ML20094D050
| ML20094D050 | |
| Person / Time | |
|---|---|
| Site: | Davis Besse |
| Issue date: | 10/31/1995 |
| From: | Wuokko D CENTERIOR ENERGY |
| To: | Gundrum L NRC |
| Shared Package | |
| ML20094D051 | List: |
| References | |
| NUDOCS 9511030117 | |
| Download: ML20094D050 (1) | |
Text
.
_ _ _ _ _ _ _ _ _ _. _ ~. _
OCT-31 95 09:09 FROM NUCLEAR LZCENSING 419-249-2302 To 3014153861 PACE 02
./
Docket N1Aber 5'0-346 October 31, 1995 License Number NPF-3 l
To:
Linda Gundrum, Davis-Besse Nuclear Power Station Project Manager.
Nuclear Regulatory Commission From: Dale R. Wuokko. Supervisor - Nuclear Regulatory Affairs Unit, Davis-y 2 W Besse Nuclear Power Station 4
l
Subject:
Inadvertent Omission of the Deletion of Technical Specification (TS) 6.9.2.d. " Seismic event analysis" Made During the Submission of License Amendment Request (LAR) 95-0012 LAR 95 0012 (Toledo Edison Letter. Serial Number 2295, dated June 23, 1995) proposed a modification to the Davis Besse Nuclear Power Station (DBNPS)
Operating License NPF-3. Appendix A Technical Specifications to relocate TS 3/4.3.3.3 - Seismic Instrumentation. TF 3/4.3.3.4 Meteorological Instrumen-tation and TS 3/4.4.11 - Reactor Coolat.t System Vents and their Bases.
TS 6.9.2.b Inoperable Seismic Monitoring Instrumentation, and TS 6 ? 2.c -
Inoperable Meteorological Monitoring Instrumentation, Special Remrte, were proposed for deletion from the Technical Specifications due to t1e removal of TS 3/4.3.3.3 and TS 3/4.3.3.4 from the Operating License.
Seismic Event Analysis should also be deleted from the Technical Specifica-tions (as shown in the attached marked up copy of TS page 6 18) due to the relocation of specification 4.3.3.3.2.
This proposed deletion was inadvertently omitted from LAR 95-0012.
Please include the requested deletion of TS 6.9.2.d as part of LAR 95-0012.
The deletion of TS 6.9,2.d will not affect the conclusion in LAR 95-0012 that the proposed changes do not involve a significant hazards consideration.
The deletion of TS 6.9.2.d from the Technical Specifications does not constitute an unreviewed safety question.
Please accept our apology for any inconvenience this may have caused.
01002a I
9511030117 951031 l