-m
._,_.A.
jo _
13
~f-GENuclearEnergy s
E. Quinn, Projects Manager General Electric Com LMR and SBWR Programs 17S Curtner Avenue. A 16S San Jose. CA 951251014 408 925-1005 (phone) 408 925-3991 (facsimile)
October 25,1995 MFN 245-95 Docket 52-004 Document Control Desk U. S. Nuclear Regulatory Commission Washington DC 20555 Attention: Theodore E. Quay, Director Standardization Project Directorate
Subject:
SBWR - PANTHERS /IC Apparent Test Results (ATRs), Phase 1 (Non-Proprietary)
Reference:
1.
I.etter from J. E. Quinn (GE) to T. E. Quay (NRC), SBWR -
Updated Status of Test Documentation Submittals, MFN 125-95, July 24,1995.
The attachment to this letter supplies the PANTHERS /IC Apparent Test Results (ATRs),
Phase 1, which satisfies Item 56 of Reference 1.
Si a es nn, P
s Manager
Attachment:
PANTHERS /IC Apparent Test Results (ATRs) Reportsfor tests: HSD03, HSD09, HSD10, HSD12, T02, T03, T04, TOS, T06, T07_1, T08, T09. T10, T11, T14, T15, T17_A, T17_B, T17_C, T17_D, and T17_E.
CC:
P. A. Boehnert (NRC/ACRS) (2 paper copies w/att. plus E-Mail w/ att.)
I. Catton (ACRS)
(1 paper copy w/att. plus E-Mail w/ att.)
S. Q. Ninh (NRC)
(2 paper copies w/att. plus E-Mail w/ att.)
J. H. Wilson (NRC)
(1 paper copy w/att. plus E-Mail w/ att.)
00099 9511060104 951025 PDR ADOCK 05200004 A
PDR ghg',
j 1
7
G GENuclearEnergy MFN 245-95 bec: (E-Mail w/ att. except as noted)
N. E. Barclay J. A. Beard P. F. Billig R. H. Buchholz T. Cook (doe)
(2 paper copies w/att. plus E-Mail w/ att.)
J. D. Duncan R. T. Fernandez (EPRI)
J. R. Fitch J. Fox P. C. Hecht J. E. Leatherman J. E. Quinn T. J. Mulford (EPRI)
(2 paper copies w/att. plus E-Mail w/ att.)
P. E. Novak F. A. Ross (doe)
B. Shiralkar R. Srinivasan (EPRI)
J. E. Torbeck GE Master File (1 paper copy w/att. plus E-Mail w/ att.)
SBWR Project File (1 paper copy w/att. plus E-Mail w/ att.)
.~
Checked by Approved by Pace Of Date Description Prepared by,
//
/
by LETM N.2.s43
%Sjppfu[/..
S. B P. Masoni 1
/#
01 Aug.1995 Issue SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : Shakedown NUMBER : HSD03 TEST DATE : 05 July 1995 TEST OBJECTIVE :
Measure the heat loses in the steam inlet line at 4 MPa.
DATA RECORDING PERIOD REFERENCE TEST TIME Stan :
16:17 Stop :
16:44 Start :
16:17 Stop :
16:42 I
DATA FILE NAMES Historic TH values:
SH060795.STO TM quantities:
not recorded TH quantities:
HSD03.DAT Vibrations:
not recorded FAILED OR UNAVAILABLE INSTRUMENTS:
T-N001 T-1001 T-1002 T-2001 T-Q010 T-Q014 T-QO21 F-2001 P-E001 DP004 LDT001 LDT002 LDT003 All accelerometers ZERO NOT IN TOLLERANCE INSTRUMENTS :
DP001 DP006 DP008 DP020 DP021 DP023 DP025 DP028 DP029 DPEFM1 DP-I001 DP-Q005 DP-Q006 F-A001\\a F-A001\\b L-H001 L-1001 P-A002\\a P-F001 ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL :
DP010 DP012 L-P001 L-Q001 L-Q002 OVER RANGE SIGNALS : NONE
-DEVIATIONS FROM TEST PROCEDURES-: NONE PROBLEMS AND DISFUNCTIONS :
Loss of steam on the steam vessel inlet flange. This dose not effect the test results.
HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
Date Description Prepared byl,
Checked by Approved by Page Of Ev t im A 1[tl, i2/
S. Both" Pgasong i
//
01 Aug.1995 Issue SIET spa PANTHERS-IC APPARENT TEST RESULT 1
TEST TYPE : Shakedown NUMBER : HSD09 TEST DATE : 19 July 1995 TEST OBJECTIVE :
Part 1 - Measure the heat loses in the steam inlet line at 8 Mpa Part 2 - Measure the effect of smallleakage of Drain Valves F117 and F136 DATA RECORDING PERIOD REFERENCE TEST TIME Start :
16:53 Stop :
18:14 Part 1 Start :
16:54 Stop :
17:08 Part 2 Start :
17:40 Stop :
18:14 DATA FILE NAMES Historic TH values:
SH190795.STO TM quantities:
HSDTM09.DAT TH quantities:
HSD09.DAT Vibrations:
not recorded FAILED OR UNAVAILABLE INSTRUMENTS:
T-1001 T-1002 T-2001 T-Q010 T-Q014 T-Q021 DP004 LDT001 LDT002 LDT003 All accelerometers ZERO NOT IN TOLLERANCE INSTRUMENTS :
DP004 DP005 DP006 DP029 DPEFM1 DP-1001 L-A001 L-1001 ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL DP010 DP012 L-P001 L-Q001 L-Q002 DP-Q005 DP-QOO6 OVER RANGE SIGNALS : NONE DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS :
Valve F131 was out of order and therefore bypassed for this test.
Part 2 has been performed with IC pool level lower than requested HAS THE TEST CBJECTIVE BEEN REACHED ?
Part 1: YES Part 2: NO HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
4 Date Description Prepared by, Checked by Approved by Page Of il b >' t.iT T W-j
,4vegih, S. Bohr
{. pag 1
/g 01 Aug.1995 Issue SIET spa PANTHERS-IC APPARENT TEST RESULT i
TEST TYPE : Shakedown NUMBER : HSD10 TEST DATE : 26 July 1995 TEST OBJECTIVE :
Measure the effect o. small leahge cf Drain Valves F117 and F136 DATA RECORDING PERIOD REFERENCE TEST TIME i
Start :
16:37 Stop :
17:04 Start :
16:37 Stop :
17:04 DATA FILE NAMES i
Historic TH vi.:s:
SH260795.STO TM quantities:
HSDTM10.DAT TH quantities:
HSD10.DAT Vibrations tape n.
not recorded
{
FAILED OR UNAVAILABLE INSTRUMENTS:
F-2001 DP004 L-P001 T-1001 T-1002 5
T-2001 LDT001 LDT002 LDT003 All accelerometers T-QO10 T-Q014 T-Q021 ZERO NOT IN TOLLERANCE INSTRUMENTS :
DF001 DP006 DP026 DP-1001 ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FUi L :
l DP010 DP012 DP-Q005 DP-QOO6 L-Q001 L-Q001 L-1001 OVER RANGE SIGNALS : NONE DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? 'YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
Date Description Prepared by Checked by Approved by Page Of by L.T sch S. Bp P hjasog 1
//
j 01 Aug.1995 Issue Si1v y
SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : Shakedown NUMBER: HSD12 TEST DATE : 26 July 1995 TEST OBJECTIVE :
Verify the adequacy of the facility for IC stan-up tests i
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
18:27 Stop :
19:43 Start :
18:27 Stop :
19:43 DATA FILE NAMES
^
Historic TH values:
SH260795.STO TM quantities:
HSDTM12.DAT TH quantities:
HSD12.DAT Vibrations tape n.
not recorded FAILED OR UNAVAILABLE INSUUJMENTS:
F-2001 DP004 L-P001 T-1001 T-1002 T-2001 LDT001 LDT002 LDT003 All accelerometers T-Q010 T-Q014 T-QO21 ZERO NOT IN TOLLERANCE INSTRUMENTS :
DP001 DP006 DP026 DP-1001 ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL :
DP010 DP012 DP-Q005 DP-Q006 L-Q001 L-QOO1 L-1001 OVER RANGE SIGNALS : NONE DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS :
Loud booms were heard when the drain valve was opened. This is probabily due to a too short valve opening time.
HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
Date Description Prepared by, Checked by Approved by Page Of W LEYrs L g// /(/ilv,efi, _.
S. Bot Pggso 1
iy 27 Sep.1995 Issue i
SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 1 NUMBER: T02 TEST DATE : 27 Sep.1995 TEST OBJECTIVE :
Measure the IC performance in steady-state conditions at fixed inlet pressure.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
12:45 Stop :
13:22 Start :
12:45 Stop :
13:15 DATA FILE NAMES Historic TH values: TH2 70995.STO TM quantities:
T02TM02.DAT TH quantities:
T02TH2.DAT Vibrations tape n.
001 FAILED OR UNAVAILABLE INSTRUMENTS:
T-Q010 T-Q014 T-Q021 DX-A009 DX-B015 DX-BB003 ZERO NOT IN TOLLERANCE INSTRUMENTS :
The zero check is not significant because all lines, pools and tanks were full or in pressure.
ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL :
The zero check is not significant because all lines, pools and tanks were full or in pressure.
OVER ' RANGE SIGNALS :
F-R001 DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
.. = - -..
- t
~
Description Prepared bvt Checked by Approved by Page Of Date
/
/
DV L=TT i: R 27 Sep.1995 Issue inveti S.
P Masoni 1
/y
. n C.
4rs.lua 1
e SIET spa PANTHERS-IC APPARENT TEST RESULT i
TEST TYPE : 1
' NUMBER: T03 TEST DATE : 26 Sep.1995 TEST OBJECTIVE :
Measure the IC performance in steady-state conditions at fixed inlet pressure.
DATA RECORDING PERIOD REFERENCE TEST TIME l
Start :
17:11 Stop :
17:42 Start :
17:11 Stop :
17:42 G)
DATA FILE NAMES l
Historic TH values: TH260995.STO TM quantities:
T03TM01.DAT
]
TH quantities:
T03THl.DAT Vibrations tape n.
001 l
FAILED OR UNAVAILABLE INSTRUMENTS:
T-QO10 T-Q014 T-QO21 DX-A009 DX-B015 DX-BB003 4
l ZERO NOT IN TOLLERANCE INSTRUMENTS :
j DP030 DP-IO01 F-M00 i L-0001 l
P-H00 t 1
j ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL :
DP-Q005 DP-Q006 L-100i L-P001 L-QOO1 4
L-QOO2 DP010 DP011 OVER RANGE SIGNALS : NONE DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES s
HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
Date Description Prepared by Checked by Approved by Page Of tw carru o
S.Bo gsgy 1
?J 25 Sep.1995 Issue gS,il SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 1 NUMBER: T04 TEST DATE : 20 Sep.1995 TEST OBJECTIVE :
Measure the IC performance in steady-state conditions at fixed inlet pressure.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
15:06 Stop :
15:36 Stan :
15:06 Stop :
15:36 g,
DATA FILE NAMES Historic TH values: TH200995.STO TM quantities:
T04TM01.DAT TH quantities:
T04TH1.DAT Vibrations tape n.
001 FAILED OR UNAVAILABLE INSTRUMENTS:
T-QO10 T-Q014 T-QO21 DX-A009 DX-3015 DX-BB003 ZERO NOT IN TOLLERANCE INSTRUMENTS :
The zero check is not significant because all lines, pools and tanks were full or in pressure.
ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL :
The zero check is not significant because all lines, pools and tanks were full or in pressure.
OVER RANGE SIGNALS :
DP-QOO6 DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
Date Description Prepared by Checked by Approved by Pace Of W L'ETTE R givg/,
S.Bo [
25 Sep.1995 Issue i
Jg P Mgs,og 2
g SET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 1 NUMBER : T05 TEST DATE : 20 Sep.1995 TEST OBJECTIVE :
Measure the IC performance in steady-state conditions at fixed inlet pressure.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
13:58 Stop :
14:30 Start :
14:00 Stop :
14:30
-~ 's DATA FILE NAMES Historic TH values: TH200995.STO TM quantities:
T05TM01.DAT TH quantities:
T05THl.DAT Vibrations tape n.
001 FAILED OR UNAVAILABLE INSTRUMENTS:
T-Q010 T-Q014 T-QO21 DX-A009 DX-BOIS DX-BB003 ZERO NOT IN TOLLERANCE INSTRUMENTS :
The zero check is not significant because all lines, pools and tanks were full or in pressure.
ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL :
The zero check is not significant because all lines, pools and tanks were full or in pressure.
i OVER RANGE SIGNALS :
DP-QOO6 DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
date Description Prepared by Checked by Approved by Dare Of l
EY Lh.TTiiW, Rhlvp],y S. Bot gason 1
73 25 Sep.1995 Issue o1E T spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 1 NUMBER: T06 TEST DATE : 20 Sep.1995 TEST OBJECTIVE :
Measure the IC performance in steady-state conditions at fixed inlet pressure.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
12:59 Stop :
13:29 Start :
12:59 Stop :
13:29
[,
DATA FILE NAMES Historic TH values: TH200995.STO TM quantities:
T06TM02.DAT TH quantities:
T06TH2.DAT Vibrations tape n.
001 FAILED OR UNAVAILABLE INSTRUMENTS:
T-Q010 T-Q014 T-Q021 DX-A009 DX-B015 DX-BB003 ZERO NOT IN TOLLERANCE INSTRUMENTS :
The zero check is not significant because all lines, pools and tanks were full or in pressure.
)
ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL :
The zero check is not significant because all lines, pools and tanks were full or in pressure.
OVER RANGE SIGNALS :
DP-QOO6 DEVIATIONS FROM TEST PROCElh1RES : NONE PROBLEMS AND DISFUNCTIONS: NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
,Date Description Prepared by, Checked by Approved by Paec Of hi,1,ve S. B h
n 1
)J 27 Sep.1995 Issue SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 1 NUMBER : T07_.1 TEST DATE : 26 Sep.1995 TEST OBJECTIVE :
Repeat Test T07.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
14:59 Stop :
15:29 Start :
14:59 Stop :
15:29 DATA FILE NAMES Historic TH values: TH260995.STO TM quantities:
T07TM04.DAT TH quantities:
T07TH4.DAT Vibrations tape n.
001 FAILED OR UNAVAILABLE INSTRUMENTS:
T-Q010 T-QO14 T-QO21 DX-A009 DX-B015 DX-BB003 ZERO NOT IN TOLLERANCE INSTRUMENTS :
DP030 DP-IO01 F-M001 L-0001 P-H001 ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL :
DP-Q005 DP-Q006 L-IO01 L-P001 L-Q001 L-Q002 DP010 DP011 OVER RANGE SIGNALS :
DP-Q006 DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
Da're Description Prepargd byl,
Checked by Approved by Page Of O' L Ewh(
/'
fj S. Bohc gasg 1
JJ 07 Aug.1995 Issue IJ ilve g
SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 1 NUMBER : T08 TEST DATE : 02 Aug.1995 TEST OBJECTIVE :
I Measure the IC performance in steady-state conditions at fixed inlet pressure.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
19:26 Stop :
19:57 Start :
19:26 Stop :
19:57 DATA FILE NAMES Historic TH values: TH020895.STO TM quantities:
T08TM01.DAT TH quantities:
T08THl.DAT Vibrations tape n.
001 FAILED OR UNAVAILABLE INSTRUMENTS:
T-1001 T-1002 T-2001 T-Q010 T-Q014 T-QO21 F-2001 ZERO NOT IN TOLLERANCE INSTRUMENTS :
DP030 ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL :
DP010 DP012 DP-Q001 DP-QOO6 L-OOO1 L-P001 L-Q001 OVER RANGE SIGNALS :
DP001 DP-QOO6 DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBIECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
I Date Description Prepared by / 4 Checked by Approved by Pase Of i
07 Aug.1995 Issue j
_h S. Bob son 1 )/
SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 1 NUMBER : T09 TEST DATE : 02 Aug.1995 TEST OBJECTIVE :
Measure the IC performance in sterdy-state conditions at fixed inlet pressure.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
18:11 Stop :
18:42 Start :
18:11 Stop :
18:42 JPy DATA FILE NAMES Historic TH values: TH020895.STO TM quantities:
T09TM01.DAT TH quantities:
T09THl.DAT Vibrations tape n.
001 FAILED OR UNAVAILABLE INSTRUMENTS:
T-1001 T-1002 T-2001 T-Q010 T-Q014 T-QO21 F-2001 ZERO NOT IN TOLLERANCE INSTRUMENTS :
DP030 ZERO NOT CHECKED BECAUSE.0F LINES, TANKS OR POOLS FULL :
DP010 DP012 DP-Q001 DP-QOO6 L-0001 L-P001 L-Q001 OVER RANGE SIGNALS :
DP001 DP-QOO6 DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
Dste Description l Prepared by //
Checked by Approved by.
Page Of sy tem
//
j Rj;S 1,yeg)g..
S.Bo Pgson 1 //
~
07 Aug.1995 Issue J
SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 1 NUMBER : T10 TEST DATE : 02 Aug.1995 TEST OBJECTIVE :
Measure the IC performance in steady-state conditions at fixed inlet pressure.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
17:05 Stop :
17:35 Start :
17:05 Stop :
17:35
^
DATA FILE NAMES Historic TH values: TH020895.STO TM quantities:
T10TM01.DAT
)
TH quantities:
T10TH1.DAT Vibrations tape n.
001 FAILED OR UNAVAILABLE INSTRUMENTS:
T-1001 T-1002 T-2001 T-Q010 T-Q014 T-Q021 F-2001 ZERO NOT IN TOLLERANCE INSTRUMENTS :
DP030 ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL DP010 DP012 DP-Q001 DP-Q006 L-0001 r
L-P00i L-Q001
~
OVER RANGE SIGNALS :
DP-QOO6 DEVIATIONS FROM TEST PROCEDURES : NONE l
PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES j
HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES l
4
3 Date Description Prepared by i.
Checked by Approved by Page Of R S Iver;fh. S.Bo[
bhfasonN#-
1 lJ
$7 Aug.1995 Issue SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 1 NUMBER : Tl1 TEST DATE : 02 Aug.1995 TEST OBJECTIVE :
Measure the IC performance in steady-state conditions at fixed inlet pressure.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
15:37 Stop :
16:07 Start :
15:37 Stop :
16:07 DATA FILE NAMES
^
Historic TH values: TH020895.STO TM quantities:
T11TM02.DAT TH quantities:
T11TH2.D AT Vibrations tape n.
001 FAILED OR UNAVAILABLE INSTRUMENTS:
T-1001 T-1002 T-2001 T-Q010 T-Q014 T-QO21 F-2001 ZERO NOT IN TOLLERANCE INSTRUMENTS :
DP030 ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL :
DP010 DP012 DP-Q001 DP-QOO6 L-0001 L-P00I L-Q001 OVER RANGE SIGNALS : NONE DEVIATIONS FROM TEST PROCEDURES : NONE anw PROBLEMS AND DISFUNCTIONS :
Displacement signals (LVDT) have been acquired in volts.
HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
Date Description Prepared by l
Checked by Approved by Pase I Of 23 Aug.1995 Issue i
. S. Bh P Ma 1
/f SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 4 NUMBER: T14 TEST DATE : 03 Aug.1995 TEST OBJECTIVE :
Measure the effect of pool water level decrease / increase at 0.58 MPa initial pressure.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
11:27 Stop :
19:24 Start :
11:27 Stop :
19:24
^
DATA FILE NAMES Historic TH values: TH030895.STO TM quantities:
T14TM02+10.DAT TH quantities:
T14TH2+10.DAT Vibrations tape n.
001 FAILED OR UNAVAILABLE INSTRUMENTS:
T-1001 T-1002 T-2001 T-Q010 T-Q014 T-QO21 F-2001 ZERO NOT IN TOLLERANCE INSTRUMENTS : NONE ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL :
DP002 DP003 DP004 DP005 DP006 DP008 DP011 DP012 DP010 DP007 DP009 DP020 DP021 DP025 DP027 DP029 DP022 DP023 DP024 DP026 DP028 DP030 DP-Q'O 5 DP-QOO6 L-A001 L-H001 L-IO01 L-OOO1 L-P00i L-Q001 L-QOO2 P-1002 P-A002\\a P-A002\\b P-A003\\a P-A003\\b P B001\\a P-B001\\b P-E001 P-I001 OVER RANGE SIGNALS :
DP001 DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
I
]
Date Description Prepared by i e Checked by Approved by Pase Of 23 Aug.1995 Issue lvef S. B a
1
)/
SIET spa PANTHERS-IC APPARENT TEST RESULT 3
1 TEST TYPE : 4 NUMBER : T15 TEST DATE : 04 Aug.1995 TEST OBJECTIVE :
Measure the effect of pool water level decrease / increase at 2.17 MPa initial pressure.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
10:42 Stop :
17:21 Start :
10:42 Stop :
17:21 DATA FILE NAMES Historic TH values: THM0895.STO TM quantities:
T15TM02+17.DAT TH quantities:
T15TH2+17.DAT Vibrations tape n.
001 FAILED OR UNAVAILABLE INSTRUMENTS:
i T-1001 T-1002 T-2001 T-Q010 T-Q014 T-QO21 F-2001 ZERO NOT IN TOLLERANCE INSTRUMENTS : NONE ZERO NOT CHECKED BECAUSE OF LINES, TANKS OR POOLS FULL :
DP002 DP003 DP004 DP005 DP006 DP008 DP011 DP012 DP010 DP007 DP009 DP020 DP021 DP025 DP027 DP029 DP022 DP023 DP024 DP026 DP028 DP030 DP-Q005 DP-Q006 L A001 L-H00i L-1001 L-OOO1 L-P001 L-QOO1 L-Q002 P-IO02 P-A002\\a P-A002\\b P A003\\a P-A003\\b P B001\\a P-B001\\b P-E001 P IO01 OVER RANGE SIGNALS :
DP001 DEVIATIONS FROM TEST PROCEDURES : NONE I
PROBLEMS AND DISFUNCTIONS :
l i
At apprximately 12:28 when the level in the PCC pool was 1.7 m, a high temperature alarm caused an automatic inlet steam shutdown.
4 HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
.m_.m._
Date Desenption Prepared by i, Checked by Approved by Pare Of R.hiverij
.. S. B (gaso
,05 Sep.1995 Issue I
y SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 6 NUMBER : T17_A TEST DATE : 30 Aug.1995 TEST OBJECTIVE :
Perform Heatup/Cooldown cycles without IC operation at maximum rate of 100*C/ hour
- .nd maximum pressure 8720 kPa.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
11:10 Stop :
15:41 Start :
11:10 Stop :
15:41 DATA FILE NAMES Historic TH values: TH300895.STO TM quantities:
T17TMAl+6.DAT TH quantities:
T17 THAL +6.DAT Vibrations tape n.
not recorded FAILED OR UNAVAILABLE INSTRUMENTS:
T-1001 T-1002 T-2001 T-Q010 T-Q014 T-QO21 F-2001 DX A009 DX-BB003 DX-B015 OVER RANGE SIGNALS :
PO-A002 DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS : NONE l
HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES
l Description l Prepared byl Checked by Approved by Page Of Date fS,ilv S. Bh os sep.1995 Issue s
1
/3 SIET spa PANTHERS-IC APPARENT TEST RESULT TESTTYPE : 6 NUMBER : T17_B TEST DATE : 31 Aug.1995
}
TEST OBJECTIVE :
Perform Heatup/Cooldown cycles without IC operation at maximum rate of 100'C/ hour i
and maximum pressure 8720 kPa.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
10:42 Stop :
15:17 Start :
10:42 Stop :
15:17 "i
DATA FILE NAMES Historic TH values: TH310895.STO TM quantities:
T17TMB 1+11.D AT TH quantities:
T17THB l+11.DAT Vibrations tape n.
not recorded l
FAILED OR UNAVAILABLE INSTRUMENTS:
l T-1001 T-1002 T-2001 T-QO10 T-Q014 T-QO21 F-2001 DX-A009 DX BB003 OVER RANGE SIGNALS : NONE DEVIATIONS FROM TEST PROCEDURES : NONE 1
i I
l PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES 1
l l
J
Date Description Prepared by /
Checked by Approved by Pave Of 05 Sep.1995 Issue R dilve S.Bo a n 1
)J SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 6 NUMBER : T17_C TEST DATE : Ol Sep.1995 TEST OBJECTIVE :
Perform Heatup/Cooldown cycles without IC operation at maximum rate of 100*C/ hour and maximum pressure 8720 kPa.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
10:06 Stop :
15:14 Start :
10:06 Stop :
15:14 DATA FILE NAMES Historic TH values: TH010995.STO TM quantities:
T17TMCl+7.DAT TH quantities:
T17THCl+7.DAT Vibrations tape n.
not recorded FAILED OR UNAVAILABLE INSTRUMENTS:
T-1001 T-1002 T-2001 T-Q010 T-Q014 T-QO21 F-2001 DX-A009 DX-BB003 OVER RANGE SIGNALS NONE DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED 7 YES
Date l Description Prepared by
- i Checked by Approved by Page Of ge/.Sily,etlih,
/
m EY LsXTE ri 05 Sep.1995 Issue S. B gasogg I
l/
SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 6 NUMBER : T17_D TEST DATE : 04 Sep.1995 TEST OBJECTIVE :
Perform Heatup/Cooldown cycles without IC operation at maximum rate of 100*C/ hour and maximum pressure 8720 kPa.
DATA RECORDING PERIOD REFERENCE TEST TIME Stan :
10:23 Stop :
15:23 Stan :
10:23 Stop :
15:23
{}
DATA FILE NAMES Historic TH values: TH040995.STO TM quantities:
T17TMDl+5.DAT TH quantities:
T17THDI+5.DAT Vibrations tape n.
not recorded FAILED OR UNAVAILABLE INSTRUMENTS:
T-1001 T-1002 T-2001 T-Q010 T-Q014 T-QO21 F-2001 DX-A009 DX-BB003 OVER RANGE SIGNALS : NONE DEVIATIONS FROM TEST PROCEDURES : NONE l
PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES 4
Checked by Approved by Paec Of Date Description Prepared by,1 i
b>'g(asg'TEP-ET P.g i
i ff b7 Sep.1995 Issue i}v S. B
/
SIET spa PANTHERS-IC APPARENT TEST RESULT TEST TYPE : 6 NUMBER : T17_.E TEST DATE : 05 Sep.1995 TEST OBJECTIVE :
Perform Heatup/Cooldown cycles without IC operation at maximum rate of 100*C/ hour and maximum pressure 8720 kPa.
DATA RECORDING PERIOD REFERENCE TEST TIME Start :
10:02 Stop :
14:59 Start :
10:02 Stop :
14:59 DATA FILE NAMES Historic TH values: TH050995.STO TM quantities:
T17TMEl+5.DAT TH quantities:
T17 THEL +5.DAT Vibrations tape n.
not recorded FAILED OR UNAVAILABLE INSTRUMENTS:
T-1001 T-1002 T-2001 T-Q010 T-QOJ4 T-QO21 F-2001 DX-A009 DX-BB003 OVER RANGE SIGNALS : NONE DEVIATIONS FROM TEST PROCEDURES : NONE PROBLEMS AND DISFUNCTIONS : NONE HAS THE TEST OBJECTIVE BEEN REACHED ? YES HAVE THE MEASUREMENTS BEEN CORRECTLY RECORDED ? YES l