NUREG 75/087 0 8 tog'%
U.S. NUCLEAR REGULATORY COMMISSION
! ~'
STANDARD REVIEW PLAN q
O OFFICE OF NUCLEAR REACTOR REGULATION e
SECTION 9.2.4 POTABLE AND SANITARY WATER SYSTEMS REVIEW RESPONSIBILITIES Primary - Effluent Treatment Systems Branch (ETSB)
Secondary - None I.
AREAS OF REVIEW At the construction permit (CP) stage of review ETSB reviews the information in the s
applicant's safety analysis report (SAR) in the specific areas that follow. At the operating license (0L) stagee ETSB review consists of confirming the design accepted at the CP stage.
1.
The system descriptions for the potable and sanitary water systems (PSWS) are reviewed.
The piping and instrumentation drawings (P& ids) are reviewed at the OL stage.
2.
System design criteria to prevent connection to systems having the potential for con-taining radioactive material are reviewed.
II. ACCEPTANCE CRITERIA ETSB accepts the PSWS design if there are no interconnections between the PSWS and systems N
having the potential for containing radioactive material.
s 111. REVIEW PROCEDURES The reviewer selects and emphasizes material from this review plan as may be appropriate for e
a particular case.
In the review of the PSWSe ETSB considers the design criteria to prevent cross connections e as described in the SAR. The P&ID's are reviewed at the OL stage to verify the absence of interconnections with systems having the potential for containing radioactive materials.
IV. EVALUATION FINDINGS ETSB determines that sufficient infonnation has been provided and that the review supports conclusions of the following types to be included in the staff's safety evaluation report:
USNRC STANDARD REVIEW PLAN
- No" e
"."."sE"[ N "dT[.n.nte"E N D N N N "S Y eUtEYeIn U Y p"u$,N *d N in"*E N eTd d e
,m.t eee g
e.
.a;*':*O',ETe;;m,**,"'e7;;te",'.":r*,'sT!,"'
'*!:.",e*."',fl."'tni-ees one e,t.n7,,e"'e""?,'.0. /.:."e,7.*, e"ee*,*e*nt
- ,f".ee*":'t;:':"':::'0. "o
,e.,e e.
,e, e,,_, n.e et
,wtHlehed etendere ree6ew piens wtII be re. teed pertedneetly. es appeepetete. to eseemmedete sommente end to reflect new informee6en and espeetenee Cesnsnente end suggestiene for isnprovenient will be sentidered end showed be cent te the U $. Nuclear Reguletory Commenenen.Offise of Neeleer Rosete, Reguietsen. Vveehengten. D C. 2055 11/24/75 9511010403 751124 PDR NUREC 75/087 R PDR
"The potablo and sanitary water systems (PSWS) include all components and piping frcm the supply connection to the m iicipal or other water source to all points of discharge to sewage facilities or other plant systems. The scope of review of the PSWS included piping and instrumentation diagrams and descriptive infor-mation for the PSWS. The applicant's proposed design criteria bases for the PSWS have been reviewed.
.c "The basis for acceptance in our review has been conformance of the applicant's designs, design criteria, and design bases for the potable and sanitary water systems to industry standards. Based on the foregoing evaluation, we conclude that the proposed potable and sanitary water systems are acceptable,"
V.
REFERENCES None l
l l
9.2.4 2 11/24/75 l
..