6796175154159394 T
P 0792071888978729 5e6992813617e347 U
S 1
0963640251397243 5
- 1. e. 2 715 7 7 8 8 3 8. e. 4 4 9 3 9 1 4 7 2 9 5 3.e.2 1 1 0 7 9 O
1 2223322361111142 S
G 1771181124444521 3334534511222163
(
N I
7777777777777777 9999999988888889 E
S 90888089e669e4ee 8899446949890e88 8888888887777788 f
R t
0 - - - - -
- - - - - - ~ - - -
0 - - - - - -
e800000e00000000 U
5 EEEEEEEEEEEEEEEE 0 EEEEEEEEEEEEEEEE S NN 7 5382427435864315 0 83537979424661e5 T 3 EEEEEEEEEEEEEEEE O OO 1049893732788995 5814568846493145 N 3447205237346376 L
II
)0 4188314779246859
)8 6275191879733516 E 2 7674109920255872 C TT D D1 W
5611632035767645 N AA E 1111211135656732 E
5558968913333217 C E LL B B
E 3335534591111174 UU U 7777777776676677 U
99988988888s6868 S R CC C 88888e8e8e04ee88 C
88e9e86ee48e9e89 O RR 0
0 - - - - - - -
- H T
II R0 EEEEEEEEEEEEEEEE R0 EEEEEEEEEEEEEEEE C 88887888r7777778 CDCC E5 4173743541279686 E5 6516198954177924 A
e680868eee0009e0 AEEE T 6183198448663546 T
9127658912396185 E ETRR E8 4 9 7 8 1 1 5.e.7.e.1 0 1 4 5 7 E7 4842381353277770 2 EEEEEEEEECEEEEEE RE W
W R -
389378567105e366 LNN /
2113422361191163
/
8781181124544311 O 1
1631196843959456 PII C
C F
4228958566870145 EEAA E 7777677766666666 E
8888888888888888 SDRR S 90868e889989ee48 S
8e988e9488894989
)
6558156812223318 A RR (8 (W EEEEEEEEEEEEEEEE
- D E EE 5 EEEEEEEEEEEEEEEE E
L TT O2 8056e49156680258 O
891039162390861e B E
/. 92226786849191e5
/. 7220486854509663 U 7777777777777777 a
R.N N Ie 2 8 4 9 2 5 2 5 1 5 8 9 5 6.e.1 I5 4342349319277498 C 88e00000000ee000 YEE H H
EAPP C 7558168923323421 DCOC
~
C 1112211246877621 R 1
EEEEEEEEEEEEEEEE E
4782725043966993 OE E
E T
5 6486940480258014 WDRR G G
E 4108325882668271
- OO A A
W DYFF R R
/
1111211136656832
. O EA E
E C
xDDD V VG I
W0TT O SWWWWWWWNEEEEEEE SWWWWWWWNEEEEEEE
(
IISWWWWWWWNEEEEEEE I
$SS NNN MNN SSS TS SSS NNN NNN SSS
- 0. E E AC S W W N N E E S AA S W W N N E E S Q C S W W N N E E S RR UE UE
/ EM S8RR NS NB I
RO C OO N N
H IR L CC A A
C DF 1i
392700,,90 0
LCS - WIXED-WODE RELEASE REACTOR ENCLOSURE (SOUTH VENT) 1991 CORRECTED FOR OPEN TERRAIN RECIRCULATION CORRECTED FOR OPEN TERRAIN RECIRCULATION USINC SPECIAL TERRAIN ADJUSTWENT FACTORS RELATIVE DEPOSITION PER UNIT AREA (W..-2) AT FIXED POINTS SY DOWNWIND SECTORS DIRECTION DIST ANCES IN WILES FROM SITE 0.25 0.50 9.75 1.00 1.56 2.e0 2.50 3.e0 3.50 4.00 4.50 S
7.389E-09 2.767E-09 1.562E-09 1.055E-99 5.807E-10 3.819E-te 2.737E-te 2.068E-te 1.62eE-19 1.302E-te 1.e69E-t e SSW 4.285E-09 1.639E-09 9.525E-te 6.641E-16 3.776E-te 2.541E-te 1.849E-te 1.411E-10 1.112E-18 8.979E-11 7.386E-11 SW 3.522E-09 1.357E-09 8.055E-te 5.761E-10 3.363E-19 2.301E-18 1.692E-te 1.299E-10 1.02EE-10 8.321E-11 6.854E-11 WSW 6.990E-09 7.615E-09 1.527E-09 1.08eE-09 6.273E-te 4.265E-te 3.123E-te 2.392E-10 1.8890-18 1.526E-10 1.256E-te W
1.065E-08 3.873E-e9 2.156E-89 1.444E-09 7.921E-10 5.182E-te 3.70eE-te 2.787E-te 2.178E-te 1.74BE-te 1.432E-19 WNW 4.778E-89 1.776E-89 1.312E-49 6.952E-10 3. 916E-16 2.612E-19 1.889E-te 1.436E-te 1.12BE-te 9.090E-11 7.466E-t t NW
- 4. 511E-09 1.717E-89 9.971E-le 6.95eE-10 3.951E-te 2.655E-te 1.933E-18 1.475E-10 1.162E-18 9.387E-11 7.7165-11 NNW 5.840E-99 2.359E-89 1.388E-09 9.459E-19 5.270E-10 3.397E-te 2.389E-te 1.782E-10 1.384E-te 1.187E-19 9.063E-11 N
1.289E-88 4.483E-99 2.44eE-e9 1.623E-89 8.811E-18 5.734E-te 4.98eE-19 3.067E-10 2.393E-10 1.920E-te 1.572E-te NNE 2.062E-88 8.810E-99 4.378E-89 2.825E-89 1.491E-09 9.36DE-18 6.491E-19 4.792E-10 3.697E-16 2.945E-te 2.4e5E-te NE 1.859E-98 7.517E-89 4.88eE-89 2.623E-99 1.379E-99 8.715E-te 6.e7eE-te 4.502E-te 3.485E-10 2.785E-te 2.2eeE-18 ENE 1.621E-88 6.597E-09 3.559E-e9 2.362E-99 1.216E-09 7.764E-te 5.377E-te 3.992E-10 3.093E-te 2.473E-19 2.024E-10 E
2.934E-88 1.189E-98 5.983E-99 3.822E-99 1.995E-89 1.246E-e9 8.661E-te 6.332E-10 4.874E-18 3.877E-18 3.162E-te ESE 4.874E-e8 1.730E-e8 9.214E-99 5.858E-e9 3.914E-09 t.883E-99 1.3e2E-89 9.596E-10 7.385E-te 5.873E-18 4.785E-18 SE 2.458E-08 8.851E-09 4.763E-89 3.047E-99 1.580E-99 9.93eE-te 6.895E-10 5.997E-te 3.934E-te 3.133E-18 2.556E-10 SSE 1.251E-98 4.493E-89 2.440E-99 1.586E-99 8.487E-te 5.365E-te 3.766E-18 2.864E-18 2.174E-te 1.736E-te 1.419E-te DIRECTION DISTANCES IN WILES FROW SITE 5.00 7.50 10.06 15.e0 20.00 25.ee 38.00 35.00 40.ee 45.00 50.0e S
8.915E-11 4.532E-11 2.864E-11 1.481E-11 9.184E-12 6.396E-12 4.78eE-12 3.668E-12 2.931E-12 2.40eE-12 2.ee5E-12 SSW 6.169E-11 3.154E-11 1.995E-11 1.034E-11 6.426E-12 4.48EE-12 3.337E-12 2.593E-12 2.081E-12 1.711E-12 1.437E-12 SW 5.727E-11 2.935E-11 1.856E-11 9.614E-12 5.972E-12 4.165E-12 3.093E-12 2.402E-12 1.927E-12 1.584E-12 1.331E-12 WSW 1.048E-te 5.352E-11 3.378E-11 1.743E-11 1.079E-11 7.476E-12 5.52eE-12 4.264E-12 3.464E-12 2.787E-12 2.331E-12 W
1.193E-10 6.035E-11 3.605E-11 1.957E-11 1.298E-11 8.349E-12 6.157E-12 4.753E-12 3.795E-12 3.198E-12 2.5e2E-12 WNW 6.229E-11 3.171E-11 2.ee2E-11 1.034E-11 6.406E-12 4.455E-12 3.307E-12 2.573E-12 2.871E-12 1.7e9E-12 1.443E-12 6.444E-11 3.293E-11 2.082E-11 1.078E-11 6.700E-12 4.685E-12 3.495E-12 2.731E-12 2.208E-12 1.829E-12 1.551E-12 NW NNW 7.556E-11 3.777E-11 2.342E-11 1.186E-11 7.325E-12 5.082E-12 3.797E-12 2.990E-12 2.446E-12 2.853E-12 1.770E-12 N
1.31eE-10 6.627E-11 4.184E-11 2.156E-11 1.334E-11 9.278E-12 6.999E-12 5.494E-12 4.381E-12 3.643E-12 3.106E-12 NNE 2.Be4E-18 1.001E-te 6.26TE-11 3.227E-11 2.018E-11 1.418E-11 1.077E-11 8.622E-12 7.184E-12 6.123E-12 5.359E-12 NE 1.903E-te 9.591E-11 6.854E-11 3.172E-11 2.012E-11 1.441E-11 1.115E-11 9.073E-12 7.679E-12 6.62EE-12 5.868E-12 ENE 1.689E-13 8.516E-11 5.371E-11 2.804E-11 1.771E-11 1.262E-11 9.69tE-12 7.82eE-12 6.556E-12 5.611E-12 4.924E-12 E
2.631E-te 1.311E-10 8.22eE-11 4.226E-11 2.629E-11 1.833E-11 1.375E-11 1.984E-11 8.879E-12 7.448E-12 6.403E-12 1
ESE 3.97CE-te 1.984E-te 1.25eE-18 6.487E-11 3.937E-11 2.711E-11 1.993E-11 1.534E-11 1.222E-15 ' 992E-12 8.353E-12 SE 2.12SE-te 1.065E-te 6.716E-11 3.452E-11 2.127E-11 1.471E-11 1.884E-11 8.354E-12 6.653E-ti. 432E-12 4.530E-12 SSE 1.181E-10 5.93eE-11 3.737E-11 1.919E-11 1.182E-11 8.146E-12 5.99eE-12 4.688E-12 3.667E-12 2.992E-12 2.495E-12 e.......................
RELATIVE DEPOSITION PER UNIT AREA (Wee-2) BY DOWNWIND SECTORS SEGMENT SOUNDARIES IN MILES DIRECTION
.5-1 1-2 2-3 3-4 4-5 5-19 19-26 29-3e 30-40 40-50 FROW SITE S
1.604E-09 5.977E-18 2.758E-19 1.627E-te 1.e72E-10 4.765E-11 1.538E-11 6.477E-12 3.693E-12 2.411E-12 SSW 9.769E-te 3.864E-18 1.858E-te 1.116E-te 7.407E-11 3.309E-11 1.874E-11 4.545E-12 2.610E-12 1.719E-12 SW 8.26eE-te 3.424E-te 1.697E-te 1.031E-18 6.871E-11 3.076E-11 9.984E-12 4.218E-12 2.418E-12 1.592E-12 CSW 1.570E-09 6.388E-10 3.135E-te 1.895E-10 1.259E-te 5.615E-11 1.811E-11 7.57BE-12 4.295E-12 2.801E-12 W
2.221E-09 8.153E-te 3.730E-10 2.1BBE-te 1.437E-te 6.354E-11 2.035E-11 8.467E-12 4.789E-12 3.124E-12 WNW 1.e41E-09 4.013E-19 1.90eE-te 1.1330-18 7.489E-11 3.331E-11 1.074E-11 4.516E-12 2.591E-12 1.718E-12 NW 1.023E-09 4.043E-te 1.943E-10 1.166E-19 7.739E-11 3.455E-11 1.12eE-11 4.746E-12 2.75eE-12 1.838E-12 NNW 1.407E-09 5.368E-te 2.415E-10 1.392E-10 9.teeE-11 3.979E-11 1.241E-11 5.166E-12 3.e14E-12 2.065E-12 N
2.513E-09 9.091E-10 4.116E-te 2.4e5E-te 1.57BE-te 6.98eC-11 2.241E-11 9.413E-12 5.444E
.2 3.663E-12 NNE 4.495E-09 1.541E-09 6.579E-10 3.723E-te 2.417E-te 1.057E-18 3.365E-11 1.442E-11 8.688E-12 6.15:E-12 NE 4.196E-09 1.430E-09 6.148E-te 3.389E-te 2.29CE-10 1.012E-10 3.297E-11 1.463E-11 9.134E-12 6.658E-12 ENE 3.655E-09 1.259E-09 5.444E-10 3.114E-te 2.033E-18 8.98eE-11 2.915E-11 1.281E-11
- 7. 873E-12 5.637E-12 E
6.157E-09 2.068E-09 8.723E-te 4.913E-10 3.177E-18 1.387E-10 4.484E-11 1.862E-11 1.e92E-11 7.485E-12 ESE 9.515E-09 3.142E-09 1.320E-09 7.442E-te 4.8e8E-te
- 2. tete-18 6.664E-11 2.751E-11 1.546E-11 1.ee5E-11 SE
- 4. 909E-09 1.645E-09 6.985E-te 3.961E-te 2.567E-te 1.126E-te 3.589E-11 1.491E-11
- 8. 417E-12 5.46eE-12 SSE 2.516E-09 8.711E-10 3.888E-te 2.187E-10 1.425E-10 6.261E-11 1.995E-11 8.262E-12 4.644E-12 3.eeBE-12 VENT AND BUILDING PARAMETERS:
RELEASE HEIGHT (WETERS) 61.0e REP. WINO HEICHT (WETERS) 53.3 DIAuETER (WETERS)
'3.44 BUILDING HEIGHT (uETERS) 61.8 t
O
(
39270
'/90 LCS - WIXED-WODE RELEASE REACTOR ENCLOSURE (SOUTH YENT) 1991 CORRECTED FOR OPEN TERRAIN RECIRCULATION SPECIFIC POINTS OF INTEREST RELEASE TYPE OF DIRECTION DISTANCE X/Q r/Q y/Q D/Q ID LOCATION (WILES) (WETERS) (SEC/CUU.WETER) (SEC/ COB.WETER) (SEC/Ci>B.WETER) (PER SQ.WETER)
NO CECAY 2.269 DAY DECAY 6.000 DAY DECAY UNN PLETED UTEPtETED DEPLETED S
SIIE BOUNDARY S
e.81 1311.
1.412E-07 1.4e9E-07 1.274E-07
- 1. 395E-0 9 S
SITE BOUNDARY
$$W e.49 793.
2.121E-07 2.118E-07 1.948E-07 1.672E-89 S
SITE BOUNDARY SW 0.61 975.
1.512E-07 1.589E-07 1.374E-07 1.05eE-09 S
SITE BOUNDARY WSW 0.55 884 2.924E-07
- 2. 919E-87
- 2. 668E-07 2.294E-09 S
SITE BOUNDARY W
e.57 914 3.751E-e7 3.745E-07 3.411E-07 3.211E-e9 S
SITE BOUNDARY WNW e.55 884 2.013E-07 2.009E-07 1.835E-07 1.553E-09 5
SITE BOUNDARY NW 0.59 945.
2.242E-87 2.237E-e7 2.035E-07 1.376E-e9 SITE BOUNDARY NNW 0.68 1997 2.211E-07 2.2e6E-07 2.eeeE-e7 1.576E-09 S
SITE BOUNDARY N
0.63 1986.
5.343E-97 5.331E-87 4.825E-87 3.182E-e9 S
SITE BOUNDARY NNE e.55 884.
1.e28E-06 1.e25E-e6 9.366E-07 6.987E-e9 SITE BOUNDARY HE e.53 853.
1.157E-06 1.154E-06 1.857E-06 6.909E-69 S
SITE BOUNDVtY ENE 9.72 1158.
6.384E-07 6.285E-97 5.747E-07 3.789E-99 5
SITE BOUNDARY E
6.72 1158.
7.751E-07 7.732E-87 7.037E-07 6.379E-09 S
SITE BOUNDARY ESE e.51 823.
1.538E-96 1.536E-86 1.485E-e6 1.67eE-88 5
SITE BOUNDARY SE e.76 1219.
- 3. 939E-67 3.932E-e7 3.537E-07 4.689E-09 S
SITE BOUNDARY SSE e.78 1250.
2.178E-87 2.174E-07 1.954E-97 2.314E-09 5
RAILROAD TRACKS S
6.19 300.
1.274E-e6 1.274E-e6 1.228E-96 1.093E-e8 RAILROAD TRACKS SSW 0.14 225.
1.681E-06 1.68eE-e6
- 1. 623E~-06
- 9. 272E-09 S
RAIL';OAD TRACKS SW 0.14 225.
1.588E-06 1.587E-06 1.533E-06 7.633E-99 5
RAILROAD TRACKS WSW e.14 225.
2.643E-e6 2.642E-e6 2.552E-e6 1.552E-08 S
RAILROAD TRACKS W
0.14 225.
3.711E-06 3.71eE-06 3.584E-06 2.392E-e8 S
RAILROAD TRACKS WNW 0.21 345.
9.071E-07 9.864E-e7 8.639E-97 5.871E-09 S
RAILROAD TRACKS NW 8.28 450.
7.178E-e7 7.17eE-07 6.764E-07 3.862E-09 5
. INF0FJ8ATION CTR ESE e.55 884 1.385E-06 1.383E-06 1.261E-66 1.496E-98 5
FRICKS LOCK WSW 0.28 450.
7.745E-07 7.739E-07 7.297E-e7 5.964E-89 VENT AND BUILDING PARAMETECS:
RELEASE HEIGHT IMETERSl 61.00 REP. WIND HEIGHT CMETERS 53.3 DIAWETER l'WETERSS 3.44 BUILDING HEIGHT I METERS 61.0 EXIT VELOCITY (W/SEC j 7.32 BLOG. WIN.CRS.SEC. AREA (CAL /SEC) )
SQ. WET RS 4596.0 HEAT EMISSICN RATE 1,
9.e AT THE RELEASE HEIGHT:
AT THE WEASURED WIND HEIGHT (
9.1 WETERS)
VENT RELEASE WODE WIND SPEED (WETERS/SEC)
VENT RELEASE WODE WIND SPEED (WETERS/SEC)
WIND SPEF3 (WETERS/SEC)
STABLE CONDITIONS URSTABLEt EUTRAL CONDITIONS ELEVATED LESS THAN 1.464 ELEVATED LESS THAN e.605 LESS THAN e.941 WIXED BETWEEN
.1.464 AND 7.328 WIXED BETWEEN 0.685 AND 3.025 GETwEEN e.941 AND 4.7e5 GROUND LEVEL ABOVE 7.328 CROUND LEVEL ABOVE 3.825 ABOVE 4.705 l
Q g
39270C90 LCS - WIXED-WODE RELEASE TURBINE ENCLOSURE (NORTH VENT) 1991 2.260 DAY DECAY.
UNDEPLETED CORRECTED FOR CPEN TERRAIN PECIRCUL ATION CORRECTED FOR OPEN TERRAIN RECIRCULATION USING SPECI AL 1ERRAth ADJUSTWENT FACTORS ANNUAL AVERAGE CHI /O (SEC/WETER CUBED)
DISTANCE IN WILES SECTOR 0.258 9.500 0.758 1.000 1.500 2.000 2.500 3.eee 3.500 4.ees 4.5e0 S
6.995E-07 2.416E-e7 1.374E-07 9.531E-08 5.97EE-08 4.37eE-ea 3.430E-08 2.881E-03 2.349E-08 2.e tee-08 1.746E-08 SSW 5.511E-07 1.85eE-07 1.052E-07 7.425E-08 4.817E-08 3.60BE-08 2.88eE-08 2.383E-e8 2.020E-08 1.744E-08 1.526E-e8 SW 5.208E-87 1.751E-87 1.ee6E-87 7.144E-08 4.724E-08 3.612E-98 2.931E-08 2.454E-98 2.098E-08 1.822E-e8 1.603E-08 WSW 8.620E-87 2.989E-87 1.729E-07 1.234E-07 8.899E-08 6.095E-98 4.869E-08 4.023E-08 3.462E-08 2.92BE-08 2.556E-e8 W
1.201E-96 4.e34E-87 2.249E-07 1.547E-87 9.593E-08 6.977E-08 5.468E-08 4.464E-08 3.74EE-05 3.299E-08 2.792E-08 WNW 6.249E-87 2.848E-87 1.14 9E-87 7.954E-88 5.944E-88 3.774E-08 3.936E-08 2.534E-08 2.166E-08 1.884E-08 1.66eE-08 NW 7.798E-87 2.499E-87 1.38SE-87 9.519E-08 6.e58E-08 4.617E-08 3.782E-98 3.202E-08 2.766E-08 2.425E-08 2.15eE-88 NNW 9.11eE-e7 2.947E-87 1.682E-67 1.192E-87 7.798E-08 5.991E-98 4.761E-08 3.974E-08 3.395E-88 2.95eE-e8 2.598E-08 N
2.862E-e6 6.585E-e7 3.626E-87 2.488E-87 1.546E-07 1.136E-87 9.814E-08 7.451E-05 6.325E-88 5.475E-e8 4.809E-08 MNE 3.359E-e6 1.e48E-06 5.74 9E-97 3.959E-87 2.479E-07 1.834E-07 1.462E-87 1.214E-87 1.034E-07 8.982E-08 7.918E-98 NE 3.684E-06 1.125E-06 6.e58E-87 4.17eE-87 2.673E-07 2.318E-07 1.635E-87 1.373E-87 1.181E-07 1.033E-07 9.161E-e8 ENE 2.759E-06 8.644E-87 4.967E-87 3.595E-07 2.429E-07 1.861E-07 1.518E-87 1.264E-07 1.982E-07 9.421E-98 8.318E-e8 E
3.411E-06 1.181E-66 6.283E-e7 4.428E-87 2.845E-07 2.196E-07 1.669E-07 1.374E-07 1.163E-07 1.e03E-97 8.792E-08 ESE 4.388E-e6 1.432E-e6 7.859E-07 5.26eE-07 3.993E-07 2.169E-97 1.644E-97 1.316E-87 1.89eE-07 9.246E-08 7.989E-08 SE 1.916E-86 6.404E-87 3.559E-87 2.49eE-07 1.426E-07 9.996E-08 7.618E-08 6.096E-08 5.e42E-e8 4.271E-88 3.684E-08 SSE 1.11eE-06 3.728E-87 2.943E-87 1.379E-07 8.278E-e8 5.874E-e8 4.522E-08 3.E48E-08 3.035E-08 2.583E-08 2.237E-08 ANNUAL AVERAGE CHI /O (SEC/WETER CUBED)
DISTANCE IN WILES BEARING 5.000 7.500 10.000 15.000 20.000 25.000 30.000 35.000 40.000 45.000 50.000 S
1.538E-08 9.273E-09 6.379E-09 3.713E-09 2.516E-09 1.851E-89 1.436E-09 1.157E-89 9.572E-te 8.088E-10 6.948E-te
$$W 1.353E-88 8.336E-89 5.812E-89 3.436E-09 ?.346E-99 1.735E-09 1.351E-09 1.09eE-09 9.037E-te 7.645E-10 6.573E-te 55 1.425E-08 8.842E-09 6.181E-09 3.658E-09 2.497E-09 1.846E-89 1.436E-09 1.159E-09 9.598E-10 8.115E-16 6.972E-te s.g 2.258E-e8 1.372E-88 9.467E-99 5.519E-09 3.733E-99 2.742E-09 2.124E-09 1.767E-89 1.410E-99 1.189E-89 1.82eE-89 W
2.461E-88 1.493E-08 1.934E-98 6.886E-09 4.154E-09 3.076E-69 2.400E-09 1.942E-09 1.614E-89 1.368E-09 1.179E-09 WNW 1.479E-08 9.287E-89 6.557E-99 3.941E-99 2.721E-09 2.030E-99 1.591E-89 1.291E-89 1.075E-69 9.134E-10 7.88eE-10 NW 1.925E-08 1.226E-68 8.717E-89 5.271E-09 3. 646E-09 2.722E-99 2.136E-99 1.734E-09 1.445E-99 1.227E-89 1.059E-09 NNW 2.315E-88 1.456E-88 1.932E-88 6.243E-89 4.333E-09 3.245E-89 2.552E-99 2.077E-89 1.733E-09 1.415E-09 1.275E-09
- 4 4.276E-08 2.681E-88 1. 401E-98 1.155E-98 8.848E-09 6.e52E-89 4.778E-99 3.992E-89 3.267E-89 2.788E-09 2.415E-09 NNE 7.066E-88 4.587E-88 3.240E-88 2.eleE-e8 1.422E-08 1.081E-98 8.618E-89 7.e81E-89 5.963E-89 5.114E-09 4.45eE-e9 NE 8.216E-88 5.326L-88 3.866E-98 2.426E-88 1.727E-08 1.319E-98 1.854E-98 8.691E-89 7.334E-e9 6.3eeE-89 5.489E-99 ENE 7.432E-98 4.756E-98 3.415E-68 2.118E-e8 1.495E-e8 1.135E-88 9.928E-89 7.416E-09 6.239E-89 5.345E-89 4.647E-09 E
7.897E-88 4.893E-08 3.478E-88 2.127E-88 1.49eE-88 1.126E-88 8.917E-09 7.382E-e9 6.129E-69 5.241E-99 4.549E-89 ESE 7.e19E-98 4.216E-86 2.921E-06 1.731E-98 1.191E-08 8.879E-09 6.971E-89 5.679E-89 4.734E-69 4.032E-09 3.488E-99 SE 3.228E-88 1.927E-88 1.326E-88 7.773E-09 5.309E-99 3.937E-89 3.876E-89 2.492E-09 2.874E-99 1.761E-89 1.52eE-69 SSE 1.965E-08 1.182E-98 6.153E-69 4.781E-89 3.258E-09 2.411E-09 1.88eE-89 1.52eE-89 1.26 3E-e9 1.0 71E-09 ' 9.226E-10 CHI /O (SEC/WETER CUBED) FOR EACH SEGMENT SEGMENT BOUND 4 RIES IN WILES DIRECTION
.5-1 1-2 2-3 3-4 4-5 5-te 10-20 20-3e 30-49 40-50 FROW SITE S
1.418E-e7 6.052E-88 3.429E-08 2.349E-88 1.747E-08 9.343E-09 3.773E-89 1.862E-09 1.161E-69 8.105E-te SSW 1.092E-07
- 4. 859E-68 2.875E-08 2.019E-08 1.526E-08 8.368E-09 3.48eE-09 1.744E-09 1.094E-09 7.66eE-19 SW 1.042E-07 4.768E-88 2.922E-88 2.995E-08 1.602E-08 8.86eE-89 3.703E-09 1.856E-09 1.162E-e9 8.131E-te WSW 1.787E-07 8.150E-08 4.858E-88 3.399E-08 2.556E-08 1.38eE-08 5.602E-09 2.759E-09 1.713E-09 1.192E-09 W
2.33JE-e7 9.736E-08
- 5. 4 6 9E-08 3.747E-08 2.793E-88 1.504E-08 6.173E-09 3.e93E-09 1.948E-99 1.371E-e9 WNW 1.191E-07 5.126E-08 3.032E-08 2.164E-08
- 1. 65 9E-08 9.296E-69 3.98eE-09 2.039E-e9 1.295E-09 9.15eE-18 NW 1.441E-07 6.186E-08 3.773E-08 2.761E-e8 2.14BE-08 1.224E-08 5.315E-09 2.734E-09 1.739E-69 1.229E-99 NNW 1.745E-87 7.87eE-88 4.75eE-08 3.391E-88 2.598E-08 1.458E-08 6.299E-99 3.258E-09 2.082E-89
- 1. 477E-09 N
3.76eE-07 1.573E-67 9.014E-08 6.323E-08 4.809E-08 2.688E-08 1.165E-08 6.075E-09 3.910E-09 2.792E-89 NNE 6.eetE-07 2.519E-07 1.462E-07 1.034E-87 7.918E-08 4.512E-08 2.022E-08 1.084E-68 7.092E-99 5.120E-99 NE 6.373E-87 2.715E-07 1.632E-87 1.18eE-07 9.158E-08 5.319E-08 2.435E-e8 1.322E-08 8.702E-09 6.306E-09 ENE 5.174E-07 2.*36E-07 1.5057-07 1.eBeE-07 8.317E-e8 4.752E-05 2.129E-08 1.138E-08 7.42BE-09 5.351E-09 E
6.510E-07 2.868E-07 1.668E-07 1.162E-07 8.795E-08 4.912E-08 2.144E-08 1.129E-08 7.316E-09 5.248E-09 ME-8.141E-07 3.160E-07 1.651E-07 1.092E-87 7.999E-08 4.261E-08 1.755E-08 8.923E-09 5.685E-09 4.039E-09 E
3.676E-07 1.453E-07
- 7. 64 3E- 08 5.049E-08 3.689E-08 1.949E-08 7.897E-09 3.958E-09 2.500E-09.
1.764E-e9 dSE 2.123E-87 8.435E-88 4.533E-08 3.038E-08 2.239E-08 1.193E-08 4.853E-09 2.424E-09 1.525E-09 1.073E-09
l O
CN b%
@@@@a@eeamomenec
(
I l I i e1 I i 6 8 4 4 1 4 0 t ecWeemememememme
@@@@@@@mmOpmmSOG O WWWWWWWWWWWWWWWW t
G@@@@@@@@@@@@@@@
- = * * *" * "l i*= @ @ @ @ tp @6 @@**
I
@ O m
- w en tD N N nD w @ O (D - N
'D l i t I t 4 6 4 4 4 4 4 4 0 0 4 l I lI i i i l l e 6 4 i
@ N w tD N P) e @ w ID O v @ N e m @
WWWWWWWWWWWWWWWW G WWWWWWWWWWWWWWWW w
eO N O N @ w en P) eO e N
- N N
- en to to O @ @ to N to ED
G. a tO N. G. M G N N r) C. ID. O. m. N. to.
b e e e e e e.
@ N O N N M N N @ w *= F) p G N N e
P) to M " to M W N to P) M N N v @ Pm W O tO @ om b e ** N g O y y N e= N e
bj O. P) w N. M. W. W. N. e* C. @. W. 40 40. @. eD.
W p @ tD. D. G. ra. tD. @. @. W. W.
C O O b e e m - - M e,".9 0.e.W.
40
---NN--N,..ebben-CN nN-e
@@@mmmmmmmmmmmmm a m m m e eD e m o m m m m m m e Ge@eo@oamemoaoa@
---@@@@@@@@e@@@@
@ tD @ @ @ @ @ @ @ @ @ @ tD @ @ @
- * ** @ * @ @ @ @ @ @ @ @ @ "l G i I I ea1 0 t eei6 4 4 4 4 "l
l i 0 4 4 4 4 1 eie6 eI a 4 i i i i i i i i i 4 i i l i uJWWWWWWWWWWWWWWW
@ WWWWWWWWWWWWWWWW 4 WWWWWWWWWWWWWWWW.
I N N " w ED P) N O m n G n m @ O N N @ m
- P)
- M cu tD w e - w to@tDM meom @ w OIDN M Pe p (D e=
- ED N e ed to m M *= N w ar) eD e O tr e M N tD e e M e= @ @ 0D
- M G IO tD N N W t0er)M M S w N O 9 m N Otolo M
- b. 0. t0 0 6. tD. **. tr) @ N. G. T. GD. 40. C. **.
@ @ d.N. @.Pl. @.N N P) C.h.tO.O.N.N.
N C e, P) w @ v N - @ o.gD.N N.10
- e e 40 g g @ w,= w += w Pg 4D N g to y p,.
y e e.
- = *= *= N N e= N N 9 b @ m W N P) N 40 0 40 @ e b a
- N W O T W N ** h m eD ID ED eD tD a0 m to eD N eD N 40 m 40
@ @ @ m m @ m m m m m e m sn m @
l
- * "t$ $ "l G @ @ @ @ @ @ @ @ "l
@@@@mmmmS@mem@@@
l t i l l et i l t t i l l l i 9
l i i e i l l el l i t i
@@@@@@@@@@@GG@@@
WWWWWWWWWWWWWWWW WWWWWWWWWWWWWWWW G
4 0 4 4 i eaet I ea4 e i4 en P) e C N e* ED w a a w to w M e @ @
e N P) @ @ @ @ *= "D G P) m N S) N N w @ N ED
- w e P)
WWWWWWWWWWWWWWLpW 9 tD en m N eD N cD P) tD M @ N N tD N e
O F) O O ** N EO tD t 6
dD O c N @ tO tD M N N N ED e *= w e P)
@ N. g) p N. O. 9. @. w. m. G. N. @. *=. N. O.
- @ N. S. N. tD. **eW 49. *=. 4. GO. N. T. O. N.
@ M M * @ m w
- w w @ v C N *= to N g
N v M eO *= M c N N O N * @ c N e to N e= w N M *= N N aO to *= @ ** O
- N b b b " " # *" " N O G O O P) ** #
- *= " N N ** N N 9 m * *= O (D N ea to eD ED eO eD e ID c ID N N N N N 10 0D
@@@@m@G#@AGGm@mm
@ @ @ @ @ @ @ @ @ M O G G @ @ ED 6 $ 1 1 1 4 6 4 4 6 e1 i 4 4 4 9
"0 "1 "0 0@ (P @#@ @ S S @ @ @ @tp @i t
? i e i l i i li WWWWWWWWWWWWWWWW
@ WWWWWANWWWWdWWWW emommmmopememmem m e N w @ e N o - N e e n tD e h G.
m O m ev e S M cD N eu-we
@ @ @ @ @ @ @ @ @ @ tD G @ @ @ @
w m N O t0 *= w @ P1 t(# G P) **
- eD e=
- P) N P) N P) " @ v G N e @ * **
4 4 4 4 0 6 4 ei4 4 4 0 4 4 4 F)
- @ *= O. IO. N. G. O W G N e* N P *= *=
40 h O P1 P) 4. @. 9. N.TN.)W W N.=.0D.*e N WWWWWWWWWWWWWWWW e..
e e e e e e e e M
e e a.
4
==tr) @ @ N O w w M m ED e - N v N N N N P) P) N N P) t0 *= *= *= * *= tf> P)
W W E ** *= e= **
- P) @ b tD W W *= e P) O @ @ N m v 40 9*= @ w
- GO N m
@ C " 40 9 N e P) 40 h w 10 C P) *= N
- =
to (O W e 80 m e ED eD N N N N Ps W eD m @ G S @ m G m O # 9 @ # # eB e
- * * * * * * * *
- e * * *
- e M
@ @ @ @ @ (D (D @ @ @ @ @ @ G @ @
P) N P) T T F) W O @
- N p ** ** tO P)
E ED e# 4 eieieI t 1 4 6 8 6 0 4 4 6 6 4 4 e4 0it 6 i 4 4 6 O
@ WWWWWWWWWWWWWWWW
@ WWWWWWWWWWWWWWWW N
eO O w on e en v h an *= N O O N D @ @
- O N M er) OID N P)tD m e w eD w N O
e
- * (D e= 0 m N e= *= N P en N m M e
@ eD O P* P) Ps v 9 W N N N ort eD G @
@ G S 80 eD S ID 10 m m 80 m 8) ED e @
(
N @ O tD P) N e F3 N EO N 9 M V F)er)m
@ @
- W W N N
- e M *= $ 9 *= N M 6
- e M
nrt i I 4 4 ei4 1 0 ei1 8 4 4 6 F) N N W v N M w N ** ** * ** e tD P)
- ** ** e * *
- N P) b O W h O N '*
WG WWWWWWWWWWWWWWWW 6
.J*=
b to w to fD m @ N w N N w M * (D N 2
m e m eD ED e to M O N N N N N M W maeOmaOmemmeSmaSS e=
0 g *= 9 5 en a O to tD N N N e g s) en W
3O E0 *'* tO '* N ID G N N C GO N N 9 O N 2 MG l 8 0 0 t i 4 eie t 4 4 4 4 i MS I eiit i l 4 4 4 4 6 i l l 6
- * * * * * * * * * * *
- a a +
P=
W tp WWWWWWWWWWWWWWWW W CD WWWWWWWWWWWWWWWW 2
N N N *
- b w *= N P) t t t M e @
M
.J G (D @ @ e M *= w e w N to 10 *= M N *=
.J G N @ C O P) S P) @ * *
- O G 5310 N D *= *
- =
e m N N S N ep p) CD (D N N N en 9 m
- 1 2N N N @ N N P) M P) N N v @ P) e e *=
== +
Q
- 40. **. N. T. ". P) G. N. ID. tD. N. @. G) 40 40. @.
3O v P1 C *= M. 40.N b @ *= ** G.W. 40. @.C.M N
l 8
e e e e e e...
W soto80 mtoqDtoCD1000c0CDE 4 2 l
\\
F) PD F) W W P) W O O ** * * * *= C O 2
- * ** N N *= N N 9 G e* *= O W N==
ED @ @ @ @ @ @ @ @ @ @ @ @D 10 E)tD
- =
2 to 2 00101010 00ED N N N N N P* N eD m m a m m m m m a to ED e eD @ m m
<O WWWWWWWWWWWWWWWW K
6 4 6 4 6 8 8 6 I l l 4 e i ea W
W
@ (D @ @ @ @ @ @ @ ED @ @ (D @ @ @
C1 M M e to tD a0
- w to 10 CD C @ w @ to
==
4 U ED e 4 4 4 4 4 4 4 4 4 4 i eiet O@
l 6 6 6 i l l 6 4 4 4 4 4 i 4 6 2e O Pl
- N P) v EO N. **etD N G N E 2@ WWWWWWWWWWWWWWWW 2& WWWWWWWWWWWWWWWW D
10 5 m
CL 4O O to e N e r) m P) M w N
- N N e N 4, @
G N ED M O M O 9 o= en v S to @ cD N O
10 @ v P I a
W N *
(D (D
- N w 40 P) P) eO ED to G F) e0 w
- N *
- * * * *
- e e *
- e * - e N to en @ w w @ O N G m N N an en e gb
- = ** ** N N '= *= N W 4D C N N IO M **
P=
M*
P) N. N. N T. T. F) M M. *. P) *= O. tO. N. N..M.e @ G. E) (D. G. N. N. G. ED. O. N. W.P) N. @. @. w.
.=
N N
d="*
Q O e T b C W O W " N N N N N ** N Q
- = *= N P) M N P) P) W *= *= *= ** @ W N 2W CWWWWCCemebebemm 2
.J ED ED E) N N EO eD P* N N N *% N N N N O m e e m a m m m eD e m 80 eD e m 2
@ (D S tD (D cD @ @ @ @ @ @ O cp @ @
W
(
@ @ @ @ tD G @ @ @ @ @ @ @ @ @ @
tD@@@@@@@@@@@@@@@
O 4 4 4 6 I e4 i eI a6 ( 4 ie 4 1 1 4 ei4 4 4 4 4 4 4 et i 6 6 6 6 6 6 6 4 ei1 ei4 4 i W9 WWWWWWWWWWWWWWWW l
O WWWWWWWWWWWWWWWW
@ WWWWWWWWWWWWWWWW to 4 P4 W N O N O S)tD N
- C M P) N e @
2 W
N e d en C P) m eO eG eO e ED eO N G w G m P) P) N M w w en c h e w ep w r)
P) w e en tD N cD== cD P) tD M m N e 40 6 P=
(L N w 9 @ N M en U @ ** ** w Ps u) P4 N ep @ eO *= P) W 9 m (B @ m ED N P) O N
@ P* W @ N W * @ w th @ tp @ *= N 40 2
M
- =
g ort.eD.P)** Mtp W G.N.O. N. N O ED. *.N.
40
- 9. eD. G. tf) W N. P) N. *. N. @. ED. g M. G. b.
o e e a e e e e e e e e e e e e
.. e..
NewNMcNNOgwpweyN L'i O 40 W *= ** b W ** N P) P) Pl P) W N s=
N N P) W w P) W O G ** N ** *= *= W F)
.w 2
N ED oD N P% Ps P% N N Ps N N N N N N O m m m m m @ m e eD eleD e m)
==
W M
@ @ @ @ @ @ @ @ @ tD @ @ @ @ tD @
@@@@@@@@@@@@@@mm ED e tO cD e to tD iD tD N N N N N to cD E
D (D
4 4 t i t i 4 4 4 i i eil l l 9
6 4 4 4 6 8 l l l I I I I 4 I I
@ (D @ (D CD ED ED G tD @ @ @ @ ID @ CD D
O WWWWWWWWWWWWWWWW WWWWWWWWWWWWWWWW t I e1 6 6 e1 4 4 4 4 eiei e 22 N Cn e w N @ M N e w - M eD *. v N e
@ N @ tD N N P) N *= P) w e M m P) S e N P) WWWWWyWWWWWWyWWW O OO F) c to iO N P) v a tO N O G eo w a n
- eD O N N e eD v e e O N a m en N 2
I w @ @ 00 e CD (D O N N to O to
- e *
.J*==
7%@
N T (D C @ @ N W) N e=
- 40 W G r= 40
- ='%@
N E) N O t v.F) W O N P) G G P) G O W N *=
- 2ED CtD e G
- a a e Q *=
2 iD C aO M b e P) N c. N w M v v O m.
2 4( W
- @ @ e= N p *= *= P) tt) O
- O N P)
- W O W O N E)C h # w N M P) N N *tD 0
e e e *
- e e W
J5 N N N N N P% N N N N eD N e tD N S G a s to eD a eD e eD e c e m eD eD e e W
P) N N 9 4 N P) w b e* * *= ** *= @ P)
W OQ (D SD G G @ @ @ @ @ G G @ tD G G G 2 EE l I e4 4 i I e4 4 4 ie4 at ED t i 4 4 4 4 4 4 8 4 6 6 6 6 6 6 2
)
- * * *
- EG WWWWW W e e w @ )eJ W W W W W W W W W W E@ LeJ W W W W W W W W W W W W W W W O ED CD IC ID ED io c eD N N N N N N P-ID j
@QUQ W O.
hN*NGwN"NNN WO
@NONMe* MOON @MONM 4 EWWW P=
= m @ r) O N e @ tO N P) * *= *= P% *
P=
N P% ** W Pi to O 40 eO W P) N e G GD w W l B 4 0 4 4 4 0 t t 4 I il l l DNEE W (D N C. O. N. 4D. W. N. b. G. W. @ @e @ P) S) W Wb N @ W e= N. f0. G. N. N. W. W. N. N. P) C. C.
N WWWWWWWWWWWWWWWW bW 3
3 e..
g g a N N e e w to 4D G P), to @ M F) P%
i
.J 2 2 N N w ** N M
- N N O G e b e *= O P')
N b b b
- w h "
- N P) t 4 W P)* @
O e
N N tO N ID Pi to c eD N @ m 10 O N m CL *=== Q O
6 I
WW(( W NNNNONNNCOOWe@@@
W CemcemmmeceMOMCC M P) N N O.O T G P) N T *=* IO N N M l
eQEE m
@ @ @ @ @ @ @ @ tD @ @ @ @ @ @ @
M
@ @ @ @ tD @ @ b @ @ @ @ @ @ @ @ ^
O T W b tD W O N e= N N N N N " N
- *
- e
= a e
- e * *
< EE w@
4 4 eiI i 0 1 0 4 0 4 4 4 4 i w@
4 it t 4 4 4 4 4 4 6 6 6 e4 6 Q
W WW O WWWWWWWWWWWWWWWW
@ WWWWWWWWWWWWWWWW W s
P= P=
ON D N e d eD @ @ w e C ep eD s)h e N 09 e m ED ED N
- N * @ ED M M e N m e CD W
N*
N N P)40F) N m P) 0 0) m *= M C **to
- = 1D e en W N P4 N P) O N P)
- GO N P)
D N O W N P* N N N Ps N P% Ps P= P= N N E *22
- @ C N G * * @ P) G G e*
- C N ** C @
- O P1*"NG@NG@W@**OCNCO Q
(D@@@@@@@@@@@@@@@
>=W W 2 2
I I i 4 4 6 1 4 5 6 4 6 4 e i 4 W ( CL CL U C O t t0 ** c N e0 *= P) P) N M W **
- U
- * *
- N **
- N M O N G O O N '* E **
0000 WWWWWWWWWWWWWWWW W
t tO S N N e o - O N w to e tD N N eo OW W
W P=
n eD e M e tD N @ N aD N e *= C M a
- 2OEE O O
W e
Neve*@MOMvbb@MMm i 00 4 4
2 C )= 6 6 K 0:
N
- = S 9 *= N ** * ** P) 4CTONM=
G
\\ W4xQQQ >
>O W 2W W
W O
/
i J
- WW (E (Z
M O >=
Q 2 C P-N O MBDW3EEEZWWWWWWW MBNDREkk2W!NWWWWW
== *= M D B k 2 E E 2 W W W W W W W
- =
w Guu
.n=
mmm 222 m in e
.J E mmm 22 Z Z mmm No mmm 222 mem I (D W W
<U m a m 2 2 W W M as: (
to B W 2 2 W W M O O M k 3 2
'aa W m
- K CL DW W
N W3 ecee 2m CD
= EO O C0 2 2
a o:
- J UU <
4 O C6
(V 39270 n790
~h G
LCS - WIXED-WODE RELEASE CORRECTED FOR OPEN TERRAIN RECIRCULATIONTURDINE ENCLOSURE (NORTH VENT) 1991 CORRECTED FOR OPEN TERRAIN RECIRCULATION USING SPECI AL TERRAIN ADJUSTMENT FACTORS RELATIVE DEPOSITION PER UNIT AREA (Wee-2) AT FIXED POINTS BY DOWNWIND SECTORS DIRECTION DISTANCES IN WILES
- eeeeeee***eeeeeeee.
FROM SITE 0.25 0.50 0.75 1.00 1.50 2.00 2.50 3.00 3.50 4.e0 4.50 S
6.933E-09 2.638E-09 1.502E-09 1.021E-09 5.655E-10 3.734E-10 2.683E-10 2.03eE-10 SSW 3.989E-09 1.548E-09 9.080E-10 6.380E-10 3.652E-10 2.469E-10 1.802E-19 1.378E-10 1.592E-10 1. 281E-10 1.052E-19 SW 3.291E-09 6.517E-09 2.472E-09 1.461E-09 1.045E-09 6.119E-10 4.180E-10 3.069E-10 2.355E-10 WSW W
9.885E-09 3.646E-89 2.052E-09 1.387E-09 7.672E-10 5.042E-10 3.610E-10 2.724E-te 2.131E-10 1.506E-10 1.239E-10 WNW 4. 427E-89 1.669E-89 9.610E-18 6.661E-10 3.778E-10 2.532E-10 1.837E-10 1.712E-10 1.404E-10 1.399E e3 1.101E-10 8.877E-11 7.296E-11 NW 4.122E-89 1.593E-99 9.363E-18 6.591E-10 3.781E-10 2.556E-10 1.867E-10 1.428E-10 1.127E-10 9. ;e5E-11 7.493E-11 NNW 5.181E-09 1.924E-89 1.199E-09 7.691E-te 4.358E-10 2.921E-10 2.119E-10 1.614E-18 1.270E-10 1.024E-10 8.418E-11 N
1.161E-88 4.962E-09 2.270E-09 1.522E-09 8.329E-te 5.448E-te 3.890E-19 2.931E-10 2.291E-10 1.839E-10 1.508E-10 NNE 1.767E-48 6.81sE-89 3.796E-09 2.486E-09 1.308E-09 8.365E-19 5.885E-10 4.395E-10 3.417E-10 2.738E-10 2.244E-te t
NE 1.527E-08 6.324E-89 3.625E-09 2.387E-09 1.241E-09 7.930E-10 5.577E-te 4.168E-10 3,246E-10 2.606E-10 2.141E-10 ENE 1.365E-88 6.286E-89 3.488E-09 2.211E-09 1.172E-09 7.442E-19 5.202E-10 3.867E-10 2.999E-10 2.399E-10 1.965E-10 E
2.595E-88 1.059E-88 5.746E-e9 3.685E-09 1.932E-09 1.209E-09 8.358E-10 6.160E-10 4.746E-10 3.777E-10 3.e83E-10 ESE 4.575E-e8 1.643E-08 8.803E-09 5.613E-99 2.907E-89 1.821E-99 1.262E-09 9.311E-10 7.176E-10 5.710E-10 4.655E-10 SE 2.369E-08 8.431E-99 4.576E-89 2.939E-09 1.533E-89 9.665E-18 6.725E-10 4.979E-10 3.847E-10 3.e66E-10 2.503E-10 SSE 1.169E-98 4.263E-09 2.335E-89 1.528E-09 8.162E-te 5.22SE-10 3.679E-10 2.744E-10 2.131E-10 1.703E-18 1.393E-10 DIRECYEDN DISTANCES IN WILES FROW SITE 5.ee 7.50 18.00 15.00 20.00 25.e6 30.00 35.00 40.00 45.00 50.e0 S
8.78BE-11 4.469E-11 2.82 4E-11 1.462E-11 9.876E-12 6.325E-12 4.684E-12 3.616E-12 2.881E-12 2.35eE-12 1.953E-12 SSW 6.043E-11 3.094E-11 1.957E-11 1.816E-11 6.315E-12 4.41eE-12 3.271E-12 2.531E-12 2.020E-12 1.651E-12 1.376E-12 SW 5.636E-11 2.892E-11 1.828E-11 9.474E-12 5.886E-12 4.teeE-12 3.e36E-12 2.345E-12 1.869E-12 1.526E-12 1.27eE-12 WSW 1.035E-te 5.288E-11 3.33EE-11 1.721E-11 1.066E-11 7.377E-12 5.436E-12 4.182E-12 3.323E-12 2.706E-12 2.248E-12 W
1.170E-19 5.926E-11 3.734E-11 1.921E-11 1.186E-11 8.193E-12 6.025E-12 4.629E-12 3.674E-12 2.989E-12 2.480E-12 WNW 6.090E-11 3.184E-11 1.96eE-11 1.813E-11 6.276E-12 4.355E-12 3.214E-12 2.475E-12 1.968E-12 1.682E-12 1.331E-12 NW.
6.261E-11 3.204E-11 2.926E-11 1.35eE-11 6.521E-12 4.548E-12 3.369E-12 2.693E-12 2.975E-12 1.694E-12 1.410E-12 NNW 7.027E-11 3.583E-11 2.263E-11 1.17eE-11 7.264E-12 5.071E-12 3.785E-12 2.963E-12 2.402E-12 1.996E-12 1.700E-12 N
1.257E-18 6.379E-11 4.821E-11 2.874E-11 1.282E-11 8.880E-12 6.543E-12 5.931E-12 3.994E-12 3.249E-12 2.695E-12 NNE 1.873E-16 9.521E-11 6.937E-11 3.148E-11 1.968E-11 1.49eE-11 1.063E-11 6.454E-12 6.956E-12 5.856E-12 5.051E-12 NE 1.792E-19 9.282E-11 5.864E-11 3.894E-11 1.958E-11 1.432E-11 1.118E-11 9.153E-12 7.744E-12 6.687E-12 5.927E-12 ENE 1.641E-te 8.281E-11 5.223E-11 2.732E-11 1.729E-11 1.236E-11 9.519E-12 7.785E-12 6.479E-12 5.56eE-12 4.891E-12 E
2.567E-10 1.280E-18 8.022E-11 4.128E-11 2.573E-11 1.798E-11 1.353E-11 1.069E-11 8.787E-12 7.359E-12 6.368E-12 ESE 3.879E-te 1.934E-18 1.218E-te 6.250E-11 3.846E-11 2.648E-11 1.942E-11 1.488E-11 1.177E-11 9.549E-12 7.900E-12 SE 2.083E-19 1.045E-19 6.588E-11 3.389E-11 2.992E-11 1.448E-11 1.066E-11 8.186E-12 6.491E-12 5.272E-12 4.365E-12 SSE 1.16eE-18 5.832E-11 3.673E-11 1.687E-11 1.164E-11 8.92EE-12 5.899E-12 4.526E-12 3.588E-12 2.915E-12 2.415E-12 RELATIVE DEPOSITION PER UNIT AREA (Wo -2) BY DOWNWIND SECTORS e.......................
SECWENT BOUNDARIES IN WILES DIRECTION
.5-1 1-2 2-3 3-4 4-5 5-18 18-28 20-30 30-4e 40-50 FROW SITE S
1.540E-09 5.813E-10 2.702E-10 1.599E-10 1.055E-10 4.696E-11 1.518E-11 6.492E-12 3.641E-12 2.36eE-12 SSW 9.303E-18 3.733E-19 1.81eE-10 1.091E-19 7.252E-11 3.244E-11 1.054E-11 4.463E-12 2.548E-12 1.658E-12 SW 7.895E-10 3.326E-10 1.662E-10 1.013E-10 6.759E-11 3.029E-11 9.837E-12 4.158E-12 2.361E-12 1.532E-12 WSW 1.501E-09 6.219E-10 3.080E-10 1.867E-10 1.242E-19 5.545E-11 1.789E-11 7.475E-12 4.213E-12 2.719E-12 4
W 2.111E-09 7.880E-10 3.637E-10 2.141E-18
- 1. 4 09E-19 6.236E-11 1.997E-11 8.384E-12 4.664E-12 3.e84E-12 WNW 9.873E-19 3.865E-10 1.847E-10 1.105E-10 7.318E-11 3.259E-11 1.652E-11 4.411E-12 2.493E-12 1.610E-12 Nw 9.591E-10 3.862E-10 1.876E-10 1.130E-10 7.514E-11 3.368E-11 1.e9eE-11 4.602E-12 2.621E-12 1.782E-12 NNW 1.139E-89 4.469E-10 2.131E-10 1.275E-10 8.443E-11 3.762E-11 1.216E-11 5.142E-12 2.984E-12 2.007E-12 i
N 2.336E-89 8.580E-10 3.922E-10 2.302E-10 1.513E-10 6.704E-11 2.155E-11 8.996E-12 5.068E-12 3.265E-12 NNE 3.883E-e9 1.36eE-09 5.95eE-10 3.438E-10 2.253E-10 1.002E-10 3.265E-11 1.417E-11 8.505E-12 5.884E-12 NE 3.674E-09 1.297E-e9 5.641E-10 3.266E-10 2.149E-10 9.655E-11 3.205E-11 1.4 47E -11 9.195E-12 6.718E-12 ENE 3.498E-09 1.213E-09 5.265E-10 3.018E-10 1.973E-10 8.727E-11 2.84eE-11 1.254E-t1 7.757E-12 5.585E-12 E
5.907E-09 2.000E-09 8.475E-10 4.781E-10 3.097E-10 1.354E-10 4.303E-11 1.82 7E-11 1.078E-11 7.425E-12 ESE 9.080E-09 3.026E-99
- 1. 79E-09 7.227E-10 4.677E-10 2.046E-10 6.500E-11 2.685E-11 1.499E-11 9.59BE-12 SE 4.703E-09 1.594E-09 6.611E-10 3.873E-10 2.515E-10 1.104E-10 3.523E-11
- 1. 4 67E-11 6.246E-12 5.297E-12 SSE 2.405E-09 8.441E-10 3.7'8E-10 2.143E-10 1.398E-10 6.153E-11 1.962E-11 8.139E-12 4.561E-12 2.929E-12 VENT AND BUILDING PARAWETERS:
RELEASE HEIGHT WETERS 61 00 REP. WIND HEICHT uETERS 53.3 DIAMETER METERS
'.33 BUILDING HEIGHT WETERS 61.0
392700v90 LCS - dtXED-WODE RELEASE CORRECTED FOR OPEN TERRAIN RECIRCULATIONTURBINE ENCLOSURE (NORTH YENT) 1991 SPECIEIC POINTS OF INTEREST r
RELEASE TYPE OF DIRECTION DISTANCE X/Q X/O X/O D/Q ID LOCATION (WILES)
(WETERS) (SEC/ COB.WETER) (SEC/CU6.WETER) (SEC/CUS.W
_ inorpt rTEDNO DECAY 2.268 DAY DECAY 8.eee DAY DECAY I
N SITE BOUNDARf UNrYPLETED S
0.81 1311.
1.233E-87 1.23eE-97 1.197E-97 1.344E-89 N
SITE BOUNDARY SSW e.49
- 793,
- 1. 890E-87 1.887E-87 1.733E-87 1.579E-09 DEPtrTED N
SITE BOUN9ARY SW 0.61 975.
1.343E-87 1.34eE-87 1.217E-87 9.987E-te t
N SITE BOUNDARY WSW N
SITE BOUNDARY 9.55 884 2.620E-87 2.616E-97 2.385E-07 2.174E-49 W
e.57 914 3.354E-87 3.34 9E-87 3.646E-87 3.e33E-49 N
SITE BOUNDARY WNW 6.55 884 1.790E-47 1.787E-97 1.629E-87 1.463E-99 N
SITE BOUNDARY NW 9.59 945.
1.961E-87
- 1. 977E-87 1.796E-e7 1.282E-99 N
SITE BOUNDARY NNW N
SITE BOUNDARY 6.68 1997.
1.915E-07
- 1. 91eE-87 1.725E-87 1.259E-69 N
6.63 1996.
4.711E-97 4.7e tE-47 4.248E-97 2.948E-99 N
SITE BOUNDARY NME e.55 884 9.122E-87 9.181E-87 8.308E-87 5.952E-89 N
SITE BOUNDARY NE 6.53 853.
1.027E-06 1.925E-96 9.381E-97 5.847E-99 N
SITE BOUNDARY ENE 8.72 1158.
5.246E-47 5.23eE-E 4.747E-97 3.62'E-49 I
i N
SITE BOUNDARY E
e.72 1158.
- 6. 64 9E-97 6.632E-47 6.994E-87 6.124E-09 l
N SITE DOUNDARY ESE e.51 823.
1.385E-eS 1.384E-86 1.266E-96 1.587E-e8 N
SITE BOUNDARY SE e.76 1219.
3.512E-e7 3.586E-87 3.147E-87 N
SITE BOUNDARY SSE e.78 1250.
1.945E-87 1.941E-67 1.74eE-67 2.217E-99 i
i N
RAILROAD TRACKS S
8.19 300.
1.16eE-06 1.159E-96 1.110E-96 1.018E-08 4.500E-89 N
3AILROAD TRACKS SSW e.14 225.
1.515E-96 1.515E-96 1.463E-06 is.529E-99 N
MILROAD TRACKS SW e.14 225.
1.448E-06 1.447E-86 1.396E-06
- 7. 974E-89 N
RAYLROAD TRACKS WSW e.14 225.
2.423E-96 2.422E-96 2.34eE-86 1.437E-es N
RAlf ROAD TRACKS W
e.14 225.
3.357E-86 3.355E -96 3.242E-86 2.292E-es N
RAIL COAD TRACKS WNW e.21 345.
8.174E-87 8.168E-87 7.785E-87 5.418E-49 L
N RAIIROAD TRACKS NW e.28 458.
6.403E-07 6.396E-87 6.933E-97 3.536E-99 N
INFf RMATION CTR ESE S.55 884.
1.247E~e6 1.245E-96 1.134E-96 1.423E-48 N
FRICKS LOCK WSW e.25 450.
7.078E-97 7.872E-07 6.667E-87 5.57eE-99 VENT AND BUILDING PARAMETERS:
RELEASE HEIGHT (WETERSS.
WETERSl 61.06 REP WIND HEIGHT CWETER$1 53.3 DIAMETER
'4 5.33 t
EXIT VELOCITY (W/SEC >
7.68 BUILDING NEIGHT METERSh 61.8
(
BLDG.NIN.CRS.SEC. AREA (SQ.WETIRS 4596.e l
HEAT EMISSION RATE (CAL /SEC) )
9.e l
AT THE RELEASE HEIGHT:
VENT RELEASE WODE WIND SPEED (WETERS/SEC)
AT THE WEASURED WIND HEIGHT (
9.1 METERS)
VENT RELEASE WODE WIND SPEED (WETERS/SEC)
ELEVATED LESS T'MN 1.536 STABLE CONDITIONS WING SPEED TERS/SEC)
ELEVATED LESS THAN e.635 UNSTABLE TRAL CONDITIONS WIXED BETWEEN 1.53f AND 7.666 WIXED LESS THA e.987 GROUND LEVEL ABOVE 7.68e BETWEEN 8.635 AND 3.173 BETWEEN e.987 AND 4.937 i
t CROUND LEVE*.
ABOVE 3.173 ABOVE 4.937 i
i 4
5 k
a 4
1 4
O
/~
fM-O g
ooyoooo g
e4gGoom N
O B.
B k
g oooooo o
y
.oooooo o
N a
a Ch EO l
ooNooo N
l odoooo 4
oooooo o
ommoom W
3 o-oooo 3
-gdooo R
g g
ogwooo g
o ~ooo e
t g
ogwooo g
g ugeooo g
3 as-ooo e
g m
(
0 O
e E
3 g
g
=
o-mooo m
g
-moooo m
g g
R R
al 2
{
g 2 g o-oooo g
o~oooo
~
L g
du
,I y
o-oooo
.E
" g
-voooo e
3 3
f "a
8 8
d 5g o
2 gg enoooo a
3 W
E E
a yw yw o oooo o
a o-ooo.
3 2
S
~
5 gy g
gy oooooo o
oooooo o
R 9
!w g
m w
2 y
oooooo o
-R
-B y
ouoooo u
J '
i' h$
EEg EIg g: n gag g
sogg g oooooo o
e--ooo
~
I" R.
-R E
E E
E W fW gggg =
gggy =
oooooo o
oooooo o
I E
o4 08 I
I RRRRR I
RRRRR
... g E s gr -
saas;S e
e gr -
saas;R e
ze
..:~-
x-r hs issE g c;;;;;~
8 insE -
- 5 8
.. :~;
E Eg sEn assa a as assa a as 4
A
.4
-a4.--.
m.-,.+.-
-A.._-+-,4
-w_,-
4mam4a
--Ls_
A 4
3_w_,.__.h,.4 e A4Ae.
g.$
aeL__.
4_Ca a+m4..hA
.4w
+. - - - = =
-a e
r-O f
ao
@Oo b
4 o39"2*- l b.
o g
g 0
N g
g o g g.e o o g
one-oo
~
N Os to R
Q R
$222**
y l
2N'"
k
[
2RNa"*
g-
=
as-~--
e
=
nues--
a bm g
-,-ooo g
32-ooo a
on.com e
a aR*---
~
a
- ss===
R-a o g s - = = ej C
2 W
3 o
a
.- ecomo e
o g
g g
ggoooo g
a g
R R
- l 4
g ay ou-oo.
g gpoooo g
h
~
~
g ji
. m j i m
na~---
e
-a====
-e s
-e a
2 gg 2
5g gggooo g
o--ooo i
I E~
I E*
o o
o W
o.Nooo e
o W
gg-ooo g
W 5
S S
5 gy 5
[g ggsooo e
ocuoco b
g 3
E B a
e y
R; "w
~===
~
w eRu===
e;s us!
Es e
esRg g seRg g
~se===
s g ::
~-==
a E"A -
E-R g
g g
I!
566E =
5563 =
WRc"**
uag E-o4 08 I
RRRRR 3
I RRRRR I.3.g E 5,,st[
E Ig*2" S"ddddd8
- IE S^
dddd5.E
.TT7J W
I W
t S
s t [_
C
.T J
p.
maaaa~
e gge aaaaa~
e sEi assa ee asst dded bV w.
gny_.r-- ' + =-w +r' W-
- -P-
{
gq my a
we r
9 m
p
-pyw W-p-
--T-g
-w+v--F=v
+
%9'
~'
U '*"
"VA*
O i
R i
(Ob-ogg-oo oggoooo g
N N
3 ogeooo g
a wooooo Os E
E tn g
ggnooo y
y e-oooo u
Rgeaa=
R m===aa s
a ggmooo g
a queooo y
R g
ggn-oo g
g g-oooo g
2 3
gynooo g
g gnoooo g
g ggsoon e
g gmooco g
g
~
g t
t a
g ggeooo g
g gooooo w
p R
R h
Q g g-oooo e
g a
y ggoooo Q
5 gI ll
w xz-==
ji
a e====
a Go g
no g
(
d 5g agoooo g
5 5g gooooo 1
p E~
9 E~
a a
o o
gw gg-ooo g
a emoooo o
gw W
2 S
~
t 5
[ y
-~oooo q
5 gy wooooo 4
A g
g
=
- B w
x 8
8 2
y e--ooo g
y e-oooo e
a B
-B l
$h3 EI !
$Ig R
s*R
$ba===
n saRg g E ::
E"R '_g y
""6***
"R-
=.-
g g
W f I jggg =
gemooo g
j{gy =
u-oooo m
- 5$
8 E-9 9
5-a4 3c8 1
RRRRR 3
I RRRRR Im_gE ine! gI-Egg g-5..
~R g
cggwe^
444dJ 5..
- d.8 dddd r-2 Eg 2
les 9;;;;~
2 sesE -
s;;;;;~
2 saa asse
- us-asse a-~s l
l
,,p,,
-m,-
p
. +,
~r-
.+y
,,,m m
om r"%
h (c~
, agooooo 3
, onne.-
e o
B B.
1 m
y gggmaa y
eooooo m
to g
-ooooo g
ggggoo g~
l guoooo 3
g en-=
a g-oooo g
a ggggn-g it, g
R*****
R g
gg="**
f*
g gooooo e
g ggooo g
e
.R 3*****
3 R
(33"**
A.
e.
t 3
a gooooo g
g g a g
g ggooo g
R R
f j
4 2
g woooo.
~
I..
gggooo g
g O
1 m
=
1
=
ll ll n$n***
g 5 W 3
5*
s s
(
5 6y d
5g gggooo g
oooooo o
5 m
7 E
I E
t*
Scu"**
E n
nI" e
e
.-g $
5 gy 5
gg ggooo.
-coco.
g g
- n9 e
g.
-Q.
g
~ooooo
~
y pgpooo g
a8 7
E tIg Ig L'
g g: c 5*Rg g 5
- R. g g 4Gba**
2
""***=
E" n -
"g g
W i
g g-W f $
gjjg =
gjjg m'
gpg-oo g
cooooo o
- 55 9
9l*N,I E
!!I 8
Is.2.s
- assaa,
- asama,
= n'.,_
coes
=E,',_g ems; t
g.<
ggg E[
5.."T?J 5..T"?'
gggEI-5E33336 2
5333337 2
Ei assa a
2=
nssi
'ddni s
b y
,,m.-.
O O
n 3927067790 s
PAGE 60 PROGRAM: JFD VERSION: PC-1.1 Limerick Generating Station - JFD 30 FT LEVEL - July through December 1991 SITE IDENTIFIER:
DATA PERIOD EXAM!aED: 7/ 1/91 - 12/31/91 SEMI-AmePJAL STABILITY BASED Ou: DELTA T DETWEEN 266.0 AND 26.0 FEET Wie MEASURED AT: 30.0 FEET WIIS THREta0LD AT:
.50 pra TOTAL IR8eER OF OB WRTATIW S: 4416 i
YOTAL IR8WER OF WALID (WEERVATIOus: 4410 TOTAL IR5WER OF MISStuG (20ERVATitust:
6 PERCENT DATA RECOWERY FW TNIS PERItW: 99.9 1 IEAft W!m SPEED FtB TNIS PERIN:
4.T frW IE8WER OF OBSERVATItul$ WITS marew Wie SPEED:
5 IRSWER OF (WSEtv4TIONS WITN tack 1F Wim DIRECTION:
9 IE2WER OF OBSERVATIONS WITN SACEDP STASILITY:
6 TOTAL answer OF (WSEtv4TitWS WITN SACIOP DATA:
9 I
PERCENTAGE OCCURRENCE OF STABILITY CLASSES A
B C
D E
F G
+
1.27 2.77 5.60 41.59 31.52 11.32 5.94 DISTRIBUTich 0F Wie 019ECTION VS STABILITT e
NME WE ENE E
Wuw uW muu CAtsu A
0 0
0 0
0 0
1 1
3 8
32 8
1 0
2 0
0 s
0 2
2 0
1 0
5 2
3 13 36 27 19 8
4 0
0 C
9 3
2 7
6 4
6 3
to 30 49 17 29 37 23 12 0
0 94 66 52 76 75 63 78 90 108 142 112 110 188 280 174 126 0
E 28 35 28 33 35 19 47 61 154 215 187 137 139 179 58 35 0
F 3
5 6
4 8
11 10 18 31 86 122 72 67 45 7
4 0
G 0
1 2
1 3
0 5
7 17 41 78 58 30 17 1
1 0
TOTAt 134 112 92 121 128 97 152 182 326 535 616 429 473 566 269 178 0
~
.... -. _.=..
i
{
t i
O i
.(t t
b O
g ooggmoo y
g o*pgcoa U
l N
B B
l N
m y
y cooooo o
on-coa
~
rn y
conooo n
y o<emoo y
y y
anymoo y
oooooo a
a ow--oo o
=
-gameo g
3 g
ogmooo g
g oppuaa y
3 og<ooo y
g ugsooo 3
g oowooo g
-goooo z
=
e g
e g
o-~~oo e
o g
-4 o
I N
N i
- l 2
2 o
o-oo
.a a
g g
o-oooo 1
=
e 1
dC dC
'I l
3 2
5 8 o-oooo
-moooo e
e ft
~
E*
8 E"
5 2
5g oooooo o
2 gg memooo e
W W
E E
o gw gw oooooo o
o o-u-oo 4
3 5
8 2
l g $
5 gg oooooo o
5 gy oooooo o
)
m
!w A 9 w
2 s
I oooooo o
I anoooo n
J 3
3
$h3
- EEg EEg gy gag oooooo o
gog y
oweoco
~
I"R -
"R E
E E "
5 5
W F W gggg.
gggg.
oooooo o
o oooo o
"E!
9 9
9 o
4 8
RRRRR 3
RRRRR
.gs Egg *2' ddddJE
- I*E^
dddd5.8 5"
t 0
. 777J W
IzEig"we -gggEI-EEEEE7 2
gggEE.
EEEEEY -2 O
. 77
~
assi
- dens assi.
'ddds s
v n o--wp-w 3
m---
m q.,s,.
w.--~r-.., -
,...,----.,-,----.g w
w
~q y--,sm, mp-
,,-ev
i O
Ch N
O 4 *28$$'*
2 t
' S R ; N" Q '
9 N
B B.
"5" R
j m
Ch oogmoo g
a ggeooo 3
a rr)
~
I "2Rb**
3 3
Rb8A**
k n
1 "430"*
2 3~2NR$*
2 eggsoo e
=
ggggs-I G
l
- R sgh***
2~
N f
R
- 4S***
A gg****
R
- 22***
a
.R GGR***
2 g
g
~
g e
d u
-osooo 3
o g
- g gggooo g
u j
N E
N E
j W
3g 3g 4GC***
1 e
g e
g
,i is a!s a
~~oooo
.w sReooo i
p 8
8 2
2 g
oswooo g
gggmoo g
I a
sa o
coo-oo g
a gw gw ggesoo g
W 3
3 5
2 2
t gy gy mg-ooo 4
oc~ooo s
a y
e.
g o
R a e
I y
s s
og y
ecocoo e
y gggono g
C 8 8
T g
EEg EE !
C 2 g s*Rg g 5*Rg y 292***
R E" ::
- aa "R
"R E
g E
g g
f,, t 5555 "
2 R$2"**
g e _s.
EgI IgGI E
a o
gE k 558 I
RRRRR RRRRR
- gr8-acasJR n
- g "r..
acas;R
.m Jt E r E*
5..TT7J m
I e
O 5..TT7J gw.
gggtIg C
g g g E E [.
5333337 2
5%;EEET 2
sEs asst
'ddds asst
'ddds O
t g y y
w..,-
n
-v mr'&*
. =. _ -..
_. - _.. _.. _. _ -. _ = _
O
~
g myggmaa g
g egguooo y
O B
C 8
a
- ~
Os y
gpr.ooo y
l y-oooo y
N Os to E
Ok"***
3 3
2"****
4 a
gggooo e
2 gewooo g
n 5
5 m
ggoooo e
a geoooo 4
~
~
ggn-o.
4 gnomo.
g W
t 3
gggooo g
geoooo g
a n-R
- n.W"**
R h*****
3 g
g g
2 g
gggooo n
g w
a a
g~oooo 3
~
N E
E N
j 3g a3****
8 E
a"****
a lg E
5 l
E j
g W
Ss"***
3 W m*****
z 3
[
E' 8
Ea 5
2 5g gg-ooo y
2 5g gooooo 2
W 7
3 E
o g=
ggomeo g
g=
geo***
2 a
a W
3 5
S
-2 3
$w shN"**
c 5
Kw ca*o**
e
)
g n
w an e
e o
3 3
,g g
AgNaco g
g Asocoo p
e B
7.(
C B k'
5 "E
E
- E E
e :s seag g nt~o-o is seaa g a
~~oooo E"a -
- a g
g g
[,,!
$$$$ =
42a***
3
$$$$ =
W al a su seen GIEs 8 II massa aggy gaggg I.3gz e gsg-seasga e gug- =sa~sga W
3 ~ Kg
..TT.f l
y,,'tsEg
~
3 Ba..TT.Jammar e
p.
gge z.
assaa.
e l
355 assi
'dded ass
'ddid C
\\
O
("h Nh
~
W "RR****
k W ***ggn" g
OR-O E
5 a
s Ne g
g ggggoo g
.cocco 4
rn g
oooooo e
g ggggoo g
i E***"*
8 I
ScE~5*
8
~
gyngn-g s
g-oooo q
a G
g g
gyh2**
g W<'
3 gooooo g
g y goo.
.A 3
g*****
2 a
gg&***
5
=.-
o E
E E
gooooo g
y g
6gg~oo y
o g
g
~
j 2
E E
N g
aN g
a a
~oooo.
~
g g
~ggeo.
~
I:
I 1
3.
R o
"E
,W E
=W A82***
g I
i 3
5 p
8 2
sooooo
~
2 gg gggmoo g
1 gg w
g g
E 3
g*
g*
S g S' * *
- g A
A e
e 5
gy gy mooooo m
kgooo E
g e
g a.
g e
W m
w
- B e
y o
~;....
g J
-B
-B
$h$
EE5 EIB E,e a.g y g :. >
s E, egg g s
aan*==
c
~
_g g
g
[,,!
5555 "
5555 "
RR$~
g SEE lalE a[!s Q*
e}Es 85 #
a==ag g
gagga "a
nggw -
aaa; ngywo- =aa eau a
...*x e
a 5,,sEg Sa..~:~g x
2 p.
Eg Sa..::~
s 2
255 g
,=t
' deed assi
'd"ds assa~
e maan.
e ass y
_ - - * +,
, ww
~c..
v.-
~
39270k90 i
a PAGE 66 PROGRAut: JFD VER$10N: PC-1.1 Lianerick Generating Stetton - JFD 30 FT LEVEL - January through December 1991 SITE IDENTIFIER:
DATA PERIOD E1UWetuED: 1/ 1/91 - 12/31/91
= AmuuAL
- STASILITY BASED Ou: DELTA T SETWEEN 266.0 Ano 26.0 FEET WIS MEASURED AT: 30.0 FEET WIIS THRES#0LD AT:
.50 are TOTAL utDeER OF OBSERVATIONS: 8760 TOTAL NIDGER OF WALID DOM RVATI0ms: 8753 TOTAL GR8eER OF MISSING OBSERVATIONS:
7 PERCENT DATA RECOWERY FOR TNIS PERitE: 99.9 1 MEA 81 WIIS SPEED Fth TNIS PERIGB:
5.2 tes
-IR8eER OF OBSERVATIONS WITN SACEUP Wise SPEED:
7 uuteER OF OSSERVATIONS WITN mm Vlue DIREtit0N:
9 ImmeER OF OBSERVATIONS WITN SACKUP STA8illTY:
56 TOTAL 9EpeER OF OSSERVATIows WIT 4 BACKUP DATA:
61 PERCENTAGE OCCLRRENCE OF STABILITY CLASSES
-A B
C D
E F
G
.99 2.56 5.95 45.50 29.58 9.M 5.45 DISTRipuTIou 0F Wile DIRECTION VS STABILITY N
uuE WE ENE E
WRt NW uuW CALM A
0 0
0 0
0 0
1 1
5 11 42 16 9
0 2
0 0
s 0
2 2
0 4
3 6
5 9
21 49 48 37 23 13 2
0 C
16 10 5
7 19 11 9
4 16 55 66 54 70 87 68 24 0
0 207 133 132 254 254 131 116 138 196 276 194 210 405 695 397 244 1
E 49 56 56 73 85 52 96 104 243 346 363 267 276 319 131 68
-3 4
F 8
11 9
18 20 20 22 33 56 141 172 109 134 80 22 13 4
c 3
3 6
3 11 7
11 12 32 62 108 94 65 40 8
4 8
TOTAL 283 215 210 355 393 224 261 297 557 912 994 798 996 1244 641 355 18 t
t A
O Ch N
N 6%
N g
ooogeoo g
g o-ggg-o g
g g
Os rn y
g
---.o.
m y
ooo-oo 3
oomuoo n
y g
oooooo o
oommoo e
3 no.oo.
3 ouncoo a
R g
g o geoo g
oceuco e
2 g
omgwoo y
3 aogu-o g
y oemeco y
y ommeoo 1
0
- C
=
j 8
g a
ca-moo m
g
=
ommooo N
N 2 y oowooo 4
y 1 g ocuooo
~
f t
5 h
h 20 g
tr "g
oooooo o
20 g
o--ooo
~
s e
no g
Go g
5 N
$g d
5g oooooo o
omoooo m
4 W
- W
- E E
o gw oooooo o
o o-como E
N 5
gw e
e
~
t 5 5
gy oooooo a
5 gy ano...
c.
N s-E a-a
-d s
e, s
y oooooo o
y oeuoo.
~
B 0 B T
(
~2E[
E g 8
=
sogg y sogg y oooooo o
oo~oo.
~
-e -
-n z=
- s.,
s.r 9 gggg.
gggg.
oooooo o
oooooo o
- 53 9
9 E
o
...'8 I
RRRRR I
RRRRR I3gG g, K[.
e y r, -.
saaa;R
- W g r -.
sawa;R e
r
..TT?J 5
5[
..v;?J s
3.<
asama~
e sEl assE
'dded 5,,E
'ddde aamma~
e-ass
o th N
5u~
O W
- R$3;"
O W
'Ugg2*E y
N B.
B
~
Os j
2 g
- RRA:*
g tn E
""2***
A E
"RSES" E
g 3**
A g
"3cER3 g
- Wha" 2
8 2mRR2*
3 sm g
ouenoo e
oge.-o y
g agg
-o g
g egg.co g
R
- ~2-*
R R
5034"*
O g
j u
g
--m<-o y
a g
gggpoo 3
)
l 3
b 3
0 1
3, a
4 y
omoooo u g
egggoo g
E E
E is
=nn.oo is e-mooo 5
"a 5
8 3
4 5g ommooo 2
5g spg.oo g
4 W
W w
E
~
g gw gw gggeoo g
a on--oo e
o 5
I g
o O k 5
gy ouvooo e
E
$y egguoo g
c-m g
W w
=
a y
a y
e, ".
s s
y ammooo 4
y egggoo g
8 7.(
0 8 k'
5
- I "E
E c
=""***
,E :
2*Rg g s*Rg g "ah==*
3 3
R' z"R
[,, g e
e E
5555 "
- 10$a"*
3
- EI li E'
=
o 4
8 8
RRRRR RRRRR
.. -g5 t g'gn AaddJR C*g'tg-[
AaadfR g
.2 t
..Ti"J g.
O I lOEH ggy E[.
"a. 77.J S masa~
a 3.<
maaaa~
e ggy st.
asst
'dded asst
'dded
\\
O 39270690 PAGE 58 PROGRAM: JFD WERSION: PC-1.1 Llmerick Generating Station - JFD 175 FT LEVEL - July through Decodwr 1991 SITE IDENTIFIER:
DATA PERIOD EXAMINED: T/ 1/91 - 12/31/91
- SEMI-ANNUAL **
STASILITY CLASS E STASILITY BASED ON: DELTA T DETWEEN 266.0 AND 26.0 FEET I
WIND EASURED AT: 170.0 FEET WIS THRESNOLD AT:
.50 arN JOINT FREGUFMCY DISTRISWi!ON OF WIND SPEED AND DIRECTION IN NGJRS Af270.00 FEE ~
SPEED (NPN)
N NME NE ENE E
ESE SE
$$E 5
WW NW NNW TOTAL j
CALM 0
.51-3.50 4
2 3
3 5
2 7
to 12 8
7 5
3 4
8 1
89 3
3.51-7.50 15 8
9 20 18 17 13 15 23 42 55 45 41 42 19 to 392 7.51-12.50 22 19 25 to 10 7
to 23 63 100 66 54 37 111 58 22 637 12.51-18.50 12 6
5 0
3 6
4 to 25 30 15 8
9 41 16 13 206 18.51-24.50 2
0 1
0 0
0 0
0 1
3 1
3 1
6 2
1 21
>24.50 0
0 0
0 0
0 0
0 1
0 0
0 1
0 0
0 2
TOTAL 55 35 43 33 36 32 34 58 128 183 144 115 97 -~
fn3 47 134T 204 STAAILITY CLASS F STASILITT SASED ON: DELTA T BETWEEN 266.0 AND 26.0 FEET WIW E ASURED AT: 170.0 FEET WI W TNRE$NOLD AT:
.50 prN JOINT FREGUENCY DISTRIBUTION OF WIS SPEED AS DIRECTION IN NOURS AT270.00 FEET SPEED (sPN)
N NME NE ENE E
WWW WW NuW TOTAL CALM 0
'.51-3.50 3
2 2
0 2
2 6
12 10 7
4 8
to 9.
T 3
87 3.51-7.50 7
4 9
4 T
2 8
5 19 7
21 21 30 48 35 15 242 7.51-12.50 0
5 1
1 0
0 2
2 6
7 7
20 54 23 2
139 12.51-18.50 1
0 1
0 0
2 0
0 0
1 1
2 2
13 0
0 23 18.51-24.50 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24.50 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL 11 11 13 5
9 6
16 19 35 22 33 51 51 124 65 20 491 4
V t
M O
O
-392700;/790 PAGE 59 PROGRAMt JFD VERSION: PC-1.1 Limerick Generating Station - JFD 173 FT LEVEL - July throuNh Decenter 1991 SITE IDENTIFIER:
DATA PEtIOC 2XAMINED: T/ 1/91 - 12/31/91
- SEMI-ANNUAL **
STASILITY CLASS C STASILITT SASED ON: DELTA T BETWEEN 266.0 AND 26.0 FEET WIW NEASURED AT: 170.0 FEET WIW THRESNOLD AT:
.50 wW JOINT FREeJENCT DISTRIEJTION OF WIN SPEED AND O!RECTION IN NOURS AT270.00 FEET SPEED (WW)
N NME NE ENE E
WNW NW kWW TOTAL CALM O
.51-3.50 2
2 1
2 5
2 4
1 8
2 7
6 11 11 8
2 74 3.51-7.50 3
1 0
1 0
1 0
9 3
10 7
5 12 45 24 7
128 T.51-12.50 1
1 1
0 0
0 0
1 2
3 5
2 4
13 11 2
46 12.51-18.50 0
0 0
0 0
0 0
0 0
0 0
0 0
4 0
0 4
18.31-24.50 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24.50 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
101AL 6
4 2
3 5
3 4
11 13 15 19 13 27 73 43 11 252 STASILITY CLASS ALL STABILITT SASED ON: DELTA T DETWEEN 266.0 A m 26.0 FEET WIW MEASURED AT: 170.0 FEET WIND THRESNOLD AT:
.50 MPN JOINT FREGUENCY DISTRIBUTION OF WIND 2PfED AND CIRECTION IN NOURS AT270.00 FEET
' SPEED (MPN)
.N NNE ME ENE E
WNW WW WWW TOTAL 0
CALM
.51-3.50 17 13 12 13 27 13 30 29 43 36 27 27 39 33 27 11 397 3.51-7.50
'51 45 36 76 59 59 46 53 80 114 151 113 124 178 111 66 1362
)
7.51-12.50 73 65 61 45 41 32 45 63 138 194 166 136 120 267 165 89 1700 12.51-18.50 47 23 20 2
12 14 10 20 47 70 32 24 61 156 109 56 703 18.51-24.50 4
0 1
0 0
0 0
0 2
7 3
4 23 51 20 12 127
>24.50 0
0 0
0 0
0 0
0 1
0 0
0 8
14 1
0 24 TOTAL 192 146 130 136 1M
.118 131 165 311 421 379 304 7 699 433 234 ~~4. 3
O O
3927 9 7790 PAGE 60 PROGRAM: JFD VERSION: PC-1.1 Limericit Generating Station - JFD 175 FT LEVEL - July through December 1991 SITE IDENTIFIER:
DATA PERIOD EXAMINED: 7/ 1/91 - 12/31/91
- SEMI-ANNUAL **
STAstLITY SASED ON: DELTA T DETWEEN 266.0 Am 06.0 FEET WIND MEASURED AT 179.0 FEET Wile TNRESNOLD AT:
.50 8FM TOTAL IRSEBER OF OBSERVATIONS: 4416 TOTAL IRSEBER OF VALIS OBSERVATIONS: 4313 TOTAL IRsEBER OF MIS $1NG OBSERVATIONS:
103 PERCENT DATA RECOVERY FOR TNIS PERIOD: 97.7 1 MEAN WIND SPEED FOR TNIS PERIOD:
9.0 IIPN
~ IR5GER OF OBSERVATIONS WITN SACRUP WIIS SPEED:
0 BR8eER OF (BSERVATIONS WITN SACIGP WIND DIRECTION:
0 IRDWER OF OBSERVATIONS WITN BAOOP STABILITY:
0 TOTAL Nt#E9ER OF OBSERVATIONS WITH SACEUP DATA:
O PERCENTAGE OCCURRENCE OF STASILITY CLASSES A
B C
0 E
F G
1.28 2.83 5.73 41.71 31.23 11.38 5.84 DISTRIBUTION OF WIND DISECTION VS STASILITY N
sNIE NE ENE E
lAIW NW INIW CALM A
0 0
0 0
0 0
0 2
3 13 27 8
4 0
1 0
0 s
0 2
2 0
1 3
l' 2
4 14 23 28 a
6 5
3 0
C S
6 4
6 5
6 6
2 12 30 43 17 28 33 23 18 0
3 112 88 66 89 83 68 69 71 116 147 85 T2 146 259 193 135 0
E 55 35 43 33 36 32 34 58 128 183 144 115 97 204 103 47 0
F 11 11 13 5
9 6
16 19 35 22 33 31 51 12 <,
65 20 0
G 6
'4 2
3 5
3 4
11 13 15 19 13 27 71 43 11 0
TOTAL 192 146 130 136 139 118 131 165 311 421 379 304 375 699 433 234 0
[
m_____
O Ch N
,N3
\\j -
N i
- SRO**
i
- "4kR*"
2 N
B B
N Os aooooo o
--mooo e
y ooo-oo y
oocemo e
g jo g
oooooo oomsco 3
1 2
oo---o m
2 omggn-4 g
o-o
-o 3
g ooggum 3
8 2
g omg oo g
g ooge-o g
g o.s-oo n 3
o gooo 4
t a
g e
I e
g
=
co-umo e
g ommmue o
5 R
R
=
=
y y
U Q
U a
g oowooo u
d
\\
l 20 g
oooooo o
20 6
g on-ooo m
5 3
22 b
E E*
5 5
l 2
5g 2
5g oooooo o
om-coo o.
=
E a
E s
o g-g=
oooooo a
o o-oooo E
~
S a
e gg gy oooooo o
oooooo o
ee
-~
z E
'y g
oooooo o
ocuoco
=
i 7E
=E O=8 2 g 3
EkB
-tkB gg3
,q g oooooo o
go g
oowoo.
~
a x z-a
- =
5 f $
jggj =
ggg[ =
oooooo o
oooooo o
R }5!
5 9*0.E8I 5 9e*gy E
Es ag gaggg aassa
... g :t
<gro seassa
- <gro-seassa
., E 5
E m
.2 g..
s g u R'
- s a.. T T ? J e C
5..TT";
5 5,,
5g masaw samamat a
e
- 53 Bssi
'ddss assi
'ddss O
O 39270790 PAGE 63 PROGRAM: JFD2 VER$10N: PC-1.1 Limerick Generating Station - JFD 175 FT LEVEL - January through December 1991 SITE IDENTIFIER:
DATA PERIOD ENAMINED: 1/ 161 - 12/31/91
- ANNUAL ***
STASILITY CLASS C STASILITY SASED Cal: DELTA T SETWEN 266.0 AND 26.0 FEET WIND MEASURED AT: 170.0 FEET WIND flNtESNOLD AT:
.50 wN JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS Af270.00 FEET
. SPEED (MPN)
N NME NE ENE E
WNW NW NNW TOTAL CALM O
.51-3.50 0
0 0
0 0
0 0
0 1
2 0
1 0
1 1
0 6
3.51-7.50 1
'4-4 2
5 6
1 2
3 7
20 12 11 7
6 9
100 7.51-12.50 8
6 3
4 5
9 8
0 7
27 26 09 29 17 22 14 204 12.51-18.50 7
4 0
0 1
5 0
0 5
18 11 15 20 29 27 to 152 18.51-24.50 0
0 0
0 0
0 0
0 1
1 1
1 7
16 13 4
44
>24.50 0
0 0
0 0
0 0
0 0
0 0
2 5
4
-3 1
15 total 16 14 7
6 11 20 9
-2 17 55 58 50 72 74 72 38 521 STAtlLifY CLASS 0 l
STASILITY BASED ON: DELTA T BETWEEN 266.0 AND 26.0 FEET 3
WIND MEASURED AT: 170.0 FEET WIND THRESNOLD AT:
.50 MPN JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECil0N IN HOURS AT270.00 FEET SPEED (mph)
N NME WE ENE E
WNW NW WNW TOTAL utM O
.51-3.50 18 11 12 11 22 14 19 15 20 24 17 20 21 12 10
.8 254 3.51-7.50 50 65 39 107 66 63 43 35 50 66 54 47 70 85 63
'47 950 7.51-12.50 99 89 81 113 132 46 41 41 118 59 51 72 167 141 95 1441 l
12.51-18.50 55 25 15 to 53 24 12 22 39 69 14 24 91 200 192 87 932 i
18.51-24.50 7
1 0
0
-5 1
1 5
1 5
0 7
55 105 60 21 274
>24.50 0
0 0
0 0
0 0
0 0
0 0
4 13 71 8
1 97 total 229 191 147 241 278 148 116 118 206 282 144 153 322 640 474 259 3968 t
I I
=
O e
3927 0 7790 PAGE 64 PROGRAM: JF0 VERSION: PC-1.1 Liedrick Generatics Station - JFD 175 FT LEVEL - January through December 1991 SITE IDENTIFIER:
DATA PERIOD EXAMINED: 1/ 1/91 - 12/31/91
- ANNUAL
- 3fASILITY CLASS E I
STASILITY SASED ON: DELTA T SETWEEh 266.0 AND 26.0 FEET WIW MASURED AT: 170.0 FEET WIN TNRESNOLD AT:
.50 MH JOINT FREGUENCY DISTRIOUTION OF WIS SPEED AND DIRECTION IN NOUR$ ATZ70.00 FEET SPEED (NPN)
N NME NE ENE E
neuf NW NNW TOTAL 0
CALM
.51-3.50 7
5 8
7 6
6 to
'21 18 15 14 6
10 9
11 2
156 3.51-7.50 25 15 19 48 26 30 33 26 41 60 83 75 85 93 40 16 715 7.51-12.50 37 29
'35 19 24 16 18 46 96 152 130 106 94 211 104 41 1158 12.51-18.50 16 to -
9 2
15 13 12 16 57 63 36 26 30 96 37 24 462 18.51-24.50 2
0 1
0 5
1 0
1 3
6 8
3 4
12 5
1 50 m24.50 0
0 0
0 0
0 0
0 1
2 1
0 1
0 0
0 5
TOTAL 87 59 T2 76 74 66 73 110 216 298 2 72 216 225 421 197 84 2546 STASILITY CLASS F STASILITY BASED ON: DELTA T BETWEEN 266.0 AND 26.0 FEET Wie MEASURED AT: 170.0 FEET
,Wie THRESNOLD AT:
.50 WM JOINT FREGLENCY DISTRIOUTION OF WIS SPEED Am DIRECTION IN NOURS AT270.00 FEET SPEED (wM)
N NME NE ENE E
WNW WW-NNW TOTAL P
CALM
.51-3.50 3
3 6
2 7
5 7
12 16 17 11 12 12 13 4
140 3.51-7.50 16
- to 17 9
to 6
13 to 24 18 41 w
55 76 57 23 425 i
7.51-12.50 6
8 3
2 4
1 3
3 8
8 20 33 20 95 31 6
251 12.51-18.50 2
1 1
0 1
4
'O O
1 2
5 2
2 23 1
1 46 18.51-24.50 0
0 0
0 0'
O O
O
'O O
O O
O 2
0 0
2
>24.50 0
0 0
0 0
0 0
0 0
.0 0
0 0
0 0
0 0
total 7
22 7 13 22 16 23 7 49 45 7 85 89 208 102 34 864
-,-.6,.u=-
--...--m e
P
O 39270790 PAGE 65 PROGRAM: JFD YER$10N: PC-1.1 Limerick Generating Station - JFD 175 FT LEVEL - January through December 1991 SITE IDENTIFIER:
DATA PERIOD EXAMINED: 1/ 1/91 - 12/31/91 Augugt t
STASILITY CLASS G STASlilTY SASED ON: DELTA T SETW EN 266.0 AND 26.0 FEET WIND MEASURED AT: 170.0 FEET WIIS THRESNOLD AT:
.50 MW JOINT FREeuENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN NOURS AT270.00 FEET SPEED (WW)
N NME NE ENE E
WNW W
NNW TOTAL CALM 0
. 51-3.50 3
2 2
3 6
2 8
3 12 9
14 13 16 13 8
3 117 3.51-7.50 9
2 1
5 2
6 1
to 7
15 19 13 29 73 41 13 246 7.51-12.50 1
2 1
0 1
2 0
1 2
3 9
5 6
42 18 3
96 12.51-18.50 0
0 0
0 0
0 0
0 0
0 1
0 0
7 0
0 8
18.51-24.50 0
0 0
0 0'
0 0
0 0
0 0
0 0
0 0
0 0
>24.50 0
0 0
0 0
0
.0 0
0 0
0 0
0 0
0 0
0 TOTAL 13 6
4 8
9 10 9
14 21 2;
43 31 51 135 67 19 467 l
STABILITY CLASS ALL STASILITY SASED ON: DELTA T BET W EN 266.0 AND 26.0 FEET WIND MEASURED AT: 170.0 FEET WIND THRESNOLD AT:
.50 MPN JolNT FREQUENCY DISTRIOUTION OF WIND SPEED AND DIRECTION IN NOURS AT270.00 FEET SPEED (MPN)
N WWE WE ENE E
1And W
NNW TOTAL CALM 0
.51-3.50 31 21 28 23 41 27 44 51 67 67 56 50 60 47 43 18 674 3.51-7.50 101 80 171 110 114 93 83 127 174 232 197 255 334 207 109 2483 7.51-12.50 151 136 125 138 166 75 71 97 213 327 292 248 257 537 321 162 3316 12.51-18.50 80 40 25 12 70 51 24 38 107 161 76 82 155 362 266 122 1671 18.51-24.50 9
1 1
0 8
2 1
6 9
12 to 14 70 140 83 26 392
>24.50 0
0 0
0 0
0 0
0 1
2 1
8 20 75 11 2
120 i
TOTAL 3 72 294 259 344 395 269 233 275 574 143 667 599 817 1495 931 439 8656 r
I) a 39270',07790 PAGE 66 PROGRAM: JF0 VERSION: PC-1.1 f
Limerick Generating Station - JFD 175 FT LEVEL - January throuNh Decoster 1991 SITE IDENTIFIER:
DATA PERIOD EXAMINED: 1/ 1/91 - 12/31/91 anguAL ***
STASILITY SASED ON: DELTA T SETWEEN 266.0 Ale 26.0 FEET I
WIND MEASURED AT: 170.0 FEET l
WIIe THRESNOLD AT:
.50 prN TOTAL IRAGER OF OBSEtw?.it0NS: 8760 TOTAL IRAGER OF YALIO (WSERVAfl0NS: 8656 TOTAL IRAGER CF MISSING 099ERVATIONS: 104 PERCENT DATA RECOVERY F02 TNIS PERI (B: 96.8 %
MEAN WING SPEED FOR TNtS PERI (2:
9.8 frN
" IR8WER OF OBSERVATIorst WITN BACKUP WIND SPEED:
19 3 RAWER OF OBSERVATIONS WITN BACKUP WIND DIRECTION:
21 IR5WER OF OBSERVATIONS WITN BACKUP STAsILITY:
50 TOTAL IRAWER OF OBSERVATI(NIS WITN BACKUP DATA:
7D PERCENTAGE OCCURRENCE OF STAelLITY CLASSES A
B C
D E
F G
.99 2.59 6.02 45.61 29.41 9.98 5.40 DISTRIOUTICII 0F WIND DICcCTICII VS SitJILITY N
INIE isE ENE E
'S 594 SW WSW W
WWW.
IIW IINW CALM A
.0 0
0 0
0 0
0 2
5 12 37 16 13 0
1.
0 0
s 0
2 2
0 1
9
.3 4
to 24 36 48 45 17 18.
5 0
C 16 14 7
6 11 20 9
2 17 55 58 59 72 74 72 38 0
D 229 191 147 241 278 148 116 118 206 292 144'.
15L 322 640 474-259.
0
-E 87 59 72 76 74 66 73 110 2t6 298 2 72 216 225 421 197 84 0
F 2T 22 27 13 22 16 23 25 49 45 77 85 89 208 102 34 0
G
'13 6-
. 4 8
9 10 9
14 21 27 43 31 51 135 67 19 0
TOTAL 3 72 294 259 344 395 269 233 275 524 -
43 667 599 817. 1495 931 439 0
p t
I s
a