Research Reactor Center II h!h1 Research Park Columbia. Missouri 65211 UNIVERSITY OF MISSOURI-COLUMBIA
- %3(3hQ2d p
August 11,1995 050-coMG Ms. Gloria Bennington gg Spent Fuel Project Oflice U.S. NRC, MS TWFN 8 F-5 1 Whiteflint North 11545 Rockville Pike Rockville, MD 20852-2738
SUBJECT:
Shipment of Spent Fuel: Radioactive Material, Fissile, N.O.S., UN2918, Ifighway Route Controlled Quantity.
The enclosed envelope contains information regarding radioactive spent fuel shipments from the University of Missouri Research Reactor. This information has been classified as SAFEGUARDS INFORMATION as per 10CFR73.21(b)2. No person may have necess to Safeguards Information unless the person has an established "need to know" for this information and is authorized per 10CFR73.21(c). Regulations prevent the disclosure of this information over unsecured telephone communications except that the reporting of schedule changes are permitted to be made by phone in the form of time deviations from the original schedule. Please deliver the enclosed envelope which contains Safeguards Information to the addressee on the envelope. If this person is no longer employed at your facility or will be absent for an extended period, please call (314) 882-5205 for the correct disposition of this material.
Armed escorts have been arranged for St. Louis, Nashville, Knoxville, Asheville, and Greenville-Spartanburg, for these spent fuel shipments. Also, governors' designees of Missouri, Illinois, Kentucky, Tennessee, North and South Carolina have been mailed notifications.
The following information and the enclosed SAFEGUARDS INFORMATION are supplied to comply with 10CFR73.37(fXiXii)(iii).
Shipper:
University of Missouri Research Reactor Center Columbia, MO 65211 Phone: (314) 882-5205 (Roland A. Ilultsch)
Carrier:
Tri-State Motor Transit Co U.S. DOE Idaho Operations OfTice 785 DOE Place Idaho Falls,ID 83403 Phone: (208) 526-2415 (Keith Nelson)
Receiver:
Department of Energy Westinghouse Savannah River Company Savannah River Site 731-1G Receiving Aiken, SC 29802 Matthew J. Beckum j
Building 244-11 Phone: (803) 557-8773 g
E COLUM,BIA.
E y.UN an eaual coDarturutv institutum g
9509150245 950811 PDR ADOCK 05000186 F
w il b
Letter to Ms. Bennington August 11,1995 Page 2 i
(
49CFR172.202(aXIX2X3X4)
Proper shipping name, hazard RQ radioactive material, fissile, n.o.s., radioactive class, identification number, material UN2918,25,000 lbs.
gross weight 172.203(c)
RQ (Reportable Quantity) 1.5 kg of fission products; 5.0 kg U-235 49CFR172.203(d)(1)
(i) 173.435, radionuclides MFP(Mixed Fission Products) l (ii) Physical and chemical form Solid metallic, UAls and Al mixed with fission products trapped in this matrix. The UAI,--Al-fission product material is clad with aluminum as fuel plates of MTR-type (Materials Testing Reactor) fuel elements.
(iii) Activity (Curies) 185,000 49CFR173.403(1X3)
Greater than 30,000 Ci, so highway route controlled quantities.
(iv) Label category RADIOACTIVE YELLOW III because it is highway route controlled quantity.
(v) Transport index Based on measurement of radiation level at 3.3 ft. from cask cover. This it measured at the time of shipment, and in our past shipments, has been < 0.5 millirem /hr.
Hence TI =.5 per 49CFR173.403(bbX1). (The DOT has confirmed that this section, and not 49CFR173.403 (bbX2), is applicable.)
]
(vi) Fissile class III per 49CFR173.455(aX3). This rneans by 49CFR l
173.457(bX1) that transport must be with exclusive use l
of shipper.
(vii) Package identification number USN5957/B( )F (Model No. BMI-1)
Mode of transport Highway truck, exclusive use. No transfer points.
j Route enclosed as Safeguards Information.
l J
Sincerely yours, Roland A. Hultsch Reactor Physicist bjb