Text
- - -
l l
TECHNICAL EVALUATION REPORT RADIOLOGICAL EFFLUENT TECHNICAL SPECIFICATION IMPLEMENTATION (A-2)
PHILADELPHIA ELECTRIC COMPANY PEACH BOTTOM ATOMIC POWER STATION UNITS 2 AND 3 NRC DOCKET NO. 50-277, 50-278 FRC PROJECT C5506 NRC TAC NO. 8044, 8122 FRC ASSIGNMENT 4 NRC CONTRACT NO. NRC-03-81-130 FRC TASKS 108, 109 Prepared by Franklin Research Center Author: C. Fernandez 20th and Race Streets Philadelphia, PA 19103 FRC Group Leader: S. Pandey Prepared for Nuclear Regulatory Commission Washington, D.C. 20555 Lead NRC Engineer: F. Congel C. Willis June 29, 1983 This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, or any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for any third party's use, or the results of such use, of any information, appa-ratus, product or process disclosed in this report, or represents that its use by such third party would not infringe privately owned rights.
Prepared by:
Reviewed by:
Approved by:
$41, w
/
/
/
Principal uthor Group Leader
/
- epartrnerf Director
/
D M
N&8 Date:
Date:
Date:
4
. Franklin Research Center A Division of The Franklin Institute The Benwrmn Frankhn Perm sy. PMa. Ps 19103 (215)448 1000
.V/)
u
TER-C5506-108/109 CONTENTS Section Title Page 1
INTRODUCTION 1
1.1 Purpose of Review.
1 1.2 Generic Background.
1 1.3 Plant-Specific Background.
3 2
REVIEW CRITERIA.
5 3
TECHNICAL EVALUATION 7
3.1 General Description of Radiological Effluent System 7
3.2 Radiological Effluent Technical Specifications.
9 3.3 Offsite Dose Calculation Manual
. 18 4
CONCLUSIONS.
23 5
REFERENCES.
25 1
111 NT%M2~-~ncS&n~n
TER-C550 6-108/109 FIGURES Number Title Page 1
Liquid Radwaste Treatment Systems, Effluent Paths, and Controls for Peach Bottom Atomic Power Station Units 2 and 3 8
2 Gaseous Radwaste Treatment Systems, Effluent Paths, and Controls for Peach Bottom Atomic Power Station Units 2 and 3 10 TABLE Number Title page 1
Evaluation of Proposed Radiological Effluent Technical Specifications (RETS), Peach Bottom Atomic Power Station Units 2 and 3 24 4
J I
iv L
ter
TER-C550 6-108/109 FOREWORD This Technical Evaluation Report was prepared by Franklin Research Center under a contract with the U.S. Nuclear Regulatory Commission (Office of Nuclear Reactor Regulation, Division of Operating Reactors) for technical assistance in support of NBC operating reactor licensing actions. The technical evaluation was conducted in accordance with criteria established by the NBC.
i 6
E v
A
t
\\
e TER-C5506-108/109 1.
INTRODUCTION z
'l.1 PURPOSE OF REVIEW The purpose of this technical evaluation report (TER) is to review and evaluate the proposed changes in 'the Technical Specifications of Peach Bottom Atomic Power Station Units 2 and 3 with regard to Radiological-Effluent Technical-Specifications (RETS), the Offsite Dose Calculation Manual (ODCM),-
and the Process Control Program (PCP).
The evaluation uses criteria proposed by the NRC staff in the Model Technical Specifications for boiling water reactors (BWRs), NUREG-0473 (1).
This effort is directed toward the NRC objective of implementing RETS which comply principally with the regulatory requirements of the Code of Federal Regulations, Title 10, Part 50 (10CFR50), " Domestic Licensing of Production and Utilization Facilities," Appendix I (2]. Other regulations pertinent to the control of effluent releases are also included within the scope of compliance.
1.2 GENERIC BACEGROUND Since 1970,10CFR50, 'Section 50.36a, " Technical Specifications on Effluents from Nuclear Power Reactors," has required licensees to provide technical specifications which ensure that radioactive releases will be kept as low as reasonably achievable (ALARA).
In 1975, numerical guidance for the ALARA requirement was issued in 10CFR50, Appendix I [3].
The licensees of all-operating reactors were required to submit, no later than June 4,1976, their proposed ALARA Technical Specifications and information for evaluation in accordance with 10CFR50, Appendix I.
However, in February 1976, the NBC staff recommended that proposals to modify Technical Specifications be deferred until the NRC completed the model RETS. The model RETS deals with radioactive waste management systems and environmental monitoring. Although the model RETS closely parallels 10CFR50, Appendix I requirements, it also includes provisions for addressing other issues. UDDPhn.,
i TER-C5506-108/109 These other issues are specifically stipulated by the following regulations:
o 10CFR20 [4], " Standards for Protection Against Radiation," Paragraphs j
20.105 (c), 20.106 (g), and 20.405 (c) require that nuclear power plants and other licensees comply with 40CFR190 [5], " Environmental Radiation Protection Standards for Nuclear Power Operations," and submit reports to the NBC when the 40CFR190 limits have been or may be exceeded.
o 10CFR50, Appendix A [6], " General Design Criteria for Nuclear Power Plants," contains Criterion 60 - Control of releases of radioactive materials to the environment; Criterion 63 - Monitoring fuel and waste storage; and Criterion 64 - Monitoring radioactivity releases.
l o 10CFR50, Appendix B [7], establishes the quality assurance required 4
for nuclear power plants.
The NBC position on the model RETS was established in May 1978 when the NBC's Regulatory Requirements Review Committee approved the model RETS:
NUREG-0473 [1] for BWRs and NUREG-0472 for pressurized water reactors (PWRs)
[8]. Copies were sent to licensees in July 1978 with a request to submit proposed site-specific RETS on a staggered schedule over a 6-month period.
Licensees responded with requests for clarifications and extensions..
The Atomic Industrial Forum (AIF) formed a task force to comment on the model RETS.
NBC staff members first met with the AIF task force on June 17, 1978.
The model RETS was subsequently revised to reflect comments from the I
AIF and others. A principal change was the transfer of much of the material concerning dose calculations from the model RETS to a separate ODCM.
The revised model RETS was sent to licensees on November 15 and 16,1978 with guidance (NUREG-0133 [9]) for preparation of the RETS and the ODCM and a new schedule for respcnses, again staggered over a 6-month period.
Four regional seminars on the RETS were conducted by the NBC staff during November and December 1978.
Subsequently, Revision 2 of the model RETS and additional guidance on the ODCM were issued in February 1979 to each utility at individual meetings.
In response to _ the NRC's request, operating reactor licensees subsequently submitted initial proposals on plant RETS and the ODCM.
Review leading to ultimate implementation of these documents was initiated by the NBC in 1981 using subcontracted independent teams as reviewers.
! fjanklin Resge I
ter-
l l
l 1
TER-C550 6-108/109 As the RETS reiiew process has progressed since September 1981, feedback from the licensees has led the NRC to believe that modification to some of the guidelines in the current version of Revision 2 is needed to clarify specific concerns of the licensees and thus expedite the entire review process.
Starting in April 1982, NRC distributed revised versions of RETS in draf t form to the licensees during site visits. The new guidance on these changes was presented at the AIF meeting on May 19, 1982 [10].
Some interim changes regarding the Radiological Environmental Monitoring Section were issued in August 1982 (11]. With the incorporation of these new changes, NRC issued, in 4
Septemher 1982, a draf t version of NUREG-0472, Revision 3 [12], to serve as new guidance for the review teams.
Since the equivalent version of NUREG-0473 for BWRs has not been made available by the NBC, the Licensee-submitted BWR RETS were evaluated largely against the provisions specified by NUREG-0473, Revision 2 [1]. Updated provisions common to both BWRs and PWRs, as specified by Reference 12, were also adopted for the review.
In addition, some changes made specifically to BWRs [13] were also included as added guidance.
1.3 PLANT-SPECIFIC BACKGROUND In response to the NRC's request, the Licensee, Philadelphia Electric Company (PECO), submitted a RETS proposal dated March 1,1979 [14] on behalf of Peach Bottom Atomic Power Station Units 2 and 3, which included an ODCM submittal. The Licensee's RETS submittal did not follow the model RETS format (NUREG-0473) for BWRs.
In an initial evaluation by the Franklin Reseach Center (FRC), an independent review team, the Licensee's RETS and ODCM submittals were evaluated against the model RETS (NUREG-0473, Revision 2) and assessed for compliance with the stipulated provisions. Copies of the draf t review, dated June 1, 1992 [15, 16), were delivered to the NRC and the Licensee prior to a site visit by the reviewers.
The site visit was conducted on June 29-30, 1982 by the reviewers with the participation of PECO personnel and the NRC staf f.
Discussions focused on the initial review of the proposed changes to the RETS and on the technical evaluation of the ODCM.
The deficiencies in the Licensee's proposed RETS were Fjanklinjesearch Center t
TI:R-C5506-108/109 considered, deviations from NRC guidelines were pointed out, many differences were clarified, and a few items remained unresolved pending justification by the Licensee. These issues are summarized in Reference 17.
The final ver sion of the Peach Bottom RETS and ODCM [18], dated November 29, 1982, was submitted to the NIC and transmitted to the FRC reviewers together with justifications provided by the Licensee. A PCP was not included in the submittal. Final evaluation of RETS was detailed in a comparison report [19] which used NUREG-0473, Revision 2 [1], the updated generic provisions specified by the draf t version of NUREG-0472, Revision 3 [12], and f
provisions specific to BWRs [13] to evaluate the Licensee's submittal.
The comparison report also incorporates NRC comments [20, 21] which serve as additional staff positions regarding plant-specific issues.
0 ranidin Resear
-w ch Center
TER-C550 6-100/109 2.
REVIEW CRITERIA Review criteria for the RETS and ODCM were provided by the NBC in three documents:
NUREG-0472, RETS for PWRs NUREG-0473, RETS for BWRs NUREG-0133, Preparation of RETS for Nuclear Power Plants.
Twelve essential criteria are given for the RETS and ODCM:
1.
All significant releases of radioactivity shall be controlled and monitored.
2.
Offsite concentrations of radioactivity shall not exceed the 10CFR20, Appendix B, Table II limits.
3.
Offsite radiation doses shall be ALARA.
4.
EquipmentshallbemaintainedandusedtokeepoffsitedosesALARh.
5.
Radwaste tank inventories shall be limited so that failureb will not cause of fsite doses exceeding 10CFR20 limits.
6.
Hydrogen and/or oxygen concentrations in the waste gas system shall be controlled to prevent explosive mixtures.
7.
Wastes shall be processed to shipping and burial ground criteria under a documented program, subject to quality assurance verification.
8.
An environmental monitoring program, including a land-use census and an interlaboratory comparison program, shall be implemented.
9.
The radwaste management program shall be subject to regular audits and reviews.
10. Procedures for control of liquid and gaseous effluents shall be maintained and followed.
11.
Periodic and special reports on environmental monitoring and on releases shall be submitted.
12.
Offsite done calculations shall be performed using documented and approved methods consistent with NRC methodology. 4%
Ubd Banklin Research Center
TER-C550 6-108/109 Subsequent to the publication of NUREG-0472 and NUREG-0473, the NBC staff issued guidelines [22, 23], clarifications [24, 25], and branch positions [26, 27, 28, 29] establishing a policy that guides the licensees of operating reactors to meet the intent, if not the letter, of the model RETS provisions.
The NBC branch positions issued since the RETS implementation review began have clarified the model RETS implementation for operating reactors.
Review of the ODCM was based on the following NBC guidelines Branch Technical Position, " General Content of the Offsite Dose Calculation Manual"
[30]; NUREG-0133 [9]; and Regulatory Guide 1.109 [31].
The ODCM format is lef t to the licensee and may be simplified by tables and grid printouts.
4 i
I
/
i i
t
. Center
TER-C5506-108/109 3.
TECHNICAL EVALUATION 3.1 GENERAL DESCRIPTION OF RADIOLOGICAL EFFLUENT SYSTEM This section briefly describes the liquid and gaseous effluent radwaste treatment systems, release paths, and control systems installed at Peach Bottom Atomic Power Station Units 2 and 3; both units are BWRs.
3.1.1 Radioactive Liquid Effluent Major releases of liquid effluents from the Peach Bottom Station are discharged via the liquid radwaste effluent line (Figure 1).
This effluent path handles the majority of the radioactive discharges; the effluents are normally collected, processed, and monitored before being released in batches. Other potential effluent lines are the main service water line, the emergency service water lines, the high pressure service water line, and the turbine building sumps.
Radioactive liquid wastes are discharged into the Susquehanna River through the circulating water discharge canal if the concentration of radioactive materials is within the allowable limits.
A diagram of the liquid effluent release paths indicating the location of the liquid effluent monitors is shown in Figure 1.
The radioactive liquid wastes originating from the primary drains, equipment drains, chemical wastes, floor drains, and laundry drains are processed through filters and demineralizers prior to release.
These wastes are monitored and controlled by the liquid radwaste effluents radiation monitor. As a safety measure, the liquid radwaste radiation monitor is provided with automatic termination of release upon a high-concentration alarm signal.
Potential leakage of radioactive material into the service water effluents and emergency service water effluents is monitored by gross activity radiation monitors. The high pressure service water effluents are an insignificant source of radioactive material discharge and therefore are not monitored.
i 1 Fyranklin,ReseMter
5 WJ f%
rg LIQUID RADWASTE SYSTEM (UNITS 2 AND 3) oE h
PRIMARY DRAINS INLET
^
mixed BED p3 COLLECTOR FILTER DEMINERAll2ER WASTE SAMPLE
^
TANK Y
g TANK EQUIPMENT DRAedS f--
g 7
iO l
a" R
~
s
,y CONDENSATE s
j RECYCLE h STORAGE TANK CHEMICAL WASTES h FLOOR DRAIN FLOOR DRAIN COLLECTOR FILTER SAMPLE TANK TANK FLOOR DRAINS %
8 LAUNDRY LAUNDRY DRAINS DRAIN FILTER 5
TANK CIRCULATING WATER DISCHARGE CANAL g RM SERVICE WATER e l
j (UNIT 2) 8 SERVICE WATER t I
(UNIT 3) 8 RM
-l EMERGENCY SERVICE WATER '
g tri (UNITS 2 AND 3)
HGH PRESSURE I SERVICE WATER 8 ui (UNMONITORED) un (UNITS 2 AND 3)
TO ENVIRONMENT IW RM = RADIATION MONITOR N
H Figure 1.
Liquid Radwaste Treatment Systems, Effluent Paths, and o
Controls for Peach Bottom Atomic Power Station Units 2 and 3
^
--^
TZR-C5506-108/109 3.1.2 Radioactive Gaseous Effluent A waste gas holdup system is provided for each unit of the Peach Bottom plant. The processed gases from each unit.are routed to the plant main stack for dilution and elevated release to the atmosphere (Figure 2). The radwaste treatment system includes the 3-day (nominal) delay line and HEPA filter fcr each unit.
A diagram showing the location of radioactive gaseous effluent monitors and process equipment is shown in Figure 2.
Gaseous effluents originating from the main condenser offgas, the gland seal exhaust, and the standby gas treatment system are discharged through the plant main stack. Redundant radiation monitors are provided at the main stack to monitor effluent l
releases.
The waste gas holdup system is provided with two hydrogen monitors downstream of the recombiners to prevent the possibility of explosive gas mixture concentrations. Ventilation exhaust releases from the reactor building ventilation exhaust, turbine building ventilation exhaust, radwaste building ventilation exhaust, and the recombiner building ventilation exhaust are released through the reactor building vents. The Unit 2 and Unit 3 reactor building vents are provided wius redundant effluent radiation monitors and are considered ground-level releases in dose calculations.
3.2 RADIOLOGICAL EFFLUENT TECHNICAL SPECIFICATIONS The evaluation of the Licensee's proposed RETS against the provisions of NUREG-0473 included the following (1) a review of information provided in the Licensee's March 1,1979 submittal [14], (2) the resolution of problem areas in that submittal by means of a site visit [17], and (3) a review of the Licensee's November 29, 1982 submittal (18].
3.2.1 Effluent Instrumentation i
The objective of the RETS with regard to effluent instrumentation is to ensure that all significant releases of radioactivity are monitored. The RETS specify that all effluent monitors be operable and alarm / trip setpoints be determined to ensure that radioactivity levels do not exceed the maximum g eseareg ter
=
I l
TER-C550 6-108/109 MAIN STACK u
RM RM MM CONDENSER OO 00 HOLOUP PtPE MAIN CONDENSER I O
l SJAE (UNIT 2)
(S DAYS g
DELAY) l CONDENSER I
s MECHANICAL L
VACUUM
-q PUMP g
i MOLOUP PIPE OLAND SEAL I T
(UN4 2)
M1MOUR DELAY)
RM RM MM CONDENSER HOLOUP PIPE MAIN CONDENSER I
^
~>
RECOMBINER l [3g (30AYS DELAY) l CONDENSER l
l MECHANICAL L_
vACuuu PUMP g
i HOLOUP PtPE GLAND SEAL e t
(UNIT 3) e
(<1 HOUR DELAY)
~STANOSY t
GAS TREATMENT I
(UNITS 2 AND 3) h pg REACTOR 8 LOG EXHAUST % ENT REACTOR 8 LOG (ROOF TOP RE'. EASE)
(UNIT 2) i TUR81NE SLOG 1 (UNIT 2) e RA0 WASTE SLOG t (UNIT 2)
I A
REACTOR BLOG MA DMAUST VENT RM (ROOF TOP RELEASE)
RE R 8W l
,, (UNIT 3) r TURSINE SLOG _ t (UNIT 3) 6 RECOMBINER l BLOG RM = RA0tATiON MONITOR (UNIT 3)
H
- NYOROGEN MONITOR Figure 2.
Gaseous Radwaste Treatment Systems, Effluent Paths, and Controls for Peach Bottom Atomic Power Station Units 2 and 3 CN
TER-C5506-108/109 permissible concentration (MPC) set by 10CFR20. To further ensure that the instrumentation functions properly, surveillance requirements are needed in the specifications.
3.2.1.1 Radioactive Liquid Effluent Monitoring Instrumentation In Section 3/4.3.8.B of the Licensee's submittal, a commitment is made to monitor and control all significant liquid effluent releases to the environment. A liquid radwaste effluents radiation monitor is provided with an associated flow monitor and automatic control function to isolate a high radioactive release discharge. The effluent monitor has appropriate alarm / trip setpoints and. is demonstrated to be operable by performance of surveillance operations consistent with the model RETS (12). Although 1 technical specifications are not provided for the service water system effluent radiation monitor, the Licensee states in the Updated Final Safety Analysis Report that the service water system has a radiation monitor to detect potential radioactive leakage into the environment. - The Licensee states that there are no outside liquid holdup tanks which require tank level indicating devices as specified in the model RETS (12).
The radioactive liquid effluent monitoring instrumentation meets the intent of NUREG-0473.
3.2.1.2 Radioactive Gaseous Effluent Monitoring Instrumentation In Section 3/4.3.8.C of the Licensee's submittal, a commitment is made to monitor and control all significant gaseous effluent release paths. The main stack monitor and the reactor building exhaust vent monitor are provided for this purpose.
The condenser air removal system is equipped with the steam jet air ejector monitor to measure offgas release rate prior to input to the waste gas holdup system.
Redundant hydrogen monitors are provided downstream of the recombiners in the waste gas holdup system to detect the possibility of an explosive gas mixture concentration as specified in the model RETS (12).
These monitors are demonstrated to be operable by performance of surveillance operations, and therefore the radioactive gaseous effluent monitoring instru-mentation meets the intent of NUREG-0473. -
TER-C5506-108/109 3.2.2 Concentration and Dose Rates of Ef fluents 3.2.2.1 Liquid Effluent Concentration In Section 3/4.8.B.1 of the Licensee's submittal, a commitment is made to maintain the concentration of radioactive liquid effluents released to unrestricted areas to within 10CFR20 limits, and, if the concentration of liquid ef fluents exceeds these limits, the concentration will be restored without delay to a value equal to or less than the MPC specified in 10CFR20.
All batches of radioactive liquid effluents from the waste sample tanks are sampled and analyzed in accordance with a sampling and analysis program which meets the intent of NUREG-0473. Continuous releases om the emergency service water and main service water systems are not sampled on a periodic basis. The Licensee, however, states in the Updated Final Safety Analysis Report that the main service water system has a radiation monitor to continuously monitor the service water effluent discharges. This technical specification is consistent with the intent of NUREG-0473.
3.2.2.2 Gaseous Effluent Dose Rate In Section 3/4.8.C.1 of the Licensee's submittal, a commitment is made to maintain the offsite dose rate from radioactive gaseous effluents to areas at and beyond the site boundary within 10CFR20 limits, or the equivalent dose rate values prescribed by Section 3.11.2.1 of NUREG-0473.
If the dose rate of gaseous effluents exceeds these limits, it will be restored without delay to a value equal to or less than these limits.
This commitment satisfies the provisions of NUREG-0473.
The radioactive gaseous waste sampling and analysis program (Table 4.8.2 of the Licensee's submittal) provides adequate sampling and analysis of the main offgas atack and reactor building vent exhaust stack, and therefore meets the intent of NUREG-0473.
3.2.3 of fsite Doses from Ef fluents The objective of the RETS with regard to offsite doses from ef fluents is to ensure that of fsite doses are kept ALARA and are in accordance with
' phb] Frankhn Rewarch r'.ne.,
w
~
i TER-C5506-108/109 o
10CFR50, Appendix I, and 40CFR190.
The Licensee has made a commitment to (1) meet the quarterly and yearly dose limitations for liquid effluents, per Section II.A of Appendix I, 10CFR50; (2) restrict the air doses for beta and gamma radiation in unrestricted areas as specified in 10CFR50, Appendix I,Section II.B; (3) maintain the dcse level at and beyond the site boundary from release of iodine-131, iodine-133, tritium, and all radionuclides in particulate form with' half lives greater than 8 days within the design objectives of 10CFR50, Appendix I,Section II.C; and (4) limit the annual dose from radioactive materials from the plant to any member of the public to within the requirements of 40CFR190.
Since Unita 2 and 3 havw a shared
. radwaste treatment system and common effluent release points, the Appendix I dose commitment limits proposed by the Licensee for the combined effluent release from Units 2 and 3 are twice the design objective contained in Appendix I for one unit.
In each pertinent section, the Licensee has made a commitment to perform dose calculations in accordance with methods given in the ODCM. These offsite dose specifications satisfy the intent of NUREG-0+73.
3.2.4 Effluent Treatment The objectives of the RETS with regard to effluent treatment are to ensure that wastes are treated to keep releases ALARA and to satisfy the provisions of Technical Specifications governing the maintenance and use of radwaste treatment equipment.
The Licensee has made a commitment to use the liquid radwaste treatment systems (Section 3/4.8.D.4 of the Licensee's submittal) when the projected dose, averaged over 31 days, exceeds 25% of the annual dose design objectives, prorated monthly.
Due to a shared liquid treatment system common to Units 2 and 3, the proposed projected dose limits are twice the design objective limits for one unit. For gaseous radwaste, the Licensee e
proposes to treat the effluents by operating the waste gas holdup system whenever the steam jet air ejector is in operation. The Licensee's existing gaseous radwaste treatment system includes a nominal 3-day offgas holdup line and a HEPA filter.
The Licensee has also made a commitment to use the ventilation exhaust treatment system when the projected monthly dose exceeds the limits specified by NUREG-0473.
The Licensee has also made a commitment b EJE@@B3S?teId3 Center
TER-C5506-108/109 in the ODCM to calculate the projected dose on a monthly basis.
It is determined that the Licensee's proposal meets the intent of NUREG-0473.
3.2.5 Radioactivity Inventory Limits The objective of the RETS with regard to the liquid tank inventory limits is to ensure that the rupture of a radwaste tank would not cause offsite doses greater than the limits set in 10CFR20 for nonoccupational exposure. Also, the gasecas radioactivity release inventory is to be limited to within a rate of 100 microcuries per second per megawatt thermal during the operation of the main condenser air ejector.
The Licensee states that there are no outside liquid holdup tanks to which the model RETS (12] Technical Specification 3.11.1.4 applies. For radioactive releases from the main condenser air ejector, a release rate limit of 320,000 microcuries/sec has been set for noble gases, which is based on the rated thermal power of 3293 MWt at both Peach Bottom Units 2 and 3.
The Licensee's proposed technical specification with regard to radioactivity inventory and release rate limits satisfies the intent of NUREG-0473.
3.2.6 Explosive Gas Mixtures The objective of the RETS with regard to explosive gas mixtures is to prevent hydrogen explosions in waste gas systems. The main condenser offgas system is not designed to withstand a hydrogen explosion.
The Licensee has, therefore, made a commitment to maintain a safe concentration of hydrogen in the main condenser offgas system using redundant hydrogen monitors downstream of the recombiners to detect the possibility of an explosive gas mixture concentration.
This commitment satisfies the intent of NUREG-0473.
3.2.7 Solid Radwaste SysteA The objective of the RETS with regard to the solid radwaste system is to ensure that radwaste will be properly processed and packaged before it is shipped to the burial site.
Specification 3.11.3 of NUREG-0473 provides for the establishment of a PCP to show compliance with this obje~ctive. The mklin Research Center
~
1 TER-C5506-108/109 Licensee has made a commitment to implement such a program in accordance with a PCP and to thus ensure that radwaste is properly processed and packaged before it is shipped to the burial site. This meets the intent of NUREG-0473.
3.2.8 Radiological Environmental Monitoring Program The objectives of the RETS with regard to environmental monitoring are to ensure that (1) adequate and full-area-coverage (land and water inclusive) monitoring program exists; (2) the requirements of 10CFR50, Appendix I for technical specifications on environmental monitoring are satisfied; and (3).
the Licensee maintains both a land-use census and interlaboratory comparison program.
In all cases, the Licensee has followed NUREG-0473 guidelines,
' including the Branch Technical Position dated November 1979 [27], and has provided an adequate number of sample locations for pathways identified. The Licensee's methods of analysis and maintenance of yearly records satisfy the NRC guidelines and meet the intent of 10CFR50, Appendix I.
The Licensee ha,s also made a commitment to document the environmental monitoring sample locations in the ODCM, which meets the intent of NUREG-0473. The specifica-tion for the land use census satisfies the provisions of Section 3.1.2.2 of l
NUREG-0473 by providing for an annual census in the specified arean..
The Licensee participates in an interlaboratory comparison program approved by the NRC and reporta the results in the Annual Radiological Environmental Operating Report, which also meets the intent of NUREG-0473.
3.2.9 Audits and Reviews The objective of the RETS with regard to audits and reviews is to ensure that audits and reviews of the radwaste and environmental monitoring programs are properly conducted. The Licensee's administrative structure designates the Plant Operation Review Committee (PORC) and the Operation and Safety Review Committee (OSRC) as the groups responsible for the review and audit of the radiological environmental monitoring program and the ODCM. The PORC is responsible for reviewing the procedures associated with these programs. The n 3- -.
m.--
TER-C5506-108/109 l
OSRC is responsible for auditing the program as of ten as.is specified under NUBEG-0473.
3.2.10 Procedures and Records The objective of the RETS with regard to procedures is to satisfy the written procedures specified in NUREG-0473 for implementing the ODCM, the PCP,
and the quality assurance (QA) program.
It is also an objective of RETS to properly retain the documented records in relation to the environmental monitoring program and certain QA procedures. The Licensee has made a commitment to establish, implement, and maintain written procedures for the PCP, ODCM, and QA program according to the updated provisions of model RETS
[12].
The Licensee intends to retain the records of the radiological environmental monitoring program for the duration of the facility operating license.
It is determined that the Licensee has met the intent of NUREG-0473.
3.2.11 Reports The objective of the RETS with regard to administrative controls is to ensure that appropriate periodic and special reports are submitted to the NBC, and that these reports meet the requirements of 10CFR50.36a.
3.2.11.1 Routine Reports In Section 6.9.3 of the Licensee's submittal, a commitment is made to provide the NHC with an annual radiological environmental operating report that includes summaries, interpretations, and statistical evaluation of the results of the environmental surveillance program.
The report also includes a summary of the radiological environmental monitoring program, the results of the land use censuses, and the results of Licensee participation in an interlaboratory comparison program specified by Specification 3.12.3 of NU REG-0473.
Section 6.9.3 of the Licensee's submittal also states the Licensee's commitment to provide semiannual radioactive effluent release reports which t
{
er
4 TER-C550 6-108/109 include a summary of radioactive liquid and gaseous effluents and solid waste released and a list of unplanned releases.
A list of new locations for dose calculations identified by the land use census and changes to the ODCM are also included in the report. The semiannual radioactive effluent release reports will be submitted within 60 days af ter January 1 and July 1 of each year. The Licensee also proposes to submit an annual radiation dose assessment report within 120 days after January 1 of each year, which will include an annual summary of meteorological data and an assessment of the radiation doses due to the radioactive liquid and gaseous effluents released.
3.2.11.2 Non-Routine Reports In the Licensee's submittal, a commitment is made to provide a special report (according to Section 6.9.2 of the Licensee's submittal) for each of the following in NUREG-0473:
o exceeding liquid effluent dose limits specified in Specifications 3.11.1.2 and 3.11.1.3 o exceeding gaseous effluent dose rate limits specified in Specifications 3.11.2.2, 3.11.2.3, and 3.11.2.4 o exceeding total dose limits specified in Specification 3.11.4 o measured levels of radioactivity in an environmental sampling medium determined to exceed the reporting level of Table 3.12.2.
These reporting commitments meet the intent of NUREG-0473.
3.2.12 Implementation of Major Programs One objective of the administrative controls is to ensure that implementation of major programs such as the ODCM, PCP, and major changes to the radioactive waste treatment system follows appropriate administrative procedures.
The. Licensee has made a commitment to review, report, and implement major programs such as the ODCM, PCP, and major changes to the radioactive waste treatment system. This commitment meets the intent of NUREG-0473. O
. R%m....
s-
TER-C5506-108/109 3.2. 13 Design Features The objective of the RETS with regard to design features is to provide a map of the site area defining the site boundary and unrestricted areas within the site boundary, as well as defining points of release for liquid and gaseous effluents and points where liquid effluents leave the site. The Licensee has provided a satisfactory map of the site.
3.3 OFFSITE DOSE CALCULATION MANUAL (ODCM)
As specified in NUREG-0473, the ODCM is to be developed by the Licensee to document the methodology and approaches used to calculate offsite doses and maintain the operability of the effluent systems.
As a minimum, the ODCM should provide equations and methodology for the following topics:
o alarm and trip setpoint on effluent instrumentation o liquid effluent concentration in unrestricted areas o gaseous effluent dose rate at or beyond the site boundary o liquid and gaseous effluent dose contributions o liquid and gaseous effluent dose projections.
In addition, the ODCM should contain flow diagrams defining the treatment paths and the compcnents of the radioactivo liquid, gaseous, and solid waste management systems. These diagrams should be consistent with the systems being used at the station. A description and location of samples in support of the environmental monitoring program are also needed in the ODCM.
3.3.1 Evaluation The Licensee has followed the methodology of NUREG-0133 [9] to determine the alarm and trip setpoints for the liquid effluent monitors, which ensures that the maximum permissible concentrations, as specified in 10CFR20, will not be exceeded by discharges from various liquid or gaseous release points. To augment conservatism in the case of simultaneous releases, the Licensee has introduced a conservative factor of 10 for liquid effluent setpoint calcula-nklin Research Center
TER-C550 6-108/109 4
tions.. The Licensee, however, has not provided a method to calculate gaseous effluent setpoints.
The Licensee demonstrated the method of calculating the radioactive liquid concentration by describing in the ODCM the means of collecting and
-analyzing representative samples prior to and after releasing liquid effluents into the circulating water discharge.
The method provides added assurance of compliance with 10CFR20 for liquid effluent releases.
Methods are also included for showing that dose rates at or beyond the site boundary due to noble gases, iodine-131, tritium, and particulates with half-lives greater than 8 days are in compliance with 10CFR20.
In this calculation, the Licensee has considered effluent releases from the main stack and the exhaust vents from Unita 2 and 3; the release from the main stack is treated as elevated level,- whereas those from the exhaust vents are at the mixed level.
In all cases, the Licensee has used the highest annual average values of relative concentration (X/Q) and relative deposition (D/Q) to determine the controlling locations. For elevated releases from the main stack, the Licensee has also considered the direct exposure constant (B) from exposure to the finite plume.
The Licensee intends to use the maximally exposed individual and the critical organ as the reference receptor. The Licensee has demonstrated that the described methods and relevant parameters have followed the conservative approacn provided by NUREG-0133 and Regulatory Guide 1.109.
However, since the Licensee has not included iodine-133 in the sampling analysis program, a statement should be added to record the method to account for iodine-133 in the dose rate calculation. Also, for dose rate calculations, the Licensee should consider the predominant pathway from inhalation rather than the ingestion pathways from ground-plane deposition.
In addition, the validity of using the Licensee's code (MARE) to calculating the exposure constant (B) needs to be substantiated.
The cumulative dose is evaluated to ensure that the quarterly and annual dose design objectives specified in RETS are not exceeded.
For liquid releases, the Licensee has identified fish and drinking water consumption as the two viable pathways.
In the calculation, the Licensee has '
]
)Lv+g>--reses--,
i TER-C550 6-108/109 used near-field and far-field dilution factors specific to the plant; all other key parameters follow the suggested values given in Regulatory Guide 1.109.
As in the case of dose rate calculation, the Licensee has used the maximally exposed individual as the reference receptor.
However, the Licensee has not included the drinking water pathway in deriving the dose factors as shown in Table II.A.1 of the proposed ODCM. Fur thermore, the Licensee has not provided a method to project the monthly dose as needed to determine the operation of the radwaste treatment system.
Evaluation of the cumulative dose from noble gas releases includes both beta and gamma and air doses at and beyond the site boundary. The critical organs under consideration are the total body and skin for gamma and beta radiation, respectively. Again, the Licensee has used the maximum (X/Q) values as discussed earlier and has followed the methodology and parameters of NUREG-0133 and Regulatory Guide 1.109.
For iodine-131, tritium, and particulates with half-lives greater than 8 days, the Licensee has provided a method to demonstrate that cumulative doses calculated from the release meet both quarterly and annual design objectives.
The Licensee has demonstrated a method of calculating the dose using maximum annual average (X/Q) values for the inhalation pathway and han included (D/Q) values for the food and ground-plant pathways, as well as the exposure constant (V) for the gamma radiation from the elevated finite plume, which is consistent with the methodology of NUREG-0133. As in the case for dose race calculation, the Licensee should also record the method used to account for iodine-133 in the dose calculation. Also, the Licensee should provide background documents to validate the use of the company code (MARE) to arrive at the exposure constant (V).
Using the existing methodology for gaseous and liquid dose calculations, the Licensee has demonstrated a procedure to determine the monthly dose and to ensure that the design objectives for the liquid radwaste system and the ventilation exhaust system are not exceeded.
The Licensee has not provided diagrams defining the effluent paths and components of the radioactive liquid and geneous waste treatment systems, in nklin Remmarch ('ent c
TER-C550 6-108/109 which the radiation monitors specified in the Licensee-submitted RETS are also to be properly identified.
Tne Licensee has provided a description of sampling locations in the ODCM and has identified them in Table VI.A.1 and also in Figures VI.A.3 through VII. A.3 of that document. This description is consistent with the sampling locations specified in the Licensee's RETS Table 3.12.1-1 on environmental monitoring, except that the Licensee has not designated a scale for Figures VI. A.1 through VI. A.3.
In summary, the Licensee's ODCM uses documented and approved methods that are consistent with the methodology and guidance in NUREG-0133, and therefore is an acceptable reference, except for the following deficiencies:
1.
The Licensee has not addressed the following sections:
The monthly dose projection for the purpose of operating the o
liquid radwaste treatment system.
o Gaseous release setpoint calculations.
o Effluent flow diagram (s) for liquid and gaseous radwaste* system and effluent controls.
2.
The Licensee has not incorporated the drinking water pathway into the dose factor calculation (Table II.A.1 in the ODCM submittal),
although the drinking water pathway has been identified as a viable pathway (Table 4.8.3.a of the RETS submittal).
3.
The Licensee has not provided supporting documentation to validate tha use of its proprietary code (MARE) for calculating the dose contribution of the finite plume from the elevated stack release.
4.
The Licensee has not iceluded iodine-133 in the gasecus dose and dose rate calculations.
5.
The Licensee has not identified and used the inhalation pathway as the. majcr pathway for dose rate calculation from iodines and particulates.
6.
The Licensee has not provided an isotopic analysis method for gaseous dose calculation, as in the case for the liquid dose calculation.
7.
The Licensee has not identified specific pathways (mile, vegetation, etc.) for iodine and particulate dose calculation. nklin RM @gny
t TER-C5506-108/109 8.
The Licensee has not designated a scale for Figures VI.A.1, VI.A.2, and VI.A.3 for environmental monitoring sample locations.
I i
i 1
j.
I I
1 1
i I
i i
anidn Raamarch Center
~
TER-C550 6-108/109 4.
CONCLUSIONS Table 1 summarizes the results of the final review and evaluation of the submittal for the Peach Bottom Atomic Power Station Units 2 and 3 proposed Radiological Effluent Technical Specifications (RETS).
The following conclusions have been reached:
1.
The Licensee's proposed Radiological Effluent Technical Specifications (RETS) submitted November 29, 1982 meet the intent of NUREG-0473, " Radiological Effluent Technical Specifications."
2.
The Licensee's Offsite Dose Calculation Manual (ODCM) submitted on November 29, 1982 uses documented and approved methods and is consistent with the criteria of NUREG-0133, and therefore is an acceptable reference except for the deficiencies listed in Section 3.3.1 of this TER.
O nklin
-_Research Center
c=
' gg?
E:P 5-E5' Table 1.
Evaluation of proposed Radiological Ef fluent Technical Specifications (RETS),
23 Peach Botten Atomic Power Station Units 2 and 3 fr TEChnica l, Speci f !Ca t ions
()
NRC Staff Model Replaces or Updates RETS HUREG-0473 Licensee Proposal Existing Tech. Spec.
{
RETS Requirement (Section)
(Section)
(Section)
Evaluation Effluent Instrumentation 3/4.3.3.10, 3/4.3.3.11 3/4.8.B.3, 3/4.8.C.4 3/4.8.B.4, 3/4.8.C.1 Meets the intent 3/4.8.C.5 of NRC criteria 3/4.8.C.6 3/4.8.C.7 3/4.8.C.8 Radioactive Effluent 3/4.11.1.1, 3/4.11.2.1 3/4.8.B.1, 3/4.8.C.1 3/4.8.B.1, 3/4.0.B.3 Meets the intent Concentrations 3/4.8.C.3, 3/4.8.C.2 of NRC criteria Offsite Doses 3/4.11.1.2, 3/4.11.2.2, 3/4.8.B.2, 3/4.8.C.2, 3/4.8.B.2, 3/4.8.8.7 Meets the intent 3/4.11.2.3, 3/4.11.4 3/4.8.C.3, 3/4.8.D 3/4.8.C.3, 3/4.8.C.4 of HRC criteria
/,
Effluent Treatment 3/4.11.1.3, 3/4.11.2.4 3/4.8.B.4, 3/4.8.C.5 3/4.8.B.5, 3/4.8.C.9 Meets the intent a.
of HRC criteria 1
Radioactivity 3/4.11.1.4, 3/4.11.2.6 3/4.8.C.7 3/4.8.B.6, 3/4.8.C.5 Meets the intent Inventory Limits of NRC criteria Expl'sive cas Mixtures 3/4.11.2.5 3/4.6.C.6 3/4.8.C.10 Meets the intent o
of NRC criteria Solid Radioactive Waste 3/4.11.3 3/4.8.F Not addressed Meets the intent of NRC criteria Environmental Monitoring 3/4.12.1 3/4.8.E 6.4 (Appendix B)
Meets the intent of HRC criteria
>3 Audits and Reviews 6.5.1, 6.5.2 6.5.1, 6.5.2 6.5.1, 6.5.2 Meets the intent of HRC criteria u.
Procedures and Records 6.8, 6.10 6.8, 6.10 6.8, 6.10 Meets the intent c) of NRC criteria y%
W Reports 6.9.1.11, 6.9.1.12, 6.9 2, 6.9.3 6.9.2, 6.9.3 Meets the intent 6.9.2 of NRC criteria
%s '
c$
Implementation of 6.13, 6.14, 6.15 6.17, 6.18 Not addressed Meets the intent 43 Major Programs of HRC criteria.
TER-C5506-108/109 5.
REFERENCES 1.
" Radiological Effluent Technical Specifications for Boiling Water Reactors," Rev. 2 NRC, July 1979 NURL'9-0473 2.
Title 10, Code of Federal Regulations, Part 50, Appendix I, " Numerical Guides for Design Objectives and Limiting Conditions for Operation to Meet the Criterion, 'As Low As Is Reasonably Achievable,' for Radioactive Material in Light-Water-Cooled Nuclear Power Reactor Effluents" 3.
Title 10, Code of Federal Regulations, Part 50, Appendix I,Section V,
" Effective Dates" 4.
Title 10, Code of Federal Regulations, Part 20, " Standards for Protection Against Radiation" 5.
Title 40, Code of Federal Regulations, Part 190, " Environmental Radiation Protection Standards for Nuclear Power Operations" 6.
Title 10, Code of Federal Regulations, Part 50, Appendix A, " General Design Criteria for Nuclear Power Plants" 7.
Title 10, Code of Federal Regulations, Part 50, Appendix B, "Qdality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants" 8.
" Radiological Effluent Technical Specifications for Pressurized Water Reactors," Rev. 2 NRC, July 1979 NUREG-0472 9.
" Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants, A Guidance Manual for Users of Standard Technical Specifications" NBC, October 1978 NUREG-0133 10.
C. Willis and F. Congel (NBC)
" Summary of Draf t Contractor Guidance of RETS" Presented at the AIF Environmental Subcommittee Meeting, Washington, DC May 19, 1982 11.
F. Congel (NRC)
Memo to RAB Staff (NRC)
Subject:
Interim Changes in the Model Radiological Ef fluent Technical Specifications (RETS)
August 9,1982 Mesearch CGC m
TER-C5506-108/109 12.
" Radiological Effluent Technical Specifications for Pressurized Water Reactors," Rev. 3, Draft 7',
intended for contractor guidance in reviewing RETS proposals for operating reactors NRC, September 1902 NUREG-0472 13.
W. Meinke (NBC)
Memo to M. Strum (Yankee Atomic Electric Company)
Subject:
BWR-Specific Changes for NUREG-0472/3, Rev. 3 September 20, 1982 14.
E. J. Bradley (PECO)
Letter to H. R. Denton (NBC)
Subject:
RETS and ODCM Submittal March 1, 1979 15.
" Comparison of Specification NUREG-0473, Radiological Effluent ".'echnical Specifications for BWRs, vs. Licensee Submittal of Radiological Effluent Technical Specifications for Peach Bottom Atomic Power Station Units 2 and 3" (Draft)
Franklin Research Center, June 1, 1983 16.
Technical Review of Offsite Dose Calculation Manual for Peach Bottom Atomic Power Station Units 2 and 3 (Draft)
Franklin Research Center, June 1, 1983 17.
Franklin Research Center Letter of Transmittal to NRC
Subject:
Trip report on site visit to Peach Bottom Atomic Power Station Units 2 and 3 July 30, 1982 18.
E. J. Bradley (PECO)
Letter to H. R. Denton (NBC)
Subject:
RETS and ODCM Submittal November 29, 1982 19.
" Comparison of Specification NUREG-0473, Radiological Effluent Technical Specifications for BWRs, vs. Licensee Final Submittal, dated November 29, 1982, of Radiological Ef fluent Technical Specifications for Peach Bottcm Atomic Power. Station Units 2 and 3" Franklin Research Center, June 29, 1983 23.
W. Meinke (NRC)
Memo to S. Pandey (FRC)
Subject:
NRC Resolution of RETS Review Questions May 10, 1983 l
. nklin Research Center
TER.-C5506-108/109 21.
W. Meinke (NRC)
Memo to S. Pandey (FRC)
Subject NRC Resolution of RETS Review Questions June 13,1983 22.
C. Willis (NRC)
Letter to Dr. S. Pandey (FRC)
Subject:
Changes to RETS requirements following meeting with Atomic Industrial Forum (AIF)
November 20, 1981 23.
C. Willis (NRC)
Letter to Dr. S. Pandey (FRC)
Subject:
Control of explosive gas mixture in PWRs December 18, 1981 24.
C. Willis and F. Congel (NRC)
" Status of NRC Radiological Effluent Technical Specification Activities" Presented at the AIF Conference on NEPA and Nuclear Regulations, Washington, D.C.
October 4-7, 1981 25.
C. Willis (NRC)
~
Memo to P. C. Wagner (NRC)
" Plan for Implementation,of RETS for Operating Reactors" November 4,1981 26.
W. P. Gammill (NRC)
Memo to P. C. Wagner (NRC)
" Current Position on Radiological Effluent Technical Specifications (RETS) Including Explosive Gas Controls" October 7, 1981 27.
"An Acceptable Radiological Environmental Monitoring Program" Radiological Assessment Branch Technical Position, Revision 1 November 1979 28.
W. P. Gammill/F. J. Congel (NRC)
Memo to ETSB/RAB (NRC)
" Radiological Effluent Technical Specifications (RETS) Provisions for I-133" November 29, 1982 29.
Methods for Demonstrating LWR Compliance with the EPA Uranium Fuel Cycle Standard (40CFR190)
NRC, February 1980 NUREG-0543
. i l
I 1
TER-C5506-108/109 30.
" General contents of the Of fsite Dose Calculation Manual," Revision 1 Branch Technical Position, Radiological Assessment Branch February 8, 1979 31.
Calculation of Annual Doses to Man from Routine Releases of Reactor Ef fluents for the Purpose of Evaluating Compliance with 10CFR50, Appendix I NRC, October 1977 Regulatory Guide 1.109, Revision 1 r
l I
(
l
. O M _____________