1)

SHAW, PITTMAN, POTTs & TROWBRIDGE A PARTNEmSMir Or PeoFES$iONAL ComPOmATIONS b

ISOO M STREETe N. W.

J J M *-

WASHINGTON. D. C. 20036

(

1 DEBomAH SER MemTMA SCONE mowAN*

%'"*"N A "w%'EE EEO"eih

' ret /

mAMSAY D. POTTS. P C.

JOHN ENGEL

  • C.

= v.- m.,. 3 5?o%^aYrYIm'"w"^ MMS Pc E'MA"m?IS"m"Ei"*aIO! EE L

O

=,1 ~. : w n

,~-.E m cha a ="ac-

- -. ~..

= m = "N

= =el:"= r

==a"c.:ean~m wx::PC..

ROeg n? E. ZANLE N. # C.

SETH M. MOOG AStA TRAvig 7.SMOWN.Jm.

La e

WAY i

E Ps EN s' M

N GEORGE M mOGE RS. JR US$11 "C%R"SW.L.c.

2^1',fS",."#4*v"E M%A"zSC.

ai""o'OAE*NT",.i.m a

!^at".^ " M.M*h C

8 M De ANDER. F C.

E EN M L

.1 pAMELA M AhoERSON V'CTOM8A J. PE mMINS.

  • C.

(202)822s072 FmEotmeCM L. mLEW

,g MAmTtN O. MmALL, P C.

ELL E N A. FARDEL LAumENCE w COMEN CMamQ J Amm NO J

m J A G egg Y. E'PST N.

C J VE $L E G,

JE FFEnv L. VAeLON. P C.

M A E L' A S gem sansARA M. ROSSOTTI. P C.

dOLAND M

M E

            • ($"'*'^****)

o"A.e" % "WEv ik%"f%"$'LSTEi RASN m'

RCMan GALEpe RAU"tTJ'P"h!Ed h. P.e. hM*2",L"AS"!"thi! "

MANNAME M LEBEmMAN CAv 0 m S mhE ST L. SLAN J

P C.

LL AM P BAmm JUOiTM A SANDLEm C. SOWOOvN TRA*N CARLETON S JONE S. P C.

CManLES H. MONTANGE JOMN F. OCALT*

E S

N w

GA L m'CMam0 A. SAMP mENNETH o awe meACM MN.' A 4.

AM M symGEm P C SME LDON J. WEtSEL. P.C.

PM8 LIP J. ManVEY C

m ManO G cyDe my q

$ *[*$NS "EYdAhrh C.

e mA Ad. Mom EN PETER J FEmmanA stCMAmo 4,a.gECNEm COuteSEL wiLeERT WASHINGTON II SONNET S. GOTTLet S MELEN TomELU SYEVEN L. ME LT2E n. P.C.

MOwAmo M. SMAFFERMAN

  • esor aces trao see o C OE.W o AULtCM. P C.

June 27, 1984 WRITE M S DinECT O'AL 8eusseE m (202) 822-1051 BY FEDERAL EXPRESS HAND DELIVERED Dr. David L. Hetrick Sheldon J. Wolfe Administrative Judge Administrative Judge Atomic Safety and Licensing Board Chairman, Atomic Safety and Professor of Nuclear Engineering Licensing Board U.S. Nuclear Regulatory University of Arizona Tucson, Arizona 85271 Commission Washington, D.C.

20555 BY FEDERAL EXPRESS Dr. James C. Lamb, III Administrative Judge Atomic Safety and Licensing Board 313 Woodhaven Road Chapel Hill, North Carolina 27514 In the Matter of Metropolitan Edison Company, Et A1.

(Three Mile Island Nuclear Station, Unit No. 1)

Docket No. 50-289-OLA and ASLBP 83-491-04-OLA (Steam Generator Repair)

Dear Administrative Judges:

For the information of the Hearing Board and the parties, I am enclosing a copy of a letter sent today by Licensee 8406290379 940627 PDR ADOCK 05000289 G

PDR n

^C 7 gy

T L

' CHAW, PITTMAN, PoTTs & TROWBRIDGE A pamTNERSMip OF pmOFEttecesAL CON 80eAftONS Sheldon J. Wolfe Dr. David L.~Hetrick Dr. James C. Lamb, III June 27, 1984 Page Two to the NRC staf f reporting on steam generator leakage recently detected at TMI-1.

Sincerely, h

CAucCsill tw St2 e

Bruce W. Churchill i BWC/pp Enclosure Service List cc:

L_

I UNITED. STATES OF AMERICA NUCLEAR REGULATORY COMMISSION 1

Before the Atomic Safety and Licensing Board i

In the Matter of

)

)

METROPOLITAN. EDISON COMPANY, ET AL. )

Docket No. 50-2 8 9-OLA

)

ASLBP 83-491-04-OLA (Three Mile. Island Nuclear

)

(Steam Generator Repair)

Station, Unit No. 1)

)

1 SERVICE LIST Sheldon J. Wolfe 1

Atomic Safety and Licensing Board Panel Administrative Judge Chairman, Atomic Safety and

.U.S. Nuclear Regulatory Commission

-Licensing Board Washington, D.C.

20555 U.S. Nuclear Regulatory

, Docketing : and Service Section (3)

Commission Washington, D.C.

20555 Office of the Secretary U. S'. Nuclear Regulatory Commission l Dr. David L.

Hetrick

. Washington, D.C.

20555 Administrative Judge Jodnne,Doroshow, Esq.

Atomic Safety and Licensing B6ard Professor of-Nuclear Engineering.

Louise Bradford University of Arizona l~

-Three Mile Island Alert, Inc.

Tucson, Arizona 85271 7+

3151Peffer Street

'Harrisburg, Pennsylvania 17102 Dr. James C.

Lamb, III Jane Lee Administrative Judge Atomic Safety and Licensing Board 183 Valley Road Etters, Pennsylvania 17319 313 Woodhaven Road Chapel Hill, North Carolina 27514

'i 3

Norman Aamodt s

Richard J.

Rawson, Esq.

R. D.

5, dox 428.

Coatesville, Pennsylvania 19320 Mary E. Wagner, Esq.

Office of' Executive Legal Director.

U.S. Nuclear Regulatory Commission' Washington, D.C.

20555 3

s Atomic Safety and-Licensing Appeal Board Panel U

U.S. Nuclear Regulatory Comission

(

t Washington, D.C.

20555

9 h

GPU Nuclear Corporation

e"a

=PU luclear Middletown, Pennsy!vania 17057 0191 717 944 7621 TEl.EX 84 2386 Writer's Direct Olal Number:

t 5211-84-2161 June 21, 1984 l

r t

Office of Nuclear Reactor Regulations

~

John F. Stolz, Chief Attn:

Operating Reactors Branch No. 4-U. S. Nuclear Regulatory Comission Washington, D.C. 20555

Dear Mr. Stelz:

Three Mile Island Nuclear Station, Unit I (TMI-1)

Operating License No. OPR-50 Docket No. 50-289 THI-1 Steam Generator Leakage Testing This letter is to provide you with additional infonnation now availab l

the condition of the TMI-1 steam generators.

As you are aware, secondary chemistry data are routinely monit evaluated for trends at TMI-1 as part of our steam genera d to tritium concentrations, as well as slight decreases in pH, were foun monitoring program.

The leak indicate a small increase in leakage in the "B" steam generator.

ld RCS rate was determined to be approximately 1.5 gph under the cu conditions (about'300 psig).

l conditions indicates a primary-(to-secondary leak rate bel l

administrative limit of 7 gphsph), additional investigations of th conducted.

Bubble tests of tubing above approximately the eleventh tube s One tube (80-45) have been conducted in the "A" and "B" steam generators.

f Tube in the "B" steam generator was identified as bubbling significantly.

By 80-45 has bubbled slightly and intermittantly during past bubble te using stoppers at various levels in the bubbling tube, it has been determined that primary coolant can pass through a crack ver i

upper tube sheet, then down through the tight tube-to-tubeshee I

idiaryof the General Public Utilities Corporation t

I

' 5211-84-2161 Mr. John F. Stolz i

Some leakage via comprising the new joint, and into the secondary system.

l tub.e-to-tubesheet such pathways has always been predicted for the mechan ill be joints.

plugged before return to service.

i fibroscope.

Additional inspection of the leaking joint is planned us ng a l d to identify l

Drip tests of the "B" lower tubesheet area are also schedu e i

s of the steam significant leakage contributors, if any, in the lower reg o t from lower in planned as confirmation that leakage is past the joint, no f other generator.

While the ECT equipment is in place, a sample populat the tube.

tubes will also be monitored.

this week or early next week.

i 14 other In the course of performing the highly sensitive bubble test ng,le, ver faintly visib tubes, 6 plugged and 8 unplugged were seen to haveSeven tubes were in t h mis.try "A" OTSG (which had no evidence of a leakt.ge increa slight bubble formation.

i This type of leakage past the tube-to-tubesheet joint in all cases. eptable and monitoring).

bubbling has been seen in past tests, and is considered to be acc sion and the not unexpected for mechanical joints such as the kinetic expanN ial observation mechanical rolled plug.these tubes, but their locations have been noted fo during any future bubble tests.

l ted, GPU has Subject to review as further testing and examinations are comp e f the steam generators concluded that earlier evaluations of acceptability ofo Sincerely.

H.D.Hukkl1 Directce

'J-1 HDH/MJG/CWS/mle cc:

R. Conte C. McCracken H. Silver