f., .

i c ..

Georgia Power Compary Routta 2. L'ox 299A Wayresboro. Georgia 30830 Telephone 404 554 9%1. Ext 3360 404 724 8114. E vt. 3360 m

D. O. Foster , , n Georgia Power toe r uut%fm ewt c system ce it agar Vogi e Project June 26, 1984 United States Nuclear Regulatory Commission

Reference:

Office of Inspection and Enforcement RII: JP0: ,

Region II - Suite 3100 50-424, 50-425 101 Marietta Street Atlanta, Georgia 30303 File: X7BC24 Log: GN-377  :

Attention: Mr. James P. O'Reilly Gentlemen:

In our letter of March 12, 1984 (File: X7BC24, Log: GN-329),in response to I&E Bulletin 83-07, "Apparently Fraudulent Products Sold by Ray Miller, Inc." the Georgia Power Company indicated that the final re-sults of its investigation of this concern would be submitted to the NRC on or about June 24, 1984. Georgia Power Company has completed its in-vestigation and har concluded that no materials supplied by Ray Miller, Inc. have been used in or provided for safety-related applications at the Vogtle Electric Generating Plant. The investigation is summarized in the attachments..

This response, which completes our actions relative to I&E Bulletin

., 83-07, contains no proprietary information and may be placed in the NRC l

Public Document Room.

Very truly yours',' ' j u/N

. O. Foster' unl~

REF/00F/tdm

\\\

i 7g 1 _

PDR

W y .- .-

J Mr. James P. O'Reilly June 25, 1984 Page Two D. O. Foster states that he is the Vice President and Project General Manager of the Vogtle Electric Generating Plant and is authorized to execute this oath on behalf of Georgia Power Company and that to the best of his knowledge and belief the facts set forth in this , letter are true.

i /

/

/ .

./

GPC: - < - . (r%/ -N D. O. Foster Sworn to and subscribed before me this ,$ 7N day of June, 1984.

ecwi >,3. N eSuk6f.

D

[

MY']COMMISSIONSEXPIRES: [37xE /[/9PR Attachment xc: U. S. Nuclear Regulatory Commission Document Control Desk .

Washington, D.C. 20555 l 0. Batum l J. A. Bailey E. D. Groover L. T. Gucwa M. Malcom G. Bockhold, Jr.

l- P. D. Rice W. F. Sanders W. T. Nickerson i

l t

'I Page 1 of 2 l, Attachment a Investigation for IE Bulletin 83-07

Subject:

IE Bulletin No. 83-07, Apparently Fraudulent Products Sold by Ray Miller, Inc.

Purpose:

Nuclear power reactor licensees were informed in January, 1983 by Information Notice 83-01 that fraudulent products may have been sold to nuclear industry companies by Ray Miller, Inc.

Available information regarding specific purchase orders for which materials were apparently substituted was provided to the licensees in IE Bulletin 83-07 and its two supplements. The licensees were requested to determine where suspect material has been installed in plants, evaluate .its safety significance, and tag or dispose of suspect material not yet installed.

Applicability: The Vogtle Project has made surveys of suppliers to determine whether any apparently fraudulent materials have been received at the VEGP jobsite. Results of the surveys show that material from Ray Miller, Inc., of Decatur, Georgia, was received at the jobsite and that no materials were received from any other Ray Miller source. The material received consisted of the following:

(1) One ten foot section of Schedule 40 S/S 304L, 1-1/4 inch pipe was supplied by Modern Welding Company, Inc.

This material was used in the fabrication of the Auxiliary Building safety-related sump lining assembly but was subsequently scrapped because the sumps failed to meet specification requirements.

(2) Eight 3/4 inch 3000# SCRD couplings tagged 7068; two 6 inch 150#, WNRF 40S, 304 flanges; two 6 inch 90LR 40S 304L elbows; and two 4 inch 90SR, 40S 304L elbows were used in the fabrication of the vacuum degasifier in the Unit 1 Auxiliary Feedwater System (Plant Equip-ment No. 1-1302-04-001-E01). This equipment is non-safety related.

(3) Eight 3/4 inch 3000#, SCRD couplings tagged 7069; two 4 inch 90EL 40S, 304L elbows; and four 4 inch 150#

WNRF flanges were used in the fabrication of the vacuum degasifier in the Unit 1 Reactor Makeup Water Storage Tank and Degasifier System (Plant Equipment No. 1-1228-D4-001-E01). This equipment is non-safety related.

Items (2) and (3) above have been documented in Deviation Report MD-5565. These non-safety related materials were dispositioned and used as-is based on an engineering evaluation that showed the material had been drop-shipped from Tubeline Corporation of Carol Stream, Illinois, to Modern Welding of Decatur, Georgia without any handling by Ray Miller Inc., Decatur, Georgia.

Page 2 of 2 Attachment a Attachment b lists suppliers contacted by the Vogtle Project regarding use and supply of Ray Miller, Inc. material. Each supplier, with the exception of Modern Welding, stated that no such material had been used by them or their suppliers.

The final conclusion is that Ray Miller, Inc., material has not been used in or provided for safety-related applications for the Vogtle Electric Generating Plant.

I

(

l f

I l

L

m

  • l* *l F

!' Page 1 of 4 Attachment b IE BULLETIN 83-07 VENDOR LIST PAV NO.

MFG.-NAME -

SPEC. N0. UNIT 1 UNIT 2 American Air Filter X4AJ06 2101 2-88 American Air Filter X4AJ07 1602 2-80 Ametek-Straza Div. X4AQ10 2702 2-104 Anchor / Darling Industries, Inc. X4AQ56 8664 ----

(Kulpsville,PA)

Anchor / Darling Valve X4AR01 438 2-51 Anchor / Darling Valve X4AR19 1765 2-84 (Williamsport,PA)

Bergen-Patterson Pipe Support, Corp. X4AQ03 471 2-85 Bethlehem Steel X4AQ32 7296 ----

Bethlehem Steel X4AQ32 7297 ----

Bethlehem Steel X4AQ32 10315 ----

Bingham-Willamette Company X4AF02 625 2-67 Chicago Bridge & Iron X2AG07 474 2-63 (Birmingham,AL)

Chicago Bridge & Ircn X3AG14 10075 2-307 (Birmingham,AL)

Chicago Bridge & Iron X4AH03 473 2-61 (Birmingham,AL)

Comsip, Inc. X5AA04 6154 2-250 Comsip, Inc. X5AA05 3020 2-126 Conax X3AB03 3636 2-150 Consolidated Pipe & Supply X4AQ34A 5721 ----

Consolidated Pipe & Supply X4AQ36A 9113 ----

Consolidated Pipe & Supply X5AG15A 7165 ----

L_

m Page 2 of 4 I- Attachmenfb IE BULLETIN 83-07 VENDOR LIST PAV N0.

MFG. SPEC. NO. UNIT 1 UNIT 2 Control Components Inc. -

X5AC13 2783 2-110 Crosby Valve & Gage Co. X5AC05 466 2-54 CVI X4AJ16 1907 2-86 Dieterich Std. Corp. X5AG14 2858 2-111 Dragon Valve Company X5AG08 3412 ----

Dresser Industries X4AR06 443 2-49 FMC Corporation X2AD03 5205 ----

(Colmar, PA)

Fisher Control Company X5AC01 370 2-42 (Marshalltown,PA)

Fisher Control Company X5AC03 206 2-34 (Marshalltown,PA)

Flow Tech Corp. X5AG02 2722 2-109 General Atomic X4AF26 5752 2-264 Goulds Pump, Inc. X4AJ05 1552 2-77 HUB, Inc. X4AQ34 5010 ----

HUB, Inc. X4AQ36 6517 ----

HUB, Inc. X4AQ36 5309 ----

Ingersoll-Rand Co. X4AF01 485 2-64 Ingersoll-Rand Co. X4AF03 486 2-65 ITT-Barton Instrument X5AD07 8449 2-293 Johnson Controls, Inc. X4AJ20 5898 2-240 Johnson Controls, Inc. X5AG19 10316 ----

Johnston Pump Company X4AF04 2300 2-95 Kerotest Valve X4AR23 3957 2-169 Kappers Company, Inc. ------

1021 ----

Magnetrol International, Inc. X5AF02 2718 2-105 L

fl.'

' Page 3 of 4

[, Attachment b IE BULLETIN 83-07 VENDOR LIST PAV NO.

MFG. SPEC. N0. UNIT 1 UNIT 2 The Marley Co. ~

X4A002 119 2-32 I

McQuad Perfex X4AE01 865 2-69 Metal Bellows Corporation X5AG16 6061 2-246 Modern Welding ------

2039 ----

Monsanto ------

775 ----

NPS Industries X4AQ29 3958 2-170 Pacific Scientific Co. X4AQ18 1608 2-81 PPG Industries, Inc. ------

1489 ----

Pyco, Inc. X5AE06 2568 2-99 Pullman Power Products X4AQ01 20 2-20 Process Supplies, Inc. ------

3423 ----

Process Supplies, Inc. X5AG17 6433 ----

Process Supplies, Inc. X9AC04 6857 Process Supplies, Inc. ------

7265 ----

Reliance Electric X5AB01 426 ----

Richmond Engineering Co. X4AH04 470 2-57 Richmond Engineering Co. X4AH04 2859 2-112 Rockwell International X4AR04 1372 2-74 (Carpentersville,ILL)

Rockwell International X4AR17 1334 2-71  !

(Raleigh,NC) f Rockwell International X4AR34A 5754 2-266 (SulpherSprings,TX)

Rosemount, Inc. X5AD04 3369 2-138 (Minneapolis,MN) X5AD05 3369 2-138 Sandvik X5AG15A 7165 ----

5

f. t . .,,-

Page 4 of 4 Attachment b IE BULLETIN 83-07 VENDOR LIST PAV NO.

MFG. SPEC. N0. UNIT 1 UNIT 2 Techno Corporation X4AR27 4763 2-194 (Erie,PA)

The Trane Company X4AJ04 1609 2-82 Transamerica Delaval, Engine & X4AK01 481 2-60 Compressor Div.

Transamerica Delaval, Gems Sensors Div. X5AF05 2979 2-122 Vacco X4AN06 2143 2-90 Valcor Manufacturing Company X5AC07 2459 2-97 Whiting Corporation X4ALO1 1595 2-79 W. R. Grace (Raychem) X3AJ11 4006 ----

Xertex Corporation X5AA03 3379 2-141 Yarway Corporation X4AR34B 5753 2-265 Zurn Industries, Inc. X4AW05 6423 2-262 Westinghouse Power Corporation 2 2-2 l

l i

l l

l