ML20092L183

From kanterella
Jump to navigation Jump to search
Application for Amend to License DPR-66,consisting of Change Request 103,requiring Performance of Battery Svc Test During Fourth Refueling Outage & at 18-month Intervals Thereafter
ML20092L183
Person / Time
Site: Beaver Valley
Issue date: 06/21/1984
From: Carey J
DUQUESNE LIGHT CO.
To:
Shared Package
ML20092L181 List:
References
NUDOCS 8406290272
Download: ML20092L183 (1)


Text

h.

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of Duquesne Light Company

)

Docket No. 50-334 (Beaver Valley Power Station, Unit No.1)

)

APPLICATION FOR AMENDMENT TO OPERATING LICENSE Pursuant to Section 50.90 of the regulations of the U. S. Nuclear Regulatory Commission (the " Commission"), Duquesne Light Company ("DLC"),

holder of Operating License No. DPR-66, hereby requests that the Technical Specifications set forth in Appendix A to that license be amended to require performance of a battery service. test during the fourth refueling outage and at 18-month intervals thereafter.

The proposed technical specification change is set forth in Attachment A to this Application.

A safety evaluation is set forth in Attachment B.

Based on the guidance provided by the Commission and examples of changes not likely to involve a significant hazards consideration, published in the Federal Register (48 FR 14864), we have determined that the proposed change falls within the following commissions examples:

(1) A purely administrative change to technical specifications.

Therefore, in accordance with 10 CFR 50.92, we have determined this proposed change is not'likely to involve a significant hazards consideration.

WHEREFORE, Applicant respectfully requests that Appendix A to Operating License No. DPR-66 be amended in the form attached hereto as Attachment A.

Duquesne Light Company By

/

M V. Carey

/

Vice President, Nuclear Subscribed and sworn to before me on this 8 F day of J u4/E A,/&ncack 2

V M[LVA CYANOVICH, hCTIJY PUBUC HOPEWEtt TOWNSHIP, BEAVER COUNTY MY COMISSfCN UPIRES NOV. 17.1935 keeter, Permsyhs:na A:swiation of Notadas 8406290272 840621 PDR ADOCK 05000334 i.

P PDR