Submits Sample Plans to Be Used to Test Representative Sample of Snubbers for Each Snubber Type,Iaw TS 4.7.5.e. Informs That Sample Plan for Mechanical Medium Snubber Type Being Changed,Due to Project Reducing of Total Population
ML20094E733
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 09/15/1995
From: Storz L
Public Service Enterprise Group
To: Martin
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
NUDOCS 9511070387
Download: ML20094E733 (2)


Text

. -. ._ - .- -- - . . - . - - - .. -

Public Service Electne and Gas Company P.O. Box 236 Hancocks Bndge. New Jersey 08038 0236 Nuclear Business Unit SEP 151995 l LR-N95143 Regional Administrator U. S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406-1415

Dear Mr. Martin:

SNUBBER TESTING SANPLE PLAN HOPE CREEK GENERATING STATION L; OKET NO. 50-354 PSE&G is making this notification in accordance with Technical Specification 4.7.5.e.

Beginning with the Hope Creek sixth refueling outage, the following sample plans will be used to test a representative sample of snubbers for each snubber type: l Total Quantity Type Poculation Samole Plan of Samole Compensating Strut 9 TS 4.7.5.e.1 1 Hydraulic Large 37 TS 4.7.5.e.1 4 Hydraulic Medium 1 TS 4.7.5.e.1 1 Hydraulic Small 11 TS 4.7.5.e.1 2 Mechaniccl Large 144 TS 4.7.5.e.1 15 Mechanical Medium 344 TS 4.7.5.e.1 35 Mechanical Small 62 TS 4.7.5.e.1 7 The Hope Creek snubber reduction project significantly reduced the total population of mechanical medium type snubbers, so the sample plan for that snubber type is being changed.

070073 9511070387 950915 PDR ADOCK 05000354 P PDR l 0

NkM /hb

Regional Adminirtrator SEP 151995 LR-N95143 Should you have any questions regarding this matter, please do not hesitate to contact us.

Sincerely, msv ,

A _'

L. F. Storz Senior Vice President Nuclear Operations C U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Mr. D. Jaffe, Licensing Project Manager - Hope Creek U.S. Nuclear Regulatory Commission i One White Flint North l 11555 Rockville Pike l Mail Stop 14E21 Rockville, MD 20852 Mr. R. Summers USNRC Canior Resident Inspector Hope Creek Generating Station Mr. K. Tosch, Manager IV  ;