{{#Wiki_filter:! i INSERVICE INSPECTION 1995 OUTAJE
SUMMARY
REPORT t OFTHE MILLSTONE UNIT 3 NUCLEAR POWER STATION FOR NORTIIEAST NUCLEAR ENERGY COMPANY WATERFORD, CONNECTICUT COMMERCIAL SERVICE DATE APRIL 23,1986 REPORT DATE L AUGUST 1995 FOR INTERVAL 1 PERIOD 3 Prepared By: Od8* #1a4. O D. R. MacNeill ISI Coordinator Reviewed By: u T. W. Lyh l Technical Programs Supervisor Approved By: b D G r U3 cc nical Support Manager r r 9509120050 950907 gDR.. - - PDR ADOCK 05000423
Abstract of Examinations This report contains a summary of the examination and test results for the inservice inspection (ISI) conducted at the Northeast Nuclear Energy Company Millstone Unit 3 Nuclear Power Station during the fifth refueling outage, which is the first outage of the third period of the first interval'. Included in this report are the required ASME Section XI forms for the items examined (NIS-1) and repairs and replacements (NIS-2) that have been completed since the last Inservice Inspection Summary Report was submitted in November 1993. Reported herein are the examinations and tests required by the ASME Section XI Code and the NRC through augmented requirements. All examinations and tests were completed as delineated in the Millstone Unit 3 Inservice Inspection Program Plan. All examinations and tests completed meet the acceptance criteria stated in Millstone Unit 3 Inservice Inspection Program Plan. All required examination and test records and associated documentation generated during the performance of this inservice inspection are maintained at the plant for the service life of the plant. l ' Under separate correspondence NNECo has requested approval for the use of Code Case N535. After receiving approval, NNECo will extend the first interval for a period of 12 months as allowed by Section XI and clarified by the subject code case. The interval will be extended an additional 6 months, as allowed by the Code due to the extended shutdown from July 1991 to February 1992. ii 1
1 Table of Contents Section Titic i Abstract ofExaminations ii . Table of Contents iii List ofTables iv j Abbreviations v Form NIS-1, Owner's Data Report vi l Form NIS-1, Owner's Data Report for Inservice Inspection vii Supplemental Sheet to form NIS-1 (Table 1-1) viii Form NIS-1 (back) ix i 1.0 Introduction 1 2.0 First Interval Summary 2 i First Interval-Category Summary (Table 2-1) 3 j j First Interval-Augmented Summary (Table 2-2) 5 j 3.0 Summary of Examinations 6 I I 4.0 Procedures 9 5.0 Personnel and Equipment Summary 10 6.0 Abstract of Corrective Measures Recommended and Taken 11 l 7.0 Form NIS-2, Owner's Report for Repairs and Replacements 12 i i 4 f 8.0 Drawing / Location (Zone) Isometrics 13 ) iii a
i List of Tables i i 4 Table 1-1 ~ Supplemental Sheet to Form NIS-1 viii Table 2-1 First Interval-Category Summary 3 Table 2-2 First Interval-Augmented Summary 5 f i i h i n t l l i l 1 l i iv i i
P b Abbreviations The following abbreviations are used in the summary report: Abbreviations Definition UT Ultrasonic Test PT Penetrant Test MT Magnetic Particle Test 'f RT Radiographic Test I ET Eddy Current Test VT-1,2,3,4 Visual Test ] NUSCO Northeast Utilities Service Co. I NNECO Northeast Nuclear Energy Co. S/G Steam Generator RPV Reactor Pressure Vessel B.E.A. Break Exclusion Area LPSI Low Pressure Safety Injection System RCS Reactor Coolant System RHS Residual Heat Removal System FWS Feedwater System MS Main Steam System SIL Low Pressure Safety Injection System FWA Auxiliary Feedwater System SWP Service Water Systen, CHS Chemical Volume Control System SIH Intermediate Safety Injection System HPSI High Pressure Safety Injection System i V
- 1. Form NIS-1 Owner's Data Report I
f Contained in this section is the owner's data report for inservice inspection, form NIS-1, as l required by ASME Section XI. Table 1-1 is provided as a supplementallist to the NIS-1 form. I i i ? P i i t i f l I l \\i i
t 1 1 FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules 2
- 1. Owner Northeast Nuclear Eneruv Company (Name and Address of Owner)
J
- 2. Plant Millstone P. O. Box 345. Waterford. CT 06385 (Name and Address of Owner)
- 3. Plant Unit 3
- 4. Owner Certificate of Authorization (if required)
None
- 5. Commercial Service Date 4/23/86
- 6. National Board Number for Unit N/A
- 7. ComponentsInspected
.j Component of Manufacturer Manufacturer State or National Appurtenance or Installer or Installer Province No. Board No. Serial No. Sec supplemental sheet 1 1 I l i i I i Note: Supplemental sheets in form oflists, sketches, or drawings may be used provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. This form (E00029) may be obtained from the Order Dept., ASME 345 E. 47th St., New York. N.Y.10017 Vii
1 \\ i 4 Table 1 1 Supplemental Sheet to Form NIS-1 NNECO - Millstone Unit 3 - Waterford, CT Commercial Service Date: 4/23/86 4 l Component or Manufacturer or Manuf. or Installer State or National Exam Cat. Appurtenance Installer Serial No. Province No. Board No. [ Reactor Vessel Combustion Eng. 7272 N/A N/A Il-A Reactor Vessel Combustion Eng. 7272 N/A N/A B-D Reactor Vessel Combustion Eng. 7272 N/A N/A Il-N-1 Reactor Vessel Combustion Eng. 7272 N/A N/A B-N-2 Reactor Vessel Combustion Eng. 7272 N/A N/A B-N-3 RPV Studs Combustion Eng. 7272 N/A N/A B-G-1 i Stcam Generator I A Westinghouse NEGT 1776 N/A W13584 Il-B, B-D ' i Ste:m Generator 1B Westinghouse NEGT 1775 N/A Wl3583 B-D l Steam Generator IC Westinghouse NEGT 1778 N/A W15216 B-B,B-D Ste:m Generator 1D Westinghouse NEGT 1774 N/A W15216 B-B,B-D S/G ID Manway Studs Westinghouse NEGT 1777 N/A W15216 B-G-2 RCS Class I llotting Stone & Webster See Summary Report N/A N/A B-G-2 j SIL Class 1 Bolting Stone & Webster See Summary Report N/A N/A B-G-2 j ClIS Class 1 Piping Stone & Webster See Summary Report N/A N/A Il-J SIL Class 1 Piping Stone & Webster See Summary Report N/A N/A B-J l RCS Class 1 Piping Stone & Webster See Summary Report N/A N/A B-J } IIIS Class 1 Piping Stone & Webster See Summary Report N/A N/A B4 1 RCS Int. Attachment Stone & Webster See Sununary Report N/A N/A B-K-1 Steam Generator I A Westinghouse NEGT 1776 N/A W13584 C-A i RIIR llX Noz. Welds Joseph Outs 2168-5A N/A 780 C-B l QSS Int. Attachment Stone & Webster See Summary Report N/A N/A C-C CllS Int. Attachment Stone & Webster See Summary Report N/A N/A C-C j RilS Int. Attachment Stone & Webster See Summary Report N/A N/A C-C 4 3 MSS-V7 Sultzer Bros. 5437 N/A 3 C-D SIL Class 2 Piping Stone & Webster See Summary Report N/A N/A C-F-1 j R11S Class 2 Piping Stone & Webster See Summary Report N/A N/A C-F-1 i RSS Class 2 Piping Stone & Webster See Summary Report N/A N/A C-F-1 1 QSS Class 2 Piping Stone & Webster See Summary Report N/A N/A C-F-1 j MS Class 2 Piping Stone & Webster See Sumnuuy Report N/A N/A C-F-2 { FWS Class 2 Piping Stone & Webster See Summary Report N/A N/A C-G l CCPInt. Attachments Stone & Webster See Summary Report N/A N/A D-B l Class i Supports Stone & Webster See Summary Report N/A N/A F-A Class 1 Supports Stone & Webster See Summary Report N/A N/A F-B i Class 1 Supports Stone & Webster See Summary Report N/A N/A F-C 4 ) Class 2 Supports Stone & Webster See Summary Report N/A N/A F-A Class 2 Supports Stone & Webster See Summary Report N/A N/A F-B i Class 2 Supports Stone & Webster See Sununary Report N/A N/A F-C Class 3 Supports Stone & Webster See Summary Report N/A N/A F-A C1:ss 3 Supports Stone & Webster See Summary Report N/A N/A F-B i Class 3 Supports Stone & Webster See Summary Report N/A N/A F-C i 4 Ykkk
i i t i j FORM NIS-1 (back) i i 8. Examination Dates: 4-12-95 to 6-12-95 2 i
- 9. -
Inspection Interval from 1986 to 1996 { ' 10. Abstract ofExamination. I l Include a list of examinations and a statement concerning status work required Abstract of. l Examinations for current interval. First Interval Summary is identified in Section 2.0 of this report. i "L
- 11. -
Abstract of Conditions Noted. 4 i All indications found during ISI that exceeded the acceptance criteria of ASME XI were removed, reduced to an acceptable size, or accepted by evaluation. See Section 3.0 for detailed q j list of conditions noted. i 4 12. Abstract of Corrective Measures Recommended and Taken. l i-All indications were either removed or reduced to an acceptable size, and removal was verified by reexamination. See Section 6.0 for detailed list of corrective measures recommended and taken. I r We certify that the statements made in this report are correct and the examinations and 1 corrective measures taken conform to the rules of the ASME Code, Section XI. Date 2 beh 19M Signed W II M by A.1 d e d e nni Certificate of Authorization No. (if applicable) N/A Expiration Date N/A l CERTIFICATE OF INSERVICE INSPECTION i I, the undersigned, holding a valid commission issue sure Vessel Inspectors and/or the State of Province of /q by the National Board of and employed by MrLT (A of crir '2/ 4 /8 have inspected the componen'ts des'cribed in this Owner's Data Report during the ,v o r erieff p/-/49r to 4#-f5, and state that, to the best of my knowledge and belief, described in this j 2 Owner's Data Report in accordance with the requirements of the ASME Code, Section XI. t By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or l i: implied, concerning the examinations and corrective measures described in this Owner's Data Report. l l Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury i . or property damage ~or a loss of any kind arising from or connected with this inspection. bl9fi Date Commissions Af 999/ Or#TS ' ' or's Si tdre T National Board, State, Pros;4cc and No. I i iX m i-m
F 1.0 Introduction i This inservice inspection summary report documents the inservice inspections conducted at l Millstone Unit 3 during the fifth refueling outage from April 12,1995 through June 12,1995. l These examinations and tests were performed in accordance with the Millstone Unit 3 Inservice Inspection Program Plan. J Welds, components, and their supports were examined in accordance with the requirements of the Millstone Unit 3 Technical Specification, Section 4.0.5 and the requirements of ASME 4 Boiler and Pressure Vessel Code, Section XI,1983 Edition, Summer 1983 Addenda except i where noted in the Millstone Unit 3 Inservice Inspection Program Plan. I a Millstone Unit 3 started commercial operation on April 23,1986. Therefore this fifm refueling } outage is the first outage in the third period. l 4 Also included in this summary report are augmented inservice inspections performed to meet additional NRC requirements. l Examination and test procedures were approved prior to the outage. Also, certification ] documents relative to personnel, equipment, and materials were reviewed and determined to be j satisfactory. I i Manual nondestructive and visual examinations and tests were performed by Northeast Nuclear i Energy Company, Northeast Utilities Service Company, ABB/Amdata, Inc., Rust Utilities, and j 4 l MQS, Inc. examination personnel. Automated and Manual Ultrasonic Examinations were j performed by personnel from Southwest Research Institute, Inc. l The Inservice Inspection Program was reviewed by the Hartford Steam Boiler Inspection and j insurance Company. They provided NNECO with the Authorized Nuclear Inservice Inspector i for the 1995 refueling outage. All required examination and test records and associated documentation generated during the i performance of this inservice inspection are maintained at the plant for the service life of the plant. y i l t I i t-t l y-y- w---, 2 r w r--
.- ~._. l i 2.0 First laterval Summary ] 2.1 Section XI i F A summary for the first interval is provided in Table 2-1 for those examination categories where a percentage requirement is imposed by Section XI. Examination Categories B-E, B-G-1, B-L-2, j B-M-2, B-N-1, B-N-2, B-0, B-P, C-H, are not included since the percentage requirement does not apply to them. 2.2 Augmented { t t Table 2-2 addresses the interval status for augmented examinations performed to meet NRC l requirements. Included in the listing are the augmented examinations to protect against postulated piping failures within the break exclusion area (B.E.A.) and the reactor coolant pump l l ' flywheel examinations required by Regulatory Guide 1.14 (RG 1.14). i ~ i ? I l i i 1 I e i i J i e l h L i t i i f + r P f i 4 i h
Table 2-1 First Interval-Category Summary Millstone Unit 3 RF05 Interval I Catenoly Percentages NISI Total Interval 1 Pmod i Pmod 1 Pmod I Pmod 2 Pmod 2 Pmod 2 Penod 3 Pened 3 Pmod 3 Total Percent Footnote Categnry Active Scheduled Schedsled Complete Percent Scheduled Cmudeve Percent Scheshle Complete Percent Complete Caudete B-A 2 2 1 1 50 0 0 50 1 1 100 2 100 1 B-B B 8 2.5 2.5 31 2 2 60 4 3 100 8 88 B-D 44 44 6 6 27 5 5 50 11 10 100 44 95 2 B-F 22 22 4 4 18 7 7 30 11 10 100 21 95 BC,-2 62 62 19 19 31 14 14 55 29 29 100 62 100 B-H 9 9 I I 11 8 8 100 0 0 100 9 100 3 BJ 1193 424 146 146 33 172 172 66 105 105 100 424 100 4 B-K-1 10 6 2 2 33 2 2 66 2 2 100 7 100 l B-N-1 1 1 1 1 100 1 1 100 1 1 100 3 100 B-P 5 5 5 5 100 5 5 100 5 5 100 15 100 C-A 24 6 2 2 33 1 1 50 3 3 100 6 100 I C-B 28 9 3 3 33 2 2 55 4 2 100 '7 78 I CC 43 26 10 8 31 9 9 65 9 7 100 26 92 5 i C-D 6 2 0 0 0 0 0 0 2 1 50 1 50 6 ~ C-F-1 2466 231 48 48 26 80 80 69 103 82 100 210 91 7 C-F-2 543 76 29 29 33 16 16 66 18 18 100 62 100 8 C-O 2 1 0 0 0 0 0 0 1 0 100 0 0 9 C-H 12 12 12 12 100 12 12 100 12 9 100 33 75 i 6 3 ,. ~., _ _.. _ _ ___ _,. _ _ _ _..___, _... _. _ _. _. _ _. _,
Total Interval 1 Penod1 Pmod 1 Penod1 Pmod 2 Pmod 2 Pmod 2 Pmod 3 Pmod 3 Pened 3 Total Pertw Footrue Categrev Actm Scheduled Scheduled Complete Percent Scheduled Cormlete Percent Schedule Cormlete Percent Complete Cormlete C1,1 673 169 112 56 33 58 58 66 95 95 100 265 100 9 Cl 2 582 88 116 30 33 20 20 57 60 59 100 197 100 9 Cl 3 747 75 222 222 33 89 89 66 69 69 100 380 100 9 D-A 24 2 1 1 100 1 1 100 2 1 100 3 100 10 D-B 102 59 18 18 100 25 25 100 27 22 100 65 100 10,11 D.C 2 2 1 1 100 2 2 100 1 0 100 3 100 10 TOTALS 6610 1341 763.5 617.5 531 531 576 521 1841 Footnotes
- 1. Partial Deferals.
- 7. Only 185 exams required durmg Pmods I and 2; 203 required Pmod 3 Percent based on this t<tal.
- 2. 22 Nozzles total; category requires mmmnern 25% at end of first Inter /al
- 8. Only 41 cmm.-m,6 required. Percentages shown are based on this total.
- 3. Rehef Request Oranted.
- 9. One C.G category component scheduled with Sill pipe exams utadt are added m 1993.
- 4. Category requires a total of 299 Emm.mw Percentages shovm are based on this total
- 10. Numbers reflect 259=,15% and 10% for Class 1,2,3 respectively (Per N491)
- 5. Per code case N491 only 7 Exammations required Percentages shown are based on this total.
I1. Category mcludes pressure tests and integral ="=chmaata (both % shown)
- 6. Only one required until augmented exams from NRC on Sill Imes in 1993
- 12. Only 15 miegral attachmeros required for D-B category.
4
t Table 2-2 First Interval-Augmented Summary t Essen team. Teea1 be. I Pertem Pmod 1 Pmod 1 PenedI 8 Pmod 2 Pmod 2 Pmod 2 8 Punod 3 Pened 3 - Penad 3 8 Total Percent Categev No. Active sched TeeniPop ! Mied Conglete Percent ! Scheduled Caniplete Percent ! Schedule Cosipiece Percent ! Caiplete C+ AUG B.E.A 456 435 100.0 % 47 47 11 % 197 197 57 % 191 191 100 % 435 100 % AUG RG 1.14 4 4 100.0 % 4 4 100 % 4 4 100 % 4 3 300 % 3 75 % ~ AUG - IEB7913 98 98 100.0 % 96 96 98*4 2 2 100 % 0 0 100 % 98 100.0 % AUG IEB8811 3 3 100.0 % 3 3 100 % 4 4 100 % 0 0 100 % 3 100.0 % s i i i 1 3 s a 'S .[ .,.,_____m _..__..,-._-,._,._.--,_.-.-__..,-..,_.c- . _., _.,. _. - _,. _ _. _. ~ -. _....
i 3.0 Abstract of Conditions Noted 3.1 Summary of Examinations This section provides a detailed list of the examinations and tests conducted since the last summary report was issued. It should be noted that all examinations and tests listed in this report were conducted during the 1995 refueling outage. This list is by examination category and includes the examination method and results along with the identification of the weld or component. Included are the conditions noted on the examination data sheet and their resolution. The results of the examinations are listed as satisfactory, acceptable, or repaired. Satisfactory defines an examination which found no relevant indications. Acceptable defines an examination which found relevant indications, but were dispositioned acceptable per the Acceptance Criteria. Repaired defines an examination which revealed an unacceptable indication which was corrected. Acceptance Criteria was based on ASME Section XI,1983 Edition, Summer 1983 Addenda, except for certain Class 2 welds and components which were based on the 1983 Edition, Winter 1985 Addenda, as noted in the Inservice Inspection Program Plan. Following is a summary of the examinations completed and any limitations noted during the exam: Examination items Catenorv Examined Limitaligns AUG (RG 1.14) 3 None AUG (B.E A) 191 None B-A 19 See Note 1 B-B 3 None B-D 28 See Note 2 B-E 1 None B-F 10 None B-G-1 95 None B-G-2 29 None B-J 105 None B-K-1 2 None B-N-1 1 None B-N-2 7 None B-N-3 2 None B-P 5 None C-A 3 None C-B 2 None C-C 7 None C-D 1 None C-F-1 82 None C-F-2 18 None C-II 9 None 6 i
Class 1 Supports 95 None Class 2 Supports 59 None Class 3 Supports 69 None D-A 1 None D-B .22 None Notes: (1) - Limitations found on category B-A are documented and approved under Relief Request IR-1. (2) Limited exam due to intergral extention or nozzle geometry. NNECo to submit reliefrequest. 3.2 Successive Examinations Three supports in examination category F-B and ten in F-C were examined as successive . examinations from period 2. f l 3.3 Reactor Vessel Ten-year ISI j 4 Southwest Research Institute (SwRI) personnel performed nondestructive examination (NDE) of selected reactor pressure vessel (RPV) welds, and reactor coolant system piping welds at NNECO Millstone Power Station, Unit 3 (MNP3). These were the first inservice examinations (ISI) performed on the reactor vessel at MNP3 during the third period of the first 10-year interval of commercial operation.
- 1. Examination Areas
~ The following RPV, and associated piping weld examination areas were examined by SwRI personnel utilizing automated ultrasonic (AUT) and remote visual (VT) techniques: Reactor Pressure Vessel Lower Head Circumferential Welds Lower Head Meridional Welds RPV Circumferentiel Welds RPV Longitudinal Welds Inlet and Outlet Nozzle-to-Shell Welds Inlet and Outlet Nozzle Inner Radius Inlet and Outlet Nozzle-to-Safe End Welds VesselInterior
- 2. Examination Activities A. Remote VT Examinations l
7
s A remote VT examination was performed on the RPV inteilor using the par j Device mounted camera. The VT-3 examination was conducted to determine the mechanical and structural condition of the vessel's interior and attachments. The visual examinations were performed in accordance with NNECO procedure NU-VE4, Rev. O. I j B. RPV AUT Examinations { AUT examinations were performed on the reactor vessel welds from the inside surface (ID) utilizing the par Device with Fast par and Enhanced Data Acquisition i System (EDAS*) equipment. The examination areas included nozzle-to-shell welds from the bore and vessel wall, nozzle inner radius, nozzle-to-piping welds, and vessel l l circumferential and longitudinal welds. i RPV Inlet and Outlet Nozzle-to-Safe End Welds i In accordance with NNECO's request for relief number IR-9, Rev.1, a full-valume UT examination of the weld and base metal was performed in lieu of a surface i 1 examination. SLIC 40 refracted longitudinal; wave search units were used for the nozzle i i bore for detection of reflectors in the weld arid 1/2 inch of base material on each side of the outside surface (OD) weld fusion lines. The SLIC 40 search units were manipulated i -- and scanned in four directions [towards (TWD), away (AWY), counterclockwise (CCW), l and clockwise (CW)] to obtain full-volume coverage. Prior to onsite examinations, this technique had been demonstrated to NNECO and USNRC in accordance with the relief i request requirements. i l 3, Examination Results The remote VT examination revealed three foreign objects in the lower head. A l site Unresolved Indication Report (UIR) was used to report this condition. A copy of UIR Number MP3-95-061 is contained in the VT examination data in the Final Report. l t The AUT examination of the RPV detected indications on RPV circumferential { welds 101-121,101-171,102-151, and 103-121; RPV longitudinal welds 101-124B,101-l 124C, and 101-142B; RPV nozzle-to-shell welds 105-121C, and 105-121D; and RPV nozzle inner radius weld 107-121-D-IR. These indications were sized with AUT SLIC 20 and/or AUT SLIC 30,35, and 40 search units. Based on.ne sizing data, the Level III analyst was able to determine that the indications were Code allowable in accordance with l IWB-3500 of ASME Section XI. i i i h I i t i 8 l t I i
k f MILLSTONE UNIT 3 RFOS NDE RESULTS
SUMMARY
NIS 1 CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS AUG ] CilS 1 CliS-503-FW-1 PT Satisfactory None CilS-503-FW 2 PT Satisfactory None f CilS-503-FW-21 PT Satisfactory None 1 l FWS l FWS-I l-FW-6-JM UT Satisfactory None i MT Satisfactory None 1 FWS-13-FW-7 JM UT Satisfactory None MT Satisfactory Nonc FWS-21-FW-1 UT Satisfactory None MT Satisfactory None FWS-22-FW-1 UT Satisfactory None 4 MT Satisfactory None FWS-24-FW-1 UT Satisfactory None i MT Satisfactory None MS j DTM-25-1-SW-G MT Satisfactory None DTM-25-1-SW-N MT Satisfactory None DTM-25-FW-10 MT Satisfactory None DTM-25-FW-l l MT Satisfactory None DTM-25-FW-12 MT Satisfactory None DTM-25-FW-2 MT Satisfactory None i DTM-25-FW-39 MT Satisfactory None DTM-25-FW-6 MT Satisfactory None DTM-25-FW-7 MT Satisfactory None DTM-25-FW 8 MT Satisfactory None DTM-25-FW-9 MT Satisfactory None DTM-28-FW-1 IJT Satisfactory None MT Satisfactory None DTM-31-1-SW-G MT Satisfactory None Report: rptNDEResultsSm p,g, g og 4g Sorted: Cat / System /ReferencelD i
... _.. ~ _... _ _ _. _ _ _ l l l i CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS DTM 31 FW-1 UT Satisfactory None MT Satisfactory None DTM-31-FW-1-EM UT Satisfactory None MT Satisfactory None i DTM-31-FW-17 MT Satisfactory None DTM-31-FW-18 MT Satisfactory None DTM-31-FW-19 MT Satisfactory None t i ). DTM-31-FW-20 MT Satisfactory None i DTM-31-FW-21 MT Satisfactory None I DTM-31 FW-22 MT Satisfactory None l DTM-11 FW-41 MT Satisfactory None DTM-31-FW-42 MT Satisfactory None [ t i { DTM-341 SW-C MT Satisfactory None t l DTM-34 1-SW-D MT Satisfactory None I i DTM-34 1-SW-G MT Satisfactory None DTM-34-FW-1 UT Satisfactory None i MT Satisfactory None l DTM-34-FW-l-EM UT Satisfactory None l MT Satisfactory None l DTM-34-FW-23 MT Satisfactory None DTM-34-FW-24 MT Satisfactory None I DTM-34-FW-25 MT Satisfactory None 2 DTM-34-FW-26 MT Satisfactory None i DTM-34-FW-27 MT Satisfactory None DTM-34-FW 39 MT Satisfactory None ] DTM-34-FW-40 MT Satisfactory None i i DTM-34-FW-41 MT Satisfactory None j DTM 34-FW-42 MT Satisfactory None i DTM-34-FW-43 MT Satisfactory None i i MSS-25-1-SW-B MT Satisfactory None MSS-25-1-SW-D MT Satisfactory None MSS-25-1-SW-E MT Satisfactory None a Report; rptNDEResultsSummary PQ 2 M Sorted: Cat / System /ReferencelD j J
CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS MSS-25-1-SW-F MT Satisfactory None MSS-25-1 SW-G MT Satisfactory None MSS-25-FW-1 MT Satisfactory None MSS-25-FW-2 MT Satisfactory None MSS-25-FW 1 MT Satisfactory None MSS-26-1 SW-D MT Satisfactory None MSS-26-1-SW-E MT Satisfactory None MSS-26-FW-2 MT Satisfactory None MSS-26-FW-8 MT Satisfactory None MSS-27-1-SW-B MT Satisfactory None MSS-27-1-SW-C MT Satisfactory None MSS-27-1-SW-D MT Satisfactory None MSS-27-1 SW-E MT Satisfactory None MSS-27-FW-1 MT Satisfactory None MSS-27-FW-2 MT Satisfactory None MSS-28-1 SW-B MT Satisfactory None MSS-28-1-SW-C MT Satisfactory None MSS-28-1 SW-D MT Satisfactory None M SS-28-1-SW-E MT Satisfactory None M SS-28-1-SW-F MT Acceptable 2 Indications Found 1/16" Apart. A Linear Indication Curved At Ends 3/8" Total Length. I MSS-28-1-SW-G MT Satisfactory None MSS-28-FW-1 MT Satisfactory None MSS-28-FW-2 MT Satisfactory None M SS-29-FW-1 UT Acceptable 3/4" inclusion in pipe. MT Satisfactory None MSS-29-FW-1-BM UT Satisfactory None MT Satisfactory None MSS-29-FW-1-EM UT Acceptable Geometry MT Satisfactory None MSS-29-FW l-FM UT Satisfactory None MT Satisfactory None Report: rptNDEResultsSummary Pap 3o N Sorted: Cat / System /ReferencelD
_. _. _. ~.. i CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS r MSS-29-FW-1-GM UT Satisfactory None l MT Satisfactory None MSS-29-FW 2 UT Satisfactory None MT Satisfactory None j MSS-29-FW-2^ UT Satisfactory None 5 MT Satisfactory None i MSS-29-FW-2M UT Satisfactory None i MT Acceptable Indications Appear To Be Laps In The Pipe MSS-29-FW-3M UT Satisfactory None MT Satisfactory None j i i MSS-30-FW-1-CM UT Satisfactory None MT Acceptable Re-Examined Indication Areas After Light Flapping MSS-30-FW-2 UT Satisfactory None MT Satisfactory None f MSS-30-FW-2-2M UT Satisfactory None MT Acceptable None MSS-30-FW-6 UT Satisfactory None l MT Acceptable Re-Examined Indication Areas Afler Light Flapping. MSS-31 FW-1 UT Acceptable Spot indication MT Satisfactory None l MSS-31 FW l-2M UT Satisfactory None MT Satisfactory None MSS-31-FW-1-BM UT Satisfactory None MT Satisfactory None MSS-31-FW t-CM UT Satisfactory None MT Satisfactory None MSS-31 FW 2 UT Satisfactory None MT Satisfactory None MSS-31 FW-6 UT Satisfactory None MT Satisfactory None MSS-32-FW-1 UT Satisfactory None MT Satisfactory None MSS-32-FW-1 2M UT Satisfactory None MT Satisfactory None 1 i Report: rptNDEResultoSunmwy p,g,4 og49 Sorted: Cat / System /ReferencelD i - _ ~. -
CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS MSS-32-FW 1-3M UT Satisfactory None MT Satisfactory None MSS-32-FW 1-BM UT Satisfactory None MT Satisfactory None MSS-32-FW-1-EM UT Satisfactory None ] MT Satisfactory None i MSS-32-FW 1-FM UT Satisfactory None MT Satisfactory None 1 MSS-32-FW-1-GM UT Satisfactory None MT Satisfactory None i j MSS-32-FW-il UT Satisfactory None l MT Acceptable Indication Removed By Surface j Prep 4 MSS-32-FW 2 UT Satisfactory None 2 MT Satisfactory None MSS-33-1 SW-P MT Satisfactory None i MSS-33-FW-1 UT Satisfactory None MT Satisfactory None MSS-33-FW-1-BM UT Satisfactory None l MT Acceptable None 4 i MSS-33-FW-1-FM MT Satisfactory None l MSS-33-FW-1-GM UT Satisfactory None j MT Satisfactory None MSS-33-FW-1-ilM UT Satisfactory None MT Satisfactory None MSS-33-FW 1-JM MT Satisfactory None MSS-33-FW-1-LM MT Satisfactory None MSS-33-FW-l-LS-1 UT Satisfactory None l MT Satisfactory None L f MSS-33-FW-1-LS-5 UT Satisfactory None MT Satisfactory None l l MSS-33-FW-1-LS-6 UT Satisfactory None j MT Satisfactory None l i MSS-33-FW 1-LS-7 UT Sa:isfactory None j MT Satisfactory None ) MSS-33-FW-1-MM MT Satisfactory None j Report: rptNDEResultsSummy Page 5 of 41 Sorted: Cat / System /ReferencelD i
CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS MSS-33-FW-l-RM MT Satisfactory None MSS-33-FW-1-TM MT Satisfactory None MSS-33-FW-1-VM MT Satisfactory None MSS-33 FW-1-XM MT Satisfactory None MSS-33-FW-2 UT Satisfactory None MT Satisfactory None MSS-33-FW-3 UT Acceptable Root geometry indication 1/2" long. MT Satisfactory None MSS-33-FW-4 UT Satisfactory None MT Satisfactory None MSS-34-1-SW-G MT Satisfactory None MSS-34-FW-1 UT Acceptable Root geometry indication. MT Satisfactory None MSS-34-FW-1-BM UT Satisfactory None MT Satisfactory None MSS-34-FW-1-FM MT Satisfactory None MSS-34-FW-1 JM MT Satisfactory None MSS-34-FW-1-LS-l M UT Satisfactory None MT Satisfactory None MSS-34-FW-1-LS-SM UT Satisfactory None MT Satisfactory None MSS-34-FW-1-LS-6M UT Satisfactory None MT Satisfactory None MSS-34-FW-1-LS-7M UT Satisfactory None MT Satisfactory None MSS-34-FW 1-MM MT Satisfactory None MSS-34-FW-1-RM MT Satisfactory None MSS-34-FW-1-TM MT Satisfactory None MSS-34-FW-1-VM MT Satisfactory None MSS-34 FW-2 UT Acceptable Geometry MT Satisfactory None MSS-34-FW-2-GM UT Satisfactory None i l MT Satisfactory None Report: rptNDEResultsSummery Page 6 of 41 Sorted: Cet/ System /ReferencelD l l
CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS 1 j MSS-34-FW-3 UT Acceptable Geometry i MT Satisfactory None 4 MSS-34-FW-4 UT Acceptable Geometry l j MT Satisfactory None MSS-35-1 SW-P MT Satisfactory None u i MSS-35-FW-1 UT Acceptable Geometry I MT Satisfactory None MSS-35-FW-1-BM UT Satisfactory -None MT Satisfactory None MSS-35-FW-1-FM MT Satisfactory None i 1 MSS-35-FW 1-GM UT Satisfactory None MT Satisfactory None ] 1 MSS-35-FW 1-ilM UT Satisfactory None MT Satisfactory None MSS-35-FW-1-JM MT Satisfactory None MSS-35-FW 1-LS-SM UT Satisfactory None l MT Satisfactory None MSS-35-FW. I-LS-6M UT Satisfactory None MT Satisfactory None MSS-35-FW-1-LS-7M UT Acceptable 0.1 wide x 0.5 long slag inclusion j MT Satisfactory None MSS-35-FW-1-MM MT Satisfactory None j MSS-35-FW-1-RM MT Satisfactory None l MSS-35-FW-1-TM MT Satisfactory None + j MSS-35-FW-1-VM MT Satisfactory None s I MSS-35-FW 1 XM MT Satisfactory None i MSS-35-FW-1 ZM MT Satisfactory None MSS-35-FW-2 UT Satisfactory None MT Satiafactory None i MSS-35-FW 2-LS-lM UT Satisfactory None MT Satisfactory None MSS-35-FW-3 UT Acceptable Geometry i. MT Satisfactory None MSS-35-FW-4 UT Acceptable Geometry MT Satisfactory None Report: rptNDEResulteSummary p,,, 7,9 49 Sorted: Cat / System /ReferencelD
l CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS MSS-35-FW-V7-lM MT Satisfactory None MSS-35-FW-V7-2M MT Satisfactory None i MSS-35-FW-V7 3M MT Satisfactory None . MSS-36-1-SW-P MT Satisfactory None j MSS-36-FW-1 UT Acceptable Geometry MT Satisfactory None MSS-36 FW-1 BM UT Satisfactory None MT Satisfactory None MSS-36-FW 1-FM MT Satisfactory None MSS-36-FW-1-GM UT Satisfactory None l MT Acceptable 7/16" axial linear. 1 MSS-36-FW-1-ilM UT Satisfactory None MT Satisfactory None t MSS-36-FW 1-JM MT Satisfactory None MSS-36-FW 1-LS-lM UT Satisfactory None MT Satisfactory None j i M3S-36-FW-1-LS-SM UT Satisfactory None MT ' Acceptable 100% Of The Long Seam Was l Examined For Cire. Weld. ) MSS-36-FW 1 LS-6M UT Satisfactory None MT Satisfactory None [ { MSS-36-FW-l LS-7M UT Satisfactory None j MT Satisfactory None MSS-36-FW-1-M M MT Satisfactory None i MSS-36-FW-l-RM MT Acceptable 3/8" Long Indication Appears To ) De Porosity Caused By An Arc Strike 4 I MSS-36-FW 1-TM MT Satisfactory None MSS-36-FW-1-VM MT Satisfactory None MSS-36-FW-t-XM MT Satisfactory None i MSS-36-FW-1-ZM^ MT Satisfactory None l MSS-36-FW-2 UT Satisfactory None l MT Satisfactory None MSS-36-FW-3 UT Acceptable Geometry MT Satisfactory None Report: rptNDEResulteSummary p,9,,,,49 Sorted: Cet/ System /ReferencelO n
CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS MSS-36-FW-4 UT Acceptable Geometry MT Satisfactory None MSS-36-FW-V10-lM MT Satisfactory None MSS-36-FW V10-2M MT Satisfactory None MSS-36-FW-V10-3M MT Satisfactory None MSS-502-FW-6 UT Satisfactory None MT Satisfactory None MSS-503-FW-4 UT Satisfactory None MT Satisfactory None MSS-503-FW-8 UT Satisfactory None MT Satisfactory None RCS 03-008-005 UT Satisfactory None ET Satisfactory 03-009-005 UT Satisfactory None ET Satisfactory 03-010-005 UT Satisfactory Done by Westinghouse ET Satisfactory Done by Westinghouse 03-011-005 UT Satisfactory None ET Satisfactory Sill Sill-502-FW-1 PT Satisfactory None Sill-503-FW-1 PT Satisfactory None Sill-504-FW-1 PT Satisfactory None SIL SIL-25-FW-9 UT Satisfactory None PT Satisfactory None SIL-9-FW-2 UT Satisfactory None PT Satisfactory None B-A RPV 101-121 UT Acceptable Code Allowable Indication. 101-122A UT Satisfactory Plate Segregates in the Base Material. Limited Exam Due To Proxmity To Inlet Nozzle. See Relief Request IR-l. Report: rptNDEResdtsSummary p,g,9 og 43 Sorted: Cat / System /ReferencelD 1 I 1
r CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS 101-122B UT Satisfactory Limited Exam Due To Proximity To Outlet Nozzle. See Relief Request IR-l. 101-122C .UT Satisfactory Limited Exam Due To Proximity To Outlet Nozzle. See Relief Request IR-1. 101-124A UT Satisfactory None 101-124B UT Acceptable Code AllowableIndication. 101-124C UT Acceptable Code Allowable Indication. Plate Segregates in the Base :aaterial. 101 141 UT Satisfactory Limited Exam Due To Radial Support Lugs. See Relief Request IR-1. 101-142A UT Satisfactory Plate Segregates in the Base Material. 101 142B UT Satisfactory Plate Segregates in the Base Material. 101-142C UT Satisfactory Plate Segregates in the Base Material. 101-154A UT Satisfactory Limited Exam Due To intrumentation Tubes. See Relief Request IR-1. 101-154B UT Satisfactory Limited Exam Due To j Intrumentation Tubes. See Relief 6 Request IR-1. 101-154C UT Satisfactory Limited Exam Due To i intrumentation Tubes. See Relief Request IR-l. 101-154D UT Satisfactory Limited Exam Due To Intrumentation Tubes. See Relief Request IR-l. 101-171 UT Acceptable Code Allowable Indication. 102-151 UT Acceptable Code Allowable Indication. Limited Exam Due To intrumentation Tubes. See Relief Request IR-l. i 103 101 UT Satisfactory None 103-121 UT Acceptable Code Allowable Indication. B-s RCS i Report: rptNDEResultsSummary Page 10 of 41 Sorted: Cat / System /ReferencelD i i
.~ i i t i CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS j 03-003-SW-Z UT Satisfactory None 03-005-SW-Z UT Satisfactory None f 1 03-006-SW Z UT Satisfactory None SD RCS 03-003 SW-U(IR) UT Satisfactory None 4 03-003-SW-V(IR) UT Satisfactory None a 03-004-SW-U(IR) UT Satisfactory None 03-004-SW-V(IR) UT Satisfactory None l 03-005-SW-U UT Satisfactory None 1 I 03-005-SW-U(IR) UT Satisfactory None 03-005-SW-V UT Satisfactory None j 03-005-SW-V(IR) UT Satisfactory None 03-006-SW-U UT Satisfactory None { 03-006-SW-U(IR) UT Satisfactory None i 03-006-SW-V UT Satisfactory None 03-006-SW V(IR) UT Satisfactory None RPV 105-121-A-IR UT Satisfactory None 105-121-B-IR UT Satisfactory None 105-121-C-IR UT Satisfactory None 105-121-D-IR UT Satisfactory None 105-121 A UT Satisfactory Limited Tranverse Exam Due To Integral Extention. 105-121B UT Satisfactory Limited Tranverse Exam Due To Integral Extention. 105121C UT Acceptable Code Allowable Indication. Limited Tranverse Exam Due To Integral Extention. 105-121D UT Acceptable Code Allowable Indication. Limited Tranverse Exam Due To Integral Extention. 107-121 A-IR UT Satisfactory None 107121-B-lR UT Satisfactory None Report: rptNDEResultsSummary p, gg Sorted: Cat / System /ReferencelD
CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS 107-121-C IR UT Satisfactory None 107-121-D-lR UT Acceptable Code Allowable Indication. 107-121 A UT Satisfactory Limited Tranverse Exam Due To Integral Extention. 107-121B UT Satisfactory Limited Tranverse Exam Due To Integral Extention. 107-121C UT Satisfactory Limited Tranverse Exam Due To Integral Extention. i 107121D UT Satisfactory Limited Tranverse Exam Due To Integral Extention. Plate Segregates in Base Material. 7 B-E RCS 03-007-IITPW-01-XX VT-2 Satisfactory None l { B-F RCS RCS-LP2-FW-4 UT Satisfactory None PT Satisfactory None t RCS-LP2-FW-5 UT Satisfactory None f f l PT Acceptable None RPV 301 121-A UT Satisfactory None 301 121-B UT Satisfactory None 301-121-C UT Acceptable Geometric Reflector From Outer Blend Radius. r 301 121-D UT Acceptable Geometric Reflector From Outer j Blend Radius. 302-121-A UT Satisfactory None l 302-121-B UT Satisfactory None 302 121-C UT Satisfactory None l 302-121-D UT Satisfactory None f B-G-1 RPV 03-001-001-01 UT Satisfactory None i 03-001-001-02 UT Satisfactory None 03-001-001-03 UT Satisfactory None Report: rptNDEResultsSummary Page 12 of 41 Sorted: Cat /SystemIReferencelD
CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS 03-001-001-04 UT Satisfactory None 03-001-001-05 UT Satisfactory None 03-001-001-06 UT Satisfactory None 03-001-001-07 UT Satisfactory Ncne 03-001-001-08 UT Satisfactory None 03-001-001-09 UT Satisfactory None 03-001-001-10 UT Satisfactory None 03-001-001-11 UT Satisfactory None 03-001-001-12 UT Satisfactory None 03-001-001-13 UT Satisfactory None 03-001-001-14 UT Satisfactory None 03-001-001-15 UT Satisfactory None L 03-001-001-16 UT Satisfactory None 0.2-001-001-17 UT Satisfactory None 03-001-001-18 UT Satisfactory None L 03-001-001-19 UT Satisfactory None 03-001-001-20 UT Satisfactory None 03-001-001-21 UT Satisfactory None 03 001-001-22 UT Satisfactory None 03-001-001 23 UT Satisfactory None 03-001-001-24 UT Satisfactory None 03-001-001 25 UT Satisfactory None 03-001-001-26 UT Satisfactory None 03-001-001 27 UT Satisfactory None 03-001-001-28 UT Satisfactory None { 03-001-001-29 UT Satisfactory None 03-001-001-30 UT Satisfactory None 3._ 03-001-001-31 UT Satisfactory None 03-001-001-32 UT Satisfactory None 03-001-001-33 UT Satisfactory None Report: rptNDEResultsSumnwy Page 13 of 41 e Sorted: Cat / System /ReferencelD [ J l
I l CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS 03-001-001-34 UT Satisfactory None 03-001-001-35 UT Satisfactory None 03-001-001-36 UT Satisfactory None 03-001 001 37 UT Satisfactory None 03-001-001-38 UT Satisfactory None 03-001-001-39 UT Satisfactory None 03-001-001-40 UT Satisfactory None 03 001-001-41 UT Satisfactory None 03-001-001-42 UT Satisfactory None 03-001-001-43 UT Satisfactory None ' 03-001-001-44 UT Satisfactory None 03-001-001-45 UT Satisfactory None 03-001-001-46 UT Satisfactory None 03-001-001-47 UT Satisfactory None 03-001-001-48 UT Satisfactory None 03-001-001-49 UT Satisfactory None 03-001-001-50 UT Satisfactory None 03-001-001-51 UT Satisfactory None 03-001-001-52 UT Satisfactory None 03-001-001-53 UT Satisfactory None 03-001-001-54 UT Satisfactory None 179-101-01 UT Satisfactory None MT Satisfactory None 179-101-02 UT Satisfactory None MT Satisfactory None 179-101-03 UT Satisfactory None l MT Satisfactory None 179-101-04 UT Satisfactory None MT Satisfactory None 179-101-05 UT Satisfactory None MT Satisfactory None Report: rptNDEResultsSummary p g,g4,,49 Sorted: Cat / System /ReferencelD
1 l ] CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS r 179-101-06 UT Satisfactory None I MT Satisfactory None i l 179-101-07 UT Satisfactory None MT Satisfactory None I 179-101-08 UT Satisfactory None l l MT Satisfactory None t 179-101-09 UT Satisfactory None MT Satisfactory None 179-101-10 UT Satisfactory None MT Satisfactory None l I 179-101-11 UT Satisfactory None MT Satisfactory None 179-101-12 UT Satisfactory None i MT Satisfactory None 179-101-13 UT Satisfactory None MT Satisfactory None i ~ 179-101 14 UT Satisfactory None j MT Satisfactory None l 179-101 15 UT Satisfactory None MT Satisfactory None l 179-101-16 UT Satisfactory None MT Satisfactory None 179-101-17 UT Satisfactory None I MT Satisfactory None 179-101-18 UT Satisfactory None l MT Satisfactory None i t 179-101-19 UT Satisfactory None j f j MT Satisfactory None 179-101 20 UT Satisfactory None MT Satisfactory None 179-101-21 UT Satisfactory None l MT Satisfactory None 179-101-22 UT Satisfactory None MT Satisfactory None 179-101 23 UT Satisfactory None MT Satisfactory None I l Report: rptNDEResultsSummary Page 15 of 41 Sorted: Cat / System /ReferencelD I
- _ =. n CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS l 179-101-24 UT Satisfactory None MT Satisfactory None i 179 101-25 UT Satisfactory None MT Satisfactory None i f 179-101-26 UT Satisfactory None MT Satisfactory None j 179-101-27 UT Satisfactory None l MT Satisfactory None 179-101-28 UT Satisfactory None MT Satisfactory None 179-101-29 UT Satisfactory None MT Satisfactory None 179-101-30 UT Satisfactory None MT Satisfactory None 7 179-101-31 UT Satisfactory None MT Satisfactory None 179 101-32 UT Satisfactory None MT Satisfactory None 179-101-33 UT Satisfactory None MT Satisfactory None 179-101 34 UT Satisfactory None MT Satisfactory None i' 179-101-35 UT Satisfactory None MT Satisfactory None i 179-101-36 UT Satisfactory None MT Satisfactory None t 179-101 37 UT Satisfactory None MT Satisfactory None l 179-101-38 UT Satisfactory None MT Satisfactory None 179-101 39 UT Satisfactory None a MT Satisfactory Nonc 179-101-40 UT Satisfactory None MT Satisfactory None 179-101-41 UT Satisfactory None MT Satisfactory None l 1 f Report: rptNDEResuksSummary Page 16 of 41 Sorted: Cet/ System /ReferencelD o
CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS 179-101-42 UT Satisfactory None MT Satisfactory None 179-101-43 UT Satisfactory None MT Satisfactory None 179-101-44 UT Satisfactory None MT Satisfactory None 179-101-45 UT Satisfactory None f MT Satisfactory None F 179-101-46 UT Satisfactory None j MT Satisfactory None i -f 179-101-47 UT Satisfactory None MT Satisfactory None 179-101-48 UT Satisfactory None MT Satisfactory None 179-101-49 UT Satisfactory None l MT Satisfactory None f 179-101 50 UT Satisfactory 'None MT Satisfactory None i 179-101 51 UT Satisfactory None MT Satisfactory None 179-101 52 UT Satisfactory None MT Satisfactory None 179-101-53 UT Satisfactory None i MT Satisfactory None l 179-101-54 UT Satisfactory None MT Satisfactory None B-G-2 l HSI f f 407250-FLANGE VT-1 Satisfactory None i i RcS l 03-006-001 VT-1 Satisfactory None l 03-006-002 VT-1 Satisfactory None 03-006-003 VT-1 Satisfactory None 03-006-004 VT-1 Satisfactory None FE-438 VT-l Satisfactory None j FE-448 VT-1 Satisfactory None Report: rptNDEResultsSummary p,9, g7 og 49 Sorted: Cat / System /ReferencelD 4 a
i I CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS t RCS-513 3-FLANGE VT1 Acceptable One Bolt Less Than Fully Engaged By One Thread. Nuts And Bolting inspected in Place, Under Tension I RCS-513-4-FLANGE VT-1 Satisfactory None RCS-V-102 VT-1 Satisfactory None RCS-V-128 VT-1 Satisfactory None RCS-V-129 VT-1 Satisfactory None RCS-V-132 VT-1 Satisfactory None i' RCS-V-53 VT-1 Satisfactory None RCS-V 87 VT-1 Acceptable Dry Boron Approx 90 Deg. Around Gasket Seating Area. Bolts And Nuts inspected in Place, Under Tension t RHS I RilS-V 998 VT-1 Satisfactory None SIL RCS-V-107 VT-1 Satisfactory None RCS V-142 VT-1 Satisfactory None RCS-V-30 VT-1 Satisfactory None SIL-V-15 VT-1 Satisfactory None l SIL-V-17 VT-1 Acceptable Studs And Nuts Inspected in Place i Under Tension. Light Boron Deposits 90 Degree Around Mating Surface SIL-V-19 VT-1 Satisfactory None SIL-V-26 VT-1 Satisfactory None SIL-V 28 VT-1 Satisfactory None SIL-V 69 VT-1 Satisfactory None SIL-V 71 VT-1 Acceptable Studs And Nuts Inspected in Flace, Under Tension. Evidence Of Boron 360 Degree Around Mating Surface SIL-V-932 VT-1 Acceptable Studs And Nuts Were Inspected in Place, Under Tension. Evidence Of Leakage At Valve Stem Packing Area SIL-V-986 VT-1 Satisfactory None Report: rptNDEResuksSummery Page 18 of 41 Sorted: Cet/ System /ReferencelD
. _ ~ =- CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS SIL-V-987 VT-1 Acceptable 16 Studs And Nuts Inspected In Place B-J CHS 3-CllS-14-FW-26 PT Satisfactory None 3-CllS-14-FW-7 PT Satisfactory None 374019-FW-17 PT Satisfactory None 374019-FW-23 PT Satisfactory None DRN 407327-FW-4 PT Satisfactory None 408001-FW-1 PT Satisfactory None 408001-FW-10 PT Satisfactory None t 408001 FW-2 PT Satisfactory None l 408001-FW-4 PT Satisfactory None 408001 FW-5 PT Satisfactory None t 408001-FW-6 PT Satisfactory None 408001 FW-7 PT Satisfactory None 408001-FW-8 PT Satisfactory None s 408001-FW-9 PT Satisfactory None HSI 407250-FW-3 PT Satisfactory None 407250-FW-4 PT Satisfactory None 407250-FW-42 PT Satisfactory None 407250-FW-5 PT Satisfactory None 407250-FW-7 PT Satisfactory None i 407250-FW-8 PT Satisfactory None i 407250-FW-9 PT Satisfactory None 408044-FW-3 PT Satisfactory None 408044-FW-5 PT Satisfactory None 408045-FW-5 PT Satisfactory None S!ll-144-FW 12 PT Satisfactory None i Sill-144-FW-13 PT Satisfactory None Report: rptNDEResultsSummery p,, g g Sorted: Cet/ System /ReferencelD
l 4 CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMM EN*n'S Sill-144-FW-27 PT Satisfactory None Sill-144-FW-28 PT Satisfactory None Sill-501-4-SW-3 PT Satisfactory None Sill-501-FW-5 PT Satisfactory None RCS 3-CilS-14 FW-ll PT Satisfactory None 3-CilS-14-FW-12 PT Satisfactory None 3-CllS-14-FW-19 PT Satisfactory None 3-CilS-14-FW-20 PT Satisfactory None 3-CllS-14-FW-21 PT Satisfactory None 3-CilS-14-FW-22 PT Satisfactory None 3-CilS-14-FW-23 PT Satisfactory None s 3-CllS-14-FW-24 PT Satisfactory None 3-CilS-14-FW-8 PT Satisfactory None 3-CilS-14-FW-9 PT Satisfactory None 3-CliS-15-FW-15 PT Satisfactory None 374077-FW-11 PT Satisfactory Non: i 374077-FW-2 PT Satisfactory None 374077-FW-4 PT Satisfactory None 374077-FW-7 PT Satisfactory None 374077-FW-8 PT Satisfactory None 374079-FW-1 PT Satisfactory None 374079 FW-4 PT Satisfactory Nor.e 374079-FW-5 PT Satisfactory Nene 374079-FW-7 PT Satisfactory None 374079-FW-8 PT Satisfactory None 374079-FW-9 PT Satisfactory None 408013-FW-1 PT Satisfactory None 408013-FW-12 PT Satisfactory None 408013-FW-2 PT Satisfactory None 408013-FW 3 PT Satisfactory None Report: rptNDEResultsSummary Page 20 of 41 Sorted: Cat / System /ReferencelD
CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS 408013-FW-6 PT Satisfactory None 408013-FW-7 PT Satisfactory None 408044-FW-10-1 PT Satisfactory None 408045-FW-4 PT Acceptable None RCS-10-FW-23 PT Satisfactory None RCS-10-FW-25-1 PT Satisfactory None RCS-15-FW-33 PT Satisfactory Ncne i RCS-15-FW-35-1 PT Satisfactory None RCS-15-FW-37 PT Satisfactory None RCS-20-FW-43-1 PT Satisfactory None RCS-20-FW-45-1 PT Satisfactory None L RCS-20-FW-46-1 PT Satisfactory None 1 RCS-504-7-SW-3 UT. Satisfactory None PT Satisfactory None RCS-506-3-SW-4 PT Acceptable None RCS-506-4-SW-2 PT Satisfactory None RCS-507-2-SW-2 PT Satisfactory None RCS-507-3-SW-2 PT Satisfactory None RCS-507-4-SW-3 PT Satisfactory None RCS-507-4-SW-4 PT Satisfactory None RCS-507-4-SW 5 PT Satisfactory None RCS-507-4-SW-6 PT Satisfactory None RCS-507-FW-1 PT Satisfactory None RCS-507-FW-2 PT Satisfactory None RCS-507-FW-3 PT Satisfactory None RCS-507-FW-5 PT Satisfactory None RCS-508-1-SW-2 UT Satisfactory None PT Satisfactory None RCS-508-1-SW-3 UT Satisfactory None PT Satisfactory None RCS-517 FW-2 UT Acceptable Geometry PT Satisfactory None Report; rptNDEResultsSummary p,, y g Sorted: Cat / System /ReferencelD
- CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS RCS-LP3-FW-26 UT Satisfactory None PT Satisfactory None RCS-LP3-FW-27 UT Satisfactory None PT Satisfactory None RCS-LP3-ilL2-SW-C PT Satisfactory None RCS-LP3-ilL2-SW-D PT Satisfactory None RCS-LP3-ilL2-SW-E PT Satisfactory None RCS-LP3-ilL2-SW-G PT Satisfactory None SIL-4-FW il UT Satisfactory None PT Satisfactory None SIL-5-6-SW-B UT Satisfactory None PT Satisfactory None SIL-5-FW-10 UT Satisfactory None PT Satisfactory None SIL SIL-13-3-SW-B UT Satisfactory None PT Satisfactory None SIL-13-3-SW-C UT Satisfactory None PT Satisfactory None SIL-13-3-SW-D UT Satisfactory None PT Satisfactory None SIL-13-3-SW-G UT Satisfactory None PT Satisfactory None SIL-13-FW-3E-M UT Satisfactory None PT Satisfactory None SIL-4-FW-7 UT Satisfactory None PT Satisfactory None SIL-4-FW-8 UT Satisfactory None PT Satisfactory None SIL 5-5-SW-B UT Satisfactory None PT Satisfactory None SIL-5-5-SW-G UT Satisfactory None PT Satisfactory None SIL-507-2-SW-6 PT Satisfactory None SIL-507-4-SW-3 UT Satisfactory None PT Satisfactory None Report: rptNDEResultsSunwy Page 22 of 41 Sorted: Cet/ System!ReferencelD
l i CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS SIL-507-4-SW-4 UT Satisfactory None i PT Satisfactory None i B-K-1 RCS RCS-504D-PSSil500 PT Satisfactory None RCS-504D-PSSil501 PT Satit. factory None B-N-I J RPV 03-001-003 VT-3 Acceptable Three Foreign Objects Found in Lower llead During Debris Scan. B-N-2 RPV 143-101A VT-3 Satisfactory None 143-101B VT-3 Satisfactory None 143-101C VT-3 Satisfactory None 143-101D VT-3 Satisfactory None 143-10lE VT-3 Satisfactory None 143-10lF VT-3 Satisfactory None INTERIOR ATTACil.0/BL VT-3 Satisfactory Examined Interior Attachments Beyond Beltline Region. B N-3 RPV LOWER INTERNALS VT-3 Acceptable Foreign Material Encountered on l Barrel Flange i 1 UPPER INTERNALS VT-3 Satisfactory None B-P RCS CLASS I PIPING (1) VT-2 Satisfactory None l CLASS I VALVES (1) VT-2 Acceptable Normal Leakage Found PRESSURIZER (1) VT-2 Satisfactory None REACTOR COOLANT PUMP (I VT-2 Satisfactory None REACTOR VESSEL (1) VT-2 Satisfactory None l STEAM GENERATORS (1) VT2 Satisfactory None C-A MS Report: rptNDEResultsSummary p g Sorted: Cat / System /ReferencelD
CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS 03-053-SW-CL UT Acceptable 0.15" Deep by 1.05" Long Planer Reflector. 03-053-SW-P UT Satisfactory None 03-053-SW-Y UT Satisfactory None C-B RilS 03-073-001 PT Acceptable Three Rounded Indications Found at Weld Toe 03-073-003 PT Acceptable 8 Indications Found With Lengths Between 3/32" to 7". Evaluated After Determining Depth With ECT. C-C HSI 3-CilS-2-PSR033 PT Satisfactory None QSS 3-QSS-4-PSSH067 PT Satisfactory None 3-QSS-4-PSSill li PT Acceptable 0.125" Rounded Pinhole at Weld Toe on Intergral Attaccments. l R11S RilS-PI A-L1 PT Satisfactory None RilS-PI A-L2 PT Satisfactory None RilS-PI A L3 PT Satisfactory None i RSS 3-RSS-4-PSSill61 PT Satisfactory None l C-D MS M SS-V-7 UT Satisfactory None C-F-l QSS QSS-1-1 LS-3 UT Satisfactory None PT Satisfactory None QSS-1-1-LS-6 UT Satisfactory None PT Satisfactory None QSS-1 1-SW-E UT Satisfactory None PT Satisfactory None QSS-1-1 SW-F UT Satisfactory None l PT Satisfactory None Report: rptNDEResuksSummary Page 24 of 41 Sorted: Cet/ System /ReferencelD
CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS QSS-1-1-SW-G UT Satisfactory None PT Satisfactory None QSS-3-4-LS-2 UT Satisfactory None PT Satisfactory None QSS-3-4-LS-3 UT Satisfactory None PT Satisfactory None QSS-3-4-LS UT Satisfactory None PT Satisfactory None j QSS-3-4-SW-K UT Acceptable Geometry i PT Satisfactory None QSS-3-5-LS-1 UT Satisfactory None PT Satisfactory None l, QSS-3-FW-4R-MR UT Satisfactory None [ PT Satisfactory None QSS-3 FW-5BR UT Acceptable Geometry PT Satisfactory None QSS-3-FW-5CR UT Satisfactory None PT Satisfactory None f QSS-5-2-LS-6 UT Satisfactory None l PT Satisfactory None QSS-5-2-LS-7 UT Satisfactory None PT Satisfactory None QSS-5-2-SW-C UT Satisfactory None PT Satisfactory None QSS-6-3-SW-D UT Satisfactory None PT Satisfactory None QSS-6-4 SW B UT Satisfactory None PT Satisfactory None QSS-6-4-SW-C UT Satisfactory None PT Satisfactory None QSS-6-4-SW D UT Satisfactory None PT Satisfactory None QSS-6-FW-1 UT Satisfactory None PT Satisfactory None RHS RHS-501-FW-6 UT Satisfactory None PT Satisfactory None Report: rptNDEResultsSum Page 25 of 41 Sorted: Cet/ System /ReferencelD
CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS RilS-502-5-SW-3 UT Satisfactory None PT Satisfactory None RilS-502-FW-7 UT Satisfactory None PT Satisfactory None RilS-502-FW 8 UT Satisfactory None PT Satisfactory None RilS-7-6-LS-16 UT Satisfactory None PT Satisfactory None RilS-7-7-LS-18 UT Satisfactory None PT Satisfactory None RilS-7-FW-8 UT Acceptable Geometry PT Satisfactory None RSS RSS-I-3-SW-B UT Satisfactory None PT Satisfactory None RSS-16-1 LS-2 UT. Satisfactory None PT Satisfactory None RSS-16-1-LS-3 UT Satisfactory None PT Satisfactory None RSS-16-1-LS-6 UT Satisfactory None PT Satisfactory None f RSS-16-1-SW-B UT Satisfactory None PT Acceptable 1/8" Transverse Linear Indication Located 12 3/4" RSS-16-1-SW-C UT Satisfactory None PT Satisfactory None l i j RSS-16-1 SW-D UT Satisfactory None l PT Satisfactory None l RSS-16-1 SW-E UT Satisfactory None l PT Satisfactory None I RSS 16-2 SW-B UT Satisfactory None ) PT Acceptable Rounded (0.070") At 3" For 'O' ) Datum 1 j RSS-16-FW-2-1 UT Satisfactory None i PT Satisfactory None RSS-16-FW-3 UT Satisfactory None PT. Satisfactory None j a Report: rptNDEResultsSummary Page 26 of 41 Sorted: Cat / System /ReferencelD
i CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS RSS-21-4-LS-37 UT Satisfactory None PT Satisfactory None RSS-21-4-LS-38 UT Satisfactory None PT Satisfactory None RSS-21-4-SW-G UT Satisfactory None PT Acceptable 3 Round Pits Form An 1/8" Diameter Bleedout RSS-6T-1 LS-3 UT Satisfactory None PT Satisfactory None RSS-6T-1-LS-4 UT Satisfactory None PT Satisfactory None RSS-6T-1-SW-B UT Satisfactory None PT Satisfactory None RSS-6T-1-SW-C UT Satisfactory None PT Satisfactory None RSS-6T-FW-1 UT Satisfactory None PT Satisfactory None RSS-6T-FW-2-1 UT Satisfactory None 3 PT Satisfactory None RSS-8-2-LS-38 UT Satisfactory None PT Satisfactory None RSS-8-2-LS-39 UT Satisfactory None PT Satisfactory None RSS-8-2-SW-R UT Satisfactory None PT Satisfactory None SIL SIL-152A-FW-1 UT Satisfactory None PT Satisfactory None SIL-152A-FW-2-3M UT Repaired Removed a 0.3" Long Linear and Several Rounded Indications By Grinding. PT Satisfactory None SIL-25-FW-1-SM UT Satisfactory None PT Satisfactory None SIL-25-FW 1-6M UT Satisfactory None PT Satisfactory None SIL-25-FW-1-7M UT Satisfactory None PT Satisfactory None Report: rptNDEResultsSummary Page 27 of 41 Sorted: Cat / System /ReferencelD
CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS SIL-25-FW-1 8M UT Satisfactory None i PT Satisfactory None SIL-25-FW-2 UT Satisfactory None I f PT Satisfactory None i SIL-25-FW-3 UT Satisfactory None i i PT Satisfactory None i i SIL-508-2 LS-15 UT Satisfactory None PT Satisfactory None 4 l SIL-508-2-LS-16 UT Satisfactory None i PT Satisfactory None 1 SIL 508 2-LS-17 UT Satisfactory None i r. PT Satisfactory None SIL-508-2-LS-18 UT Satisfactory None l PT Satisfactory None i SIL-9-1-LS-1 UT Satisfactory None PT Satisfactory None i e SIL-9-1-LS-3 UT Satisfactory None l PT Satisfactory None l l SIL-9-1 LS-4 UT Satisfactory None f PT Satisfactory None i l SIL-9-1 LS-5 UT Satisfactory None l PT Satisfactory None ii SIL-9-1-LS-6 UT Satisfactory None j PT Satisfactory None l ) SIL-9-1 SW-D UT Satisfactory None PT Satisfactory None SIL-9-1-SW-F UT Satisfactory None [ PT Satisfactory None j l SIL-9-5-LS-39 UT Satisfactory None PT Satisfactory None SIL-9-5-LS-40 UT Satisfactory None i 4 PT Satisfactory None 1 SIL-9 5-SW-C UT Satisfactory None PT Acceptable None SIL-9-6-LS-20 UT Satisfactory None j PT Satisfactory None { l l Report: rptNDEResultsSummary p gg Sorted: Cat / System /ReferencelD i ... ~. -.
CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS r Sil 9-6-LS-20A UT Satisfactory None PT Acceptable 2 Indications,each less than 1/16" in length r SIL-9-7-LS-21 UT Satisfactory None PT Satisfactory None SIL-9-7-SW-B UT Acceptable Geometry PT Satisfactory None SIL.9-8-LS-26 UT Satisfactory None PT Satisfactory None SIL-9T-FW-11 UT Satisfactory None PT Satisfactory None SIL-9T-FW-16 UT Satisfactory None PT Satisfactory None SIL-9T-FW-lE-M UT Satisfactory None PT Satisfactory None i j SIL-9T-FW-46-1 UT Satisfactory Nonc i PT Satisfactory None C-F-2 FWA FWA-509-6-SW-2 UT Satisfactory None MT Acceptable 14 Indications From 3/16"io 1 4 5/16" in Length Caused By 7 i Scoring on Surface of Pipe, i FWS I FWS-13-FW-7-JM^ UT Satisfactory None MT Satisfactory None FWS-21 -FW-l ^^ UT Satisfactory None MT Satisfactory None FWS-22-FW-l ^^ UT Satisfactory None MT Satisfactory N. FWS-24-FW-l ^^ UT Satisfactory None MT Satisfactory None FWS-25-5-SW-D^ UT Satisfactory None MT Satisfactory None FWS-25-5-SW E^ UT Satisfactory None i MT Satisfactory None l MS Report: rptNDEResultsSummary Pay 29 oN Sorted: Cat / System /ReferencelD i
l i CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS MSS-34-FW-1-LS-l M^ UT Satisfactory None MT Satisfactory None MSS-34-FW-1-LS-6M^ UT Satisfactory None MT Satisfactory None l MSS-34-FW-1-LS-7M^ UT Satisfactory None MT Satisfactory None MSS-34-FW-1-XM ^ MT Satisfactory None MSS-34-FW-1-ZM^ MT Satisfactory None MSS-34-FW l^ UT Satisfactory None MT Satisfactory None MSS-34-FW-2-G M^ UT Satisfactory None MT Satisfactory None MSS-34-FW-2^ UT Satisfactory None MT Satisfactory None MSS-502-FW-6^ UT Satisfactory None l MT Satisfactory None MSS-503-FW-4^ UT Satisfactory None MT Satisfactory None C-G MS MSS-34-FW-V4 5M MT Satisfactory None C-il CilS INSERVICE TEST (CilS) VT-2 Repaired Thru-Wall Leakage From Socket Welded Joint. FWA FUNCTIONAL TEST (FWA-1) VT-2 Satisfactory None FWS INSERVICE TEST (FWS) VT-2 Satisfactory None MS l INSERVICE TEST (MS) VT-2 Satisfactory None QSS FUNCTIONAL TEST (QSS) VT-2 Satisfactory None RilS FUNCTIONAL TEST (RilS) VT-2 Satisfactory None RSS Report: rptNDEResulteSummary Page 30 of 41 Sorted: Cat / System /ReferencelD
CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS FUNCTIONAL TEST (RSS) VT-2 Satisfactory None SIL FUNCTIONAL TEST (SIL) VT-2 Satisfactory None D-A FWA 3-FWA-4 PSR194 VT-3 Satisfactory None FUNCTIONAL TEST (FWA-2) VT-2 Satisfactory None l D-B CCE FUNCTIONAL TEST (CCE) VT-2 Satisfactory None CCI FUNCTIONAL TEST (CCl) VT-2 Satisfactory None CCP 3-CCP-1 PSA008 VT-3 Satisfactory None 3-CCP-1-PSA017 VT-3 Satisfactory None 3-CCP-1-PSA025 VT-3 Satisfactory None 3-CCP-1-PSA045 VT-3 Satisfactory None 3-CCP-1-PSA162 VT-3 Satisfactory None I 3-CCP-1-PSA316 VT-3 Satisfactcary None 3-CCP-1-PSR001 VT-3 Satisfactory None 3-CCP-1 PSR029 VT-3 Satisfactory None 3-CCP l-PSR031 VT-3 Satisfactory None 3-CCP-1 PSR315 VT-3 Satisfactory None 3-CCP-1-PSR317 VT-3 Satisfactory None 3-CCP-2-PSA050 VT-3 Satisfactory None 3-CCP-2-PSA056 VT-3 Satisfactory None 1 3-CCP-2-PSR012 VT-3 Satisfactory None 3-CCP 2-PSR014 VT-3 Satisfactory None 3-CCP-2-PSR062 VT-3 Satisfactory None 3 3-CCP-2-PSRl99 VT-3 Satisfactory None 3-CCP-2-PSR223 VT-3 Satisfactory None 3-CCP-2-PSR292 VT-3 Satisfactory None Report: rptNDEResultsSummary p g,g Sorted: Cet/ System /ReferencelD 1
CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS 3-CCP-2-PSSli205 VT-3 Satisfactory None 3-CCP-2-PSST 407 VT-3 Satisfactory None INSERVICE TEST (CCP) VT-2 Satisfactory None 7 EGF 4 FUNCTIONAL TEST (EGF) VT-2 Satisfactory None l SWP FUNCTIONAL TEST (SWP) VT-2 Satisfactory None D-C SFC FUNCTIONAL TEST (SFC) VT-2 Satisfactory None F-A RHS 3-RilS-SUP-I A VT-3 Satisfactory None F-B CCP 3-CCP-1 PSA025^ VT-3 Satisfactory None 3-CCP-1-PSA045^ VT-3 Satisfactory None 3-CCP-1 PSA316^ VT-3 Satisfactory None 3-CCP-1-PSR027 VT-3 Satisfactory None [ 3-CCP-l-PSR028 VT-3 Satisfactory None 3-CCP-1 PSR030 VT-3 Satisfactory None 3-CCP-1-PSR032 VT-3 Satisfactory None s 3-CCP-1-PSR033 VT-3 Satisfactory None 3-CCP-1-PSR034 VT-3 Satisfactory None j 3-CCP-1 PSR044 VT-3 Satisfactory None j 3-CCP-1-PSR312 VT-3 Satisfactory Nonc 3-CCP-1-PSR313 VT-3 Satisfactory None 3-CCP-1-PSR314 VT-3 Satisfactory None 3-CCP-1-PSR315^ VT-3 Satisfactory None l l 3-CCP-1-PSR317^ VT-3 Satisfactory None I 3-CCP-1-PSR318 VT-3 Satisfactory None 3-CCP-2-PSR002 VT-3 Satisfactory None l t 3-CCP-2-PSR004 VT-3 Satisfactory None Report: rptNDEResultsSummary p ggy Sorted: Cat / System /ReferencelD I
_.. ~ _ _.. CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS 3-CCP-2-PSR007 VT-3 Satisfactory None 3-CCP-2-PSR012^ VT-3 Satisfactory None 3-CCP-2-PSR013 VT-3 Satisfactory None i 3-CCP-2-PSR014^ VT-3 Satisfactory None q 3-CCP-2-PSR062^ VT-3 Satisfactory None i 3-CCP-2-PSR112 VT-3 Satisfactory None 3-CCP-2-PSR199^ VT-3 Satisfactory None -j 3-CCP-2-PSR268 VT-3 Satisfactory None 3-CCP-2-PSR292^ VT-3 Satisfactory None l DRN 3-RCS-I-PSR437 VT-3 Satisfactory None [ FWA 3 FWA-1-PSA027^ VT-3 Satisfactory None 3-FWA-1-PSR026 VT-3 Satisfactory None 3-FWA-1-PSR028 VT-3 Satisfactory None 3-FWA-1-PSR029 VT-3 Satisfactory None i 3-FWA-1. PSR030 VT-3 Satisfactory None i 3-FWA-1-PSR031 VT-3 Satisfactory None 1 f 3-FWA-1-PSR032 VT-3 Satisfactory None 3-FWA-4-PSR 194 ^ VT-3 Satisfactory None l 3-FWA-4-PSR221 VT-3 Satisfactory None t ? 3-FWA-4-PSR322 VT-3 Satisfactory None FWS l 3-FWS-4-PSR0l S VT-3 Satisfactory None [ 3-FWS-4-PSR021 VT-3 Satisfactory None i 3-FWS-4-PSR028 VT-3 Satisfactory None 3-FWS-4-PSR030 VT-3 Satisfactory None j 3-FWS-4-PSR032 VT-3 Satisfactory None f 3-FWS-4-PSR034 VT-3 Satisfactory None i 3-FWS-4-PSR055 VT-3 Satisfactory None { 11S1 [ l Report: rptNDEResultsSummary Page 33 of 41 Sorted: Cat / System /ReferencelD I w,
i CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS 3-Sill 1-PSA347 VT-3 Satisfactory None 3-Sill-1 PSA365 VT-3 Satisfactory None 3-SIII-1-PSA373 VT-3 Satisfactory None 3-Sill 1 PSA391 VT-3 Satisfactory None 3-Sill-1-PSR100 VT-3 Satisfactory None 3-Sill-1-PSR101 VT-3 Satisfactory None 3 Sill-1 PSR102 VT-3 Satisfactory None 3-Sill-1-PSR103 VT-3 Satisfactory None 3-Sili 1 PSR104 VT-3 Satisfactory None 3-Sill-1-PSR105 VT-3 Satisfactory None 3-Sill 1-PSR1072 VT-3 Satisfactory None 3-Sill-1-PSR1073 VT-3 Satisfactory None 3-Sill-1-PSR1074 VT-3 Satisfactory None 3-Sill-1-PSR1075 VT-3 Satisfactory None 3-Sill-1-PSR344 VT-3 Satisfactory None 3-Sill-1 PSR361 VT-3 Satisfactory None 3-Sill 1 PSR362 VT-3 Satisfactory None 3-Sill-1-PSR363 VT-3 Satisfactory None 3-Sill-1-PSR364 VT-3 Satisfactory None 3-Sill-1-PSR366 VT-3 Satisfactory None 3-Sill-1-PSR368 VT-3 Satisfactory None 3-Sill-1-PSR369 VT-3 Satisfactory None 3-Sill 1-PSR370 VT-3 Satisfactory None 3-Sill-1 PSR371 VT-3 Satisfactory None 3-Sill-1 PSR372 VT-3 Satisfactory None 3-Sill-1-PSR374 VT-3 Satisfactory None t 3-Sill-1 PSR375 VT-3 Satisfactory None i 3-Sill-1 PSR376 VT-3 Satisfactory None j l 3-S!!I-1-PSR387 VT-3 Satisfactory None l 3-Sill-1 PSR389 VT-3 Satisfactory None Report: rptNDEResultsSummary p yg Sorted: Cat / System /ReferencelD
CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS 3-SlH-1-PSR390 VT-3 Satisfactory None MS 3-MSS-4-PSR031 VT-3 Satisfactory None 3 MSS-4-PSR011 VT-3 Satisfactory None 3-MSS-4-PSR013 VT-3 Satisfactory None 3-MSS-4-PSR026 VT-3 Satisfactory None 3-MSS-4-PSR040 VT-3 Satisfactory None 3-MSS-4-PSR052 VT-3 Satisfactory None 3 MSS-4-PSR053 VT-3 Satisfactory None 3-MSS-4 PSRil2 VT-3 Satisfactory None QSS 3-QSS-4-PSR063 VT-3 Satisfactory None 3-QSS-4-PSR064 VT-3 Satisfactory None 3-QSS-4-PSR065 VT-3 Satisfactory None 3-QSS-4-PSR066 VT-3 Satisfactory None 3-QSS-4-PSR070 VT-3 Satisfactory None 3-QSS-4 PSRil2 VT-3 Satisfactory None 3-QSS-4-PSRi l3 VT-3 Satisfactory None 3-QSS-4-PSRl l7 VT-3 Satisfactory None t 3-QSS-4-PSR129 VT3 Satisfactory None 3-QSS-4-PSR130 VT-3 Satisfactory None RCS 3-RCS-1-PSR052 VT-3 Repaired Tighten Nuts 3-RCS-1-PSR057 VT-3 Satisfactory None j 3-RCS-1-PSR1549 VT-3 Satisfactory None 3-RCS-1-PSR1550 VT-3 Satisfactory None 3-RCS-1-PSRl551 VT3 Satisfactory None 1 3-RCS-1-PSR1552 VT-3 Satisfactory None 1 3-RCS-1-PSR458 VT3 Satisfactory None ( 3-RCS-1 PSR459 VT-3 Satisfactory None 3-RCS-1-PSR460 VT-3 Satisfactory None Report: rptNDEResultsSummy Page 35 of 41 Sorted: Cet/ System /ReferencelD
i 5 CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS l l 3-RCS-1 PSR461 VT-3 Satisfactory None 3-RCS-1-PSR462 VT-3 Satisfactory None RHS. 3 3-RilS-1-PSR013 VT-3 Satisfactory None j l 3-RilS-4-PSR017 VT-3 Satisfactory None l RSS 3-RSS-4-PSRl58 VT-3 Satisfactory None i 3-RSS-4-PSR163 VT-3 Satisfactory None 3 RSS-4-PSR167 VT-3 Satisfactory None SlH 3-Sill-1-FSAl40 VT-3 Satisfactory None 1 3-Sill-1-PSA348 VT-3 Satisfactory None 3-Sill-1-PSA569 VT-3 Satisfactory None 3-Sill-1-PSR141 VT-3 Satisfactory None 1 3-Sill 1-i'SR343 VT-3 Satisfactory None 3-Sill-1-PSR567 VT-3 Satisfactory None 3-Sill-1 PSRS68 VT-3 Satisfactory None j 3-Sill-1 PSR570 VT-3 Satisfactory None P 3-Sill-1-PSR571 VT-3 Satisfactory None l 3-Sill-1 PSR638 VT-3 Satisfactory None j l SIL 3-SIL-1-PSR037 VT-3 Satisfactory None I 3-SIL-t PSR038 VT-3 Satisfactory None j 3-SIL-1-PSR359 VT-3 Satisfactory None j 3-SIL-4-PSA067 VT-3 Satisfactory None 1 i 3-SIL-4-PSR048 VT-3 Satisfactory None 3-SIL-4-PSR049 VT-3 Satisfactory None SWP l 3-SWP-2-PSR048^ VT-3 Satisfactory None 3-SWP-2-PSR051 VT Satisfactory None 3-SWP-2-PSR060 VT-3 Satisfactory None l 3-SWP-2-PSR061 VT-3 Satisfactory None Report: rptNDEResultsSummary Sorted: Cat / System /ReferencelD
CATEGORY SYSTEM REFERENCEID EXAMS DISPOSITION COMMENTS j 3-SWP-4-PSR110 VT-3 Satisfactory None 3-SWP-4-PSRi l4 VT-3 Satisfactory None 1 3-SWP-4-PSRi l 5 VT-3 Satisfactory None F-C CCP 3-CCP-1 PSR018 VT-3 Satisfactory None 3-CCP-1-PSR029^ VT-3 Repaired Tighten Locknuts 3-CCP-1-PSR031^ VT-3 Satisfactory None 3-CCP-1-PSR 1052 VT-3 Satisfactory None 3-CCP-1-PSST 327 VT-3 Satisfactory None 3-CCP-2-PSR055 VT-3 Satisfactory None 3-CCP-2-PSR267 VT-3 Satisfactory None 3-CCP-2-PSR421 VT-3 Satisfactory None 3-CCP-2-PSSil259 VT-3 Satisfactory None 3-CCP-2-PSST 005 VT-3 Satisfactory None 3-CCP-2-PSST 008 VT-3 Satisfactory None 3-CCP-2-PSST 018 VT-3 Satisfactory None 3-CCP-2-PSST 407^ VT-3 Satisfactory None 3-CCP-2-PSST 408 VT-3 Satisfactory None CilS 3-CllS-1-PSST 739 VT-3 Satisfactory None DRN 3-RCS-1-PSS111062 VT-3 Repaired Tighten Loose Nuts 3-RCS-I-PSSill24 VT-3 Satisfactory None 3-RCS-I-PSSill27 VT-3 Satisfactory None 3-RCS-1-PSSil438 VT-3 Repaired Tighten Loose Nuts 1 FWA 3-FWA-1-PSST 033 VT-3 Satisfactory None FWS 3-FWS-4-PSR007 VT-3 Satisfactory None 3-FWS-4-PSR010 VT3 Repaired Tighten Nuts 3-FWS-4-PSR057 VT-3 Satisfactory None Report: rptNDEResultsSummary p,g,37,,49 Sorted: Cat / System /ReferencelD j
CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS IISI 3-Sill 1-PSRil71 VT-3 Satisfactory None e 3-Sill 1-PSR345 VT-3 Satisfactory None 3-Sill-1-PSR346 VT-3 Satisfactory None 3 Sill 1-PSST 367 VT-3 Satisfactory None 3-Sill-1-PSST 377 VT-3 Satisfactory None ~ 3-Sill-1 PSST 386 VT-3 Satisfactory None i 3-Sill-1-PSST 388 VT-3 Satisfactory None i MS 3-MSS-1-PSSill28 VT-3 Satisfactory Only Area Under Repair Was Inspected. i 3-MSS-1-PSSill29^ VT-3 Repaired Main Piviot Tabs Gouged From Contacting Jam Nut 3 MSS-4-PSR025 VT 3 Satisfactory None 3-MSS-4-PSS11012 VT3 Repaired Reset Spring Can Setting 3-MSS-4-PSST 036 VT3 Satisfactory None QSS 3-QSS-4-PSR062 VT-3 Acceptable Jam Nuts Are Missing From The Pipe Side Of The Threaded Rod-i To-Strut Connection 3-QSS-4-PSSIl067^ VT-3 Satisfactory None 3-QSS-4-PSS11111^ VT-3 Satisfactory None 3-QSS-4-PSST 060 VT-3 Satisfactory None 3-QSS-4-PSST 061 VT-3 Acceptable Jam Nuts Missing On Both Sides At Threaded Rod To Strut 3-QSS-4-PSST 068 VT-3 Satisfactory None 3-QSS-4-PSST 069 VT-3 Satisfactory None 4 3-QSS-4-PSST 071 VT-3 Satisfactory None 3-QSS-4-PSSTi l5 VT-3 Satisfactory None RCS 3-RCS-1-PSR018 VT-3 Satisfactory None 3-RCS-1-PSR042 VT-3 Satisfactory None 3-RCS-1-PSR049 VT-3 Repaired Tighten Locknut and Set Restraint 3-RCS-1-PSR050 VT-3 Satisfactory None Report: rptNDEResultsSumm Page 38 of 4 sort.d: cat /syet.m/ Refer.nc.co
I l l i CATEGORY SYSf EM REFERENCEID EXAMS DISPOSITION COMMENTS 3-RCS 1 PSR051 VT-3 Satisfactory None [ t 3-RCS-I-PSR073 VT-3 Satisfactory None 3-RCS-1 PSR24 VT-3 Satisfactory None 3-RCS-1 PSR25 VT-3 Satisfactory None i 3-RCS-I-PSR26 VT3 Satisfactory None j 3-RCS-I PSR$77 VT-3 Satisfactory None l 3-RCS-1 PSR578 VT-3 Satisfactory None 3-RCS-I-PSR579 VT-3 Satisfactory None 3-RCS-1 PSR67 VT-3 Satisfactory None 3-RCS-1-PSR69 VT-3 Satisfactory None 3-RCS-1-PSS11063 VT-3 Satisfactory None j 3-RCS-I-PSSil500 VT-3 Satisfactory None 3-RCS-1 PSSil501 VT-3 Repaired Tighten Loose Nuts f 3-RCS-I-PSSil505 VT-3 Satisfactory None 3-RCS 1-PSSil506 VT3 Satisfac6ory None 3-RCS-1 PSSil507 VT-3 Satisfactory None i 3-RCS-1-PSSil508 VT-3 Satisfactory None 3-RCS-1-PSSil543 VT-3 Satisfactory None 3-RCS-1-PSSil545 VT 3 Satisfactory None 3-RCS-1-PSST 074 VT-3 Satisfactory None 3-RCS-1-PSST 075 VT-3 Satisfactory None l 3-RCS-1-PSST 076 VT-3 Satisfactory None 3-RCS-1-PSST 800 VT-3 Satisfactory None 3-RCS 1-PSST 803 VT-3 Satisfactory None RilS i 3-RilS-1-PSST 010 VT-3 Satisfactory None 3-RilS-1-PSST 0ll VT-3 Satisfactory None 3-RilS-1-PSST 012 VT-3 Satisfactory None 3 RilS-4-PSS11014 VT-3 Satisfactory None 3-RilS-4-PSSII016 VT-3 Acceptable No Jam Nut On Upper Eyenuts 1 Report: rptNDEResultsSummary p,9,3g og 49 Sorted: Cet/ System /ReferencelD .- l
CATEGORY SYSTEM REFERENCE ID EXAMS DISPOSITION COMMENTS 3-RilS-4-PSS11018 VT-3 Acceptable til Marker At 1270, Cl Marked At 1484 - Reset Spring Can Setting 3-RilS-4-PSST 015 VT-3 Satisfactory None 3-RilS-4-PSST 019 VT-3 Satisfactory None 3-RilS-4-PSST 020 VT-3 Satisfactory None 3-RilS-4-PSST 021 VT-3 Acceptable Nuts At Area A&B Of Figure I Are Less Than Fully Engaged RSS 3-RSS-4-PSSill61^ VT-3 Acceptable Cold Load Design - 1309 3-RSS-4-PSST 160 VT-3 Satisfactory None 3-RSS-4-PSST 164 VT-3 Acceptable Jam Nut At Strut Appears To Be Backed Off Appx !/4 To 1/2 Turn. Attachment At Pipe is Insulated 3-RSS-4-PSST 416 VT-3 Satisfactory None SFC 3-SFC-3-PSR083 VT-3 Satisfactory None 3-SFC-3-PSR084 VT-3 Satisfactory None 3-SFC-3-PSR090 VT-3 Satisfactory None 4 Sill 3-Sill-1-PSR566 VT-3 Satisfactory None SIL 3-SIL-1-PSST 007 VT-3 Satisfactory None 3 SIL-l-PSST 025 VT-3 Satisfactory None 3-SIL-1-PSST 034 VT-3 Satisfactory None 3-SIL-l-PSST 036 VT-3 Satisfactory None SWP 3-SWP-4-PSR i l 8 VT-3 Satisfactory None 3-SWP-4-PSR120 VT-3 Satisfactory None 3-SWP-4-PSR121 VT-3 Satisfactory None 3-SWP-4-PSSill l3^ VT-3 Satisfactory None 3-SWP-4-PSSill l6^ VT-3 Satisfactory None 3-SWP-4 PSSilll9 VT-3 Satisfactory None 3-sWP-4-PSSill22^ VT-3 Satisfactory None Report; rptNDERecultsSummary Page 40 of 41 Sorted: Cat / System /ReferencelD
. - _. ~. _, _.. _. _. l 1 CATEGORY SYSTEM REFERENCE ID EXAMS DIF70SITION COMMENTS l 3-SWP-4-PSSTi l l^ VT-3 S tisfactory None 3 SWP-4 PSSTil7 VT-3 Satisfactory None 3-SWP-4-PSST 436 VT-3 Satisfactory None FSAR RPV RPV I!EAD CLADDING VT-3 Satisfactory None PLANT CHS CilS-12-FW-2 PT Satisfactory None CllS-35-2-SW-4 PT Acceptable None CilS-35-FW-13 PT Acceptable None CilS-503-FW-3 PT Satisfactory None FWA 3-FWA-PIB PT Satisfactory None RCS DISK PRESS. SYSTEM - A PT Satisfactory None DISK PRESS. SYSTEM - B PT Satisfactory None DISK PRESS. SYSTEM - D PT Satisfactory None RPV CANOPY SEAL WELD VT-1 Satisfactory None l d Report: tytNDEResultsSwanwy p,,,4g og 49 Sorted: Cat / System /ReferencelD
l i i 4.0 Procedures NDE Examinations Procedures This section describes the requirements which provide the basis for the various NDE Examination Procedures used during the Millstone 3 ISI. Included is a complete list of the procedures used for implementing inservice inspections. Ultrasonic Examination Procedures i With the exception of piping welds, Ultrasonic examinations for Inservice Inspection were performed in accordance with the requirements of ASME Section XI,1983 Edition, including i Addenda through Summer 1983. Piping welds were examined using a procedure developed by NU under the provisions of IWA 2240 of ASME XI. NU used ASME XI, Appendix VIII as a guide to develop the procedure including qualifying the procedure on flawed specimens. The procedure utilized 70 degree longitudinal mode for detection and sizing of service induced flaws. The procedure is applicable to carbon steel and austenetic stainless steel butt welds. Magnetic Particle Examination Procedures Magnetic particle examinations were performed in accordance with Article 7, ASME Section V. Liquid Penetrant Examination Procedures Liquid Penetrant examinations were performed in accordance with Article 6, ASME Section V. Visual Examination Procedures l Visual examinations were performed in accordance with Subarticle IWA-2210 of ASME Section XI. \\ Eddy Current Examination Procedures l Eddy Current examinations were performed in accordance with ASME V Article B. Pressure Tesis Pressure Tests examinations were performed in accordance with IWA-5000 of ASME Section XI 9
t I MILLSTONE UNIT 3 NDE PROCEDURES NIS 1 I NDE PROCEDURES Procedure No Procedure. Title t g Rev EN31063 System Pressure Tests 7 MIS AUT 15 Automated inside Surface UT Examination of Ferritic Vessels > 2"in Thickness 2 MIS-AUT 18 Automated Outside Surf ace UT Examination of Ferritic Vessels > 2" in Thickness 3 MIS-AUT-20 Automated UT Examination of Vessel-to-Nozzle inner Radius O NEU-ISI-115 Westinghouse Procedure for UT Examination of RPV Stude NEU-Isi-70 Westinghouse Procedure for MT Examination of RPV Studs NU-ET 2 Eddy Current Procedure Surface Probe Examination 4 NU-LP-1 Uguid Penetrant Procedure Color Contrast Solvent Removable 12 NU-LW-1 Manual UT Examination. Clad Carbon, Carbon and/or SS Butt Welds 3 NU-MP-1 Magnetic Particle Procedure Dry Particle Yoke Method 10 NU-UT-1 Ultrasonic Examination General Requirements 11 NU-UT 2 Ultrasonic Examination Austinetic and Dissimilar Piping Welds 11 NU UT 6 Ultrasonic Examination Procedure Reactor Coolant Pump Flywheels Millstone Unit 3 4 NU-UT 7 Ultrasonic Examination Vessel Welds 6 NU-VE1 Visual Examination Procedure (VT 1) 0 NU-VE 2 Visual Examination Procedure (VT-2) System Hydrostatic and Leakage Pressure Tests 0 NU-VE 3 Visual Examination Procedure (VT-3) 0 NU VE 4 Visual Examination Procedure - Reactor Vessel Interiors 0 NUSCO-AMD-013 Millstone Flywheel Eddy Current 0 l 4 l l 4 flePort: arptNDEProceduree Page 1 of 1
t h 5.0 Personnel and Equipment Summary t In this section is a list of personnel and their qualifications for those individuals involved in the examinations and tests identified on in this summary report. Also included is a list of equipment and consumable materials used in the conduct ofISI. i t L i I' I 10
MILLSTONE UNIT 3 PERSONNEL & EQUIPMENT
SUMMARY
NIS 1 NDE PERSONNEL Company.! Name ( UT ' PTi ;MTf VT-1 VT-2 VT-3 l ETn ABB AMDATA ABBUIT, JOHN H. I E H H II ABB AMDATA ELLIGIT, CRAIG I E H H II E ABB AMDATA HALL, SCUIT H II ABB AMDATA LASOYA,CAREY H H H H HL ABB AMDATA MASTER, HERCULES II H H ABB AMDATA MCDONALD, RANDALL 11 11 H H IIL ABB AMDATA McKAIO. MICHAEL W W W IU HI ABB AMDATA MURCH, WILLIAM I H H H H H ABB AMDATA NEWBOLD, STEVEN 1/IIL HI IU Ill W HI ABB AMDATA OLIVARES, MICHAEL 11 H H ABB AMDATA PENNANEN, ARTHUR H H H H H H ABB AMDATA POOLER, GERALD H H H H H ABB AMDATA ROSEBROOK, WILLIAM II H II U U H ABB AMDATA SCilANINK. DANIEL II II H H II ABB AMDATA SCHMALZ, SCOTT HL U U H H ABB AMDATA SHAW,CLAYTON H ABB AMDATA SMrril, KEN H H H H H ABB AMDATA SUCHAR, FLORIAN D U U U U ABB AMDATA SUMMERFORD, DANIEL U IIL II H ABB AMDATA U'REN, THOMAS II H H H II H ABB AMDATA WILLIAMS, STEPHEN H II I ABB AMDATA WINGFIELD, TIM U U H H H H MQS BLANKENSHIP, ROY MQS LUKO, ROBERT H H H H H 11 MQS SHERWIN, MICHAEL H H H H II U MQS SMirH, ALAN II U U II 11 H NORTHEAST UTILrrIES COLOPOULOS, RICHARD D H H NORTHEAST UTILrrIES DUPLANTIS, SCOTT Il 11 II H H H NORTHEAST LTTILrrIES ICKES TOM H H 11 NORTHEAST ITTILrrIES MACNEILL, DAVID E W W HI NORTHEAST UTILTTIES PFANNENSTIEL, RICHARD III HI W NORTHEAST UTILrrIES S!KORSKI STEVE E III W NORTIIEAST UTILTTIES WTITMER, ROBERT IH NORTHEAST Irr!LrrIES ZIEBER, RICHARD Ill HI III IU RUST ELLIS, J AMES II II II H H II RUST HECHT, JEFF III IH W Ill IH III RUST LINDELL, KENNETH IIL H H H II H RUST M ATYAS, J AMES II L H H II H RUST McCAUSLAND, DAVID IIL 11 II 11 RUST MOSTOWY, RAY II H II II 11 RUST PERRY, ROBERT UL H H RUST TINO, TONY I H D H 11 11 j SWRI ALEI ANDRO, JOSE II H H Il SWRI DELXI ADO, JESSE 11 U II SWRI DIAZ, HECTOR 11 II H SWRI G AINES, PRESTON 11 II 11 II SWRI HENZE, HAROLD I I I I SWRI M ARIN, SIMON H H H II Report: arptPersonnelEquipment Page 1 of 6
SWRI MATHENA LAVAR H H H H SWRI NIEMEYER, ROY III III M IH SWRI RIDDLES, RICH ARD H H II H SWRI TODD, STEVEN II II H H SWRI TURNER, PATRICK H H H H SWRI WARDWELL, JAMES U II II H TELEROBMICS BAGLEY, JOSEPH UI m IH TELEROBMICS CHIEKA, STAN D H H H H TELEROBMICS FRANKLIN, GREGORY II H H TELEROBMICS GEORGE, DAVIS H H H TELEROBMICS NILRATAN, PAUL IH HI HI TELEROBMICS RAMSEY, WAYNE H II H TELEROBOTICS ROBINSON, RAY H H H TELEROBMICS RUIZ, JIM U H H TELEROBOTICS SPINDLER, STEVE H H H TELEROBOTICS 3700 DEN, DAVE H H H WESDYNB ACKERMAN, HARRY I U H H H WESDYNB BEHANNA KENNETH H H H H H WESDYNB CASSET, ROBERT II E H 11 11 WESDYNB DELBUSSO, JAMES II H H 11 H WESDYNB HALLEY. WILLIAM H H H II E ULTRASONIC INSTRUMENTS Manufacturer: Serial No. Model < Commentsi Krautkrarner Branson 32810-3022 USK 7D Krautkramer Branson 32810-3023 USK 7D Krautkramer Branson 32810-3024 USK 7D Krautkramer Branson 32810M52 USK 7D Krautkramer Branson 32810-548 USK 7D Krautkramer Branson 32810-821 USK 7D Krautkramer Branson 32810-900 USK 7D Krautkramer Branson 32810-917 USK 7D Krautkramer Branson 32810-923 USK 7D Krautkramer Branson 32810-924 USK 7D Krautkramer Branson 32810-949 USK 7D Panametrics 91031004 Epoch 11 Panametrics 91035508 Epoch Il Sonic 04831E Mark Il SWRI Sonic 04832E Mark H SWRI Sonic 05325E Mark II SWRI Sonic 05326E Mark 11 SWRI Sonic 06208B 136 Ultrascope Westinghouse Sonic 07855B 136 Ultrascope Westinghouse Sonic 136-474F 136 Ultrascope Westinghouse Sonic 860K 136 Ultrascope SWRI SWRI 171120 Mark HA SWRI SWRI 171121 Mark HA SWRI SWRI 171122 Mark HA SW1tl SWRI 171123 Mark IIA SWRI SWRI 171124 Mark IIA SWRI Report: arptPoreonnelEquipnwnt Page 2 of 6
ULTRASONIC TRANSDUCERS Manufacturer; Serial No ; ' Type /Stylej C g W nts:: Harisonic 01156 HB-598-C Harisonic K1096 HDI 222 Herisonic K5215 HDI 4612 Harisonic K6272 HDIA614 Harisonic K9311 HDI 222-70L Harisonic K9312 HDLA612 70L Harisonic K9313 HDIA612-70L Harisonic K9317 HDIA614-70L Harisonic K9318 HDIA614-A-70L Harisonic K9320 HDL 4614-A 70L Harrisonic L2296 HDL Harrisonic L2297 HDL Harrisonic L2298 HDL Harrisonic L3048 HDL Harrisonic L3049 HDL Harrisonic L3050 HDL Harrisonic L3051 HDL Harrisonic L3052 HDL Harrisonic LJ135 HDL KB Aerotech 00269T ANN 2-2-2 KB Aerotsch 00841T ANN-2-2-4 KB Aerotech 01469 MSEB-4E KB Aerotech 24736 Gamma-MSWQC KB Aerotech 45117 Gamma-MSWQC KB Aerotech 57462-8870 083057462 KB Aerutech 57462-9684 Gamma KB Aerotech 83700 Gamma MSWQC KB Aerotech A26462 Gamma KB Acrotech A31369 Gammac KB Aerotech D05921 SWRI KB Aerutsch D05924 SWR 1 KB Aerotech F03122 Gamma KB Aerotech F15174 Gamma SST KB Acrotech F18229 Gamma KB Aerutech F21520 Gamma-HP KB Aermach G15620 Gamna KB Aerotech G15624 Gamma KB Acrotech H-5165 Gamma KB Aerotech J03269 Gamma SWS KB Aerotech J15817 Gamma KB Aerotech K11584 Gamma KB Aerotech K29262 Gamma KB Aerotech L18101 Gamme KB Aerotech M10131 Gamma KB Aerotech X500 SWRX Megasonics Al211 MST = Megasonica A1212 MST Panametrics 59324 D791RM j Sonatest 3262 SWit! l Sonatest 3263 SW1tl Sonatest 3264 SWRI Sonatest 3265 SWRI Report: arptPorsonneEquipment Pa8e 3 of 6
1 I Sonated 3266 SWRI Sonated STil41 SWRI Sonates STil44 SWRI Sonated STil47 SWRI Sonated STl!48 SWRI Sonates ST2697 SWRI SWRI 2213 SWRI SWRI 2505 SWRI l swr 2507 SwRI 3 SWRI 3391 SWR 1 SWRI 3423A SWRI SWRI 3771 SWRI SWRI 3971 SWRI 7 l SWRI 3973 SWR 1 j l SWRI 3988 SWRI SwRI 399: SWRI SWRI 4015 SWRI SWRI 4059 SWRI i SWRI 4060 SWRI SWRI 4072 SWRI ] SWRI 4077 SWRI SWRI 4171 SWRI i SWRI 4237 SWRI 7 j SWRI 4242 SWRI I SWRI 4245 SWRI J SWRI 4326 SWRI l SWRI 4330 SWRI SWRI 4334 SWRI t ] SWRI 4350 SWRI SWRI 4522 SWRI SWRI 4523 SWRI SWR 1 4525 SWRI SWRI 4526 SWRI q SWRI 4552 SWRI SWRI 4667 SWRI a 4 i l Repwt: wptPorsennelEquipment Fase 4 of 6
REFERENCE STANDARDS & CAL BLOCKS Descriptiony , Material Block /Std ID l 788648 I!W-2 Stainless 85-4122 Step Wedge Sisindens 93 4 841 Rompas Carbon 93-7228 Rompaa Carbon 93-7230 IlW Carbon 91-7234 Step Wedge Stainless 93-7322 Step Wedge Stainless 94-7426 Rompas Stainless 94-7428 Rompaa Stain!cas M3-UT 1 RPV Upper Shell Ferride M3-UT-2 RPV tower Shell Ferritic M3-Ur-21 Class 1 Piping Austenitic M3-Ur-26 Class 1 Piping Austenids M3-Ur-29 Flywheel Cal. Std. A533 GR. M3-UT-3 RPV Bottoin Head Ferritic M3-Ur-34 MSS Pipe Ferride M3-UT-35 MFW Piping Ferride M3-Ur-4 SG Primary Side Ferride j M3-Ur-41 MSIV Studs Ferritic M3-UT4 Flange Ligament Ferrids M3-Ur-8 SO Secondary Side Ferride Ur-LW-1 Generic bWave Ferride Ur-LW-10 Generic DWave Ferritic UT-LW-13 Generic LWave Austenitic UT-LW 15 Generic DWave Austenitic Ur-LW-2 Generic bWave Ferride Ur-LW4 Generic LWave Austenitic Ur-LW-7 Generic UWave Austenitic Ur-LW-9 Generic LWave Austenide MT PROBES Yolk SIN Manufacturer 4343 Parker 4344 Parker 4654 Parker l WO9880 Parker i EDDY CURRENT EQUIPMENT 1 Description ? S/N Manufacturer Model-Eddy Current Instrument 120 Zetec MIZ-20A Eddy Current Probe 195564 Zetec MIZ4 Eddy Current Standard ET-2A Nonheast Udlities Eddy Current Standard Z-1792 Zetec Report: arptPeroonnelEquipment Page 5 or 6 i
CONSUMABLES Description ? 9Batchi cTypej- < Mfr.::7 Comments Cleaner 952694 SKC-S Spotcheck Westinghouse I Cleaner 93F03K SKC-S Spotcheck Cleaner 93M04P SKC-S Spotcheck Developer 92J05K SKD-S2 Spoicheck Developer 94A02K SKD-S2 Spotcheck Magnetic Particle 93D040 1 Gray Magna0ux Magnetic Particle 93002P 14AM .Magna0ux Westinghouse Magnetic Particle 94F046K 14AM MagnaGux Westinghouse Magnetic Particle 95A030 1 Gray Magnailux Penetrant 93K0lP SKL-SI-Spotcheck Penetrant 94D17K SK14P Spotcheck q UT Couplant 092101 Sonotrace 40 Sonotrace UT Couplant 093104 Sonotrace 40 Sonotrace trr couplant 19520 Ultrage! II Ultrasound LTT Couplant 29420A Ultrage!II Ultrasound UT Couplant 93820 Ultrage!II Ultrasound LTT Couplant 93820N Ultragel II Ultrasound UT Couplant 94243 Sonotrace 40 Sonotrace SWRI GRAY CARDS Gray Card 8/N.. R&2001 R&3005 R &3007 s R &3012 R &3025 TEMPERATURE GAUGES serial No. - Manufacturer.; - Comments: 10017 Westinghouse 124624 Pacific 129625 Pacific 12 % 26 Pacific 129627 Pacific 129628 Pacific 129629 Pacific 129630 Pacific 129631 Pacific 129632 Pacific ) 129635 Pacific 208 Amprobe S%1tl 209 Amprobe SWRI 5112 6030145 Q A-5115 Report: arptPersonnelEquipment Page 6 or 6
i i j 6.0 Abstract of Corrective Measure Recommended and Taken Inservice inspection Reoairs/ Replacements t All defects noted during ISI with dimensions exceeding the acceptance criteria were identified for repair in accordance with NGP 3.13, " Inservice Inspection Unresolved Indication Reporting." 6.1 The defect removal was performed by NNECO in accordance with the appropriate NNECO procedure and Quality Assurance Requirements. All repairs implemented as a result ofISI is documented on form NIS-2 and are included in section 7.0. 6.2 Upon completion of the repair, the area or volume containing the defect was reexamined using the same examination method which was employed when the defect was detected. These reexams were performed by ISI personnel. l 4 11
7.0 Form NIS-2 Owner's Report for Repair or Replacements When repairs or replacements of pressure retaining components and their supports were required, they were performed in accordance with Millstone Work Control Procedure WC-3, ASME { Section XI Repair / Replacements. i NIS-2 data reports are sorted by ASME code class. These include replacements and repairs on i Code Class 1 and 2 piping and components conducted since the preceding summary report. All records for repairs and replacements required by IWA-6000 are maintained at the Millstone Nuclear Power Station. i d F 12
Form NIS OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 4/15/94 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: U3 Maintenance AWO Numbers Address: P. O. Box 128, Waterford CT M3-92-12942 A SYSTEM: RCS CODE CLASS: 1 5. Applicable Const. Code: ASME III Edition: 1977 Addenda: S79 Case Edition of: Section XI Utilized for work 1983,S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Components ID Name of 6 Nat'l Board Repair / ASME Number Manufacturer Mfrs. S/N_ AwNumber Replacement Stamped 3RCS*PCV455A CROSBY K72047 ,1=.,hT4.solenoic REPLACEMENT YES v1v s/n P-131 N96012-38-003 =c luo
- 0002 )
7. Description of work: Reolaced seat. oIu)g and solenoid due to seat leakage 6 mrir's..... a)385-603-2 b)189-111-1 8. Test Conducted: Hydrostatic ] Pneumatic Normal Operating Pressur'E [Othei E,,,*ewo m3-92-2055s CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI. 4" 20 -W Signed: Mat -~ Date: CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period 90/26/9210 5/12/94 and state that to the best of my knowledge and belief, the owner has performed examinations and j has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the mspector nor his employer makes any warranty, expmssed or implied, concerning the examinations and corrective measures described i:2 the Owr.er's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. InsIwctor's Signature: ELIZABETH YORK Commissions: CT 1137 Date: 12 MAY 1994
i l l Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 1/31/94 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit D
- 3. Work Performed By: Generation Construction AWO Numbers Address:
P. O. Box 128. Waterford CT M3-93-03913' M3-93-03914 M3-93-03924 M3-93-03925 M 3-93-05585
- 4. SYSTEM:
RCS CODE CLASS: 1
- 5. Applicable Const. Code:
ASME Ill. Edition: 1986 Addenda: 16 Code Edition of Section XI Utilized for work 1983.583 Code Case N249-10
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped 3RCSISUP4-19 Paul Monroe 14310-161 N/A Modify No 3RCSISUP4-45 Paul Monroe 14310-187 N/A Modify No 3RCSISUP4-43 Paul Monroe 14310-185 N/A Modify No 3RCSISUP4-39 Paul Monroe 14310-181 N/A Modify No 3RCSISUP4-25 Paul Monroe 14310-167 N/A Modify No
- 7. Description of work: Install Functional Testine liardware For ifydraulic Snubbers to Test inolace.
- 8. Test Conducted:
Ilydrostatic < > Pneumatic < > Normal Operating Pressure < > Other < X > VT CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of ASME Code, Section XI I - 3 ) ~ ') h Signed: bILod Date: CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and e played by llartford Steam Boiler Insurance and Inspection during the period T2f.92 to 8 7.9, and state that to the best of my knowledge and belief, the owner has pedormed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Commissions: dr//M Inspector's Signature: 2h// Date: 9
= i i Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS i i l
- 1. OWNER:
Northeast Utilities Service Co. Date: 1/31/94 f P. O. Box 128. Waterford CT r
- 2. PLANT:
Millstone Nuclear Power Station Unit D
- 3. Work Performed By: Generation Construction AWO Numbers l
Address: P. O. Box 128. Waterford CT M3-93-05135 M3-93-05134 i M 3-93-05090 l
- 4. SYSTEM:
Sjt CODE CLASS: 1
- 5. Applicable Const. Code:
ASME lil. Edition: 1911 Addenda:S73 l 2 Code Edition of Section XI Utilized for work 1983.S83 t l
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
j Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped i l 3SILIPSSP-459 FIT GRINNEL 3507 N/A Replacement No i 3SILIPSSP-414 ITT GRINNEL 16548 N/A Replacement No 3SILIPSSP-1051 ITF GRINNEL 29354 N/A Replacement No j
- 7. Description of work: Snubbers replaced a
j
- 8. Test Conducted:
j Hydrostatic < > Pneumatic < > Normal Operating Pressure < > Other < X > VT CERTIFICATE OF COMPLI ANCE We certify that the statements made in the report are correct and this repair conforms to the rules of j-ASME Code, Section XI Signed: I t<d Date: /OI~ N CERTIFICATE OF INSERVICE INSPECTION i 1 j I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler l lasurance and Inspection during the period RS.pf to 2.f.k, and state that to the best of my i knowledge and belief, the owner has performeil examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall he liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Sig nature: Commissions: N//r, i Date: d'E.Rf 4
j O 1 Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS i
- 1. OWNER:
Nor*ka-d UeMa= Service Co. Date: 1/31/94 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Una C j
- 3. Work Performed By: Genernhon Construchon AWO Numbers Address:
P. O. Box 128. Waterford CT M3-93-05138 M3-93-05082
- 4. SYSTEM:
RCS CODE CLASS: 1
- 5. Applicable Const. Code:
ASME IIL Edition: 1221 Addenda:S73 4 Code Edition of Sechon XI Utilized for work 1983.S83
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME i ID Number Manufacture S/N. No. Replacement Stamped N/A Replacement No 3RCSIPSSP-914 ITT GRINNEL 20519 2 l 3RCSIPSSP-1068 ITT GRINNEL 20996 N/A Replacement No
- 7. Description of work: Snubbers reolaced 4
1
- 8. Test Conducted:
1 Hydrostatic < > Pneumatic < > Normal Operating Pressure < > Other < X > VT l 1 ( l CERTIFICATE OF COMPLIANCE i 'a We certify that the statements made in the report are correct and this Islag conforms to the rules of j ASME Code, Section XI e Signed: dM% / Date: / 31-9 9 1 f j CERTIFICATE OF INSERVICE INSPECTION J I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by llartford Steam Boiler 4 Insurance and Inspection during the periodEf.ff to ff.M, and state that to the best of my l knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. 4 Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal iqiury, property damage, or loss of any kind arising from or connected with this inspection. inspector's Signature: Commissions: 22fjjyy
- 2.If,//,/
I Date: 4 + e-~. m
_~ _.. _ __.. _ __... _ __ _ _ i.. j j Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 12/14/93 1 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit #2 1 j
- 3. Work Performed By: Maintenance AWO Numbers I
q Address: P. O. Box 128. Waterford CT M3-934)9403 i
- 4. SYSTEM:
RCji CODE CLASS: 1 2 i
- 5. Applicable Const. Code:
ASME Ill. Edition: 191[ Addenda: E72 .l Code Edition of Section XI Utilized for work 1983.S83 j
- 6. IDENTIFICA' lion OF COMPONENTS REPAIRED OR REPLACED:
Components Name of M frs. Nat'l Board Repair / ASME ]j ID Number Manufacture S/N. No. Replacement Stamnavi 3RCS*SV8010A Crosby 0103 N/A Replacement Yes 4 1
- 7. Description of work: Reolace Valve with Snare S/N 0101: and snare had nozzle. diisk inert. and i
bellows. t
- 8. Test Conducted:
j Hydrostatic < > Pneumatic < > Normal Operating Pressure <X> Other < > CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI l Signed: 44, Date: /8*U"N i i j CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid cogs Pressure Vessel Inspectors and the State of - gi sped by the National Board of Boiler and .__ and employed by Hartford Steam Boiler Insurance and Inspection during the period 9/.fMs to v/sVr/, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. l Inspector's Signature: M // d.'/ M / 4._. Commissions: A,/ 4 ### Date: ///.2 /M 1 m
(: Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 1/14/94 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit #2 AWO Numbers
- 3. Work Performed By: Maintenance Address:
P. O. Box 128. Waterford CT M3-93-17731 CODE CLASS: 1
- 4. SYSTEM:
RCE 583 8
- 5. Applicable Const. Cc::e:
ASME Ill. Edition: 1983 Addenda: Code Edition of Section XI Utilized for work._983.S83 1 I i.
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped N/A Replacement No 3RCS*PIC Westinchouse
- 7. Description of work: Replaced Seal Cartridee Hold Down Bolts P HT. Code M26364)
- 8. Test Conducted:
actual installation performed via awo M3-93-05875 vdr<1 > Other <X:> Hydrostatic < > Pneumatic < > Normal Oneratine Pressp 1 I CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renair / replacement conforms to niles of ASME Code, Section XI i Signed: 9kM m.I Date: l-t 49@ 1 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and 08/14/9410 14 9gloyed by Hartford Steam Boiler d m Pressure Vessel Inspectors and the State of Connecticut , and state that to the best of my Insurance and Inspection during the period knowledge and belief, the owner has performed examinations and has taken corrective measures ') described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any persona! injury, property damage, or loss of any kin arising from or connected with this inspection. Commissions: CT 1137 NB 9384 Inspector's Signature: E YORK Date: APRIL 11, 1994 i 1
l i 3__ h ~) t' Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS I j~
- 1. OWNER:
Northeast Utdaties Service Co. Date: 12/12/.21 t P. O. Box 128. Waterford Cr I
- 2. PLANT:
Mdistone Nuclear Power Station Unitil
- 3. Work Perfonned By: Westinghouse AWO Numbers Address:
P. O. Box 128. Waterford CT M3-9318061 & M3-93-18504 l i l
- 4. SYSTEM:
RCS CODE CLASS: 1
- 5. Applicable Const. Code:
ASME Ill. Edition: 1221 Addenda: 321 I l Case Edition of Section XI Utilized for work 1983.583 l
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
t f l Components Name of Mfrs. Nat'l Board Repair / ASME f ID Numher Manufacture S/N. Serial Replacement Stamped j 3RCS*SGIA Westinghouse NEGT1776 W13584 Repair Yes I 3RCS*SGIC Westinghouse NEGT1778 W15216 Repair Yes l i J.
- 7. Description of work: Steam Generator Tubes Plugged f
i l
- 8. Test Conducted:
Hydrostatic < > Pneumatic < > Normal Operating Pressure < > Other < > l CERTIFICATE OF COMPLIANCE 4 We certify that the statements made in the report are correct and this apag confonns to the rules of ] ASME Code, Section XI 1 Signed: fac. !r Date: /' E 6 - 7 h j J CERTIFICATE OF INSERVICE INSPECTION i 1 I, the undersigned, holding a valid commission iN by the National Board of Boiler and Pressure Vessel laspectors and the State of Connecticut ano employed by Hartford Steam Boiler '--- => and Inspection during the period 9//f to /1Ff/, and state that to the best of my 1 knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. 3-Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal igiury, property damage, or loss of any ki arising from or connected with this inspection. Inspector's Signature: Commissions: A,-MS ] ^'&)%W ~ 9,,,.,/,jpg
_ _ _ _. _. ~...... _ _ _ _. _ ~ __ -._ _. ___ _ _ \\ I i 1 j Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS i 4 I i
- 1. OWNER:
Nor+b-* Utilities service Co. Date: 4/22/94 I, P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit D ) i i
- 3. Work Performed By: Maintenanc, AWO Numbers l
4 Address: P. O. Box 128. Waterford CT M3-93-23498 1
- 4. SYSTEM:
Bra CODE CI ASS: 1 l t l j
- 5. Applicable Const. Code:
ASMEIII. Edition: 1911 Addenda: $21 f' Case Edition of Section XI Utilized for work 1983.S83 2
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
1 Components Name of Mfrs. S/N Nat'l Board Repair / ASME l ID Number Manufacture Number Replacement Stamped 3RCS*PI A Westinghouse 8-1162E93G03 87 Replacement YES 7, Description of work: Renlace 1 Housine Can Screws par t # 4936A90H2O (mpen 387-116-1) f l S/N's 10116, 10117, 10118, 10119, 10120,10131, 10132,S10133. r i 'd. Test Conducted: )l Hydrostatic < > Pneumatic < > Normal Operating Pressure < > Other < X > VT { t i CERTIFICATE OF COMPLIANCE k [ We certify that the statements made in the report are correct and this replacement conforms to the rules of j ASME Code, Section XI 5 Signed: Ab-Date: b 9 - M' t l l. CERTIFICATE OF INSERVICE INSPECTION f I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and l + i Inspection during the period '#dVB3 oN, and state that to the best of my knowledge and belief, the l t owner has performed examinations and has taken corrective measures described in this owner's report in i accordance with the requirements of ASME Code, Section XI. 1 By signing this certificate neither the inspector nor his employer makes any warranty, expressed or l implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any mannar for any personal injury, property damage, j or loss of any kind arising from or connected with this ' tion. l ELIZABETH YORK [ Commissions.CT 1137 Inspector's Signature: / Date: 13 MAY 1994 f ~ - -, ---r -,c-- -r--- m r m---
I ra '+ 1 Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 11/23/93 P. O. Box 128. Waterford Cr i
- 2. PLANT:
Millstone Nuclear Power Station Unit gj,
- 3. Work Performed By: Maintenance AWO Numbers Address:
P. O. Box 128. Waterford Cr M3 93-23499
- 4. SYSTEM:
E.C1 CODE CLASS: 1 ,L921 Addenda: 314
- 5. Applicable Const. Code:
ASME III. Edition: 9 Case Edition of Section XI Utilized for work 1983.S83 2
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. S/N Nat'l Board Repair / ASME ID Number Manufacture Number Replacement Stamped [ I 3RCS*PID Westinehouse 7-1162E93G03 86 Replacement YES
- 2
- 7. Description of work: Replace Seal Housinc Can Screwspar t # 4936A90H2O (mpsn387-116-1)*
j S/N's 10127, 10128, 10129, 10130, 10130, 10134, 10138, 10141, S 10142. j
- 8. Test Conducted:
i Hydrostatic < > Pneumatic < > Normal Operating Pressure < > Other < X > VT i j CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI Signed:
- II4v, Date: f-f' 4
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure l Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period 9/EEVE3 o 10/ES/33, and state that to the best of my knowledge and belief, the t owner has performed examinations and has taken corrective measures described in this owner's report in l accordance with the requirements of ASME Code, Section XI. l By signing this certificate neither the inspector nor his employer makes any warranty, expressed or l implied, concerning the examinations and corrective measures described in the Owmer's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage. l or loss of any kind arising from or connected with this inspection. l Inspector's Signature:ELIZMETH YtFK [ Commissions: CT 1137 r-Date: 13 MAY 1994 4 4 t i i f
Form NIS-2 OWNERS REPORT FOR REPAIRS OR RErLACEMENTS i 1. OWNER: Nonheast Utilities Service Co. Date: 5/2/94 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Unit 3 Maintenance AWO Numbers Address: P. O. Box 128, Waterford CT MP3-93-23995 4. SYSTEM: CHS/3304A CODE CLASS: 1 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Case Edition of: Section XI Utilized for work 1983,S83 6. IDENTIFICATION OF COhU)ONENTS REPAIRED OR REPLACED: Components ID Name of Nat'l Board Repair / ASME j Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3CHS-150-689-1 N/A N/A N/A REPAIR NO 7. Description of work: Increase the leneth of the ninine by installing a 2" spacer to facilitate t installation of a new RCP. 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure X Other CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair / replacement (circle one) conforms to the rules of ASME Code, Section XI. b I"9 Signed: nab Date: CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period /q4//.f to N/4df, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, i Section XI. By signing this certificate neither the mspector nor his employer makes any warranty, expiessed or implied, concerning the exammations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. arI7#:r Commissions: 8-r#77 Inspector's Signature: Ar Date: 6/9/93
Form NIS-2 OWNERL..EPORT FOR REPAIRS OR Rm.'LACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 4/15/94 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 t 3. Work Performed By: U3 Maintenance AWO Numbers Address: P. O. Box 128, Waterford CT M3-93-24058 i 4. SYSTEM: CHS CODE CLASS: 1 i 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Case Edition of: Section XI Utilized for work 1983, S83 i 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED-t Components ID Name of Nat'l Board Repair / j ASME Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3CHS-150-686-1 Stone & Webster NA NA Repair NO i 7. Description of work: Modified CHS Pipine in order to install new numo 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure X Other CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI. Signed: lar Date:
- f. - 8
- I 4-CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Insptors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during t ApMff to h/off, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken colrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer mskes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Ower's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: n/ //37 Jor,[da Commissions: Or#T1 Date: (r/E8V'
l l Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- l. OWNER:
Nor*6e Utilities Service Co. Date: 12/15/93 f P. O. Box 128. Waterford CT j i
- 2. PLANT:
Mdistone Nuclear Power Station Unit n l
- 3. WoA Performed By: Mamtenance AWO Numbers Address:
P. O. Box 128. Waterford CT M3-93-250.31 1 l
- 4. SYSTEM:
RCJ CODE CLASS: 1
- 5. Applicable Coast. Code:
ASME III. Edition: 1224 Addenda: 321 Code Edition of Section XI Utilized for work 1983.S83
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME l ID Number Manufacture S/N. No. Replacement Stamped 3RCS*AV8037C Copes Vulcan 7620 1975 Replace Yes i
- 7. Description of work: Replace Valve Stem and Pluc- 04/gp/
j y, g.f r
- 8. Test Conducted:
Hydrostatic < > Pneumatic < > Normal Operating Pressure <X> Other < > i O csariric^rs os cour'i^xcs We certify that the statements made in the report are correct and this renlacement confonns to the rules of ASME Code, Section XI Signed: 44 wb Date: 17 - I b - 9 ~3 7 l CERTIFICATE OF INSERVICE INSPECTION l t 1
- 1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler r
Insurance and Inspection during the period /4/e/M toJ/1/95, and state that to the best of my l knowledge and belief, the owner has performed examinatRms and has taken corrective measures j described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal igiury, property damage, or loss of ind arising from or connected with this inspection. j laspector's Signature: Commissions: //f&/ h/J[ O ~
- --~ i 3 Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 3-21-95 P. O. Box 128. Waterford CT f 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Numbers Address: P. O. Box 128, Waterf ord CT M3-94-00306 4. SYSTEM: Reactor Coolant CODE CLASS: 1 5. App. Const. Code: ASME III Edition: 1971 Addenda: W72 Code Case: N/A Code Edition of: Section XI Utilized for work 1983.S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3RCS'SV8010B Northeast Utihties N56964-07-60 N/A Replacement N/A l [ 7. Description of work: Replace valve 3RCS*SV8010B 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure Other ( g CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conforms to the rules of ASME Code, Section XI. b ~b-78 Signed: A Date: CERTIFICATE OF INSERVICE INSPECTION Inspectors and the State ofg- -- g glid commission issued by the National Board of Boiler an 1, the undersigne d .2 and employed by Hartford Steam Boiler Insurance and Inspection during the period
- /w/r#to 7/'rMes' and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Mm//d ML-Commissions: WWP# Date: 9MF/rd* i I
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Nonheast Utilities Service Co. Date: 3-21-95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Numbers Address: P. O. Box 128, Waterford CT M3-94-00351 4. SYSTEM: Reactor Coolant CODE CLASS: 1 5. App, Const. Code: ASME III Edition: 1971 Addenda: W72 Code Case: N/A Code Edition of: Section XI Utilized for work 1983,S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3RCS *SV801DWC-Northeast Utilities N56964-7-103 N/A Replacement N/A <2' -4,/ 7. Description of work: Replace valve 3RCS*SV8010C 8. Test Conducted: j,, e p Hydrostatic Pneumatic Normal Operating Pressure Other g pop /co7-CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this trplacement conforms to the rules of ASME Code, Section XI. Signed: 40 Date: 7 /CN CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors andjhe State of Connecticut and employed by liartford Steam Boiler Insurance and Inspection during the period T Zf f5to a f 95, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissions: f#T7 Date: 7 I
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 6/30/95 j P. O. Box 128. Waterford CT t 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance AWO Numbers M3 94 04542 4. SYSTEM: RCS CODE CLASS: 1 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 l r Code Edition of-Section XI Utilized for work 83 S 83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: l Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3RCS*V107' Westinghouse 10000CS88000 N/A Replacement Yes OA000s740007 7. Description of work: Replace Studs and Nuts for Valve 3RCS*V107 8. Test Conducted: I Normal Operating Pressure ] Other Ilydrostatic Pneumatic X VT CERTIFICATE OF COMPLIANCE t We certify that the statements made in the repon are correct and this replacement conforms to the f rules of ASME Code, Section XI. i Signed: - 4 Date: dS'7&7[ CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel ins ectors and the State of Connecticut and employed by Hanford Stem oiler Insurance and hopection during the period n Tsu 6//?$r, and state that to the best of my knowledge and belief, the owner has performed examinations and las taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. i By signing this certificate neither the inspector ner his emp!c>n makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissions: [d W Psr / f/985~ \\ Date:
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 8-9-95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Numbers Address: P. O. Box 128, Waterford CT M3-94-12331 4. SYSTEM: RCS CODE CLASS: 1 5. App. Const. Code: ASME III Edition: 1977 Addenda: S79 Code Case: N/A Code Edition of: ASME XI Utilized for work 1983 S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3RCS
- PCV456 Crosby 72046-00-0001 6731 Replaced Yes 3 RCS
- PCV456 Garrett P-131 N/A Replacement Yes 7.
Description of work: Replace Valve 3RCS*PCV456 8. Test Conducted: Ilydrostatic Pneumatic Normal Operating Pressure x Other CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI. Signed: Date: 8 9 ~)< -- v CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and th S te of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period to y '~a~nd state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector ' nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising frem or connected with this impection. Inspector's Signature: Commissions: 4M7 Date:[/d/95 7 s
} Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS I
- 1. OWNER:
Northeast Utilities Service Co. Date: 6/28/95 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit #J.
- 3. Work Performed By: Maintenance AWO Numbers Address:
P. O. Box 128. Waterford CT M3-94-16977
- 4. SYSTEM:
RCS CODE CLASS: 1
- 5. Applicable Const. Code:
ASME Ill. Edition:1222 Addenda: 322 Case Edition of Section XI Utilized for work 1983.S85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped 3RCS* PORVSP CROSBY P 131 N/A Replacement Yes 3
- 7. Description of work: Snare PORV was overhauled and the plug reauired reolacement due to steam cutting. S/N of reolacement nlug-N96012-56-010,1 j
- 8. Test Conducted:
Hydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < > CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement confonas to the rules of ASME Code, Section XI Date: [ / c2 N 7 Signed: r j y-e CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance j and Inspctien tring 'h: p-icd,$,fd/ o 4,dsff, and si:t: th:t to the b:st Of my 1:nowkdge nd l t belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any ki d ing from or connected with this inspection. Commissions: 6#1,9 j Inspector's Signature: [ Date: NM ' s'
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 3-21-95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Nonheast Utilities AWO Numbers Address: P. O. Box 128, Waterford CT M3-94-19332 4. SYSTEM: Reactor Coolant CODE CLASS: 1 5. App. Const. Code: ASME III Edition: 1971 Addenda: W72 Code Case: N/A Code Edition of: Section XI ~ Utilized for work 1983,S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3RCS*SV8010A Northeast Utilities N56964-07-59 N/A Replacement N/A 7. Description of work: Replace valve 3RCS*SV8010A 8. Test Conducted: h h__ 7 liydrostatic Pneumatic Normal Operating Pressure Other ( CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conforms to the rules of ASME Code, Section XI. b'3*' Signed: 64 Date: CERTIFICATE OF INSERVICE INSPECTION 1, the undersignedgldpjjgalid commission issued by the National Board of Boiler and Pressure Vessel Ins. ctors and the State of m nwi and employed by Hartford Steam Boiler Insurance and Inspection during the period 41/ffto 2//Izt4 and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: d* N d. 7//INw Commissions: g/ 7WW_ Date: fddps
I l Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 5/31/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: MES AWO Numbers i Address: P. O. Box 128, Waterford CT MP-95-00537 4. SYSTEM: Feedwater CODE CLASS: 1 5. hpplicable Const. Code: ANSI B31.1 Edition: 1971 Addenda: S1973 Code Edition of: ASME XI Utilized for work 83S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Numbers Manufacturer Mfrs. S/N. Number Replacement Stamped 3FWSIPSSP.0429 ITT Grinell 14679 N/A Replace No 7. Description of Work Replaced Load Pin damaged during removal.
- 8.
Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure Other X Functional & Visual CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this modification conforms to the rules of ASME Code ction XI. 5'bI!9[ Signed: G3 Date: V M* N* V-N CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and tp/F, and state that to the best of my knowledge and belief the owner ha to /// taken corrective measures described in this owner's repon in accordance with the requirements of ASME Code, Section XI. By signing this cenificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal iniury, propeny damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissions: d-#P7 / L Date: b
@t Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 5/31/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: MES AWO Numbers Address: P. O. Box 128. Waterford CT MP 00549 4. SYSTEM: Reactor Coolant CODE CLASS: 1 5. Applicable Const. Code: ANSI B31.1 Edition: 1971 Addenda: S1973 Code Edition of: ASME XI Utilized for work 83S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Numbers Manufacturer Mfrs. S/N. Number Replacement Stamped Old: 3RCSIPSSP.0105 ITT Grinell 7740 N/A Replace No New: Same Same 15102 Same Same Same 7. Description of Work Snubber S/N 7740 Failed Functional Test. was reolaced by S/N 15102.* 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure Other X Functional & Visual
- Ne 72-28-oov-24 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this modification conforms to the rules of ASME Cod ion XI.
Signed: Date: $ 31 4[ CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period to 4//95, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: M P/ Commissions: 8r//:r7 Date: f///93
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 7-18-95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Numbers Address: P. O. Box 128, Waterford CT M3-95-01552 4. SYSTEM: RCS CODE CLASS: 1 5. App. Const. Code: ASME HI Edition: 1971 Addenda: S73 Code Case: N/A Code Edition of: ASME XI Utilized for work 1983 S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3RCS*RV1 Combustion Eng 7272 22003 Modification N/A 7. Description of work: Drill and tapped bottom of reactor vessel for LPM system 8. Test Conducted: Ilydrostatic Pneumatic Normal Operating Pressure Other N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI. s Signed: ) Date: M\\O v CERTIFICATE OF INSERVICE INSPECTION valid commission issued by the National Board of Boiler and Pressure Vessel I, the undersignedgig5d employed by liartford Steam Boiler Insurance and Inspection during Inspectors and the State of u m g?pBf to 7/Wh<and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector r.or Ms eployer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature:
- // d M//w Commissions: mow 97 Date: MM/M
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS.:p%g 1. OWNER: Northeast Utilities Service Co. Date: 5/31/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: MES AWO Numbers Address: P. O. Box 128, Waterford CT MP-95-02155 4. SYSTEM: S/G Blowdown CODE CLASS: 1 5. pplicable Const. Code: ANSI B31.1 Edition: 1971 Addenda: S1973 Code Edition of: ASME XI Utilized for work 83S83 6. IDENTIFICATION OF COMPONENTS REPA1 RED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Numbers Manufacturer Mfrs. S/N. Number Replacement Stamped Old: 3BDGIPSSP.(M61 ITT Grinell 17051 N/A Replace No New: Same Same 12868 Same Same Same -d-7. Description of Work Replaced Snubber S/N 17051 with S/N 12868 based on good engineering. iudgement 8. Test Conducted: Ilydrostatic Pneumatic Normal Operating Pressure Other X Functional & Visual CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this modification conforms to the niles of ASME C Section XI. Date: 3/ 9 [ Signed:
- cy,.,y,5 /- $ ?- 2 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period to/ h ff and state that to the best of my knowledge and belief, the owner has performed examinations and has taken correftfve neasures described in this owner's report in accordance with the requirements of ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. h//7f Inspector's Signature: M Commissions: Date: / % /fhf c/
> y! Form NIS-2 OWNERS RcPORT FOR REPAIRS OR REPLACEMENTS pZofZ l 1. OWNER: Northenct Utilities Service Co. Date: 5/31/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: MES AWO Numbers Address: P. O. Box 128, Waterford CT MP-95-02155 4. SYSTEM: S/O Blowdown CODE CLASS: 1 5. Applicable Consl. Code: ANSI B31.1 Edition: 1971 Addenda: S1973 Code Edition of: ASME XI Utilized for work 83S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME [ j Components ID Numbers Manufacturer Mfrs. S/N. Number Replacement Stamped i 3BDG1PSSP.0461 ITT Grmc41 12868 N/A Replace No 7. Description of Work Replace Load Stud damaoed during removal. 4 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure Other X Functional & Visual 1 CERTIFICATE OF COMPLIANCE i We certify that the statements made in the report are correct and this modification conforms to the rules of ASME Code, Section XI. Signed: - w Date: X/3/ f4 m CERT!FICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hanford Steam Boiler Insurance and Inspection during the period __ to / LA, and state that to the best of my knowledge and belief, the owner has performed exammations and has taken corrgp?e measures described in this owner's repon in accordance with the requirements of ASME Code, Section XI. By signing this cenificate neither the mspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Repon. Funhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, propeny damage, or loss of any kind arising from i or connected with this inspection. Inspector's Signature: y/ Commissions: M T9 Date: /Iw /#S u
Form NIS-2 OWNERS RtPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 5/31/95 gy( P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: MES AWO Numbers Address: P. O. Box 128, Waterford CT MP 02 llo L 4. SYSTEM: Low Pressure CODE CLASS: 1 Safety Injection 5. Applicable Const. Code: ANSI B31.1 Edition: 1971 Addenda: S1973 Code Edition of: ASME XI Utilized for work 83S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Numbers Manufacturer Mfrs. S/N. Number Replacement Stamped 3SILIPSSP.0470 ITT Grinell 26271 N/A Replace No 7. Description of Work Replace Load Stud damaged during removal. 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure Other X Functional & Visual CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this modincation conforms to the rules of ASME C ction XI. Signed: C~c' Date: .h CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State of Connecticut and employed by Hanford Steam Boiler Insurance and Inspection during the period to y//f, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's repon in accordance with the requirements of ASME Code, Section XI. l By signing this cenificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, propeny damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissions: May Date: g/2d_5"
Form NIS-2 OWNERS hcPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 5-15-95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Westinghouse AWO Numbers Address: P.O. Box 158 M3 95 02583 Madison, Penn 15663 1 4. SYSTEM: RCS CODE CLASS: 1 5. Applicable Const Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 S 83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: } Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3RCS*SGIB Westinghouse NEGT 1775 W13583 Replacement Yes 4 7. Description of work: Steam Generator plugs are currently Inconel 600 material. Inconel 690 olugs are preferred and will be installed in place of current plugs. 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure Other % none i 4 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reolacement conforms to the rules of ASME Code, Section XI. 4 Signed: Ellen Budnik (N/1 - f// Date: 6NK ./ / CERTIFICATE OF INSERVICE INSPECTION I, the undersigned hpin a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of rr.g=:#Id employed by Hartford Steam Boiler Insurance and In a / 4 e /gsto W.tand state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: M.u,#g.V/idL. Commissions: dy/.a 4/ p.y Date:4/JP//p.:s"
Form NIS-2 OWNERS hePORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 5-15-95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Westinghouse AWO Numbers Address: P.O. Box 158 M3 95 02591 Madison, Penn 15663 4. SYSTEM: RCS CODE CLASS: 1 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 S 83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3RCS*SGID Westinghouse NEGT 1777 WI5215 Replacement Yes 7. Description of work: Steam GeneIagor olugs are currently Inconel 600 material. Inconel 690 piggs are oreferred and will be installed in olace of current plugs. 8. Test Conducted: Hydrostatic Pneumatic ] Normal Operating Pressure ] OtherT none CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reolacement conforms to die rules of ASME Code, Section XI. 4 Signed: Ellen Budnik//////MdM(/#l b Date: 524 9T s j-CERTIFICATE OF INSERVICE INSPECTION I, the undersigned Inspectors and the State of yojdg=u:a valid commission issued by 6e National Board of Boiler and Pres and employed by Hartford Steam Boiler Insurance and Inspection during the period a x. J///M to 4/0/ /ncand state that to the best of my knowledge and belie?, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: A//zf. 'Mf//L., Commissions: q/.WPE Date: 4/.3//78 ~
. = -. Form NIS-2 OWNERS RtPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 7/19/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 i 3. Work Performed By: Maintenance AWO Numbers Address: P. O. Box 128, Waterford CT M3 95 08694,09023 4. SYSTEM: 3304A CODE CLASS: 1 5. Applicable Const. Code: ASME III Edition: 1974 Addenda: W75 Code Edition of: Section XI Utilized for work 83, W85 Addenda 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3CHS*MV8507A Westinghouse See Below W26521 Modification Yes 7. Description of work: MFO S/N 03003GM92FBB00000W750001 A Pressure relievine hole was drilled in the valve disc (downstream side) to vent the pressure in the valve bonnet to the downstream side of the valve. 8. Test Conducted: Hydrostatic { Pneumatic Normal Operating Pressure Other ] CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this modification rules of ASME Code, Section XI. Signed: O.b'l.Auvb Date: - 7,-2 O $ b9T f g ~ CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inypectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period
- V4#/9f to S//445, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissions: h#T7 7,d5 Date:
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS I. OWNER: Northeast Utilities Service Co. Date: 7/24/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance AWO Numbers Address: P. O. Box 128, Waterford CT M3 95 0869 4. SYSTEM: _3304A CODE CLASS: 1 5. Applicable Const. Code: ASME III Edition: 1974 Addenda: W75 Code Edition of: Section XI Utilized for work W 85 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3CHS*mV8507B Westinghouse See Below W26522 Modification Yes 7. Description of work: MFR S/N 03003GM92FBB00000W750002 A pressure relieving hole was drilled in the valve disc (downstream side) to vent the pressure in hte bonnet to the downstream side of the valve. 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure X Other CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this modification conforms to the rules of ASME Code, Section XI. i g Signed: k /4t e /_ __7 Z6-?[ 'T Date: CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel I ectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period to g4/f:(, and state that to the best of my knowledge and belief, the owner has performed examinations and as taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. inspector's Signature: / Commissions: [N.r7 ~,e 4 g 4%'
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 7-14-95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Numbers Address: P. O. Box 128, Waterford CT M3-95-08990 4. SYSTEM: RCS CODE CLASS: one 5. App. Const. Code: ASME III Edition: 71 Addenda: S73 Code Case: N/A Code Edition of: ASME XI Utilized for work 83 S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3 RCS
- PCV456 N/A N/A N/A Replacement N/A 7.
Description of work: Replace nuts and studs for valve 3RCS*PCV456. Pressure test was performed under AWO M3-94-12331. 8. Test Conducted: Hydrostatic l Pneumatic l Normal Operating Pressure x l Other xl V r g CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reolacement conforms to the rules of ASME Code, Section XI, 7'2 b 9E Signed: A O ~ Date: QJ CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel In rs and )t te, State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period to JMPr, and state that to the best of my knowledge and belief, the owner has performed examinations and aken co'rrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissionh#1~/ Date: [ N 1
Form NIS-2 OWNERS RtPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 7/18/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance AWO Numbers Address: P. O. Box 128, Waterford CT M3 9510237 4. SYSTEM: RCS CODE CLASS: 1 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: _ Section XI Utilized for work 83 S 83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3RCS*RV1 Combustion Eng. N/A 22003 Replacement Yes 7. Description of work! Replace reactor vessel studs #11 and #40 8. Test Conducted: Ilydrostatic Pneumatic Normal Operating Pressure Other X MT, UT b CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this enlacemej)t rules of ASME Code, Section XI. Signed: 2q.~ l Date: 7, 2 6,'l ; - 8 -MI CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel l Inspectors and the State of Connecticut and employed by liartford Steam Boiler Insurance and Inspection during the period %/97 to f///fS, and state that to the best of my knowledge and belief, the owner has performed examinations and ~ has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissions: g9 va,e; g/ gar f
Form NIS-2 OWNERS RrPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 7/5/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance AWO Numbers M3 9511302 4. SYSTEM: RCS CODE CLASS: 1 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 S 83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3RCS*PIB Westinghouse N/A e-N/A Replacement No 7. Description of work: Replace reactor coolant oump seal housine replacement 8. Test Conducted: Hydrostatic { Pneumatic Normal Operating Pressure X Other k vr-l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI. j > t o-f S N
- L^
Date: 4 3v vF mA Signed: t j CERTIFICATE OF INSERVICE INSPECTION GA"r 4(o5pf+4'fgg 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hanford Steam Boiler Insurance and Inspection during the period 3-di/rf to /,.r.pf, and state that to the best of my knowledge and belief, the owner has performed examinations and tas'taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. l
- By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or le.s of any kind arising from or connected with this inspection.
Inspector's Signature: Commissions: 6//2 y Date: 7////95 / s l l
Form NIS-2 OWNERS AdPORT FOR REPAIRS OR REPLACEMENTS I. OWNER: Northeast Utilities Service Co. Date: 7/20/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance AWO Numbers Address: P. O. Box 128, Waterford CT M3 9513014 4 4. SYSTEM: RCS CODE CLASS: 1 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 S 83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3RCS*V146 Westinghouse See Below N/A Replacement Yes 7. Description of worl : S/N 10000CS880000A000S740002 Replace Studs and Nuts on 3RCS*V146 l 8. Test Conducted: ~ Ilydrostatic Pneumatic Normal Operating Pressure Other i CERTIFICATE OF COMPLIANCE )' We certify that the statements made in the report are correct and this replacement rules of ASME Code, Section XI. ( J-2l) -R E ~ Signed: ' ( e) ~ Date: CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period /$.f 95to 4 v.95' and state that to the best of my knowledge and belief the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, properiy damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissions: br-f Date: 27/9T 4
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMEN FS
- 1. OWNER:
Northeast Utilities Service Co. Date: 07/07/92 P.O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit f.3
- 3. Work Performed By: Betterment Con st.
AWO Numbers Address: P.O. Box 128. Waterford CT M3-91-01165
- 4. SYSTEM: Feedwater Svstem CODE CLASS: 2
- 5. Applicable Const. Code: ASME III.1971 Edition: S2L Addenda: N/A Case Edition of Section XI Utilized for work 1983.S83
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
^ Component Name of Mfrs Nat'l Repair / ASME ID Number Manufacture No. Serial Replacement Stamped 3-FWS-006-062-2 Tioca N/A SAME Replacement YES
- 7. Description of work: Reolace section of oice.
- 8. Test Conducted:
Ilydrostatic < > Pneumatic < > Normal Operating Pressure < X> Other < X > (MT or LP and RT) Certificate of Compliance We certify that the statements made in the report are correct and this reolacement conforms to the rules ASME Code, Section XI dhc b ~ Date: /o' O - 9 3 Signed: CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the M#/ owner hasperiodN#-P/lo 3ePF and state that to the best of my knowledge and belie performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of ny kind arising from or connected with this inspection. inspector's Signature: en N[ Commissions: b#W Datc: /0 // V b' V
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co, Date: 07/07/92 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit 23
- 3. Work Performed By: Maintenance AWO Numbers Address:
P. O. Box 128. Waterford CT M3-91-15688
- 4. SYSTEM:
MSS CODE CLASS: 2
- 5. Applicable Const. Code:
ASME Ill.1971 Edition: E7] Addenda: N/A Case Edition of Section XI Utilized for work 1983.S83
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of M frs. Nat'l Repair / ASME ID Number Manufacture No. Serial Replacement Stamped 3 MSS *SGI A Westinehouse N/A NEGT1776 Replacement YES
- 7. Description of work: Renlaced Manway Boltine. Weld Renair Base Metal and Machine Surface of Manway Cover.
- 8. Test Conducted:
llydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < > CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules c' ASME Code, Section XI Signed: Date: / O-U- N CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period $j_ to /.7 7fR, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: [ b//f,1 Commissions: Date: />Arikr if . m
I Form NIS-2 OWNERS Ru ORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 8-30-94 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 i 3. Work Performed By: Siemen AWO Numbers Address: P. O. Box 128, Waterford CT MP-93-05077 4 4. SYSTEM: RSS CODE CLASS: 2 5. Applicable Const. Code: ASME Ill Edition: 1971 Addenda: S73 j Code Edition of: Section XI Utilized for work 1983,S83 { 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: a t k 1 1 Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped CP-379706.H022 ITT Grinnell I8457 NA Replacement No 7. Description of work: Replacement of Snubbers f 8. Test Conducted: NormalOperating Pressure ] OtherY VT Hydrostatic Pneumatic r CE.RTIFICATE OF COMPLIANCE l We certify that the statements made in the report are correct and this replacement conforms to the rules ) i of ASME Code, Section XI. ) Signed: N3Ab Date: 9-2/- 94 4 I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Ins ectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period i to f#.f.f, and state that to the best of my knowledge and belief, the owner has performed examinations and has 4 t en corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in the Owner's Repon. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or t connected with this inspection. j inspector's Signature: / Commissions: du/19" Date: /p/u/fV
l l Form NIS-2 OWNERS RErORT FOR REPAIRS OR REPLACEMENTS l. OWNER: Northeast Utilities Service Co. Date: 8-26-94 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Siemen AWO Numbers Address: P. O. Box 128, Waterford CT MP-93-05079 4. SYSTEM: BDG CODE CLASS: 2 5. Applicable Const. Code: ASME Ill Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 1983,S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped CP-379706-H025 ITT Grinnell 18462 NA Replacement No 7. Description of work: Snubber replacements during RFO4 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure Other % VT CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conforms to the rules of ASME Code, Section XI. Signed: b u~ k Date: 9' zc
- ?
8 -95 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel In7pectors and pe State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the perio .T@9.5"ZviT to PN8, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissions: -r#f7 Datc: Ek/' f7
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS l 1. OWNER: Northeast Utilities Service Co. Date: 8-30-94 ) P. O. Box 128. Waterford CT i f 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Siemen AWO Numbers Address: P. O. Box 128, Waterford CT MP-93-05080 4. SYSTEM: RSS CODE CLASS: 2 l t 5. Applicable Const. Code: ASME III Edition: 1971 . Addenda: S73 Code Edition of: Section XI Utilized for work 1983,S83 l l 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME j Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped { CP-379707-11022 ITT Grinnell 1751i NA Replacement No [ 7. Description of work: Renlacement of Snubbers 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure Other % VT I CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conforms to the rules of ASME Code, Section XI. Signed: bl-Date: h-2 / -74 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by liartford Steam Boiler Insurance and Inspection during the period f 2 9 % to ff.ff, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. f By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Funbermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Av7/ggi7_ Commissions: hvT7 / Date: 10/rll94
i Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS j i 1. OWNER: Northeast Utilities Service Co. Date: 8-30-94 l P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 l 3. Work Performed By: Siemen AWO Numbers f Address: P. O. Box 128, Waterford CT MP-93-05136 4. SYSTEM: RSS CODE CLASS: 2 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 1983,S83 i 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: l Name of Nat'l Board Repair / ASME Components ID Number Manufacturer M frs. S/N. Number Replacement Stamped CP-379707-11025 ITT Grinnell 18427 NA Replacement No l l 7. Description of work: Renlacement of Snubbers j t 8. Test Conducted: Ilydrostatic ] Pneumatic Normal Operating Pressure Other M VT f I CERTIFICATE OF COMPLIANCE \\ l We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI. f Signed: ( d'h u-b Date: 9-2 / ! CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel l Inspectors and th State of Connecticut and employed by 11artford Steam Boiler Insurance and Inspection during the period f r/r/f7 to 9/1/ff, and state that to the best of my knowledge and belief, the owner has performed examinations and has I t'ak'en corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: amtgy_ Commissions: Arwr7 / Date:.Jf/2//fc/
i Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 8-26-94 P. O. Box 128. Waterford CT l 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Siemen AWO Numbers Address: P. O. Box 128, Waterford CT MP-93-05137 i 4. SYSTEM: BDG CODE CLASS: 2 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 1983,S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped CP-408051-11001 ITT Grinnell 22677.< NA Replacement No i sN 18 721 Rolm+ 7. Description of work: Snubber renlacements during RFO4 8. Test Conducted: Normal Operating Pressure {Other % VT Hydrostatic Pneumatic CERTIFICATE OF COMPLIANCE f We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI. Signed: M A Date: -O E'- Ysn 2E79 4 & Y " # # CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period I//h.f to #v/fS, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or i connected with this inspection. inspector's Si;; nature: Commissions: k#T7 Date: Pk)fS*
1 i .~ ( l 1 Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 1/5/94 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit El
- 3. Work Performed By: Generation Construction AWO Numbers Address:
P. O. Box 128. Waterford CT M3-93-13709 E_SE CODE CLASS: 2
- 4. SYSTEM:
S
- 5. Applicable Const. Code:
ASME III. Edition: 1974 Addenda: EL4 Case Edition of Section XI Utilized for work 1983.S83
- 6. IDENTIFICATION OF COMPONENTS REPA1 RED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No.1 Replacement Stamped 3RSS*MOV23A IIenry Platt D D-Il7-2-1 N/A Replace Yes Pratt mpsn 392-100-1
- 7. Description of work: Eerlaced Valve /Geoltin9
- 8. Test Conducted:
i llydrostatic < > Pneumatic < > Normal Operating Pressure <X > Other < > CERTIFICATE OF COMPLIANCE l We certify that the statements made in the report are correct and this repair / replacement conforms to the rules of ASME Code, Section XI Signed: l m b-Date: b - 9 d 'f CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by liartford Steam Boiler Insurance and Inspection during the period 7/22/93td3/16/94, and state that to the best of my knowledge and belief, the owner. has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. inspector's Signature: ELIZABETH YORK Commissions: ANI/ANII CT1137 ,n Date: 16 JUNE 1994 4 4
~ Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS i
- 1. OWNER:
Northeast Utilities Service Co. Date: 2-11-94 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit U
- 3. Work Performed By: Mamtenance AWO Numbers Address:
P. O. Box 128. Waterford CT M3-93-16897
- 4. SYSTEM:
Qi1 CODE CLASS: 2
- 5. Applicable Const. Code:
ASME III. Edition: 192L Addenda: 322 Code Edition of Section XI Utilized for work 1983.W85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. Serial Replacement Stamped 3CHS*FCV121 Fisher Controls 4 73;76; LA 7 fr Replacement Yes l S/N7317009 NB5764
- 7. Description of work: Replaced stem olus assemb_ly MRIR 391-137-2
- 8. Test Conducted:
Hydrostatic < > Pneumatic < > Normal Orsrating Pressure < X > Other < > 4 CERTIFICATti OF COMPLIANCE i We certify that the statement made m the report are correct and this renair / replacement conforms to the rules of ASME Code. Section XI 1 Signed: A I Date:, 2-I/-9f-i CERTIFICATE OF INSERVICE INSPECTION l 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler i lesurance and Inspection during the perioO8/12/93oO3/23/94 and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. l By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind aris'ng from or connected with this inspection. Inspector's Signature: E YORK Commissions: NB9384 CT1137 Date: 03/23/94 m s -.m .-,,m
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 1/10/94 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit !J
- 3. Work Perfonned By: Generation Construction AWO Numbers Address:
P. O. Box 128. Waterford C,I M 3-93-19551
- 4. SYSTEM:
FWS CODE CLASS: 2 513 O+uer /
- 5. Applicable Const. Code:
ASME III, Edition: 1971 Addenda: W73 @" 6 Case Edition of Section XI Utilized for work 1983.S83
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. Number Replacement Stamped 3-FWS-008-031-02 TUBECO N/A N/A Replacement No
- 7. Description of work: Replace elbow due to erosion
- 8. Test Conducted: Ilydrostatic < X >
Pnewatic < > Normal Operating Pressure < > Other < X > MT,UT,RT CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair / replacement conforms to the rules of ASME Code, Section XI Signed: kkMtw Date: 5'-25. % CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by liartford Steam Boiler Insurance and Inspection during the period f-fg to 5-24-9/, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the O*ner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. I inspector's Signature: /, fd6 e/ @ Commissions: 8raf'/ Date: S/b6/W ~ 7-
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Nonheast Utilities Senice Co. Dese: JAL/24 P. O. Box 128. Waterford CT
- 2. PLANT:
Minaaac Net,2, po,cr Station Unit il
- 3. Work Performed By: Generation Construction AWO Numbers Address:
P. O. Box 128. Waterford CT M3-93-21033 4 SYSTEM: QSS CODE CLASS: 2
- 5. Applicable Const. Code:
ASME III. Edition: 1221 Addenda: SZ1 Case Edition of Section XI Utilized for work 1. 83.W85 9
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. Serial Replacement Stamped 3QSS-012-29-2 Stone & Webster N/A N/A Repair No
- 7. Description of work: Renair of flance misalignment due to cold sprine Hydrostatic < >
Pneumatic < > Normal Operating Pressure < > Other <X> VT RT,LP CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this recair / replacement conforms to the ntles of ASME Code, Scction XI Signed: Ok I Date: 3 i h m CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned holding 21id commission issued tw the National Board of Boiler and Pressure Vessel Inspectors and the State of Nyfind employed by Hartford Steam Boiler lasurance and Inspection du the period 4' M3 to PI M,YnWtate that to the best of my knowledge and belief, the owner has performed cuminations and has taken corrective measures described in this owner's repon in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Repon. Funhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Aud/4 Wh/m Commissions: AV.2Wr Date: <ht/94 l
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 'l. OWNER: Northeast Utilities Service Co. Date: 8-2-95 P. O. Box 128. Waterford CT 2, PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Numbers Address: P. O. Box 128, Waterford CT M3-94-03382 4. SYSTEM: CHS CODE CLASS: 2 ( 5. App. Const. Code: ASMEIII Edition: 1971 Addenda: W73 Code Case: N/A l Code Edition of: SECTION XI Utilized for work 1983 W85 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: i Name of Natl Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped [ 3ClIS'RV8119 LONDERGAN JEL#407487-N/A Replaced N/A f 14 1 P 3CilS*RV8119 LONDERGAN NDB30JS421-N/A Repla: ment N/A T' L 7. Description of work: Replace valve 3CHS*RV8119 j 8. Test Conducted: l Hydrostatic Pneumatic Normal Operating Pressure x Other V1-2 i ( l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, l Section XI. r t 0 ) _a R-Date: 8'S OP Signed: ( _ + i CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel I spect rs and t e State of Connecticut and employed by 11artford Steam Boiler Insurance and Inspection during the period j .7 and state that to the best of my knowledge and belief, the owner has performed examinations and o has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, j Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in the Owner's Repon. Furthermore, neither the inspector i nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from j or connected with this inspection. ] / e 7y 1 ~-----
1 i 1 1 Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Nocheast Utilities Service Co. Date: 7/5/95 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit D [ t
- 3. Work Performed By: Maintenan_cq AWO Numbers Address:
P. O. Box 128. Waterford CT M3-94-06120 l
- 4. SYSTEM:
RHS CODE CLASS: 2 I
- 5. Applicable Const. Code:
ASME III. Edition: 1971 Addenda: S71 Case Edition of Section XI Utilized for work 1983.W85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfts. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped 3RilS*PWra Ingersoll-Rand 077640 234 Replacement Yes L3-I Vf S
- 7. Description of wor'k: Installed the spare RHR pump (Nat. Bd # 395. S/N 1276141 stufFim: box extension (S/N 61987) and replaced the B RHR Po (Nat. Bd #234. S/N 077640.
l
- 8. Test Conducted:
Ilydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < X>VT-2 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replaceme.n_1 conforms to the rules of ASME Code, Section XI Signed: [h% Date: 7- /0 'h_ $ m' CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period (4/pyto 24//PS, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissions:(Py/3,7 JgfDi9/ QM1/f5 Date:
i Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 6/29/95 L O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance AWO Numbers M3 9410631 4. SYSTEM: MSS CODE CLASS: 2 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 S 83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3 MSS *SGI A Westinghouse N/A N/A Replacement No 7. Description of work: Replace Steam Generator Secondary Side Manway Bolts 8. Test Conducted: Ilydrostatic Pneumatic Normal Operating Pressure X Other CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI. Signed: b-Date: ~7 - Io 'd CERTIFICATE OF INSERVICE INSPECTION I, the undersignegdig-;yalid commission issued by the National Board of Boiler and Pressure Inspectors and the State of -~ ~ and employed by 11artford Steam Boiler Insurance and Inspection during the period ,Va/r5 to gffAs, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: bd 4 '77/f//w Commissions: N/.7sp.P Date: _2//r/Pt"
m Form NIS-2 OWNERS IktPORT FOR REPAIRS OR' REPLACEMENTS l . 1.. OWNER: Nonheast Utilities Service Co. Date: 7/24/95 P. O. Fox 128. Waterford CT i 2. PLANT: Millstone Nuclear Power Station Unit 3 1 3. Work Performed By: M.'intenance AWO Numbers Address: P. O. Box 128, Waterford CT M3 9410635 4. SYSTEM: MSS CODE CLASS: 2 5. Applicable Const. Code: ASME III Edition: 1971_ Addenda: S73 Code Edition of: Section XI Utilized for work _ 83 S 83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3 MSS *SG1C Westinghouse N/A N/A Replacement No 7. Description of work": Replace Steam Generator Secondary Side Manway Bolts 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure X Other vr_ s CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement rules of ASME Code, Section XI. Signed: bShul Date: 7-F#s-
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Ndrtheast Utilities Service Co. Date: 11/3/94 P. O. Box 128. Waterford CT 2. PLANT: . Millstone Nuclear Power Station ~ Unit 3 i.., e, 3. Work Performed By: Maintenance ~, AWO Numbers Address: P. O. Box 128, Waterford CT M39416581 4. SYSTEM: MSS CODE' CLASS: 2 5. Applicable Const'.' Code: . ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 1983, W85 I IDENTIFI' ATION OI' COMPONENT,S,MPAIRED OR REPLACED: C 6. Nat'l Board Repair / ASME Name of 3 s. Components ID Number Mangfdcritrer ~ Mfrs. S/N. Number Replacement Stamped Dresser;1ndustries l BS00309 N/A Replacement N/A 3 MSSRV26C' L s 7. Description obvork:. Replace valve 3 MSS *RV2 5C.' S/N BS00309 with certified tested replacement valve from Wvle Lolis S/N BS00296. Perform j ,reolacement work'per AWO M3-94-16581 nnd Maint. Procedure MP a'N h'/ ; 3762 AA. ; s.: .. +\\ t, r .o 8. Test Conducted: ,.3 Hydrostatic Pneumatic Normal Operating Pressure Other X VT-2 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI. Signed: Date: /]-7 #f 7 CERTIFICATE OF INSERVICE INSPECTION inspectors and the State of gjingjalid commission issued by the National Board of Boile 1, the undersigned o re and employed by Hartford Steam Boiler Insurance and Inspection during the period r/c/p/ to (M'/gr, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this cenificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Aao // d *4 f//m Commissions: N.:M9P 4 /.7/9 &~
/j_ l Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 5/9/95 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit !_1
- 3. Work Performed By:
Maintenance AWO Numbers Address: P. O. Box 128. Waterford CT M3-94-16777 4
- 4. SYSTEM:
M.SS CODE CLASS: 2 S
- 5. Applicable Const. Code:
ASME Ill. Edition: 117J Addenda: S73 Case Edition of Section XI Utilized for work 1983.W85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped 3 MSS *PV20A Fisher Controls 8659426 6730 Repair / Replace Yes l
- 7. Description of wor"k: The studs were renlaced with modified studs ner RTE-PSE-MP3E-95-183.
- 8. Test Conducted:
Hydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < > \\1T 'l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI Signed uv Date: 7 "U -9 f CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Conne and employed by llartford Steam Boiler Insurance and Inspection during the period 5d/95to and state that to the best of my knowledge and belief, the owner has performed examinations an s taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. j Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. 6 #f,7 / 8.Td [ Inspector's Signature: Commissions: Date: {/ 7/f.7
=. i Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 5/9/95 ~> P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit #_1
- 3. Work Performed By: Maintenance AWO Numbers Address:
P. O. Box 128. Waterford CT M3-94-16826
- 4. SYSTEM:
hiss CODE CLASS: 1
- 5. Applicable Const. Code:
ASME IIL Edition: 1971 Addenda: S23 Case Edition of Section XI Utilized for work 1983.W85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped 3 MSS *PV20B Fisher Controls 8659427 6766 Repair /Replece Yes
- 7. Description of work: The studs were replaced with modified studs ocr RIE-PSE-MP3E-95-183.
- 8. Test Conducted:
Hydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < Vr L CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI Signed: -- bo Date: 7 - h Ji ( i t CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period MA to 7/vMrand state that to the best of my knowledge and belief, the owner has perfonned examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed l or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kin arisin from or connected with this inspection. Inspector's Signature: Commissions; h#.77 x Date: / MMS 7-L..
T i t Form NIS 2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 5/9/95 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit D
- 3. Work Performed By: Maintenance AWO Numbers Address:
P. O. Box 128. Waterford CT M3-94-16827 i
- 4. SYSTEM:
MSS CODE CLASS: 2
- 5. Applicable Const. Code:
ASME Ill Edition: 1971 Addenda: S71 Case Edition of Section XI Utilized for work 1983.W85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfts. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped 3 MSS *PV20C Fisher Controls 8659428 6767 Repair / Replace Yes
- 7. Description of work: Durine disassembly of the valve. one of the tanned threads in the valve body was found to be cross threaded NCR 395-21I was cenerated to allow removal of the crossed threads. Also. the studs were replaced with a modified stud per RIE-PSE-MP3E-95-183. Four (4) nuts were also replaced due to calline.
- 8. Test Conducted:
Hydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < V r - 1. CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Leplacement conforms to the rules of ASME Code, Section XI 1 -O-Date: ?-31-9 s Signed: CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connec)icuj and employed by Hartford Steam Boiler Insurance and Inspection during the period f/df to 7/g/fj', and state that to the best of my knowledge and f belief, the owner has performed c/ammations lnd has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this cenificate neither the inspector not his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Funhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind a ' ing from or connected with this inspection. inspector's Signature: Commissions: h/57 Date: 7/h/O' vr p v
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
No,rtheast Utilities Service Co Date: 5/9/95 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit 13
- 3. Work Performed By: Maintenance AWO Numbers Address:
P. O. Box 128. Waterford CT M3-94-16828
- 4. SYSTEM:
MSS CODE CLASS: 2 4
- 5. Applicab!c Const. Code:
ASME IIL Edition: 1971 Addenda: S73 Case Edition of Section XI Utilized for work 1983.W85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped 3 MSS *PV20D Fisher Controls 8659429 6731 Repair / Replace Yes
- 7. Description of work: The studs were replaced with modified studs per RIE-PSE-MP3E-95-183.
- 8. Test Conducted:
Hydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI Signed /u Date: P/h CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid conunission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period #9/f5 to J/gt&ff~and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owmer's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind ising from or connected with this inspection. Inspector's Signature: Commissions: h#.7'7 Date: 7/ZdkS~ \\ m e ?s#2r. 1 r
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 6-5-95 P O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance AWO Numbers Address: P. O. Box 128, Waterford CT M3-94-20524 k 4. SYSTEM: Main Steam - MSS CODE CLASS: Class 2 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 1983,S83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Components ID Name of Nat'l Board Repair / ASME Number Manufacturer Mfrs. S/N Number Replacement Stamped 3 MSS
- AOV31 A Fisher Controls 73110076 NB 5684 Replacement Yes 7.
Description of work: Replace plug / stem assembly one-for-one 8. Test Conducted: liydrostatic Pneumatic Normal Operating Pressure Other x CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (circle one) conforms to the rules of ASME Code, Section XI. Signed:
- /[W Date:
6 % / CERTIFICATE OF INSERVICE INSPECTION 1, the undersignedgoyig a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of mamu,Ebd employed by Hartford Steam Boiler Insurance and Inspection during the period ,/ zaffsto fgr/xfand state that to the best of my knowledge and belief, the owner has performed examinations and has / taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Me//d'. 77/gm / Commissions: A.rwr# Date: 6/.5/9s _
l Form NIS-2 OWNERS RrPORT FO.R REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 7/5/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance AWO Numbers M3 94 21625 4. SYSTEM: MSS CODE CLASS: 2 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 S 83 J 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3 MSS *SGlB Westinghouse N/A N/A Replacernent No 7. Description of work: Replace Steam Generator Secondary Side Manway Bolts 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure Other CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI. Signed: do Date: 7-/e-96 N CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inypectors and the State of Connecticut and employed by liartford Steam Boiler Insurance and Inspection during the period /f#f$~ to /[I.[*r, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken correciive measures described in this owner's repon in accordance with the requirements of ASME Code, Section XI. By signing this cenificate neither the inspector nor his employer makes any warranty, expressed or implied. conceming the examinations and corrective measures described in the Owner's Report. Funhermore, neither the inspector ner his employer shall be liable in any manner for any personal injury, propeny damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissions: drp:T7 Date: 7////$r"
~_ 1 1 /, = Form NIS-2 OWNERS REi ~ AT FOR REPAIRS OR REPLA..MENTS 1, OWNER: Northeast Utilities Service Co. Date: 07/13/95 P. O. Box 128. Waterford CT 2. PIANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance Services AWO Numbers j Address: P. O. Box 128, Waterford CT M3-95-00941 4. SYSTEM: QSS CODE CLASS: 2
- 5. --Applicable Const. Code:
ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 W 85 Code Case N-416-1 i (Per ISI 5/27/95) 1 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME i Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3QSS-006-006-64-2 Tioga Pipe Supply Co N/A N/A Modification No 7. Description of work: Design change which deletes the use of the CAT. Cut and cap the subject line. Abandon in place all lines downstream the cap. 8. Test Conducted: i Ilydrostatic X Pneumatic Normal Operating Pressure X Other i CERTIFICATE OF COMPLIANCE i We certify that the statements made in the report are correct and this modification conforms to the rules of ASME Code, Section XI. Signed: // Date: 7-l3 0 [ 1 v / CERTIFICATE OF INSERVICE INSPECTION 1, the undersignedgi a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of m=g;InTemployed by llartford Steam Boiler Insurance and Inspection during t c i ,//u/r.sto r/aAtc and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, i Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. inspector's Signature: d/ d. Wg//m Commissions:. W,a V FF-Date: '7/'2/9 s~
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: P. O. Box 128. Waterford CT i 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance Services AWO Number Address: P. O. Box 128, Waterford CT M3-95-00944 4. SYSTEM: SIL CODE CLASS: 2 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 W 85 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3 SILTKI A Southwest Fab & 0003 293 Replacement N (manway cover) Welding 2 7. Description of work: Welded bracket to manway cover for seismic monitor mounting (PDCR MP3-94-165) ~ 8. Test Conducted: Ilydrostatic Pneumatic Normal Operating Pressure Other XlMT CERTIFICATE OF COMPLIANCE j We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI. Egy,g-I Signed: ., [ Date: CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, oldi a v31id commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of _ gnm an"Il employed by llartford Steam Boiler Insurance and Inspection during th //g/arto g/pgrand state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: A f, W / d M 9 ff f w Commissions:,at,V.:2,/ 9,p Date: / /.90/95 i
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 2-16-95 P. O. Box 128. Waterford CT 2. PLANT Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Numbers Address: P. O. Box 128, Waterford CT M3-95-01082 4. SYSTEM: Recire. Spray CODE CLASS: 2 '5. App. Const. Code: ASME III Edition: 1971 Addenda: S73 Code Case: N/A Code Edition of: Section XI Utilized for work 1983, W85 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replaccment Stamped Z102 Graver Tank & Mfg. N/A 8392 Replacement NPT Z103 N/A 8393 Z104 N/A 8394 Z105 N/A 8395 7. Description of work: Install fabricated flanges on the penetrations per PDCR 3-94-162 LLRf.MD r/4 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure Other x AR-T CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of AShE Code, Section XI. Date: r-Signed:_ CERTIFICATE OF INSERVICE INSPECTION I, the undersigned,pigdg commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of ~r 1,a; and employed by Hartford Steam Boiler Insurance and Inspection during the period #at/vt to #Ar/pt, and state that to the best of my knowledge and belief, the owner has performd examinations and has taken corrective measures described in this owner's report in accordance with the requirements of AShE Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: / e // d 7 I// w Commissions: d/:WPr Date: MAP /9.r
1 Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 1/llM P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit!)
- 3. Work Performed By: Maintenance AWO Numbers Address:
P. O. Box 128. Waterford CT M3-95-01199
- 4. SYSTEM:
MSS CODE CLASS: 2 1
- 5. Applicable Const. Code:
ASMEIll. Edition:J174 Addenda: 17_4 Case Edition of Sgetion XI Utilized for work 1983.W85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
i Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped l 3 MSS *RV22B Dresser BS00295 N/A Replacement Yes
- 7. Description of work: Replacsd_ Safety Valve with Spare S/N BS00299: replaced disk with soare S/N e
i ACLl7. i
- 8. Test Conducted:
Hydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < > V T - L 1 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Leplacement conforms to the rules of ~ ASME Code, Section XI Signed: 4v Date: 7- /0 h g4 qg e i j CERTIFICATE OF INSERVICE INSPECTION l! I, the undersigned, holding a valid commission issued by the National Board of Boiler and i Pressure Vessel, Inspectors and the State of Conne ticut and employed by Hartford Steam Boiler Insurance j-and Inspection during the period t / #S, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's 4 report in accordance with the requirements of ASME Code, Section XI. By signing this certincate neither the inspector nor his employer makes any warranty, expressed - or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable"in any manner for any personal injury, property damage, or loss of an kind ising from or connected with this inspection. Inspector's Signature: Commissions: b/77 l j ' Date:[ f 1 4 4
Form NIS.2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Uli.lities Service Co. Date: 3/11/25 P. O. Box 128. Waterford CT
- 2. PLANT:
Millane Nuclear Power Station Unit #.3
- 3. Work Perfarmed By:
Maintenance AWO Numbers Address: P. O. Box 128. WpterfenlCI M3-95-01200
- 4. SYSTEM:
MSS CODE CLASS: 2
- 5. Applicable Const. Code:
ASME III Edition: 19 14 Addenda: S14 Case Edition of Sgction XI Utilized for work 1983.W85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfts. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped 3 MSS *RV22C Dresser BS00292 N/A Replacement Yes
- 7. Description of work: Replaced Safety Valve with Spare S/N BS00307aeplaced disk with spare S/N ACLift
- 8. Test Conducted:
uG 1 Hydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < > 7-CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI Signed: Date: *7<J '.S b~ b -9 $ / CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure VesselInspectors and the Stpte yf Connectiput and employed by llartford Steam Boiler Insurance and Inspection during the period 3/f//6to<f/M/fS, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his mployer shall be liable in any manner for any personal injury, property damage, or loss of an -i ari ng from or connected with this inspection. Inspector's Signature: 1 Commissions: [-77ff Date:...f. /'5 /
i r 1 Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- l. OWNER:
Northeast Utilities Service Co. Date: 3/17/95 i P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit M
- 3. Work Performed By: Maintenangs AWO Numbers Address:
P. O. Box 128. Waterford CT M3-95-01201 j
- 4. SYSTEM:
MSS CODE CLASS: 2 l t
- 5. t.pplicable Const. Code:
ASMEIIL Edition: 1224 Addenda: 314 Case Edition of Section XI Utilized for work 1983.W85 i j
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
J Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped 3 MSS *RV22D Dresser BS00293 N/A Replacement Yes
- 7. Description of work < Replaced Safety Valve with Spare S/N BS00303: replaced disk with spare S/N ACM56.
- 8. Test Conducted:
V T-L l l', T.;,, sf
- N l
liydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < > 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI I '7-Z.9'ff , i. w Signed: A Date: u sw CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the St te of ConnecJicut and employed by Hartford Steam Boiler Insurance d /ff to 7hT y, and state that to the best of my knowledge and and Inspection during the period belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind ing from or connected with this inspectian. Commissions:b#T7M,/[ Inspector's Signature: ~ Date: I j
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service C(L Date: 3/17/95 P. O. Box 128. Waterford CT
- 2. PLANT.
Millstone Nuclear Power Station Unit U
- 3. Work Performed By: Mainten.a_ngs AWO Numbers Address:
P. O. Box 128. Waterford CT M3-95-01202
- 4. SYSTEM:
MSS CODE CLASS: 2
- 5. Applicable Const. Code:
ASME III. Edition: 1974 Addenda:324 Case Edition of Section XI Utilized for work 1983.W85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / - ASME ID Number Manufacture S/N. No. Replacement Stamped 3 MSS *RV25D Dresser BS00306 N/A Replacement Yes 7, Description of work:. Rgplaced Safety Valve with Spare S/N BS00305: replaced disk with spare S/N ACM 12.
- 8. Test Conducted:
Ilydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < > VT-L CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI 1 Signed: /p Date: C1'! B -- 9 5 1w-k CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure VesselInspectors and the State o ConnecJicu} and employed by Hartford Steam Boiler Insurance and Inspection during the peri - to 7//5d:f~and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this ov ter's report in accordance with the requirements of ASME Code, Section XL By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, 4 property damage, or loss of any kind ari ing from or connected with this inspection. Inspector's Signature: __ _ hr Commissions: h#77 Date: FM 5" 7
l 1 j Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 3/17/95 P, O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit _#3
- 3. Work Performed By:
MainteJance AWO Numbers Address: P. O. Botl28. Waterford CT M3-95-01203
- 4. SYSTEM:
MSS CODE CLASS: 2
- 5. Applicable Const. Code:
ASME III. Edition: 1921 Addenda: S23 Case Edition of SectionXI Utilized for work 1983.W85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped 3 MSS *RV26B Dresser BR06741 N/A Replacement Yes
- 7. Description of worki Replaced Safety Valve with Sgare S/N BS00309: replaced disk with spare S/N
- ACM13,
- 8. Test Conducted:
Hydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < > \\/ T- % CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Irplacement conforms to the rules of ASME Code, Section XI 7' # Ii h Date: Signed: CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by llartford Steam Boiler Insurance and Inspection during the periodJhfr to Mdfrand state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employ:r makes any warranty, expressed or. implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, i property damage, or loss of any kin arising from or connected with this inspection. ) Inspector's Signature: Commissions: hAd7 Date: ef 5
d.. Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 2-14-95 ~> P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Numbers Address: P. O. Box 128, Waterford CT M3-95-02237 4. SYSTEM: Main Steam CODE CLASS: 2 Addenda:h73 Code Case: 1334-3/ 5. App. Const. Code: ASME III Edition: 1971 1727 Code Edition of: Section XI Utilized for work 1983, W85 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3 MSS *CTV27A Sulrcr 5425 1 N/A N/A 7. Description of work: Drill and tap piston cylinder for valve 3 MSS *CTV27A and install new control blocks 8. Test Conducted: Other V T '2.- Hydrostatic Pneumatic Normal Operating Pressure x CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this modification conforms to the rules of ASME Code, Section XI. Signed: c'"'%, M Date: / 4 -I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and t)ie State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period .3/Sto f/5/M" and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personalinjury, property damage, or loss of any kind arising from or connected with this inspection. Commissions: hET7 / // Inspector's Signature: Date:
1 Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 2-14-95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Nurnbers Address: P. O. Box 128, Waterford CT M3-95-02240 4. SYSTEM: Main Steam CODE CLASS: 2 5. App. Const. Code: ASME III Edition: 1971 Addenda:h73 Code Case: 1334-3/ 1727 Code Edition of: Section XI Utilized for work 1983, W85 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3 MSS *CTV27B Sulzer 5431 2 N/A N/A 7. Description of work: Drill and tap piston cylinder for valve 3 MSS *CTV27B and install new control blocks 8. Test Conducted: Other yr n Hydrostatic Pneumatic Normal Operating Pressure x CERTIFICATE OF COMPLIANCE We certify that the statements made in the report r.re correct and this modification conforms to the rules of ASME Code, Section XI. OA /i' Signed: Date: CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel In. ec ors and t e tate of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period to j '~, and state that to the best of my knowledge and belief, the owner has performed examinations and 3 has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. / hY /SM Commissions:h/I,F ,/8 Inspector's Signature: Date: ( (
i Form NIS-2 OWNERS RiiPORT FOR REPAIRS OR REPLACEMENTS n te: 7/5/95 1. OWNER: Northeast Utilities Service Co. a P. O. Box 128. Waterford CT ~.i 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Construction AWO Numbers M3 95 02242 4. SYSTEM: MSS CODE CLASS: 2
- 5. ' Applicable Const. Code:
ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 S 83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3 MSS *CTV27C Sultzer 5437 3 Modification Yes 7. Description of worib: Drill and tap piston cylinder for valve 3 MSS *CTV27C. Install modified control blocks. /ga ffpug 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure X Other vr-L CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this modification conforms to the rules of ASME Code, Section XI. Signed: - %%:a Date: '7 -/o M CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Ins ctors and ie State of Connecticut and employed by liartford Steam Boiler Insurance and Inspection during the period / to ., and state that to the best of my knowledge and belief, the owner has performed examinations and ~has taken corrective measures, described in this owner's report in accordance with the requirements of ASME Code, Section'XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissions: b/f37 .F, A S* Date:
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 2-14-95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Numbers Address: P. O. Box 128, Waterford CT M3-95-02243 4. SYSTEM: Main Steam CODE CLASS: 2 N 1 Code Case: 1334-3/ 5. App. Const. Code: ASMEIII Edition: 1971 Addenda: 1727 Code Edition of: Section XI Utilized for work 1983. W85 6. IDENTIFICATION OF COMPONENTS REFAlfGD OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3 MSS *CTV27D Sulzer 5443 4 N/A N/A 7, Description of work: Drill and tap piston cylinder for valve 3 MSS *CTV27D and install new control blocks t 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure x Other vr L CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this modification conforms to the rules of ASME Code, Section XI. )~/O' Signed Date: CERTIFICATE OF INSERVICE INSPECTION i I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel In ctors and tije State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period 44 Go 7 3 5 and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, l t l Section XI. i By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor 10s employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. 6 i-l 1 -.-m c__
l ll-Form NIS-2 OWNERS i _./ ORT FOR REPAIRS OR REPL. 2EMENTS l 1, OWNER: Northeast Utilities Service Co. Date: 04/03/95 P O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance Services AWO Numbers Address: P. O. Box 128, Waterford CT M3-95-02567 4. SYSTEM: CVS CODE CLASS: 2 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 S 83 Code Case N/A 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of - Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3CVS*V20 Walworth Company A3343 1321 Modification Yes 7. Description of work: Replace the manual 8" Walworth metal seated gate valve with a manual 8" soft-seated Henry Pratt wafer-style butterfly valve (Model 1200), along with accompanying 8" 150# RF flange. Ilydrostatic J' hlJk( , $(V {d 8. Test Conducted: Pneumatic g Normal Operating Pressur Other )( QT Qf qi CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this modification conforms to the rules of ASME Code, Section XI. Signed: 41 Date: 7- /4dh CERTIFICATE OF INSERVICE INSPECTION I, the undersignedggdg bd employed by liartford Steam Boiler Insurance an valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of c m.=j on during the period y//fAtr to g/ p/ grand state that to the best of my knowledge and belief, the owner has performed examinations and has A taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector i nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. inspector's Signature: Mu,// d. 7//[//w Commissions: N/.MPP Date: 7Mo/PI
's Form NIS-2 OWNERS ! PORT FOR REPAIRS OR RL LACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 3/8/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance AWO Numbers Address: P. O. Box 128, Waterford CT M3-95-03049 4. SYSTEM: RHS CODE CLASS: 2 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 1983, W85 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3RHf* PIA Ingersoll-Rand 077639 233 Replacement Yes a 4 7. DFs ption of work: From the B RHR numn (Nat. Bd # 234.S/N 077639 also 0576-154) e removed the stuffine box extension (S/N 62008) and replace the A Pn (Nat. Bd # 233. S/N 077639 or S/N 0576-14) Stuffine box extension S/N 62005 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure Other X VT-2 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules i of ASME Code, Section XI. Date: S //95' f akl Signed: w,e m L. CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period 73Yff o <//a/v.Cand state that to the best of my knowledge and belief, the owner has performed examinations and har t taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection. [ h#P7 g(yf Inspector's Signature: Commissions: f Date: //k
\\ \\ Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 7-14-95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Numbers Address: P. O. Box 128, Waterford CT M3-95-5427 4. SYSTEM: CHS CODE CLASS: two 5. App. Const. Code: ASMEIII Edition: 71 Addenda: S73 Code Case: N/A Code Edition of: ASME X1 Utilized for work 85 W85 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME ~ Components ID Number Manufacturer Mfrs. S/N. Number Replacemen' Stamped 3CHS00204402 SWEC N/A N/A N/A N/A 7. Description of work: No Section XI work was nerformed under this AWO. 8. Test Conducted: Hydrostatic Pneumatic Normal Operating Pressure Other N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conforms to the rules of ASME Code, Section XI. Signed: M, -- v .E Date: CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period to , and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: M " Commissions: Date: J
Fonn NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 7-14-95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Numbers Address: P. O. Box 128, Waterford CT M3-95-05481 4. SYSTEM: CIIS CODE CLASS: two 5. App Const. Code: ASME III Edition: 71 Addenda: S73 Code Case: N/A Code Edition of: ASME XI Utilized for work 85 W85 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3CHS00205402 SWEC N/A N/A N/A N/A 7. Description of work: No Section XI work was performed under this AWO. 8. Test Conducted: Ilydrostatic l l Pneumatic l Normal Operating Pressure l Other l l N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conforms to the rules of ASME Code, Section XI. m &/m 7-IW 9 % /A -A Date: S.igned: / V CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period to , and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. NA Inspector's Signature: Commissions: Date: / 1
j Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 5/2/95 ~ P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit M
- 3. Work Performed By: Maintenance AWO Numbers Address:
P. O. Box 128. Waterford CT M3-95-08312
- 4. SYSTEM:
MSS CODE CLASS: 2
- 5. Applicable Const. Code:
ASME III. Edition:1224 Addenda: S24 -{asetdition of Section XI Utilized for work 1983.W85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mirs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped 3 MSS *RV26C Dresser BS00296 N/A Replacement Yes
- 7. Description of work: Replaced Safety Valve with Snare S/N BR06741: renlaced disk with snare S/N ACM58
- 8. Test Conducted:
liydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < > VT '2 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this gplacement conforms to the rules of ASME Code, Section XI q ~
- ) - Z 5 C) C"~~
\\ M e, t - ,o Signe Date: /s i; - 1 X ~ CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the St3te of Connecticut and employed by Hartford Steam Boiler Insurance and Inspection during the period,0ff/ff to ////9.6~, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Funhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or less of a kind ising from or connected with this inspection. Inspector's Signature: Commissions: h/// Date: ss
Form NIS-2 OWNERS REPORT FOR REPAIRS OR IEPLACEMENTS
- 1. OWNER:
Northeast Utilities Service Co. Date: 5/2/95 P. O. Box 128. Waterford CT
- 2. PLANT:
Millstone Nuclear Power Station Unit M
- 3. Work Performed By:
Maintenance AWO Numbers Address: P. O. Box 128. Waterford CT M3-95-08313
- 4. SYSTEM:
MSS CODE CLASS: 2
- 5. Applicable Const. Code:
ASME Ill. Edition: 1914 Addenda: S24 Case Edition of Section XI Utilized for work 1983.W85
- 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED:
Components Name of Mfrs. Nat'l Board Repair / ASME ID Number Manufacture S/N. No. Replacement Stamped 3 MSS
- RV22A Dresser BS00290 N/A Replacement Yes
- 7. Description of work: Replaced Safety Valve withSpare S/N BS00292: replaced disk with snare S/N ACM57
- 8. Test Conducted:
Ilydrostatic < > Pneumatic < > Normal Operating Pressure < X > Other < > UT-1,. l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI Signed Date: 7-/o-98 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Conneyticut and employed by llartford Steam Boiler Insurance and Inspection during the period $1 to f/d, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures describd in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind - sing from or connected with this inspection. Inspector's Signature: _i Commissions: g.77 Date:[hlff
Form NIS-2 OWNERS RcPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 6/30/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Maintenance AWO Numbers M3 95 08934 4. SYSTEM: MSS CODE CLASS: 2 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 S 83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3 MSS *PV20D Fisher Controls Inc. 8659429 6731 Repair Yes Description of worlk: Repair of "D" Atmoshneric Dump Valve 7. 8. Test Conducted: . ormal Operating Pressure X Other X NT' & Ilydrostatic Pneumatic N S*& CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of ASME Code, Section XI. 4 Date: 6 - 3 o ' 75~ Signe r CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Doder and Pressure Vessel Inspectors and the State of Connecticut and employed by llartford Steam Boiler Insurance and Inspection during the period 74/f,7_ to g/ppf, and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property darnage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: Commissions: &//M Date: /95 l
I Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER: Northeast Utilities Service Co. Date: 7/18/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 i 3. Work Performed By: Maintenance AWO Numbers Address: P. O. Box 128, Waterford CT M3 95 09969 4. SYSTEM: CIIS CODE CLASS: 2 5. Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 S 83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3CilS*AOV71 Stone & Webster N/A N/A Replacement N/A 7. Description of world: Renlace Studs and Nuts for Valve 3CHS*AOV71 8. Test Conducted: IIydrostatic ] Pneumatic { Normal Operating Pressure ] Other CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement concur with rules of ASME Code, Section XI. 31 b Signed: hv Date: ~ s o CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Connecticut and employed by Hanford Steam Boiler Insurance and Inspection during the period fE/95 to g.pA and state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's repon in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Funhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, propeny damage, or loss of any kind arising from or connected with this inspection, i A Commissions: 6#I7 Inspector's Signature: ~ ~,ew,c 7~ w -s -m a+ e
t I Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS j l. OWNER: Northeast Utilities Service Co. Date: 6-15-95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Northeast Utilities AWO Numbers Address: P. O. Box 128, Waterford CT g.s - ps_ ars p 4. SYSTEM: MSS CODE CLASS: 2 5. App. Const. Code: ANSI B31.1 Edition: 71 Addenda: 6-71 Code Case: Code Edition of: Section XI Utilized for work 1983 W85 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped 3M SS-1-PSSH 128 ITF Grinell N/A N/a Repair No 3 MSS-1-PSSH129 ITT Grinell N/A N/a Repair No 7. Description of work: Repair spring hangers to eliminate interference with main pivot tab. 8. Test Conducted: Ilydrostatic Pneumatic Normal Operating Pressure Other x VT-3 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of ASME Code, Section XI. Signed: )~ 9-Date: b - II-T C v CERTIFICATE OF INSERVICE INSPECTION I. the undersignedgo aplid commission issued by the National Board of Boiler and Fressure Vessel Inspectors and the State of _ jdigIand employed by Hartford Steam Boiler Insurance and Inspectio 4/.7/kr to f/pdP4Tmd state that to the best of my knowledge and belief, the owner has performed examinations and has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: m // 8 MW-Commissions: A/ M U F Date: _f/_,P e/7d* 1 j i i
Form NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS 1. OWNER.: Northeast Utilities Service Co. Date: 6/29/95 P. O. Box 128. Waterford CT 2. PLANT: Millstone Nuclear Power Station Unit 3 3. Work Performed By: Construction AWO Numbers M3 95120I5 4. SYSTEM: SIL CODE CLASS: 2 5... Applicable Const. Code: ASME III Edition: 1971 Addenda: S73 Code Edition of: Section XI Utilized for work 83 S 83 6. IDENTIFICATION OF COMPONENTS REPAIRED OR REPLACED: Name of Nat'l Board Repair / ASME Components ID Number Manufacturer Mfrs. S/N. Number Replacement Stamped SIL-152 A-FW-2-3 M SWFW 21939 N/A Repair Yes 7. Description of work: Repair of Weld 8. Test Conducted: Ilydrostatic Pneumatic Normal Operating Pressure Other X LP CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of ASME Code, Section XI. ] R%twU G 15 Signed: Date: CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned Id yalid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of m m and employed by Ilartford Steam Boiler Insurance and Inspection during the period gggg/gsto 9/rr/ grand state that to the best of my knowledge and belief, the owner has performed examinations and i has taken corrective measures described in this owner's report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury, property damage, or loss of any kind arising from or connected with this inspection. Inspector's Signature: d%Il d. ;46L Commissions: a/d 6 a; & Date: 3/srhq l
P 8.0 Drawings / Location (zone) Isometrics A list of RF05 location Isometrics is provided as a reference. The list is sorted by zone throughout this report to be consistent with the ISI program plan. i i m, i i t t 6 I t I 6 2 I 6 f 1 f I i e 13
\\ MILLSTONE UNIT 3 RF05 ZONE / DRAWING REFERENCE NIS 1 ZONE DRAWING LOCATION 001 25212-20900-SH.1 CONT. BLDG. - REACTOR PRESSURE VESSEL 25212-20900-SH.2 CONT. BLDG. - REACTOR PRESSURE VESSEL 002 25212-20900-SH.3 COW. BLDG. - REACTOR PREaSURE VESSEL HEAD 003 25212-20901 CONT BLDG. - STEAM GENERATOR 1 A 004 25212-20902 CONT. BLDG. - STEAM GENERATOR IB 005 25212 20903 CONT. BLDG. - STEAM GENERATOR IC 006 25212-20904 CONT. BLDG. - STEAM GENERATOR ID 007 25212-20905 CONT. BLDG. - ELEV. 3'-8 PRESSURIZER CUBICE 008 25212-20906-SH.1 CONT, BLDG. - ELEV. 3'-8 LOOP A 25212 20914 CONT. BLDG. - ELEV. 3'-8 LOOP A 009 25212-20907-SH.1 CONT. BLDG. - ELEV. 3'-8 LOOP B 010 25212-20908-SH.1 CONT. BLDG. - EEV. 3'-8 LOOP C a 011 25212-20909-SH.1 CONT. BLDG. - ELEV. 3'-8 LOOP D 011H 25212-20900-SH.11 CONT. BLDG. - EEV. 3'-8 LOOP D 012 25212-20910 CONT. BLDG. - EEV. 3'-8 LOOP A 013 25212-20911 CONT. BLDG. - EEV. 3'-8 LOOP B 014 25212-20912 CONT. BLDG. - ELEV. 3'-8 LOOP C 015 Report: rptZoneDwgReference Page 1 of 8 Sorted: Zone / Drawing / Location
ZONE DRAWING LOCATION 25212-20913 CONT. BLDG. - ELEV. 3'-8 LOOP D 017H 25212-20900-SH.17 CONT. BLDG. - ELEV.17'-0 PRESSURIZER CUBICE 25212-20900-SH.17 CONT. BLDG. - EEV. 54'-0 PRESSURIZER CUBICE 018 25212-20920 CONT. BLDG. - EEV.17'-6 PRESSURIZER CUBICLE 018H 25212-20900-SH.18 CONT. BLDG. - EEV. 21'-0 PRESSURIZER CUBICLE 25212-20900-SH.18 CONT. BLDG. - ELEV. 52'-0 PRESSURIZER CUBICLE 25212-20900-SH.18 CONT. BLDG. - ELEV. 54'-0 PRESSURIZER CUBICLE o19H 25212-20900-SH.19 CONT. BLDG. - ELEV. 80'-0 PRESSURIZER CUBICLE 25212-20900-SH.19 CONT. BLDG - EEV. 00'-0 PRESSURIZER CUBICLE 25212-20900-SH.19 CONT. BLDG. - EEV. 58'-0 PRESSURIZER CUBICLE 25212-20900-SH.19 CONT. BLDG. - EEV. 70'-0 PRESSURIZER CUBICLE l 021 25212-20923 CONT. BLDG. - EEV. 75'-0 PRESSURIZER CUBICE 922 25212-20924 CONT. BLDG. - ELEV. 3'-8 LOOP A 022H 25212-20900-SH.22 CONT BLDG. - ELEV. 3'-8 LOOP A 023 l 25212-29925 CONT. BLDG. - ELEV. 3'-8 LOOP B l l 023H 25212-20900-SH.23 CONT. BLDG. - ELEV. 3'-8 LOOP B 024 25212-20926 CONT. BLDG. - ELEV. 3'-8 LOOP B 25212-20926 CONT. BLDG. - ELEV. 3'-8 OUTER ANNULUS 024H 25212-20900-SH.24 CONT. BLDG. - ELEV. 3'-8 LOOP B 015 25212-20927 CONT. BLDG - ELEV. 3'-8 LOOP C 025H 25212-20927-SH.25 CONT. BLDG. - ELEV. 3'-8 LOOP C 026H 25212-20927-SH.25 CONT. BLDG. - E&V. 3'-8 LOOP D ) i Report: rptZoneDwgReference Page 2 of 8 i Sorted: Zone / Drawing 4.ocation l L ___.________m.___ __m____.___
ZONE IsRAWING LOCATION 028 25212 20930 CONT. BLDO. - ELEV. 3'-8 LOOP D 25212-20930 CONT. BLDG. - ELEV. 3'-8 OUTER ANNULUS 028H 25212-20900-SH.28 CONT. BLDG. - ELEV. 3'-8 OUTER ANNULUS 029H 25212-20900-SH.29 CONT. BLDG. - EEV. 3'-8 LOOP A 030 25212-20932 CONT. BLDG. - ELEV. 3'-8 LOOP B 030H 25212-20900-SH.30 CONT. BLDG. - ELEV 3'-8 LOOP B 031 25212 20933 CONT. BLDG. - EEV. 24'-0 LOOP C 031H 25212-20900-SH.31 CONT. BLDG. - ELEV. 24'-0 LOOP C 032 25212-20934 CONT. BLDG. - EEV. 24'-0 LOOP D 032H 25212-20900-SH.32 CONT. BLDG. - EEV. 24'-0 LOOP D 038 25212 20940 CONT. BLDG. - ELEV. 3'-8 LOOP B 038H 25212-20900-SH.38 CONT. BLDG. - EEV. 3'-8 LOOP B 039 25212-20941 CONT. BLDG. - ELEV. 3'-8 LOOP C 040 25212-20942 CONT. BLDG. - ELEV. 3'-8 OUTER ANNULUS 25212-20942 CONT. BLDG. - ELEV. 3'-8 LOOP C 040H 25212-20900-SH.40 CONT. BLDG. - ELEV. 3'-8 LOOP C 041 25212-20943 CONT. BLDG - ELEV. 3'-8 LOOP D 25212-20943 CONT. BLDG. - EEV. 3'-8 OUTER ANNULUS 041H l 25212-20900-SH.41 CONT. BLDG. - EEV. 3'-8 OUTER ANNULUS Report: rptZoneDwgReference Page 3 of 8 Sorted: Zone / Drawing / Location
ZONE DRAWING LOCATION 042 25212-20944 CONT. BLDG. - ELEV. 3'4 LOOP A 942H 25212-20900-SH.42 CONT. BLDG. - ELEV. 3'-8 LOOP A 048 25212-20950 CONT. BLDG. - ELEV 3'4 LOOP A 25212-20950 CONT. BLDG. - ELEV. 3'4 LOOP D 048H 25212 20900-SH.48 CONT BLDG. - ELEV. 3'4 LOOP A 049H 25212-20900-SH.48 CONT. BLDG. - ELEV. Il'-0 LOOP B 050 25212-20952 CONT. BLDG. - ELEV. 3'-8 LOOP C 051 25212-20953 CONT. BLDG. - ELEV. 3'-8 LOOP C 051H 25212-20900-SH.51 CONT. BLDG, - ELEV. 3'-8 LOOP C 052 25212-20954 CONT. BLDG. - ELEV. 3'-8 LOOP D 052H 25212 20900-SH.52 CONT. BLDG. - ELEV. 3'-8 LOOP D 053 25212-20955 CONT. BLDG. - STEAM GEN.1 A 057 25212-20959 CONT. BLDG. - ELEV. 51'-0 OUTER ANNULUS 058 -25212-20960 CONT BLDG. - ELEV. 51'-0 OUTER ANNULUS 058H 25212-20900-SH.58 CONT. BLDG. - ELEV. 51'-0 OUTER ANNULUS 059 25212-20 % 1 CONT. BLDG. - ELEV. 51'-0 OUTER ANNULUS 059H 25212-20900-SH.59 CONT. BLDG. - ELEV. 51'-0 OUTER ANNULUS 061 25212-20975 MSVB - ELEV. 66'-0 Report: rptZoneDwgRefersnoe y,4 og g Sorted: Zone / Drawing 4.ocation
ZONE DRAWING LOCATION 25212-26814 SH.1 ESF BLDG 25212-26815 SH I ESFBLDG. 25212-26821 SH.1 VARIOUS 25212-26823 SH I MSVB, CONTAINMENT l 25212-26830 SH 2 ESF BLDG. 25212-26830 SH 3,4 MSVB, CONTAINMENT l 25212-26830 SH.2 CONTAINMENT 25212-26833 SH.2 VARIOUS P&ID 25212-26917 SH.1 EDG ENCLOSURE 1 l i t i I i I l Report: rptZoneDwgReference Page8of8 Sorted: Zone / Drawing / Location { l
_ ZONE DRAWING LOCATION 061H 25212-20900-SH.61 MSVB - EEV. 66'-0 062 25212-20976 MSVB - ELEV. 66'-0 062H 25212-20900-SH.62 MSVB - ELEV. 66'-0 063 25212-20977 MSVB - EEV. 66' 0 063H 25212-20900-SH.63 MSVB - ELEV. 66'-0 064 25212-20978 MSVB - EEV. 66'-0 064H 25212-20900-SH.64 MSVB - ELEV. 66'-0 066 25212-20964 CONT. BLDG. - EEV. 24'-0 OUTER ANNULUS 067 25212-20965 CONT, BLDG. - EEV. 24'4 OUTER ANNULUS 668 25212-20 % 6 CONT. BLDG. - ELEV. 54'-0 LOOP D 069 25212-20979 MSVB - ELEV. 44'-6 070 25212-20980 MSVB - ELEV. 44'-6 070H 25212 20900-SH.70 MSVB - ELEV. 44'-6 072H 25212 20900-SH.70 MSVB EEV. 44'-6 073 25212-20983 ESF BLDG. 'A' RHR CUBICLE 079 25212 20971 CONT. BLDG. - ELEV. 3'-8 OUTER ANNULUS 081 25212 20973 CONT. BLDG. - ELEV. 3'-8 OUTER ANNULUS 082 Report: rpt2oneDwgReference Page 5 of 8 Sorted: Zone / Drawing / Location
ZONE DRAWING LOCATION 25212-20974 CONT. BLDG. - ELEV 3'-8 OUIER ANNULUS 083 25212-20860 ESF BLDG. 'A' RHR CUBICLE 083H - 25212-20900-SIL83 ESF BLDG. 'A' RHR CUBICLE 4 096 25212-20873 ESF BLDG. - ELEV. 24'-0 25212-10873 ESF BLDG. - YARD 096H 25212-20900-SH.96 ESF BLDG. - YARD 25212-20900-SH.96 ESF BLDG. - ELEV. 24'-0 097 25212-20874 ESF BLDG. - ELEV. 24'-0 097H 25212-20900-SH.97 ESF BLDG. - ELEV. 24'-0 098 25212-20875 ESF BLDG. - ELEV. 24'4 100 25212-20877 ESF BLDG. 'B' RSS CUBICAL 25212-20877 ESF BLDG. 'B' RSS CUBICLE 100H 25212-20900-SH.100 ESF BLDG. 'B' RSS CUBICAL 102 25212-20879 ESF BLDG. 'A' RSS CUBICLE 113 25212-20890 ESF BLDG. - ELEV. 24'-0 113H 25212-20900-Sil113 ESF BLDG. - ELEV. 24'-0 119 25212-20896 ESF BLDG. - YARD 125 25212-20987 CONT BLDG. - ELEV. 3'-8 LOOP D 25212 20987 CONT. BLDG. - ELEV. 3'-8 OUTER ANNULUS 127 25212-20047 CONT. BLDG. - ELEV. 3'-8 OUTER ANNULUS Report: rptZoneDwgReference Page 6 of 8 Sorted: Zone / Drawing! Location 1
_ -. - _. ~. ZONE DRAWING LOCATION 129 25212-20991 AUX. BLDG. - ELEV. 4' 6 133 25212-20354 AUX. BLDG. - ELEV. 4'-6 .c 136H 25212 20900-SH.136 ESF BLDG. - ELEV.24'-0 144H i 25212 20900 SH.144 ESF BLDG. - ELEV.24'-0 145H 25212-20900-SH.145 ESF BLDG. - ELEV.24' 0 150H 25212-20900-SH.150 CONT. BLDG. - ELEV. 20' 152H 25212-20900-SH.152 FUEL BLDG. - ELEV.24'-0 158H 25212-20900-SH.158 AUX BLDG. - ELEV.24'-0 159H I 25212-20900-SH.159 AUX BLDG. - ELEV.24'-0 167H 25212-20900-SH.167 AUX BLDG. - ELEV.24'-0 168H 25212-20900-SH.168 CONT. BLDG. - ELEV.-10'-0 176H 25212-20900-SH.176 ESF BLDG. - ELEV.12'-0 j 180H 25212-20900-SH.180 AUX. BLDG. - ELEV. 24'-0 183H 25212-20900-SH.183 AUX. BLDG. - ELEV. 24'-0 999 25212-26802 SH 1,2,3 CONTAINMENT 25212-26804 SH 1,2,3,4 AUX. BLDG., CONTAINMENT 25212 26804 SH.2 AUX. BLDG 25212-26811 SH.1 FUEL BLDG. 25212-26812 SH 1 ESF BLDG, CONTAINMENT 25212 26812 SH 1,2 ESF BLDG., CONTAINMENT 25212-26812 SH 3 ESF BLDG. Report: rytZoneDwgReference Fese 7 of 8 u Sorted: Zone /Drewing/ Location}}