Forwards site-specific Data on Fish Consumption & Dilution Afforded by Receiving Water Body,To Assist in Determining Potential Population Dose Commitment Per NUREG/CR-2850
ML20093H733
Person / Time
Site: Davis Besse 
Issue date: 07/20/1984
From: Murray T
TOLEDO EDISON CO.
To: Willis C
Office of Nuclear Reactor Regulation
References
RTR-NUREG-CR-2850 G84-1475, NUDOCS 8407250256
Download: ML20093H733 (2)


Text

.

4 July 20, 1984 TOLEDO EDISON Charles A. Willis G84-1475 Office of Nuclear Reactor Regulation File: TT 1.4 U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. Willis:

From our review of the NRC report, Population Dose Commitments due to Radioactive Releases from Nuclear Power Plant Sites in 1980, NUREG/CR-2850, we were concerned at discovering that the Davis-Besse Nuclear Power Station (DBNPS) was the third highest of all sites evaluated in the NRC's calculations of the population doses via the liquid pathway. The basis for this concern is that during this same period, DBNPS was 35th in total liquid radioactive material releases (mixed fission and activation products).

We recognize that in an absolute sense, the NRC's calcualtion of 11 man-rem for 1980 for DBNPS is not significant compared to an environmental dose commitment.

However, we are concerned that the NRC correlation of radioactive material releases to population dose.s may be overly conservative, yielding a false representation of the relative environmental impact of the operation of the DBNPS. This over conservatism resulted in the station being required to expand the environmental radiological monitoring program for compliance to the Radiological Effluent Tech-nical Specifications.

As discussed in NUREG/CR-2850, site-specific data is used where available; lacking

-such data, generic assumptions are assumed concerning dilution and exposed popula-tions via the drinking water and fish consumption pathways.

In order to assist the NRC in presenting a more accurate determination of the potential population dose commitment for DBNPS, site-specific data on fish consumption and dilution afforded by the receiving water body are given in the attached Tables 1 and 2.

Fish dilution data were based on compilations and analyses that were performed by the Toledo

Edison Company in demonstrating compliance with the regulatory requirements of 10 CFR 50.34a and 10 CFR 50, Appendix I (refer to the Toledo Edison Company's June 4, 1976 Appendix I submittal to the NRC).

Lusing a weighted average of 1.8 E-4 for the fish dilution factor shown in Table 1, in lieu of the generic assumptions, will yield a more accurate evaluation of the potential population dose commitment attributable to the operation of the DBNPS.

A further reduction in the population dose will result by using the total dilution water for the year as shown in Table 2, rather than using just the dilution water discharged during the release.

If we can be of any further assistance in assuring that the appropriate site-specific parameters are considered by the NRC

/n in their evaluation of the population doses for the DBNPS, please let us know.

Sincerely, rg a mummy /g Terry D. Murray, Station Superintendent IMS Davis-Besse Nuclear Power Station TDM/DWB/lrh g7gg6gg u

Attachment P

PDR I

h cc: ~ D. A. Baker, Battelle W. W. Meinke, USNRC EDlSobL 2A T

T LEO bbN ANY AVENUE TOLEDO OHlo 43652 E-

y 'h ~-:

TABLE 1 COMMERCIAL FISH AND SPORTFISH CATCH DAVIS-BESSE NUCLEAR POWER STATION

  • TYPELOF CATCH LANDING AMOUNT CAUGHT DILUTION FACTOR (LBS) s Commerical Lake Erie 8.42E+06 2.0E-04 Commerical Port Clinton 5.9E+05 2.4E-04 Commerical Sandusky Bay 2.87E+06 9.0E-05 s

Sport-Lake Erie 1.30E+07 2.0E-04 Tctal 2.49E+07 1.8E-04 (1.13E+07 kg)

(weighted average)


..--------------------------------------------------------y-----

TABLE 2 TOTAL ANNUAL DILUTION WATER DAVIS-BESSE NUCLEAR POWER STATION

' YEAR VOLUME (LITERS)

.1981 5.18E+10 1982 3.24E+10 1983' 1.87E+10 t

[

  • hdapted from Davis-Besse Nuclear Power Station, Unit No.1, Evaluation of Compliance with Appendix I to 10 CFR 50, June 4, 1976 L

L

_