NUREG 75/087 M'%

UeS. NUCLEAR RE2ULATGRY COMMIS2 ION

  • 3 STANDARD REVIEW PLAN O

1 OFFICE OF NUCLEAR REACTOR REGULATION N

SECTION 12.3 RADIATION PROTECTION DESIGN FEATURES REVIEW RESPONSIBILITIES Primary - Radiological Assessment Branch (RAB)

Secondary - None I.

AREAS OF REVIEW The following areas of the applicant's safety analysis report (SAR) relating to radiation protection design features are reviewed:

1.

FACILITY DESIGN FEATURES In the preliminary safety analysis report (PSAR)e the description of equipment and a.

facility design features used for assuring that occupational radiation exposures (ORE) will be as low as is reasonably achievable (ALARA).

b.

The radiation zone designationse including zone boundaries for both normal operational and refueling conditions (PSAR and update in the final safety analysis reporte FSAR).

The illustrative examples of facility design features of the equipmente componentse c.

and systems lised in Sections 12.1.3 and 12.3.1 of " Standard Fonnat and Content...."

(Ref. 1) including the scaled layout and arrangement drawings of the facility showing all source locations and the other design details requested in Section 12.3.1 of the " Standard Fonnat...." (PSAR and update in FSAR). Shield wall thicknesses for all shielded spaces should be specified on the drawings or provided in separate tables.

The description of facilities and equipment for handling and use uf sealed and d.

and byproduct materials (PSAR and update in unsealed special nuclear sources s

FSAR).

Information describing implementation of Regulatory Guide 8.8 guidelines on e.

facility and equipment design and layout. Information describing alternativest if such are proposed (PSAD and update in FSAR).

2.

SHIELDING The shielding to be provided for each of the radiation sources identified in SAR a.

Chapter 11 and Section 12.2s including the design criteria for penetrations and the shield material used (PSAR and update in FSAR). (Note item 1.1.c above)

USNRC STANDARD REVIEW PLAN Y T,e$",5YE" DIM *N$eS*a*Uw" rhe,.,"en'~mYe's"tw"YeUee.U 'p~en$et YedYn"$EdI,yUIN

  • i";,:"'
"Je: '",t;'t,e.st':::,0. e.:r.en' "'.::'""e ",". :*e"e.t ents,"0 :e,et :'."J,0;",'t e==,:.O'e:',;".n*

e' "et,' '::,,e:

~~

e,e,e t

,te.t.n.e em.~ e e.

d.ng -,-

ee

,e.

e e,, ewe. te..t e Pwknehed standard rewtow piene intu be revesed perteken,. es appeepelote. to eseemmedete sommente end to refleet new intcemotion and espette seenter Centeneftte end suggestieste fer lenprevement u,ill be eeneidered and shegdd be sent le the U.S Biusteet Regislatory Commiemen.Off ee of N megweenen.vtechington.D.C.20EEE 11/24/75 9511020212 751124

~

PDR NUREG 75/087 R PDR

__. ~. _.. _. _.. _ _ _

b.

Tha description of the methods by which the shield parameters wsre determined, including pertinsnt codes, assumptions, and techniques used or to be used in the calculations (PSAR and update in FSAR).

The description of any special protective features that use shielding, geometric c.

arrangement, or remote handling to assure that ORE will be ALARA (PSAR and update inFSAR).

d.

- Information describing implementation of Regulatory Guides 1,69 and 8.8 (regard-

~

ing special protective features). Information describing alternatives, if such are proposed (PSAR and update in FSAR).

3.

VENTILATION The description of the personnel protection features incorporated in the venti-a.

f ation system design as called for in Section 12.3.3 of " Standard Format and Content..." (PSAR and update in FSAR).

b.

Illustrative example of the air cleaning system design (PSAR and update in FSAR).

Information describing any application of Regulatory Guide 1.52 (particularly c.

Section C 4 & 5) and Regulatory Guide 8.8.

Information describing alternatives, if such are proposed (PSAR and update in FSAR),

4.

AREA RADIATION AND AIRBORNE RADI0 ACTIVITY MONITORING INSTRUMENTATION The description of the fixed area radiation and continuous airborne radioactivity a.

monitoring instrumentation, including in the PSAR the criteria for placement and in the FSAR additional details as called for in Section 12.3.4, " Standard Format and Content.... " for normal operation, anticipated operational occurrences, and accident conditions.

b.

The criteria and method for obtaining representative in-plant airborne radio-activity concentrations (PSAR and update in FSAR).

Information describing the implementation of Regulatory Guides 1.21, 8.2, 8.8 and c.

ANSI N13.1-l%9. Infomation describing alternatives, if such are proposed (PSAR and update in FSAR).

II.

ACCEPTANCE CRITERIA The descriptive information in the SAR is considered to be sufficient if it meets the minimum information needs set forth in Section 12.3 of the " Standard Format and Conten,ts of Safety Analysis Reports for Nuclear Power Plants " Revision 2.

Specific acceptance criteria for these areas of review are as follows:

1.

FACILITY DESIGN FEATURES Acceptability of the facility design features will be based on evidence that the applicant has applied the guidance in Regulatory Guide 8.8 or that alternatives have been proposed. This includes evidence that major exposure accumulating functions (maintenance, refueling, radioactive material handling, processing, etc., in-service inspection and calibration) have been considered in plant design and that potential radiation exposure from these activities will be kept ALARA by radiation protection features incorporatad in the design, including ease of accessibility to work and inspection and sampling areas, the ability to reduce source intensity, design measures 12.3-2 11/24/75

\\

=

to riduce the production, distribution, and retention of activated corrosion products, the ability to reduce time rsquir%d in radiation fields, provision for portable shisid-ing and remote handling tools, etc. Access control will be judged for acceptability in accordance with the requirements of 10 CFR I 20.203.

The areas inside the plant structures, as well as the general plant yard, must be identified by showing radiation areas with acceptable maximum design dose rates and v

Maximum zone dose rate should be defined for each zone, as well as anticipated zones.

occupancy and access control. Acceptance criteria are as follows: The areas that have to be occupied on a predictable basis (number of people and stay or transit times) during nomal operations and anticipated operational occurrences (including refueling; purging; fuel handling and storage; radioactive material handling; processing, use, storage and disposal; normal maintenance; routine operational surveillance; inservice inspection;andcalibration)shouldbezonedsuchthatthisoccupancyresultsinan annual dose to each of the involved individuals that is below the limits of 10 CFR Part 20 and is as low as is reasonably achievable. Based on current operating experi-ence and on predictions made for new plant designs, it is expected that the olant shielding can be designed, the plant can be zoned and sufficient radiation protection design features can be incorporated such that these individuals would receive a small fraction of the 10 CFR Part 20 limit. Whether radiation protection design and zoning is acceptable will be based partly on the actual numbers for average annual radiation exposure to these individuals, determined in the dose assessment required in Section 12.4.

2.

SHIELDING The shielding design is evaluated as to the assumptions used to calculate shield thickness, the calculational method used, and the parameters chosen. There are a number of acceptable shielding calculational codes available for use that are effective for determining the necessary shield thickness for gamma ray sources and for combination Most of the codes used by shield designers have been entered neutron-gama sources.

into the code description file of the Radiation Shielding Infomation Center at Oak Ridge National Laboratory, which means they have been tested and authenticated for operation but not for reliability and accuracy. RAB has three codes in-house for use in shielding calculations. These are SDC, a kernal integration shield design code; G', a general purpose gamma ray scattering program; and MORSE, a general purpose Monte Cario multigroup neutron and gamma ray transport code. SDC can calculate gama ray shielding requirements, handling 13 source geometries (including point, line, disk, plane, slab, and sphere) and with cross sections and materials compositions for 17 mate-rials. As many as 12 gamma ray energy groups, covering the range from 0.1 to 10 MeV, may be used to describe the gama ray spectrum. The staff will use these codes, as necessary, to calculate dose rates for given shield designs and source strengths, as a confirmation of the applicant's method.

The applicant's shielding design is acceptable if the methods are comparable to commonly acceptable shielding calculations and assumptions regarding source terms, cross sections, shield and source geometries, and transport methods are realistic. Acceptable shield-ing codes include but are not limited to ANISN, 00T, MORSE, SAM-CE, 05R. 06R, G',

SDC, l

12.3-3 11/24/75 i

l

and many others. This listing doIs not imply that all thIse codes are equivalent, since some ars much more sophisticatid than others. The staff believes it is advan-tageous to use a good calculational procedure, since an effective shield design is essential to meeting the criteria that occupational radiation exposures will be as low as is reasonably achievable.

Two documents provide additional guidance for acceptability of the shielding design.

.e One is " Reactor Shielding for Nuclear Engineers," Edited by N. M. Schaeffer, published by AEC-0!S 1973." The second is the Stone & Webster Engineering Corporation topical report RP-8 entitled " Radiation Shielding Design and Analysis Ar -oach for Light Water Reactor Power Plants." These documents provide useful guidance regarding radiation shielding design. Some limitations are noted for RP-8, in that the labyrinth entrance ways may not provide dose rates at the outside entrance consistent with area radiation zoning.

In addition, Regulatory Guide 1,69 provides guidance on the fabrication and installation of concrete radiation shields for nuclear power plants. Acceptability of the shield construction will be based on an indication that the guidance of this document has been implemented in the facility construction, or that acceptable alternatives have been proposed. Regulatory Guide 8.8 provides additional acceptance criteria regarding shield-ing and isolation in radiation protection design.

3.

VENTILATION The ventilation system will be acceptable for radiation protection purposes if the cri-teria and bases for ventilation rates within the areas covered in SAR Section 12.2.2 will assure that air will flow from areas of low potential airborne radioactivity to areas of higher airborne radioactivity and then to filters or vents, and that the concentrations of radioactive material in areas normally occupied can be maintained in accordance with the requirements of 10 CFR Part 20. The system shall have adequate capability to reduce concentrations of airborne radioactivity in areas not normally occupied where maintenance or in-service inspection has to be performed, to levels in accordance with the require-ments of 10 CFR I 20.103. The system shall be designed so that filters containing radio-activity can be easily maintained and will not create an additional radiation hazard to personnel in normally occupied areas. Acceptability of the ventilation system, relative to radioactive gases and particulates will also be based on evidence that the applicant has applied the guidance of Regulatory Guide 8.8 or that alternatives have been prepared.

Regulatory Guide 1.52, particularly Sections C.4 and 5, provides guidan;e that can be used in this review, although the guide is written with regard to mitigating accidents involving airborne radioactivity. Good practice in that regard is applicable to normal operation as well, since release of radioactivity in normal operational occurrences is usually different only in quantity from some of the accident cases.

4.

AREA RADIATION AND AIRBORNE RADI0 ACTIVITY MONITORING INSTRUMENTATION The area radiation monitoring instruments will be acceptable if they meet the following criteria:

12.3-4 11/24/75 m

Tha detectors are located in areas and normal access corridors used and occupitd a.

without ristricted access t:hich may have a potential for radiation fields in excess of the radiation zone designation given in Section 12.3.1.

b.

The detectors are sensitive to dose rates that include the design maximum dose rate of the radia+1on zone in which they are located as well as the maximum dose rate for anticipated operational occurrences, Essential instruments are provided with " auxiliary" or emergency power in the y

c.

event of a power failure or postulated accidents. Specific criteria are being developed.

d.

The detectors are calibrated routinely and after any maintenance work is per-formed on the detector. Specific criteria are being developed, Each location has a local audible alarm and variable alarm set points. Monitors e.

located in high noise areas should also have visual alarms.

f.

There is readout and annunciation in the control room.

l The continuous airborne radioactivity monitoring system will be acceptable if it meets the following criteria in addition to the above:

Air is sampled at normally occupied locations where airborne radioactivity is a.

most likely to exist, such as solid waste handling areas, spent fuel pools, reactor operating floors, and BWR turbine buildings, and is detected based on sensitivity of the detection system. Monitoring air being exhausted from loca-tions within the facility is also acceptable during nomal operation, provided

.the monitoring system is capable of detecting one Mpc-hour (particulate or gaseous radioactivity) in any compartment which had a possibility of containing airborne radioactivity and which may be occupied by personnel, b.

Representative air concentrations are measured at the detectors, which are located as close to the sampler intakes as possible.

c.

Ventilation monitors are upstream of HEPA filters.

N Regulatory Guide 1.21. " Measuring and Reporting of Effluents from Nuclear Power Plants,"

provides useful guidance that is applicable to the acceptability of airborne radio-activity monitoring in-plant. Regulatory Guide 8.2, includes guidance on surveys to evaluate radiation hazard. American National Standard ANSI N13.1-1969 provides detailed guidance on sampling airborne radioactive materials in nuclear facilities and may be used for acceptance criteria on the actual sampling process and certain tech-niques involved. Regulatory Guide 8.8 provides guidance on monitoring systems.

111.

REVIEW PROCEDURES The information radiation protection design features furnished in the SAR, including refer-enced parts of Chapters 9 and 11, is reviewed for completeness in accordance with the

" Standard Format and Contents of Safety Analysis Reports for Nuclear Power Plants," Revi-sion 2.

The reviewer evaluates the SAR text and the scaled layout drawings of the facility, concentrating on the sources, shielding, and layouts for the auxiliary building, including the radwaste systems, decontamination facilities, office and access control areas, laundry, lockers and shower rooms, and laboratory facilities; the fuel handling facilities, ieN-ing the spent fuel pool and related equipment; and the BWR turbine building, including 12.3-5 11/24/75

location of stsam linIs, r: heaters, and moisture separators.

For the PSAR this review is particularly concerned with preliminary disign fsaturas which appear to be contradictory to assuring that ORE will be ALARA. In this review, radiation protection design features are evaluated using the guidelines of Regulatory Guide 8.8.

The access control plans are reviewed both tn determine conformance with 10 CFR Part 20 and to determine whether they will control access properly in limited access areas and in restricted access areas (high radiation areas).

The reviewer examines locations of critical controls, valve operating

~

stations, pumps, sample collection stations, inservice inspection locations, radiation moni-tors, control panels, major pipes carrying radioactivity, filters for radioactive liquids j

and gases, and unshielded low level radioactive material storage or processing tanks.He also reviews SAR Chapters 9 and 11 to cover specific details of the fuel handling and stor-j j

age systems, ventilation systems, and radwaste systems as they relate to radiation protection design. Chapter 9 will provide the major description of the mechanical features of venti-lation systems with regard to the venting airborne radioactivity from the plant.

Chapter 9 will also cover major features of the spent fuel pool design, the fuel handling system design and the spent fuel pool cleanup system. Chapter 11 may cover some of the design details of gaseous, liquid and solid radwaste systems that relate to radiation protection.

The reviewer evaluates all aspects of the initial design plans under his areas of review, particularly to identify new arrangements, improved designs, unusual shield thicknesses, a new or modified shield thickness calculational procedure, unusual assumptions in the calculation, placement of radiation monitors, etc.

RAB evaluates the adequacy of the applicant's shielding design on the basis of acceptable radiation shielding codes.

RAB makes a verifying check calculation with SDC, G, or MORSE, 3

l j

whichever is specifically applicable to the situation.

For the FSAR the reviewer considers any changes in the design that might necessitate changes in operating procedures to accomodate a changed radiation zone or a different location of equipment.

The reviewer determines whether the applicant has followed the guidance of the referenced Regulatory Guides and industry standards, both by comparison of the applicant's methods with the information in the guides and by the applicant's reference to any such guides or to alternatives that have been proposed. The reviewer evaluates whether the alternatives are equivalent to or improvements on the methods cited in the referenced Regulatory Guides.

Alternatives that are neither of these are likely to be disapproved.

Based on the review, RAB may request additional information or request the applicant to reevaluate the radiation protection design features to meet the acceptance criteria of Section II.

IV.

EVALUATION FINDINGS The staff's review should verify that adequate and sufficient information is contained in the SAR and amendments to arrive at conclusions of the following type, which are to be included in the staff's Safety Evaluation report. The report will include a sumary of the applicant's coverage, the staff's basis for review and acceptance criteria, and the findings of the review.

The following is a brief representation of the evaluation findings:

12.3-6 11/24/75 e

t u

. ~,-.- -..-- - _.- -.

.~ ~. - ~ -

i "12.3 Radiaticn Protection DIsign Fcaturas "This section of the applicant's SAR has betn reviewed to determine that th3 radiation protection design features of the plant have been designed and provided in a manner that will assure that ORE will be ALARA. The scope of review covers the facility design j

features, the shielding, the ventilation systems, and the radiation monitoring instru-mentation, as they relate to the plant radiation protection design.

v

" Basis for acceptance in the review has been conformance with established guidelines and criteria. The evaluation of the radiation protection design features provides reasonable assurance that it will be possible to operate the facility with ORE that are ALARA.

i "The staff concludes that the protective features provided in the design of r

nuclear plant conform to the Consnission's Regulations, and to applicable Regulatory Guides, and industry standards, and are acceptable."

~

Y.

REFERENCES 1.

Regulatory Guide 1.70, " Standard Format and Contents of Safety Analysis Reports for Nuclear Power Plants," Revision 2.

2.

Regulatory Guide 8.8, "Information Relevant to Maintaining Occupational Radiation Exposure As Low As Practicable."

l 3.

ANSI N13.1 1969, " Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities " American National Standards Institute (1969).

Regulatory Guide 1.69, " Concrete Radiation Shields for Nuclear Power Plants."

i 4.

J 5.

Regulatory Guide 8.2, " Guide for Administrative Pra::tices in Radiation Monitoring."

I 6.

" Reactor Shielding for Nuclear Engineers," N. M. Schaeffer Editor; published by USAEC-0!S 1973.

I 7.

Regulatory Guide 1.52, " Design. Test, and Maintenance Criteria for Atmosphere Cleanup System Air Filtration and Absorption Units of Light Water Cooled Nuclear Power Plants."

Regulatory Guide 1.21, " Measuring and Reporting of Effluents from Nuclear Power Plants."

8.

9.

10 CFR Part 20. " Standards for Protection Against Radiation."

10.

Stone and Webster Topical Report, " Radiation Shielding Design and Analysis Approach for Light Water Reactor Power Plants," RP-8, 1974, 12.3-7 11/24/75 J

.A#4 5

A*AdK-

  1. aMe wJ4.h&,e6dse.-,J 4.ed..

.e.

mm-J-4.

mi4im.m-*d43.h-544414 aFu+

he-J.4E--Me-44.J 4e-d+44id=&esa=*.WE.4 4-% &m.asae--

v i

6 J

j l

l i

l l

J 11/24/75 4