ML20092J001
| ML20092J001 | |
| Person / Time | |
|---|---|
| Site: | Clinton (NPF-062) |
| Issue date: | 09/14/1995 |
| From: | Pickett D Office of Nuclear Reactor Regulation |
| To: | |
| Shared Package | |
| ML20092J007 | List: |
| References | |
| NPF-62-A-101 NUDOCS 9509210277 | |
| Download: ML20092J001 (4) | |
Text
-
~
pa ua
[
lt UNITED STATES g
,j NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20066-0001
\\...../
ILLIN0IS POWER COMPANY. ET AL.
DQfgET NO. 50-461 CLINTON POWER STATION. UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.101 License No. NPF-62 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Illinois Power Company * (IP), and Soyland Power Cooperative, Inc. (the licensees) dated June 9,1995, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission;,
C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common
~
defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifi-cations as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-62 is hereby amended to read as follows:
- Illinois Power Company is authorized to act as agent for Soyland Power Cooperative, Inc. and has exclusive responsibility and control over the physical construction, operation and maintenance of the facility.
l 9509210277 950914 PDR ADOCK 05000461 l
P PDR
. (2)
Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No.101
, are hereby incorporated into this license.
Illinois Power Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
3.
This license amendment is effective as of its date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION
\\/ k Douglas V. Pickett, Project Manager Project Directorate III-3 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance:
September 14, 1995 9
ATTACHMENT TO LICENSE AMENDMENT N0.101 FACILITY OPERATING LICENSE NO. NPF-62 DOCKET NO. 50-461 Replace the following page of the Appendix "A" Technical Specifications with the attached page.
The revised page is identified by amendment number and contain a vertical line indicating the area of change.
Remove Paaes Insert Paaes 4.0-1 4.0-1 i
l l
Design Features 4.0 f4.0 DESIGN FEATURES 4.1 Site Location The site for the Clinton Power Station is located in Harp Township, DeWitt County, approximately six miles east of the city of Clinton in east-central Illinois. The exclusion area boundary shall have a radius of 975 meters from the Standby Gas Treatment System vent.
4.2 Reactor Core 4.2.1 Fuel Assemblies The reactor shall contain 624 fuel assemblies.
Each assembly shall consist of a matrix of Zircaioy or ZIRLO clad fuel rods with an initial composition of natural or slightly enriched uranium dioxide (U0 ) as fuel material, and water rod (s).
Limited 2
substitutions of zirconium alloy or stainless steel filler rods for fuel rods, in accordance with approved applications of fuel rod configurations, may be used.
Fuel assemblies shall be limited to those fuel designs that have been analyzed with applicable NRC staff approved codes and methods and shown by tests or analyses to comply with all safety design bases. A limited number of lead test assemblies that have not completed representative testing may be placed-in nonlimiting core regions.
4.2.2 Control Rod'Assembilgi The reactor core shall contain 145 cruciform shaped control rod assemblies. The control material shall be boron carbide or t
hafnium metal, or both.
(continued) f 4
4 CLINTON 4.0-1 Amendment No.-95, 101 l
~
U
.