Forwards Interim Part 21 Rept Re Calculational Errors for Missile Doors.Initially Reported on 840629.Further Redesign Required to Determine Extent of Exceeding Specified Design Allowables.Next Rept Will Be Submitted by 840801
ML20093E259
Person / Time
Site: Harris, Limerick, 05000000
Issue date: 07/05/1984
From: Godfrey D
WOOLLEY MANUFACTURING DIV.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
REF-PT21-84-320-000 PT21-84-320, PT21-84-320-000, NUDOCS 8407170440
Download: ML20093E259 (3)


Text

(

iS July 5, 1984 Mr..i. G. Keppler, Regional Administrator U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement 799 Roosevelt Road Glen Ellyn, Illinois 60137

Dear Mr. Keppler:

In accordance with the requirements of 10CFR21, I am forwarding herewith a copy of Summary of Calculational Earors For Missile Doors, dated July 5, 1984. The discovery of these errors and potential safety impact was reported by phone to your Mr. R. C. Kanor on June 29, 1984.

The attached summary provides a description of the discovery and evaluation of the calculational errors and the'possible impact upon the design and functional requirements for missile shield doors for the Limerick and Shearon Harris nuclear power plants.

The missile protection doors, as defined in the attached summary, have been designed, fabricated, delivered and partially erected for the referenced nuclear power plants. Neither of the referenced power plants are presently in operation, and therefore, these errors do not presently present a possible safety hazard to the public.

An update of the evaluation of the calculational errors will be submitted on or before August 1, 1984.

If there are any questions, please contact me at our new location, 4413 Kings Run Drive, Cincinnati, Ohio 45232, telephone 513/ 641-0500.

ry truly yours, Q4-

"v c,

Dwaine A. Godfrey Vice President hw enclosures:

2 copies W/ Summary

$bO$$*of$8E8l, PDR

\\

W.J. hiley Co.

1315 West 22nd Street

  • Telephone 312-654-2700
  • TWX 910-651-0235 Answerback WJ WOOLLEY OAKR

r, WJ.Woolley Co.

Summary of Calculational Errors For Missile Shield Doors By W. J. Woolley Company July 5, 1994 On June 25, 1984 a difference in the preliminary designed thickness requirements for missile shield doors for an on going project was discovered to be greater than similar missile shield doors for previous projects designed by another engineering group. This dir-ference was reported to Mr. Dwaine Godfrey, Vice President.

Mr. Godfrey reported this difference to the President of the Company and requested an engineering evaluation to determine if possible engineering errors existed. A review meeting was scheduled on June 27. During this meeting, it was concluded that apparent engineering errors were made on the previous designs and was duplicated on subsequent designs. An immediate review of the design and the affected doors and plants was initiated. The results of this review were reported by phone to Mr. R. C. Kanop of the NRC Regional Office, Chicago on June 29, 1984.

The errors are associated with calculating the plastic moment resistance of a uniform rectangular plate. The plastic moment resistance is then used to verify that the calculated ductility ratio is within the specified limit. A preliminary revic., reveals that the corrected plastic moment capacity results in a ductility ratio greater than the specified limits for some of the missile 'hield doors. Further redesign will be required to determine the extent of exceeding the specified design allowables.

The nuclear power plants and the related missile shield doors are summarized as follows:

I. - Limerick Generating Station, Units 1 and 2 Missile Shield Doors identification numbers 193, 195, 196, 205, 289, 293, 294 II. - Shearon Harris Nuclear Station Missile Shield Doors identification numbers 57, 90. 92. 232, 250, 312, 321, 462, 463 The completion of the design review, redesign and corrective measures, if required, will be dependent upon establishing appropriate modifica-tions for those missile shield doors that fail to comply with the allowable design limits. A summary update will be submitted on or before August 1, 1984.

~

i WJ.Woolley Co.

Summary of Calculational Errors July 5, 1984 Page Two Missile Shield doors are provided usually at openings on safety related structures and prevent the ingress of postulated missiles generated by a tornado. Such a missile is postulated to be a telephone pole, steel pipe, steel rod, lumber or automobile. The specifics are defined in the design requirements and Safety Analysis Report.

Neither of the above referenced plants are in operation and these design errors presently do not present a safety hazard to the general public.

hw