Amend 101 to License DPR-49,changing Testing Frequency of Scram Discharge Vol Vent & Drain Valves as Result of Completion of long-term Scram Discharge Vol Mods
ML20092D227
Person / Time
Site: Duane Arnold 
Issue date: 06/01/1984
From: Vassallo D
Office of Nuclear Reactor Regulation
To:
Corn Belt Power Cooperative, Central Iowa Power Cooperative, Iowa Electric Light & Power Co
Shared Package
ML20092D230 List:
References
DPR-49-A-101 NUDOCS 8406210522
Download: ML20092D227 (4)


Text

.

p Era o

UNITED STATES g,

NUCLEAR REGULATORY COMMISSION

[j)gsyg. i 2e WASMNGTON, D. C. 20555

~ %;ff s

IOWA ELECTRIC LIGHT AND POWER COMPANY CENTRAL IOWA POWER COOPERATIVE CORN BELT POWER COOPERATIVE DOCKET NO. 50-331 DUANE ARNOLD ENERGY CENTER AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.101 License No. DPR-49 1.

The Nuclear

  • Regulatory Comission '(the Comission) has found that:

A.

The application for amendment by Io'wa Electric Light & Power Company, et al, dated January 26, 1984, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifi-cations as indicated in the attachment to this license amendment-and paragraph 2.C.(2) of Facility Operating License No. DPR-49 is hereby amended to read as follows:

~

8406210522 840601 PDR ADOCK 05000331 P

PDR

l !

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.101, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the fechnical Specifications.

3 The' license amendment is effective as of the date of its issuance.

FOR THE NijCLEAR REGULATORY COMMISSION

" ^

Domenic B.,Vassallo, Chief Operating Reactors Branch #2 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance:

June 1, 1984

a ATTACHMENT TO LICENSE AMENDMENT NO. 101 FACILITY OPERATING LICENSE NO. DPR-49 DOCKET N0. 50-331 Revise the Appendix A Technical Specifications by removing the current page and inserting the revised page listed belcw.

The revised areas are identified by vertical lines.

LIST OF AFFECTED PAGES 3.3 - 2 s

6 N

v e

+

UMtL-1 LIMITING CONDITION FOR OPERATION SURVEILLANCE REOUIREMENT b.

The control rod directional.

b.

A second licensed operator control valves for inoperable shall verify the conformance to control rods shall be disarmed Specification 3.3.A.2d befora a electrically and the control rod may be bypassed in the Rod rods shall be in such position Sequence Control System.

that Soecification 3.3. A.1 is

met, c.

Control rods with inoperable c.

Once per week when the plant is accumulators or those whose in operation, check status of position cannot be positively pressure and level alarms for determined shall be considered each CR0 accumulator.

inoperable.

d.

Control rods with a failed d.

Once per cuarter verify that:

l

" Full-in" or " Full-out" position switch may be (1) the Scram Discharoe Volume bypassed in the Rod Sequence (SDV) vent and drain valves Control System and considered close within 30 seconds operable if the actual rod after receipt of a close position is known.

These rods sional, and must be moved in sacuence to their correct positions (full-(2) after removal of the close in on insertion or full-out on signal, that the SOV vent withdrawal).

and drain valves are ooen.

Once per' month verify that e.

Control rods with scram times the SDV vent and drain valve creater than those permitted position indicating lichts by Specif'ication 3.3.C.3 are located in the control room inocerable, but if they can be indicate that the valves are inserted with control rod

open, drive pressure they need not be disarmed electrically, e.

Once per cycle verify that:

(1) the SDV vent and drain valves close within 30 seconds after receipt of a f.

Inoperable control rods shall signal for the control rods be cositioned such that to scram, and Specification 3.3.A.1 is met.

(2) open when the scram sional is reset.

i Amendment No.101 em nrn cum raum